1.   The entire test  including all right and left side repetitions   will be deleted     COO OHO OOD       Reviewing an Exam    An exam can be reviewed at any time  either during testing or after  by  pressing the    REVIEW    button  The last completed repetition will be dis   played  To review other tests within the exam  press    NEXT    to advance  to the next test with recorded data  When advancing through tests  the  Commander display shows the test number with the right side repetition   To see left side repetitions and additional statistics press    REVIEW        COG    Statistics    To scroll through and review all the statistics for the displayed test  continue press   ing    REVIEW        In the following example  the statistics for test 4 are displayed in the order they will  appear by pressing    REVIEW     For this example  the number of repetitions was  set at two     TEST uf REVIEW  REP   RIGHT    JIU         gt   Ab O AS    Maximum Force  Repetition 1 Right Side    TEST Lf REVIEW  RIGHT      te    CV Right Side    TEST bf REVIEW  REP 2 LEFT    IOT l  OL             TEST S  REVIEW  REP 2 RIGHT    JUL     o A       Maximum Force  Repetition 2 Right Side    TEST Lf REVIEW  REP    LEFT    JIi  LULI    Maximum Force  Repetition 1 Left Side    TEST Lf REVIEW  LEFT    ay   it  ess       Statistics Definitions    LBS  In    Test    and    Test Alt    modes  LBS displays force against the dynamome   ter in real time  In    Review    mode  LBS shows maximum force on  dyn
2.   This button changes the parameter setting     TEST ALT     Press this button until console  is in    Setup    mode  After  parameters are set  use this  button to exit back to    Test     mode     While in    Setup    mode  use  this button to advance through  parameters     THRESHOLD    Bunce When a parameter is displayed   use this button to change the  default setting     Adjustable Defaults    The PowerTrack II Commander console allows you to control the following default  parameters     THRESHOLD  This setting determines the amount of force that must be exerted  against the dynamometer before the console begins recording data  This setting is  used to avoid inadvertently beginning a test  It can be set at 1  3  5  10 or 20  pounds     TEST  Controls the number of tests available for an exam  The console automati   cally goes into    Review    mode when the number is reached  It can be set from 5   40 in increments of five    REP  Sets the number of repetitions per side per test  It can be set from 1 4  A  minimum of two repetitions is required for CV calculations     LBS  N   This parameter controls whether force readings are in pounds or newtons     Test and Test Alt Modes    Tests are conducted using either the    Test    or    Test Alt    modes   How the modes  are used is described below      To conduct a test  apply pressure on the dynamometer  Test recording begins when  the default threshold force is exceeded  A test ends when force on the dynamome   ter drops b
3.  receptacle  When installing a cord  make sure the jack    snaps    securely  into place     NOTE  Jf a cord is damaged or lost  do not attempt to replace with a standard tele   phone cord as the wiring is not the same  Contact JTech Customer Service for the  correct replacement cord     Using the Commander Console    Conventions    This manual adopts the following convention throughout     Test Refers to one strength assessment that may include multiple repetitions  and comparisons between the right and left side  For instance  testing  elbow flexion with three repetitions for the right side and three repetitions  for the left side is one test     Exam Refers to multiple tests  For example  testing elbow flexion  elbow exten   sion  wrist flexion  and wrist extension could comprise one exam     On Off Button    Press the    ON OFF    button once to turn the console on  press it again to  turn the console off  Exams stored in memory are not erased when power  is turned off  Holding the    ON OFF    button down for two seconds clears    all stored exams  The console shuts off automatically after four minutes of  inactivity     Note  Make sure no force is applied to the dynamometer when turning the console on     When the console unit is turned on it will activate in either    Test    mode or     Review    mode  depending on whether an exam is stored in memory  If no exam  is stored in memory the console will activate in Test mode ready for test  1     The active    mode     in
