Home

DS800 Development Suite Quick Start Guide for the ROC800

image

Contents

1. Complete Name field Comment o Template SingleROCSOnE af Default template Cancel Note By default DS800 places project files in the folder C Program Files Emerson Process Management Projects DS800 2 1 If you want your project files in another location click Browse to select that location 3 Enter ROC800_SampleProject1 in the Name field DS800 completes the Template field with the default value SingleROC800E a single ROC800 using Ethernet connections Note You can click V in the Template field to display other templates 4 Click OK The DS800 Resource view screen displays sz DS800 ROC800_SampleProject1 Link architecture BHR Ele Edit Insert Project Tools Debug Options Window Help 8 580 E y DS800 Toolbar 2 T gt Gmg Pro et Tree View x J UE ROC800_SampleProject1 Views Sa Link architecture E 1 Resource Resource Number a fas Toolbar i Hardware architecture y A Parameters D e kik E Binding list A Variable Groups m Config1 A Programs mu Resource 1 A Functions pal I O Wiring A Function blocks Ry Programs A Functions A Function blocks lt w 28 Issued Mar 09 DS800 Development Suite Quick Start Guide ROC800 Series Use the icons on the DS800 toolbar and the Views toolbar to work with the project data Small descriptive tags tool tips appear as you move the cursor over each toolbar icon 5 Double click the hardware a
2. Connection to the Configuration Manager failed displays refer to Troubleshooting Connections at the end of this manual 4 Proceed to Debugging the Project 8 Debugging the Project Debug mode enables you test resources while you are online The debug routine establishes a connection with the hardware and displays the current value of variables while the code executes This live view helps you to detect and remove errors Note You must have successfully downloaded a project to use debug mode To start a debugging session Issued Mar 09 53 DS800 Development Suite Quick Start Guide ROC800 Series 1 Click the Debug Target icon Lal on the toolbar The Workbench software connects to the ROC800 and includes the word RUN in the title of the Resource 1 dialog box 3 DS800 SampleProject Link architecture Seles File Edit Insert Project Tools Debug Options Window Help ES Gre et OP reir IBS ho J G Oo000 PR a 0 kK 8 gt 111 4 RUM CODE 1 Resource O Icon in title bar H P Parameters Y Variable Groups i PRY Programs 7 D i RUN in title bar Colors in L q enia resource is Y Functions ha Function blacks gt USMTNEO PASTOL pastol Resource 1 Configl Resourcel NUM 2 The green and blue icon in the upper left corner of the screen amp indicates that no errors are present Double click the Counter program to open the editor Revi
3. D5800 Runtime Emerzon FCO 0 1 0 0 Of Mo Expiration 03 04 009 1 28 07 DS800 License MEE E Mum Application Name Provider Name 4ppCode Version Quantity H valable Expiration Time Created Liquid Calc Ermerson FEO 6 1 0 0 1 1 Mo Expiration 12012005 14 26 05 License Key H2 2 AGA 37 8 Emerson FCD foon D No Expiration 09 19 2002 02 04 11 Emerson FCD No Expiration 11 16 2005 13 41 01 A Cancel Note The ROC800 displays the active DS800 Runtime license 13 Click Cancel to close this screen but do not exit ROCLINK 800 14 Proceed to Verify the Operation of the DS800 Kernel 3 Verify the Operation of the DS800 Kernel The DS800 kernel is the engine which runs inside the ROC800 and interprets and executes DS800 programs Because the kernel is part of the ROC800 Series firmware no software installation is necessary To verify the operation of the kernel 1 Click Configure gt Control gt DS800 on the ROCLINK 800 menu bar The DS800 dialog box displays showing the General tab Issued Mar 09 9 DS800 Development Suite Quick Start Guide ROC800 Series DS800 f fx Mode is On RASI Task ICPF Task IsO Task Mode F On Enabled Enabled Enabled Task is Enabled Or C Disabled C Disabled C Disabled Clea Resouces a Rinne F Punha Kernel is Running Update Y OK 7 Cancel 2 Verify that the Mode option is On This enables the DS800 kernel 3 Verify that the Run
4. Write Status ls 2 Update Y OK 7 Cancel 2 Click Save Configuration in the Flash Memory frame ROCLINK 800 displays a confirmation dialog 8 Issued Mar 09 DS800 Development Suite Quick Start Guide ROC800 Series ROCLINK 800 h P Perform Flash Memory Save Configuration 3 Click Yes ROCLINK 800 saves the configuration and displays a dialog box when it finishes ROCLINK 800 4 Click OK to close this dialog box The Flags screen displays Click OK to display the ROC800 graphic Proceed to Install the DS800 Workbench Software 6 Install the DS800 Workbench Software Issued Mar 09 The DS800 Workbench software provides the development environment you use to create DS800 projects IEC 61131 3 compliant programs which you consequently download to the ROC800 Note For more information on creating DS800 projects refer either to Create a Sample Workbench Program in this document or to the DS800 Development Suite Software User Manual Form A6126 Remote Automation Solutions delivers the DS800 Workbench software on a CD ROM Your PC must have the following minimum requirements Pentium class processor 233 MHz or greater recommended CD ROM drive Windows 2000 Service Pack 2 XP Ethernet recommended or serial port Administrative privileges for the PC on which the software is to be installed DS800 Development Suite Quick Start Guide ROC800 Series A Caution A Sentinel
5. resulting in interrupted operations When working on units located in a hazardous area where explosive gases may be present make sure the area is in a non hazardous state before performing procedures Performing these procedures in a hazardous area could result in personal injury or property damage Remote Automation Solutions delivers the DS800 runtime license on a standard ROC800 license key To install a license key 1 Remove power from the ROC800 Remove the wire channel cover Unscrew the screws from the CPU faceplate Remove the CPU faceplate a Place the license key in the appropriate terminal slot P2 or P3 in the CPU U Incorrect Correct DOC0423B Note If you are installing a single license key place it in slot P2 6 Press the license key into the terminal until it is firmly seated 7 Replace the CPU faceplate 8 Replace the screws on the CPU faceplate 9 Replace the wire channel cover 10 Restore power to the ROC80 Note The physical process of installing the license key also enables any licenses on that key 11 Log onto ROCLINK 800 4 Issued Mar 09 DS800 Development Suite Quick Start Guide ROC800 Series 12 Select Utilities gt License Key Administrator on the ROCLINK 800 menu bar The License Key Administrator screen displays License Key Administrator License Key H Num Application Name Provider Name 4ppCode Version Quantity H valable Expiration Time Created 2
6. 09 DS800 Development Suite Quick Start Guide ROC800 Series waa DS800 SampleProject Link architecture a Fie Edit Insert Project Tools Debug Options Window ETE gt 4609 x SampleProject Sa Link architecture E 1 Resource ae Hardware architecture ER P Parameters E Binding list e Variable Groups HH Configi P Programs Resource 1 R Functions JE 1 0 wiring A Function blocks A Programs P Functions A Function blocks 9 Proceed to Adding Variables to the Dictionary 3 Adding Variables to the Dictionary Once you have a configuration loaded you can begin to define variables in the DS800 dictionary Variables associate TLPs in the ROC800 with DS800 content To add variables 1 Click the Dictionary icon le on the toolbar to open the Dictionary view Issued Mar 09 35 DS800 Development Suite Quick Start Guide ROC800 Series 36 waa DS800 ROC800_SampleProject1 Dictionary Variables EH File Edit Debug Tools Options Window Help EC 1 de ee EE gt 0 00AD2B Variables 2 In the tree to the left of the screen double click Variables gt Resourcel gt Any Group gt All variables The panel in the right portion of the screen changes to a grid format ua DS800 ROC800_SampleProject1 Dictionary Variables EE File Edit Debug Tools Options Window Help CT ai EFI LL te ene ae All variables ine Jato ore i One Gp ao cespe Dein Res
