NESS D8 install manual

image

Contents

1. actory Defaults Delete all codes Set Installer code DEFAULT 000000
2. Zone LED 5 ON selects a FORCED OPENING REPORT after ALARM Zone LED 5 OFFdisables a FORCED OPENING REPORT after ALARM An Opening Report and Restore Report are sent when a Zone or Miscellaneous Alarm has been reset by a Valid FORCED OPENING REPORT CANCEL User Code or Radio Key NOTE AREA OPENING or CLOSING reports do not have to be selected for this option to operate This message may be an indication to the Central Station that a user has dis armed the system Factory Pre set Off No forced opening PROGRAMMING OPTION DESCRIPTIONS SS_L_L_L_aa gt SS UUU P89E 1E ENABLE TEST CALLS Zone LED 1 ON selects Automatic Test Calls Zone LED 1 OFF disables Automatic Test Calls Factory Pre set Off No Test Calls P89E 2E Zone LED 2 ON selects a Mains Fail after 1 Hour if the Mains has been off continuously for that time DELAY MAINS FAIL REPORT BY 1 HOUR Zone LED 2 OFF disables a delay and sends the M ain Fail report instantly Factory Pre set On Delay M ains Fail Reports P89E 4E Zone LED 4ON selects swinger shutdown Zone LED 4 OFF disables swinger shutdown This option limits the number of times a single zone alarm will dial the central station when used in conjunction when option P78E Report Multiple events has been selected for that zone This option eliminates the multiple alarms sent to ENABLE SWINGER SHUTDOWN the central station when a device goes into run away mode ie becomes faulty an
3. ala ET w an Ness D 8 Remote Keypad en 14 D A pat P __ lS lpata ox D en Lu HE coM com Dx e ax PH N Rasat B a Rasat a EA A o ead eevee hr a wire connection A maximum of 3 The maximum cable run is 100M using 14 20mm cable Ifthe cable 1s shared then divide za STR B 100M by the number of keypads to ba connected eg 2 keypads on the cable reduces the tmexdmum run to SOM SR P INSTALLATION CONTROLS AND INDICATIONS Ness D 8 Keypad The Ness D 8 LED Keypad consists of a Backlit 18 button rubber keypad 19 status lights and an internal beeper contained in a modern white plastic housing The hous ing has a hinged front lid to protect the rubber buttons when not in use All the electronics are contained ona single circuit board inside the housing Audible Indications Every time a button is pressed the panel responds with a very brief beep in acknowledgment d The beeper is also used to indicate whether the entry was valid or invalid For example whenever the Enter button is pressed all the buttons pressed before it are checked to see whether they are valid If they are valid the response will be 3 short beeps ddd If they are invalid or incorrect the response will be 1 long beep and all previous keypresses they will be ignored d d At other times the beeper will indi
4. and the zone light will flash To program a Radio Reed switch to the D 8 have the battery connected with the magnet is a closed position eg sealed with the magnet next to the reed switch Move the magnet away from the reed switch and the Reedswitch will transmit several messages when the code is accepted 3 beeps are given and the zone light will flash NOTES 1 A RADIO DEVICE operates in parallel with the existing hard wired zone input Any device connected to the zone input both radio and hard wired when triggered will unseal the zone 2 Ifa radio device is used the zone input must be sealed with a 2 2K EOL Resistor 3 If Radio devices are used vibration sensor P30E zone LED on settings must be left at factory defaults 1 To learn a RADIO DEVICE prepare the device to transmit see above i Select the Zone Access Code P01 E to P08 E The response is 3 beeps If a code already exists then the appropriate zone led is displayed ii Press 1E to start the panel RADIO DEVICE learning iii Trigger the radio device to be learned See above A code already in use is rejected long beep unless already assigned to the current zone The response is 3 beeps when accepted and the appropriate zone light flashes A steady zone light indicates that the existing code for that zone has not changed 4 To clear a RADIO DEVICE i Select the Zone Access Code POLE to P08 E The response is 3 beeps ii Press OE to clear a
5. Input When P 60E 2E 3E ie Both options selected the Panel will cycle through all three operating modes on each shorting of the Zone 8 Input ARM ae MONITOR a DISARM P 60 E 4E This option when selected will lockout the Siren output and only allowing the Sirens to sound once if multiple Tamper Alarms occur The Siren outputs become active again once the Panel has been reset by the use of an Authorised Access Code SIREN LOCKOUT ON TAMPER To de select enter P 60E 4E Zone LED 4 will be on when this option is selected and offwhenitis disabled Factory Pre Set Tamper Lockout On ie Zone LED 4 ON PROGRAMMING OPTION DESCRIPTIONS P 60 E 5E A Duress Alarm can be activated by Adding a 5 6 8 or 9 digit before your Access code ie If your access code is 3622 then adding a 5 6 8 or 9 before the code eg code 93 6 2 2 will disarm the panel and generate a Duress alarm This option when selected will activate the Reset output whenever a Duress Code is used DURESS ALARM TO ACTIVATE RESET OUTPUT To Select this option Enter P60E5E Zone LED 5 will be on when this option is selected and off when itis disabled Factory Pre Set No Reset Output Selected on Duress Alarm ie Zone LED 5 Off P 60 E 6E If a Zone is unsealed at the end of Exit Time as set by P 28 E the Ness D 8 will provide a 2 Second Siren Burst and the Zone unsealed will be automatically excluded not cause a
6. Movement Detector Sample Reed Detector Sample Warning Detector Keypad Wiring Controls and Indications Keypad and Indications PROGRAMMING Access to Program M ode How to Program PROGRAMMING DESCRIPTIONS User Codes P11E P25 E Setting Entry Time 1 P26E Setting Entry Time 2 P27E Setting Exit Time P28E Setting reset Time P29E Siren Time P29E Vibration Sensitivity Zones P 30E P 38E Double Trigger Zones P 39E Zone Assignment Instant Zones P40E Entry Delay 1 Zones P41E Handover Zones P42E Entry Delay 2 Zones P43E Siren Lockout Zones P44E Area Operation Assigning Area 1 Zones P 45E Assigning Area 2 Zones P46E Assign User Codes to Area 1 P47E P48E Assign User Codes to Area 2 P49E P50E Selecting M onitor Zones P51E Selecting 24 Hour Zones P52E Selecting Day Zones P53E Input to Output M apping Selecting Reset Output Zones P54E Selecting Strobe Output Zones P55E Selecting Keypad Sonalert Output Zones P56E Selecting Siren Output Zones P57E 29 29 29 27 27 28 28 28 28 29 29 29 29 30 30 31 31 32 32 33 33 34 34 35 35 35 35 36 36 36 37 38 39 40 41 41 41 43 44 44 48 54 59 Selecting Zones to Auxiliary 1 Output P58E Selecting Zones to Auxiliary 2 Output P59E Miscellaneous Options Entry warning Beeps P60E 1E Keyswitch Operation P60E 2E 3E Siren Tamper Lockout P60E 4E Duress Alarm to activate Reset Ou
7. O P 3 Sonalert O P 4 Siren O P Zone Lights 1 4 will indicate what outputs are to be activated by a Enter Output required to activate on a Tamper Alarm then Press ENTER a 1 Reset O P 2 Strobe O P 3 Sonalert O P 4 Siren O P ddd P61E 5 E 8E SELECTING PANIC ALARMS TO ACTIVATE OUTPUTS This option selects which Outputs will be activated if a Panic Alarm occurs Options P 61E 5E to P 61E 8 E selects outputs to activate as follows To View what Outputs will activate on a Panic Alarm P 61E The Zone 5 8 LED s will light to indicate which of the 4 Options are set to activate on a Panic Alarm To De Select Outputs from activating on a Panic Alarm enter the option ie 5 to 8 then ENTER To select it P 61E5E Selects the Reset Output again enter the option then ENTER again P 61E 6E Selects the Strobe Output P 61E 7E Selects the Keypad Sonalert Output P 61E 8E Selects the Siren Output The Factory Pre Set ALL Outputs to Activate on Panic Alarm Zone Lights 5 to 8 On SUMMARY To VIEW what outputs will activate on a Panic Alarm ENTER P e E Enter Output required to activate on a Panic Alarm then Press ENTER Jd Zone Lights 5 8 will indicate what outputs are to be activated by a Panic Alarm Condition ddd 5 Reset O P 5 Reset O P 6 Strobe O P 6 Strobe O P 7 Sonalert O P 7 Sonalert O P 8 Siren O P 8 Siren O P PROGRAMMING OPTION DESCRIPTIONS P 62 E Options P 62 E 1 E
8. for the connection of a sealed lead acid rechargeable 12 Volt battery with a minimum rating of 3 2 Charge current is limited to 350mA The charge voltage is factory preset at 13 8 V and does notneed changing Note A 12 Voltsealed lead acid rechargeable battery must be connected for cor rect panel operation Observe correct Polarity when connecting the battery Ness Part Number for the 12 volt 6 5 Ah battery is BAT 210 Earth For maximum protection against damage caused by lightning strikes connect a good earth to this terminal Alternatively use the Earth lead from the plug pack Program Tamper Link J 1 This link is used to enter Program M ode on initial power up Keep the Link on these Pins except when entering Install Program M ode on Power up Note Leaving the Link off will cause a internal tamper alarm on exit from Program M ode INSTALLATION OUTPUTS The Ness D 8 control Panel contains the following outputs NOTES 1 Output Fusing Power outputs on the D 8 are protected by Automatic Resettable electronic fuses Resetting a fuse that has opened is automatic once the overload is removed 2 Battery Operation A properly charged battery MUST be installed to ensure the Siren Strobe and Reset outputs operate correctly 12 Volt Output A regulated 13 8 V dc output is available to power detec tors and ancillary equipment This output is available from two sets of terminals marked 12V and OV It also has a Re
9. ie P 62 E 5 E for Area Lor P 62E 6 E for Area 2 must be disabled To View which Shortcuts have been selected Enter P 62E Zone 1 to 6 LED s will light to indicate what options have their Shortcuts enabled Factory Pre Set Options 1 to 5 Shortcuts Enabled Option 6 Disabled Zone Lights 1 5 on 6 Off P62E7E If a zone is unsealed at the end of Exit Time and Auto Excluding of Zones is selected as per programming option P 60 E 6 E the system can supply a 2 second Siren Burst as a warning that a zone has been Automatically Excluded This option provides an means of disabling the 2 second Siren Warning when a Zone is Auto Excluded To View if the 2 Second Warning is enabled enter P 62E7E 2 SECOND SIREN ON AUTO EXCLUDES Zone 7 LED will indicate the selection of this option When lit it will indicate the 2 Second Warning and when not lit it will indicate no warning Factory Pre set 2 Second Warning Enabled ie Zone 7 LED On PROGRAMMING OPTION DESCRIPTIONS P62E8E EXIT TIME X 10 If you require a longer than normal exit time you can To View if the this option is selected Enter P62E8E select this option which will multiply your Exit Time as set by P 28 E by 10 Zone 8 LED will indicate the selection of this option When lit it will indicate the Exit Time will be increased by EG If the Exit Time P 28 E is set as 22 seconds and this 10 and when not lit it will indicate it is as set exactly to P 62E 8E opti
10. into two groups known as Area 1 and Area 2 The two both Areas must be Armed before those Zones are Areas can be assigned access codes so that a user may Armed Area operation only applies when they are in have access to either Area 1 Area 2 or both Areas the Armed state This means that Day 24 hour and This allows for partial Arming of the premises or protecting Monitor zones are independent of area operation two separate premises with one NESS D 8 Eg Petrol Refer Programming Options P45E P50E for assigning Station and Workshop House and Granny Flat etc zones and codes to Areas Any Zone may be allocated to any Area and zones may be NOTE If no Area operation is required assign all included in both Areas to make those zones Common Zones to Area 1 Only P 45 E ASSIGNING AREA 1 ZONES To Assign Zones to Area 1 Enter P 45 E Zone E Note To UN assign a zone from being an Area 1 Zone Example To set say Zone 1 2 3 4 and 6 to Area 1 use the same method as above to switch the Zone light Enter P45E1E2E3E4E6E off ie P 45 E 1 E Selects Zone 1 1 E again de selects the Zone Factory Pre set All Zones are set to be Area 1 All Zone lights on SUMMARY To VIEW the Zones Set as Area 1 Zones ENTER Enter Zone required to be set as Area 1 Zones then Press ENTER 280 SS ow ep PROGRAMMING OPTION DESCRIPTIONS P 46E ASSIGNING AREA 2 ZONES To Assign Zones to Area 2 enter P 46 E Zone E Note To UN assign a zone from being