4.  this case    TEST     is displayed in this area     Test and repetition numbers are  shown here     Side being tested is displayed on  this line     Real time force on dynamometer  can be shown in pounds or newtons        Testing Mode       If an exam is in memory when the console is turned on  Commander activates in     Review    mode  From this point you can review exam data  change to    Test    mode  to finish testing  or delete the exam     Setup Mode  Testing Defaults    The Commander console enables you to use the    Setup    mode to control a variety  of test parameters  such as the testing threshold  number of tests  number of repeti   tions per test  and force readings in pounds or newtons  Once test parameters are   set  they become the defaults for the console  For example  if you set the number of  repetitions to three  then the unit will test for three repetitions per side for every  exam  unless you change the default  Default settings do not change when the unit  is turned off or when an exam is deleted  Defaults can only be reset manually     Setting Defaults    Three buttons are used when setting console defaults  TEST CONT   SETUP    NEXT  SELECT  and REVIEW  CHANGE   The buttons function as follows     TEST CONT   SETUP   Press this button to move through the console modes until     Setup    is displayed  It is also used to exit    Setup    after setting parameters     NEXT  SELECT   Use this button to advance through the test parameters   REVIEW  CHANGE 
5. Powerfrack ii       COMMANDER    User   s Manual    Written by  Tracy Livingston  David Bernardi  and Michael Carroll    Published by  JTech Medical Industries  4314 ZEVEX Park Lane  Salt Lake City  UT 84123   801 264 1001   www jtechmed com    AMITECH    a ZEVEX company    Copyright    1997 JTech Medical Industries   All rights reserved   PN 680    Contents    Register Your Commander             00 000 erea 1  Commander Warranty            0 0 ccc cece eenee 1  To have your Commander or PowerTrack II repaired                     1  Features and Benefits         0 0 0    c cece nen 2  Ch    ck Your System csr erei Ged seg Ened PEEN EEEE EERE pede hie wee es 3  Proper Care sanne en e E EE A E E E e OS ES 3  Calibration  dpisca eas yuet a eaa a Sas a E a tak 3  Battery Lifes    on3 conta es Oh dewu e a Seas T 3  Available Upgrades       0 0    eee eens 4  Wrist and Desktop Use of the Console                0 0 c eee eee 4    Using the Commander Console    Conventions  s 4 eck 64 ow de ee Chee eee OEE eee aS 5  On Off Butto  5  lt  0 0530 24 R4 ee ses haba or oy ta ES ee ees ee eee 5  Setup Modesa et Seta aen e gue ny acetone ue aussie ate aad ERNAS Matas RUTE act cee  6  Test and Test Alt Modes          0 0    0c cette nee 7     Testing Methods  25  c  4   4 esere mres bea oe Cae we ee ba ea a wees 8  Advanced Console Features          0 0 0 c cece eee 10  Reviewing an Exam    1    eee ee eens 10  Statistics Definitions   2000    0 0    ccc eee eens 12  Deleting an Exam ssc 5  
6. a weakness in several muscles may further substantiate  disease or injury involving nerve roots or peripheral nerves  as long as disuse or  disease of the fibers of the muscle or disorders of the higher levels of the central  nervous system are ruled out     Manual muscle testing should never be used alone to diagnose  but should be used  in conjunction with other diagnostic testing tools such as the Dualer dual inclinom   etry system or Commander Algometer pain pressure testing  If a rehabilitation pro   gram is initiated  bilateral manual muscle testing should be completed at periodic  intervals along with other diagnostic testing to document treatment efficacy     Manual Muscle Testing Accuracy    General rules must be followed to insure repeatability and accuracy when using the  PowerTrack II manual muscle tester     1  If testing bilaterally  the muscles and or tendons that normally cause the motion  should be palpated bilaterally to help identify substitution by muscles other than  the prime movers  Adjust patient stabilization or position until substitution is  eliminated  If substitution continues  document the nature of the substitution     2  The lever arm length between the attachment point of the muscle and the  PowerTrack II dynamometer must be the same between repetitions and sessions   Make sure the unit is placed at the same location for each repetition and test   For multiple repetitions  better accuracy is achieved if the unit remains placed  on the body dur
