1. DAEnetIP2 User Manual DAEnetIP2 User Manual Date 22 03 2012 www DENKOVI com 1 SSEMBL DAEnetIP2 User Manual Content 1 Basic features 2 unc Be puc cc TRETEN Tm 4 2 uo REPRE 5 d Product CLL CCS eae 6 mE eA o igen etic RR fi 0 Connectors and LED ORE odii pius bild 9 TI HU ONUS ou E M E ELEM 11 8 9 www DENKOVI com 2 CUT 1 Basic features DAEnetIP2 is multifunctional device for management and control It could be used for industrial automatization access control fire and security systems It is suitable also for controlling relay boards and tracking different sensors via internet 10 Mb Ethernet interface with Link Activity Led Low power consuption lt 50mA 12V Power supply 7 5 25V Standart protocols ARP IP ICMP ping SNMP v1 snmpget snmpset snmp traps Web TFTP firmware update Two MAC addresses protection It can be configurated with SNMP requests 2x8 digital outputs 1x8 combined analog or digital inputs with 10 bit ADC 0 3 3V Integrated WEB server with authorization for all functions parameters access Size 43mm x 55mm www DENKOVI com DAEnetIP2 User Manual 8 SSEMBL e RERO DAEnetIP2 User Manual 2 Technical parameters Digitalinputscount 8
2. Yes Web SNMP Enable Disable TFTP update 1 Digital inputs are the analog inputs but the input voltage is converted to 1 or 0 www DENKOVI com 4 DAEnetIP2 User Manual 3 Application examples 3 1 Remote control DAEnetIP2 e Internet Relay Board Power supply Electrical device 3 2 Data acquisition Sensor Sensor Sensor DAEnetIP 2 DAEnetIP 2 2 Vie 5 SNMP Monitoring Software SNMP Trap www DENKOVI com 5 SSEMBL DAEnetIP2 User Manual 4 Product installation 1 Connect the DAEnetIP2 with PC or router with UTP cable 2 3 Your PC IP should be in the DAEnetlP2 network initially So it is Supply the DAEnetIP2 controller 12VDC stabilized recommend recommend to be 172 16 100 1 If you have router make the router IP 172 16 100 3 Open web browser and type 172 16 100 2 username password are admin admin Access the module via Web WWW DENKOVI com 6 SSEMBL DAEnetIP2 User Manual 5 Default Settings 5 1 Table with default settings These are the default factory settings of DAEnetlP2 When you buy the controller you will receive it with these settings Parameter Value 1172161002 Mask 2552552550 2 21 www DENKOVI com 7 DAEnetIP2 User Manual 5 2 Steps for loading default settings P
3. 14 DAEnetIP2 User Manual 7 3 3 Mode Low High The output will be set if the input level is out of the range with High and Low Threshold 7 3 4 Mode Acc The output will be set if the input level is less than Low Threshold and will be in old state after input level is over High Threshold This function does not affect to SNMP traps but the same Threshold values are used for sending SNMP traps 7 4 Ports 2 172 16 100 2 ir ports control BS egre ug 3 en P3 Output P5 Output P6 y v 7 y y 72 y Input 1 829v 3 09 2 194 3 11V 2 384V 3 229V 3 01V 3 094V Restart target device P3 and P5 are two 8 channel digital output ports P6 is 8 channel 1024 bit analog input port The reference voltage is 3 3VDC Also P6 can be used as digital input port If the value is greather than 1 65V this is 71 otherwise 70 Via snmp this is parameter pctriP6byte 0 When this command is send the module will return one byte with converted analog input values 1 0 In this way the port can be used either as analog either as digital inputs www DENKOVI com 15 DAEnetIP2 User Manual 7 5 Account 2 172 16 100 2 username Password Confirm password Both username and password must be 4 12 characters long Firmware Update Reboot 172 16 100 2 acco
4. the module 7 1 5 Default Gateway The Default gateway of the module www DENKOVI com 12 SSEMBL DAEnetIP2 User Manual 7 1 6 VLAN DAEnetIP2 can work with normal or tagged packets IEE 802 11q It supports the whole set of 12bit VLAN tags 7 1 7 DHCP The IP MASK and Gateway can be broght by DHCP server 7 1 8 MAC filtering DAEnetIP2 has MAC protection This means that if it is enabled it can be accessed from one two MAC addresses For disable the MAC protection the MAC must be 000000000000 7 1 9 SNMP Web Access network This function determine which IP MASK network will access the module through SNMP and Web The filtering is for SNMP Web ARP ICMP DHCP Note that MAC protection is with higher priority