WIZ220IO Datasheet

image

Contents

1. N N 20 5 WIZ220IO SpecificatioNi serie sesse geeis ges bes ge edge ed ee eks Sed be sis e ie sege gek GR ge beg ee Dee dee 22 LAAN as Na IE eie eee 22 DP PI THORP EA RE EN 22 Bide PIA EEE 22 54 Board Dimensions and Pin Assignment 23 EE AT SR n EE EE EE vesessne 24 Wiznet WIZ22010 User Manual V1 1 Table 1 Table 2 Table 3 Table 4 Table 5 Table 6 Table 7 Table 8 Table 9 Tables WIZ2201O SPECHICALON swiss suns inenen Enoe n EEEE O EEEE EEES 7 WIZ22010 Base Board Specification sesse see see see see ee ee ee Re ee ee ee ee ee 7 Frame format of notification sending parameters cce ecce e e e e e e e e e e e e e e e e e e e e ee se ee 19 Sending parameter description in the notification function sees eee ee ee e e e e e e e e e e 19 Frame format of notification receiving parameterS sesse e e e ee se e e se e e e e e e e e e e se ee 20 Receiving parameter description in the notification function sss e e e eee e e e e e enone 20 Electrical Characteristics a anr sesse esse ese E 9 REG RR PR RAAR KG PR RAAR RA RR GR RR AR RSA RR GR ee 22 RJ 45 Pin Assignment ss sessies sers EERS RE gesa vea gy ea a yeaa yeaa yea y eaa ER RE Y raa ESE ER SEER SEN 22 WIZ220IO DIMENSION i s ER Es og ER ed Re OE EE EE oe ER He SE eg ES od ER eed 23 Wiznet WIZ22010 User Manual V1 1 Figures Figure 1 Block Diagram Figure 2 WIZ220I0 Base Board Layout Figure 3 WIZ2201O Module Interface Figure
2. digital input value It can be set to H 0x48 or L 0x4C as input port status H or U digital output value It can be set to H 0x48 or L 0x4C as output port status ALO 2 erable analog input WO T mon f2 variable analog output 1 The ange of value Saans fend car a owt end char ofnticaton sending parameter Table 4 Sending parameter description in the notification function Total data size 45 bytes ID MAC IP and End char fields are fixed The transmitted digital value in Firmware v1 0 is different from above Table 4 The value will be 0x00 when the port in low voltage level as well the value 0x01 indicates the port is in high voltage level 19 WiZnet 4 2 Receiving Protocol Data transmission and the output port can be controlled via notification port Please note this WIZ22010 User Manual V1 1 function is only available in Firmware v1 1 or later 0 I 2 3 n 5 6 7 8 9 A B C D E F 0x00 ID OPIO opi OPRI OPI3 IP Dojo DONI 0x10 DORI DOBI DOM DOST DO DOM AO 0 AO 0x20 UART 0x30 Toa a Eed Table 5 Frame format of notification receiving parameters daa WIZ220 module s ID Fixed value as WIZ220 Hex 57 49 5A 32 32 O or not vna control select flag O Ox4F means user would like to control specified port if OP field is not O the module does not change specifi
3. does not cover such damage O S O Figure 6 Power adapter polarity 10 WiZnet WIZ22010 User Manual V1 1 Power Switch It controls power of WIZ220I0 module and base board Factory Reset button Factory reset button can recover configuration parameter to factory default values To reset the module s parameters to factory default hold down the factory reset button when you turn power switch on Variable Resistor VR You can control analog input value with variable resistor The WIZ220IO s analog input is voltage type and its range is OV to Vcc 5V Also its value was translated to 0 4095 as each input port has 12 bit resolution 5V_input VR1 VR R1 EE NN ALO 200 OD GNDAA 5V input VR2 vR R2 2 KA Al 200 ap EE DAA Figure 7 Variable Resistor Circuit of the WIZ22010 Base Board Analog Output Through Hole It can be connected to external device by user application Each port outputs its value as voltage level and the range of output voltage is 0 4V The maximum output value is 4095 that generates 4V level The hole pitch is 2 54mm 11 WizZnet 3 Configuration Tool WIZ22010 User Manual V1 1 The configuration tool supports below major functions All functions of configuration tool can be performed remote area through the Ethernet Change module s configuration O monitoring and controlling Firmware uploading Webpage uploading 3 1 Basic descri