7. ack below the threshold  The display then indexes to the next repetition  in the series  After all repetitions for a test are completed  the display indexes to  the next sequential test number  Continue testing with this method until all tests are  recorded in memory     Repetitions for a Test    The Commander console can record up to four strength repetitions per side for each  test  The repetition order is selected by either of two methods     Same Side Repetition Order  When    Test    mode is displayed  the unit prompts  for all right side repetitions first  then all left side repetitions     For example  if the default is two repetitions  the test sequence in    Test    mode is     TEST 1 REP 1 RIGHT  TEST 1 REP 2 RIGHT    TEST 1 REP 1 LEFT  TEST 1 REP 2 LEFT    TEST 2 REP 1 RIGHT  TEST 2 REP 2 RIGHT _    etc     Helpful Hint  If unilateral testing is required  the right side can be tested and the  left side skipped by pressing the    NEXT    button  or the right side can be skipped  by pressing    NEXT    and testing the left side     Alternating Sides Repetition Order  When    Test Alt    mode is displayed  the rep   etitions alternate between right and left side as follows     TEST 1 REP 1 RIGHT  TEST 1 REP 1 LEFT    TEST 1 REP 2 RIGHT  TEST 1 REP 2 LEFT    TEST 2 REP 1 RIGHT  TEST 2 REP 1 LEFT    Etc     This method can be used if submaximal effort is indicated  By mixing up the left  and right side routine  the subject may have a more difficult time repeating the  r
8. amometer for the displayed repetition       CV  The coefficient of variation for all the repetitions for the indicated side  using the n 1 method          Deficit  Bilateral deficit indicating weakness of one side compared to the other     Deleting an Exam    To erase an exam  turn the Commander console on  then press and hold the     ON OFF    button for a minimum of two seconds  or until the unit reactivates   When the button is pressed unit console will beep and turn off indicating data has  been erased     Note  All test default values will be retained     Reports    Muscle testing reports from PowerTrack II Commander can be created several  ways     1  Use the supplied worksheets to create hard copy documentation     2  Optional Easy Docs Plus Software from JTech Medical is an efficient way to  generate reports using your PC  With Easy Docs Plus you enter muscle testing  data into the software using your keyboard  Easy Docs Plus then maintains the  data  calculates statistics  produces progress bar graphs  generates data reports  and allows you to print narratives from Microsoft Word      o 1D Yio Yro       Maximum Force CV Left Side  Repetition 2 Left Side  TEST Lf REVIEW   Bilateral Deficit  Left Side  LEFT      DEFICIT  After all statistics have been selected  the dis     aa play circles back to the beginning       Selecting the next test to review  To view the  ZN next test  press    NEXT     The display indexes    only to test numbers with data        m      The Pow
9. an quickly and easily create cutting edge data and narra   tive reports     Tracker    Upgrade Package  PowerTrack II comes ready to plug into the leading  Windows based musculoskeletal evaluation software package  The upgrade package  includes the Tracker Interface Box    for connecting to a PC  The PowerTrack II     dynamometer plugs into the PowerTrack II port of the Tracker Interface Box     without any modifications  Tracker    software automatically records test results  with real time force curves  analyzes statistics  charts comparisons to previous tests   works seamlessly with other Tracker diagnostic devices  and outputs data in a com   prehensive report format  With the optional Tracker Impairment Software  the sys   tem automatically calculates motor deficit impairments from muscle testing results     For more information on upgrades  contact your JTech sales representative or call  JTech at 1 800 985 8324 or 1 801 264 1001     Wrist and Desktop Use of the Console    The PowerTrack II Commander system comes equipped with two cords for con   necting the dynamometer to the console unit  The short cord is used when the  Commander console is strapped to the examiner   s forearm  The longer cord is used  when the Commander console is placed on a desktop or left in the case during test   ing    The cords connect to the console and dynamometer with telephone jack plugs  To  remove a cord  press down on the cord jack   s plastic release lever and slide the end  out of the