7. Discrete Outputs Analog Inputs Analog Outputs Pulse Inputs System Analog Inputs b 98 0 21 UINTS2 iw 9 Leave SFP 1 as the value in the Logical Number column and select 21 Long 1 in the Parameter column TLP Browser Point Type Logical Number Parameter Undetined Float 15 System Yanables SFP 2 Float 16 Logon Parameters SFP 3 Float 17 License Ley Information SFP 4 Float 15 User E Configuration J SFP 5 5 Float 19 AOL Comm Ports SFP 6 F Float 20 FST Parameters SFP Y FST Register Tags SFP 8 35 Soft Pomt Parameters SFF 3 Configurable pcode SFP 10 Power Control Parameters SFP 11 Discrete Inputs SFP 12 Discrete Outputs SFP 13 Analog Inputs SFP 14 Analog Outputs SFP 15 Pulse Inputs TLP value 16 Access type SFP 17 UINTS2 rdw Y OK 25 Cancel 10 Finally select Write as the access type Click OK The variable dialog box displays Note that the values in several fields have changed to correspond to your defined variable Issued Mar 09 39 DS800 Development Suite Quick Start Guide ROC800 Series SFP_1_Float_1_Output SFP_1_Long_1_Output Alias Type DINT E Initial value Dimension Group Mone Attribute Scope Global Direction Output Retain Winn Address Comment TLP 98 0 21 Output UI l OK Cancel 11 Click OK to add the variable to the dictionary maa D5800 ROC800_SampleProjecti Dictionary Variables
8. Proceed to Importing a Device Configuration 2 Importing a Device Configuration Issued Mar 09 The device configuration file contains device specific information such as number of points number of meters and TLPs the DS800 application needs to appropriate place data You created a configuration file for the ROC800 in Step 4 of the installation process 1 Right click the configuration s title bar A menu displays 31 DS800 Development Suite Quick Start Guide ROC800 Series Rename Configuration Delete Configuration Edit Description Edit Project Description Properties Find Replace in POUS Check in Configuration View Configuration History 2 Select Properties The Configuration Properties screen displays Configuration Properties General Hardware Security Name Configuration Selector 3 Click the right most browse button A message box cautions you that importing a configuration may reload the entire project D5800 4 Click Yes The Select ROCLINK 800 Configuration File screen displays 32 Issued Mar 09 DS800 Development Suite Quick Start Guide ROC800 Series Select ROCLINK 800 Configuration File Look in SampleProject Config1 File name ool Files of type Configuration Files 800 Note As a default ROCLINK 800 stores configuration files in the folder C Program Files ROCLINK800 You may need to browse to this folder to locate the configuration file
9. Show updates Sort by Name EE ROCLINK 800 Size Size N Sentinel Protection Installer 7 4 2 Click here for support information To change this program or remove it from your computer dick Change or Remove Ree Snagit 7 20 19MB PA Sonic DLA 6 Sonic RecordNow Plus a Sonic Update Manager P Trend Micro OfficeScan Client a Tweak UI Click to remove the program Uniblue DriverScanner 2009 wevex id Windows Defender Windows Live FolderShare Beta 5 Windows Media Format 11 runtime 5 Windows Media Player 11 j5 Windows XP Service Pack 3 5 Click Remove Windows displays a verification dialog box asking you to verify the removal request Baa Issued Mar 09 DS800 Development Suite Quick Start Guide ROC800 Series Add or Remove Programs 1 P Are you sure you want to remove Sentinel Protection Installer 7 4 2 from your computer 6 Click Yes to continue Windows displays a number of dialog boxes as 1t removes the program If necessary the last dialog box reminds you to restart your computer Sentinel Protection Installer 7 4 2 You must restart your system forthe configuration changes made to Sentinel Protection Installer 7 4 2 to take effect Click Yes to restart now or No if you plan to restart later Note If you have several programs to remove remove all programs before you restart your computer 7 Repeat steps 3 6 for any other Sentinel drivers When you hav
10. renames the function block DGE 1 Resource Counter File Edit Tools Debug Options Window Help Cea he el cies Io mf mil ESC x F2 mu Fp E Fa Ip FS ll F6 am ESS Eats Fa E FIO ap 37 Ia AT F12 man Y 9 2 O e E al yl Ready 11 12 48 Issued Mar 09 DS800 Development Suite Quick Start Guide ROC800 Series 17 Select the variable tool F2 and move the cursor to the right of the 1 gain function block The Select variable dialog box displays MM Select variable SFP_1_Long_1_Output Type an Types f Global local Local Group an Groups z Direction E Directions Alias Type Direction SFP 1 Long 10 Out DINT Output Internal Dimension Comment TLP 98 0 21 Output Cancel 18 Select the SPF_1_Long_1 Output variable as shown above and click OK The finished block structure should look like this 19 Click the Save icon H on the toolbar to save the program 20 Proceed to Building the Program 5 Building the Program Once you complete and save your program you must build or compile it 1 Click the Build Program icon E on the editor toolbar As the program builds the Output window at the bottom of the screen notes any errors or warnings Issued Mar 09 49 50 DS800 Development Suite Quick Start Gu
11. 0 00MB 16 05MB Size Size Size Size 3 Scroll down the program list until you find software programs which begin with the word Sentinel 19 DS800 Development Suite Quick Start Guide ROC800 Series Ub Add or Remove Programs Baa Y ho Currently installed programs C Show updates Sort by Name v Change or nl one eworeur ne Al Remove 7 RealPl 3 in 6 RealPlayer Size 38 24MB B Remove Hidden Data Tool Size 0 36MB e EF ROCLINK 800 Size 53 46MB Add New 8 Seagate Report ActiveX Viewer Size 0 98MB Programs x Sentinel Protection Installer 7 4 2 Size 3 40MB SnagIt 7 Hs z D Os Sentinel program Add Remove Sonic DLA Windows l i Components Sonic RecordNow Plus jB Sonic Update Manager Q XP Trend Micro OfficeScan Client Size 76 24MB Set Program a Tweak UI Access and Defaults Uniblue DriverScanner 2009 Size 21 11MB wevex dd Windows Defender Size 65 71MB 1 Windows Live FolderShare Beta Size 1 15MB 5 Windows Media Format 11 runtime O Windows Media Player 11 i B Windows XP Service Pack 3 y Ub Add or Remove Programs 5 Change or Remove Programs ny Add New Programs Add Remove Windows Components Set Program Access and Defaults 20 i5 Seagate Report ActiveX Viewer 4 Click the program label Windows opens a program specific dialog box you use to change or remove this program Currently installed programs C
12. 800 the software requires Version 1 80 or greater of ROCLINK 800 Version 2 10 or greater of ROC800 Series firmware To verify the versions 1 Start ROCLINK 800 DS800 Development Suite Quick Start Guide ROC800 Series 2 Click Help on the ROCLINK 800 tool bar and click About ROCLINK 800 from the drop down menu The About ROCLINK 800 screen displays About ROCLINK 800 x ROCLAN ROCLINE 800 Version 1 80 aH Part Number 58730 WIAA emersonprocess com remote License Copyright FISHER CONTROLS INTERNATIONAL LLC Software Version ALL RIGHTS RESERVED CONFIDENTIAL This program ls the property of FISHER CONTROLS INTERNATIONAL LLE Its configuration and algorithm are confidential and may not be used reproduced or revealed to others except in accord with contract or other written consent of FISHER CONTROLS INTERNATIONAL LLE Any permitted reproduction in whole or in park must bear this legend Supporting Files Version Information ROC MOBE 1 80 DBSO0 MDE 1 80 Pa asFilter 0 Ex 1 5 0 0 PGas MDE 1 5 0 0 Flow alF iter DC 1 5 0 0 Flowlal MDB 1 5 0 0 EfmE sport OC 2 0 0 0 EfmE xport MOE 2 0 0 0 Build Date Monday July 07 2008 3 Verify that the version of ROCLINK 800 is 1 80 or greater Note If the version is not at least 1 80 contact your Remote Automation Solutions representative to upgrade ROCLINK 800 4 Click OK The ROC800 graphic displays Click ROC on the R
