IB IL 24 DO 2-2A - Onlinecomponents.com

image

Contents

1. K W Where Puou Power dissipation of the housing Ta Ambient temperature Limitation of Simultaneity Derating Speed 500 kbps Ambient Temperature TA Maximum Load Current at 100 Maximum Load Current at 50 Simultaneity Simultaneity 55 C 1A 2A 40 C 2A 2A With an ambient operating temperature of 55 C and 100 simultaneity a load current of 1 A per channel is permissible If only one channel is used 50 simultaneity a load current of 2 A can be tapped With an ambient temperature of 40 C a maximum load current of 2 0 A can be tapped in both cases If both channels are used the permissible working point must be defined according to the above formulas For an example please refer to the IB IL SYS PRO UM E user manual or the Inline system manual for your bus system 5556_en_03 PHOENIX CONTACT 4 THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS IB IL 24 DO 2 2A Limitation of Simultaneity Derating Speed 2 Mbps Ambient Temperature TA Maximum Load Current at 100 Maximum Load Current at 50 Simultaneity Simultaneity 55 C 0 7 A 1 2 A 35C 2A 2A With an ambient operating temperature of 55 C and 100 simultaneity a load current of 0 7 A per channel is permissible If only one channel is used 50 simultaneity a load current of 2 A can be tapped With an ambient temperature of 35 C a maximum load current of 2 0 A can be tapped in both cases If both channels are used the permissible working point must be defined accordin
2. 2 4 Other Bus Systems For the programming data configuration data of other bus systems please refer to the corresponding electronic device data sheet GSD EDS PHOENIX CONTACT 09 2007 For the assignment of the illustrated byte bit view to your INTERBUS control or computer system please refer to the DB GB IBS SYS ADDRESS data sheet a 5556 en 03 PHOENIX CONTACT GmbH amp Co KG 32823 Blomberg Germany 9 as Phone 49 0 5235 3 00 Fax 49 52 35 34 12 00 www phoenixcontact com
3. THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS IB IL 24 DO 2 2A Inline Terminal With Two Digital Outputs AUTOMATIONWORX Data Sheet 5956 _ en 03 PHOENIX CONTACT 09 2007 Description The terminal is designed for use within an Inline station It is used to output digital signals Features Connections for two digital actuators Connection of actuators in 2 3 and 4 wire technology Nominal current per output 2 A Total current of the terminal 4 A Short circuit and overload protected outputs Diagnostic and status indicators Approved for the use in potentially explosive areas observe the notes on page 7 IB IL 24 DO 2 2A and IB IL 24 DO 2 2A PAC Approved for use within a safety related segment circuit observe the notes on page 6 This data sheet is only valid in association with the IL SYS INST UM E user manual or the Inline system manual for your bus system Make sure you always use the latest documentation It can be downloaded at www download phoenixcontact com A conversion table is available on the Internet at www download phoenixcontact com general 7000 en OO pdf IR This data sheet is valid for the products listed on the following page DOG 0OC DMO0Meleo gt Lionna 0D E INSPIRING INNOVATIONS Ordering Data Products Description Terminal with two digital outputs complete with accessories connector and labeling field transmission speed o
4. The Inline terminal must not be repaired by the user WARNING Explosion hazard Before startup ensure that the following points and instructions are observed WARNING Explosion hazard Only Inline terminals that are approved for use in potentially explosive areas may be snapped next to this Inline terminal Before using an Inline terminal in a zone 2 potentially explosive area check that the terminal has been approved for installation in this area For a list of terminals approved for zone 2 potentially explosive areas please refer to the AH EN IL EX ZONE 2 application note Check the labeling on the Inline terminal and the packaging see Figure 3 Repairs may only be carried out by the manufacturer