4. module on the base board Incorrect mounting can damage the WIZ220I0 module and base board and your product warranty does not cover such damage J1 J2 CON20A 2 54mm CON20A 2 54mm w Digital I O Power Analog GNDAA Figure 3 WIZ220I0 Module Interface 9 Wiznet WIZ22010 User Manual V1 1 LED 8 LEDs are indicating each Digital Output ports When the port signal is LOW the LED light is turned on 3 3V 3 3V 3 3V 3 3V 3 6 3 3V 9 C 9 K N N NI NI N LED2 LED3 LED4 LED5 LED6 LED7 LED8 LED9 LEDG SMD LEDG SMD Vv LEDG SMD LEDG SMD oe SMD ae SMD EE LEDG SMD C S S S R8 5 R9 R10 R11 R12 0 R14 R15 200 E 200 200 200 200 200 200 a DO_O DO 1 DO 2 DO 3 DO 4 DO 6 DO 7 Figure 4 LED circuit of WIZ220I0 Base Board Switch 8 switches are controlling each Digital Input ports When you turn switch on the digital port signal will be LOW SW3 DI_O DI T DIL DI 3 DI d DI 5 DI_6 DI 7 SW DIP 8 Figure 5 DI Switch of the WIZ22010 Base Board D SUB9 This connector is for an UART The WIZ220IO s UART port can be used for debug message or data output through the webpage It supports RTS CTS flow control Power The power can be controlled by using power switch after connecting the DC 5V min 500mA adapter Caution Observe polarity and voltage when connecting the power adapter Incorrect input polarity or voltage can damage the WIZ220IO module and base board and your product warranty
5. monitoring and configuration Supports 10 100Mbps Ethernet 8 Digital Input Ports 8 Digital Output ports 2 Analog Input Ports with 12 bit resolution Voltage Type 2 Analog Output Ports with 12 bit resolution Voltage Type 1 UART Output Port Data acquisition and transmitting to specified host RoHS Compliant w IZnet WIZ22010 User Manual V1 1 1 2 Specification MCU Standard 8051 compatible in W7100 Architecture PHY Included in W7100 TCP IP Stack Hardwired TCP IP Stack in W7100 Network Protocols ARP ICMP TCP IP UDP HTTP Server DHCP Network Network Interface RJ 45 Auto MDIX Auto Negotiation Input CMOS Digital Input Output CMOS Digital Output 1 UART output Digital Baud rate 1200bps 230400bps Data bit 7bit 8bit UART i Parity none odd even Stop bit 1bit Flow control none RTS CTS Input 12bit resolution Input Range 0 Vcc Analog Output 12bit resolution Output Range 0 4v Input Voltage DC 5V Power Power Consumption Under 280mA 5V Environment Temperature 0 C 70 C Operation 40 C 85 C Storage Humidity 10 90 Table 1 WIZ22010 Specification Power Socket Inner pin 2 0 DC Power Jack Voltage DC 5V Digital Ports Input 8 Switch Output 8 LED Green chip LED UART D SUB 9PIN MALE Analog Input 2 Variable Resistor 10K ohm Output None Through Hole VO Switch Factory Reset Swit
6. 4 LED circuit of WIZ220I0 Base Board Figure 5 DI Switch of the WIZ220I0 Base Board Figure 6 Power adapter polarity Figure 7 Variable Resistor Circuit of the WIZ22010 Base Board Figure 8 Configuration Tool Figure 9 Network Tab of the Configuration Tool Figure 10 Serial Tab of the Configuration Tool Figure 11 Input Output Tab of the Configuration Tool Figure 12 Firmware uploading window Figure 13 Complete firmware uploading window Figure 14 RJ 45 PIN Assignment Figure 15 WIZ220I0 Module Dimension 10 10 10 11 12 14 15 16 17 17 22 23 Wiznet 1 Introduction WIZ22010 User Manual V1 1 WIZ220I0 is an embedded remote I O module which is able to control and monitor VO port remotely via Internet It is possible to monitor and control I O port by using Windows application program or the embedded Web server There are 16 digital VO ports and 4 analog I O supported by WIZ220I0 Additionally the firmware and embedded webpage can also be updated remotely through the Ethernet WIZ220I0 EVB is the evaluation base board for users to evaluate WIZ22010 module quickly There are 8 switches used for digital input test and 8 LEDs for digital output test and a variable register for analog input test included in this evaluation board 1 1 Main Function Operates as HTTP Server using W7100 all in one embedded network MCU with hardwired TCP IP stack Provides Configuration Tool Program for easy control