13. 88 File Edit Debug Tools Options Window Help A X i ien BARBIE RP gt e80 8 832 None Free Global Internal Ho None Read Global Input No Global variables 12 Click the Save icon H to save your changes to the dictionary 13 Click the Link Architecture view icon s to display the project s link architecture 14 Proceed to Adding a Program to the Resource 40 Issued Mar 09 DS800 Development Suite Quick Start Guide ROC800 Series 4 Adding a Program to the Resource Using the Link Architecture view you can see how the components of your DS800 project fit together The next step is to give the ROC800 resource functionality by adding a program 1 Right click Programs in the Resourcel box A menu displays 2 Move the cursor over the Add Program option to display a menu of programming languages 1 Resource SFC Sequential Function Chart Flow Chart Fo Structured Text ST LD Ladder Diagram FBD Function Block Diagram Find Replace in POUs Ctrl F IL Instruction List 3 Select FBD Function Block Diagram The Link Architecture view displays showing an unnamed FBD Issued Mar 09 41 DS800 Development Suite Quick Start Guide ROC800 Series ma DS800 ROC800_SampleProject1 Link architecture a Edit Insert Project Tools Debug Options Window Help JUANA e alo E Project Tree View ROca00_SampleProjecti ta Link architecture 1 Reso
14. C809 RESOURCE1 0 e 0 waming s z ing s ROC800_ SAMPLEPROJECT1 0 errors 0 waming s USMTNEO CETHIE cethie Resource 1 Configi Resource1 Resource 1 2 For a successful compile the Output window should display O error s O warning s 3 Proceed to Downloading the Project 7 Downloading the Project Once you have successfully compiled the project you can download it to the ROC800 for execution there Ensure that your PC is connected via an Ethernet connection to the target ROC800 the same ROC800 from which you imported your configuration file 1 Click the download icon y on the toolbar The Download dialog box displays 52 Issued Mar 09 DS800 Development Suite Quick Start Guide ROC800 Series Download Check resources to download their code Configl 1 Resourcel Toggle Select Select All Ungelect All W Save on target after download i Start after download Cancel 2 Click Select All to choose the resource you want to download For this sample project we defined only one resource You can de select any resources you want to omit them from this download 3 Click Download to start the download process When the download completes DS800 displays the following message in the Output portion of the Workbench screen Checking database O3 November 06 14 11 Download completed successtully Note If the message Error occurred during downloading to configuration
15. Form A6274 Part Number D301598X012 March 2009 DS800 Development Suite Quick Start Guide for the ROC800 Series Remote Automation Solutions EMERSON DS800 Development Suite Quick Start Guide ROC800 Series Revision Tracking Sheet March 2009 This manual may be revised periodically to incorporate new or updated information The revision date of each page appears at the bottom of the page opposite the page number A change in revision date to any page also changes the date of the manual that appears on the front cover Listed below is the revision date of each page if applicable Page Revision Initial issue Mar 09 2009 Remote Automation Solutions division of Emerson Process Management All rights reserved NOTICE Remote Automation Solutions RAS division of Emerson Process Management shall not be liable for technical or editorial errors in this manual or omissions from this manual RAS MAKES NO WARRANTIES EXPRESSED OR IMPLIED INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO THIS MANUAL AND IN NO EVENT SHALL RAS BE LIABLE FOR ANY INCIDENTAL PUNITIVE SPECIAL OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO LOSS OF PRODUCTION LOSS OF PROFITS LOSS OF REVENUE OR USE AND COSTS INCURRED INCLUDING WITHOUT LIMITATION FOR CAPITAL FUEL AND POWER AND CLAIMS OF THIRD PARTIES Bristol Inc Bristol Canada BBI SA de CV and Emerson Process Management Ltd Re
16. OCLINK 800 toolbar and click Information on the drop down menu The Device Information screen displays D Issued Mar 09 DS800 Development Suite Quick Start Guide ROC800 Series Device Information Station Mame Remote Dprtns Critrr Device Type IROCS00 Seres 1 Address Group Logical Compatibility Mode f 16 Points Per Module f Points Per Module Update Y OK A Cancel 6 Select the Other Information tab The Other Information screen displays Device Information Version Mame WEST25 Ver213 Time Created Sep 08 2008 15 57 Firmware Version Vendor ID Emerson Process Mgmt MPU Loading 78 8216 2 Boot wersion WEST27XO012 Wer1 00 Time Created Jul 30 2002 1518 Last Power Down Time 10271 9 2009 15 18 08 Last Power Up Time 02 20 2009 10 16 35 2 Update Y OK Mi Cancel 7 Verify that the firmware version for your ROC800 is 2 10 or greater Issued Mar 09 3 DS800 Development Suite Quick Start Guide ROC800 Series Note If the version 1s not at least 2 10 contact your Remote Automation Solutions representative to upgrade the firmware 8 Click OK to close the Device Information screen but do not exit ROCLINK 800 Proceed to Install the DSSOO Runtime License 2 Install the DS800 Runtime License A Failure to exercise proper electrostatic discharge precautions such as Caution wearing a grounded wrist strap may reset the processor or damage electronic components
17. T EQUAL Data Manipulation Test if one value is EQUAL TO an Process Control Test it one value is GREATER TH Inputs E 8 In the right hand panel select the second block option Addition of two or more integer or and click OK The editor changes the shape of the generic function block to an addition function block Note the two inputs on the left side of the block and one output which provides the sum on the right side of the block 44 Issued Mar 09 File Edit Tools Debug Options Window Help CRETTI re 0057 0 gt 2 LE 21 LIL ESC Y Fe mm Fa Fa In ES F6 q DS800 Development Suite Quick Start Guide ROC800 Series DGE 1 Resource1 Counter Ba ES x y F8 o FS E O F Fad FAZ my lt gt Sul 4 a E e A A ee Ready gt 15 11 9 Click the variable tool on the language toolbar or press F2 The DGE 1 Resource Counter File Edit Tools Debug Options Window Help cursor becomes a variable tool once you move it into the editor grid Hkh eo SN 8 OS TO HP jp ni J SEE X ESC Y F2 mm F3 t 3 Fa la ES la F6 q F7 yy Fe o F9 E FAO a eee ng i Fm m A E z Variable tool F2 Ready Issued Mar 09 zl gt 15 19 45 DS800 Development Suite Quick Start Guide ROC800 Series 10 Move the variable tool close to one of the inputs on the left side of the
18. USB license key provides access to all the DS800 Workbench features Do not insert the Sentinel USB license key in any USB port on your PC until directed to do so Using the key before the Workbench is completely installed may cause unpredictable results To install the software 1 Place the CD ROM into your PC s CD drive The Product Installer wizard starts automatically Note If you have Autorun enabled on your computer the Product Installer wizard starts automatically If you have disabled Autorun use this procedure to start the wizard a Click Start gt Run The Run dialog box displays b Click Browse navigate to the folder on the CD ROM containing the Workbench software and select the Setup exe file in that folder The Run dialog box displays Cc Click OK The Product Installer wizard screen displays Emerson Products Installer 2 10 Welcome to the InstallShield Wizard for Emerson Products Installer The InstallShield Wizard will install Emerson Products N Installer on your computer To continue click Next y EMERSON Process Management 2 Click Next A software license agreement displays 10 Issued Mar 09 Issued Mar 09 DS800 Development Suite Quick Start Guide ROC800 Series Emerson Products Installer 2 10 License Agreement Please read the following license agreement carefully Software License Agreement Definition The term You includes but is not limited to users of t