The Inline terminal is to be replaced by an approved terminal of the same type Only category 3G equipment may be connected to Inline terminals in zone 2 7 Observe all applicable standards and national safety and accident prevention regulations for installing and mover operating equipment Graer Ne 00 HW FW XX Restrictions PHENIX Proc Ctrl For Haz Locs PER MIO SE Sar RE sercon WARNING Explosion hazard When using terminals in potentially explosive areas observe the technical data and limit values specified in the corresponding documentation user manual data sheet package slip Figure 3 Typical labeling of terminals for use in potentially explosive areas WARNING Explosion hazard Restri
5. ctions regarding the Inline system The maximum permissible current flowing through the potential jumpers Up and Us total current is limited to 4 A when using the Inline terminal in potentially explosive areas 5556_en_03 PHOENIX CONTACT 7 onlinecomponents com THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS IB IL 24 DO 2 2A Internal Circuit Diagram Connection Example When connecting the actuators observe the assignment of the terminal points to the process data see page 9 INTERBUS ppe _ a H Jor 24 V Ug 7 s 24 V Un au i 7 5556A003 Figure 4 Internal wiring of the terminal points 5556A004 Figure 5 Typical actuator connection Key Protocol chip A 4 wire termination bus logic including voltage conditioning B 3 wire termination LED Optocoupler Transistor Digital output Electrically isolated area Other symbols used are explained in the IB IL SYS PRO UM E user manual or the system manual for your bus system 5556_en_03 PHOENIX CONTACT 8 Programming Data Configuration Data Local Bus INTERBUS Output address area 2 bits Parameter channel PCP O bits THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS IB IL 24 DO 2 2A Process Data Assignment of the OUT Process Data Byte bit view Module Terminal point signal Terminal point 24 V 2 2 Terminal point GND Terminal point FE
6. f 500 kbps Terminal with two digital outputs without accessories transmission speed of 500 kbps Terminal with two digital outputs complete with accessories connector and labeling field transmission speed of 2 Mbps Terminal with two digital outputs without accessories transmission speed of 2 Mbps THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS IB IL 24 DO 2 2A Type Order No IB IL 24 DO 2 2A PAC 2861263 IB IL 24 DO 2 2A 2726243 IB IL 24 DO 2 2A 2MBD PAC 2861700 IB IL 24 DO 2 2A 2MBD 2861700 Pcs Pkt 1 IR One of the listed connectors is needed for the complete fitting of the IB IL 24 DO 2 2A and IB IL 24 DO 2 2A 2MBD terminals Accessories Description Connector with eight spring cage connections green w o color print Connector with eight spring cage connections green with color print Documentation Description Configuring and Installing the INTERBUS Inline Product Range user manual Automation Terminals of the Inline Product Range user manual INTERBUS Addressing data sheet Inline Terminals for Use in Zone 2 Potentially Explosive Areas application note Safety Related Segment Circuit application note Technical Data General Data Housing dimensions width x height x depth Weight Operating mode Connection method for actuators Permissible temperature operation Permissible temperature storage transport Permissible humidity operation storage transport Permissible air pres
7. g to the above formulas For an example please refer to the IB IL SYS PRO UM E user manual or the Inline system manual for your bus system Safety Equipment Overload short circuit in segment circuit Electronic Surge voltage Protective elements in the power terminal Polarity reversal Protective elements in the power terminal Electrical lsolation Isolation of the Voltage Areas To provide electrical isolation between the logic level and the I O area it is necessary to supply the station bus coupler and the digital output terminal described here via the bus coupler or a power terminal from separate power supply units Interconnection