11. of quality Electronic Security Products Ness Security Products Pty Ltd is a Quality Accredited Company to ISO 9001 The Ness D 8 alarm system has been designed to provide you the security professional with all your most requested features including ease of installation ease of programming and user friendly operation in a package which is functional and attractive The Ness D 8 has been designed and built at an affordable price without compromising quality or features The High Impact 3 mm polycarbonate housing equivalent to 1 2 mm mild steel not only offers strength but is aestheti cally pleasing and therefore easily marketable Both the main board and the lid are removable which allows you to easily install the system This manual will tell you all you need to know about installing and programming the Ness D 8 For information about operating instructions refer to the Ness D 8 User s Manual FEATURES Q 8 Fully programmable zones Comes complete with an AC plug pack and Q Contact ID Dialler Format supports a 12V DC 7 AH battery to maintain Q Ultra M odern and Impact resistant Housing systems security under all power Ness Audible Dialler Formats supply conditions Follow Me Audible Dialler Option Q Monitor Mode Home Mode Separate 24 Hour Tamper input Q Outputs are separately fused Q Single or Double Trigger Zones Q Day Mode and Door Chime feature Remote Backlit Keypads Max 3 Q Zone inputs can be split with t
12. set as an Handover Zone and Press ENTER Zones Currently set as Handover P Bo krse uy ea P 43 E ENTRY 2 DELAY ZONES After expiry of the Exit Time as set by P 28 E a delay 2 Example To set say Zone 3 to be a Delay 2 zone Enter Zone becoming unsecured will cause an alarm at the P43E3E end of the Entry 2 Time as set by P 27 E if the Panel Factory Pre set No Zones set to Delay 2 Timer has not been Disarmed No Zone lights off SUMMARY To VIEW the Zones Set as Entry 2 Zones ENTER Enter Zone required to be set as an Entry 2 Zone and Press ENTER Zones Currently set as Entry 2 Pe EE Eee y E ow PROGRAMMING OPTION DESCRIPTIONS P 44E RESET LOCKOUT ZONES All 8 Zones can be programmed to lockout ie cause the Example To set say Zone 1 and Zone 2 to lockout Enter Reset Ouput to sound only once whilst the panel is armed P44E1E2E The Reset is locked out for that zone until the panel has been reset by entering a valid code Factory Pre set ALL Zones set to FULL LOCKOUT NOTE Only the Zone that caused an alarm will be locked All Zone lights on out The siren output will always lockout The resetting output will re trigger if selected OFF SUMMARY To VIEW the Zones Set for Reset Lockout Zones ENTER Enter Zone required to be set to Lockout Reset after alarming then Press ENTER FREE 88 The NESS D 8 Control Panel allows the 8 Zones to be split Area Zones If Zones are allocated to both Areas then
13. will respond with 3 Beeps ddd and the Program light will start to flash You are now in Installer Program M ode All programming options can be programmed from this programming mode Note Replace the Link once the Ness D 8 is in Install Program mode otherwise an internal tamper alarm will occur when leaving program mode B Access To Installation Program M ode from Operating Mode The Panel must be fully disarmed including monitor mode before you can access Program M ode You can access Installation Program Mode from normal Operating mode by pressing the following keypad sequence lt M aster Code gt Factory Default M aster Code is 123 The keypad will respond with 3 Beeps ddd all lights will go out and the Program light will come on steady You are now in CLIENT Program Mode To enter Installation program M ode from here press Note The Installer code is factory set at 000000 The keypad will respond with 3 Beeps ddd and the Program light will start flashing You are now in Installation Program M ode All program ming options can be programmed from this mode PROGRAMMING AAAA HOW TO PROGRAM Programming the NESS D 8 Control Panel is done via the remote keypad The PROGRAM or P button is used to begin any programming sequence As wewill call Program or P itin this manual The Numeric keys are used to enter a Programming Options b Programmed Values The ENTER or E button is us
14. 1 99 Zone is unsecured The displaying of the current value and setting of the NOTE The Entry Delay Time 2 is set in 10 second incre new value is done in the same way as Entry 1 Time ments instead of 1 second increments Eg Value set at 6 60 Seconds The factory pre set value 60 Seconds SUMMARY To VIEW the current Entry 2 Time ENTER Enter New Value if required to be changed and Press ENTER Current Value will b DE ae ds eu E 4 PROGRAMMING OPTION DESCRIPTIONS DnA P28 E SETTING EXIT TIME The Exit Delay Time is the time the control panel To view the current Exit Delay Time enter P 28E gives you to secure and depart the premises after the The value programmed will be displayed via the zone Panel is Armed 1 8 RADIO 9 and LINE 0 lights The Exit Delay Time can be set to a minimum of 1 To change the current value to say 30 seconds enter 30E second up to 99 seconds Zone 3 light will flash on for 1 second followed by the mains light 0 to indicate the new value The factory pre set value 60 Seconds SUMMARY To VIEW the current Exit Time ENTER Enter New Value and Press ENTER P a E Ju Score ddd eu E de PROGRAM MODES The Ness D 8 Control Panel has 3 modes 1 Installation Program M ode 2 Client Program M ode 3 Remote Programming via Remote Up and Down Loading or Direct Connect The Programming Options P 11E through to P 28E can be acces
15. E for 2 Seconds Only This Option selects which Outputs you wish to activate 2 SECOND MONITOR ALARM If P 64E 1E is Selected then the M onitor Zones as set up by programming Option P 51 E will turn on the outputs assigned by programming Option P 63 E for 2 Seconds lf P 64E 1E is not Selected then the M onitor Zones as set up by programming Option P 51 E will turn on the outputs to the Zones assigned by programming Option P 54 E to P 59 E for the Reset Siren Time The Factory Pre Set Off Zone 1 LED off PROGRAMMING OPTION DESCRIPTIONS P64E 2 E Day Zones as set up in Option P 53 E can activate outputs as set up in Options P 54E to P 59 E for the Siren Reset Time as set up in Option P 29 E or can activate outputs as set up in P 63 E for 2 Seconds Only This Option selects which Outputs you wish to activate If P 64E 2E is Selected then the Day Zones as set up by 2 SECOND DAY ALARM programming Option P 53 E will turn on the outputs assigned by programming Option P 63 E for 2 Seconds If P 64E 2E is not Selected then the Day Zones as set up by programming Option P 53 E will turn on the outputs to the Zones assigned by programming Option P 54E to P 59 E for the Reset Siren Time The Factory Pre Set On Zone 2 LED On P64E 3E If this programming Option P 64 E 3 E is selected then the Monitor Zones will all behave as Entry Exit Zones Therefore all zones will provide Exit Delay as set b
16. ENTER Zones set to activate the Sonalert BA CE ET old e E PROGRAMMING OPTION DESCRIPTIONS P 57 E SELECTING SIREN OUTPUT ZONES This option selects which Zones will activate the Zones set to activate the Siren Output will be lit Siren Output To De Select zones from activating the Siren Output enter To View what Zones are set to activate the Zone E To select it again enter the Zone then E again Siren Output enter P57E The Factory Pre Set ALL Zones set to Siren O P All Zone Lights On SUMMARY To VIEW the Zones that will activate the Siren output ENTER Enter Zone required to activate the Siren output then Press ENTER Z tto activate the Si E EE ser dus ee TE P 58 E SELECTING AUXILIARY OUTPUT ZONES This option selects which Zones will activate the Aux 1 Zones set to activate the Aux 1 Output will be on Output To De Select zones from activating the Aux 1 Output To view what zones are set to activate the Aux 1 Output enter Zone E To select it again enter the Zone then enter P 58E E again The Factory Pre Set No Zones set to Aux 1 0 P All Zone Lights Off SUMMARY To VIEW the Zones that will activate the AUX 1 ENTER Enter Zone required to activate the AUX 1 output then Press ENTER Ean CT E P59E SELECTING AUXILIARY 2 OUTPUT ZONES This option selects which Zones will activate the Aux 2 Zones set to activate the Aux 2 Output will be on Output To De Select zones from activating t
17. IO KEY three times For this code to operate option P 09E must be programmed with a 2 Access Code 2 set for Radio Key operation 2 To delete User 10 RADIO KEY P20E 0E NOTE If User code 10 needs to be a CODE the option P10E must have zone LED 2 Off Disabling code 10 from being a Radio Key PROGRAMMING OPTION DESCRIPTIONS e PROGRAMMING RADIO DEVICE CODES Program or Clear Zone Radio Device Code P01E P08E The D 8 can operate with Radio devices such as the Ness Radio PIR and both Radio Reed switch versions This makes the D 8 a very flexible system All radio devices are programmed with a Random code atthe fac tory it is possible though to program radio devices with the same 16 bit code except for the Mini Reed switch which random code cannot be changed The options POLE PO8E options are used to assign RADIO DEVICES to ZONE INPUTS The random code used by a Radio Device must be learnt by the panel to assigned it to a zone This is done by first selecting the zone using POLE for Zone 1 assignment to PO8E for Zone 8 assignment If a Radio device code is not programmed then the zone LED will be OFF If a Radio Device code already exists then that zone LED will be ON PREPARING DEVICES TO TRANSMIT When the Radio Device is ready to transmit Press 1E to start the code learning To program a Radio PIR to the D 8 connect the battery the PIR will transmit several messages when the code is accepted 3 beeps are given
18. M ode is the 15 User codes and Entry Exit Times NESS D 8 PROGRAMMING SUMMARY This summary is an outline of all options available in installation program mode The Enter key is required to display the values in each option eg P86E will display options 1 to 6 OPTION DESCRIPTION Tel No 0 Audible Radio Codes 1 8 Radio Key Enable Access Code 1 15 Entry 1 Time ntry 2 Time Exit Time Siren Time ormal Zone Sens Vib 1 8 Zone Sens ouble Trigger zones nstant Entry Zones Delay 1 Entry Zones andover Zones elay 2 Entry Zones Lockout Zones full Area 1 Zones Area 2 Zones Area 1 Access Codes Area 2 Access Codes Monitor Mode Zones 24hr Zones Day Zones Reset OP Zones Strobe Zones Sonalert Zones Siren Zones Aux 1 Zones Aux 2 Zones Entry Beeps K S Monitor K S Area 1 Tamper Lockout full Duress to Reset OP Auto Exclude Zones Keypad Display Off Delay Area 1 Area 2 OP Tamper to Reset OP Tamper to Strobe Op Tamper to Sonalert Tamper to Siren Keypad to Reset OP Keypad to Strobe Op Keypad to Sonalert Keypad to Siren D ni ni nil 6 6 5 1 nil EFAULT PIE 123 20 seconds seconds seconds minutes 08 OPTION DESCRIPTION View Memory Zone Exclude M onitor M ode Panic Area 1Arm Area 2Arm Auto Exclude 2s Warn Exit Time x 10 2 sec Reset OP Monitor M ode 2sec Strobe Monitor M ode 2sec Sonalert M onitor Mode 2sec