than SNMP Web access protection 7 1 10 SNMP settings This section is for enable disable SNMP access and SNMP community strings 7 1 11 ICMP monitoring modes ICMP settings 7 1 12 TFTP firmware update DAEnetlP2 has TFTP client for firmware update When the command is initiated the DAEnetIP2 module connects to the TFTP server and starts downloading the firmware version After checking if there is connection with the TFTP server and if the file is correct the firmware will be updated and the module will be rebooted 7 1 13 Broadcast frames In this mode DAEnetIP2 does not response of frames with MAC address FF FF FF FF FF FF This allows DAEnetIP2 to hide from the world because it
5. to configure DAEnetIP2 via IE Mozilla Chrome or other browser The browser must support JavaScript There is username and password Basic Authentication The web server has only one session only one user can access the 2 via web at a time The session has timeout 60 seconds if there is not access from the browser After that another user can access the module This is done because of the security www DENKOVI com 11 DAEnetIP2 User Manual 7 1 Setup DAEnetIP2 C 0 17216 100 2 configuration Firmware version MAC address 02 60 43 63 13 62 address 172 16 100 E Subnet mask Jes Em Default gateway s 1 100 m i Tagged mode DHCP client Ingress MAC Filter Access MAC address 1 000000000000 Access MAC address 2 000000000000 set both to all zeroes to disable MAC security SNMP Web Access network Network IP 172 100 NetworkMask p jb set mask to 0 0 0 0 to disable IP filtering SNMP settings SNMP access to IP configuration SNMP read write community string 4 13 symbols 172 16 100 2 system htm SNMP read only community string 000000000000 4 13 symbols 7 1 1 Firmware version This is the current firmware version Can not be changed 7 1 2 address The MAC address of the module Can not be changed 7 1 3 address The IP address of the module 7 1 4 Subnet Mask The subnet mask of
6. 1 0 pctrlP5pin1 read write Port5 pin1 data INTEGER High 1 Low 0 x 1 2 2 2 0 pctriP5pin2 read write Port5 pin2 data INTEGER High 1 Low 0 x 1 2 2 3 0 pctriP5pin3 read write Port5 pin3 data INTEGER High 1 Low 0 x 1 2 2 4 0 pctrlP5pin4 read write Port5 pin4 data INTEGER High 1 Low 0 High 1 Low 0 x 1 2 2 6 0 pctriP5pin6 read write Port5 pin6 data 1 Low A par 1 2 2 33 0 pctriP5byte I O port data as INTEGER 0 255 www DENKOVI com 21 SSEMBL DAEnetIP2 User Manual 4 single byte po 8 7 Returned values are from 10bit Analog to Digital Convertor Description Syntax 412250 1 2 3 6 0 www DENKOVI com 22 DAEnetIP2 User Manual 9 Appendix 1 Power supply The minimal power supply is 7 5VDC The maximum voltage is 25VDC The optimal voltage is 12VDC 12 Power Terminal www DENKOVI com 23 DAEnetIP2 User Manual 10 Appendix 2 Connections 10 1 Connection to PC UTP crossover cable Ethernet controller 10 2 Connection to router Router UTP straight thru cable Ethernet controller www DENKOVI com 24 SSEMBL DAEnetIP2 User Manual 11 Appendix 3 I O Ports They are not buffered and you should very carefully otherwise the MCU could be damaged They are digital inputs outputs The o
7. doesn t respond to ARP requests 7 1 14 Web server Enable disable web access WWW DENKOVI com 3 DAEnetIP2 User Manual 7 2 SNMP traps DAEnetIP2 0 17216 100 2 Target SNMP host e 1 address 72 set 0 0 0 0 to disable generation of trap messages Community string public 4 13 symbols Analog events and output control 1 2 3 4 5 6 7 8 gt 1023 gt 1023 2 1023 gt 1023 gt 1023 gt 1023 v gt 1023 set Low 0 High 1023 to disable trap on channel 172 16 100 2 traps htm SNMP traps can be generated from Analog inputs if its level crosses the given limits If the limits are O and 1023 then there will not be any traps from this input The message gives information from which input is this trap and what is the input level value If several events are generated DAEnetIP2 sends their traps in order they have been generated 7 3 Analog events DAEnetlP2 Analog inputs could be attached to P5 digital output port When analog input is changed the corresponding digital output can react There are 4 modes 7 3 1 Mode Low The output will become 1 if the input level is less than Low Threshold and sets the previous state when the input level is over Low Threshold 7 3 2 Mode High The output will be set if the input level is higher than High www DENKOVI com
