Home

FN-DA04AH11 - Pro-face America HMI Store

image

Contents

1. CPEV S 0 up to 0 9mm 2 core shielded e Use the same type crimp terminals as used for the communication cable Confirm that all I O unit terminal screws are securely tightened even they are not used Important Note Please be aware that Digital Electron ics Corporation shall not be held li able by the user for any damages Digital Electronics Corporation 8 2 52 Nanko higashi Suminoe ku Osaka 559 0031 JAPAN Tel 81 0 6 6613 1101 Fax 81 0 6 6613 5888 URL http www proface co jp losses or third party claims arising from the uses of this product Copyright 2000 Digital Electronics Corporation All rights reserved
2. You can download the latest driver from Pro face s Home Page For GP3000 Series You can select the Flex Network Driver via GP Pro EX as an I O driver Also you can download the driver and the Flex Network Analog Unit User Manual from Pro face s web site http www pro face com Installation E Installing the unit on a 35 mm DIN Rail Installation Removal Hook the analog unit s top face groove Use a screwdriver to push the attach over the top edge of the DIN rail Next ment hook down and release the unit push the bottom of the I O unit forward Then pull the unit forward and off until the attachment hook clicks into the rail place on the DIN rail DIN rail a Flat head screwdriver Digital Analog conversion unit Push down A Be sure that the top and bottom faces of the unit are facing L the correct direction and the unit is installed in a vertical posi Important tion Incorrect installation may prevent heat from dissipating E Installing the unit in a Panel Create installation screw holes for installing the unit using the dimensions given below Secure the analog unit in place with M4 size screws Screw torque should be 1 0 to 1 3 Nem Unit mm in 158 0 1 5 6 22 0 06 2 M4 os _ ag 25 O 9 T2 On i O 158 04 1 5 oe T 6 22 0 06 Wiring This section describes both the cables and crimp terminals used for wiring each t
3. from the sensor s power supply to prevent the unit from being affected by external noise e Use two FG terminals with 4 channels and use one FG terminal with 2 channels Driver amp Manual E To Prevent Unit Damage e Do not store or operate this unit in either direct sunlight or excessively dusty or dirty environments e Since this unit is a precision instrument do not store or use it in locations where excessive shocks or vibration may occur e Do not block this unit s ventilation holes or operate it in an environment that may cause it to overheat e Do not operate this unit in locations where sudden temperature changes can cause condensation to form inside the unit e Do not use paint thinner or organic solvents to clean this unit Package Contents Flex Network 4 Channel Digital Analog Conversion Unit FN DA04AH11 Flex Network 4 Channel Digital Analog Conversion Unit Installation Guide this guide 2 3 o Pro face Frasi POWER 24VDC oT a The driver for the Flex Network Unit is required in order to use the unit For GLC2000 Series and LT Series You can select the Flex Network Driver via GP PRO PBIII C Package Pro Control Editor or LT Editor If the selection of the appropriate unit s name does not appear in the I O Configuration I O Unit Settings area you will need to update the driver file
4. Flex Network 4 Channel Digital Analog Conversion Unit Installation Guide Thank you for purchasing Pro face s Flex Network 4 Channel Digital Analog Conversion Unit FN DA04AH11 To ensure correct use of this unit s functions and features be sure to carefully read both this Installation Guide and the Flex Network Analog Unit User Manual Flex Network 4 Channel Digital Analog Conversion Unit FN DA04AH11 is not CE marked UL c UL CSA listed products Safety Precautions This guide contains a variety of safety symbols for safe and correct operation of this unit Please read this installation guide and any related manuals care fully to fully understand how to correctly use this unit s functions E Safety Symbols This guide uses the following symbols for important information related to the safe and correct operation of this unit Please pay attention to these sym bols and follow all instructions given A hazardous situation that will result in death or major equipment damage if instructions are not followed AN A potentially hazardous situation that could result in death Waming or major equipment damage if instructions are not followed A potentially hazardous situation that could result in minor injury or equipment damage if instructions are not followed e An emergency stop circuit and an interlock circuit should be constructed outside of this unit Constructing these circuits inside this unit may cause a runaway situat
5. e high current line high frequency lines such as inverter lines and the power cord Otherwise a malfunction may occur due to noise This unit must be properly installed according to directions in the Installa tion Guide and User Manual Improper installation may cause the unit to malfunction or operate incorrectly This unit must be properly wired according to directions in the Installation Guide and User Manual Improper wiring may cause a unit malfunction failure or electric shock Do not allow foreign substances including chips wire pieces water or liquids to enter inside this unit s case Otherwise a malfunction failure electric shock or fire may occur When disposing of this unit it should be disposed of according to your a Specifications E Electrical Control Section AC 1500V 1omA minute between input output and FG terminals AC500V 1minute between power supply ist level and 2nd level Insulation Resistance 10MQ or more at DC500V via noise simulator between charging and FG terminals E Environmental Ambient Operating 0T to 55 C Temperature Ambient Storage 25 to 70 C Temperature Ambient Humidity 30 RH to 95 RH non condensation level RH 1 Rating ua E Output Number of Output Channel 4ch fixed Upto 2 miliseconds Output Range 10V to 10V Impedance 1KQ OmA to 20mA Impedance 400Q 4mA to 20mA Impedance 4000 Output Range Switch Depends on rotary switch settin
