Home
        User Manual
         Contents
1.                                                                                                                                                                                                                                                            G 9 Avertismente privind siguran  a la instalare  Romanian     1  Instruc  iuni de instalare         Cititi toate instruc  iunile de instalare   nainte de a conecta    116 Mellanox Technologies       Rev 2 5    2  Accidentare cauzat   de greutate    Apelati la un num  r suficient de persoane pentru a ridica in siguranta acest produs        e e              i      40 Ibs 40   70 Ibs 70   121 Ibs 2121 lbs    18 kgs 18   32 kgs 32   55 kgs  gt 55 kgs       3  Echipament greu    Acest echipament este greu si trebuie s   fie mutat folosind un dispozitiv mecanic de  ridicare pentru a evita producerea de leziuni     4  Risc de soc electric    Risc de soc electric     Odat   ce modulul ventilator este indep  rtat  pinii electrici sunt accesibili in cavitatea  modulului        NU introduceti instrumente sau p  rti din corp in cavitatea modulului ventilator     5  Temperatur   in exces    Acest echipament nu trebuie s   fie actionat intr o zon   unde temperatura ambiant    dep  seste valoarea maxim   recomandat    45  C  113  F     n plus  pentru a asigura un  flux de aer adecvat  l  sati un spatiu liber de cel putin 8 cm  3 inchi  in jurul fantelor de  ventilare        6  Suprapunerea cadrului           a  A N Cadrul nu trebuie s   fie su
2.                                                                                                                               DINA                  Town                                                                                                                      D lt                                                   22                                                                                        TN                                        IT mon                                   gt     Mellanox Technologies       9    9       Rev 1 3    G4                              Chinese   1                                                                                                                         2                                                                                                                                                    lt 40 Ibs 40   70 Ibs 70   121 lbs  gt 121 lbs   lt 18 kgs 18   32 kgs 32   55 kgs  gt 55 kgs    3         4                                                                                                              4                                                    A FRA RA 46              84 AB 22 E Pa RY ERS                                                                                               Eos Eh                                             45  C  113  F   HA   A T URRESRURLE AE                                       8         3 RM  WEEE        6  NETS    AA 9 2 5            E  MRA          BSR         100 
3.                                                                                     CSA                                                                                                                                                                                                                       UL                                                                                                                  CSA   3                    16 AWG                      1 5 M  6                  4 5                                                               125     13 A                                                                                                                                                                                                                    lt HAR gt   3                                                                 1 0 MM                                                                              300                                                                                                                          250      10       Mellanox Technologies 115    Rev 1 3       17                 TOK                                                                                                                                     K  4                                        18                                                   AN                                                   RS232    Ethernet                                         
4.                                                                         12                                                                                                                                                                                                                       H                                                                                                                                                                                                                                                                                                                                                                                                                                                                        15                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                    16                                                                            UL                            
5.                                                                lt        gt      3                DITA                                                  1 0                 V 2    300  DY               PVC                                                                 250    10            98 Mellanox Technologies    Rev 2 5                              17                                           s                                                                                                                                                                                                                                                                                   gt                pa                  18                    MINI                              Ethernet RS232                                   UL     DP 1 non         DP 2                                                                          mo                                                          19                                          333                            DYSON               NIN                               20A          20                                                               PN                  PN                                          Now                                                                                                                                                                        2    21  WEEE                     29             WEEE 2002 96 EC             
6.                                                              8                                                                                                                                                                                                                                                                                                                                                                                                                                                                                             9                                                                                                                                                                                                                                                                                                              InfiniBand                                                                                                                                                                                                                                                                                                                    114 Mellanox Technologies      Rev 2 5      11                                                                                                                                                                                                                                                                                                      
7.                                     CHAT                                                                                                                                                                                                                                                                                                                                     5                                                                                                                                                                                                                                                                         45       113   F                                                                                                                                                                                                       8       3                    6                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                
8.                                    250 V  10       16                       A                                ASR BES REE   17                                                                                                                                                                                                                                                                18  Bien  A            RS232 SEAN ZAMAN RARA UL      DP 1     DP 2     A                          LPS               ERRE                                                                                              20 A                                     19                                                                          BA                                                                                                                                                                                                                                            102 Mellanox Technologies          Rev 2 5    20  WEEE                  WEEE        2002 96 EC   PAREN BSS Tixi  EEE                                          0 8         ARE FE                     21                                                                          TN   RK   tA IT SRA Lo       G 5 Avertissements de s  curit   pour l installation  French     1  Instructions d installation    Veuillez lire la totalit   des instructions d installation avant de relier l   quipement au  secteur        2  Blessures a cause du poids    A    Pr 
9.                                  70  32 AIT FOW s o Nee de asan a    70  3 3 OSFP Cable PowerBudgetClassification                         70  3 4 Management Module Interfaces                                 70  93 4 d 412655 o o pm yel       e ee 71  34 2 CONSOLE     nue od pest dest et      ARE Aa ol sod 71  3 4 3 MGT                                                                71  SAA USB a mea een A BIER 71      RS 72  Chapter 4 Chassis Power                                               73  4 1 Power Supply and Spine Board Indicator Status at Power ON         74  Chapter 5 Switch Management Tools                                  75  5 1 InfiniBand Subnet                                                   76  5 2 Fabric Inspector  Diagnostics                                     76  5 3 Accessing the CPU via the Ethernet Connector                     76  5 4 Upgrading Software  sta si Hama ala ae        AE 76  Chapter 6 Troubleshooting                                           77  6 1 Power Supply Unit                                           77  D2  Leat Board an does en ENS NC see ed          Ped gu 77  6 3 Management Module                                         78  6 4  Spine Board  se    a ARCU RR A 79  6 5 MLNX OS   Software                                         79  Chapter 7 Disassembly and Disposal                                  80  7 1 DisassemblingtiheChassis                                    80  7 1 1 RemovingtheChassis                                    
10.                        6    Y N                                           110                                                               PN  45  C  11390                                                                                                                                           nov                  8           3                        DAV                                                           7    399                                                                                                                     PN                           4                                                bawn     8                            MI                                 IN                                                                                        PN                                                                                                                          4                                          9    MID                                                   4         TON               MIN                                                                     MIN                         pin                                   DITO                                                  nio              10    4                                  PN                                                                         Mellanox Technologies 97      Rev 1 3                                                                                    11             Infi
11.                      41   2 8 Power Connections                                           42   2 8 1 Powering Up the Switch Platform                                 42   2 9 InfiniBand          Cable Installation                               43   2 9 1 Supported Approved Cables                                    44   2 9 2 Cable Power Classes                                         44   2 10 Hot Swap Insertion and Extraction                               44   2 10 1 Power Supply Units                                          45   2 10 2 Leaf Boards                                                47  2 10 3 Spine BoardS   2   2424         WE        50   2 10 4 Fan Modules                                                55   2 10 5 Management Module                                         57   2 10 6 Switch Shut Down Procedures                                  60   Chapter 3  Interfaces     bd awe Lu Ru MERE EIE EE Ed RARE 61  3 1 LED Status Indicators                                         61   3 1 1 Power Supply Unit LEDs                                       61   3 1 2 Leaf Board LED Indicators                                     63   3 1 3 Spine Board LED Indicators                                    64   3 1 4 Spine Side Panel Display LED Indicators                          66   3 1 5 Management Module LED Indicators                             68    Mellanox Technologies 3        InfiniBand FDR Switch Platform Hardware User Manual      3 1 6 Port Connector Interfaces     
12.                  69  Table 14  Management Module S Fan LED Configurations                         69  Table 15  Management Module L Fan LED Configurations                         69  Table 16  Management Module MASTER LED Configurations                      70  Table 17  Switch Specification SX6512  4NIR                                   82  Table 18  Switch System Weight Calculation                                     86  Table 19  PowerConsumptionofChassisParts                                 87  Table 20  OSFPCablePowerConsumption                                    87  Table 21  Calculating Total Switch System Power Consumption                     87  Table 22  InfiniBandosFPConnectorPinout                                   89  Table 23  Replacement Parts Ordering Numbers                                 92  Mellanox Technologies 6                InfiniBand FDR Switch Platform Hardware User Manual      List of Figures    Figure 1  Product Label          her poda rn e Me a b e 13  Figure 2  Product Label Tab Location                                         14  Figure 3  Management Module MAC Address Location                           14  Figure 4 SX6512 Switch Views                                              15  Figure 5  Shelf Installation Kit Parts                                           27  Figure 6  Chassis Installation Parts                                           28  Figure Shock Stickers  starti        nD RES de re nr Si 29  Figure 8  TIU Sticker occas          
13.                 57  Figure 47  Management Module                                              58  Figure 48  Intact vs Defected Signal Connectors                                  58  Figure 49  IntactvsDefectedPowerPinHolders                                 59  Figure 50  Power Supply Unit Status Indications                                 61  Figure 51  PSU Cover      and Off eu ran ER a 62  Figure 52  Leaf Board Led Indicators                                          63  Figure 53  Spine Status LEDS                                                 65  Figure 54  Spine Side Panel Display Status Indications                            67  Figure 55  Management Module Status Indications                               68  Figure 56  Management Module                                                 69  Fig  re  57                           gt  a ence  a ERGO RI 10  Figure 58  Top and Bottom Ports                                              70  Figure 59  Management Module Interfaces                                      71  Figure 60  Reset Buttons semasi      serus de en neue rei nein 72  Figure 61  Spine Side Panel Display Status Indications                            74  Figure 62  Management Module Status Indications for Normal Operation              74  Figure 63  InfiniBand          Connector Symbol                                   90  Figure 64           Connector Male and Female Views                              91    Mellanox Technologies 8        InfiniBand FDR Switch P
14.         1 3 August  2012 Minor changes due to changes in container   1 2 July  2012 Fixed broken link   1 1 July  2012 Added figure to show use of 2nd type of mechanical lift    Added EMI explanation to Appendix  Added explanation to N 2 Power Numbers        1 0 May  2012 Initial release                   About this Manual    This manual provides an overview of the SwitchX   based SX6512 modular InfiniBand  chassis switch  and guidelines for its operation     Intended Audience    This manual is intended for users and system administrators responsible for installing  and setting up the chassis platform     The manual assumes familiarity with the InfiniBand   architecture specification     Related Documentation    The documentation set accompanying the QSFP Chassis InfiniBand Switch platform  includes the following   Table 2  Reference Documents and Websites       Document Name Description       InfiniBand Architecture Specification   The InfiniBand Architecture Specification that is provided by  Vol  1  Release 1 2 1 IBTA                Mellanox Technologies 10    Me RR Fes       InfiniBand FDR Switch Platform Hardware User Manual      Table 2  Reference Documents and Websites       Document Name Description       Switch Product Release Notes For possible hardware issues see the switch support product  page  This reguires a customer support login  Look up the rele   vant SwitchX   based switch system series release note file        Mellanox MLNX OS   User Manual  This document
15.        DP 1    y            DP 2                                                              UL                                 4                                                                                                                                                                                                                                                                                                                                                                                                 20     19                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                     20                                                                                       2002 96 EC  WEEE                                                                                                                                                                                  
16.     80  7 1 2 RemovingtheBottomShelf                                    80  ee 81  Appendix A Specification Data                                        82  A 1 EMI Certification                                           84  A2 Approved Cables                                          84  A3  EMC Certifications  ins nv renk te tethered ta icerik ila 84  Appendix    Thermal Threshold Definitions                             85  Appendix C Calculating the Weight of a Customized Chassis              86  Appendix D Calculating the Power of a Chassis                         87  Appendix E          Interface                                          89  Appendix F Replacement Parts Ordering Numbers                       92  Appendix G Safety Warnings  Multiple Languages                        93  G 1 Nordic Countries Notices                        4           93  G 2 Installation Safety Warnings  English                           93         NAY                                              eee 6  G4                           Chinese    cover Re Rn die 100  G 5 Avertissements de s  curit   pour l installation  French             103  G 6 Installation Sicherheitshinweise German                       106  G 7 Advertencias de seguridad de instalaci  n  Spanish               110  G 8                                                                                                      Russian  113     9 Avertismente privind siguranta la instalare  Romanian            116  G 10 Sigurnosna upozo
17.     Do not use the handles on the fans for lifting or moving the chassis in the rack     Mellanox Technologies 38          InfiniBand FDR Switch Platform Hardware User Manual    Figure 21  Raising the Chassis Using a Mechanical Lift       y d                                                                                                                         O  5    3  Remove the two handles from the sides of the chassis                 4  Push the chassis into the rack until the faceplate is   20cm    8     from the vertical  support     5  Putthe rail slides onto the rails     Figure 22  Put on the Rail Slide       6  Slide the chassis further into the rack     7  Slide the chassis all the way into the rack until the faceplate is touching the vertical  rack support  The caged nuts placed in the last procedure should line up with the  holes in the faceplate     Mellanox Technologies 39        InfiniBand FDR Switch Platform Hardware User Manual      M    Holes in the faceplate for mounting on the    8  Screw the 8 screws through the faceplate and into the caged nuts   9  Slide the rail slides to the vertical rails     Figure 23  SX6512 Chassis on the Shelf             10  Place the 4 holed spacer on the outside of the vertical support and screw in the 4  screws for each rail slide  Use the split lock washers here     11  Remove the two handles from the spine side and save all four handles for future use   12  Ground the switch   13  Install all of the spines  leafs and mana
