Home
        PROTRON STAR User Manual
         Contents
1.   Elation Professional     www elationlighting com   Protron Star    Instruction Manual Page 2    Unpacking  Thank you for purchasing the Protron Star    by Elation  Professional    Every Protron Star    has been thoroughly tested and has  been shipped in perfect operating condition  Carefully check the ship   ping carton for damage that may have occurred during shipping  If the  carton appears to be damaged  carefully inspect your unit for damage  and be sure all accessories necessary to operate the unit have arrived  intact  In the event damage has been found or parts are missing  please  contact our customer support number for further instructions  Please  do not return this unit to your dealer without first contacting customer  support at the number listed below     Introduction  To optimize the performance of this product  please  read these operating instructions carefully to familiarize yourself with  the basic operations of this unit  The Protron Star    is a 750 watt  strobe  that has a flash rate range of 1 to 15 flashes per second  Up to  16 units may be linked together and controlled by single controller  The  units    intensity  flash rate  and flash duration can be manually adjusted  using the dipswitches  For remote control operation an optional remote  control is available from Elation Professional       Customer Support  Elation Professional   provides a customer sup   port line  to provide set up help and to answer any question should you  encounter problems
2.  SOUND    REMOTE  CONTROL    INPUT    POWER    INPUT  OUTPUT    SOUND    REMOTE  CONTROL  INPUT    POWER    INPUT  OUTPUT    SOUND    REMOTE  CONTROL  INPUT    POWER    INPUT  OUTPUT    DMX512    DMX  DMX  COMMON    1    2    3    Termination reduces signal errors and  avoids signal transmission problems  and interference  It is always advisable  to connect a DMX terminal   Resistance  120 Ohm 1 4 W  between PIN 2  DMX    and PIN 3  DMX    of the last fixture     1    2    3    1    2    3    DMX      DMX      COMMON    DMX512 OUT    3 PIN XLR    Figure 4    5 Pin XLR DMX Connectors  Some manufactures use 5 pin XLR  connectors for DATA transmission in place of 3 pin  5 pin XLR    xtures  may be implemented in a 3 pin XLR DMX line  When inserting stan   dard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be  used  these adaptors are readily available at most electric stores  The  chart below details a proper cable conversion     Conductor  5 Pin XLR Male  In   3 Pin XLR Female  Out     Pin 1    Pin 5   Do Not Use    Pin 4   Do Not Use    Pin 3    Pin 2    Pin 1    Pin 3    Pin 2    Not Used    Not Used    Data True    signal     Data Compliment    signal     Ground Shield    3 Pin XLR to 5 Pin XLR Conversion    Protron Star     DMX Set Up      Elation Professional     www elationlighting com   Protron Star    Instruction Manual Page 7    Elation Professional     www elationlighting com   Protron Star    Instruction Manual Page 8    Protron Star    Operating Instr
3.  during your set up or initial operation  You may  also visit us on the web at www elationlighting com for any comments  or suggestions  For service related issue please contact Elation Pro   fessional    Service Hours are Monday through Friday 9 00 a m  to 5 00  p m  Pacific Standard Time   Voice    323  582 3322  Fax    323  582 3108  E mail   support elationlighting com    Warning  To prevent or reduce the risk of electrical shock or fire  do  not expose this unit to rain or moisture     Caution  There are no user serviceable parts inside this unit  Do not  attempt any repairs yourself  doing so will void your manufactures war   ranty     Please do not discard the shipping carton in the trash  Please recycle  when ever possible     Protron Star     Introduction    User Instructions    3 04      Elation Professional    4295 Charter Street    Los Angeles Ca  90058  www elationlighting com    Protron Star     Warranty Registration      Elation Professional     www elationlighting com   Protron Star    Instruction Manual Page 3    The Protron Start    carries a two year  730 days  limited warranty   Please fill out the enclosed warranty card to validate your purchase   All returned service items whether under warranty or not  must be  freight pre paid and accompany a return authorization  R A   number   The R A  number must be clearly written on the outside of the return  package  A brief description of the problem as well as the R A  num   ber must also be written down on a p
