1. contents OPERATING ENVIRONMENT Se RJ 11 RJ 11 Wy lt gt _ www apc com ne en a USB RJ 45 i Va 3 j j 32 104 F 0 40 C CE CE a g WA LY ov A L ly maf CONNECT INTERFACE CABLE CHECK BUILDING WIRING FAULT INDICATOR If the rear panel Building Wiring Fault red indicator is lit a potential shock hazard exists due to one of the following conditions Wall jutlet Open or high resistance ground connect PHONE MODEM FAX Phone Jack a For connection of APC s optional external 24 volt battery pack BR24BP to the Back UPS RS XS 1500 gt Printer or Scanner lt lt Hot or neutral polarity reversed TEN To Computer USB Overloaded neutral circuit Port a AN a SI F A Improper building wiring should be a USB RJ 45 Q corrected by a qualified electrician Do not lt A m E NX me TTT By et Mew Y
2. use the Back UPS until the condition that caused the fault is corrected Mo Note Improper building wiring will not prevent the Back UPS from operating but it will limit its protection capability Computer Modem Port m 7i EO External Disk or CD DVD Drive Computer nia AO CONNECT 10 100 Base T or VOIP SWITCH ON THE BACK UPS tiae O outlet C Back UPS RS models only aana 0 Note Allow the Back UPS to charge for a full e When Self Test has successfully completed Computer mee d gt Ol E lt Ma ioe E eight 8 hours prior to use only the green On Line indicator will be lit D N TA q A Network Jack Press the front panel Power ON OFF switch and e Ifthe internal battery cartridge is not 12A 60Hz 3 observe that the following events occur after connected see Step 2 above the green On eG o _ __ gt pressing and releasing the switch Line indicator and red Replace Battery us LISTED Modem Th ine indi flash indicators will light The Back UPS will also 95463 Phone Fax Computer The green On Line indicator flashes emit a chirping sound Network Port The yellow On Battery indicator lights while
3. to adjust the transfer voltage This is a simple task requiring use of the front panel pushbutton To adjust the transfer voltage proceed as follows Green On Line indicator is on and 1 Plug the Back UPS into the utility power source The Back UPS will be in a all other front panel indicators are Standby Mode no indicators lit aut flashing 2 Press the front panel pushbutton fully inward for 10 seconds All indicators on the Back UPS will flash to acknowledge going into Programming Mode 3 The Back UPS will then indicate its current Sensitivity Setting as shown in the Red Overload indicator is on or flashing Connected equipment is drawing more power than the Back UPS can provide Internal UPS fault Move one or more equipment power plugs from Battery Backup outlets to Surge Only outlets Contact APC Technical Support see Contact Information following table Indicators Sensitivity Input Voltage Input Voltage Use When Flashing Setting Range Range for utility for utility operation operation ORDER REPLACEMENT BATTERY CARTRIDGE E A E The battery cartridge typically lasts 3 6 years shorter if subjected to frequent outages or elevated temperatures Order part number RBC32 for 1000 VA 1 Low 78 150 Vac 78 142 Vac Input voltage is models or RBC33 for 1500 VA models yellow extremely low or high Not recommended for computer loads REPLACE
4. BATTERY CARTRIDGE 2 Medium 83 147 Vac 83 139 Vac Back UPS frequently yellow factory goes On Battery and red default 3 High 88 144 Vac 88 136 Vac Connected equipment is yellow sensitive to voltage z red and fluctuations s red i 4 To select the Low Sensitivity setting press the pushbutton until the yellow indicator is flashing Q yj 5 To select the Medium Sensitivity setting press the pushbutton until the yellow Si and red indicators second and third from the top are flashing To select the High Sensitivity setting press the pushbutton until yellow and both green indicator is flashing Once in Programming Mode if the pushbutton is not pressed within 5 seconds the Back UPS will exit Programming Mode all indicators will extinguish 6 red indicators bottom three are flashing 7 To exit without changing the Sensitivity Setting press the pushbutton until the 8 tf Batte Cartridge A 990 1162A Copyright 2004 American Power Conversion All rights reserved APC and Back UPS are registered trademarks of American Power Conversion All other trademarks are the property of their respective owners
5. D 10 100 Base T a Self Test is being performed Monitor yok INSTALL SOFTWARE ON COMPUTER CONNECT TVSS GROUND The Back UPS features a transient Replace Battery red is lit whenever the battery is near the end of its useful life or if the battery is not con nected see above A battery that is near the end of its use Overload red is lit whenever power demand has exceeded the capacity of the Back UPS There are four status indicators lights on the front panel of the Back UPS On Line On Battery Overload and Replace Battery On Battery yellow is lit whenever the battery of the Back UPS is powering equipment connected to the Battery Backup Outlets Follow the lt on screen instructions If Autoplay is not enabled on the computer proceed as follows 1 On the computer desktop of the display double click on My Computer 2 Double click on the CD ROM drive icon and follow the on screen instructions voltage surge suppression TVSS screw for connecting the ground lead on additional surge suppression devices such as network and data line surge protectors Wall Outlet From Data Line TVSS lt Dm Modem Phone Fax o i a Hs On Line e On Battery e Overload ee Replace Battery aa On Line green is lit whenever utility power is power
