1. drain hose is supposed to be done by qualified installer in case of water leakage 3 Bundle the tubing connecting cable and drain hose with tape securely evenly as shown in Figure on the right Because the condensed water from rear Right piping of the indoor unit is gathered in ponding box and is piped out of room Do not put anything else in the box CAUTION Connect the indoor unit first then the outdoor unit e Do not allow the piping to let out from the back of the indoor unit Be careful not to let the drain hose slack Heat insulation should be done to the extension drain hose of indoor unit Be sure that the drain hose is located at the lowest side of the bundle Locating at the upper side can cause drain pan to overflow inside the unit Never intercross nor intertwist the power wire with any other wiring Left back piping 24S Dood z ao Left piping Indoor unit Ponding box Connective Pipe room i Connective pipe Wrapping belt Indoorunitinstallation 1 Pass the piping through the hole in the wall 2 Hook the indoor unit onto the upper portion of installation plate Engage the indoor unit with the upper edge of the installation plate Ensure the hooks are properly seated on the installation plate by moving it in left and right 3 Piping can easily be made by lifting the indoor unit with a cus
2. 202000192582 CS236 BP12FU L 20131022 INSTALLATION MANUAL FOR ROOM AIR CONDITIONER Split Wall Mounted Type INSTALLATION PRECAUTIONS Please read this installation manual carefully before operating the unit to ensure correct installation If the power cord is damaged replacement work shall be performed by authorised personnel only Installation work must be performed in accordance with the national wiring standards by authorised personnel only Contact an authorized service technician for repair maintenance and installation of this unit This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by persons responsible for their safety Children should be supervised to ensure that they do not play with the appliance All the pictures in the instructions are for explanation purposes only The actual shape should prevail The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details SAFETY PRECAUTIONS Please read these safety precautions carefully before installation Be sure to follow all the precautions below they are all important for ensuring safety A WARNING This symbol indicates the possibility of death or serious injur
3. ctionalareaofconductors Ratedcurrent Nominalcross sectional _ NOTE ofappliance area e The wire size of power supply cord and A mm2 interconnected wire and the current of the fuse or switch are determined by the gt 3 and lt 6 0 75 maximum current indicated on the gt 6 and lt 10 1 nameplate which located on the side gt 10 and lt 16 1 5 panel of the unit Please refer to the 316 and lt 25 25 nameplate before selecting the wire size i fuse or switch gt 25 and The controller of the air conditioner 332 and designed with a fuse protection function under abnormal conditions the specifications of the fuse have printed on the circuit board such as T3 15A 250VAC T5A 250VAC etc 60cm or more Connectthecabletotheindoorunit NOTE Before performing any electrical work turn off the main power to the system The inside and outside connecting cable can be connected without removing the front grille 2 The indoor power cord type is HO5VV F or HO5V2V2 F the outdoor power cord and interconnected cord type is HO7RN F Lift the indoor unit panel up remove the electrical box cover by loosening the screw Ensure the colour of wires of outdoor unit and the terminal Nos are the same to the indoor s respectively Wrap those cables not connected with terminals with insulation tapes so that they will not touch any electrical components Secure the cable onto the control board wi
4. door unit For the drain joint with the seal Fig A first fit the seal onto the drain joint then insert the drain joint into the base pan hole of outdoor unit rotate 90 to securely assemble them To install drain joint as shown in Fig B insert the drain joint into the base pan hole of outdoor unit until it remains fixed with a clicking sound Connecting the drain joint with an extension drain hose Locally purchased in case of the water draining off the outdoor unit during the heating mode Base pan hole of outdoor unit E Seal Drain joint Elaring 1 Cut a pipe with a pipe cutter 2 Put flare nuts on pipe tube having completed burr removal and flare the pipe 3 Firmly hold copper pipe in a die in the dimension shown in the table below y Outer diam mm 6 6 35 6 9 52 6 12 7 lt a ANS EDID 4 o 16 Indoor unit tubing Flare nut Pipings Outer diam Additional tightening Tightening torque N cm torque N cm Tightening connection Align pipes to be connected Sufficiently tighten the flare nut with fingers and then tighten it with a spanner and torque wrench as shown Excessive torque can break nut depending on installation conditions 1500 1600 6 35mm 153kgf cm 163kgf cm 2500 2600 9 52mm 255kgf cm 265kgf cm 3500 3600 amp 12 7mm 35 7kgf cm 367kgf cm p 16mm 4500 4700 459k