10. and to meet specifications  In spite of diligence in manufacturing  eliminating malfunc   tions resulting from random component failure is impossible  Therefore  JTech will at its  option repair or replace the product with a new or reconditioned unit at no charge for a peri   od of one year from the date of purchase     In view of the varied conditions in which the unit will be used  the Commander Console and  PowerTrack II are sold    as is    and JTech   s responsibility does not go beyond the terms set  forth above  JTech will not be responsible for medical expenses or any direct  indirect  or  consequential damages arising from the use of this product  JTech shall in no way be liable  loss of revenue or profits resulting or alleged to result from use of this product     THIS WARRANTY IS MADE EXPRESSLY IN LIEU OF ANY OTHER WARRANTY   EXPRESS OR IMPLIED  INCLUDING AN IMPLIED WARRANTY OF MER   CHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE  UNDER NO CIR   CUMSTANCES SHALL JTECH BE LIABLE FOR ANY DIRECT  INDIRECT  INCI   DENTAL  OR CONSEQUENTIAL DAMAGES  THE REMEDIES SET FORTH IN  THIS WARRANTY SHALL BE THE ONLY REMEDIES AVAILABLE  EXCEPT AS  SPECIFICALLY PROVIDED BY STATE LAW  NO PERSON HAS ANY AUTHORITY  TO BIND JTECH TO ANY REPRESENTATION OR WARRANTY EXCEPT AS SPECIF   ICALLY SET FORTH HEREIN     To have your Commander or PowerTrack II repaired     1  Contact JTech Customer Service and describe the problem  After receiving a  return authorization number  return the produ
11. ce0a0 bassins prae pee dee ees eee gals wae Sees 12  Repons enepar a a ay EEE nee ac cada ataam aug O nee E EE EF 12    The PowerTrack IT Dynamometer    Care and  Cleaning     32 55 535  ocak otae codec unde taba dee debe bie 13  Changing Testing Pads         0 0    0c teens 13  Using the Dynamometer     0 0 0    2  eee tees 13    Manual Muscle Testing  General Considerations    Manual Muscle Testing Precautions           0 0    eee eee eee eee 14  Manual Muscle Testing   General Information                  0 005  14  Manual Muscle Testing Accuracy           0    c eee ee eee 14    Grading Muscle Tests    When Should a Muscle Test Be Graded               000 0 c eee eee 15  Grading with the Muscle Testing Dynamometer                    005  15  Grading without the Muscle Testing Dynamometer                      16    Register Your Commander    Please register your Commander products so we can provide you with easy access  to our friendly customer service department  Registering your device will also  guarantee that you will be fully covered under your warranty     Registration also provides you with these extra benefits     New product upgrades   New product announcements   Seminar announcements     Special offers   For your convenience  a registration card is included with your order  Simply fill it  out and return it to JTech     Commander Warranty    One year Limited Warranty    The Commander    console and PowerTrack II    dynamometer are designed to perform reli   ably 
12. ct to JTech  including all acces   sories  postage paid and insured to JTech  JTech is not responsible for dam   ages or losses incurred in shipping     2  Submit proof of purchase and date     3  Include a brief explanation describing the problem     Features and Benefits    PowerTrack II    Dynamometer   e Produces very stable make or break tests        Reduces    roll over    and tilting with a 1 8    high ergonomic design that fits in  the palm     TM    e Uses snap in place Quick Connect    system for changing accessory pads   which is much faster than old fashion screw on methods     e Maintains accuracy even when force is applied off center with exclusive Axis  Compensation       smart    load cell     e Guarantees 99  force accuracy over the entire test pad area  compared to  other products with off center force accuracy from 94 96   Call JTech for  accuracy report details     e Includes both round and curved test pads   Commander    Console   e Easy to read 2    diagonal LCD     e Operates during exams either as a wrist unit or as a desktop system when using  the included longer cable     e Gathers  stores  and analyzes up to 40 bilateral muscle strength tests  including  up to four repetitions per side     e Calculates CV and maximum force for each repetition      Documents outcomes assessment with the automatic bilateral deficit analysis     e Helps determine consistency of effort in workers compensation and FCE  exams     e Test now  record later because the exam 
13. eficit greater than 15  exists bilaterally when tested with the  dynamometer  the weaker side should be assigned a grade 4  As noted earlier  a  grade is required if the test is to be included in an impairment report  Grading  may be skipped if all that is needed is the bilateral strength comparison for  showing progress  justifying treatment  or determining the injured diseased  nerves     Grading without the Muscle Testing Dynamometer    If the subject does not have sufficient strength to resist against the force gauge or a  force gauge test is infeasible  then the following grading system can be used     Grade 4 5   Good Normal  Moderate to full resistance against the examiner   Grade 3   Fair  Partial to complete motion against gravity   Grade 2   Poor  Partial to complete motion with gravity removed     Grade 0 1  Zero Trace  No contraction to slight contraction     
