1. example use only shielded interface cables when connecting to computer or peripheral devices Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment SA 1965 magnitude to constitute a risk of electric shock to persons The serial number of this product may be found on the bottom of the unit You should note the serial number of this unit in the The exclamation point within an space provided and retain this instruction as a per equilateral triangle is intended to manent record of your purchase to aid identification alert the user to the presence of in the event of theft important operating and mainte nance servicing instructions in the Model No literature accompanying the appli Serial No SA 1966 ance WARNING To reduce the risk of fire or electric shock do not expose this appliance to rain or moisture PREFACE Panasonic s WV BP140 BP142 BP144 series intro duce a new level of high picture quality and high pixels picture elements This model offers cut ting edge technology for advanced video surveil resolution through the use of a 1 3 inch interline lance transfer CCD image sensor having 510 horizontal 1 The following functions are built in 3 Minimum illumination of 0 08 lux 0 008 foot 1 Auto Light Control ALC Electronic Light Control ELC candle with F1 4
2. 1 It is recommended to use a monitor whose resolution is at least equal to that of the camera 2 The maximum extensible coaxial cable length between the camera and the moni tor is shown below Type of RG 59 U RG 6U RG 11 U RG 15 U coaxial cable 3C 2V 5C 2V 7C 2V 10C 2V Recommended m 250 500 600 800 maximum cable length ft 825 1650 1980 2 640 FOCUS OR FLANGE BACK ADJUSTMENT The following adjustment should be made by qualified service personnel or system installers Loosen the screw on the side of the camera Focusing of Focusing of ee A C mount lens og Focus Fixing Screw Flange back Adjusting Ring Installation of Auto Iris Lens Connector Install the lens connector YFE4191J100 when using a video drive ALC lens The installation should be made by qualified service personnel or system installers Cut the iris control cable at the edge of the lens connector to remove the existing lens connector and then remove the outer cable cover of the sup plied connector as shown in the diagram The pin assignment of the lens connector is as fol lows Pin 1 Power source 9 V DC 50 mA max Pin 2 Not used Pin 3 Video signal 1 3 V p p 40 KQ Pin 4 Shield ground Rib Pin 3 Pin 1 Pin 4 Pin 2 Solder the lens cable to the pins of the sup plied connector Mounting the Lens Caution Before you mount the lens loosen the screw on the s
3. Panasonic CCTV Cameras Operating Instructions vono WV BP140 WV BP142 WV BP144 Before attempting to connect or operate this product please read these instructions carefully and save this manual for future use Lens Option N0301 0 V8QA5750AN we in Japan 19 For U S A NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environ ment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manu al may cause harmful interference to radio com munications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER OR BACK NO USER SERVICEABLE PARTS INSIDE REFER SER VICING TO QUALIFIED SERVICE PERSONNEL The lightning flash with arrowhead FCC Caution To assure continued compliance symbol within an equilateral trian gle is intended to alert the user to the presence of uninsulated dan gerous voltage within the product s enclosure that may be of sufficient
4. Corporation of America Executive Office One Panasonic Way 3E 7 Secaucus New Jersey 07094 Regional Offices Northeast One Panasonic Way Secaucus NJ 07094 201 348 7303 Southern 1225 Northbrook Parkway Suite 1 160 Suwanee GA 30024 770 338 6838 Midwest 1707 North Randall Road Elgin IL 60123 847 468 5211 Western 6550 Katella Ave Cypress CA 90630 714 373 7840 Panasonic Canada Inc 5770 Ambler Drive Mississauga Ontario L4W 2T3 Canada 905 624 5010 Panasonic Sales Company Division of Matsushita Electric of Puerto Rico Inc Ave 65 de Infanteria Km 9 5 San Gabriel Industrial Park Carolina Puerto Rico 00985 809 750 4300 2001 Matsushita Communication Industrial Co Ltd All rights reserved