5. eck Check that all tubing and wiring have been properly connected Check that the gas and liquid side service valves are fully open 1 Connect the power press the ON OFF button on the remote controller to turn the unit on 2 Use the MODE button to select COOL HEAT AUTO and FAN to check if all the functions works well 3 When the ambient temperature is too low lower than 17 C the unit cannot be controlled by the remote controller to run at cooling mode manual operation can be taken Manual operation is used only when the remote controller is disable or maintenance necessary e Hold the panel sides and lift the panel up to an angle until it remains fixed with a clicking sound Press the Manual control button to select the AUTO or COOL the unit will operate under Forced AUTO or COOL mode see User Manual for details 4 The test operation should last about 30 minutes Manual control o AUTO COOL button
6. eter indicates 0 instead of minus After the evacuation is complete fully close the handle Lo of the manifold valve and stop the operation of the vacuum pump e Make evacuation for 15 minutes and more and check that the compound meter indicates 76cmHg 1 0x10 Pa 6 Turn the stem of the packed valve B about 45 counter clockwise for 6 7 seconds after the gas coming out then tighten the flare nut again Make sure the pressure display in the pressure indicator is a little higher than the atmosphere pressure 7 Remove the charge hose from the Low pressure charge hose 8 Fully open the packed valve stems B and A 9 Securely tighten the cap of the packed valve Manifold valve Compound meter Pressure gauge 76cmHg lt X Handle Lo Charge hose gt Charge hose Vacuum pump Packed valve 3 Safety andleakage check Indoor unit check point 1 Soap water method Apply a soap water or a liquid neutral detergent on the indoor unit connections and outdoor unit connections by a soft brush to check for leakage of the connecting points of the piping If bubbles come out it indicates that the pipes have leakage 2 Leak detector Use the leak detector to check for leakage CAUTION A Lo packed valve B Hi packed valve C and D are ends of indoor unit connection check point 4 Testrunning Perform test operation after completing gas leak check at the flare nut connections and electrical safety ch
7. gf cm 479kgf cm CONNECT THE CABLE TO THE OUTDOOR UNIT Remove the electrical control board cover from the outdoor unit by loosening the screw Connect the connective cables to the terminals as identified with their respective matched numbers on the terminal block of indoor and outdoor units Secure the cable onto the control board with the cord clamp To prevent the ingress of water form a loop of the connective cable as illustrated in the installation diagram of indoor and outdoor units Insulate unused cords conductors with PVC tape Process them so they do not touch any electrical or metal parts Terminal block of outdoor unit ee 2 N l e o fe MURNI S L ai BESANT To indoor unit Power supply Model B 1 S i l To indoor unit Power supply Model A AIR PURGING AND TEST OPERATION Connective pipe length will affect the capacity and energy efficiency of the unit The nominal efficiency is tested basing on the pipe length of 5 meters NOTE 1 Airpurging The indoor unit and tubing between the indoor and outdoor unit must be leak tested and evacuated to remove any noncondensables and moisture from the system Check that each tube both liquid and gas side tubes between the indoor and outdoor units have been properly connected and all wiring for the test run ha
8. hioning material between the indoor unit and the wall Get it out after finish piping 4 Press the lower left and right side of the unit against the installation plate until hooks engages with the their slots Drain hose Upper Hook Cushioning material Lower Hook p OUTDOOR INSALLATION PRECAUTION e Install the outdoor unit on a rigid base to prevent increasing noise level and vibration Determine the air outlet direction where the discharged air is not blocked in the case that the installation place is exposed to strong wind such as a seaside make sure the fan operating properly by putting the unit lengthwise along the wall or using a dust or shield plates Specially in windy area install the unit to prevent the admission of wind If need suspending installation the installation bracket should accord with technique requirement in the installation bracket diagram The installation wall should be solid brick concrete or the same intensity construction or actions to reinforce damping supporting should be taken The connection between bracket and wall bracket and the air conditioner should be firm stable and reliable Be sure there is no obstacle which block radiating air Incorrect Correct Barrier JS x Strong wind wind gt a DRAIN JOINT INSTALLATION NOTE The drain joint is slightly different according to the different out