14. erTrack If Dynamometer    Care and Cleaning    PowerTrack II is an electronic device and  therefore  should not be submerged in  liquid or placed in an autoclave  The device should be cleaned with a soft  non   abrasive cloth dampened with clean water  Do not use solvents  detergents or  harsh disinfectant on the PowerTrack   s plastic body     Testing pads should be removed from the device for cleaning  Pads can be cleaned  with a mild  non abrasive detergent and a soft cloth  The metal connecting rod  should be dried thoroughly after the pad is cleaned     When not in use the device should be stored in the case provided  Avoid dropping  or banging the device against hard objects  Never stand on  pound with or apply  more the 125 lb  of pressure against the dynamometer     Changing Testing Pads    PowerTrack II features a    quick release    system to make changing testing pads fast  and easy     To remove a testing pad  grasp the pad with your thumb and index finger at the  notches in the dynamometer so your fingers can pull against the underside of the  pad  Pull the pad straight out from the dynamometer     To install a testing pad  insert the metal post into the dynamometer receptacle and  press the pad all the way in  Make sure pad is securely in place against load cell  before beginning a test     Using the Dynamometer    PowerTrack II was designed to fit comfortably in the palm of your hand during  manual muscle testing  It can be used to test with either hand  Its sl
15. esults on each side as indicated by the coefficient of variation     Testing Methods    The Commander console can store up to 40 tests in memory complete with data for  all repetitions and statistics  In order to easily record multiple tests the Commander  uses Automatic Indexing     This method automatically indexes the display to the  next test in the series without requiring you to press any buttons  For example   after completion of all right and left side repetitions of test 1  the display indexes to  TEST 2 REP 1 RIGHT     NOTE  After completing a test  Commander prevents inadvertent deletion of tests  previously stored in memory by indexing to the next test not completed  For  example  if test 2 was completed previously  after test 1 is completed Commander  will skip test 2 and index to test 3     Sequential Testing Method    This method always begins with test 1 using Automatic Indexing    to proceed from  test 1 to test 2  etc  Mark the muscle groups on the exam worksheet with the corre   sponding test numbers from the display     For example  a muscle testing exam is com  TEST Z TEST   pleted in the following order  elbow flexion  RIGHT  elbow extension and shoulder abduction   Before starting the exam     1    is placed on  the elbow flexion line of the worksheet     2     on elbow extension and    3    on shoulder  abduction  Then either during the test or  after  test data for the test number on the  Commander unit is recorded on correspond   ing line of the work
16. ext automat   ic test in the series  If you inadvertently begin a test at the next test number instead  of the worksheet number because of Automatic Indexing     delete the test by press   ing    REVIEW    and holding it while you press    Redo         L     Advanced Console Features    Press    REDO    to test the last repetition again  This feature is helpful if  the current test was started inadvertently  was done incorrectly or was for  practice     Redo a test   If after reviewing exam results  you determine that a test  all  right and left repetitions  needs to be redone  press    REVIEW     Once in     Review    mode  press    NEXT    until the correct test number is displayed   Press and hold    REVIEW    and press    REDO     Repeat the test     Important Note  When using    REDO    for a test  the entire test  including  repetitions for the right and left side  are deleted and must be redone     Review last repetition   To review the measured force for the last repeti   tion  press    REVIEW    after the repetition is complete  To review other  statistics associated with the test  continue pressing    REVIEW     and the  display will scroll through all available statistics  To continue testing with  the next repetition  press    TEST CONT     To erase the repetition and start  over  press    REDO        Deleting a test   Press    REVIEW    then press    NEXT    until the correct  test number is displayed  While holding the    REVIEW    button down   press    Redo   