8. osition 2 Position 1 Turn off the power supply of the IP controller Move the jumper from position 1 to position 2 Turn on the power supply of the IP controller Move the jumper from position 2 to position 1 Turn off the power supply of the IP controller Turn on the power supply of the IP controller www DENKOVI com 8 DAEnetIP2 User Manual 6 Connectors and LED indicators 6 1 DAEnetIP2 ports view Reset to Default B www DENKOVI com 9 SSEMBL DAEnetIP2 User Manual 6 2 DAEnetIP2 ports description Port JP3 P3 Port JP4 P5 Port JP5 P6 digital outputs digital outputs digital analog inputs Func Dir Bit Func Free Out 6 Free Free Out 8 GND PWR 3 3V PWR GND PWR GND Port JP6 system port Func Dir Reserved Ping LED Bt pee pl MEN ut EET EE Reserved 2 82 7 CK GND PWR e Free the pin is free to be used by user e the pin is reserved for special function can not be accessed e n the pin is input e Out the pin is output e Ain analog input www DENKOVI com 10 DAEnetIP2 User Manual 7 Web access DAEnetIP2 Q Q 172 16 100 2 Setup SNMP traps Fae ports Welcome to DAEnetIP2 ASSEMBLY ELECTRONICS LTD It is possible
9. rrent in the sensor resistor However the resistor divisor makes also the ADC conversion bigger www DENKOVI com 26 SSEMBL DAEnetIP2 User Manual 12 2 LM35Z LM34 12VDC from DAEnetlIP2 LM35DZ OR LM34 DAEnetIP2 P6 X When using LM35DZ LM34 all the disadvantages of LM335 are avoided there is no need of current resistor as this sensor does not work as zener diode neither output divisor Also its initial error is better than LM335 The only disadvantage is the minimal voltage is 4VDC 5VDC for LM34 this makes the connection to DAEnetlP2 more difficult it can not be connected directly with only single jumper to P6 www DENKOVI com 27 SSEMBL DAEnetIP2 User Manual 12 3 MCP9700A 3 3 VDC from DAEnetIP2 MCP9700A DAEnetIP2 P6 X This sensor MCP9700A works in range 2 3 5 5V and that allows to be supplied from 3 3V pin which is mapped to P6 jumper Generally its parameters are better than the LM335Z and LM35DZ 34 www DENKOVI com 28 DAEnetIP2 User Manual 13 Appendix 5 Mechanical draw 40 41 4 28 829 www DENKOVI com 29
10. tiation of firmware update procedure according to system settings 8 2 Analog traps Access Description Syntax INTEGER 0 1023 INTEGER 0 1023 INTEGER 0 1023 INTEGER 0 1023 INTEGER 0 1023 8 3 Anolog to P5 Events OD Access Description Syntax x 1 1 121 1 0 aevPin1 read write Defines reaction on INTEGER respective P5 output None 0 pin when voltage Low 1 High 2 compared to LowHigh 3 thresholds 4 x 1 1 121 2 0 aevPin2 read write Defines reaction INTEGER respective P5 output None 0 pin when voltage is Low 1 High 2 compared to LowHigh 3 thresholds 4 x 1 1 121 3 0 aevPin3 read write Defines reaction INTEGER respective P5 output None 0 pin when voltage Low 1 High 2 compared to LowHigh 3 thresholds 4 WWW DENKOVI com 9 Br x 1 1 121 4 0 x 1 1 121 5 0 x 1 1 121 6 0 x 1 1 121 7 0 x 1 1 121 8 0 8 4 x 1 2 1 0 read write read write Control ports OD x 1 2 1 0 pctrPort3 octriPort3 DAEnetIP2 User Manual Defines reaction on respective P5 output pin when voltage is compared to thresholds Defines reaction on respective P5 output pin when voltage is compared to thresholds Defines reaction on respective P5 output pin when voltage is compared to thresholds Defines reaction on respective P5 output pin when voltage is compared
11. to thresholds Defines reaction on respective P5 output pin when voltage is compared to thresholds INTEGER None 0 Low 1 High 2 LowHigh 3 4 INTEGER None 0 Low 1 High 2 LowHigh 3 4 INTEGER None 0 Low 1 High 2 LowHigh 3 4 INTEGER None 0 Low 1 High 2 LowHigh 3 4 INTEGER None 0 Low 1 High 2 LowHigh 3 4 Access Description Syntax 1 2 1 port data NTEGER 0 255 x 1 2 2 0 5 port data INTEGER 0 255 x 1 2 3 0 port data NTEGER 0 255 8 5 1 2 1 2 0 pctriP3pin2 x 1 2 1 3 0 pctriP3pin3 www DENKOVI com read write read write Control port P3 Digital outputs Access 1 2 1 1 0 pctriP3pin1 read Port3 pin1 data write Port3 2 data Port3 pin3 data INTEGER High 1 Low 0 INTEGER High 1 Low 0 INTEGER High 1 Low 0 220 SSEMBL DAEnetIP2 User Manual x 1 2 1 4 0 4 Port3 pin4 data INTEGER write x 1 2 1 5 0 pctriIP3pin5 read Port3 pin5 data write x 1 2 1 6 0 pctriP3pin6 read Port3 pin6 data INTEGER write High 1 Low 0 x 1 2 1 7 0 pctriP3pin7 read Port3 pin7 data INTEGER write High 1 Low 0 x 1 2 1 8 0 pctriP3pin8 read Port3 pin8 data INTEGER Low 0 write single byte 8 6 Control port P5 Digital outputs OID Name Access x 1 2 2