7. This offer is non transferable WiIZnet warrants our products and its parts against defects in materials and workmanship under normal use for period of standard ONE 1 YEAR for the WIZ220I0 module and labor warranty after the date of original retail purchase During this period WiZnet will repair or replace a defective products or part free of charge Warranty Conditions The warranty applies only to products distributed by WIZnet or our official distributors 1 The warranty applies only to defects in material or workmanship as mentioned above in 7 Warranty 2 The warranty applies only to defects which occur during normal use and does not extend to damage to products or parts which results from alternation repair modification faulty installation or service by anyone other than someone authorized by WlZnet damage to products or parts caused by accident abuse or misuse poor maintenance mishandling misapplication or used in violation of instructions furnished by us damage occurring in shipment or any damage caused by an act of God such as lightening or line surge Procedure for Obtaining Warranty Service 1 Contact an authorized distributors or dealer of WlZnet for obtaining an RMA Return Merchandise Authorization request form within the applicable warranty period 2 Send the products to the distributors or dealers together with the completed RMA request form All products returned for warranty must be carefully repackaged in th
8. WIZ22010 WIZ220I0 EVB Users Manual ver 1 1 2010 WIZnet Co Ltd All Rights Reserved For more information visit our website at www wiznet co kr WiZnet Document History Information WIZ22010 User Manual V1 1 Revision Data Description Ver 1 0 2010 04 Release with WIZ220I0 launching Added description of notification option as updating firmware The firmware ver 1 1 supports output control through the notification port The firmware ver 1 0 supports only transmission VO status modified description of configuration tool The transmitting period unit of notification option is changed from 1sec to 10ms as updating firmware Update VO States button in Input Output tab supports auto clicking with time period Ver 1 1 2010 06 Wiznet WIZ22010 User Manual V1 1 Table of Contents ME ele ie io EE N N EE N EE EG N N tiie 6 di Mel EUREUOR SR RE RE ee EE EE EE TE 6 L2 SPEI T 7 23 BIOCK MIJA TT 8 2 WIZ22010 Base Board DT 9 3 Configuration TOO oiana Rek ese is 12 31 BASIC description seene 12 44 INCL OII TOO EE EE RE EE EE EE ES EE A EE N ee 13 BiB YET N EE N N EE EE ES ON 15 24 mnput Outout TaD Ek RA ee ee AER R 16 FRONT IN GET 16 36 Webpage Upload EE ERRER 17 4 Notification Data Protocol ccscecescessesasecssccssssnsedensosanseseceussnsnsaneieceasentasenccesasesscessonancesacecessiiens 19 21 Sending Nee ae AE 19 42 oud PROTOCOL
9. ask Subnet mask of the WIZ220IO module Gateway address Gateway address of the WIZ220I0 module Warning Be sure to input correct network information If you input incorrect information it can cause network collision or mal function HTTP Port Number You can change webserver s listen port number The HTTP default port number is 80 14 Ww IZnet Notification Options Protocol The WIZ220I0 can send VO values to the specified host The notification protocol can be set as TCP server or TCP client or UDP mode The TCP Server waits for the connection trial from the host The TCP Client tries to connect to the host s IP address and port number At the UDP mode the connection establishment is not defined After setting the IP address and port number of the host just send data WIZ22010 User Manual V1 1 Notification Options Listen Port Number It is valid only on TCP Server mode The WIZ220I0 module will accept connection with listen port number Notification Options Remote IP Address Remote Port Number It is valid on TCP Client and UDP modes Input the host IP address and port number Notification Options Keep TCP connection If you check this option the WIZ220I0 module maintains the connection as sending keep alive packet If you uncheck this option the module closes the connection after sending data Notification Options Time period to sending It is possible
