1. 3 SDI VGA To set output port as SDI or VGA Cannot output two signals at the same time INPUT OUTPUT SET gt Go to SDI VGA by pressing A V buttons gt Press 4 gt buttons to set the output port as VGA SDI 5 4 4 CVBS To set the format of output video signal Set as NTSC in Korea INPUT OUTPUT SET gt Go to CVBS by pressing A V buttons gt Press b 4 buttons to select NTSC PAL 5 5 DISPLAY SET DISPLAY SET CH TITLE ON DATE amp TIME ON BORDER LINE ON SEQUENCE MODE CH 1 gt 2 gt 3 gt 4 gt SEQUENCE TIME O3 SEC 78 T5 T2999 Tt RI T RR ED H3 4 03 5 5 1 CH TITLE To set the channel name indication DISPLAY SET gt Go to CH TITLE by pressing A V buttons gt Press P buttons to select ON OFF 5 5 2 DATE amp TIME To set the current date and time indication DISPLAY SET gt Go to DATE amp TIME by pressing A V buttons gt Press gt buttons to select ON OFF 5 5 3 BORDER LINE To set the outer border line of each channels in Quad mode DISPLAY SET gt Go to BORDER by pressing A V buttons gt Press b buttons to select ON OFF 5 5 4 SEQUENCE MODE To display the screen in auto sequence mode according to the dwell time adjusted in each channel To set the SDI HDMI switching mode and CH1 CH4 switching mode DISPLAY SET gt Go to SEQUENCE MODE by pressing A V buttons gt Press lt 4 gt buttons to set CH1 gt 2 gt 3 gt 4 gt or SDI lt
2. time Second 1 99 sec 5 3 7 LOSS To set the detection of Video LOSS SYSTEM SET gt Go to LOSS by pressing A V buttons gt Press 4 amp 4 buttons to select ON OFF 5 3 8 EVENT SAVE To save the event time in the EVENT LIST when ALARM LOSS occurred SYSTEM SET gt Go to EVENT SAVE by pressing A V buttons gt Press 4 gt buttons to select ON OFF 5 3 9 EVENT CLEAR To delete all the history of event in EVENT LIST SYSTEM SET gt Go to EVENT CLEAR by pressing A V buttons gt Press b 4 buttons to select ON OFF 5 3 10 DEFAULT ALL To initialize the value and the menu will be set to default mode SYSTEM SET gt Go to DEFAULT ALL by pressing A V buttons gt Press b 4 buttons to select ON OFF 5 4 INPUT OUTPUT SET INPUT OUTPUT SET INPUT 1920x10801 60Hz OUTPUT 1920x1080p 60Hz SDI VGA SDT CVBS NTSC TS ZAM a K seLeEctT ESTO A 301 5 4 1 INPUT To set the display input format INPUT OUTPUT SET gt Go to INPUT by pressing A V buttons gt Press M 4 buttons to set the input resolution out of 1024x768p60 1280x720p 24 25 30 50 60Hz 1920x1080 50i 60i 24p 25p 30p 5 4 2 OUTPUT To set the video resolution outputted from HDMI SDI VGA When you connect SC HD04Q with the monitor set the resolution as the monitor supports INPUT OUTPUT SET gt Go to OUTPUT by pressing A V buttons gt Press 4 gt buttons to set the output resolution 10 5 4
3. 360x768p 60 1600x1200p 60 1440x900p 60 1680x1050p 60 Inserting up to 16 characters alphabet and or numbers 5 SETUP MENU e How to setup the Menu Press Menu button on front and the menu will be displayed x Please refer to the button function of SC O4HDS in front side 3 1 1 5 1 Menu Structure In menu setting mode it is possible to set up system input output display Date time channel and menu structure is displayed as below ra G SA 6 CHANNEL IN DEFAULT TITLE DATE FORMAT LOCATION DATE SET TIME SET SYSTEM ID BAUDRATE ALARM I O ALARM HOLD BUZZER OUT SYSTEM SET INPUT OUTPUT SET DISPLAY SET DATE TIME SET CHANNEL SET EVENT LIST CH TITLE DATE amp TIME BORDER LINE SEQUENCE MODE SEQUENCE TIME INPUT OUTPUT 5SDIWVGA CVBS SYSTEM EVENT LIST Us SETUP MENU s DISPLAY SET DATE TIME SET CHANNEL SET BUZZER TIME LOSS EVENT SAVE EVENT CLEAR DEFAULT ALL INPUT OUTPUT SET 5 2 SETUP MENU SETUP MENU SYSTEM SET INPUT OUTPUT SET DISPLAY SET DATE TIME SET CHANNEL SET EVENT LIST V0 20 110527 7 ZEIT 299999 Ra AI C RR EX A Button on front Press the Menu Press ENTER to select the mode by pressing AY buttons gt Press ESC to cancel or go back the previous menu 5 3 SYSTEM SET SYSTEM SET SYSTEM ID 601 BAUDRATE 9600 ALARM 1 0 ON ALARM HOLD Q3 SEC BUZZER O