19. ays when you open this screen Security which sets a password security to prevent unauthorized changes to the configuration s properties Specifying a target for a configuration affects the list of functions and function blocks that you can call in your programs the list of I O devices that you can use and the networks that you can connect to your configuration The ROC800 can communicate with the Workbench the DS800 utility you use to create configurations using either the ISARSI serial network driver or the ETCP Ethernet network driver You select this through the template The Hardware Architecture view provides a reminder of what network driver you are using ETCP is the standard driver Remote Automation Solutions provides to communicate over an Ethernet network The Workbench debugger also uses ETCP to communicate with the resources running on the configurations 6 Double click the vertical connection line to open the connection configuration A Connection Properties screen displays 30 Issued Mar 09 DS800 Development Suite Quick Start Guide ROC800 Series Connection Properties Network Parameters Name Value Comment IPAddress 10 0 0 2 IP address or Computer nar 7 For an Ethernet connection configuration is automatic However you can manually modify the value of the IP address on this screen according to the ROC800 series device you intend to connect to Click OK to save the value 8
20. e uninstalled all previous versions of Sentinel drivers you can install the most current Sentinel driver To install the most current version of the Sentinel driver 1 Place the CD ROM you used to install the DS800 software in your computer s CD drive Click Start gt Run The Run dialog box displays gt Click Browse Remote Automation Solutions placed the 7 5 0 Sentinel driver in the Sentinel folder on the CD ROM Select the Sentinel System Driver Installer 7 5 0 exe file The Run dialog box displays the selected file 4 Click OK The InstallShield wizard displays Issued Mar 09 21 DS800 Development Suite Quick Start Guide ROC800 Series Contirm Upgrade Previous version detected please confirm Click Upgrade to overwrite the older version of the Sentinel System Driver or Sentinel Keys Driver found on this system Do not cancel the upgrade before the installation has completed or you may not be able to run applications that depend on the software components being installed Note If you have not removed all prior versions of the Sentinel Protection Installer the wizard detects those versions and displays this screen to ensure the upgrade of all previous versions 5 Click Upgrade The wizard displays the installation splash screen ig Sentinel system Driver Installer 7 5 0 InstallShield Wizard Welcome to the InstallShield Wizard for Sentinel System Driver Installer 7 5 0 The Installshield R Wizard wi
21. e 1 Configi Resource1 Resource 1 4 Proceed to Compiling the Project 6 Compiling the Project As noted before a project may have one or more programs Our simple project has only one program but if your project has multiple programs you need to successful compile or build each program when the Output window displays O error s O warning s Only then should you attempt to compile the project To compile the project 1 Click the Build Project Library icon E on the DS800 toolbar The Output window indicates whether any errors or warnings occurred Issued Mar 09 51 DS800 Development Suite Quick Start Guide ROC800 Series saa DS800 ROC800_SampleProject1 Link architecture SEE File Edit Insert Project Tools Debug Options Window Help a x E a220220IA gt 190 OLE Project Tree View Base Layer xd Toy ROC800_SampleProject1 gt Link architecture tet Hardware architecture g Binding list R Parameters R Variable Groups mm 1 Resource Resou e 1 Ol E lt Build Project Library m Config1 mm R Programs ICON 5 resource i a JEE 1 0 wiring R Functions R Programs P Function blocks Y Counter LS Functions R Function blocks Output window r x Checking database Build project ROC800_SAMPLEPROJECT1 Build resource RESOURCE1 Configuration CONFIG1 Compiling for ROC809 COUNTER Fi Linking for RO
22. e DS800 programs you develop will of course be more complex than this simple example But the processes you use to develop those programs are the same If you need further information on the DS800 software refer to the DS 00 Development Suite Software User Manual Form A6126 Troubleshooting Connections While attempting to download a DS800 project to the ROC800 you may see the message Error occurred during downloading to configuration Connection to the Configuration Manager failed This means that the Workbench cannot communicate with the DS800 kernel inside the ROC800 Following are some tips to help you diagnose and resolve this problem Note These solutions assume you have an Ethernet connection between the ROC800 and the PC on which the DS800 software 1s installed Can you ping the ROC800 Open up a command window Start gt Run gt cmd exe and enter the command ping nnn nnn nnn nnn where nnn nnn nnn nnn represents the IP address of your ROCS800 If you get no response then there 1s a network connection problem Does the ROC have a DS800 Runtime License Using ROCLINK 800 check if the ROC800 in question has a DS800 Runtime License Utilities gt License Key Administrator If the license is not present then DS800 projects cannot download Is the configuration connected Check using the Hardware Architecture view of the Workbench that the Configuration box representing the ROC is connected via a vertica
23. ew the real time results of the program The editor displays the block diagram showing the current value of the variables and the output of the function blocks The value increases at a rate of 10 times per second which is how frequently the code executes by default 54 Issued Mar 09 DS800 Development Suite Quick Start Guide ROC800 Series Incrementing value 4 Click the Stop Debug Target icon E on the toolbar to stop the real time display and exit Debug mode Close the editor The DS800 screen displays 5 Proceed to Verifying the Program in ROCLINK 800 9 Verifying the Program in ROCLINK 800 The final step in the process of developing a program is to access ROCLINK 800 software and verify that the program is correctly incrementing the soft points you have targeted 1 Disconnect from DS800 2 Connect to the ROC800 using ROCLINK 800 3 Select Configure gt I O gt Soft Points from the ROCLINK 800 menu bar The Soft Point screen displays MM Soft Point Softpoints Ma TAT TTT TTT r E 2 Ce Auto Scan Update Y OK A Cancel Issued Mar 09 55 DS800 Development Suite Quick Start Guide ROC800 Series 4 Note the value in the Integer field Click Update several times over 5 10 seconds and watch the value increase This indicates that the DS800 program is incrementing that value 10 times per second as you intended Summary To meet the needs of your organization th
24. function block and click The Select Variable dialog box displays which shows the variables currently defined for this project MM Select variable Type E Types f Global local f Local Defined variables E Groups z Direction E Directions Mame Alias Type Director Dimension Comment SFF_1 Long 1 0 Out DINT Output TLF 98 0 21 Output Total DINT Internal 11 Select the Total variable and click OK The editor renames the variable and 1f the variable 1s close to the function block automatically links the variable and function block DGE 1 Resource1 Counter File Edit Tools Debug Options Window Help o x BR XO Bee SB A BOO F ORF a EE ft 00 v l ESC Y F2 mm g E Fa lad FS ll FS que ES F8 F9 E ASS DON SL F12 man oa SS A e A RT Renames and links variable to function block 12 12 46 Issued Mar 09 DS800 Development Suite Quick Start Guide ROC800 Series 12 Select the variable tool again and click near the second input on the function block to display the Select variable dialog box 13 Enter 1 in the upper left most field in the Select variable dialog box and click OK Note This value 1s not a variable but 1s a constant value 14 Select the variable tool a third time but click near the output on the function block When the Select variable dialog box displays select the Total variable and click OK At this point the program