10. ch Table 2 WIZ220I0 Base Board Specification WiZnet WIZ22010 User Manual V1 1 1 3 Block Diagram MONITOR STATION _ COMPUTER Application Program Web Browser Ethernet Control amp Monitoring Transmit VO status amp Output Control Sensor Interface Switch Control P Contro Relay se d vcve Digital VO Relay Alarm System Calibration Device System Monitoring RS 232 Device Figure 1 Block Diagram WIZ220I0 includes not only VO controlling amp monitoring but also VO value transmission functions The users can control or monitor via web browser in remote host PC and configure the module s environment parameters and check the IO status via Configuration Tool program provided by WIZnet The interface of WIZ220I0 consists of analog interface and digital interface 12 bits resolution analog VO 3 3V digital output and the maximum 5 5V digital input are supported by WIZ220I0 The digital I Os are internally pulled up The users can use Web browser or Configuration Tool to remotely control the interfaces Also user can control output port by transmitting control data through the notification port WiZnet 2 WIZ22010 Base Board WIZ220I0 module can be tested by using base board WIZ22010 User Manual V1 1 Figure 2 WIZ22010 Base Board Layout WIZ22010 Module Connector It is an interface for WIZ22010 Module Caution Observe pin position and align when mounting the
11. e original packing materials 3 Any service issue please contact to sales wiznet co kr 24 Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery amp Lifecycle Information WlZnet WIZ22010
12. ed port OP 0 Digital Output OP 1 Analog Output 0 OP 2 Analog Output 1 OP 3 UART Output iP 4 fred modules raas OOOO OOOO OOO H or L digital output value It can be set to H 0x48 or L Ox4C If this value is not H or LU port output is not changed 2 0x0000 analog output 0 The range of value is 0x0000 0x0FFF IE AO 1 2 0x0000 analog output 1 The range of value is 0x0000 0x0FFF OXOFFF If you input this over OxOFFF it will be set OxOFFF UART variable UART value can be inputted max 32 bytes If data is null Ox00 the module stop output UART data End char 1 00 end char of notification receiving parameter Table 6 Receiving parameter description in the notification function Total data size 59 bytes User should send whole control data at a time The module does not control output port as below conditions Mm mismatch ID value m OP n value is not O 0x4F 20 WiZnet R mismatch IP value You should input module s IP address as hex value WIZ22010 User Manual V1 1 R mismatch End char value If you send data to module over 59 bytes excess data will be ignored 21 Wiznet WIZ22010 User Manual V1 1 5 WIZ22010 Specification 5 1 Electrical Characteristics Parameters Min Typ Max Units Input Voltage Vcc 4 5 5 5 5 V High Level Digital Input 2 0 5 5 V Low Level Digital Input 0 5 0 8 V High Lev
13. el Digital Output 3 3 V Low Level Digital Output 0 4 V Digital Output Current 8 mA Analog Input Range Vss Vcc V Analog Input Leakage Current 001 1 HA Analog Output Range 0 4 V Analog Output Short Circuit Current 15 24 mA Operation Temperature 0 70 G Storage Temperature 40 85 iC Power Consumption DC5V 280 mA Table 7 Electrical characteristics 5 2 Pin Header 2x10Pin Dual Line 2 54mm Pitch 12mm height Lead length 6mm Straight Type Gold Plating Current Rating 1A Insulation Resistance 500Mohm Dielectric Withstanding Voltage 500VAC 5 3 RJ 45 connector Pin Signal 1 TX 2 TX 3 RX 6 RX Link LED Active LED Figure 14 RJ 45 PIN Assignment Table 8 RJ 45 Pin Assignment aD Wiznet 5 4 Board Dimensions and Pin Assignment WIZ22010 User Manual V1 1 B Di a AAR meeeccocoooe is os s eeeeeeeeee Hao E 5 55 hoe a H w HIG Z G TEE MR LT ES TOU WIZ22010 eee 4 sEm 1O AO Figure 15 WIZ220IO Module Dimension Symbol mm A 45 00 ay 2 18 ae 4 00 B 66 50 D 63 00 be 13 34 bs 4 00 C 3 00 Table 9 WIZ2201O Dimension 23 Ww IZnet 6 Warranty WIZ22010 User Manual V1 1 WIZnet Co Ltd offers the following limited warranties applicable only to the original purchaser
14. ning If module does not have valid network information Direct IP Search is not available If the module is connected to the NAT or private network it is not possible to connect to the module from outside Search The Search function is used to search all modules existing on the same LAN By using UDP broadcast all modules on the same subnet will be searched The searched module is displayed as MAC address in the Board List Setting This function is to complete the configuration change If you select the MAC address from the Board List the current configuration values of the module will be displayed Change the configuration value and click Setting button to complete the configuration After that the module will re initialize with the changed configuration Webpage It is possible to upload ROM Image file to the internal flash memory of WIZ220I0 For more information refer to 3 6 Webpage Upload Upload It is possible to upload new firmware file through the Ethernet For more information refer to 3 5 Firmware Download Ping It is used to test whether the WIZ220IO module is reachable across a network from your PC with ICMP protocol After inputting host IP address in new pop up window click the PING button Then it will be displayed its result Firewall It controls your PC s firewall configuration If board list does not display even though clicking search button check your PC s fi