18.     InfiniBand FDR Switch Platform Hardware User Manual      18  Battery Replacement    A    Warning  Replace only with UL Recognized battery  certified for maximum  abnormal charging current not less than 4mA    There is a risk of explosion should the battery be replaced with a battery of an  incorrect type     Dispose of used batteries according to the instructions     19  UL Listed and CSA Certified Power Supply Cord       For North American power connection  select a power supply cord that is UL Listed  and CSA Certified  3   conductor   16 AWG   terminated with a molded plug rated at  125 V   13 A   with a minimum length of 1 5m  six feet  but no longer than 4 5m     For European connection  select a power supply cord that is internationally    harmonized and marked     lt HAR gt      3   conductor  minimum 1 0 mm  wire     rated at 300 V  with a PVC insulated jacket  The cord must have a molded plug  rated at 250 V  10 A     20  High Leakage Current    A    Warning  High leakage current  Earth connection essential before connecting supply     21  Add GND connection information    da    Before connecting this device to the power line  the protective earth terminal screws of  this device must be connected to the protective earth in the building installation    GND Connection Information     The building installation shall provide a means for a connection to protective earth   and the equipment shall be permanently connected to that by a service person    A SERVICE PERSON 
19.     S     SwitchX   2                Mellanox Technologies 12        InfiniBand FDR Switch Platform Hardware User Manual      1 Overview    This User Manual provides an overview of the SX6512 QSFP Modular InfiniBand  Switch Platform  known in this document as    the chassis or switch     and its operational  environment     Mellanox SX6512 switch systems provide the highest performing fabric solution by  delivering high bandwidth and low latency to Enterprise Data Centers  EDC   High Per   formance Computing  HPC  and Embedded environments  Networks built with the  SX6512 system can carry converged traffic with the combination of assured bandwidth    and granular quality of service  Built with Mellanox   s 5th generation SwitchX   VPI  switch device  SX6512 systems provide up to 56Gb s full bidirectional bandwidth per  port  With up to 216 ports in a 9U high form factor  these systems are among the densest  switching systems available     The switch platform comes pre installed with all necessary firmware for standard opera   tion within an InfiniBand fabric and requires an InfiniBand compliant Subnet Manager  running from one of the hosts or the management module of the switch system  The ini   tial configuration procedure should be followed to initialize the switch before connecting  it to the network after which normal operation can proceed   See the installation guide  for details regarding the initial configuration   Once connected to the network  the Sub   net Managemen
20.     Status  Fan  Bad Port and UID LEDs Leaf connection LEDs    2 9 InfiniBand QSFP Cable Installation    The switch uses industry standard QSFP InfiniBand cables which are available from  Mellanox Technologies  The Mellanox proprietary QSFP cables support full 56 56Gb s   FDR   40 40Gb s  FDR10   40 40Gb s  QDR   20 20Gb s  DDR  and 10 10Gb s   SDR  bidirectional wire speed of the switch ports  All InfiniBand          connections are  made to the leaf boards  Each leaf has 18 InfiniBand QSFP connectors in two rows   which are numbered 1 18  See Section 3 1 6 for port numbering            If maximum cable lengths are exceeded data transfer will be reduced and the bit error  rate will increase   5    must be programmed with management software MLNX OS 3 3 4304 or higher  and     P To raise link at FDR  56Gb s  with 3rd party FDR cables  managed switch systems  yo unmanaged switch systems need SwitchX firmware version 9 2 6000 or higher     Mellanox Technologies 43    m Mi E       InfiniBand FDR Switch Platform Hardware User Manual        FDR and FDR10        only guaranteed to work with approved Mellanox Cables              cables can be inserted or removed with the unit powered on  To insert a cable  press  the connector onto the port receptacle until the connector is firmly seated  The orange  LED indicator above the port will light when the physical connection is established   when both ends of the cable are properly connected to working devices   Allow 15 sec   onds for lin
21.     a    Rail slide        0 M 5 Pan head  ge   screws and    lock washers    4 hole washer           Handles    Screws for  the handles    Caged nuts         gt       lt          2 7 1 3 Container Mishandling    The container has shock and tilt stickers applied  The shock stickers turn red if the con   tainer has been mishandled or roughly handled  Upon receipt of the container look for  and inspect the shock and tilt stickers to confirm that they have not tripped  If a shock  sticker or more are red  or if the tiltwatch sticker indicates more than 40    notify the ship   per and Mellanox  This on its own does not indicate damage to the contents  But  be sure  to carefully inspect the contents if any of the shock and tilt stickers have tripped     Mellanox Technologies 28        InfiniBand FDR Switch Platform Hardware User Manual      Figure 7  Shock Stickers        WARNIN           Stickers unaf         fected by shipping    WARNIN       WARNING       Stickers showing      excessive shock       Figure 8  Tilt Sticker       2 7 1 4 Opening the Container  1  Before starting the procedure  put the ESD strap on and connect it to a valid ground     2  Open the crate by unscrewing the sides and top of the crate     Mellanox Technologies 29        InfiniBand FDR Switch Platform Hardware User Manual         Figure 9  Opening the Container       Container screws    Y It is highly recommended to have a screw gun or electric screwdriver for this step       Unscrew the sides of the cra
22.     on page 87       1 7 January  2014 Rearranged document  Consolidated installation sections under Chapter 2      Installation     on page 19  updated Chapter 1     Overview     on page 13   and re ordered sections     Added      Figure 56     Management Module LEDs     on page 69   Updated    e Section 1 4     Power Supply Redundancy     on page 16   e Section 2 7 1 5     Installing the Shelf     on page 30   e Section 2 7 2     Installing the Cable Holder     on page 34     FDR note in Section 2 9     InfiniBand          Cable Installation     on page 43  e Section 2 10     Hot Swap Insertion and Extraction     on page 44     Section 7 1     Disassembling the Chassis   on page 80     Table 17     Switch Specification SX6512  4N R     on page 82     Appendix D     Calculating the Power of a Chassis     on page 87                   Mellanox Technologies 9    m M              InfiniBand FDR Switch Platform Hardware User Manual      Table 1   Revision History of this User s Manual       Revision Date Details       1 6 June 2013 New graphics   Changed PSU input power numbers to match the chassis power numbers   both are measured at AC voltage not the DC side    Added filler panel   rearranged parts lists    Add Graphic showing the chassis with the filler panels   New Safety warnings       1 5 October 2012   Added Warning for handles       1 4 September 2012   Added figure 23   Added information regarding inserting the bottom spine first  Insert spines  from bottom to top      
23.    InfiniBand FDR Switch Platform Hardware User Manual      3 1 2 Leaf Board LED Indicators    Figure 52  Leaf Board Led Indicators       3 1 2 1 Status LED    Each leaf board has a Status LED on the far left ofthe leaf  Table 4 shows the leaf status  according to the LED condition     The Leaf Status indicator LED A has the following LED assignment     Table 4   Leaf Status LED                      LED Condition LED Description  Off No power to the Leaf  Solid Green Leaf is up and running  Flashing Green Leaf is powering up  Solid Orange Non fatal error     this leaf needs troubleshooting  but does not require  chassis shutdown  Solid Red Fatal error                3 1 2 2 Bad Port LED        The        Port indicator is located on the left side of the leaf  The following Bad Port con   ditions are possible   Table 5   Bad Port LED Configurations             LED Configuration Description  Off OK   all ports are up and running   Flashing Orange Error     one or possibly more ports has just received a  symbol error                This LED shows symbol errors  Possible causes for this are     bad cable    bad connection      bad connector    Mellanox Technologies 63        InfiniBand FDR Switch Platform Hardware User Manual      M    3 1 2 3    3 1 2 4    This LED lights up when one or more ports is receiving a symbol error  The LED imme   diately goes off until the next symbol error is received     UID LED Switch Identifier    The UID LED is a debug feature that will become av
24.   According to the WEEE Directive 2002 96 EC  all waste electrical and electronic  equipment  EEE  should be collected separately and not disposed of with regular  household waste    Dispose of this product and all of its parts in a responsible and environmentally    friendly way        21  Country of Norway Power Restrictions  Norway only     A This unit is intended for connection to a TN power system and an IT power system of                                           G3   nmay                                 1    A                                                                   MANN                               mr                          2                                            PN                                                                                               A                                                                                  32                                                               nm      3                                   1900                19                                         4                         4                                                                                                           A       6 Mellanox Technologies      Rev 2 5      5                      nio                                    gt                                                                                                             PR                  0525                        222                                           
25.   En  general  en un bastidor  los eguipos se deben instalar comenzando desde abajo hacia    arriba     12  Instalaci  n del equipo        La instalaci  n  el reemplazo y el mantenimiento de este equipo estar  n a cargo   nica   A   mente de personal capacitado y competente            La eliminaci  n definitiva de este equipo se debe efectuar conforme a todas las leyes y      reglamentaciones nacionales     Mellanox Technologies 111      Rev 1 3      14  C  digos el  ctricos locales    nacionales        Este equipo se debe instalar conforme a los c  digos el  ctricos locales y nacio    4   males         ___       15  C  digos de instalaci  n    Este dispositivo se debe instalar conforme a la version mas reciente de los c  digos  el  ctricos nacionales del pais en cuesti  n  En Am  rica del Norte  el equipo se debe  instalar de acuerdo con las disposiciones vigentes del C  digo El  ctrico Nacional de los  EE UU  y del C  digo El  ctrico de Canada        16  Cable de alimentaci  n homologado por UL y con certificaci  n CSA    En conexiones de Am  rica del Norte  seleccionar un cable de alimentaci  n  homologado por UL y con certificacion CSA de tres conductores   16 AWG   termi   nado en un enchufe moldeado con capuch  n de 125 voltios nominal   13 A   con una  longitud minima de 1 5 metros  pero no m  s de 4 5 metros        En conexiones europeas  seleccionar un cable de alimentaci  n armonizado  internacionalmente y marcado   lt HAR gt    de tres conductores  hilo de 1 0 mm2 
26.   by 43  Figure 28  Power Cord Numbering       2      22 2 2   a cc2rcrrrrracacrrraacrris 45  Figure 29  PSU Locations sia LR ark Laurie 46  Figure 30  Power Supply                                       46  Figure 31  Leaf Board Numbering                                             47  Figure 32  Ejector Handle Ausser      e eq Saree eae A 48  Figure 33  Lear Release ur mpini i ne a 48  Figure 34  Intact vs Defected Signal Connectors                                  49  Figure 35  Intact vs Defected Power Pin Holders                                  49  Figure 36  Management Module Numbering                                     51  Figure 37  Spine Board Extraction                                            51    Mellanox Technologies 7        InfiniBand FDR Switch Platform Hardware User Manual      Figure 38  Intact vs Defected Mechanics                                        53  Figure 39  Intact vs Defected Side Signal Connectors                              53  Figure 40  Intact vs Defected Middle Signal Connectors                            54  Figure 41  Intact vs Defected Power Pin Holders                                  54  Figure 42  Spine Board Insertion Caution                                       54  Figure 43  Leaf Fan Locations on the Chassis                                    55  Figure 44  Leaf Fan Module Extraction                                         56  Figure 45  Spine Fah Module  ii         an 56  Figure46 FanStatusLEDontheSpineModule                 
27.  825 1 1993   A1 1997   A2 2001 and EN 60825 1 1994 A1 1996     A2 2001    25  Proper Enclosure       A suitable electrical  mechanical and fire enclosure shall be provided by the end prod   uct manufacturer and or the end user     26  Do Not Use the Switch as a Shelf or Work Space    Y    Caution  Slide rail mounted equipment is not to be used as a shelfor a work space  The  rails are not intended for sliding the unit away from the rack  It is for permanent instal   lation at final resting place only  not used for service and maintenance    27  WEEE Directive    X    According to the WEEE Directive 2002 96 EC  all waste electrical and electronic  equipment  EEE  should be collected separately and not disposed of with regular  household waste    Dispose of this product and all of its parts in a responsible and environmentally  friendly way     28  Country of Norway Power Restrictions       This unit is intended for connection to a TN power system and an IT power system of  Norway only     2 2 Environmental and Safety Recommendations    The following are Mellanox recommendations     V    ellanox Technologies       Recommended ambient temperature in the System room is 20     5   C   Recommended humidity range is 40    15  without condensing        23          InfiniBand FDR Switch Platform Hardware User Manual    It is highly recommended that the installation sites be as isolated as possible from all  sources of radio transmissions and electrical interference        It is highl
28.  AR 29  Figure 9  Opening the Container                                             30  Figure 10  Placement of Chassis    Rack                                       31  Figure 11  Inserting the Caged Nuts for the Shelf                                 31  Figure 12  Connect Rail Slide to Rack Vertical support                             32  Figure 13  Inserting the Caged Nuts for the Faceplate                             32  Figure 14  Chassis on Shelf with Filler Panel                                     33  Figure 15  Cable Holders 22 2 R34 er ae he 34  Figure 16  Cable Holder Placement                                            35  Figure 17  Chassis Rails and Rail Slides                                        36  Figure 18  Installing the Handles                            ee 37  Figure 19  Screw the Handles Onto the Chassis                                  37  Figure 20  The Rails are Already Connected Onto the Chassis                      38  Figure 21  Raising the Chassis Using a Mechanical Lift                            39  Figure 22  Put on the Rail Slide rei RE u ne rk a na 39  Figure 23  SX6512 Chassis on the Shelf                            4 5           40  Figure 24  Face Plate Mounting Bolt Locations                                   40  Figure 25  Ground Connection                                               41  Figure 26  Multiple Power Inlets     Electric Caution Notification                       42  Figure 27 pine Module    t2 these        A   le e at  
29.  Chassis fam     ily and switch chip generation     Mellanox Technologies 44    e m       InfiniBand FDR Switch Platform Hardware User Manual    When hot swapping any of the units  it is necessary to wait 1 minute after removing  the defective part before inserting the new part  This is necessary so that the manage   ment module will start a new cycle checking through the leafs and spines for the FW   versions        This switch platform supports hot swap capabilities for the parts listed below      Power supply units     Leafboards       Spine boards     Leaf fan module     Spine fan module      Management modules    2 10 1 Power Supply Units    The 1000W power supplies deliver 1000W at 48V  The input to each of these power sup   plies requires 1176 5W in order to output 1000W     The 1670W power supplies deliver 1670W at 48V  The input to each of these power sup   plies requires 1882 4W in order to output 1670W     For N 1 configuration PSUs  Power Supply Unit  can be extracted without bringing  down the system     For       configuration up to half of the PSUs can go down and the system will continue  to run     The power required to run the switch system is equally divided between all of the work   ing PSUs     2 10 1 1 Extracting and Inserting the Power Supply Unit  With all of the 1000W power supplies installed  the system is in N 1 redundant configu   ration   With all of the N N 1670W power supplies installed  the system is in N  N redundant  configuration  half of th
30.  InfiniBand FDR Switch Platform Hardware User Manual      4  Installation in Restricted Access Location    This unit is intended for installation in a Restricted Access Location        3  Risk of Electric Shock     Risk of Electric Shock     LA With the fan module removed power pins are accessible within the module cavity   DO NOT insert tools or body parts into the fan module cavity     6  Over temperature    This equipment should not be operated in an area with an ambient temperature exceed   ing the maximum recommended  45  C  113  F   Moreover  to guarantee proper air  flow  allow at least 8cm  3 inches  of clearance around the ventilation openings        7  Stacking the Chassis    The chassis should not be stacked on any other equipment  If the chassis falls  it can  cause bodily injury and equipment damage     8  Redundant Power Supply Connection   Electrical Hazard    power supply  do not operate the product with the blank cover removed or not securely    This product includes a redundant power or a blank in its place  In case of a blank  A fastened     9  Double Pole Neutral Fusing    This system has double pole neutral fusing  Remove all power cords before opening  the cover of this product or touching any internal parts     10  Multiple Power Inlets      Risk of electric shock and energy hazard     The PSUs are all independent   Disconnect all power supplies to ensure a powered down state inside of the switch  platform     Mellanox Technologies 20    e HEN      Infi
31.  PSU status indicators will turn off     Remove the PSU    To insert a PSU    Make sure the mating connector of the new unit is free of any dirt and or obstacles   Insert the PSU by sliding it into the opening until a slight resistance is felt     Continue pressing the PSU until it seats completely  The latch will snap into place  confirming the proper installation     Insert the power cord into the supply connector on the other side of the chassis     Mellanox Technologies 46        InfiniBand FDR Switch Platform Hardware User Manual      M    5  Replace the cover over the PSUs     The green indicators should light  If not  extract the PSU and re insert it again        2 10 2 Leaf Boards      Do NOT mix replacement parts based on different generations of chip        Do not install InfiniScale IV based replacement parts within a SwitchX   based chas   sis and vice versa  All Replacement modules must be consistent with the Chassis fam       ily and switch chip generation     When hot swapping any of the units  it is necessary to wait 1 minute after removing  the defective part before inserting the new part  This is necessary so that the manage   ment module will start anew cycle checking through the leafs and spines for the FW  versions        The leaf boards are numbered from top to bottom  with corresponding numbers dis   played to the outside of the leafs vertically along the side panel     Figure 31  Leaf Board Numbering       L1 L2  L3 L4  L11        112    2 10 2 1 Extra
32.  Sigurnosna upozorenja za instaliranje  Croatian     1  Upute za instaliranje    Pa  ljivo pro  itajte upute za instaliranje prije spajanja opreme na izvor elektri  ne  energije        2  Tjelesne ozljede uslijed te  ine    Kako biste sigurno podignuli ovaj proizvod  koristite dovoljan broj ljudi         lt 40 Ibs 40   70 Ibs 70   121 lbs  gt 121 Ibs   lt 18 kes 18   32 kc3 32   55 kgs  gt 55 kge    3  Te  ka oprema      Ova oprema je vrlo te  ka i treba se premje  tati pomo  u mehani  kog dizala kako bi se  izbjegle ozljede     4  Rizik od strujnog udara     Rizik od strujnog udara   S uklonjenim modulom ventilatora  perima napajanja se mo  e pristupiti u otvoru mod   ula        NEMOJTE umetati alat ili dijelove tijela u otvor modula ventilatora     5  Pregrijavanje    y  Ovom se opremom ne bi trebalo rukovati u podru  jima s temperaturom okoline koja  y N prema  uje najvi  e preporu  ene vrijednosti  45  C  113  F   Osim toga  kako bi se osigu   4    rao odgovaraju  i protok zraka  omogu  ite najmanje 8 cm  3 in  a  razmaka oko otvora                  ventilatora     6  Slaganje ku  i  ta    i Ku  i  te se ne bi trebalo slagati na drugu opremu  Ako ku  i  te padne  mo  e izazvati tje   lesne ozljede i o  te  enje opreme     120 Mellanox Technologies      Rev 2 5      7  Redundantno napajanje   Opasnost od elektri  ne energije    U slu  aju praznog prostora za napajanje  nemojte rukovati proizvodom ako je pok     a Ovaj proizvod uklju  uje redundantno napajanje ili prazan pr
33.  User Manual      Table 22   InfiniBand OSFP Connector Pinout          Connector O  Pin    Signal Description  Pin Name  Number  30 Vecl   3 3 V Power Supply       31 LPMode   Low Power Mode                         32 GND Ground   33 Tx3p Transmitter Non Inverted Data Input  34 Tx3n  Transmitter Inverted Data Input   35 GND Ground   36 Txlp  Transmitter Non Inverted Data Input  37 Txln  Transmitter Inverted Data Input   38 GND Ground                   Figure 63  InfiniBand QSFP Connector Symbol                J3 and J6       20 GND GND    12  21   Rx2n Rx1n 18  22 Rx2p Rx1p   17  23        GND   16  24 15   Rx4n Rx3n  14   23 Rx4p Rx3p  13   28 GND GND  i ModPrsL SDA 12  11   28 IntL SCL  10   29 VECIX Vcc Rx  su Veci ResetL 9  31 LPMode ModSelL 3  32 GND GND 7  33   Tap Tx4p              34 Tx3n Tx4n 5      35        GND        36 Tx1p Tx2p 3           Tx2n     2      38   GND GND 1   Mellanox Technologies 90     gt  om      InfiniBand FDR Switch Platform Hardware User Manual      Figure 64  QSFP Connector Male and Female Views                         Top  View into Rear of 18 35  Connector         E nn    8  lt  y     9 889 229 7 5 8 8 8 5          9 x 9    G38 o 5    O ff    lt  4    0 8 5 6 se             O a    oo 0  lt  J   0 1                25 28 F E  O 3 5 0   o  gt  20 on    5 5 Vs 35 U            2  HP 18 35         View into Front of Cage    8 50             Mellanox Technologies 91        InfiniBand FDR Switch Platform Hardware User Manual    Appendix F  Replacem