9. ion instructions If drainage is not perfect water may enter the room and damage the furniture SELECT THE BEST LOCATION Indoor unit There should not be any heat source or stream near the unit There should not be any obstacles blocking the air circulation e A place where air circulation in the room is good e A place where drainage can be easily done e A place where noise prevention is taken into consideration Do not install the unit near the door way Ensure the spaces indicated by arrows from the 2 3m or more wall ceiling fence or other obstacles There should not be any direct sunlight If unavoidable sunlight prevention should be taken into consideration Outdoor unit f an awning is built over the unit to prevent direct sunsight or rain be careful that heat radiation from the condenser is not obstructed There should not be any animal or plant which could be affected by hot air discharged e Keep the spaces indicated by arrow from wall ceiling fence or other obstacles e Do not place any obstacles which may cause a short circuit of the discharged air Settlementofoutdoorunit Anchor the outdoor unit with a bolt and nut 10 or 8 tightly and horizontally on a concrete or rigid mount NOTE The outdoor unit you purchase may be like one of the following Install the outdoor unit according to the dimension as indicated in the table below l N D O O R U N T Minimumcross se
10. models A 940 B 275 C 110 D 100 2 DRILL A HOLE IN THE WALL Determine hole positions according to left and right side of the installation plate The hole center is obtained by measuring the distance as shown in the diagram above Dirll the piping plate hole with 65mm hole core drill Drill the piping hole at either the right or the left and the hole should be slightly slanted to the outdoor side Always take steps to protect the pipe when drilling metal 7 When carrying out piping connection take care not to let air substances other than the specified grid metal plate or the like refrigerant go into refrigeration cycle Otherwise it will cause lower capacity abnormal high pressure in the refrigeration cycle explosion and injury 8 Do not modify the length of the power supply cord or use of extension cord and do not share the single outlet with other electrical appliances Otherwise it will cause fire or electrical shock CONNECT THE CABLE TO THE INDOOR UNIT Electrical work Electric safety regulations for the initial Installation If there is serious safety problem about the power supply the technicians should refuse to install the air conditioner and explain to the client until the problem is solved Power voltage should be in the range of 90 110 of rated voltage The surge protector and main power switch with a 1 5 times capacity of Max Current of the unit should be installed in power circui
11. reshening filter used to install on Air filter Drainage _y 1 Run the drain hose sloping downward j Do not install the drain hose as illustrated in wrong figures f 2 When connecting extension drain hose Da not putthe end of insulate the connecting part of extension Do not block water flow by a rise drain hose into water drain hose with a shield pipe do not let the drain hose slack Wrong NOTE Except the above parts provided the other parts needed during installation you must purchase Connective pipe installation 1 For the left hand and right hand piping remove the pipe cover from the side panel 2 For the right back and left back piping install the piping as shown NOTE Both sides drainage structure is Move and tape the drain hose with piping in a position as mentioned in Fig Below Cover for the left piping standard For both sides drainage structure Cora torne it can be choosen for right left or both sides P drainage connection If choosing both sides SS drainage connection another proper drain hose is needed as there is only one drain hose offered by factory If choosing one side drainage connection make sure the drain hole on the other side is well plugged For 9k 12k models if choosing left hand or left back piping please choosing left side drainage connection The connection of the
12. revent it from the vibration Installation Plate Mounting 120mm or more to wall 1 Fit the installation plate horizontally 2 on structural parts of the wall with o i 3 2 Left rear side spaces around the installation plate refrigerant i If the wall is made of brick concrete pipe hole 65 Indoor unit outline 120mm or more to wall co Right rear side refrigerant pipe or the like drill five or eight 5mm diameter holes in the wall Insert Clip anchor for appropriate mounting screws Fit the installation plate on the wall with five or eight type A screws NOTE 120mm or i Mount the Installation Plate and drill mere es holes in the wall according to the i wall structure and corresponding Left rear side x 4 i refrigerant i mounting points on the installation pipe hole 65 hole 65 Indoor unit outline 120mm or more to wall a 2 Right rear side refrigerant pipe plate The installation plate provided hole 65 with the machine differ from appliance 12000Btu h models A 800 B 275 C 100 D 95 to appliance Dimensions are in mm unless otherwise stated Correct orientation 120mmor of Installation Plate more to wall t 150mm or more to ceiling S Left rear side Indoor unit outline 120mm or more to wall co Right rear side refrigerant pipe Alb refrigerant i f E a pipe hole p 65 foot ermm J x x hole 65 18000Btu h