4.  on  pinched by items placed upon or against them       Cleaning  The fixture should be cleaned only as recommended by  the manufacturer  See page 6 for cleaning details       Heat  The appliance should be situated away from heat sources  such as radiators  heat registers  stoves  or other appliances   including amplifiers  that produce heat       The fixture should be serviced by qualified service personnel when   A   The power supply cord or the plug has been damaged   B  Objects have fallen  or liquid has been spilled into the unit   C   The unit has been exposed to rain or water   D  The unit does not appear to operate normally or exhibits a  marked change in performance     Protron Star     DMX Set Up      Elation Professional     www elationlighting com   Protron Star    Instruction Manual Page 5    Power Supply  Before plugging your unit in  be sure the source volt   age in your area matches the required voltage for your Elation   Protron  Star     The Elation   Protron Star    is 120v only  Because line voltage  may vary from venue to venue  you should be sure your unit voltages  matches the wall outlet voltage before attempting to operate you    x   ture     DMX 512  DMX is short for Digital Multiplex  This is a universal pro   tocol used as a form of communication between intelligent fixtures  and controllers  A DMX controller sends DMX data instructions from  the controller to the fixture  DMX data is sent as serial data that trav   els from fixture to fixture via 
5. allow the shield  conductor to come in contact with the XLR   s outer casing  Grounding  the shield could cause a short circuit and erratic behavior     DMX512 IN  3 PIN XLR    SOUND    REMOTE  CONTROL    INPUT    POWER    INPUT  OUTPUT    SOUND    REMOTE  CONTROL  INPUT    POWER    INPUT  OUTPUT    SOUND    REMOTE  CONTROL  INPUT    POWER    INPUT  OUTPUT    DMX512    DMX  DMX  COMMON    1    2    3    Termination reduces signal errors and  avoids signal transmission problems  and interference  It is always advisable  to connect a DMX terminal   Resistance  120 Ohm 1 4 W  between PIN 2  DMX    and PIN 3  DMX    of the last fixture     1    2    3    1    2    3    DMX      DMX      COMMON    DMX512 OUT    3 PIN XLR    Figure 2    Figure 1    Figure 3    1 Ground  1 Ground    XLR Male Socket  XLR Pin Con   guration    3 Hot    2 Cold  2 Cold    3 Hot    XLR Female Socket    Pin 3   Data True  positive     Pin 2   Data Compliment  negative     Pin 1   Ground    Special Note  Line Termination  When longer runs of cable are  used  you may need to use a terminator on the last unit to avoid erratic  behavior  A terminator is a 90 120 ohm 1 4 watt resistor which is con   nected between pins 2 and 3 of a male XLR connector  DATA   and  DATA     This unit is inserted in the female XLR socket of the last unit  in your daisy chain to terminate the line  Using a cable terminator  ADJ  part number Z DMX T  will decrease the possibilities of erratic behav   ior     DMX512 IN  3 PIN XLR   
6. cts without any obligation to include these changes in any products  theretofore manufactured     F  No warranty  whether expressed or implied  is given or made with respect to any acces   sory supplied with products described above  Except to the extent prohibited by applicable  law  all implied warranties made by Elation Professional   in connection with this product   including warranties of merchantability or    tness  are limited in duration to the warranty  period set forth above  And no warranties  whether expressed or implied  including warran   ties of merchantability or    tness  shall apply to this product after said period has expired   The consumer   s and or Dealer   s sole remedy shall be such repair or replacement as is  expressly provided above  and under no circumstances shall Elation Professional   be liable  for any loss or damage  direct or consequential  arising out of the use of  or inability to use   this product   G  This warranty is the only written warranty applicable to Elation Professional   Products  and supersedes all prior warranties and written descriptions of warranty terms and condi   tions heretofore published     Protron Star     Warranty      Elation Professional     www elationlighting com   Protron Star    Instruction Manual Page 13    Elation Professional     www elationlighting com   Protron Star    Instruction Manual Page 14    Protron Star     Notes      Elation Professional    Elation World Headquarters   4295 Charter Street Los An
7. geles  CA 90058 USA  Tel  323 582 3322   Fax  323 582 3108  Web  www elationlighting com   E mail  info elationlighting com    Model  Protron Star     Voltage    120v 60Hz    Lamp   ZB 300 750w Strobe lamp    Fuse   20A 120v    Dimensions   10     L  x 14 5     W  x 9 2     H   Weight   14 Lbs     Duty Cycle   15 minutes on off  Ventilation   Air Cooled  Warranty   2 Year  730 Days      Voltage is preset at the factory and can not be changed by the user     Please Note  Speci   cations and improvements in the design  of this unit and this manual are subject to change without any  prior written notice     Protron Star     Specifications      Elation Professional     www elationlighting com   Protron Star    Instruction Manual Page 15    