34.  bringing down the system  When using the 1000W PSUs  the mini   mum complement of PSUs at start up is 4 and the chassis will continue to run at full  capacity with only 3 PSUs     1 4 2 1670W Power Supply Units    The 1670W power supply units  PSUs  deliver 1670W at 48V  The AC source to each  PSU must be able to provide 1882 4W in order to output 1670W in DC     When using the 1670W PSUs  the minimum complement of PSUs which allows the  chassis to run at full capacity is 2     The 1670W PSUs can implement the following two redundancy options   e No redundancy  combined mode   e N 1 configuration  ps redundant mode     When supplied from a single 220V power grid  the chassis supports up to 2 redundant units   Thereby  the minimum required number of PSUs equals 2  When supplied by a single 110V  power grid  the number of redundant power supplies is only 1             configuration  grid redundant mode     A         y N NN redundancy ONLY works with a supply voltage of 220V     The chassis PSUs are fed from two power grids for high availability  The second power grid  can be supplied by any of the following    e 8 backup power supply grid        generator   e a battery backup system     any combination of the above   Connecting 2 power supplies to one power supply grid and the remaining 2 power supplies to  a secondary power supply grid will create N N redundancy  This is High Availability  Under  these conditions should a power grid fail  an electric company power failure or 
35.  contains information regarding configuring and  for VPI managing Mellanox Technologies SwitchX   switch platforms  listing all ofthe commands available through MLNX OS with  explanations and examples                 Conventions    Throughout this manual  the name SX6512 and the terms chassis and switch are used to  describe the 216 port QSFP InfiniBand chassis  unless explicitly indicated otherwise     The following icons are used throughout this document to indicate information that is  important to the user     Y This symbol makes recommendations to the user         This symbol indicates information that is helpful to the user     This symbol indicates a situation that can potentially cause damage to hardware or  software        Warning  This symbol indicates a situation that can potentially cause personal injury  and   or damage to hardware or software        Mellanox Part Numbering Legend             Place Field Decoder  M Mellanox Technologies  SX System Type SwitchX amp  Switch       PR Data Transfer Protocol  1  2  3  4    Ethernet  5  6  7  8    InfiniBand                G Module Generation 5  6  7  8          Mellanox Technologies 11    NN     gt       InfiniBand FDR Switch Platform Hardware User Manual               Place Field Decoder  FF Number of leafs 36  18  12  06  C Data Rate      40Gb s Ethernet    F   FDR  T  FDR10       QDR  D   DDR               Separator   P   Power Supplies      NIN redundant  1 1PSU  2 2PSUs        R Chip Generation R     SwitchX     
36.  mantenimiento    21  Directiva WEEE    Conforme a la Directiva 2002 96 CE sobre RAEE  todos los residuos de equipos el  c   tricos y electr  nicos  EEE  se deben recolectar por separado y no se deben eliminar  junto con residuos dom  sticos     Al deshacerse de este producto y de todas sus partes  h  galo de una manera respons   able y respetuosa con el medio ambiente     6 8                                                                                                      Rus   sian     1                                                                                                                                                                                                                                                      2                                                                                                                                                                                                                       AR Tre      40 Ibs 40   70 Ibs 70   121 Ibs 2121 lbs    18 kgs 18   32 kgs 32   55 kgs  gt 55 kgs       3                                                                                                                                                                                                                            BO                                   Mellanox Technologies 113         Rev 1 3      4                                                                   TOKOM                                                           
37.  no power enable  lt module gt    For example to shut  down spine 06 run the command below     switch  master   config    no power enable S06    2  Push outward on the ejector handles to unlock the ejectors from the chassis     3  Open the ejectors until they are at a 45 degree angle from the module     IN  N       y N Do not use the fan FRU handle to extract the spine board          4  Pull out the module half way through the guiding rails using both ejectors   5  Lock the ejector handles        6  Hold the body of the board on both sides and remove it from the chassis     Mellanox Technologies 52            InfiniBand FDR Switch Platform Hardware User Manual       2 10 3 2 Inserting a Spine Board    When hot swapping any of the units  it is necessary to wait 1 minute after removing  y N the defective part before inserting the new part  This is necessary so that the manage     ment module will start a new cycle checking through the leafs and spines for the FW  versions    To insert a spine board    1  Check for foreign objects in or mechanical damage to the chassis spine slots     2  Check spine mechanics for any noticeable damage or deviations from the pass crite   rion shown in Figure 38     Figure 38  Intact vs Defected Mechanics       3  Check back signal connectors    integrity  Look for any broken signal dividers or any  deviations from the pass criteria shown in Figure 39 and Figure 40     Figure 39  Intact vs Defected Side Signal Connectors       Pass             2  
38.  of the chassis     3  Push the fan module until the latch engages     4  Make sure that the green leaf LED on the module comes on  indicating that fan is  running      2 10 4 2 Spine Fan Modules    Each spine module has a fan module with two individual fans built in  When a fan mod   ule is not functioning the Fan Status LED on the spine will light up     Figure 45  Spine Fan Module          Fan module    When a fan module is removed the indicator light will reset     Mellanox Technologies 56        InfiniBand FDR Switch Platform Hardware User Manual      M    Figure 46  Fan Status LED on the Spine Module                       Fan status LED    Extracting the Spine Fan Module  1  Push the two blue latch buttons together while pulling the fan module out     Inserting the Spine Fan Module    When hot swapping any of the units  it is necessary to wait 1 minute after removing  the defective part before inserting the new part  This is necessary so that the manage   ment module will start a new cycle checking through the leafs and spines for the FW  versions        1  Make sure the fan module is oriented correctly top side up  Confirm that the location  ofthe connector in the chassis will line up with the connector in the fan module   2  Slowly slide in the new spine fan module     3  Push the fan module as far as it will go  make sure the locking latches engage      gt     Ifthe Fan LED continues to show red remove the fan module and check the pins on the  connector inside of the
39.  onayl   DP 1 veya DP 2 tipi olmas   gerekir   Not  LPS olmayan devreye aitse   A    r   Ak  m Korumas    Kolayca eri  ilebilecek 20 V Kay  tl   devre par  as   a    r    ak  m koruma cihaz  n  n bina elektrik   ebekesinde kurulu olmas   gerekir        19  Anahtar   Raf veya   al    ma Alan   olarak kullanmay  nl    Dikkat  S  rg  l   rayl   ekipman raf veya   al    ma alan   olarak kullan  lamaz  Raylar    niteyi iskeleden uza  a kayd  rmak i  in yap  lmam    t  r  Sadece  ekipman  n son olarak  duraca     yerdeki kal  c   montaj i  indir  servis veya bak  m i  in kullan  lamaz     Mellanox Technologies 129          Rev 1 3    20  WEEE Y  nergesi    WEEE Y  nergesi 2002 96 EC uyar  nca  t  m elektrikli ve elektronik ekipman at  klar       EEE  ayr   olarak toplanmal   ve evsel at  klarla birlikte     pe at  lmamal  d  r   X   Bu   r  n ve t  m par  alar     evreye dost ve sorumlu bir   ekilde imha edilmelidir   Le      21  Norve   G     K  s  tlamalar      Bu   nite  bir TN g     sistemine ve sadece Norve   in TT g     sistemine ba  lanmak  i  indir   Sp    G 13 Japan VCCI Class A Statement    CORBIS  772        Cd  COREE XRRR CHATS                     5 02  6 9  3                DIE 758               5   416     08 0 3    VCCI A            130 Mellanox Technologies      
40.  or more of the spine fans is bad  User should check   individual spine fan LEDs for fault indications   LEAF FANS   Off    No power to fan Green  STATUS Green     Nominal operational   Red     One or more of the leaf fans is bad  User should check   individual leaf fan LEDs for fault indications   MNGI Off   Green  MASTER   no power  STATUS   this management module is not installed     this management module is not the master   Green     Management module is operating as a master  MNG2 Off  Off  MASTER   no power  STATUS   this management module is not installed     this management module is not the master  Green     Management module is operating as a master                   Mellanox Technologies 67               InfiniBand FDR Switch Platform Hardware User Manual    3 1 5 Management Module LED Indicators    Figure 55  Management Module Status Indications          The management module LEDs display the switch system operating conditions     Table 12   Management LED Display for Normal Operation                                     sti ga Normal  LED Condition Description State  STATUS Off     No Power Green  This LED Green     System is up and running  shows the sta    Yellow     System warning  Attention needed  such as overheating   tus of the chas   Red     System not operational  Diagnostics fail  CPU hang  HW fail   sis  Overheat critical  Blinking green     System booting   Restore factory defaults in progress  PSU STATUS  Off  No power Green  Green     Normal operati
41.  or not working  hot swapping the  spine board connected to the master management board will cause the chassis to crash     or spine  2  as the management modules are connected to the chassis components        Neither the CLI nor the GUI management tools will allow you to shut down spine   1   gt  through these spines     Extracting Spine Board  1 or  2    Spine board  1 is connected to management board  1 and spine board  2 is connected to  management board  2     MNGI management module  1   top    MNG2 management module  2   bottom        Removing spine  1 causes management module  1 to reset   Removing spine  2 causes management module  2 to reset     Warning  Ifthe spine you want to hot swap is connected to the master management  module the management module will reboot when you take out the spine   If you have only one management module the chassis will crash        Figure 37  Spine Board Extraction  Pull the ejector handles out to remove the spine     ade ep 15 17 1 21 23 25 27 29 31 33 35    12 14 16 18 2g 22 24 26 28 30 32 34 35       Mellanox Technologies 51         InfiniBand FDR Switch Platform Hardware User Manual      If you need to hot swap spine  1 or spine  2     1  Check to see ifthe spine you need to remove is connected to the master management  module  See Figure 36        A If you have only one management module  the chassis will crash   a    2  Follow the steps in Section below     Extracting Spine Boards Except  1 or  2    1  Run the shut down command   
42.  si cu o manta izolant    din PVC  Cordonul de alimentare trebuie sa fie prevazut cu o fi     turnat   cu putere  nominal   egal   cu 250 V  10 A     17  Curent de scurgere de inalt   frecvent      Avertisment  Curent de scurgere de inalt   frecvent    Imp  m  ntarea este esential    inainte de a conecta sursa de alimentare        18  Interconectarea unit  tilor    Cablurile pentru conectarea la unitatea RS232 si la interfetele Ethernet trebuie s   fie de  tipul DP 1 sau DP 2 certificate UL   Not    c  nd se reg  sesc intr un circuit non LPS   Protectie la supracurent  Un dispozitiv de protectie la supracurent  inregistrat in cir   cuitul de ramificare  usor accesibil si cu o putere nominal   egal   cu 20 A trebuie s   fie  integrat in cablajul cladirii        19  Nu utilizati comutatorul ca raft sau spatiu de lucru    Atentie  Echipamentul montat pe o linie de alunecare sin   nu va fi utilizat ca raft sau  spatiu de lucru  Scopul sinelor nu este de a glisa unitatea de pe rack  Acestea sunt des   tinate instal  rii permanente numai la punctul final de oprire si nu vor fi folosite pentru  depanare si intretinere    20  Directiva DEEE      n conformitate cu Directiva DEEE 2002 96 CE  toate de  eurile de echipamente elec   trice   i electronice  EEE  trebuie colectate separat si nu trebuie eliminate   mpreun   cu  deseurile menajere obisnuite    Eliminati acest produs si toate componentele sale in mod responsabil si ecologic     Mellanox Technologies 119          Rev 1 3    G 10
43.  spine to make sure that none of them are bent     2 10 5 Management Module    When hot swapping any of the units  it is necessary to wait 1 minute after removing  the defective part before inserting the new part  This is necessary so that the manage   ment module will start anew cycle checking through the leafs and spines for the FW  versions      gt     Extracting a Management Module    Management modules are located on the leaf side  above the leafs  There are two places  to install the management modules     Only one management module is required to run the switch system     ellanox Technologies 57       InfiniBand FDR Switch Platform Hardware User Manual       Each management module has a pair of ejectors that lock the board in place and serve as  a lever for seating or extracting  see Figure 47      1  Run the shut down command    no power enable  lt module gt      For example to shut  down management module 2 run the command below     switch  master   config    no power enable MGMT2    Disconnect all cables connected to the management module    Push outward on the ejector handles to unlock the ejectors from the chassis   Open the ejectors until they are 45 degrees from the module    Pull out the module half way through the guiding rails using the ejector handle   Lock the ejector handle     aD    Hold the body of the board on both sides and remove it from the chassis     Y N The board is short  therefore do not let go of it while sliding it out     Figure 47  Managemen
44.  the PSU grounds  It is absolutely necessary to connect the grounding post   Make sure the connections are solid and permanent  If you choose to not use the ground  screw  make sure that the rack is properly grounded and that there is a valid ground con   nection between the chassis of the switch and the rack        Warning  System grounding must comply with local electrical code     Figure 25  Ground Connection          ESD connector Ground Post    Mellanox Technologies 41    UU      InfiniBand FDR Switch Platform Hardware User Manual      M    2 8    2 8 1    Power Connections    The switch includes integrated hot swap power supplies which support up to 4 load shar   ing 1000W or 1670W supply units  The slots for the power supply units  PSUs  are on  the spine side  The left side has odd numbered PSUs and the right side has even num   bered PSUs  Each PSU has a dedicated AC inlet  This design enables the optional use of  separate main and backup AC feeds  The input voltage is Autorange  100 240 VAC   50Hz or 60Hz  The output voltage for the PSUs is 48V  The power cords should be stan   dard 3 wire AC power cords including a safety ground     Powering Up the Switch Platform       A Make sure that the power cords are compatible with your outlets  Power cords for dif          ferent countries can be ordered from Mellanox             The chassis in N 1 mode must be started with a full complement of PSUs  thereafter it  can run on one less than the total number of PSUs  This fin
45.  the leaf board   1  Check for foreign objects in or mechanical damage to the chassis leaf slots     2  Check leaf mechanics for any noticeable damage     Mellanox Technologies 48         InfiniBand FDR Switch Platform Hardware User Manual      3  Check back signal connectors    integrity  Look for any broken signal dividers or any  deviations from the pass criterion shown in Figure 34        Figure 34  Intact vs Defected Signal Connectors    m    Fail       4  Check power connector   s integrity  Look for any damage on the power connector  casing or blades damage  or any deviations from the pass criterion show in Figure 35     Figure 35  Intact vs Defected Power Pin Holders       5  Start with the ejector handle fully open  that is  at 45 degrees to the front panel of the  leaf     6  Holding the leaf by its sides  carefully set the leaf board into the chassis     Mellanox Technologies 49        InfiniBand FDR Switch Platform Hardware User Manual      7  Applying equal pressure on both sides of the leaf board  slowly slide the board into  the chassis until the ejector handle reaches the vertical bar     AN  N        Do not apply excessive force to slide in the leaf board  If you feel resistance  remove      the leaf board and double check both the chassis and leaf for any damage          8  Catch the hook onto the vertical bar ofthe chassis and push the ejector handle shut   9  Lock the ejector handle onto the board     2 10 3 Spine Boards    Do NOT mix replacement parts bas
46.  trique nationaux  En Am  rique du Nord  l   quipement doit   tre install   en respectant  les exigences de l US National Electrical Code et du Code canadien de l   lectricit          16  Cordon d alimentation UL Listed et certifi   CSA    Pour le branchement   lectrique en Am  rique du Nord  utiliser un cordon d alimenta   tion UL Listed et CSA Certified     3 conducteurs  calibre 16 AWG   avec une prise  moul  e 125 V  13 A   faisant au moins 1 5 m de long  six pieds  et au plus 4 5 m   Pour le branchement   lectrique en Europe  utiliser un cordon d alimentation au format  international harmonis    marqu    lt HAR gt       3 conducteurs d au moins 1 mm2 de sec   tion  300 V  avec une gaine isolante en PVC  Le cordon doit avoir une prise moul  e  250 V 10 A        17  Courant de fuite   lev      Avertissement   courant de fuite   lev    une connexion    la terre est indispensable  avant de brancher l alimentation     Mellanox Technologies 105    Rev 1 3       18  Interconnexion des unites    A Les c  bles de connexion aux interfaces RS232 et Ethernet de l appareil doivent   tre        certifi   UL de type DP 1 ou DP 2   Note   en cas d installation sur un circuit dont la        puissance n est pas limit  e     Protection contre les surintensit  s   le c  blage de l immeuble doit int  grer un dispositif    certifi   de protection contre les surintensites  calibre a 20 A et aisement accessible   19  Ne pas utiliser comme   tag  re ou plan de travail   Attention   un   quipemen
47.  ventilaci  n        6  Apilamiento del chasis    A IN Los chasis no se deben apilar sobre otros eguipos  La caida del chasis podria causar      lesiones corporales  asi como da  os al equipo     110 Mellanox Technologies      Rev 2 5      7  Conexi  n redundante de fuente de alimentaci  n  peligro de descarga    Si se dispone de una fuente de alimentaci  n vacia  no utilizar el producto si su tapa    Este producto incluye una fuente de alimentaci  n redundante o  en su lugar  una vacia   A esta quitada o no esta bien cerrada     8  Tomas de alimentaci  n multiples    Riesgo de descarga el  ctrica y peligro de corriente   Todas las fuentes de alimentaci  n son independientes     Desconecte todas las fuentes de alimentaci  n  para asegurar que no haya corriente  alguna dentro de la plataforma de conmutaci  n      gt     9  Al haber rayos  peligro de descarga    No utilizar el equipo ni conectar o desconectar cables durante periodos de actividad de  LA rayos     10  Cable de conexi  n y desconexi  n InfiniBand de cobre    Dado que los cables de cobre InfiniBand son pesados y no son flexibles  su conexi  n a  los conectores y su desconexi  n se deben efectuar con mucho cuidado  Para ver adver   tencias o instrucciones especiales  consultar al fabricante del cable        11  Montaje y mantenimiento del bastidor    Al instalar o realizar el mantenimiento de este aparato en un bastidor  es preciso    adoptar precauciones especiales para garantizar que el sistema se mantenga estable
48.  voyez assez de personnel pour soulever ce produit en toute s  curit           lt 40 Ibs 40   70 Ibs 70   121 Ibs  gt 121 Ibs   lt 18 kgs 18   32 kgs 32   55 kgs  gt 55 kgs    3    quipement lourd      Cet   quipement est lourd et doit   tre d  plac   avec un systeme de levage m  canique  pour   viter les blessures     Mellanox Technologies 103         Rev 1 3      4  Danger d   lectrocution    AN Danger d electrocution    4   Lorsque le module de ventilation est retir    les broches d alimentation sont expos  es  A   dans l emplacement du module        NE PAS ins  rer d outils ou la main dans l emplacement du module     5  Surchauffe    Cet   quipement ne doit pas  amp tre en service dans un local dont la temp  rature d  passe le      maximum recommand   de 45  C  113  F   En outre et pour garantir une circulation  y d air correcte  laisser un espace d au moins 8 cm  3   autour des orifices de ventilation        6  Ch  ssis empil   sur d autres   quipements      Le ch  ssis ne doit pas   tre empil   sur d autres   quipements  S il tombe  il peut endom   mager l   quipement ou entra  ner des blessures     7  Connexion de l alimentation redondante   danger d   lectrocution    Ce produit est   quip   d une alimentation redondante ou d un cache si elle est absente   Dans ce dernier cas  ne pas faire fonctionner le produit si le cache est retir   ou mal  fix        gt     8  Plusieurs prises d alimentation    Risque et danger d   lectrocution   Les alimentations sont toutes ind  
49. 1 Overview wsdl sss ster ei COs lele ERE 13  1 1 Product Information                                       2  13   1 1 1 Serial Number and Product Version Information                     13   1 1 2 Management Module MAC                                     14   1 1 3 Product Physical Specifications and Power                        14   1 27 Features  List  near  a Roe er Dot a au Da       m ears 16   1 3 InfiniBand        and FDR10 Overview                            16   1 4 Power Supply Redundancy                                    16   1 4 1 1000W Power Supply Units                                     17   1 4 2 1670W Power Supply Units                                     17   Chapter 2 Installation ss seke ea           sles 19  2 1 Installation Safety Warnings                                    19   2 2 Environmental and Safety Recommendations                      23   2 3 Chassis Package                                                     24   24    Leaf Package                                                        25   2 5 Spine Package Contents  se    ar anne 25   2 6 Management PackageContenis                        5 6    25   2 7                1  5                                                         25   2 7 1 ESD Connection                                             26   2 7 2 InstallingtheCableHolder                                     34   2 7 3 Installing the Chassis                                         36   2 7 4 Ground Connections                     