19. MANUFACTURED BY REA NESS SECURITY PRODUCTS PTY LTD A C N 069 984 732 Sydney Head Office Melbourne Ness Security Products Pty Ltd Ness Security Products Pty Ltd 4 167 Prospect Hwy 24 TerraCotta Drive Seven Hills NSW 2147 Phone 02 9624 3655 Fax 02 9674 2520 email ness ness com au Brisbane Ness Security Products Pty Ltd 36 Devlan Street Mansfield Qld 4122 Phone 07 3343 7744 Fax 07 3849 4883 email nessbris oznetcom com au Blackburn Vic 3130 Phone 03 9878 1022 Fax 03 9878 4257 email nessmelb ness com au Perth Ness Security Products Pty Ltd Unit 1 567 Newcastle Street Perth W A 6000 Phone 08 9328 2511 Fax 08 9227 7073 email nessper wcis netau Hong Kong Asia Unit B 5 f Comfort Building 88 Nathan Road Tsimshatsui Kowloon Hong Kong Phone 852 2721 8097 Fax 852 2721 7465 email pagen ness com hk Copyright by Ness Security Products Pty Ltd Release April 1998 To the best of our knowledge the information in this manual is correct at the time of going to print Ness Security Products reserve the right to make changes to the features and specifications at any time and without notice in the course of product development PART NO 890 137 D 8 CONTROL PANEL INSTALLATION MANUAL NESS SECURITY PRODUCTS A 15 00 12 D ou BR INTRODUCTION Features Package Contents Installation Procedures INSTALLATION Inputs Outputs Wiring Diagrams Sample
20. R All zone lights off SUMMARY To VIEW the Zones Set to Double Trigger Zones ENTER Enter Zone required to be set as a Double Trigger Zone and Press ENTER Zones Currently set as double P E Trigger Zones will be displayed ddd Value E ddd ZONE ASSIGNMENT The Ness D 8 can operate in 3 different modes Arm Mode 24 Hour Zones work independently of Arm Monitor when the Panel is Armed M onitor M ode or Disarm mode and Disarm Therefore a zone selected as 24 Hour will when the panel is Disarmed All zones can be pro be removed from Arm Monitor and Disarm Similarly grammed to operate in any combination of these 3 Panel selecting a zone as Arm Monitor or Disarm will remove M odes The Panel can also be broken into 2 Areas Area 1 it from 24 Hour 24 Hour Zones are always Instant and and Area 2 Zones can be programmed to be one of 4 turn on the same outputs regardless of the Panel types Instant Handover Entry Delay 1 and Entry Delay 2 Mode Armed Zone alarms can only be reset by a code or Radio Key assigned to the Area that the zone alarm occurred in ZONE TYPE DESCRIPTION P 40 E SETTING ZONES TO BE INSTANT An Instant Zone triggers an alarm the moment the zone is unsecured This can only occur when the panel is Armed and the Exit Time as set by P 28 E has expired Example To set say Zone 1 and Zone 2 to be Instant Enter P40E1E2E Factory Pre set Zones 3 to 8 Instant Zone lights 3 8 on SUMMARY To VIEW the Zo
21. Resistor D ALL Spare HI Zones rai i co 25 T Must be ht NS sealed with Tamper Alarm 12 0 QW Z4 Se ake Ohm N C N C Volts Volts 5 el Line resistor Ness Quantum Movement Detector EE z Dy O z2 P c 4 7 2K2 Ohm Resistor c N q alp D D Tamper Alarm 12 0 NIC NIC Volts Volts oV Ness Quantum Movement Detector 12V WIRING DIAGRAM Sample Wiring of Reed Detectors Sample Wiring of Reed Switch and Nessensor Wiring to Ness Control Panel Zg er Note Other Two Wires are Looped and are for NC Tamper BS l Must bi za Ph sueled with rl 3 e Ness Vibration Nessensor oO a P Lies resistor i EO L Ramstor c hom E 0 L Resistor i z Oo 2 l ee C2 MAGNET un N E O L resistor S S a wip MAGNET MAGNET N D INSTALLATION WIRING DIAGRAM Sample Wiring of Warning Detectors Sample Wiring of Warning Devices to Ness Control Panel EO L Resistor fens Ness Control Panel WIRING DIAGRAM Wiring of D 8 Keypads Sample Wiring of Ness D 8 Keypad to Ness D 8 Control Panel
22. Siren Monitor M ode 2sec Reset OP Day Mode 2sec Strobe Day Mode 2sec Sonalert Day Mode 2sec Siren Day Mode 2sec Monitor Mode 2sec Day Mode Monitor Zones delayed K S Chirp amp Flash 50 60Hz M ains Frequency Double Key Panic S cut Fire Key 3 S cut Medical Key 2 el No 1 primary el No 2 secondary AccountNo 1 Account No 2 eport Zones iscellaneous Alarms eport Zone Restores Miscellaneous Alarms Restore Multi Zone Report Account 2 Zones Tel No 3 for test calls Tel No 4 for Up Download Zone Restore immed Zone Restore after siren Zone Restore on Disarm amp Seal Zone Restore always on Disarm Test Call Interva Test Call Start Delay Dial tone detect Always Decadic Always DTMF DEFAULT OPTION DESCRIPTION Disable Dialler Contact ID format Audible DTM F Format Audible Pulse Format Contact ID Audible DTM F format Contact ID Audible Pulse format Alternate Pri Sec Tel No Dial tone detection required 4 10 dial attempts Area 1 Open close reports Area 2 Open close reports Double Siren chirp on closing 2 sec Strobe on closing orced opening report on alarm Enable Test Calls ains Report Delay Swinger shutdown ine Fault Monitor nable Up Download Enable Up Download direct Enable Remote Arming nable Remote Disarming Enable Remote Aux 1 nable Remote Status reporti Enable Remote Event Report emote rings Clear Event Memory
23. able these outputs to activate only after Exit time enter P 60 E 8 E AREA 1 amp AREA 2 OUTPUT ON AFTER EXIT TIME The Zone 8 LED will indicate if this option is selected With Zone 8 LED On The Area 1 Output will active at the end of Exit time when the Area is Armed and with the Zone 8 LED Off the Output will activate immedi ately the Area is Armed NOTE This option also controls the output for area 2 Factory Pre Set Outputs Activate Immediately Area is Armed ie Zone 8 LED Off PROGRAMMING OPT ION DESCRIPTIONS P61E 1E 4E SELECTING TAMP This option selects which Outputs will be activated if a Tamper Alarm occurs Options P 61E 1E to P 61 E 4E selects outputs to activate as follows P 61E 1E Selects the Reset Output P 61E 2E Selects the Strobe Output P61E3E Selects the Keypad Sonalert Output P 61E 4E Selects the Siren Output To View what Outputs will activate on a Tamper Alarm P61E ER ALARMS TO ACTIVATE OUTPUTS The Zone 1 4 LED s will light to indicate which of the 4 options are set to activate on a Tamper Alarm To De Select Outputs from activating on a Tamper Alarm enter the option ie 1 to 4 then ENTER To select it again enter the option then ENTER again The Factory Pre Set ALL Outputs to Activate on Tamper Alarm Zone Lights 1 to 4 On SUMMARY To VIEW what outputs will activate on a Tamper Alarm enter Pl a E Tamper Alarm Condition 1 Reset O P 2 Strobe
24. am M ode as well as operating the panel Factory Default M aster Code 123 Options P 12 E P 25 E User codes 2 15 can only operate the panel Note 1 Codes can be 3 to 6 digits in length 2 User codes cannot start with 0 3 All codes must be unique to each other 4 When entering codes you must enter it twice for verification To clear an existing code you must re program that code with a number that starts with 0 USER CODES ACCESS CODES Example To program a M aster Code Press P 1 E JJJ code E J code E JJ Example To program a Master Code to be 2468 Press P u EJI 2468 E J 2468 E JJ Example To program Code 2 to be 6789 Press P 2 E JJJ smo E J er E Ju Example To Delete CODE 2 create a code and startit with a 0 P 2 ElI 06518 E al 06518 Br To Delete ALL CODES Including the M aster Code and Installation Code Press Ple E JJJ PROGRAMMING OPTION DESCRIPTIONS PROGRAMMING RADIO KEY CODES Programming a Radio Key to Codes 2 15 To Assign Access Code 2 8 to a Radio Key PO9E To Assign Access Code 9 15 to a Radio Key P10E Radio Key codes must be assigned to Access codes the same as Access codes being assigned to Areas The following options describe how to assign radio keys to access codes NOTE By selecting a radio key to an access or user code will disable the use of a code that may be programmed into a user code address User Access Codes 2 to 15
25. an Area 2 Zone use the same method above to switch the Zone light off ie P 46 E 1 E Selects Zone 1 1 E again de selects the Zone Example To set say Zone 1 5 7 and 8 to Area 2 enter P46E1E5E7E8 Factory Pre set No Zones are set to be Area 2 All Zone lights off SUMMARY To VIEW the Zones Set as Area 2 Zones ENTER Enter Zone required to be set as Area 2 Zones then Press ENTER eG Re u A 8 4 P47E P48E ASSIGN USER CODES TO AREA 1 The Ness D 8 has 15 User codes which can be selected to operate either or both of the 2 Areas Option P 47 E Selects which of the User codes 1 to 8 can Arm and Disarm Area 1 Option P 48 E Selects which of the User codes 9 to 15 can Arm and Disarm Area 1 Example To set say Users 1 2 6 9 11 and 15 to operate Area 1 enter P47E1E2E6E P48E1E3E7E The 8 Zone lights will display what Users have been selected for Area 1 Factory Pre set All Users are set to be Area 1 All Zone lights on SUMMARY To VIEW the User codes 1 8 Set as Area 1 Codes ENTER Enter Code required as Area 1 Codes then Press ENTER 20 0 PS E 4 To VIEW the User codes 9 15 Set as Area 1 Codes ENTER Enter Code required as Area 1 Codes then Press ENTER 28 FE 4 Note Zone 1 will display User Code 9 Zone 7 will display User code 15 PROGRAMMING OPTION DESCRIPTIONS P 49 E P 50 E ASSIGN USER CODES TO AREA 2 The Ness D 8 has 15 User codes of which any can be can Arm and Disarm Ar
26. are assigned to Radio Keys with these options Entering POSE displays User Codes 2 to 8 that are to be Radio Key or code operated Zone LED s that are on rep resent access codes that are set for radio keys Entering P10E displays User Codes 9 to 15 that are to be Radio Key or code operated with code 9 status dis played on zone 1 LED etc Now enter the User Code number to either select or delete Radio key operation For PO9E use the keys 2 8 to select users 2 8 For P10E use the keys 1 8 to select users 9 15 Factory Pre set 0 User codes assigned to KEYPAD RADIO KEY ACCESS CODE programming 1 First select the code numbers to have RADIO KEY ACCESS with Assign Access Code programming options P 09 E P 10 E 2 Code Lis barred from RADIO KEY ACCESS 3 To learn a RADIO KEY i Select the User Access Code P12 E to P25 E The response is 3 beeps if it has been assigned RADIO KEY ACCESS ii Select 1E to start the panel RADIO KEY learning iii Press the OFF button three times on the radio key to be learned A code already in use is rejected by giving one long beep If the response is 3 beeps the code has been accepted 4 To clear a RADIO KEY i Select the User Access Code P12 E to P25 E The response is 3 beeps if it has been assigned RADIO KEY ACCESS ii Select OE to clear the code The response is 3 beeps Examples 1 To program User 2 to learn a new RADIO KEY P12E 1E then press the OFF button on the RAD
27. as XYZ Alarm type the message format is fixed which saves time when GG Group or Area designation programming CCCC Alarm number Suffix Event Checksum Simply programming both telephone numbers and the client account number will enable the dialler to operate Some other programming may be required to setup the dialler to suit your customers requirements REPORT NAME Account Number rm rm rm rm a es OE al Mains Fail PROGRAMMING OPTION DESCRIPTIONS REPORT NAME Zone 1M Zone 2M Zone 3M Zone 4M Zone 5M Zone 6M Zon Zone 1 Auto Exc Zone 2 Auto Exc Zone 3 Auto Exc Zone 4 Auto Exc Zone 5 Auto Exc Zone 6 Auto Exc Zone 7 Auto Exc Zone 8 Auto Exclude DIALLER OPTIONS All Dialler options are programmable in Installation Program Mode The Follow Me Telephone Number Option PO0E can also be programmed in Client Program mode Telephone No 1 and No 2 P70E P71E The D8 can dial up to 2 phone numbers when an Event message is to be transmitted to a remote location This may be a Central Station or a private telephone for audible format The Telephone Numbers may be up to 15 digits long Telephone No Lis the Primary phone number and is pro grammed using Option P70E This is the M ain telephone umber for the central monitoring station Telephone No 2 is the Secondary phone number and is programmed using Option P71E Pauses star or hash V F digits can be included in the dia