25. he Fisher Controls International LLC Fisher product embodied in the computer program s herein the user s employer the employer s wholly owned subsidiaries parent company agents employees contractors and sub contractors The term License Agreement refers to one of FISHER s License Agreements including but not limited to all Software License Agreements accompanying FISHER products all Beta Test Agreements and all Master License Agreements Any and all use of this product is subject to the terms and conditions of the applicable License Agreement The terms and conditions of the applicable 2 accept the terms of the license agreement do not accept the terms of the license agreement 3 Read the entire DS800 software license agreement If you agree to the terms of the license select I accept the terms of the license agreement and click Next A Select Features screen displays Emerson Products Installer 2 10 Select Features Select the features setup will install The checked components shall be installed Be Development Suite 500 i o Description E LicenseM anager The environment in which pou develop multi process control applications made up of virtual machines running on hardware components 4 Use this screen to select the two DS800 features you must install Development Suite 800 Also known as the Workbench this 1s the development 11 DS800 Development Suite Quick Start Guide ROC800 Se
26. her programs which use the SafeNet Sentinel driver To uninstall prior versions of the Sentinel driver Note Before you update any drivers close all applications such as DS800 Development Suite which may require a USB license key 1 Open the Windows Control Panel click Start gt Settings gt Control Panel 2 Double click Add or Remove Programs Windows builds a list of all programs currently installed on your computer Add or Remove Programs cer Change or Remove Programs Add New Programs Add Remove Windows Components O Set Program Access and Defaults Issued Mar 09 Currently installed programs and updates Show updates Sort by v 6 04Q014 HART Calibration To change this program or remove it from your computer dick Change Remove 7 Zip 4 57 is Adobe Acrobat Reader 6 0 2 Update Adobe Acrobat 8 1 2 Professional 4 Adobe Acrobat 8 1 2 Security Update 1 KB403742 Adobe AIR bt Adobe Atmosphere Player for Acrobat and Adobe Reader ES Adobe Flash Player Activex GY Adobe Ilustrator 10 Click here to scroll Ga Adobe RoboHelp 6 0 down the program list a Allway Sync version 8 2 1 a ALPS Touch Pad Driver Amazing Slow Downer remove only gt Apple Mobile Device Support E Apple Software Update E ATI Software Uninstall Utility Seis Size 0 20MB Used rarely Change Remove Size 2 86MB Size 5 64MB Size 1 101 00MB Size 113 00MB Size 28
27. ide ROC800 Series DGE 1 Resource1 Counter BAR E File Edit Tools Debug Options Window Help ox HADOS gt aM 6 OO RAP E 100 fa ESC y Y F2 ee e g F In FS ll FS Fr gt FS o AF IE F10 yp g A F12 al qa e ee Build Program icon Output window Note The Output window shows the result of the code generation During testing it can also show any execution messages You can change the height of the window to display more or fewer lines 2 When the build completes the message in the Output window should resemble the following Checking database Check POU RESOURCE Compiling for ROC809 UNTER 0 eroris O waming s Compiling for SIMULATOR COUNTER 0 eroris O waming s Output Ready 3 Close the editor window The main workbench window displays Issued Mar 09 DS800 Development Suite Quick Start Guide ROC800 Series DS800 ROC800_SampleProject1 Link architecture Ele Edit Insert Project Tools Debug Options Window Help sh xo i KIK ID lea E gt See CEEI Project Tree View x ROC800_SampleProject1 gt Link architecture 1 Resource1 Resource 1 2 Hardware architecture A Parameters o ie E Binding list P Variable Groups Cn an A Programs mu Resource 1 Jem JEE 1 0 wiring A Functions A Programs A Function blocks x Counter A Functions A Function blocks USMTNEO CETHIE cethie Resourc
28. ination Folder C Program Files E merson Process Management InstallShield Cancel 8 Click Next to accept the default location or click Browse to select another location Issued Mar 09 13 DS800 Development Suite Quick Start Guide ROC800 Series Note If you have inserted the Sentinel USB license key in your computer remove it BEFORE you click Next 9 The wizard begins installing the first component the DS800 Workbench DS800 2 10 Setup Status EMERSON Frogs Vi appt t DS800 2 710 305 is configuring pour new software installation Installing Product files CA Emeron Process Management DS800 2 1 Binicvs exe 10 When the installation of the Workbench completes the wizard prompts you to include an icon on your desktop Installation process is irreversible after starting 25800 Development Suite Oey Peppy Embedded Control Software Question Would you like to place a shortcut to the product directory on your desktop tes 0 2002 2007 Remote Automation Solutions All rights reserved EMERSON Process Wingi inal 14 Issued Mar 09 DS800 Development Suite Quick Start Guide ROC800 Series 11 Click either Yes or No to continue The wizard begins installing the second component the LicenseManager LicenseManager 2 10 Setup Status EMERSON Proa W ajeno LicenseM anager 2 10 304 is configuring your new software installation CA ADS5800 21535081 D4C Window
29. ion of this document 4 Click Start gt Programs gt Emerson Process Management gt DS800 2 1 again select the application and not the folder The splash screen displays followed by the DS800 screen sai DS800 AE Help File He See PATIENT MARS OS PIPlY we No banner at bottom of screen indicates DS800 has recognized the license key Note This version of the DS800 screen does not have a red banner across the bottom of the screen This means that DS800 detected the license key and changed the Workbench functionality accordingly If the DS800 still has a red banner proceed to Troubleshooting the Installation in this document 5 You can begin to develop DS800 projects Refer to Creating a Sample Workbench Project in this guide Troubleshooting the Installation The DS800 Development Suite software and the USB Sentinel license key use Sentinel Protection from SafeNet Incorporated Other software vendors today use the same technology so if Windows does not recognize an attached USB license key it s possible that conflicting versions of the SafeNet Sentinel software are installed on your computer To resolve this conflict you must uninstall all versions of the Sentinel driver from your computer and install the latest version The updated 18 Issued Mar 09 DS800 Development Suite Quick Start Guide ROC800 Series driver allows Windows to recognize the USB license key and does not adversely affect any ot
30. l applications You can distribute these applications across several platforms or enable the applications to communicate with each other through networks A DS800 project shows the distribution and links between each PLC loop which the DS800 kernel or virtual machine executes on each platform Using the function block diagram language this section details the steps required to build a sample project creating an incrementing counter in a soft point parameter and familiarizes you with the views buttons and vocabulary of DS800 The following steps are involved Creating a New Project Importing a Device Configuration Adding Variables to the Dictionary Creating a Program to the Resource 4 2 3 4 5 Compiling the Program 6 Compiling the Project 7 Downloading the Project 8 Debugging the Project 9 Verifying the Program in ROCLINK 800 1 Creating a New Project Issued Mar 09 To create a new DS800 project 1 Click the DS800 2 1 icon on your desktop The DS800 workspace screen displays Note If you did not create a desktop icon for this application you _ can also click Start gt Programs gt Emerson Process A AE e aaa 2 Click the New Project icon on the DS800 workspace toolbar A New project dialog box displays 21 DS800 Development Suite Quick Start Guide ROC800 Series Destination folder C Program Files Emerson Process Managemer Browse Mame ROCBOO_S ampleProjectl