50. 1 for each management module  that get connected to    Ethernet switches  These switches must be configured to 10 100M auto negotiation   5      The SX6512 switch comes standard with a management software module for chassis  management called Mellanox Operating System  MLNX OS   MLNX OS is installed on  all SwitchX amp  based managed switch systems management modules  MLNX OS  includes a CLI  WebUI  SNMP  and chassis management features for software and IB  management software  OpenSM      You can get more information via the Mellanox MLNX OS   SwitchX   Software  WebUI User s Manual or the Mellanox MLNX OS   SwitchX   Software User Manual     The managed switch system includes the following software components     Embedded Subnet Manager  SM     Chassis manager and system BIST    SNMP agent  3rd party tool integration    GUI    Remote logging  e SSH telnet  e Secured access in band and out band      IPv4 IPv6 network stack  The chassis manager will give the user access to     Switch temperatures    Power supply voltages    Fanunit information    Power unit information    Flash memory    Monitoring of     AC power to the PSUs    DC power out from the PSUs    chassis failures    querying for     switch serial numbers    revisions    software version    SwitchX   FW version      Switch temperatures    Mellanox Technologies 75    O om       InfiniBand FDR Switch Platform Hardware User Manual      The manager also has the ability to burn new firmware and upgrade software on the  
51. 5 120 8  Chassis fans 163 3 188 2  Management module 17 6 25 9                   Table 19 assumes the QSFP cable power consumption specified in Table 20  Please note  that QSFP module power is related to the module itself and is not referenced to AC  plane    Table 20   QSFP Cable Power Consumption                QSFP Cable Type Typical  W  Maximum  W   Active 1 5 1 7  Optical 1 7 2 0                To calculate the total power consumption of the switch system at a certain configuration   fill out Table 21 in the following manner     1  Inthe Power column fill in the desired typical or maximum values   Be careful not to mix FDR and FDR10 power numbers for the particular calculation     2  In the Quantity column  fill in the desired configuration   Please note that the number of fans is not configurable and is always 1     3  Get the total power per each FRU by multiplying values in adjusted columns in the  same row     4  Get the total switch system power consumption system power by summing up all  multiplication products     Table 21   Calculating Total Switch System Power Consumption    Part Quantity Power Quantity x Power    IB FDR or FDR10 leaf with passive cables       IB FDR or FDR10 leaf with active cables                      Mellanox Technologies 87        InfiniBand FDR Switch Platform Hardware User Manual      Table 21   Calculating Total Switch System Power Consumption       Part Quantity Power Quantity x Power       IB FDR or FDR10 leaf with optical cables       
52. 94  III    1 1 2 Management Module MAC    Each management module has a label with its MAC address  See Figure 3 for the loca   tion of this label     Figure 3  Management Module MAC Address Location  MAC address location    RST PSU SFANS LFANS Mester mE  MAC         A I    1 1 3 Product Physical Specifications and Power            The switch ships in a minimum base configuration plus additional modules depending on  the chosen customer configuration  Optional modules included       Leafboards    Management modules      Spine boards    Mellanox Technologies 14        InfiniBand FDR Switch Platform Hardware User Manual      The following figure shows the connector and spine sides fully populated     Figure 4  SX6512 Switch Views       Spine Side    FRONT SIDE ORCA SX6512    Up to 4 power supply units    6 spine modules       4 leaf fan modules       12 leaf modules        2 management modules       1    Mellanox Technologies 5        InfiniBand FDR Switch Platform Hardware User Manual      1 2 Features List      216 FDR  56Gb s  InfiniBand ports in a 9U switch       24 2 Tb s aggregate data switching capacity with ultra low latency    IBTA 1 3 and 1 2 1 compliant     SDR DDR QDR FDR10 FDR link speed   e NN power supply     Congestion control       Adaptive routing      Port mirroring      Chassis High Availability     sMB High Availability    1 3 InfiniBand FDR and FDR10 Overview    The Mellanox SX6512 switch system supports FDR  standard InfiniBand data rate   where each lane 
53. EE Directive 2002 96 EC m  ssen alle elektrischen und elektronischen  Abfallger  te  EEE  separat gesammelt und nichit mit normalem Haushaltsm  ll ensorgt  werden     Dieses Produkt und alle seine Teile in verantwortungsvoller und umweltfreundlicher  Art und Weise entsorgen     Mellanox Technologies 109       Rev 1 3       G7 Advertencias de seguridad de instalaci  n  Spanish     1  Instrucciones de instalaci  n    Antes de conectar el equipo a la fuente de alimentaci  n  leer todas las instrucciones de  instalacion        2  Lesi  n corporal a causa de peso     Recurra a suficientes personas para levantar este producto sin    A se                                 lt 40 Ibs 40   70 lbs 70   121 Ibs  gt 121 Ibs   lt 18 kgs 18   32 kgs 32   55 kgs  gt 55 kgs    3  Equipos pesados    mec  nico  para evitar lesiones     4 Dado que el equipo es pesado  se debe mover   nicamente mediante un elevador    4  Riesgo de descarga el  ctrica      Riesgo de descarga el  ctrica    Con el m  dulo del ventilador quitado  se obtiene acceso a las clavijas de alimentaci  n  desde dentro de la cavidad del m  dulo    NO introducir herramientas ni partes del cuerpo en la cavidad del m  dulo del ventila   dor        5  Sobretemperatura    No se debe utilizar el equipo en un   rea con una temperatura ambiente superior a la  m  xima recomendada  45  C  Adem  s  para garantizar una circulaci  n de aire adec   uada  se debe dejar como m  nimo un espacio de 8 cm  3 pulgadas  alrededor de las  aberturas de
54. IF  ADVISED OF THE POSSIBILITY OF SUCH DAMAGE     Mellanox    TECHNOLOGIES    Mellanox Technologies   350 Oakmead Parkway Suite 100  Sunnyvale  CA 94085   U S A    www mellanox com   Tel   408  970 3400   Fax   408  970 3403    O Copyright 2015  Mellanox Technologies  All Rights Reserved     Mellanox    Mellanox logo  Bridge XQ  CloudX logo  Connect IB    ConnectX    CoolBox    CORE Direct    GPUDirect     InfiniHost    InfiniScale    Kotura    Kotura logo  Mellanox Federal Systems    Mellanox Open Ethernet    Mellanox  ScalableHPC    Mellanox Connect Accelerate Outperform logo  Mellanox Virtual Modular Switch    MetroDX    MetroX     MLNX OS    Open Ethernet logo  PhyX    SwitchX    TestX    The Generation of Open Ethernet logo  UFM    Virtual  Protocol Interconnect    Voltaire   and Voltaire logo are registered trademarks of Mellanox Technologies  Ltd     Accelio     CyPUTM  FPGADirect     HPC XTM  InfiniBridgeTM  LinkX     Mellanox Care     Mellanox CloudXTM  Mellanox  Multi Host     Mellanox NEOTM  Mellanox PeerDirect     Mellanox Socket Direct     Mellanox Spectrum     NVMeDirectTM   StPUTM  Spectrum logo  Switch IBTM  Unbreakable LinkTM are trademarks of Mellanox Technologies  Ltd     All other trademarks are property of their respective owners     2 Mellanox Technologies Document Number  3835      InfiniBand FDR Switch Platform Hardware User Manual      Table of Contents    Revision History co a                 es 9  About this Manual                   Din 10  Chapter 
55. Ibs 40   70 lbs 70   121 Ibs  gt 121 Ibs   lt 18 kgs 18   32 kgs 32   55 kgs  gt 55 kgs       product contains printed circuit boards cables and batteries  According to the WEEE  Directive 2002 96 EC  all waste electrical and electronic equipment  EEE  should be  Ad collected separately and disposed of according to the directive      P This product and all of its parts are NOT to be disposed of with household waste  This    Go to the Mellanox website for detailed instructions for disassembly of the FRUs and  chassis according to the WEEE Directive     10  Dispose of these pieces in a legal and environmentally friendly way     7 1 1 Removing the Chassis    1   2     CP                 Remove the screws connecting the upper brackets to the rack     Remove the screws holding the chassis to the rack  These screws are located in the  faceplate on the spine side of the chassis     Remove the upper brackets from the chassis   Remove the lock down bars   Dispose of the Chassis in a legal and environmental way     Go to the Mellanox website for detailed instructions for disassembly of the chassis  according to the WEEE Directive     7 1 2 Removing the Bottom Shelf    1     Remove all of the bolts that are holding the shelf to the rack     Mellanox Technologies 80    ei               InfiniBand FDR Switch Platform Hardware User Manual    2  Remove the filler panels   3  Remove the shelf     4  Removeall ofthe caged nuts     7 2 Disposal    According to the WEEE Directive 2002 96 EC  al
56. Mellanox    TECHNOLOGIES    Connect  Accelerate  Outperform       216 Port InfiniBand FDR SwitchX      Switch Platform Hardware User Manual    PN MSX6512 4R  MSX6512 NR  Rev 2 5    www mellanox com       NOTE    THIS HARDWARE  SOFTWARE OR TEST SUITE PRODUCT     PRODUCT S      AND ITS RELATED  DOCUMENTATION ARE PROVIDED BY MELLANOX TECHNOLOGIES    AS IS    WITH ALL FAULTS OF ANY  KIND AND SOLELY FOR THE PURPOSE OF AIDING THE CUSTOMER IN TESTING APPLICATIONS THAT USE  THE PRODUCTS IN DESIGNATED SOLUTIONS  THE CUSTOMER S MANUFACTURING TEST ENVIRONMENT  HAS NOT MET THE STANDARDS SET BY MELLANOX TECHNOLOGIES TO FULLY QUALIFY THE PRODUCT S   AND OR THE SYSTEM USING IT  THEREFORE  MELLANOX TECHNOLOGIES CANNOT AND DOES NOT  GUARANTEE OR WARRANT THAT THE PRODUCTS WILL OPERATE WITH THE HIGHEST QUALITY  ANY  EXPRESS OR IMPLIED WARRANTIES  INCLUDING  BUT NOT LIMITED TO  THE IMPLIED WARRANTIES OF  MERCHANTABILITY  FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT ARE DISCLAIMED   IN NO EVENT SHALL MELLANOX BE LIABLE TO CUSTOMER OR ANY THIRD PARTIES FOR ANY DIRECT   INDIRECT  SPECIAL  EXEMPLARY  OR CONSEQUENTIAL DAMAGES OF ANY KIND  INCLUDING  BUT NOT  LIMITED TO  PAYMENT FOR PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES  LOSS OF USE  DATA   OR PROFITS  OR BUSINESS INTERRUPTION  HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY   WHETHER IN CONTRACT  STRICT LIABILITY  OR TORT  INCLUDING NEGLIGENCE OR OTHERWISE   ARISING IN ANY WAY FROM THE USE OF THE PRODUCT S  AND RELATED DOCUMENTATION EVEN 
57. Mellanox Technologies      Rev 2 5      7  EXEREERW BEER    AA EEE Y   MA AR  N  MARES MAREE  ABR                                                                                                          8                           BER he SH tek   LA         PSU                                                                                                                                     9  NERNERER    LA                           FH ZI NE            FAR    10  InfiniBand HAE   RK    IN  LN    InfiniBand HE REA NANE   AKA  DEERE      L  K                                            ER                      BR ZEE BR MERE                                                                                                                                                                                                                                    12                                      ARES                                                                            Mellanox Technologies 101    14                                                                                                              15  UL IZA CSA BERR                                              PEAS UL IAM CSA 29 8     82888   16  AWG                                         125                              15                                         4 5 2 BRR                                              BEA ARH AA       lt HAR gt  FR      182888   EKRANE 1 0       EEA 300 V    KA PVC 08 ER                  
58. Multiple Languages     G 1 Nordic Countries Notices    Finland     Laite on liitett  v   suojakoskettimilla varustettuun pistorasiaan     Norway     Apparatet m   tilkoples jordet stikkontakt            Sweden     Apparaten skall anslutas till jordat uttag       G2 Installation Safety Warnings  English     1  Installation Instructions    Read all installation instructions before connecting the equipment to the power source        2  Bodily Injury Due to Weight         Use enough people to safely lift this product     3  Heavy Eguipment       This eguipment is heavy and should be moved using a mechanical lift to avoid injuries     4  Risk of Electric Shock       Risk of Electric Shock      With the fan module removed power pins are accessible within the module cavity     DO NOT insert tools or body parts into the fan module cavity   5  Over temperature    This equipment should not be operated in an area with an ambient temperature exceed   ing the maximum recommended  45  C  113  F   Moreover  to guarantee proper   allow  at least 8cm  3 inches  of clearance around the ventilation openings        Mellanox Technologies 93        Rev 1 3      6  Stacking the Chassis      The chassis should not be stacked on any other equipment  If the chassis falls  it can  cause bodily injury and equipment damage     7  Redundant Power Supply Connection   Electrical Hazard    power supply  do not operate the product with the blank cover removed or not securely    This product includes a redunda
59. Spine FDR or FDR10       Chassis fans 1       Management module                      Total power       N N redundancy ONLY works with a supply voltage of 220V        Mellanox Technologies 88        InfiniBand FDR Switch Platform Hardware User Manual    Appendix E  QSFP Interface    M    Table 22   InfiniBand QSFP Connector Pinout                                                                                                          Connector    Een  A da Xi Pin Name Signal Description   1 GND  Ground  2 Tx2n  Transmitter Inverted Data Input  3 Tx2p  Transmitter Non Inverted Data Input  4 GND  Ground  5 Tx4n  Transmitter Inverted Data Input  6 Tx4p o  Transmitter Non Inverted Data Input  7 GND  Ground  8 ModSelL   Module Select  9 ResetL  Module Reset  10        Rx   3 3 V Power supply receiver  11 SCL   2 wire serial interface clock  12 SDA  2 wire serial interface data  13 GND  Ground  14 Rx3p   Receiver Non Inverted Data Output  15 Rx3n  Receiver Inverted Data Output  16 GND  Ground  17 Rxlp  Receiver Non Inverted Data Output  18 Rxln  Receiver Inverted Data Output  19 GND  Ground  20 GND  Ground  21 Rx2n  Receiver Inverted Data Output 3  22 Rx2p  Receiver Non Inverted Data Output 3  23 GND  Ground  24 Rx4n  Receiver Inverted Data Output 3  25 Rx4p  Receiver Non Inverted Data Output 3  26 GND  Ground  27 ModPrsL Module Present  28 IntL Interrupt  29        Tx   3 3 V Power supply transmitter          ellanox Technologies    89        InfiniBand FDR Switch Platform Hardware
60. The spine fan indicator LED has the following LED assignment     Table 8   Spine Fan Status LED                         LED Color LED Description  Solid Green Spine Fan is OK  Flashing Green Spine Fan needs replacing  Mellanox Technologies 65       e MAN      InfiniBand FDR Switch Platform Hardware User Manual      M    3 1 3 3    3 1 3 4    3 1 3 5    Table 8   Spine Fan Status LED       LED Color LED Description       Solid Yellow One or more of the fans in this spine is not working  Each spine has two fans in the fan module                Spine to Leaf IB Connection Status LEDs    The leaf connection status on cach spine displays the condition of the connection  between the spine and each leaf  There is a minimum of one LED per leaf per spine and a  maximum of 3 LEDs per leaf  These LEDs indicate a valid connection between a leaf  and a spine     Table 9 shows the leaf to spine status according to the LED condition     Table 9  Spine to Leaf IB Link Status                   LED Condition LED Description  Off Link is down  Solid Green Logical connection  Flashing Green Data activity  Solid Orange Physical connection                Bad Port LED  4     The Bad Port indicator is located on the left side of the spine  The following Bad Port  conditions are possible   Table 10   Bad Port LED Configurations                LED Condition Description  Off OK     No ports have received symbol errors recently  Flashing Orange Error     One or possibly more ports has just received a  s
61. U     sa m        REA                    6 2 Leaf Board    Issue 2  The power LED for the Leaf board is off   1  Make sure that all of the PSUs are showing DC OK   2  Uninstall and reinstall the Leaf board     3  When the Yellow LED is on  this indicates a fault in the board  uninstall and reinstall  the Leaf board     4  If uninstalling and reinstalling the Leaf board does not work  burn the latest FW on  the Leaf board and uninstall and reinstall the Leaf board     5  Replace the Leaf board with a new one         4 Should any of the boards shut down due to over temperature  wait 5 minutes and then  follow the procedure starting with step 2          Issue 3  The Physical link LED for the InfiniBand connector does not come        1  Check that both ends of the cable are connected   2  Checkthat the locks on the ends are secured     3  Make sure that the latest FW version is installed on both the HCA card and the  switch     4  If media adapters are used check that the all connections are good  tight  and secure   5  Replace the cable    Issue 4  The Activity indication does not come on    Check that the Subnet Manager has been started     Mellanox Technologies 77    ei e      InfiniBand FDR Switch Platform Hardware User Manual      6 3    Management Module    Issue 1  Yellow Status LED for the Chassis on the Management Module is Lit    1  Check the MLNX OS management for confirmation and possible explanation of the  alert     2  Reset the master management module by pushing t
62. ZS CISPR 22 class A  Japan  VCCI  Class A  Australia C Tick certificate  EU  IEC 60068 2 64  Random Vibration  Environmental   EU  IEC 60068 2 29  Shocks  Type I       EU  IEC 60068 2 32  Fall Test  76 4 dB A   Acoustic ISO 7779  ETS 300 753          ellanox Technologies    83           InfiniBand FDR Switch Platform Hardware User Manual      Table 17   Switch Specification SX6512  4N R       Physical       Shock and ETSIEN 300 019 2 2  1999 09                         Vibration  Scalability and Performance  Switching capacity  24 2 Tb s  Switching performance  Simultaneous wire speed any port to any port  Addressing  48K unicast addresses max  per subnet and 15 5K multicast addresses per  subnet  Leafs  Up to 12 leafs  18 ports each  De Spines  Up to 6 spine boards  All spines are needed for non blocking configuration   Capacity    Management modules  2 available 1 required for operation       Management CPU  PowerPC 460EX       Power supplies  4 power supplies standard       Leaf fans  4       Spine fans  3                A 1 EMI Certification    EMI certification on the fully populated chassis was performed with the chassis installed  in a closed two door rack using the chassis installation kit supplied by Mellanox Tech   nologies     A 2 Approved Cables    For a list of all approved cables see     http   www mellanox com related docs user manuals Mellanox approved cables pdf                   A 3 EMC Certifications  The list of approved certifications per chassis in differ
63. ailable to customers in the near  future  For details please contact Mellanox Technologies support     Leaf Board Port Connector LED Assignment    Above the ports are two LEDs one for the upper port    and one for the lower port      Each port has a single 2 color LED  Table 6 shows the link status according to the LED  condition     Table 6   Connector Physical and Logical Link Indications                      LED Condition LED Description  Off No power to the port  Solid Green Logical link up  Flashing Green Data activity     flashing speed is proportional to data transfer speed  Solid Orange Physical link up  Flashing Orange A problem with the physical link             The LED indicator  corresponding to each data port  will light orange when the physical  connection is established  that is  when the unit is powered on and a cable is plugged into  the port with the other end of the connector plugged into a functioning port   When a log   ical connection is made the LED will change to green  When data is being transferred the  light will blink green              The switch does not provide a visual means to indicate the port speed configuration  ZA  SDR  DDR  ODR  or FDR  and or the link width  1X or 4X   The speed and link    ad width configurations can be retrieved using management software     Spine Board LED Indicators    Each leaf board is connected by links to each spine module  Each spine has the following  LEDs         One status LED for the spine health   e One sta
64. al PSU is redundant and  allows for hot swapping a PSU should one fail  Connecting the PSUs to different AC  lines provides AC failover protection     When using the 1670W PSUS  the minimum complement of power supply units to start  the chassis is 2 and the chassis will continue to run at full capacity with only 2 PSUs     The system should continue to run and allow a hot swap of a defective PSU  Should  there not be enough power to keep all of the leafs running  MLNX OS   may power  down some leafs  If this happens it may be necessary to reboot the chassis once the  defective PSU has been replaced  Two simple ways to reboot is to use the reboot com   mand in the CLI or reboot through the Web GUI     The power system will divide the current consumption by the number of working PSUs   Should one of the PSUS fail  the total current consumption will then be divided by the  remaining working PSUs  When the failed PSU is hot swapped the new PSU will ramp  up and pass its share of current  so that the total current is always divided by the number  of working PSUs     1  Plug in the power cords to the PSUs     2  Plug the other end of the power cords into grounded outlets     m  A N Make sure that the outlets and circuits will not be overloaded  Spread out the load over   7 N   OC         at least two or three circuits or use a 3 phase circuit     Figure 26  Multiple Power Inlets     Electric Caution Notification  CAUTION ACHTUNG ATTENTION    Risk of electric shock and Gafahr des el
65. are and firmware updates are available to the user from the Mellanox Sup   port website  Copy the update to a known location on a Remote server within your LAN     Use the CLI or the GUI in order to perform the Software upgrade  For further informa   tion please refer to the MLNX OS user manual             earlier version than the minimum that the new version of the software can work with   then the chassis management system may require up to  45 minutes to update all of the  Da FW images in all ofthe leafs and spines        If MLNX OS is updated and the FW image in the leafs and spines of the chassis is an    Mellanox Technologies 76                InfiniBand FDR Switch Platform Hardware User Manual      6 Troubleshooting    6 1 Power Supply Unit        A If the Power supplies cannot supply enough power  the management module may shut  down the some leafs             As each PSU is plugged in  make sure that      green power LEDs on      PSU comes on   Issue 1  Ifthe AC power LED is off    Check that the power cable is the correct power cable for your country    Check that the power cable is plugged into a working outlet    Check that the power cable has a voltage within the range of 100   240 volts AC   Remove and reinstall the power cable    Check the circuit breakers to be sure that the breaker has not tripped    Check that the power cable is good  Replace the power cable     Ifthe AC power LED is green but the OK power LED is off or the FAIL LED is on      Replace the PS
