        RF Touch - MATTIOLI engineering
         Contents
1.                                                            26  Appendix A   ENVIRONMENTAL CONSIDERATIONS                   26  BODY AREA                              14 Appendix B                                 27  TREATMENTS tee twit bk      UU UU T 15                              OF BIPOLAR PROTO OD               mi  MOD za A A A A A A AAA 15 Appendix D     LIST OF UNIPOLAR PROTOCOLS    30  START e Appendix E   DECLARATION OF RESPONSIBILITY                      33                                                        TECHNICAL a EORNM PRSE 10 01            Ref  5801 2220 RF TOUCH    INFORMATION ON THIS MANUAL    This manual is addressed to      user of the machine      owner      responsible      people in charge of moving      installers      Users      people in charge of maintenance     This document provides valuable information regarding the installation  set up and  use of RF TOUCH aesthetic equipment for radiofrequency mono and bipolar  treatments     It is a useful and essential reference guide for the user  read the contents of the  manual carefully before installing the equipment and keep it on hand at all times for  future reference     It is of vital importance that you strictly adhere to the recommendations contained  within the manual in order to avoid malfunction  which may cause damage to the  equipment and consequent annulment of the validity of the warranty     Furthermore  in order to obtain the highly efficient technical service available from  the man
2.     Ordinary maintenance should be performed on the device prior to each use in order  to verify the integrity and security     In particular  before each use  you must     L  check that the power supply cable is intact and connected to the electric  network     L  examine to view the entire equipment for any damage     LI check that there are not traces of humidity in the vicinity of the device  especially  on the connectors     L  After treatment  turn off the unit and remove the power suplly cable from the  electric network if not should be used immediately     Whenever there are any signs of damage to the cable  replace it before putting the  device into work with the equal supplied at the beginning        The RF TOUCH properly installed  in good repair and used according to the rules  is  not considered hazardous for the operator or for the customer during its use     L  Before using this system  check that the voltage is 230 V  50 Hz   Do not place objects on the equipment     Do not install or store the unit near heat sources  or exposed to rain or moisture       DL    If any should fall into or there was accidentally spilled  immediately disconnect  the equipment from the network and have it checked by qualified personnel  before operating it again     L  Clean the cabinet with a soft cloth lightly dampened  not dripping  with water  and mild detergent or alcohol or furniture  do not use abrasives or solvents     LI Do not open or disassemble the equipment for any rea
3.     RF Touch         USER MANUAL    Ref  5801 2220 RF TOUCH    INDEX         t  t ret ese ca vic A          16  INFORMATION ON THIS MANUAL        ccccccccccccccccecccceccceccccecccccceccceccccececcccccececccccces 2 CLIENT CARD                         16  WRITING CONVENTIONS        2 EREATE GAN                      tes ake ia                     16  OPEN                                            16  WARRANTY roeoeoeooooooooooooooooooooesososooososososososososesesesesesonosonenonononononononononononononoosososnen 3 MODIFY a CARD     ed 17  NOTES    000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 3 PROCEDURES                                                      17  CAUTIONS                         3 T A i7  I       WARNING     esee enne tenete nnne tenete tenente nnne tenete tenenti 4        17  INTRODUCTION OF THE TECNOLOGY                     6           ee a          18  TREATMENT PROCEDURE       02aeeeeeeeeouoooooeeeoosooeeeeeaaoooooseseaaosooeeeesaoosooeeeesaaoaoeeeeeoaanooe 7 Wb     18  51 10  LO  010  KA A A A AN 18         3           AN ERR 8  BAK                                18   INTENDED RU SRM 8  Tope  e              8                                                18                                                                                                                                      9 ami        18  PRELIMINARY NOTES     c ccccccccccsccssscssccsccsscsssccsccceccssccsccssccssccsccsse