5. a top mounting type is also available To mount from the top remove the mount adapter from the bottom of the camera by removing two fixing screws Attach the mount adapter to the top as shown in the diagram then mount the camera on the mounting bracket Make sure that two original screws are used when mounting the mount adapter longer type screws may damage inner components too shorter type screws may cause the camera drop Focus Fixing Screw Power Cord only for WV BP140 Connect this power cord to an electrical out let of 120 V AC 60 Hz DC 12 V Input Terminal DC 12V IN only for WV BP142 This terminal is for connecting the 12 V DC power supply cord AC 24 V Input Terminal AC 24V IN only for WV BP144 This terminal is for connecting the 24 V AC 60Hz power supply cord Automatic Light Control Electronic Light Control Selector ALC ELC Lets you select the mode according to the lens type used ALC Select this mode when an auto iris lens ALC lens is used with this camera ELC Select this mode when a fixed iris lens or manual iris lens is used with this cam era Back Light Compensation Mode Selector BLC ON OFF ALC ELC Lets you select BLC ON or OFF according to the position of the object and light conditions on the screen Camera Mounting Screw Holes f nasonic n w BP144 g Fixing Screws Mount Adapter BLC ON Select this mode
6. lens tissue or a cotton tipped applicator and ethanol Never face the camera towards the sun Do not aim the camera at bright objects Whether the camera is in use or not never aim it at the sun or other extremely bright objects Otherwise blooming or smear may be caused Do not operate the camera beyond the specified temperature humidity or power source ratings Use the camera under conditions where tem perature is between 10 C 50 C 14 F 122 F and humidity is below 90 The input power source is 120 V AC 60 Hz for WV BP140 12 V DC for WV BP142 and 24 V AC 60 Hz for WV BP144 Caution To prevent fire or electric shock hazard use a UL listed cable VW 1 style 1007 for the DC 12 Vor AC 24 V Input Terminal MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS lt WV BP140 gt G gt 6 12 ELIA BLC ON 8 BIS ELC ALC p VIDEO ALC DC ELC 4 OFF O lt WV BP142 gt DOIN IN i 8 wD Auto Iris Lens Connector Supplies power and control signals to an auto iris lens not supplied Flange back Adjusting Ring This ring adjusts the back focal distance or picture focus Rotate this ring clockwise for a C mount lens or counterclockwise for a CS mount lens Lens option Mount Adapter The camera mounting screw hole is for mounting the camera onto a mounting brack et The camera is originally designed to be mounted from the bottom however
7. lenses 2 Back Light Compensation 4 Horizontal resolution of 380 lines 3 Line locked Sync or Multiplexed Vertical Drive VD2 only for WV BP140 and WV 5 Shooting of indoor scenes with fixed iris lens BP144 Internal Sync or VD2 only for WV BP142 2 Signal to noise ratio of 46 dB PRECAUTIONS 1 4 Equivalent to AGC Off Do not attempt to disassemble the camera To prevent electric shock do not remove screws or covers There are no user serviceable parts inside Ask a qualified service person for servicing 2 Handle the camera with care Do not abuse the camera Avoid striking shaking etc The camera could be damaged by improper handling or storage 3 Do not expose the camera to rain or moisture or try to operate it in wet areas Turn the power off immediately and ask a qualified service person for servicing Moisture can damage the camera and also create the danger of electric shock by use of Electronic Light Control ELC func tion Selectable auto iris control signal for the lens from a video signal or DC control signal Do not use strong or abrasive detergents when cleaning the camera body Use a dry cloth to clean the camera when dirty In case the dirt is hard to remove use a mild detergent and wipe gently Afterwards wipe off the remained part of the detergent in it with a dry cloth Clean the CCD faceplate with care Do not clean the CCD with strong or abrasive detergents Use
8. when a strong light such as a spot light is in the back ground OFF Normal picture 1 Confirm the position of the lens type and the lens drive signal selector 2 If you have selected ALC use the selec tor ALC to select the mode If ELC is selected select the mode by selector ELC Caution To use in ALC mode make sure to set the selector ELC to OFF position To use in ELC mode make sure to set the selector ALC to OFF position Lens Drive Signal Selector VIDEO DC Lets you select the mode according to the type of auto iris lens drive signal to be supplied to the lens from the auto iris lens connector VIDEO Select this mode if you are using the auto iris lens that requires a video drive signal DC Select this mode if you are using the auto iris lens that requires a DC drive signal 2 Video Output Connector VIDEO OUT This connector is for connecting with the VIDEO IN connector of the video monitor Whenever the multiplexed vertical drive VD2 signal is supplied to this connector the cam era synchronization mode is automatically set to Vertical Drive Cautions Connect to 12 V DC 10 5 V 16 V or 24 V AC 19 5 V 28 V class 2 power supply only Make sure to connect the grounding lead to the GND terminal when the power is sup plied from a 24 V AC power source To prevent fire or electric shock hazard use a UL listed cable VW 1 style 1007 for the DC 12 Vor AC 24 V Input Termin