4. 920x1080 1280x720P ALARM INPUT OUPUT Connect the alarm input output port to control the split display screen by connecting a sensor or switch from outside Display mode per Foreign Alarm Input External input Display mode IN1 IN2 IN3 IN4 0 O O O NormalMode 1 O O O CH1 Full Display pO 1 O O CH2FullDisplay J 0 O 1 O jCH3FulDiplay J O0 O O 1 CH4FullDisplay J4 X Input OFF mode z O Input ON mode 1 The GND and the Inx produce a short circuit X When an Alarm is entered an A appears in the video which have received the alarm in the place in which the channel loss is indicated The Alarm input will not operate if an alarm signal is entered into a lost channel 8 1 Alarm Input amp Button Function In Alarm input mode or external data control model you can only enter to the menu mode and other function button may not operate During the Alarm Hold Time press any button to escape from Alarm mode 8 2 Alarm Input Cancel When the external control data or Alarm input is eliminated it returns to the last display mode which has been displayed before the external data has entered after the Alarm Hold Time is ended You can set the Alarm Hold Time in the Alarm Time menu in System Display SETUP MENU 8 3 Alarm Input Timing Structure When the Alarm or the external data is in the screen is displayed and the buzzer operates as following t
5. Do not subject the product to physical shock or exert excessive force to operate the product Do not use the device when any smoke or smell is produced from the unit It may be subject to fire or electric shock If any smoke or smell is produced please turn off the unit and remove the power cable immediately and contact your distributor to check the device properly If the power does not turn ON please check whether the power cable is connected correctly or not If the device does not work properly please contact your distributor 1 Introduction 1 1 Overview SC HDO4Q Full HD Digital Splitter offers a high resolution display for video signals received from 4 of SDI HDMI HD with 1920 1080 pixel And it splits the screen in various formats from full screen to 4 screens display mode without deterioration Also it displays the video clearly in a Full HD monitor with 1920 1080P high resolution A remote control operation is available through the RS 232C RS 485 port It displays the date and time the name of channel on the monitor as well as when it occurs any channel loss 1 2 Features e Supporting 4 of HD SDI and HDMI Inputs Selectable e Displaying in quad four HD SDI HDMI signals at real time e Auto sequence mode e Supporting Various output mode 1920x1080 1680x1050 1600x1200 1440x900 1280x1024 1360x768 1024x768 1280x720 e Displaying date time channel name and the current status OSD e RS 232C RS 485 commun
6. IN DEFAULT by pressing A V buttons gt Press lt q gt buttons to select the SDI HDMI 5 7 3 TITLE To revise the channel name Title Max 16 Characters CHANNEL SET gt Go to TITLE by pressing A V buttons gt Press 4 gt buttons to select the channel name using 63 characters 5 8 EVENT LIST EVENT LIST NO YY MM DD HH MM SS EVT CH 091 11 04 29 15 38 20 02 G01 11 24 29 17 00 30 A 3 001 11 05 03 12 08 40 EL 04 AYW MOVE J setect RR EXID HE 2 3 It shows the channel and the time when the event of ALARM LOSS were occurred L LOSS A ALARM 13 6 Connection Diagram HD SDI CAMERA IN x 4 lak hdd OUTPUT Serial Port Alarm IN OUT RS 232 RS 485 3 fone mar CETT ssc ame suman so uum rene LEE HDMI OUTPUT D SUB OUTPUT HD SDI HDMI input resolution supports only 1024x768p60 1280x720p 24 25 30 50 60Hz 1920x1080 50i 60i 24p 25p 30p 14 7 Warranty Certificate This product has passed thorough quality control and test and if this gets broken during normal use we provide 12 months warranty service Model No Serial No Distributor Date you purchased Place you purchased Warranty Period One 1 year from the date of purchase rurcnaser e Please check this warranty indication first e Please contact your distributor after checking out any defect in the products e The standard for repairing replacement or reimbursement follows Customer e Warranty cont
7. Released version 2 0 DIGITAL FULL HD QUAD SPLITTER SC HD04Q D User s Manual SC HD04Q D seeEyes Co Ltd C Precaution and Safety Guidelines Please read this user s manual thoroughly prior to use the unit for its easy and convenient use Do not install the product in the following places extremely low or high temperature conditions places exposed to rain snow or high humidity places containing or exposed to oil and gas places exposed to vibration and shock places under direct sunlight or exposed to outdoor weather conditions places exposed to radio waves RF or near to power lines It may cause low performance or malfunction of the unit e Do not disassemble the product or insert foreign objects The unit is subject to electric shock hazard Be careful not to get an electric shock while using the device Do not use and or connect any devices inappropriate to the unit It may cause malfunction of the unit or fire Use this product under temperature conditions only between O C and T509C Should use the DC 12V 1 5A adaptor certified for electromagnetic wave and for safety Should be careful not to have the lines changed when connecting them e Prior to turn on the device check the cable insulation condition of the data cable connected with external devices Before installing the product check its voltage rate and then turn on the power Make sure to turn off the product prior to installation