of the power supply units in the 24 V area is not permitted See also user manual Common Potentials The 24 V main voltage 24 V segment voltage and GND have the same potential FE is a separate potential area Separate Potentials in the System Consisting of Bus Terminal Module Power Terminal and I O Terminal Test Distance Test Voltage 5 V supply incoming remote bus 7 5 V supply bus logic 500 V AC 50 Hz 1 min 5 V supply outgoing remote bus 7 5 V supply bus logic 500 V AC 50 Hz 1 min 7 5 V supply bus logic 24 V supply I O 500 V AC 50 Hz 1 min 24 V supply I O functional earth ground 500 V AC 50 Hz 1 min Error Messages to the Higher Level Control or Computer System Short circuit overload of an output Yes An error message is generated when an output is shorted and switched on In addi
8. pulses Protected against reverse voltages Resistance to permanently applied reverse voltages Up to 2 A DC Validity of output data after connecting the 24 V supply voltage power up 5 ms typical Response upon power down The output follows the supply voltage without delay 5556_en_03 PHOENIX CONTACT 3 THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS IB IL 24 DO 2 2A Digital Outputs Continued Limitation of the voltage induced on circuit interruption 0 7 V approximately Maximum inductive breaking energy channel 1500 W 8 20 us pulse Type of external protective circuit Free wheeling diode per channel Output Characteristic Curve When Switched On Typical Output Current A Differential Output Voltage V 500 kbps 2 Mbps 0 0 0 0 2 0 02 0 013 0 4 0 04 0 026 0 6 0 06 0 039 0 8 0 08 0 053 1 0 0 10 0 066 1 2 0 12 0 079 1 4 0 14 0 093 1 6 0 16 0 107 1 8 0 18 0 122 20 0 20 0 136 2 2 0 22 Power Dissipation Formulas to Calculate the Power Dissipation of the Electronics 500 kbps 2 Mbps 2 2 Pam OE W 2 PU mN h xO TO P 040W 35 mW 1 2 x 0 075 Q ae Where PEL Total power dissipation in the terminal n Index of the number of set outputs n 1 to 2 IL Load current of the output n Power Dissipation of the Housing Depending on the Ambient Temperature 500 kbps 2 Mbps Phou 2 4 W 25 C lt T lt 5 C 0 6 W within the permissible operating temperature T 5 C Piou 2 4 W a 5 C lt T lt 55 C 37 5
9. rcuit is not adversely affected Status indicators of the outputs The latest documentation can be downloaded at www download phoenixcontact com Function Identification Pink 2MBD White stripe in the vicinity of the D LED Terminal Point Assignment Terminal points Assignment Signal output OUT Segment voltage Us for 4 wire termination Measuring point for the supply voltage Ground contact GND for 2 3 and 4 wire termination FE connection for 3 and 4 wire termination 5556_en_03 PHOENIX CONTACT 6 onlinecomponents com THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS IB IL 24 DO 2 2A Notes on Using the Terminal in Potentially Explosive Areas Approval According to EC Directive 94 9 ATEX x II 3G Ex nAC IIC T4 X This Inline terminal conforms to the requirements of protection type n and can be installed in a zone 2 potentially explosive area This Inline terminal is a category 3G item of electrical equipment 1 When working on the Inline terminal always disconnect the supply voltage 2 The Inline terminal must only be installed started up and maintained by qualified specialist personnel 3 Install the Inline terminals in a control cabinet or metal housing The minimum requirement for both items is IP54 protection according to EN 60529 4 The Inline terminal must not be subject to mechanical strain or thermal loads which exceed the limits specified in the product documentation 5