6. e Have the Back UPS model number serial number and date of purchase available Be prepared to troubleshoot the problem with an APC Technical Support representative If this is not successful APC will issue a Return Merchandise Authorization RMA number and a shipping address Typical Recharge Time 8 Hours Back UPS does not power Equipment plugged into a Surge Only outlet Unplug device from Surge Only outlet and move to a Battery Operating Temperature 32 to 104 F LIMITED WARRANTY essential equipment during an Backup outlet 0 0 outage 0 to 40 C The standard warranty is two 2 years from the date of purchase APC s standard Back UPS operates on battery Back UPS circuit breaker tripped Disconnect non essential equipment from the Back UPS Reset Storage Temperature 23 to 113 F procedure rf to replace me ongina a with a oe Magra tory unit Customers although utility power exists push in the rear panel circuit breaker Switch the Back UPS on 5 to 45 C MAO must have the origmal unde back auc T9 the assignment Of asset tagsrand se depreciation schedules must declare such a need at first contact with an APC Technical Support representative APC will ship the replacement unit once the defective unit has been received by the repair department or cross ship upon the receipt of a valid credit card number The customer pays for shipping the unit to APC APC pays ground freight transportation costs to ship the replacement unit to the c
7. er If the Back UPS requires service do not return it to the dealer The following steps should be taken default settings 88 139 Vac XS model 1 Consult the Troubleshooting section to eliminate common problems Back UPS circuit breaker tripped Disconnect non essential equipment from the Back UPS Reset i 2 Ifthe problem persists go to http www apc com support push in the rear panel circuit breaker Switch on the Back UPS Automatic Voltage Regulation AVR 112 OE 12 RS model 3 Ifthe problem still persists contact APC Technical Support and plug in devices one at a time If the circuit breaker trips again disconnect the device that caused the breaker to trip On line Frequency Range 47 63 Hz autosensing Utility input voltage quality is out of range Consider adjusting the transfer voltage and sensitivity See Transfer Voltage and Sensitivity Adjustment On battery Waveshape Stepped Sine Wave Maximum Load 1000 VA 600 W 1500 VA 865 W and plug equipment in one at a time If the circuit breaker trips again disconnect the device that caused the breaker to trip Operating Storage Relative Humidity 0 to 95 non condensing Utility input voltage quality is out of range Consider adjusting the transfer voltage and sensitivity See Transfer Voltage and Sensitivity Adjustment Size H x W x D 14 6 x 3 4 x 13 1 inch 37 1 x 8 6 x 33 3 cm
8. ing the Battery Backup outlets Four Beeps Every 30 Seconds this alarm is sounded whenever the Back UPS is running On N Battery Consider saving work in progress aN Continuous Beeping this alarm is sounded whenever a low battery condition is reached Battery run time is very low Promptly save any work in progress and exit all open applications Shutdown the operating system computer and N the Back UPS oe Continuous Tone this alarm is sounded whenever the Battery Backup outlets are overloaded Ot Circuit Breaker the circuit breaker button located on the rear panel of the Back UPS will stick out if an overload condition forces the Back UPS to disconnect itself from utility power If the button sticks out disconnect non essential equipment Reset the circuit breaker by pushing the button inward ful life has insufficient run time and should be replaced Z Chirps for 1 Minute Every 5 Hours this alarm is sounded whenever the battery has failed the automatic diagnostic test TROUBLESHOOTING Problem Back UPS will not switch on Possible Cause Back UPS not connected to AC power source Corrective Action Ensure the Back UPS is securely connected to an AC outlet SPECIFICATIONS Item On line Input Voltage Range Specification 88 147 Vac RS model SERVICE If the Back UPS arrived damaged notify the carri
9. ustomer Back UPS does not provide Back UPS is heavily loaded Unplug non essential equipment printers scanners etc from Weight 1000 VA 22 Ibs 10 kg expected backup time the Battery Backup outlets and plug into Surge Only outlets 1500 VA 25 lbs 11 kg CONTACT INFORMATION Back UPS battery cartridge is discharged due to Charge the battery cartridge for 8 hours Back UPS runtime is Shipping Weight 1000 VA 23 Ibs 10 kg 7 recent power outage and has not had time to reduced until the battery cartridge is fully charged 1500 VA 26 lbs 12 kg Technical Support http Awww apc com support recharge EMI Classification FCC DOC Class B Certified Alsueeemet http www ape com Battery has reached the end of its life Replace battery cartridge see Order Replacement Battery On Battery Run Time See http www apc com product USA Canada 1 800 800 4272 Candee Mexico 292 0253 292 0255 Red Replace Battery indicator is Internal battery cartridge is not connected Connect battery cartridge see Connect Battery Cartridge i flashing Green On Line indicator ass ee ana TRANSFER VOLTAGE AND SENSITIVITY ran O 1s On ADJUSTMENT oridwide i Red Replace Battery indicator is Battery has reached the end of its life Replace the battery cartridge see Order Replacement Battery on Cartridge In situations where the Back UPS or connected equipment appears too sensitive to input voltage it may be necessary