8. h  the product  If any accessories are shipped with the product  Elation Professional   shall  have no liability whatsoever for loss of or damage to any such accessories  nor for the safe  return thereof     C  This warranty is void if the serial number has been altered or removed  if the product is  modi   ed in any manner which Elation Professional   concludes  after inspection  affects the  reliability of the product  if the product has been repaired or serviced by anyone other than  the Elation Professional   factory unless prior written authorization was issued to purchaser  by Elation Professional    if the product is damaged because not properly maintained as set  forth in the instruction manual     D  This is not a service contract  and this warranty does not include maintenance  cleaning  or periodic check up  During the period speci   ed above  Elation Professional   will replace  defective parts at its expense  and will absorb all expenses for warranty service and repair  labor by reason of defects in material or workmanship  The sole responsibility of Elation  Professional   under this warranty shall be limited to the repair of the product  or replace   ment thereof  including parts  at the sole discretion of Elation Professional    All products  covered by this warranty were manufactured after January 1  1990  and bear identifying  marks to that effect     E  Elation Professional   reserves the right to make changes in design and or improve   ments upon its produ
9. iece of paper and included in  the shipping container  If the unit is under warranty  you must provide  a copy of your proof of purchase invoice  You may obtain a R A  num   ber by contacting customer support at  323  582 3322     Protron Star     Cleaning Instructions    Due to fog residue  smoke  and dust cleaning the fixture should be  carried out periodically to optimize light output   1  Use normal glass cleaner and a soft cloth to wipe down the out   side casing every 20 days   2  Use normal glass cleaner with a soft cloth to wipe down the inside  reflector and lens every 30 60 days   3  Always be sure to dry all parts completely before plugging the  unit back in   4  Frequent cleaning the unit will extend lamp life and ensure the fix   tures reliability   Cleaning frequency depends on the environment in which the fixture  operates  I e  smoke  fog residue  dust  dew   In heavy use we rec   ommend cleaning on a monthly basis  Periodic cleaning will ensure  longevity  and crisp beam output     Protron Star     Features         Bright 750 Watt Lamp       Adjustable Flash Rate  Intenstiy Rate  and Flash Duration       Flash Rate range of 1 to 15 Flashes per Second       Thermostat Protection       Large coverage area       Easy lamp Replacement       Link Up To 16 Units Together      Built In Adjustable Hanging Yoke      Elation Professional     www elationlighting com   Protron Star    Instruction Manual Page 4    Protron Star     Safety Warnings    Safety Issues  This un
10. it may blow a fuse if the maximum allotted load  of 20 amps is reached  If the fuse needs replacement  always replace  the fuse with same exact type that was remove  unless otherwise  instructed by an authorized Elation Professional   service technician   Use of a different type fuse from that which is recommended may  cause fire or electric shock and will void the manufactures warranty         To reduce the risk of electrical shock or    re  do not expose this unit  rain or moisture       Do not spill water or other liquids into or on to your unit       Do not attempt to remove or break off the ground prong from the  electrical cord  This prong is used to reduce the risk of electrical  shock and    re in case of an internal short  Do not attempt to oper   ate this unit if the power cord has been frayed or broken       Disconnect from main power before making any type of connection       Do not remove the cover under any conditions  There are no user  serviceable parts inside       Always be sure to mount this unit in an area that will allow proper  ventilation  Allow about 6     15cm  between this device and a wall       Do not attempt to operate this unit  if it becomes damaged       This unit is intended for indoor use only  use of this product out   doors voids all warranties       During long periods of non use  disconnect the unit   s main power       Always mount this unit in safe and stable matter       Power cords should be routed so they are not likely to be walked 