66. assis with less than all PSUs      installed     Mellanox Technologies 73                InfiniBand FDR Switch Platform Hardware User Manual      M    4 1 Power Supply and Spine Board Indicator Status at Power ON    It can take up to 5 minutes to boot up the system  Turn off the system if any LEDs    remain red for more than 5 minutes     As the power is turned on  you should observe the following conditions for normal oper   ation     1  Power Supply Unit s  AC OK and DC OK indicators are ON and FAIL indicators are  OFF     2  There is a green Status LED per spine board  per leaf board  and per management  module that indicates power supplies are good     3  Spine Board indicators will display status of internal links to the installed leaf boards   All PHY links to existing leaf Boards should be ON     4  Check the Spine LEDs and make sure they coincide with Figure 61     Figure 61  Spine Side Panel Display Status Indications     1        E        STATUS PSU SPINE LEAF MNG1 MNG2    FANS FANS MASTER MASTER       5  Check the Management Module LEDs and make sure they coincide with Figure 62     Figure 62  Management Module Status Indications for Normal Operation                     rs Do ES e IN    ellanox Technologies 74    Re      InfiniBand FDR Switch Platform Hardware User Manual      5 Switch Management Tools    This chapter describes the management module and tools available for Out of Band  management of the switch system via MLNX OS         There are 2 Ethernet ports  
67. ation of the  alert     2  Make sure that there is nothing blocking the front or rear of the chassis and that the  fan modules and ventilation holes are not blocked  especially dust over the holes      3  If you find dust blocking the holes it is recommended to clean the fan unit and  remove the dust from the front and rear panels of the switch using a vacuum cleaner     4  Remove and reinstall the spine board  Make sure the mating connectors of the unit is  free of any dirt and or obstacles  See Section 2 10 3 on page 50     5  Make sure that the spine and the Leafs both have the same version of FW   6  Reburn the FW and remove and reinstall the spine     7  Replace the spine board     6 5 MLNX OS   Software    For more detailed instructions concerning MLNX OS   software see the Mellanox  MLNX OS   SwitchX   Software WebUI User   s Manual or the Mellanox MLNX OS    SwitchX   Software User Manual     Mellanox Technologies 79        InfiniBand FDR Switch Platform Hardware User Manual      7 Disassembiy and Disposal    7 1 Disassembling the Chassis                  MES ds    en    Power down the chassis    Remove all power cables    Remove all connector cables    Disconnect the ground lug from the ground post     Loosen all locking screws for the leafs  spines  and management modules in the chas   sis     Remove all leafs     7  Remove all spines     8  Remove all management modules     9     Use enough people to safely lift this product     LA                   E Li     lt 40 
68. blackout for    example  power grid High Availability will continue to keep the chassis running at full capac   ity through the secondary or backup power supply grid     With N N optional PSU grid redundancy the chassis can run on 1 2 of the full complement of  PSUs  N N allows the chassis to run on 2 PSUs supplied from one power grid while 2 are  connected to a second power grid          A With power grid A charged with current and power grid B not charged there is only  grid redundancy and not PSU redundancy           Mellanox Technologies 17     gt  gt  o      InfiniBand FDR Switch Platform Hardware User Manual      When the power drops below the required minimum due to power supply failure   MLNX OS   may power down some leafs  If this happens it may be necessary to reboot  the chassis once the defective PSU has been replaced  Two simple ways to reboot is to  use the reboot command in the CLI or reboot through the WebUI     The form is identical between the two PSU types while the 1000W PSU weighs 0 3kg  more than the 1670W PSU     Table 3  OPNs for Power Supply Units       PSU AOA  OPN Wattage Description       MTP005001 1000W Supplies N 1 redundancy                   MTP006002 1670W Supplies N N redundancy for all switch chassis at 220 Volts       Mellanox Technologies 18        InfiniBand FDR Switch Platform Hardware User Manual      2 Installation        4 This chassis can be installed in standard 19    racks that have depths between 65cm and  80cm between the vertica
69. bles  Electric cable ties are not recommended   m2    Mellanox Technologies 35        InfiniBand FDR Switch Platform Hardware User Manual      2 7 3 Installing the Chassis    Figure 17  Chassis Rails and Rail Slides       Rail slides    y N Do not use the handles on the fans for lifting or moving the chassis in the rack     1  Screw the handles onto the chassis  Use the 8 allen head screws  and the allen wrench  provided  Two handles go on the connector side and two go on the sides of the chas   sis  Do not use the locknuts  They are extras not needed for this installation     Mellanox Technologies 36        InfiniBand FDR Switch Platform Hardware User Manual      Figure 18  Installing the Handles                                                                                       Do not use the locknuts  They are extras not needed for this installation        Figure 19  Screw the Handles Onto the Chassis       These handles get installed  here     Do not use the handles on the fans for lifting or  moving the chassis in the rack           7    Mellanox Technologies 3        InfiniBand FDR Switch Platform Hardware User Manual      Figure 20  The Rails are Already Connected Onto the Chassis        lt 40 lbs 40   70 lbs 70   121 Ibs  gt 121 Ibs   lt 18 kgs 18   32 kgs 32   55 kgs  gt 55 kgs    2  Lift the chassis and slide it onto the shelf  Use a mechanical lift or enough people to  safely lift the chassis  A full chassis weighs  120 kgs an empty chassis weighs  50  kgs       
70. ck you will be using to connect the shelf  brackets  Check that both sides of the shelf are at the same level in the rack     Figure 11  Inserting the Caged Nuts for the Shelf                            Top of shelf      Bottom of shelf     Do not use this    hole for the        shelf  This hole  is for the filler    panel     4  Insert 2 caged nuts for the filler panel     5  Using two of the bolts for each rail slide  install the rail slides onto the rack  Check  that both sides of the switch  left and right  are the same level in the rack                                Mellanox Technologies 31              lt _ lt  om      InfiniBand FDR Switch Platform Hardware User Manual      Figure 12  Connect Rail Slide to Rack Vertical support       6  Place the four bolts for the caged nuts within reach   7  Putthe shelfinto place and screw the bolts into the nuts from step 3    8  Extend the rail slides to the rack vertical support and screw them to the rack using the  2 hole washers and lock washers  See Figure 12     9  Tighten all of the screws to 7 7 Nm or 68 pound inches     10 Insert 8 caged nuts for the faceplate in the exact locations shown in  Figure 13    Inserting the Caged Nuts for the Faceplate        11  Install the filler panel directly below the shelf     Figure 13  Inserting the Caged Nuts for the Faceplate    Leaf Side  Spine Side  Place the  caged nuts Place the  here  caged nuts    here     Shelf          Mellanox Technologies 32        InfiniBand FDR Switch Pla
71. como  minimo  300 voltios nominal  con cobertura protectora aislante de PVC  El cable debe  tener un enchufe moldeado con capuch  n de 250 voltios nominal  10 A     17  Alta corriente de fuga      ADVERTENCIA  Alta corriente de fuga  Es esencial efectuar la conexi  n a tierra  antes de conectar la alimentaci  n     18  C  digos de instalaci  n    Este dispositivo se debe instalar conforme a la versi  n m  s reciente de los c  digos  el  ctricos nacionales del pais en cuesti  n  En Am  rica del Norte  el equipo se debe  instalar de acuerdo con las disposiciones vigentes del Codigo El  ctrico Nacional de los  EE UU  y del C  digo El  ctrico de Canad       19  Interconexi  n de unidades    Los cables para la conexi  n con las interfaces RS232 y Ethernet de la unidad deben  estar homologados por UL tipo DP 1 o DP 2   Nota  cuando residen en circuito no de  tipo LPS    Protecci  n contra sobrecargas  Al cableado del edificio se debe incorporar un disposi   tivo de protecci  n contra sobrecargas de circuito derivado  de f  cil acceso  con una  corriente nominal de 20 A        112 Mellanox Technologies       Rev 2 5    20  No utilizar el conmutador como estante ni como espacio de trabajo    Cuidado  Equipos montados en deslizadores o rieles no se deben utilizar como estantes  ni como espacio de trabajo  La finalidad de los rieles no es deslizar la unidad hacia  afuera del bastidor  Sirven solo para la instalaci  n permanente en el lugar de destino  final  no para fines de servicio o
72. connector  This interface is USB 2 0     Mellanox Technologies 71      InfiniBand FDR Switch Platform Hardware User Manual       3 4 5 Reset  RST    The Reset button resets the chassis management module when the button is pushed   When the button is held down for 15 seconds the management module is reset and the  password deleted     DO NOT use a sharp pointed object such as needle or push pin for pressing the Reset  button  Sharp objects can cause damage  use a flat object such as a paper clip                                                  This button resets the CPU of the management module  A quick push of this button per   forms this reset  When the reset button is pushed on the master management module this  management module is reset becoming the slave and the other management module  becomes the master  If there is only one management module in the chassis all of the  leafs and ports are reset by bringing them down and powering them up when the reset  button is pushed  When the button is held down for 15 seconds the management module  is reset and the password is deleted  You will then be able to enter without a password  and make a new password for the user    admin        2    Mellanox Technologies 7        InfiniBand FDR Switch Platform Hardware User Manual    4 Chassis Power Up    A  A N Before starting any procedure on the SX6512 system put an ESD prevention wrist     Y strap on your wrist and connect to the SX6512 chassis     With N 1 PSU redundancy the chassis 
73. cting a Leaf Board    Each leaf board has a ejector handle that locks the board in place and serves as a lever for  seating or extracting  see Figure 32      1  Run the shut down command    no power enable  lt module gt      For example to shut  down leaf 16 run the command below     switch  master   config    no power enable L16    2  Disconnect all cables connected to the leaf   3  Push the ejector handle to unlock the ejector from the chassis     4  Open the ejector until it is 45 degrees from the leaf     ellanox Technologies 47    ad A       InfiniBand FDR Switch Platform Hardware User Manual    Figure 32  Ejector Handle         Ejector handle  gt  gt     Pull the leaf out of the chassis       Push the ejec   tor handle         5  Pull out the module half way through the guiding rails using the ejector handle   6  Lock the ejector handle   7  Hold the body of the leaf on both sides and remove it from the chassis     The board is short  therefore do not let go of it while sliding it out     Figure 33  Leaf Release  Push here to release the ejector handle Pull the ejector handle to remove the leaf    c UP 2    X  A       A vo     vo      Vu UA Vs UA Vs       2 10 2 2 Inserting a Leaf Board    When hot swapping any of the units  it is necessary to wait 1 minute after removing  the defective part before inserting the new part  This is necessary so that the manage   ment module will start a new cycle checking through the leafs and spines for the FW   versions        To insert
74. d for any possible customization as    follows     Take the weight of a chassis with the following FRUs installed     e All fans modules      All power supplies    The weight of the SX6512 chassis configured above is kg     To this add the weight of installed FRUs     Spines       Leafs     Leaf blanks      Management modules    Fill in the Table 18 to calculate the weight of your system     Table 18   Switch System Weight Calculation       Number of FRUs FRU Type    Weight of 1 FRU    Total Weight   FRU Type       Chassis as shipped         of Spines      377           of leafs      2 76           011081 blanks      0 764           of management modules      3 15         Total                      This total is in kilograms  Multiply the total by 2 2 to get the total weight in pounds     Mellanox Technologies    86      E      InfiniBand FDR Switch Platform Hardware User Manual      Appendix D  Calculating the Power of a Chassis    To calculate the power consumption of a chassis add the power of the fans  spines  leafs   and management modules   Table 19   Power Consumption of Chassis Parts                                     Part Typical  W  Maximum  W    IB FDR leaf with passive cables 109 5 111 4  IB FDR leaf with 18 active cables 150 6 157 9  IB FDR leaf with 18 optical cables 156 1 166 2  Spine FDR 128 6 135 2  IB FDR10 leaf with passive cables 84 4 97 1   IB FDR10 leaf with 18 active cables 125 5 143 6  IB FDR10 leaf with 18 optical cables 131 0 151 8  Spine FDR10 103 
75. dule is bad   Check the spines for a flashing green fan LED                 3 1 5 3 Management Module L  FANS LED Indicator    The management module L  FANS indicator should be green   Table 15   Management Module L Fan LED Configurations                         LED Condition Description  Green OK     All Chassis Leaf fans are working at configured speed   Red Error     One or more of the leaf fans for the chassis is bad  Check each  chassis fan for a red LED   Mellanox Technologies 69    Xi        InfiniBand FDR Switch Platform Hardware User Manual      3 1 5 4 Management Module MASTER LED Indicator    Table 16   Management Module MASTER LED Configurations                      LED Condition Description  Green This management module is the master   Off This management module is the slave        3 1 6 Port Connector Interfaces    3 2    3 3    3 4    The connector side of the switch has 12 leaf boards and each leaf board has 18 QSFP  ports  The ports on each leaf board are placed in two rows  9 ports to a row  The ports are  labelled as shown in Figure 57  The bottom row ports are flipped from the top row  See  Figure 58     Figure 57  Port Numbering       Figure 58  Top and Bottom Ports          Air Flow    These switches come with the air flow pattern of air entering through the spine side and  exiting through the connector side     QSFP Cable Power Budget Classification   All SX6512 QSFP switches are designed for active cables with a max power per module  of 2 0W  This is p
76. dule is not functioning the status LED  on the fan will light up     Each spine has an individual fan module that contains two individual fans  Should a sin   gle fan fail the Fan Status LED on the spine and the S  Fan LED on the management  module will light  indicating the necessity to replace the fan module  Air flow through  the spines is independent of the air flow through the leafs     2 10 4 1 Leaf Fan Module    There are 4 leaf fan modules found on the spine side     Figure 43  Leaf Fan Locations on the Chassis                   Extracting the Leaf Fan Module  1  Push and hold the blue latch release  See Figure 44   2  Slowly pull out the fan module using the handle     Mellanox Technologies 55        InfiniBand FDR Switch Platform Hardware User Manual      Figure 44  Leaf Fan Module Extraction         Handle       Latch  Release    Inserting the Leaf Fan Module    When hot swapping any of the units  it is necessary to wait 1 minute after removing  the defective part before inserting the new part  This is necessary so that the manage   ment module will start a new cycle checking through the leafs and spines for the FW  versions     1  Make sure the fan module is oriented correctly top side up  Confirm that the location  of the connector in the chassis will line up with the connector in the fan module     2  Slowly slide in the new leaf fan module        If the fan module stops before it goes in all of the way it is inserted incorrectly or it  may be for the other side
77. dulo della ventola     5  Temperatura eccessiva    AN Questa apparecchiatura non va utilizzata in un   area con una temperatura ambiente  y  V superiore a quella massima consigliata  45   C  113   F   Inoltre  per assicurare un    N flusso d aria adeguato  lasciare almeno 8 cm  3 pollici  di spazio attorno alle aperture         di ventilazione     6  Impilare lo chassis      Ku  i  te se ne bi trebalo slagati na drugu opremu  Ako ku  i  te padne  mo  e izazvati tje   lesne ozljede i o  te  enje opreme     7  Collegamento di alimentazione ridondante   Pericoli elettrici    installato  di uno spazio vuoto  Qualora l alimentatore non sia installato  non utilizzare    l Questo prodotto    dotato di un alimentatore ridondante o  qualora esso non sia    il prodotto con il coperchio rimosso o non fissato correttamente     8  Prese di alimentazione multiple  Rischio e pericolo di scosse elettriche   i Gli alimentatori sono tutti indipendenti   Scollegare tutti gli alimentatori per assicurarsi che il commutatore non sia sotto  tensione    9  Durante i temporali  pericolo di scosse elettriche      Durante i temporali  non effettuare interventi sull   apparecchiatura e non collegare     scollegare i cavi        10  Collegamento scollegamento del cavo di rame InfiniBand    I cavi di rame InfiniBand sono pesanti e non flessibili  Di conseguenza  vanno  collegati o scollegati con cura dai connettori  Per avvertenze istruzioni speciali        rivolgersi al produttore di cavi     124 Mellano
78. e PSUs may be extracted without bringing down the system    gt  To extract a PSU     1  Determine which AC connector on the connector side of the chassis corresponds to  the defective PSU     2  Remove the power cord from the power supply unit  Note which power cord it is  according to the AC numbering     Figure 28  Power Cord Numbering                                                                                                                               Mellanox Technologies 45           InfiniBand FDR Switch Platform Hardware User Manual      Figure 29  PSU Locations        gt     PIA                  A           Fan  1        e AM e so      eo e  Mellanox  9 se es ee        O    Fan  3 Fan LES   O           050000000  000550000    550055060  000550000          5500550060  000550000       050050000  0005560000    095559906  000905000    4 A                         000900000      0090005500 pal     000500000  LI                                             On the spine side of the chassis  remove the cover to the power supply unit for the  non working PSU  Odd numbered PSUs are on the left side and even numbered PSUs  are on the right side facing the spines There are four phillips head screws for the  cover plate     Figure 30  Power Supply          e DE 5 AC Latch      DD  SM             Handle                                                       Grasping the handle with one hand  push the black latch release while pulling the  handle outward  As the PSU unseats  the
79. e in the management board  If you feel resistance     Y N remove the management and double check both the chassis and management for any  damage        8  Catch the hooks onto the vertical bar of the chassis and push the ejector handle shut   9  Lock the ejector handles onto the board     the master management module CPU and only then configure the slave  By default the  master CPU is the top management module  For further information on the master and       slave roles  see the MLNX OS   Software UM section    High Availability           On switch systems with dual management systems  first connect the cable and configure            gt  All management modules in the chassis must go through an initial configuration proce   dure  See the Installation Guide for the initial configuration procedure   A     Mellanox Technologies 59    om       InfiniBand FDR Switch Platform Hardware User Manual      2 10 6 Switch Shut Down Procedures    To shut down the chassis run the following command twice  once for each MM      Reload halt  noconfirm     A                The chassis cannot be restarted remotely        To restart the chassis you must physically go to the switch and unplug all of the       1 V power cords to the chassis and then replug in all of the power cords to the chas       BB       The first time you run the command it shuts down the master management module and  the second time shuts down the slave management module     To shut down a leaf run the following command   no p
80. ed on different generations of chip         Do not install InfiniScale IV based replacement parts within a SwitchX   based chas   sis and vice versa  All Replacement modules must be consistent with the Chassis fam         ily and switch chip generation     When hot swapping any of the units  it is necessary to wait 1 minute after removing the  defective part before inserting the new part  This is necessary so that the management  module will start a new cycle checking through the leafs and spines for the FW ver   sions        Each spine has a pair of ejectors that lock the board in place and serve as levers for seat   ing or extracting  see Figure 37      Management board  1 is connected to spine board  1  and management board  2 is con   nected to spine board  2  When a slave management board is not installed or not  working  the spine board connected to the master management board cannot be  hot swapped  All of the spine boards can be hot swapped when two management boards  are installed and working        4   V When more than one spine slot is empty always insert the lowest spine board first  then  4   work your way up         A       A N If you need to replace the bottom spine and it does not go in  try removing one or two    NS spines above it and then insert the spines from the bottom up   GC    Mellanox Technologies 50    e mm       InfiniBand FDR Switch Platform Hardware User Manual    2 10 3 1 Extracting a Spine Board    When a slave management board is not installed
81. ektrischen Schocks  Risque de choc et de danger  energy hazard  Entferrnen des Netzsteckers e   lectriques  Le de   branchment  The PSUs are all independent   elnes Netzteils spannungsfrei  d   une seule alimentation stabi     Um alle Einhieten spannungsfrei     lise e ne de   branch uniquement    Disconnect all power supplies to zu machen sind die Netzstecker qu   un module    Alimentation  ensure a powered down state aller Netzteile zu entfernen Stabilise e   Pour isoler comple   inside of the switch platform  tement le module en cause  Il    faut de  brancher toutes les ali   mentations stabilise es     ellanox Technologies 42         InfiniBand FDR Switch Platform Hardware User Manual    3  Check the Status LEDs on all of the management modules and confirm that all of the  LEDs show status lights consistent with normal operation     Any yellow or red status LEDs on any ofthe management modules is cause for con   cern and must be dealt with immediately     4  Check that none ofthe LEDs on the spines are yellow     It can take up to 5 minutes to boot up the system  Turn off the system if any LEDs  remain red for more than 5 minutes     5  Check that the leaf status LEDs  fan status LED  and spine status LED in the spines  are all green     maximum number of connections per leaf  is less than 36 then some ofthe leafto spine    The maximum number of connections from each leaf is 3 Ifthe  number of leafs x the  MA connection LEDs may be OFF     Figure 27  Spine Module         