28. ble Zone inputs Q 1 x 24 hour Tamper input Each input must be terminated with a 2K2 2 200 ohm end of line resistor as supplied These inputs must be sealed with this EOL resistor regardless if they are being used as detection inputs or not The inputs are protected against transient spikes through modern circuit board design If there are two detection loops being used for any single zone input then cable security may be provided on both loops as shown in the series Zone diagram below Note Each pair of zones share a common terminal Ordinary Zone Connection R zone D com Q R 2K2 Series Zone Connection R zone D E com R i R 1K or 1K2 The Tamper input is wired in an identical manner to the Zones It MUST be fitted with a 2K2 end of line resistor If you have 2 external siren covers each cover can be individually monitored by wiring as described in the series zone diagram The Tamper common does not have a dedicated terminal The Tamper common can be the 0 Volt terminal next to the Tamper terminal or any of the other zone input common terminals For wiring details of Keypads Keyswitches Panic Buttons and Warning devices see the wiring diagrams in the wiring section of this manual AC Input Terminals These terminals are for the connection of the Ness plug pack The Ness D 8 requires an AC transformer rating of 1 4 Amps 17 Vac minimum Ness Part No Pow 215 Battery These plug in terminals are
29. cate various warnings such as 10 beeps for loss of Mains Power or Low Battery Installation of Keypad e Unclip the top half of the housing by pushing the top clips down with a small screwdriver and pulling the housing forward Screw the base of the keypad hous ing to the wall using the 4 mounting holes provided Bring the 4 connecting wires to the terminal block on the PCB that is mounted on the lid of the Keypad housing Connect the wires to the screw terminals as per the wiring diagram shown in this manual Clip the top half onto the base by first engaging the bottom clips and swinging the top closed Push hard to ensure the clips engage Attach the Zone list label on the inside of the hinged lid Keypad Wiring The D 8 Keypad connects to the D 8 Control Panel via a 4 wire connection A Maximum of 3 keypads can be con nected each wired in parallel The maximum cable run is 100M using 14 0 20mm cable If the cable is shared then divide 100m by the number of keypads to be connected eg 2 keypads on the cable reduces the maximum run to 50M Dialler Telephone Line Wiring The D 8 dialler connects to a telephone line via a Mode 3 or 5 socket A Mode 3 or 5 connection allows the dialler to cut off any existing devices eg phones faxes etc and seize the telephone line so it can dial out This method gives priority to the D 8 dialler If a Mode 3 or 5 is not available on site then a Mo
30. d triggers unwanted alarms of it s own accord The maxium number of alarm messages any zone can send with this option on is 3 Factory Pre set On Limit the number of alarm messages sent P89E 5E ENABLE LINE FAULT MONITOR This option seclects if the Line fault monitoring is operational If selected ON the keypad sonalert will beep and the line LED will flash if the line voltage drops below 2 volts Factory Pre set On Enable Line Fault M onitor ENABLE REMOTE PROGRAM UP DOWNLOAD P90 E1E ENABLE REMOTE PROGRAM DIRECT CONNECT P90E2E ENABLE REMOTE ARMING P9O0OE3E ENABLE REMOTE DISARMING P90E4E ENABLE REMOTE AUXILIARY OUTPUT CONTROL P90 E5E ENABLE REMOTE STATUS REPORTING P90E6E ENABLE REMOTE EVENT REPORTING P90E7E PROGRAMMING OPTION DESCRIPTIONS P96E This Option will clear all events from memory CLEARING ALARM MEMORY To clear the event memory simply Press P fs JE dd P97E This Option when entered returns ALL programming options back to factory Default settings DEFAULT PANEL The Factory Pre Set Refer the Summary Page for a Summary of all factory Default Values P98E This Option when entered deletes the 15 user codes CLEAR ACCESS CODES 1 15 The Factory Pre Set No Codes P99E The Installation access code is the code required to access Installation Program M ode from Client Program M ode This option allows you to set your own access code The following rules apply to setti
31. de 3 double adaptor can be used This allows for a dialler and phone to be connected at the same socket These double adaptor plugs are available from retail outlets The dialler must always be connected directly to the incoming phone line Connecting to a PABX line may lessen your security and or increase the problems you may encounter On some PABX systems the dialler may not work at all eg Do not connect to an extension line of a Telstra Commander system EARTH TERMINAL For increased protection of the system electronics against lightning strikes connect a good Earth to the Earth Terminal on the D 8 INSTALLATION a VISUAL INDICATIONS Zones l 2 3 4 5 6 7 8 kady 68866 EG e Armed Am2 Memory Radio Mans Exclude line battery Tamper Program LIGHT OFF ON w FLASH Zone Unsealed s Zone Alarm Panel is Armed w M onitor M ode Panel is Armed Normal w M ains Fail Normal w Battery Low Memory M ode Selected w Alarm in Memory Panic Alarmhas been activated Only displayed in M emory w Zones Excluded Exclude M ode Selecte orma w Tamper Alarm Install Program ZONEs 1 8 Zone Sealed ARMED Day Disarm ARM 2 Day Disarm MAINS BATTERY MEMORY orma EXCLUDE orma TAMPER O O O PROGRAM O Norma O O O ClientM ode Selected M ode selected When dialler failed When dialler message is w to c
32. e 84 x 2 168 hours 7 days PROGRAMMING OPTION DESCRIPTIONS oo U Uee P 384E This option determines the time in hours before the next test call message is sent to the central station M ost central stations prefer that test calls be sent when the central station traffic is low between midnight and 4AM If you wish to check the test call message program this option to 0 zero and then reprogram for the correct time after testing The Time Before Next Test Call is programmable from 2 to 198 Hours as per the Time Between Test Calls option above The Test Call Time is derived form the AC Mains signal to give thie most accurate timing Ensure P64E 5E 50 60 Hz M ains is correctly set otherwise the times will be incorrect TIME BEFORE NEXT TEST CALL The time before test call interval can be between 2 hours and 198 hours in 2 hour increments Note that the value program range is from 1 to 99 and is multiplied by 2 to give the actual time eg If you are leaving program mode to start the time before test timer at approx 3PM and you require the test call at approx 1AM the next morning then press P 84E5E for 10 hours before the first test call The Time Before Next Test Call is constantly updated eg When viewing this option the time displayed is the actual time before the next test call is due not what was originally programmed in Factory Pre set 0 Instant test call AAAA P85E DIALLING METHOD This opti
33. e Reset Output enter Zone E To select it again enter the Zone then enter P54E E again The Factory Pre Set ALL Zones set to Reset 0 P All Zone Lights On SUMMARY To VIEW the Zones that will activate the reset output ENTER Enter Zone required to activate the reset output then Press ENTER FEU E a P55E SELECTING STROBE OUTPUT ZONES This option selects which Zones will activate the Strobe Zones set to activate the Strobe Output will be lit Output To De Select zones from activating the Strobe Output To View what Zones are set to activate the Strobe Output enter Zone E to select it again enter the Zone E again Enter P55E The Factory Pre Set ALL Zones set to Strobe O P All Zone Lights On SUMMARY To VIEW the Zones that will activate the Strobe output ENTER Enter Zone required to activate the Strobe output then Press ENTER Pan 4 P 56 E SELECTING KEYPAD SONALERT OUTPUT ZONES This option selects which Zones will activate the Zones setto activate the Sonalert Output will be lit Keypad Sonalert Output To De Select zones from activating the Sonalert Output To View what Zones are set to activate the Sonalert enter Zone E To select it again Enter the Zone then E again Output Enter P 56 E Factory Pre Set ALL Zones setto Sonalert O P All Zone Lights On SUMMARY To VIEW the Zones that will activate the Sonalert output ENTER Enter Zone required to activate the Sonalert output then Press
34. e central station Different central sta tions request that Alarm restore reports be sent at varying times This options caters for the central station require ments Note Only 1 of the following options may be selected ZONE RESTORE REPORTING Send Restore Immediately the input reseals 2 Send Restore after the siren time and the zone has resealed 3 Send Restore after Opening report and the zone has resealed 4 Send Restore after Opening report irrespective of the Zone input state The type selected will be displayed by the Zone LED s Factory Pre set 4 After an opening regardless of the input state Zone 4 light on DN e P83E Test calls from the D 8 are an important way in which the central station can determine if the dialler is operating This becomes even more important if Open and Close reports are not sent This option determines the time period between the Test calls The Test call interval can be between 2 hours and 198 hours in 2 hour increments Note that the value program range is from 1 to 99 and is multiplied by 2 TIME BETWEEN TEST CALLS eg If you required the D 8 to send a test call every 24 hours press the following sequence P83E 12 E By pro gramming as shown the D 8 would send the test calls every 24 hours The programmed value is multiplied by 2 by the D8 to derive the Test Call time oOo These Auto Test calls are then Enabled or Disabled by Option P86E Factory Pre set 84 i
35. ea 2 selected to operate either of the 2 Areas or both if Example To set say Users 1 3 10 12 to operate Area required 2 enter Option P 49 E Selects which of the User codes 1 to 8 can P47E1E3E Arm and Disarm Area 2 P48E2E4E Option P 50E Selects which ofthe User codes 9 to 15 The 8 Zone lights will display what Users have been selected for the Area 2 Factory Pre set Users Code 1 Only set to be an Area 2 code Zone 1 lights on SUMMARY To VIEW the User codes 1 8 Set as Area 2 Codes ENTER Enter Code required as Area 2 Codes then Press ENTER 100 ME sou To VIEW the User codes 9 15 Set as Area 2 Codes ENTER Enter Code required as Area 2 Codes then Press ENTER 16 FES E wu Note Zone 1 will display User Code 9 Zone 7 will display User code 15 PROGRAMMING OPTION DESCRIPTIONS P 51E Monitor Zones allow you to ARM selected zones while oth ers are ignored Typically Perimeter zones doors and win dows can be Monitored while you are at home The Zones selected to be Monitor Zones will be Armed when the panel is putinto M onitor Mode as wellas when the panel is fully Armed Monitor Mode allows a User to Arm those zones with a simple Keypad operation Monitor Zones will operate when the Panel is in Monitor M ode ie Armed indicator on the keypad flashes There are 2 different ways to use Monitor Mode 1 If Programming option P64E 1 E refer below is selected Monitor Zones will turn on the out
36. ects which Outputs will be activated when the Panel is in Day Mode ie Disarmed and an Alarm occurs These outputs will activate for 2 Seconds if set with Option P 64 1 E On Options P 63 E 5 E to P 63 E 8 E selects outputs to activate when a Day Zone Alarm occurs are as follows P 63E 5E Selects the Reset Output P 63E 6E Selects the Strobe Output P 63E 7E Selects the Keypad Sonalert Output P 63E 8E Selects the Siren Output DAY MODE OUTPUTS To View what Outputs will activate when in M onitor M ode enter P 63E The Zone 5 8 LED s will light to indicate which of the 4 options are set to activate in Day M ode The Factory Pre Set Reset amp Strobe Outputs to Activate only by Day Zone Zone Lights 5 amp 6 Only On Note Refer option P 64E for more information about acti vating these outputs SUMMARY To VIEW what outputs will activate when a Day Zone Alarms ENTER P E Day Alarm Activates 5 Reset O P 6 Strobe O P 7 Sonalert O P 8 Siren O P Zone Lights 5 8 will indicate what outputs are to be activated when a Enter Output required to activate when a Day Zone Alarms then Press ENTER JJJ E JJ 5 Reset O P 6 Strobe O P 7 Sonalert O P 8 Siren O P P64E 1 E Monitor Zones as set up in programming Option P 51 E can activate outputs as set up in Options P 54 E to P 59 E for the Siren Reset Time as set up in programming Option P 29 E or can activate outputs as set up in P 63