17. g systems  the actual force values are automatically recorded  so the  need to grade every test is greatly reduced  As a result  tests conducted for purpos   es like initial screenings and monitoring progress are not required to be graded  In  addition  tests not graded during the examination  or immediately after  can be grad   ed at a later date if necessary using the test values recorded on the worksheet     According to the AMA Guides to the Evaluation of Permanent Impairment  a mus   cle test must be graded if it is to be used as part of an impairment rating  Tests  where the patient cannot exert force against the dynamometer or where the use of a  force gauge is infeasible should also be graded to provide documentation of the test     Grading with the Muscle Testing Dynamometer    Grade 4 or 5     These grades are assigned if the patient can provide slight to full resistance against  the dynamometer     1  Patient moderately resists against the examiner  If any resistance occurs  then  the patient has enough strength to provide resistance against the muscle testing  dynamometer  If the patient is too weak to provide any resistance  grades 0 1   2  or 3 should be assigned based on test results obtained without using the  dynamometer     2  Place the patient in the recommended position and conduct a test using the  dynamometer  Repeat for a minimum of three repetitions to ensure accuracy  and repeatability     3  Repeat the test for the opposite side     4  Ifa strength d
18. im profile  helps reduce the    roll over    effect that can occur with taller dynamometers   However  PowerTrack II should always be used with your hand under the strap     The testing pads should be selected according to the surface area where the  dynamometer will be placed  When placing the dynamometer against the forehead  for a cervical flexion test  the flat pad should be used  Likewise  when the  dynamometer is placed against a curved bony area  such as the forearm  the curved  pad should be used  The curved pad can also be rotated in the load cell to provide  the greatest patient comfort during a test     Manual Muscle Testing   General Considerations    Manual Muscle Testing Precautions    The following are general guidelines to minimize risk of injury to the patient   Please note that these guidelines are not comprehensive because covering all possi   ble conditions would be impossible  Therefore  final responsibility for the risk of  injury to the patient lies with the examiner     1  Force increase should be gradual     2  Patient should be CLOSELY observed for any evidence of pain  The test should  be stopped immediately if this occurs     Manual Muscle Testing   General Information    Manual muscle testing or grading should be performed when neurological problems  at the nerve root or peripheral nerve are suspected  or if disease or disuse affects the  muscles  Manual muscle testing can help identify specific nerve motor function   Bilateral testing indicating 
19. ing all repetitions     3  Ensure the starting point for breaking action is at the same range of motion  position for each test and repetition  This is necessary because of the wide vari   ations in force the prime movers can oppose depending on the starting point of  breaking action     4  Determine the plane of motion of the segment and ensure that the PowerTrack II  dynamometer is not sideways or off axis to this motion  Additionally  apply  force in the direction of motion     5  Always build up resistance smoothly until the position is broken  In general the  break should occur within 2 3 seconds  Prolonging the time to break may intro   duce fatigue  Shorter breaks are at higher risk of re injury or may not allow for  buildup of maximum contraction  For difficult to break segments  two hands  may be required     Grading Muscle Tests    Traditionally  muscle testing uses a grading system for documentation and standard   ization  In the traditional system muscle test grades range from 4 5    Good Normal     to 0 1    None Slight Contraction     With the introduction of the PowerTrack II man   ual muscle tester and the JTech   s IsoTrack isometric testing station  the system has  been modified slightly to encompass the additional diagnostic data available     When Should a Muscle Test Be Graded     Using the traditional subjective method of muscle testing  every test needed to be  graded just for the purpose of documentation  With Commander   s PowerTrack II  muscle testin