82. elettriche ed  elettroniche  RAEE  vanno raccolti separatamente e non smaltiti nei normali rifiuti  domestici   Smaltire questo prodotto e tutte le sue parti in modo responsabile e rispettoso  dell   ambiente   LA    21  Limitazioni relative all   alimentazione per la Norvegia    y     Questa apparecchiatura    progettata esclusivamente per il collegamento a un sistema di    N alimentazione TN e a un sistema di alimentazione IT     126 Mellanox Technologies       Rev 2 5    G12 Montaj G  venlik Uyar  lar    T  rk  e   1  Montaj Talimatlar      Ekipman   g     kayna    na ba  lamadan   nce t  m montaj talimatlar  n   okuyun        2  A    rl  k Nedeniyle Fiziksel Yaralanma    Bu   r  n   g  venli bir   ekilde kald  rabilmek i  in yeterli say  da insandan yard  m al  n          lt 40 Ibs 40   70 Ibs 70   121 lbs  gt 121 Ibs   lt 18 kes 18   32 kc3 32   55 kgs  gt 55 kge    3  A    r Ekipman      Bu ekipman   ok a    rd  r ve yaralanmalar     nlemek i  in ekipman  n mekanik asans  r  kullan  larak ta    nmas   gerekir     4  Elektrik   arpmas   Riski     Bu ekipman    nerilen maksimum ortam s  cakl      n   a  an alanlarda calistirilmamalidir   45  C  113   F   Ayr  ca  d  zg  n hava ak       sa  lamak i  in havaland  rma deliklerinin  etraf  nda en az 8 cm  3 in    a    kl  k b  rak  lmal  d  r        5           s  nma    y  Bu ekipman    nerilen maksimum ortam s  cakl      n   a  an alanlarda calistirilmamalidir   A V 45   C  113   F   Ayr  ca  d  zg  n hava ak       sa  lama
83. emove and reinstall the problematic fan unit  Make sure the mating connector of the  new unit is free of any dirt and or obstacles  See Section 2 10 4 on page 55     6  Replace the Leaf fan module     YN Replace defective leaf fan modules as soon as they are identified     Should any of the boards shut down due to over temperature  follow the procedure  starting in step 2    Issue 3  Yellow LED for the Spine Fan on the Management Module is Lit    1  Check the MLNX OS management for confirmation and possible explanation of the  alert     Mellanox Technologies 78        InfiniBand FDR Switch Platform Hardware User Manual      2  Determine which spine has a defective fan by checking the Fan LEDs on all of the  spines     3  Make sure that there is nothing blocking the front or rear of the chassis and that the  fan modules and ventilation holes are not blocked  especially dust over the holes      4  If you find dust blocking the holes it is recommended to clean the fan unit and  remove the dust from the front and rear panels of the switch using a vacuum cleaner     5  Remove and reinstall the fan unit of the spine  Make sure the mating connector of the  new unit is free of any dirt and or obstacles  See Section 2 10 4 on page 55     6  Replace the spine fan module     LA Replace defective spine fan modules as soon as they are identified     6 4 Spine Board    Issue 1  The yellow LED on the Spine board is lit     1  Check the MLNX OS management for confirmation and possible explan
84. ent Parts Ordering Numbers    Table 23   Replacement Parts Ordering Numbers                                                    Part Description OPN  Power supply unit PSU 1000W for Modular Switch 1  Family  Power Supply unit PSU 1670W for Modular Switch  MTP006002  Family  Power supply blank MTM005001  Leaf board unit 18 port FDR MSX6001FS  Leaf board unit 18 port FDR10 MSX6001TS  Modular Switch Family  Leaf   Blank MTM005004  Spine board unit for FDR system MSX6002FLS  Spine board unit for FDR10 QDR system MSX6002TBS  Spine board blank MTM005002  PPC460 Management Module MSX6000MAR  x86 Management Module MSX6000MBR  Modular Switch Family  Management   Blank MTM005003  Rack Installation Kit for IS5600 SX6536 Series MTR005600  SX6536  SX6518  SX6512 MSX 6506 Modular Switch  MTF005005    Series Spine Fan Unit             DB9 to RJ45 Harness HAR000028  Power cord 250V 15A 2 0M C14 to C13 ACC000334  Power cord 125V 15A 2 0M C14 TO C13 ACC000242       Power cord Type B for USA  Canada  Mexico  Taiwan  ACC000204       Power cord Type H for Israel ACC000205       Power cord Type E F for Sweden  France  Germany   ACC000207  Netherlands  Russia                            Power cord Type G for UK ACC000208  Power cord Type D for India ACC000209  Power cord Type I for China ACC000210  Power cord Type J for Switzerland ACC000211  Power cord Type B for Japan ACC000212  Power cord Type I for Australia ACC000213    2    Mellanox Technologies 9        Rev 2 5    Appendix G  Safety Warnings  
85. ent regions of the world is located  on the Mellanox Website at     http   www mellanox com related docs user manuals Regulatory and Compli   ance Guide pdf  EMC Statements are also in the Regulatory and Compliance Guide                    Mellanox Technologies 84        InfiniBand FDR Switch Platform Hardware User Manual    Appendix B  Thermal Threshold Definitions    There are three thermal threshold definitions for the SwitchX   switch device which  impact the overall switch system operation state  Warning  Critical and Emergency     1  Warning     100  C  On managed systems only  When the SwitchX   device crosses the 100  C threshold  a    Warning Threshold message will be issued by the MLNX OS management SW  indicat   ing to system administration that the switch has crossed the Warning threshold     Note that this temperature threshold does not require nor lead to any action by hardware   such as switch shutdown      2  Critical     120  C    When the SwitchX   device crosses this temperature  the firmware will automatically  shut down the device     3  Emergency     130  C    In case the firmware fails to shut down the SwitchX   device upon crossing the Critical  threshold  the SwitchX   device will auto shutdown upon crossing the Emergency   130  C  threshold     Mellanox Technologies 85       A      InfiniBand FDR Switch Platform Hardware User Manual    Appendix C  Calculating the Weight of a Customized    Chassis    The weight of a customized chassis can be calculate
86. f       momo     m ma        iti A           LE un              Mellanox Technologies 53    ST  e EA       InfiniBand FDR Switch Platform Hardware User Manual      Figure 40  Intact vs Defected Middle Signal Connectors       4  Check power connector   s integrity  Look for any damage on the power connector  casing or blades damage  or any deviations from the pass criterion shown in  Figure 41        5  Note the following sticker placed on the top of the spine board     Figure 42  Spine Board Insertion Caution    A INSERT SLOWLY A    USE EJECTOR HANDLES ONLY         4    Mellanox Technologies 5         InfiniBand FDR Switch Platform Hardware User Manual    6  Start with the ejector handles fully open  that is  at 45 degrees to the front panel of the  spine     y N Do not use the fan FRU handle to insert the spine board     7  Holding the spine by its sides  carefully set the spine board into the chassis     8  Using only the ejector handles  slowly slide the board into the chassis until the hooks  reach the vertical bar     Do not apply excessive force to slide in the spine board  If you feel resistance  remove  the spine and double check both the chassis and spine for any damage     9  Catch the hooks onto the vertical bar of the chassis and push the ejector handle shut   10  Lock the ejector handles onto the board     2 10 4 Fan Modules    There are four fan modules on the chassis for the leafs  They are located on the spine  side  along the top of the chassis  When a fan mo
87. g  w  hlen Sie ein Netzkabel  das international  harmonisiert und der Aufschrift   lt HAR gt       3   Leiter  mindestens 0 75 mm2 Draht  bewertet mit 300 V  mit einem PVC Mantel  isoliert  Das Kabel muss eine angespritztem Stecker bewertet bei 250 V  10 A      16  Hoher Ableitstrom    WARNUNG  Hohe Ableitstrom  Earth Verbindung  bevor Sie die Verbindung von  wesentlicher Bedeutung werden     17  Installationscodes    Dieses Ger  t muss installiert sein  entsprechend auf die neueste Version des Landes     National Electrical Code         Nordamerika  m  ssen        bereinstimmung mit den gel   tenden Vorschriften in der US amerikanischen National Electrical Code und dem  Canadian Electrical Code     18  Verbindung der Ger  te untereinander    Kabel f  r den Anschluss an das Ger  t RS232 und Ethernet Schnittstellen m  ssen UL  zertifiziert Typ DP 1 oder DP 2   Hinweis   wenn nicht mit Wohnsitz in LPS Schal   tung          berstromschutz  Eine leicht zug  ngliche Auflistung Abzweigleitung   berstrom   Schutzeinrichtung 20 A bewertet werden m  ssen in dem Geb  ude Verkabelung     19  Switch nicht als Regal oder Arbeitsplatz nutzen    Achtung  Auf Schieber Schienen montiertes Ger  t ist nicht als Regal oder Arbeitsbere   ich zu nutzen  Die Schienen sind nicht daf  r bestimmt  die Einheit aus dem Gestell  weg zu ziehen  Sie sind nur f  r die permanente Installation an einem endg  ltigen Stan   dort gedacht  nicht f  r Instandhaltung und Wartung     20  WEEE Direktive    Gem     WE
88. gement modules     14  Install any power supply units  and fan units removed at the start of the installation  procedure     15  Insert all leafs that you plan to use  in      chassis  Start at the bottom of the chassis  and work your way up     16  Insert the first two spines in the top two slots   17  Insert the rest of the spines from the bottom of the chassis up to slot  3   18  Insert thermal blanks in unused leaf slots to maintain balanced air flow     19  Tighten all leaf and spine mounting screws     ellanox Technologies 40        InfiniBand FDR Switch Platform Hardware User Manual      2 7 4    20 Connect the power cords to the PSUS     21 Check the Status LEDs and confirm that all of the LEDs show status lights consistent  with normal operation     Warning  Any yellow status LEDs is cause for concern and must be dealt with imme     diately   LA It can take up to 5 minutes to boot up  during which time the status LED may indicate  flashing green     22  You can start connecting all of the cables to the switch     Ground Connections    Make sure to connect the ground post to a valid electrical ground  Use a grounding lug  and a ground wire of sufficient capacity to safely convey a potential discharge  The  grounding post is M 6 with Imm pitch threads  A ground wire of AWG 6 or 4mm diam   eter is recommended for grounding this device  The chassis is concurrently grounded  through each of the PSUS  Only connect the PSU cords to properly grounded outlets  Do  not rely on
89. genommenem Ventilatormodul sind die Stromkontakte in der Modulvertiefung  zug  nglich    Es d  rfen KEINE Werkzeuge oder K  rperteile in die Vertiefung des Ventilatormoduls  gelangen        5    bertemperatur    A Dieses Ger  t sollte nicht in einem Bereich mit einer Umgebungstemperatur   ber der  A   maximal empfohlenen Temperatur von 45  C  113  F  betrieben werden  Es ist ein Luft       strom von 200 LFM bei maximaler Umgebungstemperatur erforderlich  AuBerdem    sollten mindestens 8 cm  3 in   Freiraum um die Bel  ftungs  ffnungen sein  um einen    einwandfreien Luftstrom zu gew  hrleisten     6  Stapeln des Chassis      Das Chassis sollte nicht auf andere Ger  te gestapelt werden  Wenn das Chassis herunt   erf  llt  kann es zu Verletzungen und Besch  digungen an Ger  ten f  hren     7  Mehrere Stromeing  nge    Risiko eines Stromschlags und Stomgefahr     Alle Stromversorgungseinheiten sind unabh  ngig   Trennen Sie alle Stomversorgungen  um einen abgeschalteten Zustand im Inneren der    Switch Plattform sicherzustellen     Mellanox Technologies 107      Rev 1 3      8  Bei Gewitter   Elektrische Gefahr    Arbeiten Sie w  hrend eines Gewitters und Blitzschlag nicht am Ger  t  schlie  en Sie  keine Kabel an oder ab     9  Anschlie  en Trennen von InfiniBand Kupferkabel       N InfiniBand Kupferkabel sind schwer und nicht flexible  Deshalb m  ssen sie vorsichtig      an die Anschl  sse angebracht bzw  davon getrennt werden  Lesen Sie die speziellen  y Warnungen und Anleitu
90. guration    The switch platform uses 10U of rack space in a standard 19  rack  9U for the chassis  and 1U for the shelf  The switch ships from the factory with mounting holes on the spine    Mellanox Technologies 25    NN em      InfiniBand FDR Switch Platform Hardware User Manual      side  There are upper brackets to connect the leaf side to the rack near the top of the chas   sis  The weight of the switch is supported from underneath the unit by the shelf     This chassis can be installed in standard 19    racks that have between 65cm and 80cm  between the vertical supports of the rack  Make sure that a fully populated rack including  cables will have sufficient air flow for cooling          Choose a rack which is able to support the mechanical and environmental characteris   tics of a fully populated switch chassis   5      2 7 1 ESD Connection  Before starting any procedure on the SX6512 switch system     1  Put an ESD prevention wrist strap on your wrist  and make sure there is good contact  between your body and the strap     2  Plug the other end of the wrist strap to a valid ground  Make sure that this is a tight  fit     2 7 1 1 Installation ProcedureRequirements    You will need        2 phillips screwdriver    3 phillips screwdriver    agrounding lug   ground wire to properly ground the chassis    Y The installation will be much easier with a power screwdriver     Y It is recommended to use AWG6 or 4mm diameter wire for grounding purposes     It is recommended to 
91. have at least two people for the duration of the installation proce   dure  Use a mechanical lift to raise this chassis  If not  use enough manpower to ensure  the safety and wellbeing of all of the people involved in the installation        Mellanox Technologies 26         InfiniBand FDR Switch Platform Hardware User Manual      2 7 1 2 Installation and Cable Management Kit Parts    Parts for installing the shelf      1 shelf   8 M6 bolts for the caged nuts    4 caged nuts e 2 Shelf rail slides    4 lock washers   2 long 2 hole flat washers    Parts for installing the chassis    e 2 chassis rail slides e 4 handles   e 8    5 pan head bolts e 8 allen head screws     2 flat 4 hole metal spacers   1 allen wrench     8 lock washers   4 lock nuts for handles  These nuts are not to be used     8 caged nuts for the faceplate e 8 M6 bolts for the caged nuts  8 for the faceplate    Parts for installing the filler panel      1 Bottom filler panel e 2 M6 bolts    2caged nuts M6    Parts for installing the cable manager      RH cable holder   1 LH cable holder    12 caged nuts M6 e 12 M6 bolts    6 cable holder shelves    You will need 10 U of space in the rack  Nine U for the chassis and one U for the shelf     Figure 5  Shelf Installation Kit Parts    Angled Shelf  Bracket   Rail  M6 X 16       Rail Slide    M6 X 12 bolts  caged nuts and  split lock washers    Mellanox Technologies 27          InfiniBand FDR Switch Platform Hardware User Manual    Figure 6  Chassis Installation Parts 
92. he rest button  If you have two  management modules installed this will convert the master management module to  the slave and convert the slave to the master     AN If there is only one management module in the chassis all of the leafs and ports       are reset by bringing them down and powering them up when the management  y module is removed        Make sure the S Fans and L Fans LEDs are green   Make sure that the spine and the leafs both have the same version of FW     Reburn the FW and remove and reinstall the management module     NN aa    If you are running the chassis with only one management module  remove and rein   stall the management module  Make sure the mating connectors of the unit are free of  any dirt and or obstacles  See Section 2 10 5 on page 57     7  If you are running the chassis with only one management module  replace the man   agement module     Issue 2  Yellow LED for the Leaf Fan on the Management Module is Lit    1  Check the MLNX OS management for confirmation and possible explanation of the  alert     2  Make sure that there is nothing blocking the front or rear of the chassis and that the  fan modules and ventilation holes are not blocked  especially dust over the holes      3  If you find dust blocking the holes it is recommended to clean the fan unit and  remove the dust from the front and rear panels of the switch using a vacuum cleaner     4  Determine which fan module is problematic by checking the status LED on each fan  module     5  R
93. iale pentru a se asigura ca sistemul r  m  ne stabil  In general  trebuie s      y umpleti rack ul cu echipamente incep  nd de jos   n sus     12  Instalarea echipamentului    Acest echipament trebuie s   fie instalat    nlocuit   i sau depanat numai de c  tre personal  instruit   i calificat        13  Eliminarea echipamentului    Eliminarea acestui echipament trebuie s   se realizeze   n conformitate cu toate legile   i  regulamentele na  ionale           118 Mellanox Technologies      Rev 2 5      15  Codurile ed instalare    Acest dispozitiv trebuie s   fie instalat   n conformitate cu ultima versiune a codurilor  electrice nationale ale     rii   n cauz    Pentru America de Nord  echipamentul trebuie s    fie instalat conform cerin  elor aplicabile din Codul electric na  ional al SUA   i Codul  electric canadian        16  Cordon de alimentare electric     nregistrat UL   i certificat CSA    A Pentru conectarea la o surs   de alimentare pentru America de Nord  selectati un cordon       de alimentare care este   nregistrat UL si certificat CSA  cu 3 conductoare   16 AWG          terminat cu o fi     turnat    cu putere nominal   egal   cu 125 V   13 A   cu o lungime de    minimum 1 5 m  sase picioare   dar nu mai lung de 4 5 m     Pentru conectarea la o sursa de alimentare in Europa  selectati un cordon de alimentare  care este armonizat la nivel international   i marcat     lt HAR gt      cu 3 conductoare  cu  minimum 2 fire de 1 0 mm  cu putere nominal   egal   cu 300 V
94. k i  in havaland  rma deliklerinin  4   etraf  nda en az 8 cm  3 in    a    kl  k b  rak  lmal  d  r     6    asi   stif    4 Sasinin di  er herhangi bir ekipman  n   zerine istiflenmemesi gerekir    asi d    erse     fiziksel yaralanmalara ve ekipmanda hasara neden olabilir     Mellanox Technologies 127      Rev 1 3      7  Yedekli G     Kayna  y Ba  lantysy  Elektrik   arpma Tehlikesi    Bu   r  n  yedekli g     kayna     veya onun yerine bo   elektrik kutusu i  erir  G     kayna      gp  i  in bo   elektrik kutusu varsa  kutunun kapa     a    kken veya tam olarak    kapat  lmam    ken   r  n     al    t  rmay  n   8    oklu G     Giri  leri  Elektrik   arpmas   riski ve enerji tehlikesi       B  t  n PSU lar  G     Kayna       niteleri  ayr  d  r   Anahtar platformundaki g  c   kapatmak i  in t  m g     kaynaklar  n  n ba  lant  lar  n      kesin     9    im  ek   Elektrik   arpma Tehlikesi      G  ky  z  nde   im  ek   akt       zamanlarda  ekipman   zerinde   al    may  n veya kablo  ba  lamay  n ya da kablo ba  lant  s   kesmeyin     10  Bak  r   nfiniband Kablo Ba  lama Ba  lant  y   Kesme    Bak  r   nfiniband kablolar a    rd  r ve esnemezler  Bu nedenle  ba  lant  lara   ok dikkatli  bir   ekilde tak  lmalar   veya     kar  lmalar   gerekir    zel uyar  lar talimatlar i  in kablo    reticinize ba  vurun        11    skele Montaj   ve Bak  m    Bu   r  n bir iskelede monte edildiyse veya bir iskele ile sunulduysa  sistemin sabit    kalmas   i  in   zel   nlemler al  
95. k to get up  To remove  disengage the lock and slowly pull the connector  away from the port receptacle     A        For a valid physical connection both ends of the cable must be connected to working  A    devices          EN          Take          to not impede the air flow through the ventilation holes next to the Infini         Band ports  Use cable lengths which allow routing horizontally around to the side of      the chassis before bending upward or downward in the rack     2 9 1 Supported Approved Cables  For a list of approved cables for this switch see the Mellanox approved cable list     http   www mellanox com related docs user_manuals Mellanox_approved_cables pdf                   2 9 2 Cable Power Classes    Chassis and switches need to be able to dissipate the heat generated by high power I O  cables and modules  The Mellanox SX65xx series chassis are rated for cables up to class  2 as per the SFF committee classification  SFF 8436 PDF      See http   www mellanox com content pages php pg cables for the cable class rating of  Mellanox cables        2 10 Hot Swap Insertion and Extraction    Before starting any procedure on the SX6512 switch system  put an ESD prevention  wrist strap on your wrist and connect to the SX6512 chassis     Do NOT mix replacement parts based on different generations of chip        Do not install InfiniScale IV based replacement parts within a SwitchX   based chas   sis and vice versa  All Replacement modules must be consistent with the
96. l supports of the rack   Ad    Installation and initialization of the chassis is a simple process requiring attention to the  normal mechanical  power  and thermal precautions for rack mounted equipment  Your  chassis comes only with the power supplies and fans pre installed  The rest of the open   ings are populated with blanks  All of the leafs  spines  and management modules come  shipped in a separate package     The chassis requires initial configuration to get the chassis and Fabric management up  and running through remote management  See the Installation Guide that is packed in the  box for the instructions to make the initial configuration     access area can be accessed only through the use of a special tool  lock and key  or        This unit is intended for installation in a Restricted Access Location  A restricted  other means of security      gt     2 1 Installation Safety Warnings    These safety warnings are in English  For French  German  Spanish  Russian  and Roma   nian see the Appendixes     1  Installation Instructions    Read all installation instructions before connecting the equipment to the power source        2  Bodily Injury Due to Weight    Use enough people to safely lift this product     LA e           lt 40 Ibs 40   70 Ibs 70   121 Ibs  gt 121 Ibs   lt 18 kgs 18   32 kgs 32   55 kgs  gt 55 kgs    3  Heavy Equipment    4 This equipment is very heavy and should be moved using a mechanical lift to avoid  injuries     Mellanox Technologies 19        
97. l waste electrical and electronic  equipment  EEE  should be collected separately and not disposed of with regular  household waste     Dispose of this product and all of its parts in a responsible and environmentally  friendly way     Go to the Mellanox website for detailed instructions for disassembly according to the  WEEE Directive     Mellanox Technologies 81    AA  RECI    Appendix A       InfiniBand FDR Switch Platform Hardware User Manual      Specification Data    Table 17   Switch Specification SX6512  4N R       Physical       15 75    x 19    x 27    inches                   Size 400mm x 482 6mm x 685 8mm  The shelf adds 44 5mm to the height  Mounting 19    rack mount    of spines 6    of leafs 12  48kg  105 lbs  empty configuration  Weight 83 94kg  185 Ibs  shipped configuration  147kg  324 lbs  full configuration  CoGh  311 80mm  from bottom of chassis   Center of CoGw  222 00mm  from left side surface   Gravity  CoGd  328 14mm  from port end surface      Measured from the bottom left corner as one faces the switch ports       Max  Air Flow  Through Leafs    9 186M  min  324 6               Max  Air Flow  Through  Spines    2 533M   min  89 5 CFM        Total Max  Air  Flow    11 719M3 min  414 0               SerDes Speeds    10  20  40 Gb s or 56 Gb s per port                               Connector QSFP  Types  Sound Level   76 db A     of Ports 216  Power and Environmental  Input Voltage   100   240 VAC 50 60Hz  Typical Passive  1832W  Active  2325W  include