37. ed to signal the end of the button sequence just entered or As we will call itin this manual The programmed value is displayed by illuminating the Zone 1 8 Line 0 and Radio 9 lights The particular type of indications are described for each option in the following pages Installation Programming Options can be carried out in any sequence The program sequence always follow s the pattern shown below Select your option and view the current Value P 2 Digit Option E EXAMPLE Enter new value s w Le E Eg To change the Entry Time which is programmed by programming option 26 from the factory default setting of 20 seconds to 15 seconds press the following keypad sequence P E E eee 1E TE 1 Note Every time you press ENTER the keypad will beep in acknow ledgment Three quick beeps JJJ will acknowledge all is OK and accepted and one long beep 4 J indicates an invalid entry PROGRAMMING OPTION DESCRIPTIONS PILE P25E A user code is a code the client uses to operate the panel The Ness D 8 has a total of 15 user access codes plus one code which is the Installer access code as set by Option P 99 E and is used only for access to Installer Program Mode The remaining 14 codes are used for arming disarming etc These codes are assigned user numbers 1 to 15 Options P 11E P 25 E Option P 11 E User code Lis the master code The mas ter code is the only code which can access Client Progr
38. er dialler operations The Factory Pre Set On 50Hz operation P64E 6 E This option if set On gives Double Key Panic A Panic alarm is activated by pressing both Panic keys together Selecting both this option and P62E 4E allows Panic to be used both ways DOUBLE KEY PANIC ALARM The Factory Pre Set Off No keypad panic alarm if both Panic keys pressed P64E 7E FIRE ALARM This option if set On gives a Fire Alarm A Fire alarm is acti vated by pressing Key 3 and then enter If Fire alarm is selected all outputs will trigger Entering a valid code will reset the alarm and send a restore report if selected The Factory Pre Set Off No keypad fire alarm operation P64E 8 E MEDICAL ALARM This option if set On gives a medical Alarm A Medical alarm is activated by pressing key 2 and then Enter If Medical alarm is selected NO outputs trigger Entering a valid code will send a restore report if selected The Factory Pre Set Off No keypad Medical alarm Operation PROGRAMMING OPTION DESCRIPTIONS DIALLER OPTIONS The Ness D 8 has an onboard dialler which reports to the The D 8 dialler uses standard Contact ID format and a central station using Ademco Contact ID format and is also detailed breakup of these reports are listed below capable of Audible format to allow the dialler to call a private telephone number AAAA Client Account Number Q Event Qualifier The D 8 dialler is very easy to program and setup
39. ets as used with answering machines 4 If the dialler does not receive the kiss off tone it will re dial and repeat the sequence This will continue for up to 9 dial out attempts 5 If the phone is answered prior to the 5 second wait time as described in 2 above there will be silence until the time has elapsed The message from the dialler may be manu ally started by pressing any one of the buttons as described in 2 and 4 above the tone generated by the phone acts as an acknowledge tone NOTE In some cases where a Telecom 200 series phone is used and tone dialling is not available at the telephone exchange by pressing the MODE button will allow tones to be generated If Audible Dial Formatis selected the D 8 will not send 1 Auto Exclude Reports 2 Manual Excludes Reports 3 Mains Fail Report 4 Low Battery Report Note DO NOT select Restoral reports when Audible format is used P76E P77E All LED s Off Refer to POOE which programs Phone Number 4 and is used for the follow me Telephone number for Audible Format Factory Pre set Option 2 On CONTACT ID PROGRAMMING OPTION DESCRIPTIONS P87E MISCELLANEOUS DIAL OPTIONS VE P87 1E This option changes the order in which TEL No 1 amp 2 are dialled Alternate dial Zone LED 1 ON Dial Telephone No 1 on the first attempt If no responce dial Telephone No 2 If no responce dial Telephone number 1 etc etc Continue alternating between telepho
40. he Aux 2 Output To view what zones are set to activate the Aux 2 Output enter Zone E To select it again enter the Zone then enter P59E E again The Factory Pre Set No Zones set to Aux 2 0 P All Zone Lights Off SUMMARY To VIEW the Zones that will activate the AUX 2 ENTER Enter Zone required to activate the AUX 2 output then Press ENTER Aa E Ce E PROGRAMMING OPTION DESCRIPTIONS MISCELLANEOUS OPTIONS P 60 E LE Whenever a Delay Zone is unsecured when the panel is Armed and Entry Time begins the Keypad Sonalert begins to Beep To Disable Entry Warning Beeps Enter P 60E 1E ENTRY WARNING BEEPS With Zone 1 LED On Entry Warning Beeps will be Enabled and with Zone 1 LED Off the Entry Warning Beeps are Disabled Factory Pre Set Entry Beeps Enabled ie Zone LED 1 On P60E2E3E normally open momentary Keyswitch can be used to Arm Disarm or put the panel to Monitor Mode If a Keyswitch is required itis wired to Zone 8 A short on the Zone input will operate the panel as a Keyswitch activation An Open Circuit will generate a 24 Hour Keyswitch Panic alarm Zone 8 2K2 i 7 Momentary Keyswitch Be KEYSWITCH OPERATION When P 60E 2E is selected the Panel will change to Monitor or Disarming only on each momentary Keyswitch shorting of the Zone 8 input When P 60E 3E is selected the Panel will change from Arming and Disarming only on each shorting of the Zone 8
41. hen Area lis on Area 2 Arming This output is an open collector switch negative which can supply 100mA This output is turned on when Area 2 is Armed Aux 1 This output is an open collector switch negative which can supply 100mA Zone alarms may be selected to trig ger this output by option P58E Aux 2 This output is an open collector switch negative which can supply 100mA Zone alarms may be selected to trig ger this output by option P58E INSTALLATION WIRING DIAGRAM M ain Control Panel r Dialler lead for consection to telephone network NC Ext Tamper DIALLER SOCKET e MO nc RECEIVER EEE L262 a a gt AUX Le AUX 2 4 7 e ARM 1 OPEN COLLECTOR ARM 2 OUTPUTS Fe 12v gt ov Power for Detectors Etc DAT boos 21446708 sin sessmese Ama COM Am tomy aco ely Mons cuo im Keypad atoy bmo rogom ser Piezo Siren PEER i MICROPROCESSER PS to a Speaker luc 240 V Plug Pack Earth DEPPEPEPEE A E ot load 12 Ack O Battery INSTALLATION WIRING DIAGRAM Sample Wiring of Movement Detectors Sample Wiring of Ness Movement Detector to Ness Control Panels ze Oe eee ox Note aan 2K2 Ohm
42. high x 85 deep 5 kg inc battery Input 240 Vac 50Hz Output 17Vac 1 4A 13 8Vdc 850mA current limited 100mA with Keypad 20mA per additional keypad 11 5V 14V DC 12V 3 2 to 6 5AH Lead Acid 13 4 13 8V float 350mA max current limited Every hour and when the panel is armed and disarmed 10 75V with 5A load 2A resettable 500mA resettable 200mA resettable 300mA 12V End of Line Resistor 2 200 ohm 1 200 900 ohm End of Line Resistor 2 200 ohm 1 200 900 ohm Proprietary 3 Open Collector 500Hz 2700Hz 3X 8ohm Open Collector Fused 200mA 12v Open Collector Fused 1A Open Collector 100 mA IMPORTANT TEST POINTS AND VOLTAGES 12 V Output Terminals Battery Terminals Zone amp Tamper Inputs Siren Reset Strobe A C Terminals 13 2 13 8V DC load connected with a charged battery 13 4 13 8V DC no battery connected 6 8V 0 32V DC 13 2 V 13 8V DC via fuse F1 13 2 V 13 8V DC via fuse F1 17 21 VAC GETTING STARTED WITH A BASIC PROGRAM Factory Pre Set Value Zone 1 Zone 2 Zones 3 8 Exit Delay Entry Delay 1 Siren Time Entry Warning Alarm Outputs Shortcuts Delayed Handover Instant 60 Seconds 20 Seconds 5 Minutes Beeps Enabled 1 Upon completing the installation of the Panel take link off the PROGRAM TAM PER pins and power up the with M ains Power 2 The Program light will start to flash indicating the Panelis in Installer Program Mode 3 Program in
43. igh Sensitivity Example To set say zone 5 to be used with a Nessensor through to Vibration Sensor and set to a Medium sensitivity enter P 38 E Low Sensitivity P34E5E The factory Pre set value No Zone set Vibration ie all zones set to normal P 30 E all zone lights On SUMMARY To VIEW the current Vibration Setting ENTER Enter Zone if required to be changed and Press ENTER 30 Current Zone will be NOTE Nessensors are very sensitive to high frequencies and insensitive to low frequencies Therefore it is not necessary to apply much force to the protected structure rather a very rapid succession of blows instead The sensitivity has been correctly adjusted when a single blow applied with a soft object eg by hand does not cause an alarm whereas a rapid series of blows preferably with a hard object such as a screw driver handle will cause an alarm PROGRAMMING OPTION DESCRIPTIONS P 39 E DOUBLE TRIGGER ZONES Zones selected as Double Trigger Zones will be Example To set say zone 3 and zone 6 to be double triggered as an alarm only if trigger zones enter P39E3E6E 1 The zone has triggered twice in a 4 minute period 2 Any 2 zones both programmed to be double trigger When you select this option the zone lights will indicate each alarm once in a 4 minute period what zones are set to double trigger 3 The zone is left unsealed for longer than 15 Seconds Factory Pre set ALL ZONES SET TO SINGLE TRIGGE
44. ing P74E will display the zones set to send alarm messages to the central station Zone alarm messages may be selected to report on Client Account 2 by using option P79E This option might be used if the system is split into two areas Factory Pre set All Zones set to report alarm messages All zone lights on el P75E MISCELLANEOUS ALARMS This option selects which Miscellaneous Alarms are sent to the central station See table above for miscellaneous alarm selection All miscellaneous events eg Tampers Panics Mains Fails will report on Client Account No 1 Factory Pre set All Miscellaneous Alarms set to report All zone lights on PROGRAMMING OPTION DESCRIPTIONS p P76E ZONE ALARM RESTORED This option selects which zones will report zone restorals to the central station Option P82E determines when the restoral message is sent Factory Pre set All Zones set to report All zone lights on P77E MISC ALARMS RESTORED This option selects which Miscellaneous Alarms will send a restoral report to the central station Miscellaneous Alarms which have been selected to send a Restore report P77E will always send the Restore report when a valid code is entered to reset an alarm or at Opening Factory Pre set All Alarms set to report All zone lights on IN P78E MULTIPLE ZONE ALARMS This option selects