4.     Stylus pen touch screen display  Bottle of conductive cream 1000ml     Inserts electrodes diameters 30mm J            Inserts electrodesdiameters 40mm J        Inserts electrodes diameters 50mm J            Inserts electrodesdiameters 60mm              Inserts electrodesdiameters 70mm     J        Inserts electrodes diameters 80cm           The connection of the applicator is simple  you need to connect the end plug of the  cable to the connector on the back of generator  making sure that the connector pins  are inserted correctly  then screw the ferrule to block the connector        Contact authorised dealears MATTIOLI ENGINEERING S P A  for problems or difficulty  installation     CONNECTIONS    The power entry module can be found on the back of power supply and consists of a  three pole socket for the cable set  an extractible fuse box with two fuses  see  technical specifications  and the main switch ON   OFF of power supply     Plug the power supply cable three pin plug into the integrated board and ensure that  it is correctly plugged into the connector     When using an extension lead  make sure that it has been earthed     Failure to comply with the above instructions may lead to dangerous electrical  discharge causing machine damage and harm to persons     The general switch ON OFF of generator can be found on the rear panel of generator     Once you have checked that installation and assembly have been carried out  switch  on the general switch ON   OFF of power
5.     WRITING CONVENTIONS    Certain sections of the manual have been underlined in order to highlight their  importance     NOTE    These contain important information and useful tips for operating the equipment     CAUTIONS    The CAUTION message appears before operations  which  if not correctly performed   may cause damage to the machine and or its accessories     This signals operations or situations  which  if unknown to the operator  or incorrectly  carried out  may harm the operator        Ref  5801 2220 RF TOUCH    1  unplug the machine and any connections  devices  applicators etc      WARRANTY 2  carefully clean and disinfect all parts of the machine and accessories which have  been in contact with clients     MATTIOLI ENGINEERING S P A  guarantees the quality of its products for a period of Any equipment which the technical department does not consider hygienic  Italian  24 months from the date of purchase  when information contained in this manual law T U S  81 2008 on safety in the workplace  will not be accepted     regarding installation  use and maintenance is strictly adhered to and the warranty    coupon is returned within 15 days of purchase  3  disassemble accessories and any mechanical supports     The guarantee covers the replacement of faulty parts  4  use original box and packing materials     5  enclose detailed information regarding the nature of the problem in order to  facilitate the technical department s intervention and save time on repair     NO
6.     treatment  Output cables worn and or with   5875 of wear on head and  power supply    faulty contacts  cable   Mains cable worn or blocked  Replace mains cable  LUIS  Failure in electronic current         ENGINEERING S P A  service  Plug in properly the connection generator circuit   roperly connected to the AN DO lal ee e    m  i      connector on      back of     Non si accende il    generator  Carry out prescribed   display LED sul maintenance  Install and  vansellodrontates    Connecuonmultipelancable warn Contact an MATTIOLI Non perfectly efficient connection position unit as described   l apparecchio Man   r blocked ENGINEERING S P A  service on handle applicator output circuit  Make sure applicator cable and                              connector        in good    Mains cable not properly connected  to the connector of power supply    Connection multipolar cable not    conditions   General switch ON   OFF of Power   Turn general switch on the The device works  Supply off  back of Power Supply on  properly  but a fall  in treatment  effectiveness is  observed     Mechanical damage  following a fall  or violent impact  of the probe   applicator  especially on the  radiating head     Ensure that the radiating head  adheres perfectly to the  treatment surface     General switch ON   OFF of Turn general switch on the  generartor off  back of Generator on     Replace missing  faulty or  blown fuse s   Electronic circuit of generator not  perfectly calibrated  Contact an 