9. al CONNECTIONS A WV BP140 120 V AC 60 Hz Connect the power cord to an electrical outlet of 120V AC 60Hz B WV BP142 12 V DC Connect the power cord to the DC 12V IN ter minal on the rear panel of the WV BP142 OC 12V N K ore D 12 VDC 10 5 V 16 V Resistance of copper wire at 20 C 68 F Copper wire 24 22 20 18 size AWG 0 22mm 0 33mm 0 52mm 0 83mm Resistance 0 078 0 050 0 08 0 018 Resistance 9 026 0 017 ooro 0 006 e Calculation of maximum cable length between camera and power supply 10 5V DC lt Va Rx 0 42 x L lt 16 VDC L Cable length meters R Resistance of copper wire Q meter Va DC output voltage of power supply unit Va 12 L standard 342x R meters ax Va 16 L minimum 042xR meters Va 10 5 L maximum J42xR meters C WV BP144 24 V AC 60 H2 Connect the power cable to the AC 24V IN terminal on the rear panel of the WV BP144 AC 24V N 24 V AC 60 Hz 19 5 V 28 V Recommended wire gauge sizes for 24 V AC line Copper wire 24 22 20 18 size AWG 0 22 mm 0 33 mm 0 52 mm 0 83 mm Length m 95 150 255 425 of Cable Approx ft 314 495 842 1403 Caution To prevent fire or electric shock hazard use a UL listed cable VW 1 style 1007 for the DC 12 V or AC 24 V Input Terminal Video Cable
10. erating Humidity Power Source and Power Consumption Dimensions without lens Weights without lens 510 H x 492 V pixels Interline Transfer CCD 4 8 H x 3 6 V mm Equivalent to scanning area of 1 3 pick up tube WV BP140 and WV BP144 Line locked or Multiplexed Vertical Drive VD2 selectable WV BP142 Internal or Multiplexed Vertical Drive VD2 selectable 2 1 interlace 525 lines 60 fields 30 frames 15 75 kHz 60 00 Hz 380 lines 1 0 V p p NTSC composite 75 Q BNC connector 46 dB Equivalent to AGC Off weight On Equivalent to continuous variable shutter speed between 1 60 s and 1 120 000 s DC or Video selectable 0 08 Ix 0 008 foot candle at F1 4 C mount or CS mount selectable 10 C 50 14 F 122 F Less than 90 WV BP140 120 V AC 60 Hz 2 3 W WV BP142 12 VDC 175 mA WV BP144 24 V AC 60 Hz 2 1 W 67 mm W x 65 mm H x 123 mm D 2 5 8 W x 2 9 16 H x 4 13 16 D WV BP140 0 45 kg 0 99 Ibs WV BP142 0 3 kg 0 66 Ibs WV BP144 0 32 kg 0 71 lbs Weights and dimensions indicated are approximate Specifications are subject to change without notice STANDARD ACCESSORIES OPTIONAL ACCESSORIES Lenses WV LA2R8C3B WV LA4R5C3B WV LA9C3B WV LA210C3 WV LA408C3 WV LA908C3 WV LZ61 10 WV LZ62 2 WV LZ62 8 WV LF4R5C3A WV LF9C3A WV LFY3C3 WV LFY45C3 WV LFY9C3 Panasonic Security and Digital Imaging Company A Division of Matsushita Electric
11. ide of the camera and rotate the flange back adjusting ring clockwise until it stops If the ring is not at the end the inner lens or CCD image sensor may be damaged Mount the lens by turning it clockwise on the lens mount of the camera Connect the lens cable to the auto iris lens connector on the side of the camera Focus Fixing Screw Caution for Mounting the Lens The lens mount should be a C mount or CS mount 1 32UN and the lens weight should be less than 450 g 0 99 lbs If the lens is heavier both the lens and camera should be secured by using the supporter The protrusion at the rear of the lens should be as shown in the diagram C mount Less than 13 mm 1 2 CS mount Less than 8 mm 5 16 Turn the flange back adjusting ring to the desired position Caution When the C mount lens is mounted do not rotate the ring counterclockwise by force after it stops If the ring is rotat ed by force the inner lens or CCD image sensor may be damaged Tighten the screw on the side of the camera Caution Tightening the screw by force will cause damage to the screw or deviation of focus SPECIFICATIONS Pick up Device Scanning Area Synchronization Scanning System Scanning Horizontal Vertical Horizontal Resolution Video Output Signal to Noise Ratio Electronic Light Control Lens Drive Minimum Illumination Lens Mount Ambient Operating Temperature Ambient Op