45. ll Areas Cannot Access installation program M ode Installation Code entered in run mode Enter client program mode first using the instead of client program mode Master code then enter the install code Installation Code lost Power down the system fully then power up in Program Mode Control Panel not starting up when Excess load connected to the Power Check for short circuits and excessive load AC Power is applied Supply Current limit protection operating on the power supply outputs The Heat Sink is warm to touch Normal Operation This is normal operation Sirens Strobes or Detectors not working Resettable Fuse tripped Check for short circuits on the outputs The Internal and External sirens sound The Panel has been Armed with a zone Disarm the Panel secure the unsecured for 2 seconds at the end of siren time unsecured zone and then Re Arm MECHANICAL Construction Dimensions Weight POWER Plugpack Power Supply Quiescent Current Operating Voltage Rechargeable Battery Batt Charge Voltage Batt Charge Current Dynamic Battery Test Dynamic Battery Test Fuses 1 Power outputs 2 Aux 12v Power 3 Strobe Power Output for Optional Equipment INPUTS Zone Input Tamper Input Remote Keypad Input Maximum Keypads OUTPUTS Siren Outputs Maximum Sirens Strobe Output Reset Output Area Signal Output SPECIFICATIONS 3 mm Polycarbonate equivalent to 1 2 mm mild steel 233 wide x 300
46. lling sequence by using the keys in the table below The star or hash may be required for some PABX systems or when using Telstra s Easy Dial system Both and are used in speed dialling a service which may be offered by the telephone network provider 5 CE CO E CE CE EE ans fo fn foo fom fr _ aus fe fn fe fm GG Displayed on Pause 1 6 sec Armed Light Arm 2 Light Hash Exclude Key To view the current Phone numbers enter P 70 E for Primary Number or P 71 E for Secondary Number The value programmed will be displayed via the zone LED s 1 8 Radio LED 9 Line LED 0 pause Arm Arm 1 LED and M ains LED To change the current Phone number simply enter the new number followed by ENTER The new phone number will then be displayed TIP To quickly clear a telephone number Press the Memory Key after the option Eg To clear telephone number 2 Press P71E Memory key E NOTE If telephone No 1 is cleared then all dialler report ing is disabled If telephone number 2is disabled all calls are made on telephone number 1 and the setting of P87E 1E has no effect Factory Pre set Tel No cleared PROGRAMMING OPTION DESCRIPTIONS P72E P73E Client Account Numbers are used by the Central Station to identify the location of the alarm premises The client account numbers are generally given to the installation company by the central station Having two alarm systems with
47. mary Sheet Dialler Telephone Lead Circuit Board Standoff INSTALLATION PROCEDURES For ease of installation it is recommended that the following procedure be follow ed Nr re The location of the main panel housing should be in an area that is within the protected area of the premises A linen closet or cupboard are good examples as these generally located in the centre of the Premises Positioning of the movement detectors should be considered as the incorrect position may cause unwanted alarms 2 H g Standoffs t e to plugin i as shown 0 d r 1 4 p ex A bt 5 MINNA NANANNNNNNNNNNNNNNNNNT 1 Unclip the lid by pushing in the directions ofthe arrows 1 and 2 as shown below wiring instructions shown in this installation manual 2 Remove the Battery from the base 6 Replace the Battery 3 Mount the rear panel housing to a secure location 7 Insert the panel tamper bracket as shown below 4 Insert the PCB stand offs in the Panel and then plug 8 Program Installation options refer pages 16 36 the circuit board onto the stand offs HU bial 9 Perform the power up check and carry out test 5 Wire to the circuit board terminal blocks as per the procedures refer Page 47 48 INSTALLATION R INPUTS Monitored Zones The Ness D 8 has 9 separate monitored inputs 8 x Fully programma
48. n Alarm from the System until it is sealed again or until the panel is disarmed The 2 second Siren Burst can be disabled when Auto excluding by Selecting P 62 E 7 E This option will Disable the Auto Exclude function When disabled a Zone unsealed at the end of exit time will cause the panel to go into Alarm and not automatically Exclude the Zone AUTO EXCLUDING OF ZONES To Disable this Auto Exclude function enter P 60 E 6 E The Zone 6 LED will indicate if the option is selected With Zone 6 LED On the Auto Exclude function is Enabled and with the Zone 6 LED Off the Auto Exclude function is disabled Factory Pre Set Auto Exclude Enabled ie Zone 6 LED On P 60 E 7E This option when selected will turn off all LED indicators on the Keypad if no keypresses have occurred within 4 minutes useful to stop annoying lights in a bedroom Any activation of the keypad via Beeps or pressing of any key will restore the LED s DISABLE THE DISPLAY To Enable this Display Disable function enter P 60 E 7 E The Zone 7 LED will indicate if the option is selected With Zone 7 LED On The Display Disable function is Enabled and with the Zone 7 LED Off the Display Disable is disabled Factory Pre Set No Disabling of LED s ie Zone 7 LED Off P 60 E 8E The outputs marked Area 1 turns on immediately Area 1 is Armed This programming option when selected will turn Area 1 output on only after exit time has expired To En
49. ne numbers until successful or when the maximum number of attempts is reached SPLIT DIAL OR ALTERNATE Splitdial Zone LED 1 OFF Dial Telephone No 1 for half the number of the call attempts If unsuccessful dial Telephone No 2 for the last half of the call attempts The D 8 will also call telephone No 2if Telephone No 1was succcessful NOTE This option is ignored if Telephone No 2 has not been programmed Factory Pre set On Alternate between telephone No 1 and No2 ro P87 2E This option selects Dial without dial tone The dialler will attempt to dial regardless of a dial tone being heard or not This option may have to be used on some PABX systems or if the dial tone is weak The Dialler will always try and obtain a valid dial tone first DIAL WITHOUT DIAL TONE Zone LED 2 On Only dial telephone number with a valid dial tone Zone LED 2 Off Dial immediately without a dial tone Used for PABXs with non standard dial tones etc The D8 will dial Decadic first and then V F DTM F Factory Pre set On Dial with dialtone lt P87 4E 4 OR 10 DIAL ATTEMPTS Zone LED 40n allows a maximum 4 dial out attempts before a 5 minute sleep time and 4 more retries if unsuccessful Zone LED 4 Off sets a maximum 10 dial out attempts before a 5 minute sleep time and 10 more re tries if unsuccessful If all attempts fail the dialler waits for the next dialler acti vation event The previously unsuccessful re
50. nes Set as Instant Zones ENTER Enter Zone required to be set as an Instant Zone and Press ENTER Zones Currentl 106 CE ow 6 PROGRAMMING OPTION DESCRIPTIONS P 41E ENTRY DELAY 1 ZONES After expiry of the Exit Time as set by P 28 E a Delay 1 Example To set say Zone 4 and Zone 7 to be Delay Zone becoming unsecured will cause an alarm at the Enter P4lE4E7E end of the Entry 1 Time as set by P 26 E if the Panel Factory Pre set Zone 1 set to Delay 1 timer has not been Disarmed Zone light 1 on SUMMARY To VIEW the Zones Set as Entry 1 Zones ENTER Enter Zone required to be set as an Entry 1 Zone and Press ENTER Zones Currently Set as Entry 1 PF QE l E ue Be E 4 P 42 E HANDOVER ZONES A Handover Zone is a combination of a Delay zone and Handover should not be selected for the actual point of an Instant Zone After Arming the Handover Zone is entry zones eg front door Deer next Bel ae aS Aray PRE Example To set say zone 4 and zone 5 to be Handover It then automatically reverts to an Instant Zone to provide greater security for detectors on the delay path ZONE SENSE RARESESE If a normal entry is made through a delay zone then Factory Pre set Zone 2 set to Handover Zone 2 light on Handover zones change to delayed operation again to enable time to enter and Disarm the Panel without triggering an alarm SUMMARY To VIEW the Zones Set as Handover Zones ENTER Enter Zone required to be
51. ng the Installation Code Example To program an Installation Code to be 9876 Press Ae Ew Cm INSTALLATION ACCESS CODE 1 The Installer Codes can be 3 to 6 digits in length 2 The Code cannot start with 0 except if you are returning it to factory default which is 000000 3 The Installation Code cannot be the same as a User code as set by P11E P25 E 4 When entering codes you must enter it twice for verification fe 4 H u CHECKS BEFORE EXITING PROGRAM MODE All 24 Hr inputs are active immediately you exit Program M ode Therefore after installation programming has been completed there are some basic checks that should be performed in order to save frustration and possible embarrassment 1 Check that the External Tamper is properly terminated with a 2K2 resistor 2 If you have enabled Zone 8 as a Keyswitch Panic input make sure it is also terminated with a 2K2 resistor 3 Ensure rear Panel Tamper is secured 4 Ensure any zones set as a 24 Hour Zone are sealed with a 2K2 resistor 5 Make sure the Program Link is connected FAILURE TO COMPLETE THESE TASKS WILL RESULT IN THE CONTROL PANEL GOING INTO ALARM AS SOON AS INSTALLATION PROGRAM MODE IS EXITED You are now ready to exit Program Mode This is done by entering P E PE EXITING PROGRAM MODE To exit program mode you must enter PROGRAM followed by ENTER P E TESTING AND TROUBLESHOOTING TESTING To ensure reliable operation of an
52. ny existing code The response is 3 beeps Examples 1 Zone 4to learn a new RADIO DEVICE P 04E 1E then TRIGGER the RADIO DEVICE 2 To clear Zone 5 RADIO DEVICE POSE 0E Factory Pre set All device codes are cleared PROGRAMMING OPTION DESCRIPTIONS ooo P26E SETTING ENTRY TIME 1 The Entry Delay Time 1 is the time the Control Panel To view the current Entry Time lenter P 26 E gives you to disarm the Panel after an Entry 1 Delay The value programmed will be displayed via the zone Zone is unsecured 1 8 RADIO 9 and LINE 0 lights The Entry Delay Time 1 can be set to a minimum of 1 To change the current value to say 10 seconds enter 10E second up to a maximum of 99 seconds Zone 1 light will flash on for 1 second followed by the mains light 0 to indicate the new value The factory pre set value 20 Seconds SUMMARY To VIEW the current Entry 1 Time ENTER Enter New Value if required and Press ENTER P 2 E Ju ut Jus eu E 44 Note Every time you press ENTER the keypad will beep in acknowledgment Three quick beeps d will acknowledge all is OK and accepted and one long beep d d indicates an invalid entry P27 E SETTING ENTRY TIME 2 The Entry Delay Time 2 is the time the control Panel The Entry Delay Time 2 can be set to a minimum of 10 gives you to disarm the Panel after an Entry 2 Delay seconds up to a maximum of 990 seconds
53. ommunicate or LINE orma being transmitted a line fault exsists Zone unsealed READY Scie Ready To Arm The System Line Fau Radio Key or Device Low Radio Key or RADIO Norma Battery when displayed in memory Be NOTE Radio 9 and Line 0 are used in program mode to flash out values PROGRAMMING ACCESS TO THE INSTALLATION PROGRAM MODE There are two programming modes within the Ness D 8 Control Panel 1 Installation Program Mode gt Program Light Flashes In Installation Program Mode all programming options can be changed This mode is used by the installer to set up the entire system The Program light on the Systems Keypad flashes while in Installation Program mode 2 Client Program Mode r Program Light On steady In Client Program M ode only the 15 User Codes and Entry Exit Time and Follow me phone number can be changed The Program light on the Systems Keypad is on Steady while in Client Program mode NOTE If no keypad but tons are pressed for 4 minutes the panel will leave Client Program M ode The Installer Program Mode is entered whenever pro gramming options are changed by the installer It can be accessed in two ways A Access To Installation Program M ode from Initial Power Up Whenever Mains or Battery Power is applied for the first time and the PROGRAM Pins are opened ie by removing the Link across them the panel will enter Installation Program M ode The keypad