7.    6  at the end of the countdown an information window will appear  THERAPY  ENDED     7  press OK to confirm and close the window    The count and the issue will continue until   e       timer expires  in which case the system will emit a long beep warning      you click the button PAUSE which pauses the treatment      you click the button STOP that ends the treatment     Check that the electrode inserted corresponds to the selected display     IMPORTANT  if necessary  replace the electrode only when the device is in PAUSE or  STOP phase     NOTE  to replace the electrode during treatment is absolutely necessary to put the    PAUSE device or stop the treatment before  otherwise you may encounter  malfunctions        15    Ref  5801 2220 RF TOUCH    SAVE    ANAMNESIS    5  Acton its commands to insert the data   To save the treatment protocol     th b   o to the fields from time to time you will see a virtual alphanumeric  i NO        DUELON  keyboard  finished click ENTER to confirm  2  inthe window that appears  select the type of memory where you want to save         inthe event of changes to PROTOCOL  will appear on the full list and the  the personalized program     scroll bar  click on the item to select it or the data  3  touch the frame for inserting data and write the name of the file using the virtual    o if you change any other field  use the virtual alphanumeric headboard to  keyboard     enter new data  finished click ENTER to confirm  4  to click on ENTER to c
8.    By pressing the LANGUAGE icon it is possible to select the language settings of the  equipment     Once you have selected the desired language by pressing the corresponding line on  the list box  press the virtual button OK to enable the loading of the selected  language     All messages and controls of the equipment will be shown in the selected language   DISPLAY  By pressing the DISPLAY button it is possible to select the display settings      CALIBRATION       SCREEN SAVER    To calibrate the equipment display   1  press the SCREEN CALIBRATION virtual button     2  follow the instruction shown a screen     Once the calibration process is complete  an updating screen is displayed  then  returns to the previous screen     To enable a SCREEN SAVER    1  press the SCREEN SAVER virtual button    2  choose from the list the screen saver desired    3  set the delay after which the screen saver will be shown   4    once the screen saver configuration process is complete  press the virtual button  OK    To disable the screen saver ticking the box NOT SET   DIAGNOSTIC    By pressing the DIAGNOSTIC button it is possible to see the diagnostic information  about the equipment in real time     The information available is the following     FIRMWARE VERSION    SOFTWARE VERSION    MEMORY    Press the MEMORY button  you can FORMAT these memories deleting all files or  DELETE individual data that may be present in the User Memory or Smart Card     The memory available can contain two ty
9.    The duration of the treatment varies depending on the location to be treated  It lasts  about an hour  but a certain time should be calculated to prepare the skin before the  procedure     After the treatment the client can immediately go back to his normal life activities   A mild erythema and swelling may occur disappearing within a few hours    The first effects are immediate and progressive in the following weeks    It is possible to use the radiofrequency at any age     Obviously  the more elastic the skin is the greater the effect will be  Therefore the  elderly will have less evident effects     The results appear gradually over several months  even with a single session  which  may possibly be repeated after a varying time     It is possible to treat all those areas of the body that can present a skin laxity  and  then       The hands  to reduce the laxity of the skin                face  to correct superficial and deep wrinkles around the eyes and on the  forehead  the bags on the eyelids  or the laxity of the upper eyelids  the  wrinkle near the nose  i e   the accentuation of wrinkles between the nose  and mouth   the laxity of the cheek and the area over the jaw with the effect  of  remodelling  the shape of the lips  the laxity of the neck  double chin               arms  to correct the laxity of the lower part     Acne  during its active phase or in presence of scars       The abdomen  to correct the laxity and wrinkles and stretch marks due to  pregnancy  we
10.  PROGRESSIVELY INCREASED ON THE BASIS OF THE  TREATMENT TO BE PERFORMED        32      MATTIOLI                             MAC1935 RF TOUCH    Appendix      DECLARATION OF RESPONSIBILITY    DECLARATION OF RESPONSABILITY    l  the undersigned                                         declare  under my responsibility that     1         not have autoimmune diseases affecting collagen tissues e g  lupus      do not have serious decompensate diabetes    lam not pregnant    lam not wearing a pace maker        do not have Sclerodermia      1 do not have mycete    2  3  4  5  6    do not have moles in the area to      treated  7  8    am not Epileptic   9        have not implants made of metal in the areas to be treated    10    have not Dermatitis do not have in place    SIGNATURE       33      MATTIOLI   ENS iS 5RiN         MAC1935 RF TOUCH    TECHNICAL ASSISTANCE REQUEST FORM  rev  0 of 10 01 2007      to fill it out completely    REFERENCE PERSON TELEPHONE    PRODUCT SERIAL NUMBER PURCHASE DATE DEFECT FOUND APPROV     The merchandise will be sent  together with standard accessories  EX WORKS our headquarters at Via F  Petrarca 80 82 50041 Calenzano  FI      Italy  In case the merchandise is  found damaged  it will be returned to the sender out of warranty and the transport expenses for the merchandise return will be charged to the sender  The packing has to be  appropriate to fragile material shipment and all the electronic parts must be packed with an antistatic product     COMPA
