Home
MS-5400
Contents
1. L X 800 W X 600 H mm Key Functions ON OFF UNIT HOLD BMI TARE 7 2V 1200mA rechargeable battery pack AC adapter 15V 300mA Power Supply Operation Temperature gt PC LCD SYMBOL DESCRIPTION Hold Indication NET WEIGHT Indication BMI Indication WEIGHT Indication Above LCD symbol definitions are explained in Page 8 Key Functions Definitions Stable symbol When user stands on scale and is stable Minus weight Weight under zero Zero symbol Weight is at zero point Low battery Voltage is too low to operate Stable symbol Minus weight Zero symbol Low Battery KEY FUNCTIONS gmi HOLD NET WEIGHT ON UNIT HOLD OFF BMI age chorder Description gt ON OFF Press to power on and power off gt UNIT Press to select weight unit kg Ib gt HOLD BMI Press to lock weight during weighing Press again to release Keeping press HOLD BMI key for 3 seconds to enable BMI function BMI operation please refer to page 11 gt TARE Press to tare the weight of target POWER SUPPLY gt The CHR691 uses rechargeable battery pack or AC adaptor gt When the indicator displays _ lg low battery indication please plug in the AC adaptor for operations and recharge USING YOUR HOLD FUNCTION Oo Sl en Press ON OFF to turn on the scale Let the patient onto the scale after LCD shows 0 0 and stable symbol Press HOLD BMI key to lock the weight that given by the dev
2. ble for damages arising out of failure to heed the following instructions When using electrical components under increased safety requirements always comply with the appropriate regulations Improper installation will render the warranty null and void Ensure the voltage marked on the power supply unit matches your mains power supply This device is designed for use indoors Observe the permissible ambient temperatures for use The device meets the requirements for electromagnetic compatibility Do not exceed the maximum values specified in the applicable standards Ensure that the patient does not lean against the device risk of falling If you have any problem contact your local CHARDER MEDICAL service partner ENVIROMENTAL All batteries contain toxic compounds disposal of batteries should be delegated to a competent organization complying with the deposit of Poisonous Waste Regulation 1972 Please do not incinerate batteries The optimum operating temperature for the scale is 5C to 35C although it will operate at higher and lower temperatures the scales battery life will be adversely effected You are legally obliged to hand in used batteries rechargeable batteries to a local collection point so that they can be disposed of in an environmentally friendly way When buying new batteries select batteries low in harmful substances and no mercury Hg cadmium Cd or lead Pb CLEANING We would r
3. chorder MS 5400 USER MANUAL TABLE OF CONTENTS PREFACE aro TEE 2 GENERAL INFORMATION 222024244400404snnnennnnnnennne nennen nennen 2 SAFETY INSIRUCTION EB aia 2 ENVIROMENTA aora 3 BEEANIN Sans ee ina sos 3 MAINTENANGE sun ee en 3 WEIGRAING ORERATIONABBH RR 3 WARRANDTSLIABILI cacao 4 DISPOSAL erke 5 SPECIFICATION KG SEE RR 6 LCD SYMBOL DESCRIPTION siii 7 Pe TINS nee ee 8 USING YOUR HOLD FUNCTION 2222244002244nn anne nnnnnn nenn 9 INSTRUCTION FOR BMI FEATURE 2444442 nennen 9 INSTRUCTION FOR CHARGE AND CONNECT en 10 INSTRUCTION FOR REPLACING BATTERY use 11 ERROR MESSAGE ae nannten 12 PREFACE Thank you for choosing CHARDER MEDICAL product All features of this product were designed to state of the art and are optimized for simple and straightforward use If you have any queries or experience any problems not addressed in the operating instructions please contact your CHARDER MEDICAL service partner or visit us on the Internet at www chardermedical com GENERAL INFORMATION We strongly recommend you use the scales on flat and hard surface Any soft surface like carpet will cause inaccuracy SAFETY INSTRUCTION Before putting the device into use please read with care the information given in the Operating Instructions They contain important instructions for installation proper use and maintenance of the device The manufacturer shall not be lia
4. ecommend using alcohol based wipes or similar when cleaning the scales Please do not use large amounts of water when cleaning the scales as this will cause damage to the scales electronics you should also refrain from using corrosive liquids or high pressure washers Always disconnect the scales from the mains power supply before cleaning MAINTENANCE The scale does not require any routine maintenance However we recommend checking the scale s accuracy at regular intervals The regularity of these checks is dependent on the level of use and the state of the scale If any inaccuracies occur please contact your local dealer or CHARDER MEDICAL service partner WEIGHING OPERATION Before reading detailed instructions on how to use all the weighing functions that are built into your scale please read the following important guidelines Always be sure that the display shows Zero before use if it does not then please press the ZERO key The Professional Medical Hoist scale is designed to detect when a stable weight is achieved your reading should be taken at this point WARRANTY LIABILITY If a fault or defect is present on receipt of the unit which is within CHARDER MEDICAL s scope of responsibility CHARDER shall have the right to either repair the fault or supply a replacement unit Replaced parts shall be the property of CHARDER Should the fault repairs or replacement delivery not be successful the statutory provisions