54. on is selected then the Exit Time will now be the time in P 28 E 220 seconds 22 x 10 220 Factory Pre Set No Increased ie Zone 8 LED Off P63E 1 4E MONITOR MODE OUTPUTS This option selects which Outputs will be activated when To View what Outputs will activate when in Monitor the Panel is in Monitor Mode and an Alarm occurs These Mode enter P 63E outputs will activate for 2 Seconds if set with program ming Option P 641E is seton The Zone 1 4 LED s will light to indicate which of the 4 options are set to activate in Monitor Mode Options P 63 E 1 E to P 63 E 4E selects outputs to activate when a Monitor Zone Alarm occurs are as follows The Factory Pre Set No Outputs to Activate by Monitor Zone Zone Lights 1 to 4 Off P 63E 1E Selects the Reset Output Note refer programming option P 64 E for more P 63E 2E Selects the Strobe Output information about activating these Outputs P 63E 3E Selects the Keypad Sonalert Output P 63E 4E Selects the Siren Output To VIEW what outputs will activate when a M onitor Zone Enter Output required to activate when a goes into Alarms ENTER Monitor Zone Alarms then Press ENTER Zone Lights 1 4 will indicate what outputs are to be activated whena P E Monitor Zone Alarms in Monitor J J J J dd Mode 1 Reset O P 1FReSEEOIP 2 Strobe O P 2 Strobe O P 3 Sonalert O P 3 Sonalert O P 4 Siren O P Fairen Orr PROGRAMMING OPTION DESCRIPTIONS P63E 5 8 E This option sel
55. on sets the method used to dial out There are three choices and the following dialling methods can be selected 1 Automatic The dial format is determined by the detected Dial Tone 2 Decadic Pulse Dial only 3 V F DTM F Dial only The dialling method selected should be set to suit the phone line Note If no tone is detected after looping the line then the dialler will attempt to dial regardless using Decadic first and then V F dialling in an alternate method In the majori ty of cases there will be no need to change this option To view the current method of dialling Press P 85 E zone LED s 1 to 3 will come on to show the selected method Factory Pre set 1 Automatic PROGRAMMING OPTION DESCRIPTIONS P86E P86E 1E DISABLE DIALLER P86E 2E CONTACT ID FORMAT P86E 3E AUDIBLE DTMF FORMAT P86E 4E AUDIBLE PULSE FORMAT P86E 5E CONTACT ID AUDIBLE DTMF FORMAT P86E6E CONTACT ID AUDIBLE PULSE FORMAT Explanation of P86E options 3 to 6 Option 3 Audible DTM F The last digit of the client account number is sent in DTMF format followed by the Alarm num ber in DTMF format eg client code 1234 with alarm zone 7 System will send a DTMF 4 then a DTMF 7 Option 4 Audible pulse The last digit of the client account number is pulsed in Pulse format followed by the Alarm number in Pulse format eg client code 1234 with alarm zone 7 System will send 4 beeps pause then send 7 beeps to indicate zone 7 alarm Op
56. port will be included in the new message The Line LED will flash to indicate the message has not been successful Factory Pre set Off 10 dial attempts PROGRAMMING OPTION DESCRIPTIONS P88E 1E Zone LED 1 ON allows Area 1 Open Close reports Zone LED 1 OFF disables Area 1 Open Close reports SEND AREA 1 OPEN CLOSE REPORTS Factory Pre set Off No Area 1 open close Note If split area operation is not used default all zones to area then this option must be selected for open clse reports to be sent P88E 2E Zone LED 2 ON allows Area 2 Open Close reports Zone LED 2 OFF disables Area 2 Open Close reports SEND AREA 2 OPEN CLOSE REPORTS Factory Pre set Off No Area 2 open close P88E 3E 2 SEC SIREN ON KISS OFF On selects a 2 Second Siren burst on a successful Closing report Zone LED 3 ON selects a 2 Second Siren Burst on a successful Closing report Zone LED 3 OFF disables 2 Second Siren Burst on a successful Closing report Factory Pre set Off No kissoff siren P88E 4E Zone LED 4 ON selects a 2 Second Strobe Burst on a successful Closing report Zone LED 4 OFF disables 2 Second Strobe Burst on a successful Closing report 2 SEC STROBE ON KISSOFF Options 3 and 4 are used to give the User an indication that the Dialler has successfully sent the ARMING report and the dialler is working correctly when they Arm their system and leave the premises Factory Pre set Off No kissoff strobe P88E 5E
57. puts assigned by Programming option P63E refer below for 2 Seconds 2 If Programming option P64E 1 E is not selected M onitor The factory Pre Set Monitor Zones No Zones SELECTING MONITOR ZONES Zones will turn on the outputs assigned to the zones as set by Programming option P54E P59 E refer below and the outputs will behave as normal Note in this case P64E 3E must not be selected Refer below To also have pre alarm warning in M onitor even on Instant Zones If Programming option P64E 3 E is selected Monitor Zones will all behave as Entry Exit zones This allows the user to have a Sonalert pre warning of a monitor alarm If Programming option P64 E 3 E is not selected Monitor Zones will behave as programmed for the zone types as per P40E P43E Example To set say Zones 1 3 and 7 to be Monitor Mode Zones Enter P51E1E3E7E All Zone Lights off SUMMARY To VIEW the Zones Set to activate in Monitor Mode ENTER Pl E Enter Zone required as Monitor Zone then Press ENTER be active during M oni we Bw P 52E 24 Hour Zones are Armed at all times regardless of the mode of the panel operation ie Armed Disarmed or Monitor When alarmed these zones will activate assigned outputs immediately Example To set zone 6 to be a 24 Hour zone Enter P52E6E SELECTING 24 HOUR ZONES Factory Pre Set 24 Hour Zones No Zones No Zone Lights On 24 Hour Zones work independently of A
58. rmed Monitor and Disarmed Therefore a zone selected as 24 Hour will be removed from Night M onitor and Day Similarly selecting a zone as Night Monitor or Day will remove it from 24 Hour 24 Hour Zones are always Instant and turn on the same outputs regardless of the Panel Mode SUMMARY To VIEW the Zones Set as 24 Hour Zones enter Enter Zone required as a 24 Hour Zone then Press ENTER Ao ee ow ee 4 PROGRAMMING OPTION DESCRIPTIONS P 53E SELECTING DAY ZONES Day Zones operate when the panel is in a totally disarmed 2 If Programming option P64E 2 E is not selected Day state ie When Area 1 Area 2 and Monitor M ode are all off Zones will turn on the outputs assigned to the zones as set by Programming option P54E P59 E refer below and When alarmed these Zones will activate the assigned the outputs will behave as normal outputs instantly There are 2 different ways to use Day Zones Example To set zone 5 to be a Day Zone enter P53E5E 1 If Programming option P64E 2 E refer below is select ed Day Zones will turn on the outputs assigned by Factory Pre Set Day Zones NO Zones Programming option P63E refer below for 2 Seconds No Zone Lights On This is useful for daytime doorway monitoring SUMMARY To VIEW the Zones Set as Day Zones ENTER Enter Zone required as a Day Zone then Press ENTER 100 4s oo When a zone alarms it can turn on any or all of the fol M onitor and Day Zone
59. s can be assigned to switch these lowing 4 outputs Reset Strobe Keypad Sonalert and Siren Outputs as well using Option P 63 E Note these are only active when programmed with Programming option P64 E The NESS D 8 allows for each zone input to be selected as refer below to what outputs they will activate Tamper and Monitor outputs are displayed on Zones 1 4 while Panic and Day outputs are displayed on Zone LEDs Programming options P 54 E P 59 E select which Zones 5 8 The following table shows a summary of these pro will activate these outputs The Tamper input and Keypad gramming options and how the panel is programmed as Panic can be programmed to select which of the above 4 default from the factory outputs will turn on when they are activated This is achieved by programming option P 61E OPTION P 61 E OPTION P 63 E Option Tamper Monitor Reset 1x 1x Strobe 2x 2x Son irt 3x 3x Siren 4x 4x x Factory Pre set Note The Reset Siren output will turn on for the duration of the alarm timer P 29 E or until it is reset via a valid code The Strobe outputs latches until reset by a valid code PROGRAMMING OPTION DESCRIPTIONS P 54E SELECTING RESET OUTPUT ZONES This option selects which Zones will activate the Reset Zones set to activate the Reset Output will be lit Output To De Select zones from activating the Reset Output To view what zones are set to activate th
60. sed in ALL modes of programming Excluding P 98 E and P 99E The following programming Options can only be accessed in Installation Program Mode ALL Program options are programmable using the Windows Based Up Down Load Software mm P29E SETTING RESET TIME The siren reset time sets the Audible Alarm s operating To view the current Siren Reset Time enter P29E time This is fixed for both the siren output and the The value programmed will be displayed via the zone resetting output 1 8 Radio 9 and Line 0 lights The siren reset time can be set to a minimum of 1 minute To change the current value to say 10 minutes Enter 10 E up to 99 minutes Zone 5 light will flash on for 1 second to indicate the new value The factory pre set value 5 Minutes Note Check the Local Gov t By Laws before increasing this value SUMMARY To VIEW the current Siren Reset Time ENTER Enter New Value if required to be changed and Press ENTER P s E du eur Ju eu E Ju PROGRAMMING OPTION DESCRIPTIONS P30E P38E VIBRATION SENSITIVITY ZONES When using vibration sensors such as the Nessensor P 30E is for normal zones that do not use vibration sensors VIB 100 any of the 8 zones can be programmed with Sensitivity 1 and 8 ie Programming address P31E and P38E individual sensitivities should not normally be used they are provided as a guide to the upper and lower limits only There are 8 sensitivities P 31 E H
61. settable fuse A maximum load of 500mA may be connected to these terminals Siren The Ness D 8 has an on board siren driver therefore only horn speakers should to be connected to this out put A maximum of 3 x 8 Ohm horn speakers Ness Part No NOI 110 or 100 171 Internal Siren can be connected to this output This output will reset at the end of siren time or whenever the panel is reset whichever comes first This output has an internal Resettable fuse Strobe A latched 12V DC voltage output for connecting strobes This output will latch on in the event of an alarm and stay on until the panel is reset A maximum of 2 x 1 Watt Strobes Ness Part No NOI 300 can be connected to this Output This output has a Resettable fuse Reset A non latched 12V DC voltage output controlled by the Siren Timer P29E for connecting NESS SIRENS piezo sirens or relays etc A maximum of 3 x 12 Volt Piezo Sirens Ness PartNo NOI 240 NOI 230 or 2 X Ness Piezo Sirens Part No 100 172 can be connected to this output Note A maximum output of 2 0A continuous is available in total from the Reset and Siren Outputs ie a Total of 4 siren devices being a combination of 12 Volt Piezo Sirens connected to the Reset Output AND 8 Ohm Horn Speakers connected to the Siren Output can be con nected in total to the System Area 1 Arming This output is an open collector switch negative which can supply a maximum 100mA It switches negative w
62. the Master Code by Entering P 11E Code E Code E Factory Default master Code is 123 4 The System is Factory Pre Set as follows Any program option can be changed easily following the instructions as described in this manual 5 Replace the Link onto the PROGRAM TAM PER Pins and make sure the Panel Lid is now on sealing up the Panel Tamper switch 6 Press the P then the E keys 7 The system now operates using the basic program All Outputs active on an Alarm Condition Arm Shortcut enabled ie ARM ENTER to Arm the Panel Access To Program Mode from Operating Mode to make any program Changes The Panel must be fully disarmed including monitor mode before you can access Program Mode You can access installation program mode from normal operating mode by pressing the following keypad sequence P lt M aster Code gt E The keypad will respond with 3 Beeps ddd all lights will go out and the Program light will come on steady You are now in CLIENT Program Mode The only programming options that can be accessed from this M ode are the 15 User codes and Entry Exit Times To enter Installer Program Mode from here press P lt Installer Code gt E Note The installer code is factory set at 000000 The keypad will respond with 3 Beeps ddd all lights will go out and the Program light will flash You are now in Installer Program Mode The only programming options that can be done from this