11.  memory to load customized programs   Before switching the device on  make sure that    On request we can provide the user manual in electronic form    Because of security reasons  the only specific software must be loaded into each machine   In case of exchange of software  the machine may immediately stop all its functions   requiring the intervention of MATTIOLI ENGINEERING S P A  technical assistance    RF TOUCH is A class emission  This aesthetic device could cause troubles to other  electronic devices around     MAINTENANCE       se the probes applicators with care  any misuse may affect their performance and  features     nder no circumstances technicians not authorized are allowed to open and or disassemble  the probe applicator  such tampering  besides damaging its characteristics  immediatel  invalidate the right to warranty    The equipment should never be disassembled for cleaning or inspection purposes  the  units does not have to be cleaned internally  and if for some reason the unit must be    opened  it should only be done by specialized technicians authorized by MATTIOLI  ENGINEERING S P A     o not use thinners  detergents  acid solutions  aggressive solutions or flammable liquids to  clean the external parts of the unit and accessories  Using these substances  or misusing  the accessories  will cause the immediate voiding of all warranty rights  as well as  irreparably damaging the unit and the accessories     or optimal use of the apparatus and to ensure i
12.  supply and then the general switch ON    OFF of the generator making sure that the display screen is turned on correctly     The Power Supply and the Generator are connected through a connection multipolar  cable  you need to connect the end plug of the connection multipolar cable into the  connector on the rear panel of Generator  a sure that the connector pins are inserted  correctly  then screw the ferrule to block the connector        10       Ref  5801 2220 RF TOUCH    DESCRIPTION OF THE EQUIPMENT          Rear panel of PROBES  generator Display LCD Rear panel of power  TOUCH SCREEN supply    Monopolar       POWER SUPPLY    Return plate  ELETTRODES    Resistive    Capacitive          11      MATTIOLI                  Ref  5801 2220       RF TOUCH    REAR PANEL OF GENERATOR POWER SUPPLY            UNIPOLAR RETURN BIPOLAR                 o DIT     S                 N       OM           E f     n                j    en     Output connector for Plate connector Output connector for  UNIPOLAR PROBE BIPOLAR PROBE   CAPACITIVE        Socket for       General CONNECTION MULTIPOLAR Powersupply  CONNECTION switch CABLE  MULTIPOLAR CABLE ON OFF of  generator    REAR PANEL OF POWER SUPPLY  RIGHT LATERAL PANEL       Slot for SMART CARD a      insertion EE        Fuses        Power cable supply    Ground              CONNECTION  MULTIPOLAR CABLE    on Power Supply          General switch    J SMART CARD                      n n nn a      MATTIOLI 12  ESGINTTRISNE    Ref  5801 2220 RF 
13.  to EMC measures within the company     The equipment does not generate significant radio frequency energy and is  adequately immune to radiated electromagnetic fields  Therefore it does not  detrimentally interfere with radio electric communications   electro medical  equipment for monitoring  diagnosis  therapy and surgery  office electronic devices  such as computers  printers  photocopiers  fax machines  etc  or any electric or  electronic equipment used in these environments  as long as said equipment  complies with the ELECTROMAGNETIC COMPATIBILITY directive      In any case  in order to avoid any interference problems  we recommend that you  operate the equipment far enough away from critical equipment for monitoring vital  client functions  and that you be careful when applying treatment to clients with  pacemakers        23    Ref  5801 2220 RF TOUCH       the front control ENGINERING S P A  service    panel do not work Control electronic circuit failure centre   TROUBLESHOOTING CHART properly     TE Carefully check the correctness  PROBLEM POSSIBILE CAUSE SOLUTION Faulty connections in circuit output    and integrity of the output  applied by operator  ti  Supply cable plug not correctly   Check for proper functioning connections     inserted in the wall receptacle  of the wall socket Probe applicator cable cut or    The device does j   d                Plug      properly        connect   PROPER ea e handle applicator showing  not emit the  cable to the connector of