98. latform Hardware User Manual      Revision History    Table 1   Revision History of this User s Manual                   Revision Date Details   2 5 Nov 30  2015  Updated 1600W PSU power from 1600W to 1670W   24 Nov 26  2015 Updated Appendix F     Replacement Parts Ordering Numbers     on page 92 spine  and leaf module OPNs   2 3 Nov 18  5 Updated Table 12   Management LED Display for Normal Operation   on  page 68   2 2 June 30 2015  Updated     e Section 2 3     Chassis Package Contents          page 24  e Section G 13     Japan VCCI Class A Statement     on page 130       2 1 Feb 24  2015 Updated      Table 12     Management LED Display for Normal Operation     on page 68 with  master LED status indicators     Appendix A     Specification Data     on page 82 with FDR10 power numbers  and max heat output     Appendix D     Calculating the Power of a Chassis     on page 87 with FDR10  power numbers       2 0 Nov 17 2014     e Section 1 4 2     1670W Power Supply Units     on page 17  e Section 2 7 1 3     Container Mishandling     on page 28     Appendix A     Specification Data     on page 82       1 9 Oct 27  2014 Updated     Max  Air Flow numbers in Appendix A     Specification Data     on page 82    N 1 configuration in Section 1 4 2     1670W Power Supply Units     on page 17       1 8 July 18  2014  Updated    e Section 2 7 4     Ground Connections     on page 41     Appendix A     Specification Data     on page 82     Appendix D     Calculating the Power of a Chassis 
99. list  Check the  parts for visible damage that may have occurred during shipping     If anything is damaged or missing  contact your customer representative immediately          The rack mounting holes conform to the EIA 310 standard for 19 inch racks  Guaran   tee proper ventilation  by leaving 8cm  3     of space to the front and rear ofthe switch   This will ensure proper air flow through the chassis  This is crucial for maintaining  good airflow at ambient temperature  In particular  route cables such that they do not  impede the air into or out of the chassis     4    2 4 Leaf Package Contents    The leafs are ordered by the customer and are shipped 4 to a box  The customer will  receive as many boxes as needed to fill the order     2 5 Spine Package Contents    The spines are shipped 3 to a box  The customer will receive as many boxes as needed to  fill the chassis with a full complement of spines          Insert the bottom spine board first        2 6 Management Package Contents  The package includes     e all of the management modules ordered by the customer    e   RJ45 to DB9 harness for each management module received    2 7 Physical Installation    Warning  This equipment is very heavy  Safety is the first concern  Make sure that    adequate manpower and proper equipment is used for transporting and moving the     chassis     The fully loaded chassis weighs    120 kg  265 LBS  full configuration   48 KG  105 LBS  empty configuration  83 94kg  185 LBS  shipped confi
100. ma pari a 1 5 m  sei piedi  ma non pi   lunga di 4 5 m    Per una connessione europea  selezionare un cavo di alimentazione armonizzato a  livello internazionale e contrassegnato da     lt HAR gt      a 3 conduttori  minimo 1 0 mm2  fili  con guaina isolante in PVC  Il cavo deve disporre di una spina stampata di potenza  nominale pari a 250 V  10 A        17  Corrente di dispersione elevata    Avvertenza  corrente di dispersione elevata  il collegamento a terra    essenziale prima  di collegare l   alimentazione     Mellanox Technologies 125       Rev 1 3    18  Interconnessione delle unit      A I cavi per il collegamento all   unit   RS232 e alle interfacce Ethernet devono  4   disporre della certificazione UL ed essere del tipo DP 1 o DP 2   Nota  in caso  4 y di installazione su un circuito la cui potenza non    limitata     Protezione contro le sovracorrenti  la cablatura dell   edificio deve integrare un  dispositivo di protezione contro le sovracorrenti di potenza nominale pari a 20     19  Non utilizzare lo switch come scaffale o piano di lavorol    Attenzione  un   apparecchiatura scorrevole o montata su binari non va utilizzata come  scaffale o piano di lavoro  I binari non sono progettati per far scorrere e allontanare  l   unit   dal rack  Essi sono destinati all   installazione permanente solo nel luogo di  lavoro e non vengono utilizzati per assistenza e manutenzione    20  Direttiva RAEE  Secondo la direttiva RAEE 2002 96 EC  tutti i rifiuti da apparecchiature 
101. must be started with a full complement of possi   ble PSUs  thereafter it can run on one less than the total number of PSUs  This final PSU  is redundant and allows for hot swapping a PSU should one fail  Connecting the PSUs to  different AC lines provides AC failover protection     The system should continue to run and allow a hot swap of a defective PSU  Should  there not be enough power to keep all of the leafs running  MLNX OS   may power  down some leafs  If this happens it will be necessary to reboot the chassis once the defec   tive PSU has been replaced     With 1670W optional PSU supplies the chassis can run on as little as 1 2 of the full com   plement of PSUs  N N allows the chassis to run on 2 PSUs supplied from one power  grid while 2 are connected to a second power grid     1  Check all FRUs for proper insertion and seating before connecting the AC power  cords       Boards     Power supplies   e Leaf fan modules    Spine fan modules    2  Insert all leafs that you plan to use  in the chassis  Start at the bottom of the chassis  and work your way up     Insert the first two spines in the top two slots    Insert the rest of the spines from the bottom of the chassis up to slot  3   Insert thermal blanks in unused leaf slots to maintain balanced air flow   Tighten all leaf and spine mounting screws     Connect the power cords to the PSUs     Ol cU e M    Connect the power cords to grounded electrical outlets     2  4 N With N 1 PSU redundancy do not power up the ch
102. ngen des Kabelherstellers        10  Rack Montage und Wartung    sichtsma  nahmen zu ergreifen  um die Stabilit  t des Systems zu gew  hrleisten  Im    Wenn dieses Produkt in einem Rack montiert oder gewartet wird  sind besondere Vor   A Allgemeinen sollten Sie das Gestell von unten nach oben mit Ger  ten f  llen     11  Ger  teinstallation    A V Diese Ger  t sollte nur von geschultem und gualifiziertem Personal installiert  aus       getauscht oder gewartet werden        12  Ger  teentsorgung      N  N  A    Die Entsorgung dieses Ger  ts sollte unter Beachtung aller nationalen Gesetze Bestim   mungen erfolgen          4       13  Regionale und nationale elektrische Bestimmungen    Dieses Ger  t sollte unter Beachtung der regionalen und nationalen elektrischen Bes   timmungen installiert werden        14  Installationscodes    installiert weden  In Nodamerika muss das Ger  t gem     den geltenden Anforderungen    EN  4 N Dieses Ger  t muss entsprechend der aktuellsten Version des National Electrical Code          des US National Electrical Code und des Canadian Electrical Code installiert werden          SE    108 Mellanox Technologies      Rev 2 5      15  UL  und CSA zertifiziertes Netzkabel    F  r Nordamerika Stromanschluss  w  hlen Sie ein Netzkabel  das UL und CSA Certi   fied   3   Leiter   18 AWG   mit einem angespritztem Stecker bewertet bei 125 V   15   mit  einer Mindestl  nge von 1 5 m  Six Feet  aber nicht mehr als 4 5 m        F  r die europ  ischen Zusammenhan
103. niBand                 on                                   gt                                                                                                                                               PINI                                                                                 12                                                                                                                                                                                               NINI                                                                             gt                            13                                                                                                                                                                                    14                          DINI                                                                                                                                                                       15     gt                                                                                                                                              16                                                    NASI                                  919                       Y N UL                            CSA    3                16  AWG                                      13A     125                               1 5         6                                          4 5                                                235  
104. niBand FDR Switch Platform Hardware User Manual      11  During Lightning   Electrical Hazard    During periods of lightning activity  do not work on the eguipment or connect or dis   connect cables     12  Copper InfiniBand Cable Connecting Disconnecting    Copper InfiniBand cables are heavy and not flexible  as such they should be carefully  attached to or detached from the connectors  Refer to the cable manufacturer for spe   cial warnings instructions        13  Rack Mounting and Servicing    When this product is mounted or serviced in a rack  special precautions must be taken  LA to ensure that the system remains stable  In general you should fill the rack with equip   ment starting from the bottom to the top     14  Equipment Installation    This equipment should be installed  replaced  and or serviced only by trained and qual   ified personnel        15  Equipment Disposal    AN      A Disposal of this equipment should be in accordance to all national laws and regula       tions        16  Local and National Electrical Codes      N This equipment should be installed in compliance with local and national electrical    codes             17  Installation Codes    A This device must be installed according to the latest version of the country  A    national electrical codes  For North America  equipment must be installed in  A   accordance to the applicable requirements in the US National Electrical Code  7 and the Canadian Electrical Code   Mellanox Technologies 21        
105. nmal  d  r  Genelde  ekipmanlar   iskeleye a  a    dan yukar    do  ru doldurman  z gerekir     12  Ekipman Montaj      Ekipman  n yaln  zca e  itimli ve nitelikli personel taraf  ndan monte edilmesi   de  i  tirilmesi ve veya bak  m  n  n yap  lmas   gerekir           128 Mellanox Technologies      Rev 2 5      14  Yerel ve Ulusal Elektrik Kodlar             Bu cihaz  n    lke ulusal elektrik kodlar  n  n son s  r  m  ne g  re monte edilmesi  hh V gerekir  Kuzey Amerika i  in  ekipman  n ABD Ulusal Elektrik Kodu ve    Kanada Elektrik Kodu nun uygulama kosullarina gore monte edilmesi gerekir        16  UL Kay  tl   ve CSA Onayl   G     Kayna     Kablosu    A Kuzey Amerika da g     ba  lant  s   i  in  UL Kay  tl   ve CSA Onayl   bir g     kayna      4   kablosu se  in  3   iletken   16 AWG   125 V de  erinde  kal  planm     bir fi  le biten        13 A   en az 1 5 m  alt   fit  uzunlu  unda fakat 4 5 m den uzun olmayan bir kablo     Avrupa da g     ba  lant  s   i  in  uluslararas   uyumlu ve     lt HAR gt     i  aretli    3   iletken  en az 1 0 mm  tel  300 V de  erinde ve PVC yal  t  ml   bir g      kayna     kablosu se  in  Kablonun 250 V  10 A de  erinde bir kal  planm     fi  i  olmas   gerekmektedir     17  Y  ksek Ka  ak Ak  m      Uyary  Y  ksek ka  ak ak  m varsa  g     kayna    na ba  lanmadan   nce mutlaka toprak   lama ba  lant  s   yap  lmal  d  r     18    nitelerin Ara Ba  lant  s      RS232   nitesini ve Ethernet Arabirimlerini ba  layacak olan kablolar  n UL 
106. nt power or a blank in its place  In case of a blank  A fastened     8  Multiple Power Inlets  Risk of electric shock and energy hazard   The PSUs are all independent   Disconnect all power supplies to ensure a powered down state inside of the switch  platform     9  During Lightning   Electrical Hazard      During periods of lightning activity  do not work on the equipment or connect or dis   connect cables     10  Copper InfiniBand Cable Connecting Disconnecting    Copper InfiniBand cables are heavy and not flexible  as such they should be carefully  attached to or detached from the connectors  Refer to the cable manufacturer for spe   cial warnings instructions        11  Rack Mounting and Servicing    to ensure that the system remains stable  In general you should fill the rack with eguip       When this product is mounted or serviced in a rack  special precautions must be taken  A ment starting from the bottom to the top     12  Equipment Installation    This equipment should be installed  replaced  and or serviced only by trained and qual   ified personnel        94 Mellanox Technologies      Rev 2 5      13  Eguipment Disposal      N       N      Disposal of this equipment should be in accordance to all national laws and regula   4   tions        14  Local and National Electrical Codes    y  V This eguipment should be installed in compliance with local and national electrical  4   codes        15  UL Listed and CSA Certified Power Supply Cord    A For North American po
107. of a 4X port runs a bit rate of 14 0625Gb s with a 64b 66b encoding   resulting in an effective bandwidth of 54 54Gb s  The FDR physical layer is an IBTA  specified physical layer using different block types  deskew mechanism and framing  rules     The SX6512 switch also supports FDR10  a non standard InfiniBand data rate  where  each lane of a 4X port runs a bit rate of 10 3125Gb s with a 64b 66b encoding  resulting  in an effective bandwidth of 40Gb s     FDR10 supports 20  more bandwidth over regular QDR using the same QSFP cables   connectors     Both FDR and FDR10 support Forward Error Correction  FEC   as described in IEEE  Std 802 3ap 2007  Amendment to IEEE Std 802 3 2005  chapter 74       FDR              10 are only guaranteed to work with approved                cables           FDR 10 is only guaranteed to work with approved Mellanox ConnectX 3 adapters   di    1 4 Power Supply Redundancy  The SX6512 platform comes standard with four power supplies and has two order  options   e SX6512 4R   N 1 redundancy      SX6512 NR         redundancy       1  Features for a future release     Mellanox Technologies 16       0 Mi an      InfiniBand FDR Switch Platform Hardware User Manual      1 4 1 1000W Power Supply Units    The 1000W power supply units  PSUs  deliver 1000W at 48V  The AC source to each  PSU must be able to provide 1176 5W in order to output 1000W in DC     With 1000W PSUs the only redundancy option is N 1  In this configuration IPSU can  be extracted without
108. onal  Red     PS fault detected  User should check individual power supplies  for fault indications   SPINE FANS   Off   No power to fan Green  STATUS Green     Nominal operational  Red     One or more of the spine fans is bad  User should check individ   ual spine fan LEDs for fault indications   LEAF FANS   Off  No power to fan Green  STATUS Green     Nominal operational  Red     One or more of the leaf fans is bad  User should check individual  leaf fan LEDs for fault indications   MASTER Off   Green if master    no power Off if slave    this management module is not the master  Green     Management module is operating as a master  Mellanox Technologies 68    e Xi IE       InfiniBand FDR Switch Platform Hardware User Manual      Figure 56  Management Module LEDs    LFANS Master       3 1 5 1 Management Module PSU LED Indicator    The management module PSU indicator should be green   Table 13   Management Module PSU LED Configurations             LED Condition Description  Green OK     All PSUs are working at correct input and output voltages   Red Error     One or more of the PSUs for the chassis is bad  Check each  PSU for a red LED                 3 1 5 2 Management Module S  FANS LED Indicator    The management module S  FANS indicator should be green   Table 14   Management Module S Fan LED Configurations             LED Condition Description  Green OK     All Spine fans are working at configured speed   Red Error     One or more of the spine fans within a spine fan mo
109. ostor na njegovu mjestu   N lopac uklonjen ili ako nije dobro pri  vr    en     8  Vi  estruki ulazi za napajanje    Rizik od strujnog udara i opasnost od elektri  ne energije   PSU jedinice su neovisne     Odspojite sva napajanja kako biste osigurali stanje bez napajanja unutar platforme  preklopnika     9  Tijekom udara munje   Opasnost od elektri  ne energije    A Tijekom djelovanja munja  nemojte raditi na opremi ili spajati ili odspajati kabele     10  Spajanje Odspajanje bakrenog kabela InfiniBand    Bakreni kabeli InfiniBand su teski 1 nesavitljivi i kao takvi se moraju pazljivo prikl   juciti na ili isklju  iti iz konektora  Obratite se proizvo  a  u kabela za posebna upo   zorenja upute        11  Monta  a ormari  a i servisiranje    opreza kako bi se osiguralo da sustav ostane stabilan  Op  enito  trebali biste ispunja       Kad se proizvod montira ili se servisira u ormari  u  moraju se poduzeti posebne mjere  vati ormari   s opremom po  ev  i od dna prema vrhu     12  Instaliranje opreme    Ovu bi opremu trebalo instalirati  zamjenjivati i ili servisirati samo obu  eno i kvalifici   rano osoblje           Mellanox Technologies 121      Rev 1 3      14  Lokalni i nacionalni elektri  ni kodovi    Ova oprema trebala bi se instalirati u skladu s lokalnim i nacionalnim elektri  nim  kodovima        15  Instalacijski kodovi    A Ovaj se ure  aj mora instalirati sukladno najnovijoj verziji nacionalnih elek   PA  N tri  nih kodova dr  ave  U Sjevernoj Americi oprema se mo
110. ower enable  lt module gt    To shut down a spine run the following command   no power enable  lt module gt     To shut down a management module run the following command     no power enable  lt module gt     Mellanox Technologies    60         InfiniBand FDR Switch Platform Hardware User Manual    3   nterfaces    3 1 LED Status Indicators    The LEDs are placed on the chassis for the convenience of the TT manager  All chassis  conditions and management options are available and controllable through the manage   ment software  either CLI or WebUI     Y It is recommended that all of the chassis sub systems be maintained and managed  through the management software        3 1 1 Power Supply Unit LEDs  Each Power Supply Unit has the following indicator LEDs     Figure 50  Power Supply Unit Status Indications                                            DC         AC  OK FAIL OK    AC     When lit this LED indicates input voltage between 100 and 240 Volts   DC FAIL     When lit this LED indicates a fault in the power supply     DC OK     When lit this LED indicates that the output from the power supply is  48  VDC         A The PSUs are on the spine side of the chassis behind two cover panels  The plugs for  these PSUs are on the leaf side of the chassis         Mellanox Technologies 61      InfiniBand FDR Switch Platform Hardware User Manual      PSU Cover On and Off  PSU Covers On    Figure 51    FRONT SIDE ORCA SX6512          PSU Covers Off       62    Mellanox Technologies   
111. ower level 2 according to the          Public Specification   Management Module Interfaces    The switch system requires at least one management module  The management module  has five interfaces to connect to the SX6512  They are       112C port    1 CONSOLE port     this is an RS232 connector for connecting to a host  machine        MGT   this is an Ethernet connector  e 1 USB port  e 1 RST  reset button    Mellanox Technologies 70         InfiniBand FDR Switch Platform Hardware User Manual    Figure 59  Management Module Interfaces                   3 4 1 12C    This interface is for Debug and Troubleshooting only  This interface is for FAEs  als only     3 4 2 CONSOLE    The CONSOLE port is used during the installation process to configure the chassis for  remote management  Connect this port to a local host using the harness supplied with the  chassis  See the Installation Guide for the initial configuration procedure     3 4 3 MGT  Management    The MGT port is an Ethernet port for remote management  Any remote terminal con   nected to the Ethernet port can then be used to manage the fabric and chassis     Each Ethernet connector gets connected to Ethernet switches  These switches must be  configured to 100M 1G auto negotiation     4    Initial configuration must be done on all of the management modules  The first man   agement module you configure will be the master     4    3 44 USB    The USB port can be used to upload new SW using any storage device that has a USB  
112. pendantes          Pour s assurer que le commutateur est bien hors tension  d  branchez toutes les alimen   tations     9  En cas d orage  danger d   lectrocution      Pendant un orage  ne pas travailler sur l   quipement ni brancher ou d  brancher des    c  bles     10  Connexion et d  connexion du c  ble InfiniBand en cuivre    Les c  bles InfiniBand en cuivre sont lourds et peu flexibles  Par cons  quent  il faut  proc  der avec soin pour les brancher ou les d  brancher des connecteurs  Consulter le  fabricant du c  ble pour obtenir des instructions ou des avertissements sp  cifiques        104 Mellanox Technologies      Rev 2 5      11  Montage en rack et maintenance    ment attention pour s assurer que l ensemble reste stable  En r  gle g  n  rale  le rack doit      Lors du montage ou de la maintenance de ce produit dans un rack  il faut faire sp  ciale   N  amp tre rempli en commengant par le bas     12  Installation de l   quipement         Cet   quipement ne doit   tre install    remplac   et maintenu que par un personnel form        et qualifie                  mise au rebut de cet   quipement doit se faire conform  ment a toutes les lois et      r  glementations nationales        14  Codes   lectriques locaux et nationaux       A IN Cet   quipement doit   tre install   conform  ment aux codes   lectriques locaux et nation   aux                 15  Codes d installation    Cet appareil doit   tre install   conform  ment    la version la plus r  cente des codes   lec  
113. prapus peste niciun alt echipament  In cazul in care cadrul       cade  poate cauza leziuni corporale   i deterior  ri ale echipamentului        7  Conexiunea la o surs   de alimentare electric   suplimentar     pericol electric        Acest produs include o surs   de alimentare suplimentar   sau un spatiu gol   n locul     prox p pat  u g  A   acesteia    n cazul   n care spatiul pentru sursa de alimentare este gol  nu operati produ     y sul c  nd capacul orb este indep  rtat sau nu este fixat in mod sigur     Mellanox Technologies 117      Rev 1 3      8  Multiple mufe electrice  Risc de   oc electric   i pericol electric   y Toate aparatele cu alimentare de la re  ea sunt independente   Deconectati toate sursele de alimentare cu energie pentru a asigura decuplarea   n inter   iorul platformei de comutare     9    n timpul desc  rc  rilor electrice   pericol electric           n timpul perioadelor cu desc  rc  ri electrice luminoase  nu lucrati cu echipamentul sau      nu conecta  i sau deconectati cablurile        10  Conectarea deconectarea cablului din cupru InfiniBand      N   a  Cablurile InfiniBand din cupru sunt grele   i inflexibile  de aceea trebuie s   fie ata  ate    4    sau deta  ate de conectori cu grij    Consulta  i produc  torul de cabluri pentru avertis   y mente instructiuni speciale             11  Montarea        depanarea intr un rack    y  N C  nd acest produs este montat sau depanat   ntr un rack  trebuie s   fie luate m  suri de  A   precautie spec