11. llow the DMX address chart on page 12     Protron Star    Operating Instructions    Channel  Value  Function    1 0   255 FLASH SPEED    2 0   255 FLASH DIMMING    3 0   255 FLASH DURATION    Protron Star    DMX Traits    Protron Star    Fuse and Lamp Replacement      Elation Professional     www elationlighting com   Protron Star    Instruction Manual Page 10    Warning  Allow the lamp to discharge all current  Allow the  unit 24hrs  to discharge before changeing the lamp  Stored  current can cause a very severe shock     Caution  Always replace with the exact same type lamp and fuse   unless otherwise specified by an authorized Elation Professional    technician  Replace with anything other than the specified part can  damage your unit and will void your manufactures warranty     Warning  If after you have replaced the lamp or fuse and you contin   ue to blow either one  STOP using the unit  Contact customer support  for further instructions  you may have to return the unit for servicing   Continuing to use the unit may cause serious damage     Fuse Replacement  Disconnect the unit   s main power supply   Insert a standard flat head screw driver in to the fuse holder hous   ing  located on the rear of the unit   Turn the screwdriver in a coun   ter clockwise direction to remove the fuse holder  Remove the old  fuse and discard it  replace the fuse with the same type  Insert the  fuse holder back into it   s housing and turn in a clockwise direction to  secure the holder in 
12. n    pos   tion to activate  Dipswitch Traits  Manual Mode    To activate manual mode you must have dipswitch  9 in the    on     postion   1  Dipswitches 1 3 control the speed of the strobe  Dipswitch  1  being the slowest strobe  and dipswitch  3 being the fastest  strobe   2  Dipswitches 4 6 control the brightness of the strobe  Dipswitch  4  being the dimmest  dipswitch  6 being the brightest   3  Dipswitches 7 8 control the duration of the strobe  Dipswitch  7  the longest duration between strobes  and dipswitch  8 the short   est duration between strobes       Elation Professional     www elationlighting com   Protron Star    Instruction Manual Page 9    Universal DMX Control  This mode allows you to use a universal  DMX 512 controller such as the Elation   DMX Operator    or Show  Designer      1  To control your fixture in DMX mode  follow the set up procedures  on pages 5 6 as well as the set up procedures included with  your DMX controller   2  For longer cable runs  more than a 100 feet  use a terminator on  the last fixture   3  Assign your desired address to the unit  and    flip    dipswitch  10  to the    on    postion   4  The Protron Star    uses three DMX channels  Use your DMX con   troller to activate the various built in patterns  See the bottom of  this page for the DMX traits   5  For help operating in DMX mode consult the manual included  with your DMX controller   NOTE  If running in Master Slave address configuration while using a  DMX controller  fo
13. nlighting com   Protron Star    Instruction Manual Page 6    sound activation     Assigning DMX Address  Each dipswitch has a preset value  A spe   cific DMX address is set by combining the dipswitches that sum your  desired value  For example  To achieve a DMX address of 7  combine  dipswitches 1  2  and 3  Since dipswitch 1 has a value of 1  dipswitch  2 has a value of 2  and dipswitch 3 has a value of 4  the combination  of the three create a DMX value of 7   See example below      Set DMX address 1   Set DMX address 7   Dip switches   1   1  Dip switches   1   1  2   2  3   4    7    Data Cable  DMX Cable  Requirements  For DMX  and Master Slave Operation   The Protron Star     can be controlled via DMX 512 protocol  The Pro   tron Star    is a three channel DMX unit  The DMX  address is set on the side panel of the Protron  Star    Your unit and your DMX controller require  a standard 3 pin XLR connector for data input and  data output  Figure 1   If you are making your own  cables  be sure to use standard two conductor shielded cable  This  cable may be purchased at almost all pro sound and lighting stores    Your cables should be made with a male and female XLR connector on  either end of the cable  Also remember that DMX cable must be daisy  chained and can not be split     Notice  Be sure to follow    gures two and three when making your own  cables  Do not use the ground lug on the XLR connector  Do not con   nect the cable   s shield conductor to the ground lug or 
14. place     Lamp Replacement  Caution  Never open the unit when in use   Always disconnect the main power and allow the fixture ample time  to cool before attempting to replace the lamp  Lamp replacement has  been made simple by incorporating a remove tray that is retained by a  single thumb screws  Again  please remember to always replace with  the exact same type lamp   1  Be sure to follow the proper procedures when handling halogen  lamps  Never touch the new lamp with your bare fingers   2  Unscrew the two thumb screws located on the glass cover in the  top corners of the unit     Halogen Lamp Warning  This fixture is fitted with  halogen lamps which are highly susceptible to dam   age if improperly handled  Never touch the lamps  with your bare fingers as the oil from your hands will  shorten lamp life  Also  never move the fixture until  the lamps have had ample time to cool  Remember   lamps are not covered under warranty conditions     This chart list the DMX dipswitch setting for DMX address 1 through  511  Follow the instructions below to configure fixture dipswitches  with your desired DMX address     Protron Star    DMX Address Chart      Elation Professional     www elationlighting com   Protron Star    Instruction Manual Page 12    3  Located on each side of the lamp are white ceramic wire con   nection blocks   4  The ceramic block on the left side has two lamp wires connected  to it  they are secured by one phillips screw each  On the right  side only one lamp 