13. s been completed Pipe length and refrigerant amount Connective pipe length Air purging method Additional amount of refrigerant to be charged Less than 5m Use vacuum pump Liquid side 6 35mm Liquid side 6 9 52mm R22 Pipe length 5 x30g m R22 Pipe length 5 x60g m R410A Pipe length 5 x20g m R410A Pipe length 5 x40g m More than 5m Use vacuum pump For the R410A refrigerant model make sure the refrigerant added into air conditioner is liquid form in any cases When relocating the unit to another place using vacuum pump to perform evacuation CAUTION Open the valve stem until it hits against the stopper Do not try to open it further Securely tighten the valve stem cap with a spanner or the like Valve stem cap tightening torque See Tightening torque table Refrigerant Flare nut Outdoor cin unit A Gasside c iquid side p Packed valve Flare nut 2 Whenusingthe Vacuum Pump 1 Completely tighten the flare nuts A B C D connect the manifold valve charge hose to a charge port of the packed valve on the gas pipe side Connect the charge hose connection to the vacuum pump Fully open the handle Lo of the manifold valve Operate the vacuum pump to evacuate After starting evacuation slightly loose the flare nut of the packed valve on the gas pipe side and check that the air is entering Operation noise of the vacuum pump changes and a compound m
14. t Ensure the air conditioner is grounded well The appliance shall be installed in accordance with national wiring regulations Do not operate your air conditioner in a wet room such as a bathroom or laundry room An all pole disconnection device which has at least 3mm clearances in all poles and have a leakage current that may exceed 10mA the residual current device RCD having a rated residual operating current not exceeding 30mA and disconnection must be incorporated in the fixed wiring in accordance with the wiring rules 6 For the unit adopts auxiliary electric heater keep at least 1 meter away from the nearest combustible materials 7 According to the attached Electrical Connection Diagram located on the panel of the indoor amp outdoor unit to connect the wire 8 All wiring must comply with local and national electrical codes and be installed by qualified and skilled electricians 9 An individual branch circuit and single receptacle used only for this air conditioner must be available See the following table for suggested wire sizes and fuse specifications caution 1 This equipment must be grounded and installed with ground leakage current breaker It may cause electrical shock if grounding is not perfect 2 Do not install the unit at place where leakage of flammable gas may occur In case gas leaks and accumulates at surrounding of the unit it may cause fire 3 Carry out drainage piping as mentioned in installat
15. th the cord clamp NOTE If used as MONO unit for the standby control needs the cross section area of cable connected to L 1 W 1 1 L 2 N must be sufficient for the maximum system current The maximum system current is equal to the sum of indoor unit and outdoor unit rated current If used as MULTI unit L 1 W on the terminal block does not need to be connected Front Panel Terminal block of indoor unit Electronic box 8 Q eT QQ EAIA L1 1 8 S t W 10208 S L TT 8 Q TT Outdoorunitdimension Mountingdimensions mm WxHxD A mm B mm 700x540x240 458 250 685x430x260 460 276 780x540x250 549 276 760x590x285 530 290 n a z 845x700x320 560 335 asi 810x558x310 325 maT 670x540x265 276 W Air outlet XL ACCESSORIES umber NameofAccessories Qty 1 Installation Plate 1 Clip Anchor 5 8 dependingonmodels Self tapping Screw A ST3 9x25 5 8 dependingonmodels Seal For cooling amp heating models only 1 Drain Joint For cooling amp heating models only 1 06 35 Connecting Liquidside 09 52 Parts you must purchase The pipe pipe size differ from appliance to appliance Assembly 9 52 Consult the technician for the proper Gasside 12 7 size 16 To outdoor unit To outdoor unit Model A Model B Remote controller Self tapping Screw B ST2 9x10 optional Remote controller holder parts Air f
16. y A CAUTION This symbol indicates the possibility of injury or damage to property WARNING 1 Install according to this installation instructions strictly If installation is defective it will cause water leakage electrical shock or fire 2 Use the included accessories parts and specified parts for installation otherwise it will cause the set to fall water leakage electrical shock or fire 3 Install at a strong and firm location which is able to withstand the set s weight If the strength is not enough or installation is not properly done the set will drop and cause injury 4 For electrical work follow the local national wiring standard regulation and this installation instructions An independent circuit and single outlet must be used If electrical circuit capacity is not enough or defect found in electrical work it will cause electrical shock or fire 5 Use the specified cable and connect tightly and clamp the cable so that no external force will be acted on the terminal If connection or fixing is not perfect it will cause heat up or fire at the connection 6 Wiring routing must be properly arranged so that control board cover is fixed properly If control board cover is not fixed perfectly it will overheat at connection point of terminal fire or electrical shock INSTALLATION PLATE MOUNTING NOTE The mounting wall is strong and solid t 150mm or more to ceiling enough to p