31. l line to the ETCP network Does the configuration in the project have the right IP address Check that the IP address in the DS800 Hardware Architecture view connection properties is the same IP address you see in ROCLINK 800 ROC gt Information gt Internet 56 Issued Mar 09 Issued Mar 09 DS800 Development Suite Quick Start Guide ROC800 Series Are you comnecting to the correct device Unplug the Ethernet cable from the ROC800 and try to ping the ROC If you still get a response then you do not have the correct IP address Is the DS800 kernel inside the ROC running Go into the ROCLINK 800 DS800 configuration Configure gt Control gt DS800 and ensure that the DS800 switch is turned on Press Update several times to make sure Are the three associated tasks Running See 3 Verify Operation of the DS800 Kernel Have you accidentally created a Library Project Does a CD and Book icon display in the lower right corner of the Resource view of the Workbench If so you ve accidentally created a library which is not downloadable to a ROC800 You ll need to create a new project with the template SingleROCS00E 57 DS800 Development Suite Quick Start Guide ROC800 Series 98 Issued Mar 09
32. ll install Sentinel System Driver Installer 7 5 0 on your computer To continue dick Next WARMING This program is protected by copyright law and international treaties 6 Click Next A license agreement screen displays 22 Issued Mar 09 DS800 Development Suite Quick Start Guide ROC800 Series Issued Mar 09 License Agreement Please read the following license agreement carefully License Grant Warranty for Software This License describes limited rights granted by SafeNet Inc and or one of its subsidiaries such grantor Seller to the Buyer A The term Software as used herein shall mean a program or programs consisting of machine readable logical instruction and tables of information designed as libraries or drivers to work in conjunction with Seller s Sentinel Keys PProducts Title to all Software furnished to Buyer hereunder shall rome oie D alla D allae mr bin Daas nmr m mmm mnnm ha amn res mi om m kran tarall 7 Select I accept the terms in the license agreement and click Next The wizard displays a screen for the type of setup Setup Type Choose the setup type that best suits your needs Please select a setup type All program features will be installed Requires the most disk space Choose which program features you want installed and where they will be installed Recommended for advanced users 8 Select Complete and click Next The wizard displays a screen used to
33. mote Automation Solutions division UK are wholly owned subsidiaries of Emerson Electric Co doing business as Remote Automation Solutions RAS a division of Emerson Process Management ROC FloBoss ROCLINK Bristol Bristol Babcock ControlWave TeleFlow and Helicoid are trademarks of RAS AMS PlantWeb and the PlantWeb logo are marks of Emerson Electric Co The Emerson logo is a trademark and service mark of the Emerson Electric Co All other trademarks are property of their respective owners The contents of this publication are presented for informational purposes only While every effort has been made to ensure informational accuracy they are not to be construed as warranties or guarantees express or implied regarding the products or services described herein or their use or applicability RAS reserves the right to modify or improve the designs or specifications of such products at any time without notice All sales are governed by RAS terms and conditions which are available upon request RAS does not assume responsibility for the selection use or maintenance of any product Responsibility for proper selection use and maintenance of any RAS product remains solely with the purchaser and end user ji Issued Mar 09 Introduction DS800 Development Suite Quick Start Guide ROC800 Series The DS800 Development Suite software DS800 is an integrated development environment that allows you to build IEC 61131 3 compliant prog
34. ning checkbox in each of the three task areas is checked This confirms that the runtime kernel 1s executing Note Installing the license key should correctly set these fields If the checkboxes are not selected perform a warm start and re check the License Key Administrator to make sure the DS800 license is installed 4 Click OK Proceed to Create Configuration File 4 Create Configuration File Creating a configuration 800 file preserves the I O configuration you have defined on your ROC800 The DS800 Workbench software uses this configuration file and its defined point types to correctly map information you define in the Workbench back to your ROC800 To create a configuration file 1 Click File gt Save Configuration on the ROCLINK 800 menu bar A Save As dialog screen displays 6 Issued Mar 09 DS800 Development Suite Quick Start Guide ROC800 Series Save Ir ROCLINK80D do Pal yo Recent Documents aaa z Desktop My Documents My Computer My Hetwork Places Issued Mar 09 C Configurations Displays 9 ROocso0 Log Tool a DFIE103 800 a DFI1031 800 a FastHistory 800 a FB107config 800 2 FB107default 800 2 FloBoss 407 Default 800 Ej FloBoss 503 10 pt Default 800 Ej FloBoss 503 24 pt Default 800 Ej PloBoss 504 10 pt Default 800 Ej FloBoss 504 24 pt Default 800 a ROC312 Default 800 4 ROC364 Default 800 a pocadOdefault 800 4
35. only contain a single configuration hardware unit a single resource and are limited to 128 points of I O The PRD license key also enables you to use Workbench to create and edit an unlimited number of projects However PRD created projects can contain an unlimited number of configurations hardware units define up to 4 resources per unit and have an unlimited number of I O points You can distribute PRD created projects across multiple devices A trial version of Workbench 1s also available The trial version has the same features as a PRD license but it operates for only 30 days After 30 days the trial expires and you must uninstall the software Any projects you may have created with the trial version require a copy of Workbench with a PR2 or PRD license key Contact your local Remote Automation Solutions representative to receive a copy of the trial version of Workbench Hardware Units Resources per Supported Hardware I O Points Notes Technician Unlimited 4 Unlimited Cannot create or edit projects PR2 1 1 128 PRD Unlimited 4 Unlimited Trial Unlimited 4 Unlimited Expires in 30 days Technician mode is basically a read only mode You cannot create new projects or edit previously created projects but you can view existing projects and download projects 26 Issued Mar 09 DS800 Development Suite Quick Start Guide ROC800 Series Getting Started with DS800 The DS800 workbench is designed to help you build process contro
36. ource 1 Config1 E Any Group F Global variables Double click the blank row 3 Double click the blank row to open a dialog box that helps you to define the new variable Issued Mar 09 DS800 Development Suite Quick Start Guide ROC800 Series Alias Initial value Type BOOL Y E Dimension Group None Attribute Fee y Scope Global y Direction lIntemal Retain ho Wiring fo Address Poo Comment fo ma Cancel 4 Enter Total in the Name field and select DINT signed double integer in the Type file Hame Total l Group None Alias Initial value Dimension fo Attribute Fee Scope Gleba y Direction Intemal x Retain ho We nig Lf Address Po Comment fo Po OF 5 Click OK to add the variable The Dictionary screen redisplays with the variable added wa D5800 ROC800_SampleProject1 Dictionary Variables EH File Edit Debug Tools Options Window Help ape Tie lire ecco gt gmuo 09 AB All variables Spreadsheet view button Name Alias Type Initial va Dimensi Group Attribute Scope Direction Retain ba Resource1 Config Total DINT None Free Global Internal No E Any Group Added variable Issued Mar 09 37 DS800 Development Suite Quick Start Guide ROC800 Series Note Click the button in the upper right corner of the variable view to display the variable table in an editable spreadsheet format 6 To define a