8. UT ON BUZZER TIME Q5 SEC LOSS ON EVENT SAVE ON EVENT CLEAR OFF DEFAULT ALL OFF Av MOVE Fatt eg RR ESTO A 5 3 1 SYSTEM ID When controlling SC HDOAQ RS 232 RS 485 at long short distance you can use the System Id You can insert from 1 to 255 SYSTEM SET Go to SYSTEM ID by pressing A V buttons Press gt buttons to change the set up value and select the number from 1 to 255 5 3 2 BAUDRATE When controlling SC HDOAQ RS 232 RS 485 at long short distance you can set the system communication speed Baudrate as 2400 4800 9600 14400 19200 28800 38400 SYSTEM SET Go to BAUDRATE by pressing A V buttons gt Press lt q gt buttons to select the baudrate 5 3 3 ALARM I O Alarm input and Alarm output selectable SYSTEM SET gt Go to ALARM I O by pressing A V gt Press 4 gt buttons to select ON OFF 5 3 4 ALARM HOLD To set the duration time of ALARM screen after the ALARM signal turns off SYSTEM SET gt Go to ALARM HOLD by pressing A V buttons gt Press b 4 buttons to set the time Second 1 99 sec 5 3 5 BUZZER OUT To set the Buzzer when button is used Alarm is detected and video signal loss is detected SYSTEM SET gt Go to BUZZER OUT by pressing A V buttons gt Press b 4 buttons to select ON OFF 5 3 6 BUZZER TIME To set buzzer duration time SYSTEM SET gt Go to BUZZER TIME by pressing A V buttons gt Press 4 gt buttons to set the
9. V 4 Y Press these buttons to adjust the menu selected Press these buttons to change the set value 3 1 2 SC HD04Q D Rear connection port D SDI in X 4 Connect with the 4 of HD SDI camera HDMI in X 4 Connect the 4 of HD SDI camera 8 Monitor SPOT Output Connect the SD standard definition Video Monitor NTSC PAL selectable for Monitor output format HDMI OUT Connect the HD High Definition Monitor with HDMI input port 5 Serial Port Connect the RS 232C to link external devices for remote control function e Data configuration Data Length 8 Bit Start Stop Bit 1Bit Parity Bit None Baud rate 9 600 bps Packet structure Control Communication Data format Byte UE TII Function 1 OxAO STK Launching Data 72 0x00 OxFF 0x16 Device Code SSS 73 0x00 OxFF Address Device ID a Data byte ConroData s check Sum Check Sum Byte2 Byte3 Byte4 mpm DATA Code Function Remarks 04 Full Display Control G Multiscreen 6 0x50 P Quad screen Display Display Control 7 Ox z AutoSequence 8 oxes d Down Menumove e oxc 1 te aol o2 r Rih gt 31 os u Up m Minus Set Value change 42 Ox6D 13 0x70 p Plus VGA OUT Connect the Monitor with the VGA input 4 SDI OUT Connect the HD High Definition Monitor with SDI input or Connect the other devices 1
10. ent any defect under normal use within the warranty service period we give you free repair service according to the warranty certificate We charge you with the fee of parts and service despite of free warranty service period Any breakage made without care such as Breakage or trouble made by natural disaster Breakage or trouble made by breaking the product guide or manual Breakage or trouble made by wrong power voltage or frequency When you want to reassemble for full system or replace parts within warranty service period When unauthorized person modified or made damage on the product trying to repair it e Please note that we don t support the breakage after warranty service period is expired If the customer wants to get it repaired we charge them with the fee e The specification is subject to change without prior notice for quality improvement US SeeEyes Co Ltd 503 507 Sunil Technopia 440 Sangdaewon Dong Jungwon Gu Sungnam Si Gyeonggi Do Korea TEL 82 0 31 777 3508 FAX 82 0 31 777 3512 EMAIL overseas sscctv com http www sscctv com eng 15