14. DELETE you can proceed to the format memory as    It allows loading the required program choosing between described in the section MEMORY  DELETE  e the list of the CLIENTS CARD 3  select OPEN to open the protocol   e       list of personalized PROTOCOLS At this point is possible    CARDS    ToSTART the treatment    In this section is possible to load a CLIENTS CARD stored      O CHANGE parameters ok ne treatment    1  Select the type of memory  USER MEMORY or SMART CARD  from which you e      SAVE the treatment parameters following the procedure described in  want to choose the card SAVE     o selecting FORMAT you can proceed with the format memory as BACK  described in the section MEMORY   FORMAT    Pressing the BACK button it is possible to work backwards or returning to the    2  select GO TO THE LIST OF USERS           previous operation or coming back to the main screen     3  touch the desired card    HELP      Selecting DELETE you can proceed to the format memory as  described in the section MEMORY   DELETE Pressing the button HELP after selecting a particular task you want to perform  you   4  select OPEN to open the card  can get directions  suggestions about the selected operations    To CHANGE the data of the card proceed as described in Section MODIFY a CARD  SETTING    At this point is possible    P            This section is necessary to edit and save to the internal memory      basic settings to            START the treatment be recalled automatically every ti
15. MATTIOLI    Contact an MATTIOLI ENGINEERING S P A  service  Control electronic circuit failure  ENGINEERING S P A  service Possible fault in unit current centre     centre generator circuit     Fuse or fuses damaged or blown     Contact an MATTIOLI  ENGINERING S P A  service  centre     Faulty keys or buttons  Contact an MATTIOLI    The LCD display Faulty components on the  doesn t turn on  electronic control card     Ref  5801 2220 RF TOUCH                                                                                                                      Max power density of capacitive electrodes 42 46 W cm     Output channels 2 indipendents  TECHNICAL SPECIFICATIONS  Stored programs 12 15  GENERATOR RF TOUCH Storable programs on the user memory 100       100V  24    16     through  SUI DY Power Supply RFPS1 o RFPS2 Storable programs on Smart Card 100  LCD backlit display to show and control all operating Colour Touch screen  5 7    Storable Client Cards on the user memory  Depending on the number of  parameters 320  240 pixel characters used to compile  Programmable treatment time Up to 60 minutes Storable Client Cards on Smart Card the card  Peak power 300 Wpk max   unipolar  Integrated user memory  Type of secondary memor  Probe emission frequency 455 KHz   1090 i d d  Smart Card  Bipolar  Standard handsets Room temperature  10   40  C  Unipolar       ati  30   85  96 without  Resistive  for Bipolar  Conditions for use Relative humidity          Type of electrode  Capaci
16. NY       Technical assistance conditions and rules     A necessary condition for the merchandise shipment is the above stated FORM  which should be filled out completely and included to the shipment  along with a detailed  TECHNICAL REPORT     Otherwise we will not be able to provide for the problem resolution   Stamp and signature for acknowledgement and acceptance  Date of request    MATTIOLI ENGINEERING S P A  Via F  Petrarca 80 82 50041 Calenzano  FI    Italy         MATTIOLI       Ex  izkaiv         Ld    MATTIOLI     ENGINEERING    MATTIOLI ENGINEERING ITALIA S p A   Via Petrarca  80 82   50041 Calenzano         Italy   Tel   39 055 88 22 47 e Fax  39 055  88 74 879    e mail info mattioliengineering com e website   www mattioliengineering com    
17. TES    The warranty does not however  include the replacement of the equipment     The warranty does not cover any malfunction or damage caused by       incorrect connection and installation     PRELIMINARY NOTES      Incorrect use due to non compliance with instructions contained in this manual      The installation of the device does not require any special care  is therefore simple and      improper or inadequate maintenance  USE immediate     use of the machine in environmental conditions which do not conform with those     The selection of the SMART CARD is possible only if previously inserted into the slot   specified for the product      To prevent erasure or formatting of SMART CARD  confirmation is required         MAINTENANCE    unauthorized opening of the outer casing    For an optimal use of the device and to guarantee its maximum performance  it is        TM recommended to perform maintenance at the correct time and suggested ways     tampering or unauthorized modifications       use of non original accessories  CAUTIONS    PRELIMINARY NOTES    The customer is liable for all damage caused by inadequate packaging of the material     MATTIOLI ENGINEERING S P A registered offices provide the warranty     Should you need to return the goods then please note the packing instructions as Keep the original packaging of the unit  it will be needed if the unit is returned to the  follows  Enclose a copy of the purchasing receipt  company   You should insure the postal pack