37. rams You install DS800 on your PC and use the software to develop programs and download those programs using an Ethernet connection to the ROC800 Series device ROC800 Note For further technical information refer to the specification sheet DS800 Development Suite Software 4 1 D5800 This Quick Start Guide provides both a high level overview and the detailed steps you need to install and configure the DS800 software on your PC It also provides a very simple example of building an IEC 61131 3 compliant program The installation process requires you to Verify versions of ROCLINK 800 and the ROC800 firmware Install the DS800 Runtime License in the ROC800 Verify the operation of the DS800 kernel in the ROC800 Create a configuration file which the DS800 software uses Save the ROC800 Flash configuration Install the DS800 Workbench software DS800 Development Suite and LicenseManager on your PC Oy OY oe e Ie m 7 Verify the successful installation Note To understand all the steps and system requirements we suggest that you read through this entire guide before you begin the installation and configuration process After you have successfully installed the software review Creating a Sample Workbench Project for a detailed example of building a simple IEC 61131 3 program 1 Verify Versions of ROCLINK 800 and ROC800 Issued Mar 09 When using DS800 Development Suite software version 2 1 with the ROC
38. rchitecture icon CP on the Views toolbar to display the Hardware Architecture view wa DS800 ROC800_SampleProject1 Hardware architecture 5 File Edit Insert Project Tools Debug Options Window Help 9 a A q gt 8 2 Project TreeView x ROC800_SampleProject1 gt Link architecture tr Hardware architecture E sincing ist y i Resource M Configi S Resource 1 al I O Wiring Ry Programs A Functions A Function blocks Driver Resource A resource is composed of programs and corresponds to a PLC loop You compile a resource and then download its code to configuration where the DS800 kernel virtual machine executes it Configuration A hardware platform linked to other hardware platforms by a serial network Use DS800 s Hardware Architecture view to display configurations Target You attach a configuration to a specific target A target contains definitions about the hardware platform and the virtual machine running on it Double click the configuration s title bar to display a Configuration Properties screen which has three tabs Issued Mar 09 29 DS800 Development Suite Quick Start Guide ROC800 Series Network Configuration Properties General Hardware Security Cancel General which provides a title and any comments for the configuration Hardware which indicates the target device such as the ROC809 for this configuration This is the tab that displ
39. ries environment you use to create view and download custom control applications to the ROC800 LicenseManager Supports the USB Sentinel license key which is required to access all Workbench features You also use this utility to transfer licenses and update existing license keys Note The wizard selects these two features as defaults 5 Click Next review screen displays Emerson Products Installer 2 10 Review installation settings rene Setup has enough information to start installing the product components If you want to review or change any settings click Back If you are satisfied with the settings click Next to begin installing Components Current Settings Development Suite 800 LicenseM anager 6 Review the options you have selected for installation and click Next The DS800 initial or splash screen displays 12 Issued Mar 09 DS800 Development Suite Quick Start Guide ROC800 Series Installation process is irreversible after starting 2002 2007 Remote Automation Solutions Al rights reserved Installshield Note Once you begin the DS800 installation process you cannot stop it until it completes 7 Click Install The wizard prompts you to select the location for the installed software DS800 2 10 Emerson Process Management Product Installation Path To install to this folder click Next To install to a different folder click Browse and select the folder Dest
40. roca27_samplez 800 i rocez7_sample 800 File name Cancel 2 Complete the File name field with a meaningful file name here Test09 30 2008 Click Save ROCLINK 800 displays a dialog box that shows the progress of the save Save as type Note By default ROCLINK 800 places all configuration files in the ROCLINK800 folder on your PC Save Configuration File C Program FilesSROCLINE GOO Test09 30 4008 500 Status Saving 96 Soft Point Parameters Point Number 6 Point Type LITT TTT TT A change in the Status message indicates when the process finishes DS800 Development Suite Quick Start Guide ROC800 Series save Configuration File C Program Files ROCLINKS00 7 est09 30 2008 800 Status Save configuration COMPLETED Point Type FST Version Info and Code NS Font Humber 4 Save completed 3 Click Close to complete the process The Save Configuration dialog box closes and displays the ROC800 graphic Proceed to Save Flash Configuration 5 Save Flash Configuration Saving the Flash configuration in your ROC800 is a precautionary step 1 Select ROC gt Flags The Flags screen displays Restart Restore Configuration wam Stark From Factory Defaults Cold Start Clear Cold Start amp Clear Alarms History Configuration amp Data Cold Start amp Clear Events Flash Memory Cold Start amp Clear FSTs Save Configuration Cold Start amp Clear History Data el a Flash
41. second variable that is connected to a parameter in the ROCS800 double click the highlighted blank row to open the dialog box 7 Click the TLP browse button on the dialog box Name Alias Type BOOL ES ll Initial value Dimension Group Hone Attribute Free Scope Global hil Direction Internal r Retain IN aue TLP browse Address Comment E button ox Cancel A TLP Browser screen displays TLP Browser Point Type Logical Number Parameter System Yanables Logon Parameters License Fey Information User E Configuration AOL Comm Ports FST Parameters FST Register Tags Soft Point Parameters Configurable Opcode Power Control Parameters Discrete Inputs Discrete Outputs Analog Inputs Analog Outputs Pulse Inputs System Analog Inputs Undefined ma e Read C write 8 Select 98 Soft Point Parameters in the Point Type column The program completes the Logical Number and Parameter columns 38 Issued Mar 09 DS800 Development Suite Quick Start Guide ROC800 Series TLP Browser Point Type Logical Number Parameter Undetined Float 15 System Yanables Logon Parameters License Fey Information User E Configuration AOL Comm Ports Float 16 Float 17 Float 18 Float 19 Float 20 FST Parameters FST Register Tags 36 Soft Pont Parameters Configurable Opcode Power Control Parameters Discrete Inputs
42. should look like this File Edit Tools Debug Options Window Help SH eo 8 ME OF TA ESC F2 pm FE lena el F6 fa gt _ E aro 37 lt gt pmj p Inputs From e Logi T Output Draw Link tool ee az El a Ready 5 12 the function block select the Draw Link tool F4 to connect the variables Alternately you can move the variables closer to the function block A text based equivalent for this program would be Total Total 1 Once you have defined the program you need to write the output to a parameter in the ROC800 15 Select the function block tool or click F3 and click at the extreme right hand end of the current block structure The Select Blocks dialog box displays Issued Mar 09 47 DS800 Development Suite Quick Start Guide ROC800 Series MS Select Blocks SSE SE Blocks Parameters Type Comment User Defined OFE Multiplication of two or more intege fl OFE Addition of two or more integer or T aliens OPE Subtraction of teo integer or real W Boolean operations OPE Divizion of two integer or real varia ana cslions qair 0 Assignment A Comparators Test fone value is LESS THAN a Counter Test if one value is LESS THAN o ata conversion Test if one value ls NOT EQUAL Data Manipulation Test if one value is EQUAL TO an Process Control Test if one value ls GRESTER TH 16 Select the 1 gain function block as shown above and click OK The editor