114. ra instalirati suk        ladno va  e  im zahtjevima navedenim u US National Electrical Code i       Canadian Electrical Code     16  UL CSA kabel napajanja    IN Za sjevernoameri  ku mre  u odaberite kabel napajanja koji je na UL listi 1 sa  MA CSA certifikatom  3   Zilni   16 AWG   16 AWG  koji zavr  ava lijevanim uti       ka  em nazivnog napona od 125 V   13 A   minimalne duljine od 1 5 m  six  feet     est stopa   ali ne dulji od 4 5 m    Za europsku mre  u odaberite kabel napajanja koji je me  unarodno uskla  en i  ozna  en     lt HAR gt      3     ilni  s najmanje 1 0 mm    ice  nazivnog napona od  300 V  s PVC izolacijom  Kabel mora imati lijevani utika   nazivnog napona od  250 V  nazivne struje od 10 A     17  Veliko curenje struje    4 Upozorenje  Veliko curenje struje  Prije spajanja napajanja nuZno je spojiti uzeml   jenje     18  Interkonekcija ure  aja    Kabeli za spajanje na jedinicu RS232 1 Ethernet su  elja moraju biti s UL cer   tifikatom vrste DP 1 ili DP 2   Napomena   kad se nalazi u krugu bez LPS  vodi  a    Za  tita od strujnog preoptere  enja  Uvijek dostupni odobreni za  titni ure  aji    od strujnog preoptere  enja nazivne struje od 20 A moraju se ugraditi u  o  i  enje zgrade        19  Nemojte koristiti preklopnik kao policu ili radnu povr  inu    Pozor  Oprema montirana na kliza  e vodilice ne bi se trebala koristiti kao polica ili  radna povr  ina  Vodilice nisu namijenjene za povla  enje ure  aja iz ormari  a  Slu  e  samo za trajnu instalacij
115. renja za instaliranje  Croatian                 120  G 11 Avvertenze di sicurezza per l installazione  italiano               123    Mellanox Technologies 4        InfiniBand FDR Switch Platform Hardware User Manual      2 MontajG  venlikUyar  lar   T  rk  e                            127  3 Japan VCCI Class    Statement                             130       _            G   G     Mellanox Technologies 5        InfiniBand FDR Switch Platform Hardware User Manual    List of Tables    Table 1  RevisionHistoryofthisUser sManual                                  9  Table 2  Reference Documents and Websites                                  10  Table 3  OPNs for Power Supply Units                                        18  Table 4  leafStatuslED                            een en 63  Table 5  Bad Port LED                                                                  63  Table 6  Connector Physical and Logical Link Indications                          64  Table 7  SpineStatuslRD                           tee 65  Table 8  Spine Fan Status LED                                              65  Table 9  Spine to Leaf IB Link Status                                         66  Table 10  Bad Port LED                                                                  66  Table 11  Spine Side LED Display for Normal Operation                           67  Table 12  Management LED Display for Normal Operation                         68  Table 13  Management Module PSU LED Configurations         
116. s QSFP at 1 5W   Total Power Optical  2391 W  includes          at 1 7W   Consumption  FDR 10 Maximum Passive  2129W  Active  2688W  includes QSFP at 1 7W   Optical  2787W  includes QSFP at 2 0W   FDR 10 Max   9 509 BTUs hr  Heat Output          ellanox Technologies    82           InfiniBand FDR Switch Platform Hardware User Manual      M    Table 17   Switch Specification SX6512  4N R       Physical       Total Power    Typical Passive  2284W  Active  2777W  includes QSFP at 1 5W   Optical  2843W  includes QSFP at 1 7W                                               Consumption  FDR 14 Maximum Passive  2388W  Active  2946W  includes QSFP at 1 7W   Optical  3046W  includes QSFP at 2 0W   Max Heat 10 393 BTUs hr  Output  eur Operating  0   to 45   Celsius     Non operating   40   to 70   Celsius  Humidity Operating  10    85  non condensing  Protocol Support  Speed Protocol   InfiniBand  Auto negotiation of 56Gb s 40Gb s  20Gb s  10Gb s  MLNX OS and baseboard  performance  and device management agents for full Infini   Management    Band in band management   Data Rate 56Gb s per port  QoS 8 InfiniBand virtual lanes for all ports  Regulatory Compliance  US Canada  cTUVus certificate  International  CB report and  certificate  Saft Russia  GOST R certificate  x Argentina  S mark certificate  DoC  BSMI certificate  for the power supply only   CE EMC  amp  safety report and certificate  USA  FCC part 15 class A  ms Canada  ICES 003 class A   missions  Australia   New Zealand   AS N
117. shall check whether or not the socket   outlet from which the  equipment is to be powered provides a connection to the building protective earth  If  not  the SERVICE PERSON shall arrange for the installation of a PROTECTIVE  EARTHING CONDUCTOR from the separate protective earthing terminal to the pro   tective earth wire in the building  The equipment shall be installed in area where equi   potential bonding exists   such as a telecommunication centre or a dedicated computer  room      22  Installation codes    A    This device must be installed according to the latest version of the country national  electrical codes  For North America  equipment must be installed in accordance to the  applicable requirements in the US National Electrical Code and the Canadian Electri   cal Code     23  Interconnection Of Units       Cables for connecting to the unit RS232 and Ethernet Interfaces must be UL  certified type DP 1 or DP 2   Note  when residing in non LPS circuit     Overcurrent Protection  A readily accessible Listed branch circuit overcurrent  protective device rated 20 A must be incorporated in the building wiring     22    Mellanox Technologies         InfiniBand FDR Switch Platform Hardware User Manual    M    24  Hazardous Radiation Exposure    Caution     Use of controls or adjustment or performance of procedures other  than those specified herein may result in hazardous radiation exposure     CLASS 1 LASER PRODUCT and reference to the most recent laser standards  TEC 60
118. switch     5 1 InfiniBand Subnet Manager    The InfiniBand Subnet Manager  SM  is a centralized entity running in the switch  It dis   covers and configures all the InfiniBand fabric devices to enable traffic flow between  those devices  The SM applies network traffic related configurations such as QoS  rout   ing  partitioning to the fabric devices     You can view and configure the Subnet Parameters  SM  via the CLI WebUI     Each InfiniBand subnet needs one subnet manager to discover  activate and manage the  subnet  An InfiniBand amp  network requires a Subnet Manager to be running in either the  Infiniband switch itself  switch based  or on one of the nodes which is connected to the  Infiniband fabric  host based      5 2 Fabric Inspector  Diagnostics   Fabric Inspector is a plug  amp  play software for fee within MLNX OS displaying and fil   tering all identified systems and nodes within the fabric     Fabric Inspector includes a complete set of tools for fabric wide diagnostics to check  node node and node switch connectivity and to verify routes within the fabric     Advanced filtering allows creating filtering rules on a system wide basis  between nodes  or port connections based on traffic patterns and user assigned system names  GUIDs      5 3 Accessing the CPU via the Ethernet Connector    Once the initial configuration is completed the management tools can be accessed    through      SSH     Telnet    WEB     SNMP    XML    5 4 Upgrading Software    The new softw
119. t Module    CONSOLE ci            PSU SFANS LFANS Master m              os  oo               Ejectors    2 10 5 1 Inserting a Management Module    When hot swapping any of the units  it is necessary to wait 1 minute after removing  the defective part before inserting the new part  This is necessary so that the manage   ment module will start a new cycle checking through the leafs and spines for the FW  versions     To insert a management board   1  Check for foreign objects in or mechanical damage to the chassis management slots   2  Check management mechanics for any noticeable damage     3  Check back signal connectors    integrity  Look for any broken signal dividers or any  deviations from the pass criterion shown in Figure 48     Figure 48  Intact vs Defected Signal Connectors       Fail       Mellanox Technologies 58      InfiniBand FDR Switch Platform Hardware User Manual      4  Check power connector   s integrity  Look for any damage on the power connector  casing or blades damage  or any deviations from the pass criterion shown in  Figure 49     Figure 49  Intact vs Defected Power Pin Holders       5  Start with the ejector handles fully open  that is  at 45 degrees to the front panel of the  management     6  Holding the management by its sides  carefully set the management board into the  chassis     7  Using only the management ejector handles  slowly slide the board into the chassis  until the hooks reach the vertical bar     Do not apply excessive force to slid
120. t coulissant ou monte sur rail ne doit pas servir d   tag  re ni de   plan de travail  Les rails ne sont pas destin  s a faire coulisser l unit   hors du rack  Ils   sont destin  s a une installation permanente a l emplacement final  pas pour l entretien   ni la maintenance     20  Directive DEEE  Selon la Directive 2002 96 CE  DEEE   tous les d  chets d   quipements   lectriques et    lectroniques  EEE  doivent   tre collect  s s  par  ment et ne pas   tre mis au rebut avec  les d  chets m  nagers habituels   Ce produit et toutes ses pieces doivent   tre mis au rebut d une mani  re responsable   respectant l environnement   ran    21  Restrictions concernant l alimentation pour la Norv  ge    Cet appareil est prevu pour   tre reli   a un systeme d alimentation TN et un systeme  d alimentation informatique de Norv  ge uniquement        G6 Installation Sicherheitshinweise German     1  Installationsanleitungen      N Lesen Sie alle Installationsanleitungen  bevor Sie das Ger  t an die Stromversorgung    N anschlie  en     106 Mellanox Technologies    Rev 2 5       2  Verletzungsgefahr wegen des Gewichts    da    Um das Produkt sicher anzuheben  gen  gend Personen einsetzen     Mal     lt 40 Ibs 40   70 Ibs 70   121 Ibs  gt 121 lbs   lt 18 kgs 18   32 kgs 32   55 kgs  gt 55 kgs       3  Schweres Ger  t    Dieses Ger  t ist schwer und muss mit einem mechanischen Hebeger  t verschoben  werden  um Verletzungen zu vermeiden        4  Stromschlagrisiko    Stromschlagrisiko    Bei ab
121. t software automatically discovers and configures the fabric and begins  utilizing the switch     The Mellanox Operating System  MLNX OS    software package provides a subnet  manager and network management tools as well as connectivity software for servers and  storage  and is available on the Mellanox web site    Basic installation is covered in Chapter 2     Installation    on page 19     Hot swapping components and hardware maintenance is covered in Chapter 2 10     Hot  Swap Insertion and Extraction    on page 44        1 1 Product Information    1 1 1 Serial Number and Product Version Information    The serial number  GUID identifier and product version information are found on the  label attached to the pull out tab below the Mellanox logo on the spine side of the chas   sis     Figure 1  Product Label    2 S N  MT0806X01504  AIT                 MSX6506 3R          curo  0002c9020027051c       EA en          MAC  0002C9020040    UN di    Made in Israel         Mellanox Technologies 13        InfiniBand FDR Switch Platform Hardware User Manual      The GUID is the System Image GUID according to the IB spec  It is burned on the board  which is in the chassis  All the boards and the management software look for this GUID  in addition to their own Node GUID     Figure 2  Product Label Tab Location                            ETS       ane de de wi  AAA A d t    a                MZ    L              Here is the tab with  the product label         TENTE    maka dh     KRA 5  
122. te   4  Remove and put aside the box     5  Visually inspect the chassis  make sure that       there is no visible damage    4PSUs are installed for the chassis      all4 fans are installed    6  Remove all protective plastic film from all sides and top of the chassis     7  If you are not using a mechanical lift to install the chassis  reduce the weight of the    chassis by removing all of the power supply units  and fan units  and put aside for  reinstallation after the chassis is installed in the rack      P The leafs  spines  and management modules are shipped separately             2 7 1 5 Installing the Shelf  1  Place the ESD mat on the floor where you will be working and put on the ESD strap     Make sure the ESD strap is touching your skin and that the other end is connected to  a verified ground       Make sure you have the spine side close to the doors to ensure maximum cable bend     ing room    Mellanox Technologies 30        InfiniBand FDR Switch Platform Hardware User Manual      Figure 10  Placement of Chassis in Rack    Doors    RACK         Cable with  recommended  bending radius    Chassis    E Spinelside          Insufficient room for recommended  bending radius    Doors    You will most likely need extra room for cable bending on the connector side of the chas   sis and should plan to keep the spine side as close to the rack door as possible  thus hav   ing more room for the cables  See Figure 1 on page 36     3  Clip 4 caged nuts into the holes in the ra
123. tform Hardware User Manual      Figure 14  Chassis on Shelf with Filler Panel    Shelf    Filler panel       Mellanox Technologies 33      InfiniBand FDR Switch Platform Hardware User Manual       2 7 2 Installing the Cable Holder    Y Now is the time to install the cable holder     Figure 15  Cable Holders  tl side cable holder      gt  12 X M6 caged nut       1 12 X M6 bolt for caged nut    pu    Left side cable holder    b       1  Place the cable holder next to the rack  on the connector side of the chassis  and iden   tify the holes where the caged nuts are to be placed     EU       Cable support shelf  For each model of chassis there  is the one support shelf for every  two leafs        The cable holders should go to the outside of the vertical supports        Mellanox Technologies    34         InfiniBand FDR Switch Platform Hardware User Manual    2  Set the bottom of the cable holder at the level of the shelf     A If the cable holder is not set properly the upper bracket will not line up with the cable       holder     Figure 16  Cable Holder Placement       Notch for upper  bracket washer          Set this even with  the top of the shelf    Screw the cable holder onto the rack using the screws provided   Repeat steps 1 3 for the second cable holder   Install the shelves  The cable support shelves just sit on the cable holders     ds 209            Use the holes in the shelves to tie down the cables individually or in bundles     A Use Velcro ties to tie down the ca
124. tus LED for the spine fan modules     36status LEDs showing the existence of leaf to spine connections    One Bad Port Led showing symbol errors in the data stream     OneUID LED that can be lit to identify an individual spine    The 36 LEDs on each spine are divided by the number of leafs and the result  N  is the  number of connections from each leaf that are connected to the spine  6 spines must be  installed and working to ensure that full BW exists between nodes  The maximum num   ber of connections from each leaf is 3  If the  number of leafs  x  the maximum number    ellanox Technologies 64       ei        InfiniBand FDR Switch Platform Hardware User Manual      of connections per leaf  is less than 36 then some of the leaf to spine connection LEDs  may be OFF     The status LEDs for the spine and their descriptions are shown in Table 7  The LEDs  indicate as follows     Figure 53  Spine Status LEDs  Spine Status LED    Fan Status LED  Bad Port LED    UID LED          uy SO 3e LS    HERE  6 8 10 12 14 16 18       Spine leaf IB connection status    3 1 3 1 Status LED  N    Table 7 shows the spine status according to the LED condition     Table 7   Spine Status LED                         LED Condition LED Description  Off No power to the spine  Solid Green Spine is up and running  Flashing Green Spine is powering up  Solid Orange Non fatal error     this spine needs troubleshooting  but does not  require chassis shutdown  Solid Red Fatal error       3 1 3 2 Fan LED     
125. u na kona  nom polo  aju  a ne za servisiranje i odr  avanje     122 Mellanox Technologies          20  WEEE direktiva    Sukladno WEEE direktivi 2002 96 EZ  sav elektri  ni i elektroni  ki otpad  EEE  trebao  bi se prikupljati zasebno i ne bi se trebao odlagati kao obi  an ku  anski otpad     Odlaganje ovog proizvoda i svih njegovih dijelova vr  ite na odgovoran i ekolo  ki  na  in     21  Elektri  na ograni  enja dr  ave Norve  ke    Ovaj je ure  aj namijenjen samo za spajanje na elektri  ni sustav s TN uzemljenjem i na  elektri  ni sustav s IT uzemljenjem dr  ave Norve  ke        G 11 Avvertenze di sicurezza per l   installazione  italiano     1  Istruzioni di installazione    Leggere tutte le istruzioni di installazione prima di collegare l   apparecchiatura  all   alimentazione        2  Lesionia causa del peso    Ah     Usare un numero di persone sufficiente per sollevare in sicurezza questo prodotto          40 Ibs 40   70 Ibs 70   121 lbs  gt 121 Ibs   lt 18 kes 18   32 kc3 32   55 kgs  gt 55 kg       3  Apparecchiatura pesante    4 Questa apparecchiatura    molto pesante e va spostata mediante un sollevatore    meccanico  per evitare lesioni     Mellanox Technologies    1    2    3    Rev 2 5         Rev 1 3      4  Rischio di scosse elettriche      N Rischio di scosse elettriche        Con il modulo ventola rimosso  i pin di alimentazione sono accessibili all   interno della  4 N cavit   del modulo        NON inserire strumenti o parti del corpo nella cavit   del mo
126. wer connection  select a power supply cord that is UL Listed    N and CSA Certified  3   conductor   16 AWG   terminated with a molded plug rated at      125 V   13 A   with a minimum length of 1 5m  six feet  but no longer than 4 5m    LO  For European connection  select a power supply cord that is internationally    harmonized and marked     lt HAR gt      3   conductor  minimum 1 0 mm  wire  rated at    300 V  with a PVC insulated jacket  The cord must have a molded plug rated at 250 V   10 A     16  Installation codes    This device must be installed according to the latest version of the country national    electrical codes  For North America  equipment must be installed in accordance to the  applicable requirements in the US National Electrical Code and the Canadian Electri     cal Code     17  Interconnection Of Units    Cables for connecting to the unit RS232 and Ethernet Interfaces must be UL certified  type DP 1 or DP 2   Note  when residing in non LPS circuit     A readily accessible Listed branch circuit overcurrent protective device rated 20 A  must be incorporated in the building wiring        19  Do Not Use the Switch as a Shelf or Work Space    Caution  Slide rail mounted equipment is not to be used as a shelf or a work space  The  rails are not intended for sliding the unit away from the rack  It is for permanent instal   lation at final resting place only  not used for service and maintenance    Mellanox Technologies 95          Rev 1 3  20  WEEE Directive  
127. x Technologies      Rev 2 5      11  Montaggio su rack e manutenzione      Quando questo prodotto viene montato o sottoposto    manutenzione su un rack      Wm  necessario adottare delle precauzioni speciali per assicurarsi che il sistema resti stabile     In generale  il rack va riempito con apparecchiature  procedendo dal basso verso l alto     12  Installazione dell   apparecchiatura       A Ouesta apparecchiatura va installata  sostituita       sottoposta a manutenzione solo da  N pp p    N personale addestrato e qualificato      a  Lo smaltimento di questa apparecchiatura va effettuato in conformit   con tutte le leggi        e le normative nazionali        14  Codici elettrici locali e nazionali       PA N Questa apparecchiatura va installata in conformit   con le norme elettriche locali e    N    5    A nazionali        15  Codici di installazione    y  Questo dispositivo va installato in conformit   con l ultima versione dei codici elettrici  A V nazionali del Paese  Per il Nord America  l apparecchiatura va installata in conformit    con i reguisiti applicabili del    codice elettrico nazionale USA    e del    codice elettrico  q pp       canadese        16  Cavo di alimentazione UL e munito di certificazione CSA    Per una connessione di alimentazione nordamericana  selezionare un cavo di  alimentazione di tipo UL e munito di certificazione CSA  a 3 conduttori   16 AWG    terminato con una spina stampata con tensione nominale pari a 125 V   13 A   di  lunghezza mini
128. y recommended that the installation site building be equipped with a light   ning rod     It is highly recommended that the installation site be equipped with smoke detectors  and a fire alarm warning system     The system requires a KVA rated UPS system  It is recommended that a UPS system  be installed to protect the equipment in the event of unexpected power failure     Make sure that the outlets and circuits will not be overloaded  Spread out the load over  at least two or three circuits or use a 3 phase circuit      gt                     2 3 Chassis Package Contents  The package includes       1 box containing    installation kit parts    cable management system    power cords    1 shelf      1 chassis with the following modules installed       4 fans      4PSUs    If you are not using a mechanical lift to install the chassis  reduce the weight of the chas   sis by removing all of the power supply units  and fan units  and put aside for reinstalla   tion after the chassis is installed in the rack       1 installation guide   Inside the single box is 3 smaller boxes        installation kit box     1 box containing 4 power cords 250v 158 2 0M  C14 to C13  USA UL Standard        cable management kit    Mellanox Technologies 24        InfiniBand FDR Switch Platform Hardware User Manual        6 cable supporter boxes    Before you install your new SX6512 series chassis  unpack the system and check to  make sure that all the parts have been sent  check this against the parts 
129. ymbol error              This LED shows symbol errors  Possible causes for this are     bad cable   e bad connection     bad connector    This LED lights up when one or more ports is receiving a symbol error  The LED imme   diately goes off until the next symbol error is received     UID LED Switch Identifier    The UID LED is a debug feature that will become available to customers in the near  future  For details please contact Mellanox Technologies support     Spine Side Panel Display LED Indicators  The spine side panel display has LEDs that show the chassis condition     ellanox Technologies 66        InfiniBand FDR Switch Platform Hardware User Manual      Figure 54  Spine Side Panel Display Status Indications                               STATUS PSU SPINE LEAF MNG1 MNG2    FANS FANS MASTER MASTER       Table 11   Spine Side LED Display for Normal Operation                            Normal   LED Condition Description State  STATUS Off     No Power Green   Green     System is up and running   Yellow     System warning  Attention needed  such as overheating    Red     System not operational  Diagnostics fail  CPU hang    HW fail  Overheat critical    Blinking green     System booting   Restore factory defaults in progress  PSU STATUS  Off  No power Green   Green    Normal operational   Red     PS fault detected  User should check individual power supplies   for fault indications   SPINE FANS  Off    No power to fan Green  STATUS Green     Nominal operational   Red     One
    