11. gt HDMI 11 5 5 5 SEQUENCE TIME To set display switching time by second 1 499 when selecting Auto Sequence mode SYSTEM SET gt Go to SEQUENCE TIME by pressing A V buttons gt Press 4 P buttons to set the time Second 1 99 sec 5 6 DATE TIME SET DATE TIME SET DATE FORMAT YY MM DD LOCATION LEFT DATE SET 11 66 23 TIME SET 15 30 30 AvV MOVE Ko seLeECT EXTD A 2 3 5 6 1 DATE FORMAT To set the date display format DISPLAY SET gt Go to DATE FORMAT by pressing A V buttons gt Press 4 gt buttons to set the FORMAT 5 6 2 LOCATION To set the location of the date and time DISPLAY SET gt Go to LOCATION by pressing A V buttons gt Press 4 gt buttons to set location of the date and time out of RIGHT CENTER LEFT 5 6 3 DATE SET To set the date DISPLAY SET gt Go to DATE SET by pressing A V buttons gt Press 4 gt buttons to set the date 5 6 4 TIME SET To set the time DISPLAY SET gt Go to TIME SET by pressing A V buttons gt Press b buttons to set the time 12 5 7 CHANNEL SET CHANNEL SET CHANNEL 01 IN DEFAULT SDT TITLE CHOT Av vOVE K SELECT ET A a 5 7 1 CHANNEL You can select the channel you want to set up CHANNEL SET gt Go to CHANNEL by pressing A V buttons gt Press 4 gt buttons to set the channel 5 7 2 IN DEFAULT When the SDI and HDMI are input together set the DISPLAY first CHANNEL SET gt Go to
12. ication port for external devices 1 3 Applications e Where a centralized supervisory and control system is needed such as the control center at Subway Airport Port and etc e At a control center of large buildings and express way and etc 2 Components Rack mount Power User s SC HD04Q D bracket Adapter Manual 3 Product Parts and Peripheral Device Connection 3 1 Name of Parts and Function 3 1 1 SC HD04Q D Front seelyes SO ccs m SDI S HOM DIGITAL QUAD D D POV Select ON OFF 2 CAMERA SELECT Press the channel number which you want to watch to display the video in full screen When receiving SDI HDMI signal simultaneously SDI and HDMI are selectable by pressing this button 3 AUTO SEQUENCE C3 In full single screen mode press this button to display the screen in auto sequence mode according to the dwell time adjusted in each channel Press it again to cancel the auto sequence mode You can set the auto screen dwell time of split screen in menu Sequence Time Please refer to menu 5 5 5 Sequence Time Sec Full Single screen mode MULTI SCREEN E Please press the multi screen button to select the Quad screen mode 5 ESC Press this button to cancel the menu configuration in Setup Menu mode 6 ENTER Press this button to select the menu you want in Setup Menu mode MENU Press this button to go to the Setup Menu mode and select the menu you want to adjust A
13. iming diagram External External Data IN Data IN External Data OFF Alarm INPUT ALARM HOLD TIME mode Screen Display Last Screen Display mode BUZZER TIME ON x Alarm Hold Time is delayed as the Buzzer Time does Alarm Hold Time Buzzer Time 8 4 How to put the Alarm in Use a contact point signal such as switches or relay to Open Short the Inx and the GND Alarm Input port Do not use any contact point with electrical signal It may cause any malfunction of the device 8 5 Alarm Output The Alarm output provides the connect point to activate a warning lamp or alarm bell when an alarm is entered 8 6 Alarm Output Contact Point The Alarm output contact point is under Normal Open relay of 1A 24VDC 0 5A 125 VAC The relay may not activate properly when an overrated power is applied in the alarm output contact point 8 7 Function The relay maintains closed when any external input is ON that is when the Alarm Input port is produced a short circuit The relay maintains open when any external data is off or the alarm input is off after the alarm time is ended jo SDI OUT 9 Port for upgrading Firmware Power Input X SC HDO4Q D DC 12V input model Rear side SDI OUT 4 Specification OSD On Screen Display External Interface 14p Power Consumption Case body Weight SC HD04Q D 1920x1080 24p 25p 30p 60i 1280x720p 24 25 30 50 60 1024x768p 60 1280x1024p 60 1
Download Pdf Manuals
Related Search
Related Contents
Targus 15.4" Trademark Toploading 300 Edition Notebook Case Installation Manual GL Blue Soul Top Manual English Manual - Amazon Web Services Capacitación Hoja de registro Cliente: Kintetsu World Express (KWE flow chart - MK Products 事業内容 - メディカル・エイド株式会社 installation procedure operation alarm information COINCO GLOBAL EURO MANUEL D`UTILISATION ET DE SERVICE Guía de referencia del usuario Copyright © All rights reserved.