63. the same client account number can make life very confusing at the central station Care must be taken to ensure this does not happen Area 1 Open Close reports will report on Client Account 1 and Area 2 Open Close reports will report on Client Account 2 Zone Alarms can be assigned to report on either Client Account Numbers as set by Option P79E This may be required if the system is split into two areas All miscellaneous events eg Tampers Mains Fail will reporton Account No 1 CLIENT ACCOUNT NUMBERS To program Client Account Number 1 Press P72E client account number E To program Client Account Number 2 Press P73E client account number E To view the current Client Account Numbers enter P72E for Account No 1 or P 3E for Account No 2 The value programmed will be displayed via the zone 1 8 battery 9 and mains 0 lights To change the current Account number simply enter the new number followed by ENTER The new account num ber will then be displayed In Audible format the last digit of the client code is used Factory Pre set 0000 for both P74E P79E ALARM REPORTING TABLE Displayed on LEDs 1 8 P74E Report Alarms Default P76E Report Restores P78E Report Multiple P75E Report Alarms P77E report Restores Install Prog P74E ZONE ALARMS This option selects which zones will send an alarm 130 message to the central station using client account number 1 Press
64. tion 5 Contact ID DTMF Audible This option will send a Contact ID message to the central station then send the DTMF Audible format to the Follow Me number Option 6 Contact ID Pulse Audible This option will send a Contact ID message to the central station then send the Pulse Audible format to the Follow Me number Audible format works in the following manner 1 When an alarm triggers the D8 it will dial the pro grammed telephone number 1 as normal 2 At the end of the dialling sequence when the dialler dials it s last digit the D8 will wait for five 5 seconds then com mence the audible message The audible message will continue to be repeated for a full 45 seconds or until it is kissed off by a DTMF tone whichever comes first 3 The dialler needs to be kissed off shut down by press ing any of the following buttons 2 3 5 6 8 9 0 or on a phone capable of outputting tones The button should be pressed at the end of the series of fast beeps The tones from the dialler will stop If by pressing the buttons once on the telephone does not stop the dialler it maybe worth while pressing the button twice quickly to stop the dialler beeping and turn the dialler off AUDIBLE DIAL FORMAT OPTION NOTE Some Telephones do not generate long enough tones for the Dialler to recognise In these cases a hand held tone generator can be used These are available from Dick Smith Tandy and similar electronic retail outl
65. to P 62E 6 E selects how you wish cer tain functions within the system to operate Keypad operations can be programmed to operate with or without a User Code If you Select the operation to oper ate without a user code this is known as Shortcut The operations available for use as shortcuts are as follows P 62E 1E Memory Display Shortcut P62E2E Zone Exclude Shortcut P 62E 3E Monitor Mode Shortcut P 62E 4E Enable Medical amp Fire Alarms P 62E5E Area 1 Arming Shortcut P 62E6E Area 2 Arming Shortcut Note Allocate an access code to Area 2 refer P 49 E before programming both Area 1 amp Area 2 shortcut arming 5 E and 6 E above If Area 2 is shortcut armed then it will always remain armed This will bar entry into program mode until Area 2 is Disarmed SYSTEM OPERATING SHORTCUTS With the option selected ie Zone LED s 1 to 6 On to show Options 1 6 Selected or not When shortcut operation is selected a User Code is not required to access that function Example With P 62 E 2 E Exclude Shortcut selected to access exclude mode you only need press the EXCLUDE key followed by ENTER key If shortcut is not selected then to access Exclude Mode you would need to press EXCLUDE then an authorised USER CODE followed by ENTER If User I D reporting is required back at the control room then the client must Arm the System using a Code Therefore Arming Shortcut must be disabled
66. tput P60E 5E Auto Excluding of Zones P60E 6E Disable the Display P60E 7E Area 1 Output on after Exit P60E 8E Tamper Alarms to Activate selected Outputs P61E 1E 4E Panic Alarms to Activate selected Outputs P61E 5E 8E System Operating Shortcuts P62E1E 6E Auto Exclude W arning P62E 7E Exit Time x 10 P62E8E M onitor M ode Alarm to Selected Outputs P63E 1E 4E Day Mode Alarms to Selected Outputs P63E 5E 8E 2 Second Monitor Alarm P64E1E 2 Second Day Alarm P 64E2E Pre Alarm Monitor Warning P64E3E Chirp Outputs on Keyswitch Control P64E4E Dialler Options Telephone Number 1 and 2 P70E P71E Client Account numbers P72E P773E Alarm Reporting and Restorals P74E P79E Telephone Number 3 Test Call Number P80E Telephone Number 4 VP Download Number P81E Zone Restore Reporting P82E Test Call Options P83E P84E Dialling M ethod P85E Miscellaneous Reporting Options P86E P87E Open and Close Options P88E Miscellaneous Dialler Options P89E Up Down Load amp Remote Control Options P90E Default Panel Program P97E Delete Access Codes P98E nstallation Access Code P99E Exit Programming PE Testing and Troubleshooting Voltages SPECIFICATIONS GETTING STARTED WITH A BASIC PROGRAM PROGRAMMING SUMMARY NOTES INTRODUCTION The NESS D 8 is Australian Designed and Manufactured product by Ness Security Products Pty Ltd Australia s largest manufacturer
67. which zone sends an alarm report each time the zone alarms Zones notselected report only once until reset by an opening or a valid code The number of alarms sent for each multiple zone alarm can be limited by using the swinger shutdown option P89E 4E Factory Pre set All Zones set to report All zone lights on n a rarer rrr P79E CLIENT CODE 2 ZONES This option selects which zone alarms and zone exclude messages will be reported on Client Account number 2 This function may be necessary if two premises are shar ing a common D 8 system eg Two shops which are side by side are sharing the D 8 system then this option allows each shop to have separate client account numbers for alarm reporting Factory Pre set No Zones set to report All zone lights off s P80E TELEPHONE NO 3 Phone Number 3 is used to enable and send Test Calls If this option is not programmed then TEL No 1 amp TEL No 2 are used Factory Pre set No Phone Number PROGRAMMING OPTION DESCRIPTIONS J eae P81E TELEPHONE NO 4 This option is used to program the remote site Up Down Load Phone Number When using the Call Back operation when Up Down Loading telephone number 4 is the number the panel will dial to connect to the Up Down modem Factory Pre set No phone number fT I UUU P82E All Zone Alarms may be selected to Report Alarm Restores This option selects when the Restore message will be sent by the Dialler to th
68. wo end of line Q Fully programmable via the systems Keypad resistors so that two detection devices Eliminates the need for expensive ie reed switches can both be monitored programmers or Proms to provide maximum security Inbuilt Vibration Sensor Analyser Q 20 Event Memory Q All programming data is permanently stored in a Q Radio Compatible with up to 8 Detection Devices non volatile EEprom more secure than and 14 User Remote Controls battery backed up memory Q All inputs and Outputs are heavily protected Windows based Up Dow n load Software allows against lightning and high voltage supply remote programming and event status transients An earth terminal is provided for Q True Dynamic Battery Test every time the extra protection Panel is armed disarmed and every hour Q 15 User Codes Area Partitionable 2 Areas Any Zone can be Q Automatic Resettable Fuses programmed to any area as well as common areas Q Programmable Inputs to activate selectable Outputs Q Designed utilising the latest SM D Technology Q Forced Arming Feature Q Simple to Program and Use Australian Designed and M anufactured INSTALLATION D UNPACKING The D 8 package contains the following Contents Quantity D 8 Control Panel 1 D 8 Backlit LED Keypad 1 D 8 Zone List 1 17 Volt A C Plugpack 1 12 Volt 7 A H Back Up battery 1 Optional 2K2 End of Line Resistors 10 Housing cover screws 2 D 8 Users M anual Programming Sum
69. y pro gramming Option P 28 E and all will provide Entry Delay as set by programming Option P 26 E with entry Warning Beeps even if the Zone is normally an Instant Zone Note Entry beeps will only occur if P60E1E is ON PRE ALARM MONITOR WARNING If Option P 64 E 3 E is Not Selected then the M onitor Zones as set by programming Option P 51 E will behave as pro grammed for the Zone types as set in programming Options P 40 E to P 43 E ie Instant Entry Delay or Handover The Factory Pre Set On Zone 3 LED On P64E 4E If Zone 8 is programmed as a Keyswitch Input as pro grammed by option P 60 E 3 E itis possible to provide an Audible warning to the client via the Siren output This is very useful when using Radio Keys to remote Arm and Disarm the Ness D 8 panel If this option is selected the Siren Output will Chirp when KEYSWITCH ARM DISARM CHIRPS the panel is Armed Disarmed with this Keyswitch input Note these Chirps will only occur when the Keyswitch Input is used to Arm and Disarm and not when the Keypad is used The Panel will provide 1 Chirp for Arming and 3 Chirps on Disarming The Factory Pre Set Off Zone 4 LED Off P64E5E This option is used to select either 50Hz or 60Hz mains power frequency operation Australia and NZ operate at 50 Hertz M ains Frequency 50Hz 60Hz MAINS FREQUENCY It is only active when periodic dialler test reports are required It has no effect on local or oth
70. y system correct testing procedures should be carried out prior to handing the completed installation over to the customer Using a digital multimeter the following procedures are recommended for testing a Ness L 8 control system VOLTAGES All zone inputs and the tamper input should be terminated with a 2K2 ohm end of line resistor supplied with the Panel When correctly secured the voltage reading across each zone input should be 6 8V or 0 32V DC If the voltage reading is above or below this reading check your detector wiring and cabling Check that the DC output to the detectors is 13 4 to 13 8 Volts DC When checking any input for the above voltages ensure that the zone is sealed and secure TROUBLESHOOTING Keypad not working correctly Keypad wired incorrectly or excessive Check keypad wiring for polarity cable resistance and resistance User code not being accepted Code already programmed for another user Select another user code Note the restrictions or code forms a subset of another code of code sub sets in the user manual User code is programmed successfully Code programmed may begin with a 0 Reprogram the code User codes beginning but not accepted in normal mode with 0 are used to clear codes Cannot Access Client Program M ode Code being used to Access Client Program Use the Master Code as programmed under Mode is not the M aster Code Option P 11E as set by P 11E Area 1 or Area 2 is armed Disarm a