18. TOUCH    HOW TO USE THE DEVICE    This section provides important indications about the correct utilization of the  aesthetic equipment for radiofrequency unipolar and bipolar treatments RF TOUCH     All the control functions and the machine itself are handled and co ordinated by a  microprocessor  apart from making pre memorised programmes available for  application  the microprocessor ensures that the machine can be personalised and  operated ina highly safe and efficient manner     Interfacing allows for the operator to communicate with the unit by means        large   clear graphic backlit liquid crystal display screen  LCD  through which all operational  messages required by the operator  work status during operation  and errors are  visualised     The following paragraphs illustrate the operations that have to be carried out by the  operator to better exploit the capacities and the technical peculiarities of the  equipment RF TOUCH     We discuss the different options  the selection of a pre stored for the setting of a  specific treatment  until the determination of the correct working parameters for an  application  custom      FUNCTIONING    RF TOUCH exploits the transfer of heat generated by the device  that penetrates  deeply into the skin tissues reaching the derma and the adipose tissues     The increase of the tissue temperature stimulates the fibroblast to produce new  collagen and new elastin     This process improves the signs of aging and makes skin more rela
19. age  o not use the equipment in places where it might get wet       Before operating the machine carefully check the correctness of the connections    Before sending the machine back for suspected malfunction  we recommend that first according to the instructions     you carefully consult sections regarding MAINTENANCE and TROUBLESHOOTING of       the manual  asa large part of the problems        faults are usually due to inadequate o not use accessories other than the ones provided  they might damage the unit  causing  maintenance or small technical problems which can often be easily solved by the user the warranty to become void  In case you have any problems or difficulties with  himself installation  contact MATTIOLI ENGINEERING S P A  technical support    A simple call to MATTIOLI ENGINEERING S P A technical department may prove to be f using the same extension for the unit and other units  make sure that the total current  the solution to the problem  being absorbed by the connected units  does not exceed the max current allowed for that    type of cable and that  however  it does not exceed 15 A   When re packing the equipment for return to the manufacturer  proceed as follows          MATTIOLI   Es  riziriv      Ref  5801 2220 RF TOUCH    USE    he protocols are stored in the permanent memory of the machine  These protocols can be  edited but not possible to save any changes    The protocols preloaded on the machine cannot be deleted    It is not possible to define a 
20. allow the machine to work in safe conditions  In case of non compliance with this  indication  MATTIOLI ENGINEERING S P A  will not be responsible for any accidents   Before starting the treatment delivery  the operator shall check that the client has  removed from their body any metal objects  in order to avoid any dangerous phenomena  of radiofrequency coupling   Its important to pay the attention of the operator to the necessity to verify the  correctness of the electric installation of device before activating the supply switch    To turn the device in properly on  observe the following indications    1  Placethe Generator and the Power Supply on horizontal and stable surface    2  Connect the Power Supply to the Generator through the connection multipolar   cable   3  Plug the power supply cable into the connector on the back of Power Supply       MATTIOLI   Es  riziriv      4  Connect the power supply cable to the wall socket    5  Turnon the general switch ON   OFF on the back of Power Supply    6  Turnon the general switch ON   OFF on the back of Generator   It is importafit that the operator verifies that the surface of the inserts  electrodes is intact  before switching on mains switch and starting the session   It is advisable to suspend the treatment if it were to appear some disturbances during its  emission   Before every treatment  it is recommended to clean with caution all of the accessories and  the parts of the equipment that have been to contact with the c