20. is stored in memory  even when  Commander is turned off     e Automatic audio prompts examiner for the next test in the series   e Measures up to 125 pounds for very strong performers   e Battery powered for portable operation     e Test protocols can be customized according to number of tests  starting force   newtons pounds and number of repetitions     Check Your System    Your PowerTrack II Commander system should include the following parts       Commander Wrist Unit   Round Pad    PowerTrack IT Dynamometer   Curved Pad     Short Cord   Testing Chart    Long Cord   Worksheets    Make sure the serial number on the PowerTrack II  located under the testing pad   matches the serial number on the Commander Console  If these numbers do not  match  call JTech Customer Service     Proper Care    With proper care your new PowerTrack II Commander will provide many years of  worry free use  Do not immerse the dynamometer or the console in water  place in  an autoclave or sterilize with harsh disinfectant To clean the housings  wipe with a  soft  non abrasive cloth moistened with clean water  To clean the display  use a  non abrasive dry cloth  Do not use cleaners  Avoid dropping or banging the instru   ment or console against hard objects  Do not stand on  apply more than 125 Ib  or  use the dynamometer for anything other than manual muscle testing  Failure to fol   low these policies will void the warranty     Calibration    To ensure accuracy the PowerTrack II and Commander conso
21. le have been factory  calibrated with weights traceable to the National Institute of Standards and  Technology  When turned on the Commander console automatically zero calibrates  itself  Therefore  make sure the dynamometer test pad is turned up and no force is  being applied when the Commander console is turned on  Any force applied to the  dynamometer when the console is turned on will become the zero value and will  result in inaccurate force readings     Battery Life    The Commander console uses a standard 9 volt alkaline battery  The estimated bat   tery life is 28 hours of operation  The Commander console should always be turned  off when not in use to maximize battery life   The console will automatically shut  itself off after four minutes of inactivity   NiCad batteries can be used  however   the active battery life will be reduced to approximately eight hours or less  When  using a NiCad battery  completely drain the battery before recharging to prevent     memory    in the battery that will further reduce battery life     Available Upgrades    The PowerTrack II    can be used with the following upgrade products     Easy Docs Plus Software   Transfer Commander test data to you PC with this key   board entry software  Easy Docs Plus Software maintains your test data  along with  additional patient data  test data from other devices  such as inclinometers   goniometers  and static lift gauges  and results from your favorite questionnaires   With Easy Docs Plus you c
22. sheet  This method facili        tates documentation during exams by allow   ing you or staff to complete the worksheet  after the exam is finished     In this example  test 2 would corre   spond to elbow extension on the  worksheet     Helpful Hint  Since the display indexes past old tests stored in memory  this  method is recommended only if all previous tests have been erased     Assigned Testing Method    This method uses the default test numbers assigned to the test on the worksheet and  flip chart  The assigned numbers on the worksheet and chart correspond to the test  numbers selected on the Commander console  Therefore  Automatic Indexing     should not used with this method  Instead  use the    NEXT    button to select the test  number on the Commander unit that correspond to the test number on the work   sheet or chart     TEST Pa TEST  REP  lt  RIGHT   Neck Flexion          3 Neck AL Flexion  4 Shoulder Flexion    In this example  the test number on the display corresponds  to the pre printed test number on the worksheet     This method eliminates the necessity of writing the test number on the worksheet  before or during the exam as with the Sequential Testing Method  Also  when using  this method with Commander Downloader software  the names of the muscle  groups are automatically assigned to the tests     Helpful Hint  You should be careful to select the proper test number before starting  a test  and be extremely careful not to inadvertently continue with the n
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
  AirGuard™ Wireless Access Point User's Guide  TLA EQ5013 manual - fra www.interstage.dk  取扱説明書 - 日立の家電品  Geneva Lab FRESH BREW 3205 User's Manual  Playmobil 5455  Sunbeam ST6610 Electric Steamer User Manual  Owner`s Manual  Sony VGNZ899GSB Marketing Specifications    Copyright © All rights reserved. 