43. slnstaller KBS33803 v2 x86 exe 12 When the installation of the LicenseManager completes the wizard prompts you to include an icon on your desktop Installation process is irreversible after starting 195000 Development Suite ee ECE Embedded Control Software Question Would you like to place a shortcut to the product directory on your desktop DAN 2007 iamnow Automation faktam Aripi erd EMERSON Foira Klimp J Ai lt Back ay Corea 13 Click either Yes or No to continue The wizard prompts you to restart your computer Issued Mar 09 15 DS800 Development Suite Quick Start Guide ROC800 Series Emerson Products Installer 10 305 InstallShield Wizard Complete The InstallShield Wizard has successfully installed Emerson Products Installer Before you can use the program you must restart pour computer A SS AAA Y Yes want to restart my computer now Process Management O No will restart my computer later Remove ary disks from their dives and then click Finish to complete setup Note Until you restart your computer do not start the DS800 application 14 Proceed to Verify the DS800 Workbench Installation 7 Verify the DS800 Workbench Installation Remote Automation Solutions distributes the DS800 Workbench license on a Sentinel USB key with a blue label Note During this verification process you are instructed to insert this Sentinel USB license key in
44. stallShield Wizard installs Sentinel System Driver Installer 7 5 0 This may take several minutes status 11 As the installation proceeds the wizard displays a progress indicator When the installation finishes the wizard displays a completion screen InstallShield Wizard Completed The InstallShield Wizard has successfully installed Sentinel System Driver Installer 7 5 0 Click Finish to exit the wizard 12 Click Finish to exit the installation wizard 25 DS800 Development Suite Quick Start Guide ROC800 Series Creating a Sample Workbench Project The DS800 Workbench software provides the development environment you use to create DS800 projects IEC 61131 3 compliant programs which you consequently download to the ROC800 The functionality in the DS800 Workbench varies depending on the license key installed With no license key installed Workbench runs in Technician mode Technician mode can be considered read only mode You cannot create a new project or edit previously created projects You can view existing projects and download them into the ROC800 When the software 1s running in Technician mode a red banner appears across the bottom of the window reading Technician version for DS800 users only Two license keys PR2 and PRD allow full use of Workbench The PR2 license key enables you to use Workbench to create and edit an unlimited number of projects However PR2 created projects can
45. start the actual installation 23 DS800 Development Suite Quick Start Guide ROC800 Series Ready to Install the Program The wizard is ready to begin installation Click Install to begin the installation If you want to review or change any of your installation settings click Back Click Cancel to exit the wizard Windows Firewall detected Important Hote The setup program will install Sentinel Protection Server and Sentinel Keys Server on this system To allow accessing the Sentinel keys attached to this system by clients on the network your firewall settings will be modified This will not affect the existing security settings of this system Do you want to modify these settings right now Tip To modify these settings in future refer to the steps provided in the Help provided with this software a N g ial lad hi l l 10 The DS800 does not include the ability to access Sentinel license keys from a remote machine If you are aware of any installed software on your computer which requires this functionality click Yes Otherwise click No The wizard begins installing the software based on your selections 94 Issued Mar 09 Issued Mar 09 DS800 Development Suite Quick Start Guide ROC800 Series i Sentinel System Driver Installer 7 5 0 InstallShield Wizard f lx Installing Sentinel System Driver Installer 7 5 0 The program features you selected are being installed Please wait while the In
46. urce Resource 1 ii Hard chitectu ardware archil re EE Parameterz ad BR Variable Groups ae Programs e Be ny ane E IfO Wiring Pr H nA TS E Function blocks Function blocks 4 Rename the UntitledFBD program as Counter 5 Double click the Counter program to open the DS800 Editor program 42 Issued Mar 09 Issued Mar 09 DGE 1 Resour DS800 Development Suite Quick Start Guide ROC800 Series ce1 Counter File Edit Tools Debug Optio ns Window Help y x BH t gt SMi El LLE ES 100 v ESC F2 F3 J Fa Ind FS ll F6 ou ES F8 o FS a F10 4k PO F12 a ae SSS SSS A SSS Se ae Function block tool F3 14 0 6 Click the function block tool on the language toolbar or press F3 The cursor becomes a function block tool once you move it into the editor grid 7 Move the cursor in the middle of the editor screen and click A Select Blocks screen displays 43 DS800 Development Suite Quick Start Guide ROC800 Series MS Select Blocks Blocks Parameters Type Comment User Defined OPE Multiplication of two or more intege Alarms Addition of two or more Integer or T ale Subtraction of two integer or real V Boolean operations Division of tyg integer or real vara menes Assignment of one variable into an Comparators Testibone value is LESS THAN a Counter Test if one value is LESS THAN o Data conversion Test if one value is NO
47. you want 5 A dialog box displays that you use to select the configuration file to import Select ROCLINK 800 Configuration File Look m ROCLINKeno e C Configurations Ej Rocabodefault 500 Displays 2 ROC827_sample 800 My Recent SjROCSoo Log Tool a ROC827_sample 800 Documents ai pFt103 800 E 3 DFIELO3i 800 a FastHistory 800 a FE107config 800 a FB107default 800 a FloBoss 407 Default 800 Ej FloBoss 503 10 pt Default 800 E FloBoss 503 24 pt Default 800 an Ej FloBoss 504 10 pt Default 800 E FloBoss 504 24 pt Default 800 a ROC312 Default 800 a ROC364 Default 800 My Documents My Computer My Network File name Test09 30 2008 800 Places Files of type Configuration Files 800 Cancel Issued Mar 09 33 DS800 Development Suite Quick Start Guide ROC800 Series 6 Select a file and click Open A message box may display if the Workbench changes the IP address for the configuration to the value stored in the configuration file A IP Address set to Parro AAT OK 7 Click OK The Configuration Properties screen displays with the configuration you have selected Configuration Properties General Hardware Security Name Comment Test09 30 2008 800 in C Program Files ROCI Use bitmap ie Disabled 8 Click OK to apply the configuration file to the project Once the file is loaded DS800 displays the Resource view 34 Issued Mar
48. your computer Do not insert the Sentinel USB license key into a USB port on your computer until directed to do so To start Workbench 1 Click Start gt Programs gt Emerson Process Management gt DS800 2 1 select the DS800 2 1 application not the folder A splash screen indicating the version number and build date for the software displays briefly and then closes to display the DS800 screen Issued Mar 09 Issued Mar 09 DS800 Development Suite Quick Start Guide ROC800 Series 175800 Development Suite lEG61131 Embedded Control Software 2002 2007 Remote Automation Solutions A rights reserved EMERSON Process Management 21 Mar 12 2008 lt a DS800 read only Sele File Help GEAR ARE A BA 72072350 TPP 13500 Red banner at bottom of screen indicates Technician read only mode The red banner at the bottom of the DS800 screen indicates that the software successfully installed but was unable to find the license key Exit the application select File gt Exit on the DS800 menu bar Insert the Sentinel USB license key into a USB port on your computer Windows automatically recognizes the USB device and displays a recognition message in the System Tray eee x Your new hardware is installed and ready to use 17 DS800 Development Suite Quick Start Guide ROC800 Series Note If Windows does not automatically recognize the USB device proceed to the Troubleshooting sect

Download Pdf Manuals