21. ator Weekly    Operator Weekly    Do not use compressed air or aerosol products  any dripping any liquid can affect  device operation     In case of accidental penetration of liquids or foreign materials within the housing   does not open the device to remove the spilled material but contact the technical  assistance service and does not operate the equipment     Cleaning should be carried out using non abrasive cloth with non corrosive sanitizers   Working place and storage    The device has been engineered to work in proper working places like the rooms  destined for beauty treatments     Environments with high thermal excursions  high humidity percentage  dripping of  water or other liquids  dusty atmosphere or polluted by chemical agents  inflammable  materials or gas  are inadequate both to use or store the device in     The device can be used in the presence of other devices that normally are installed in  the abovementioned rooms     The use of the device in environments contaminated by resistive or capacitive  radiofrequency  electromagnetic fields  mobile phones  etc    ionizing radiations   mechanical and or sonic vibrations or anyway in the presence of devices that usually  are not used in medical  physiotherapeutic and beauty environments and that are not  comply with the requisites of electromagnetic compatibility can provoke  malfunctioning of the device  making it dangerous for the user and the client        RF TOUCH    Maintenance and checks    The trials and 
22. cleaning of  the handles applicators  in order to assure the best operative conditions  to  guarantee an efficient treatment and safety of the person being treated     Regular maintenance of the equipment shall be carried out each time before you  operate the equipment in order to verify its integrity and safety     When cleaning the outer part of the equipment  make sure to use a soft  clean cloth  dampened with luke warm water or very mild non inflammable detergents     Do not place objects on the machine that produce heat or containing water or other  liquids     Do not use compressed air or aerosol products  any dripping of liquid can impair the  functioning of the equipment     In case of accidental entry of liquids or foreign materials inside the casing do not try  to open the device to remove penetrated material but contact your service agent and  does not use the equipment     The device must be periodically sanitized     The probes and in particular the head of the probes should be periodically cleaned  using water and denatured alcohol     Store the handles applicators with care after every treatment session     For information on original accessories and spare parts please contact MATTIOLI  ENGINEERING S P A  authorised dealers     The operator is herewith informed that it is necessary to carry out periodical  maintenance of the applicators and particularly       inspect the electrode surface to verify that there are no cracks  where conductive  gel may enter the e
23. csscscesscesccsscesecsces 9          SEEE AE e n ra a                19  DEVICE                    lt                                9 MUSIC NK 19  UNPACKING          eeeeseen Rennen aee eee tate etat oeeteeteosoesoeeeeoeseeseeoeoeoeeoeonoesooouoouoesnooun 9 LANGUA GE                                                               cCO      19  SETTING UP    9                                                           19  ACCESSORIES                     ae be         9 DIAGNOSTIC cececcecceccecceccescescessessessessesscsscsscaseescussascsscassassasasasesscasesseaseaseaseaseaseaseasenees 19  SOININ ON      10 MEMORY                      19  DESCRIPTION OF THE EQUIPMENT                           11 MAINTENANCE SRM 20  REAR PANEL OF GENERATOR  aiiiiriiotiterevoooooooonooas one oon oo oen                            l   TROUBLESHOOTING   cette 23   RIGHT LATERAL                                                    12  POWER 5                            haah e a a A n n A A A A AA A A AA AAA AA AAAA A a aa aa aan 12 ELECTROMAGNETIC INTERFERENCES                                           23  REAR PANEL OF POWER SUPPLY      sssssssssssssssrsssnsssnrssnnsnnnnnsnrnsnnnnnnnnnnrnennnennrnsnrnenneenns 12 TROUBLESHOOTING                               24  HOW      USE THE DEVICE                            13 TECHNICAL SPECIFICATIONS    cccccccsccceccecceseccescescecsesssceccescessessecsccecsessessacsecessesseees 25   UINTIIN emettet eret eld 13  SILIO                    14 APPENDICES             