12. unt htm 7 6 Firmware Update This command starts firmware update The DAEnetIP2 will download the firmware file from the TFTP server given in Setp section After that the device will be rebooted 7 7 Reboot Reboots DAEnetlP2 www DENKOVI com 16 SSEMBL lt I DAEnetIP2 User Manual 8 SNMP access DAEnetIP2 supports SNMPv1 protocol snmpget snmpset It may be configured read all the parameters via these commands Read only community string is used for reading and Read Write Community String is used for changing the parameters Note that it is not possible using of snmpwalk Parameters that can be changed are grouped according to their functions in the tables below To obtain a valid OID number it is necessary to replace the x symbol with the prefix 1 3 6 1 4 1 19865 Also all the snmp commands descriped the file DAEnetIP2 mib All the functions can be accessed via SNMP and WEB 8 1 Configuration settings Access OID Access 1 1 1 0 cfgIP read write IP Address of IpAddress pe oll VEAN IDA NE 1 095 X tni 1 4 0 cfgPassword read write Read Write community OCTET string password STRING SIZE 4 12 CfgMACLock1 read write MAC address of first PhysAddress remote machine allowed to access DAEnetIP2 module cfgMACLock2_ read write MAC address of second PhysAddress remote machine allowed to access DAEnetIP2 module 1 1 8 0 cfgVersion read only Firm
13. utput level voltage is 1 3 3VDC or 0 0 25VDC with consumption lt 1 5mA All inputs outputs have protection diodes to GND and 3 3VDC Below are given sample examples of l O ports connections to external devices The first figure shows connection with 12V relay The second shows example for 5V TTL signal input R2 is recommend because sometimes the input signals are tri state 12V P1 12V 4000M VD1 1N4148 VT1 h21e 150 From Out port e 5V TTL Signal R2 To In port 22k www DENKOVI com 25 SSEMBL DAEnetIP2 User Manual 12 Appendix 4 Using analog temperature sensors 12 1 LM335Z 12VDC from 2 To DAEnetlP2 P6 X On the figure above it is shown LM335Z connection to DAEnetIP2 with several resistors LM335 may be assumed as zener diode it is necessary to limit the current that s why the 4 7K resistor is added The biggest disadvantage of LM335 is the high output voltage during 25 C As DAEnetIP2 ADC works in range of 0 3 3V actually with directly connected LM335 it is not possible to measure temperatures over 57 C Moreover the output of LM 335Z can exceed 3 3V and damage the ADC channel The easiest solution is using simple resistor divisor 3 1 so the output voltage during 25 C to be 1V It is important the divisor resistance to be smaller because this improves the ADC accuracy but on the other hand it must be taken in mind also the cu
14. ware version 0 LSB VER_MINOR 5535 MSB VER_MAJOR cfgMode read write Contains different bit 0 flags for DAEnetIP2 255 operating modes ENABLED BIT BROADCAST_DISABL E bit1 VLAN_TAG_ENABLE bit2 NO_LARGE_PACKETS bit3 www DENKOVI com 17 DAEnetIP2 User Manual PINGRESTART_ENAB LE bit4 SWITCH_CONTROL bit5 SECONDARY TARGE T bit6 USE_ANALOG_PINS bit7 x 1 1 10 0 cfgReset read only Read of this OID causes rest of DAEnetIP2 module 1 1 11 0 cfgNewMode read write Contains different bit 0 2 flags for DAEnetIP2 55 operating modes SAVE IOPORTS bitO PING LED bit1 PING TIMEOUT IORE SET bit2 TFTP UPDATE bit3 DHCP CLIENT bit4 MONITOR TIMEOUT _ RESTART bit5 WEB SERVER bit6 SWITCH RESTART bit7 1 1 14 0 cfgDefGW IP Address of Default IpAddress Gatewa 1 1 15 0 cfgNetMask IP Network Subnet IpAddress Mask 1 1 17 0 cfgReadOnlyP read write Read only community OCTET assword string password STRING SIZE 4 12 P TRAP manager 1 1 19 0 cfgTrapPassw read write Community string for OCTET ord trap messages STRING SIZE 4 12 class allowed to access DAEnetIP2 k allowed to access DAEnetIP2 server for ss www DENKOVI com 18 SSEMBL lt I DAEnetIP2 User Manual firmwareupdate 1 1 33 0 cfgUpdateFirm read only Read of this OID causes NULL ware ini