6. gs Offset Gain setting Setting the upper limit value lower limit value for each range via switch 0 3 FS 25 C 0 5 FS 0 C to 55 C Photocoupler insulation output terminals between internal circuits Convert all channels at all time not selectable 1 For continuous output to 4 channels at the same time with FN DA04AH11 the output current for 1 channel should be 10mA or less Or the total current of all channels should be 40mA or less Calibration Function Insulation Method country s industrial waste disposal laws 4 Channel Analog Unit Wiring This section explains the Flex Network 4 Channel Digital Analog Conver sion Unit Connection and Circuit Drawings The left drawing explains the connection using chl and ch3 as row Each channel can be used connecting to voltage input units or current input units Current Input Device Device Ch 1 output voltage terminals cccccceeceeeececeeeeeeeeeeeeeeeeeees V1 AGI FG Ch 1 output current terminals ji csiccisiedenaovnvirinaatysasiinudinobandwanwivonnstcdes I AG1 FG Output Circuit Drawing D A N Voltage Output Conver o 4 Vi Voltage sion put ni lt b gt gt Q T O IEA D A Current Output Conver I i i Current sion Input AG Unit FG Pate e The analog unit s power supply should be separated
7. ion system failure or an accident due to unit failure Systems using this unit should be designed so that output signals which could cause a serious accident are monitored from outside the unit This unit is designed to be a general purpose device for general indus tries and is neither designed nor produced to be used with equipment or systems in potentially life threatening conditions If you are considering using this unit for special uses including nuclear power control devices electric power devices aerospace equipment medical life support equip ment or transportation vehicles please contact your local Flex Network distributor e Whenever installing dismantling wiring and conducting maintenance or inspections be sure to disconnect power to this unit to prevent the possi bility of electric shock or fire Do not disassemble or modify this unit since it may lead to an electric shock or fire Do not use this unit in an environment that contains flammable gases since it may cause an explosion Do not use this unit in an environment with conditions outside of the ranges specified in this Installation Guide and in the User Manual Otherwise an electric shock fire malfunction or other failure may occur Because of the possibility of an electric shock or malfunction do not touch the power terminals while the unit is operating e Communication cables or I O signal lines must be wired separately from the main circuit high voltag
8. o settings WWI ecco N Non Hold Dip Switch S No Station no N 6 H Hold S No p Cem sma Sate 6 6 Mbps l p ae 10h 16 E LEa iag a SONNE ssesisisss H12 12 12 Mbps SW3 4 UP ON 1 K189 of TNO Down OFF 0 CAE Arrow tip Setting values aa Sul ONG ONG N 6 e 3Fh 63 IE co TERM OFF Termination OFF Sooo OFF ON ON Termination ON H E Communication Cable The Flex Network interface and the analog unit or all distributed analog units are connected using a cross wiring system T type systems cannot be used Pro face suggests the following communication cables Pro ace When preparing the cable wire ends Cover shielded wires with shield tape or with an insulation tube Use insulated crimp terminals If you use a pressure connection terminal without insulation cover it with a shield tape or an insulation tube Cover uninsulated crimp termials with shield tape or a tube type insulation N 6 Blue TR 3 8 0 15 Unit mm in or less p 5 2 0 20 or longer ag oo z O Shield wire SLD 3 2 90 13 or larger E Power Cable e Cable diameter can be up to 1 25 mm7 Be sure to twist all wire ends before attaching crimp terminals e Use the same type crimp terminals as used for the communication cable E Analog Output Cable e Cable diameter can be up to 0 9 mm
9. ype of cable The terminal screw torque should be 0 6 to 1 0 Nem fa External Dimensions Part Names This section shows the external dimensions of the digital analog conversion unit part names and part settings 168 6 61 Unit mm in Side View Factory Default settings Communication speed 6 Mbps S No station no 0 Output Hold Non Hold N Bottom View A Dip Switches lt ciscvesscanersxncereess Set communication speeds and S No first digit B S No station no Switch Sets S No last digit C Terminator sccecesncasctavsavatecdoratys Switches termination ON OFF Turns ON the units at both ends of the communication cable D Status LED ceccccccnermescesvaresaanenas Indicates the unit s current status E Calibration Select Switch Selects a calibration setting Refer to Table 1 F Calibration Perform Switch Pushing this swith performs the calibration of the DA output s lower limit value MIN and upper limit value MAX G Range Switch vccsiisssctessecactaace Switches a range setting Refer to Table 2 H DIN Rail Attachment Hook is used to attach the unit to a DIN rail Table 1 Table 2 pT CH4 DA Lower Upper Limit Values Setting 1 The factory setting is 0 es es Ov SU PV 10 Pp 20MAV 1 The factory setting is O 0 to 5V Switch Settings Examples of S No station n

Download Pdf Manuals

image

Related Search

Related Contents

MODE D`EMPLOI Enceinte 2 voies haute-définition  Boyo Back Up Sensor Systems Users Manual    VCM SERIES User's Manual  Les ex - Camille_version allégée  Cardo S-2TM Headphones User Manual  取扱説明書 - The Simple  o((l Department of School & Mass Education, Govt. Of - e  Digital Readouts/PC Solutions  DAV-SB200  