5. ice Let the patient off the scale Check the weight value which being locked Press HOLD BMI to release the function Press ON OFF to end your measuring procedure Only pressing the HOLD button shall perform disabling and enabling the weighing lock function INSTRUCTION FOR BMI FEATURE Power on the device You will need to know the height of the person being weighed so it s the best to measure somebody s height before starting the weighing procedure Proceed to weigh as normal after the weight is stable press HOLD BMI key for 3 seconds to enter into BMI mode The display will then change to a display of height The person being measured can now get off the scale as the scale has memorized his her weight Then the operator starts to enter the height of person the height should be measured by centimeters Press TARE to change your height Press HOLD BM to move to next digit When the right figure sets for the height display in centimeters press UNIT to finish setting The display will then show the B M I reading Press UNIT key again to exit the B M I mode INSTRUCTION FOR CHARGE AND CONNECT If le Lo is displayed on the LCD you should charge scale with exclusive adaptor for MS 5400 Locate adaptor plug at the rear of indicator CAUTION Always connect the AC adaptor to the indicator before connecting to the mains power supply Please disconnect the adaptor from main power suppl
6. shall be valid The period of warranty shall be two years beginning on the date of purchase Please retain your receipt as proof of purchase Should your scale require servicing please contact your dealer or CHARDER MEDICAL Customer Service No responsibility shall be accepted for damage caused through any of the following reasons Unsuitable or improper storage or use incorrect installation or commissioning by the owner or third parties natural wear changes or modifications incorrect or negligent handling overuse chemical electrochemical or electrical interference or humidity unless this is attributable to negligence on the part of CHARDER MEDICAL If operating climatic or any other influences lead to a major change in conditions or material quality the treaty for perfect unit functioning shall be rendered null and void If CHARDER provides and individual warranty this means that the unit supplied will be free of faults for the length of the warranty period DISPOSAL This product is not to be treated as regular household waste but should be handed in to an electrical electronic equipment recycling centre You can obtain further details from your local council your municipal waste disposal company or the firm which you purchased the product SPECIFICATION MS 5400 Capacity 200kg x 100g 250kg x 100g 300kg x 100g Weight Unit Kg Lb selection LCD Display 1 0 inch LCD display with 5 and 1 2 digits Dimension 1100
7. y before indicator INSTRUCTION FOR REPLACING BATTERY 3 Replacing new batteries 4 Make sure batteries are well installed amp a gt 5 Reinstalling the battery housing 6 Reinstalling the battery cover 11 ERROR MESSAGE Low battery This warning shows that the voltage of battery is too low to use Please replace new battries or plug the AC adaptor for operation Counting error too low The loading is lower than limit when power on please increase the loading Fr r I and try again Ifthe trouble still exists please call your local service partner Overload or counting error too high please reduce the loading and try again If the trouble still exists please call your local service partner The loading is over limit when power on F E EEPROM Error The program of the scale has error please call your local service partner f r 13 14 Manufacturer s Declaration of Conformity This product has been manufactured in accordance with the harmonized European standards following the provisions of the below stated directives Electro Magnetic Compatibility Directive 93 42 EEC Low Voltage Directive 2006 95 EC FCC CLASS B Declaration of Conformity This device complies with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules IN XXXX XXXX 15
Download Pdf Manuals
Related Search
MS 5400 ms 53003 ms 52000-2 ms 52000-10 ms 5000 watts ms 45001 ms 50002 steel specifications ms 5000 ms5300 ms5300r ms 5000u mes5400-24 ms 50003 ms 5000x ms 5000 watts divorce
Related Contents
VPULSE Users Manual PDS 660 100V Pendant Ball Loudspeaker Présentation du nouveau code du travail Progress Lighting P3210-80WB Installation Guide RRSSSII microAlt 4600/9200 User`s Manual Copyright © All rights reserved.
Failed to retrieve file