10. sure operation storage transport Degree of protection Class of protection Connection data for connectors Connection type Conductor cross section Interface Local bus 5556_en_03 Type Order No Pcs Pkt IB IL SCN 8 2726337 10 IB IL SCN 8 CP 2727608 10 Type Order No Pcs Pkt IB ILSYS PRO UME 2743048 1 IL SYS INST UME 2698737 1 DB GB IBS SYS ADDRESS 9000990 1 AH EN IL EX ZONE 2 Woda 1 AH EN IL SAFE 7195 1 12 2 mm x 120 mm x 71 5 mm 46 g without connector 61 g with connector Process data mode with 2 bits 2 3 and 4 wire technology 25 C to 55 C 25 C to 85 C 10 to 95 according to DIN EN 61131 2 70 kPa to 106 kPa up to 3000 m above sea level IP20 according to IEC 60529 Class 3 according to EN 61131 2 IEC 61131 2 Spring cage terminals 0 2 mm to 1 5 mm solid or stranded 24 16 AWG Through data routing PHOENIX CONTACT 2 Transmission Speed IB IL 24 DO 2 2A PAC IB IL 24 DO 2 2A IB IL 24 DO 2 2A 2MBD PAC IB IL 24 DO 2 2A 2MBD 500 kbps 2 Mbps Supply of the Module Electronics and I O Through Bus Terminal Power Terminal Connection method Via potential routing THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS IB IL 24 DO 2 2A Power Consumption 500 kbps 2 Mbps Communications power 7 5V 7 5V Current consumption from the local bus 35 mA maximum 60 mA maximum Power consumption from the local bus 0 27 W maximum 0 45 W maximum Segment supply voltage Us 24 V DC nominal
11. tion the diagnostic LED D flashes on the terminal at 2 Hz medium under these conditions Falling below or exceeding the operating voltage No Approvals For the latest approvals please visit www download phoenixcontact com or www eshop phoenixcontact com 5556_en_03 PHOENIX CONTACT 5 onlinecomponents com THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS IB IL 24 DO 2 2A Local Diagnostic and Status Indicators Notes on Using the Terminals Within a and Terminal Point Assignment Safety Segment Circuit The terminals of the following hardware version and later listed in the table below are approved for use within a safety related segment circuit Order No Order Designation Hardware Version 2726243 IB IL 24 DO 2 2A 2861263 B IL 24 DO 2 2A PAC The hardware version is marked on the side of the housing of every terminal 1 in Figure 2 a il a ca N is Wy 2 2 1 3 g D D 3 odule ID HW SW YO Bee N lt 7 N iN IRIS f SL E 5556A008 Figure 2 Labeling on an Inline terminal 5556C002 Figure 1 IB IL 24 DO 2 2A with the appropriate The instructions in the current documentation connector for the safety terminal and from the AH EN IL SAFE application note must be observed to ensure that operation of the Local Diagnostic and Status Indicators Color Meaning safety related segment ci
12. value 24 V DC nominal value Nominal current consumption at Us 4A 2 x 2 A maximum 4A 2x2 A maximum Digital Outputs Number 2 Nominal output voltage Ugyt 24V DC Differential voltage for lhom lt 1V Nominal current lhom per channel 2A Tolerance of the nominal current 10 Total current 4A Protection Short circuit overload Nominal load Ohmic 12 9 48 W Lamp 48 W Inductive 48 VA 1 2 H 50 Q Signal delay upon power up of Nominal ohmic load 200 us approximately Nominal lamp load 200 ms typical with switching frequencies up to 8 Hz above this frequency the lamp load responds like an ohmic load Nominal inductive load 250 ms 1 2 H 12 Q approximately Signal delay upon power down of Nominal ohmic load 200 us approximately Nominal lamp load 200 us approximately Nominal inductive load 250 ms 1 2 H 12 Q approximately Switching frequency with Nominal ohmic load 300 Hz maximum This switching frequency is limited by the selected data rate the number of bus devices the bus structure the software and the control or computer system used a Nominal lamp load 300 Hz maximum This switching frequency is limited by the selected data rate the number of bus devices the bus structure the software and the control or computer system used Nominal inductive load 0 5 Hz 1 2 H 12 maximum Overload response Auto restart Response with inductive overload Output may be damaged Reverse voltage protection against short

Download Pdf Manuals

image

Related Search

Related Contents

WIRE DOG CRATE - Miller Manufacturing  FC-7564 user manual - e  Samsung SGH-B520V Benutzerhandbuch  X-CM52BT-K/-W  L-3 Guardian® was develope - L  Philips Daily Collection Coffee maker HD7451/00  I - MANUALE DI ISTRUZIONI PER TORCE PLASMA  Les Infos Communales N° 33 R A V E N E L  データ復旧サービス(診断) - データ復旧サービスセンター金沢  Instrucciones de servicio  