15. the DATA    IN    and DATA    OUT    XLR ter   minals located on all DMX fixtures  most controllers only have a DATA     OUT    terminal      DMX Linking  DMX is a language allowing all makes and models of  different manufactures to be linked together and operate from a sin   gle controller  as long as all    xtures and the controller are DMX com   pliant  To ensure proper DMX data transmission  when using several  DMX fixtures try to use the shortest cable path possible  The order  in which fixtures are connected in a DMX line does not influence the  DMX addressing  For example  a fixture assigned a DMX address of 1  may be placed anywhere in a DMX line  at the beginning  at the end   or anywhere in the middle  When a fixture is assigned a DMX address  of 1  the DMX controller knows to send DATA assigned to address 1  to that unit  no matter where it is located in the DMX chain     Dipswitches in DMX mode  This unit uses dipswitches to assign a  DMX address  Each dipswitch represents a binary value   Dipswitch 1 address equals 1  Dipswitch 2 address equals 2  Dipswitch 3 address equals 4  Dipswitch 4 address equals 8  Dipswitch 5 address equals 16  Dipswitch 6 address equals 32  Dipswitch 7 address equals 64  Dipswitch 8 address equals 128  Dipswitch 9 address equals 256  Dipswitch 10   Some units omit dipswitch 10  When a unit does  include dipswitch  10  it is usually used for special functions such as    Protron Star     DMX Set Up      Elation Professional     www elatio
16. uctions    Power Supply  This unit is available only in 120v  Before plugging  your unit in be sure the source voltage in your area matches the  required voltage for your Elation   Protron Star      General Operation  This fixture is designed to operate as a stand  alone  sound active unit  or in a Master Slave configuration  It can  also operate via DMX controller  The Protron Star    is ready to be  plugged in out of the box   Duty Cycle   Because the Protron Star    can be used for continuous output  ie  while simulating lightning   it can build up intense heat  Due to the  build up of intense heat the unit should not run for 15 minutes con   tinuously  After 15 minutes of continuous use  allow the unit to cool  for about fifteen minutes  this will greatly increase the lamp life and  insure product longevity   Operating Modes   Stand Alone   In stand alone the unit will function as a normal strobe light  Rate   speed   intensity  brightness   and duration  length between flashes   are set directly on the unit  Note that these settings are made using  the dipswitches on the back of the unit  Once the settings are made  they can only be changed by physically adjusting the dipswitches on  the unit  Be aware of this if you plan on installing your strobe in a per   manent application  if your are not satisfied with your settings you will  have to physically remove the unit and adjust the dipswitches  Please  see the dipswitch traits below     Flip    the dipswitches to the    o
17. wire is connected to a ceramic block     5  NOTICE  When you disconnect the lamp wires to replace the  lamp  you will have to remember which wire went where  They  must be connected the same   6  Replace the lamp with an exact match  Connect the three wires to  the ceramic blocks as they were when you disconnected them   7  Reassemble in reverse order     Protron Star    Fuse and Lamp Replacement      Elation Professional     www elationlighting com   Protron Star    Instruction Manual Page 11    2 YEAR LIMITED WARRANTY    A  Elation Professional   hereby warrants  to the original purchaser  Elation Professional    products to be free of manufacturing defects in material and workmanship for a period of  two years  730 days  from the date of purchase  This warranty shall be valid only if the prod   uct is purchased within the United States of America  including possessions and territories   It is the owner   s responsibility to establish the date and place of purchase by acceptable  evidence  at the time service is sought     B  For warranty service  send the product only to the Elation Professional   factory  All  shipping charges must be pre paid  If the requested repairs or service  including parts  replacement  are within the terms of this warranty  Elation Professional   will pay return ship   ping charges only to a designated point within the United States  If the entire instrument  is sent  it must be shipped in its original package  No accessories should be shipped wit
    