15. ption WIZ22010 Configuration Tool ver 1 1 0 FW Version J Enable Serial Debug Mode Board list Network serial Input output IP Configuration Method Static DHCP Module s Network Configuration Local IP Address subnet Mask Gateway Address HTTP Port Number Notification Options m Protocol TCP Server TCP Client UDP Listen Port Number Remote IP Address Remote Port Number Keep TCP connection Time period to sending il0ms E DO 6 0 Search Setting Webpage Upload Ping Firewall En O Direct IP Search Figure 8 Configuration Tool FW Version It displays firmware version s 12 s Ww IZnet Enable Serial Debug Mode If this mode is checked you can monitor the status and socket message listen OK connect fail etc through serial terminal WIZ22010 User Manual V1 1 Board List If you click the SEARCH button all the MAC address on a same subnet will be displayed When you check the Direct IP Search and enter the specified IP address the board list will display its MAC address Direct IP Search Direct IP Search can be used for searching WIZ220I0 which is not installed in the same subnet If the Direct IP Search is checked the configuration tool use the TCP instead of UDP broadcast to search the module Therefore network information of the module such as IP address subnet mask and gateway address is required for the search War
16. rewall Exit Close the configuration tool program 3 2 Network Tab In the Network Tab of the configuration tool network information and the notification parameters can be set The network information is for a communication through the Ethernet such as an IP address a gateway address and a subnet mask If the module cannot be assigned with the fixed information from ISP provider you can set the DHCP option By setting DHCP option the network information can 13 Wiznet be assigned by DHCP server The notification option is a function for sending the I O values to the specified host every specified period It is useful for acquiring data log WIZ22010 User Manual V1 1 Network serial Input Output IP Configuration Method Static DHCP Module s Network Configuration Local IP Address f subnet Mask i SY Gateway Address f HTTP Port Number T Notification Options Protocol TCP Server TCP Client UDP Listen Port Number Remote IP Address Remote Port Number Keep TCP connection Time period to sending 10ms Figure 9 Network Tab of the Configuration Tool IP Configuration Method You can select STATIC or DHCP The STATIC option can be selected when your network resource can give the fixed IP address and the DHCP option can be selected when your network has DHCP server such as a router who has DHCP server function Local IP Address IP address of the WIZ220I0 module Subnet M
17. s button Warning There is limitation of file number in selecting at a time Normally max 15 files can be selected simultaneously If there are more files use Add Files button for the several times Select Rom Image File option If you click Make Image button rom file can be created Warning The limitation of the ROM image size is 20476bytes If the file size is over 20476bytes it does not guarantee the normal operation 18 WiZnet 4 Notification Data Protocol WIZ22010 User Manual V1 1 WIZ22010 uses the pre defined notification protocol to transfer the I O status to the specified server and control the output port by using received commands Both TCP and UDP are supported in this function In the TCP mode socket should be established for exchanging data 4 1 Sending Protocol The length of I O status data to be transferred is 45 bytes in total The data format is defined as follows 0 1 2 3 4 5 6 T 8 9 A B C D E F 0x00 ID SEQ MAC address 0x10 TP address DITO DIT DIR DIB DI 4 DIST DI 6 DI 7 DOL DOL DORI DOL 0x20 DOM DOST DOI6 DO ALO AL 1 AO 0 AOI End char Table 3 Frame format of notification sending parameters Fea szene vawe Description CS DEE EI T E variable Sina number of data transmission ELE comes mae 6 fied modules MaCeddress ip 4 mea modules adores O OOOO H or U
18. the WIZ220I0 You can see below status window showing Status Window Processing Processing Figure 12 Firmware uploading window If the file is uploaded Complete firmware uploading message will be displayed Status Window Complete firmware uploading Figure 13 Complete firmware uploading window 3 6 Webpage Upload Execute WIZ220I0 configuration tool and click Search button Ifthe module is correctly connected to the network its MAC address is displayed on the Board list Select the board at the Board list and click web page Upload button Warning Before uploading through Ethernet the network information should be set for correct network communication The configuration tool send ping request automatically and if there is no reply from board it will display error message When the dialog box is shown select the Flash Rom File System rom file and click OPEN button Warning The Flash Rom File system should be created by usinig Rom File Maker Tool rev3 0 For the detail refer to 3 6 1 Use of Rom File Maker rev3 0 If the file is uploaded Complete webpage uploading message will be displayed a 7s Wiznet WIZ22010 User Manual V1 1 3 7 Rom File Maker rev3 0 Rom File Maker rev3 0 is the tool for creating ROM Image which enables the webpage to be stored in the Flash memory Select the webpage by using Add File
19. to set the sending period To disable notification option input 0 to this parameter Causion In the firmware version1 0 this parameter s unit is the 1 second From the firmware version1 1 the unit is the 10ms 3 3 Serial Tab Serial tab is for the UART configuration The UART is used to display debug message and to output the UART data through the webpage Network k Input Output Speed DataBit X Parity ian Stop Bit Flow d Figure 10 Serial Tab of the Configuration Tool Speed It supports baud rate from 1200bps to 230400bps Data Bit It supports 7bit or 8bit of data bit Parity It supports odd even and none option of parity Stop Bit It supports only 1bit Flow It supports flow control none RTS CTS 15 Wiznet 3 4 Input Output Tab WIZ22010 User Manual V1 1 Input Output tab is for the I O control and monitoring When you click the Update VO Status button it will be displayed VO parameters at that time In the Digital parameters a green indicator means port is asserted HIGH and a gray indicator means LOW Each port can be set HIGH as checking checkbox in Digital Output Control and click the Update VO Status button The Analog I O has range from 0 to 4095 and it has voltage type In the Analog input status 4095 means maximum input value that is same to 5V_Input Vcc value However analog output ma
20. ximum value 4095 generates 4V In other word the analog output maximum value is 4V Warning At the digital input if you set the switch on the base board module recognizes it as low At the digital output when the module is low LED on the base board becomes on y Network Serial Input Outp dj Digital Input Status Digital Output Control pL 0 DO 0 T DI 1 DO 1 F DI 2 DO 2 T DI 3 DO 3 IT DI 4 DO 4 IT DI 5 DO 5 T DI 6 DO 6 T oO DI_7 DO 7 T Analog Input Status Analog Output Control Aaro AD 0 rie AD 1 Analog Input Output Range 0 4095 Update I 0 States in every 0 5 Seconds Figure 11 Input Output Tab of the Configuration Tool 3 5 Firmware Upload Execute WIZ22010 configuration tool and click Search button If the module is correctly connected to the network its MAC address is displayed on the Board list Select the board at the Board list and click Upload button 16 WiZnet Warning Before uploading through Ethernet the network information should be set for correct network communication The configuration tool send ping request automatically and if there is no reply from board it will display error message WIZ22010 User Manual V1 1 When the dialog box is shown select the Binary file and click OPEN button Warning Be sure to use firmware only for