24. e highest quality     The equipment were planned and built in manner that their use  if it happens at the  conditions indicated  doesn t compromise the health and safety of the clients  of the  users and of third  taking into consideration the benefit to the client     The use of this device is reserved to the aesthetic operators that  by their training   provide assurance of proper use and safety for the client     The aesthetic operator  in fact  should be qualified to be able to use such equipment   and he should have passed an adequate training  or should operate under the control  of a adequately qualified professional figure to the use of the equipment  in order to  guarantee safety conditions to the person who undergoes the treatment     A special intervention is not required in the event of failure of the device  but just a  normal maintenance repair        RF TOUCH is an aesthetic device that delivers treatments of radiofrequency  with the  aid of a probe that allows the delivery of the treatment     The use of RF TOUCH is reserved for aesthetic operators who  by virtue of their    professional training  offer the guarantee of the appropriate use and in total safety  for the client     The aesthetic operator  in fact  should be qualified to be able to use such equipment   and he should have passed an adapted training  or should operate under the control  of an operator adequately qualified to the use of the equipment  in order to  guarantee safety conditions to the c
25. e manual in the    section MEMORIES    ELIMINATE   o RESULT    4  select OPEN to open the card      Number of PERFERMED TREATMENTS    At this point is possible if necessary to change the parameters of the card before    o Number of PROVIDED TREATMENTS beginning the treatment        16    Ref  5801 2220 RF TOUCH    MODIFY a CARD  TOLLBAR  1  Select MODIFY  Down on the screen  there are a series of buttons having service functions  such as     o its possible modify all the data previously entered    5  1                          HOME  which allows you to return      the home screen from any menu       MANUAL  which displays the default program on each of the output  channels  with the ability to personalize and save it on a secondary storage  media available  user memory  Smart card      3  acton its commands to make the changes  and you are finished  click ENTER to  confirm     o inthe event of changes to PROTOCOL  will appear on the full list and    the scroll bar  selecting the new item that will replace the previous   LOAD  which allows you to load the selected channel a program in one of the    secondary storage media machine  user memory  Smart card      4  Tothe question  Changes made  Save   Click Yes to save the data entered             BACK  which allows you to go back to the screen immediately prior to the    5  select GO TO TREATMENT to start treatment  selected     At this point it s possible    HELP  which allows you to get directions and suggestions on the operat
26. ed  for 15  minutes    This treatment allows to create a vasodilatation which favors the microcirculation   the collagen synthesis  and notably improves the oxygenation of tissues     It is recommended to subsequently apply an ultrasound unit with gel for 10 minutes   using the face applicator or body plates which  thanks to the mechanical  thermal and  chemical effects  prepares the tissue causing the permeability and temperature  increase of the cellular membrane  as well as the acceleration of the tissues particles     Ref  5801 2220 RF TOUCH    INTENDED USE    This pre treatment system allows the subsequently applied radio frequency  to act  deeply  completely and in a long lasting manner     Note  IT IS RECOMMENDED TO HAVE THE CLIENT SIGN THE FOLLOWING  DECLARATION BEFORE STARTING THE RF TOUCH TREATMENT CYCLE  Appendix E      IN GENERAL    MATTIOLI ENGINEERING S P A  has recently developed a complete series of  apparatus  accessories and equipment  designed and manufactured according to the  highest standards of quality  making use of the latest technology and fully adhering to  current directives and norms     Particular attention has been paid to the design  easy operation  function and safety  of the equipment and the final result is this modern  compact unit  which offers an  extremely logical operative sequence supported by a clearly legible display      A wide range of aesthetic applications  and guaranteed client and operator safety  ensure that equipment is of th
27. ed in the strip using the lateral scroll bar    3  choose the required TREATMENT PROTOCOL    4  click on OPEN    At this point is possible    e To START the treatment  following the procedure STARTS       To CHANGE the data of the treatment  proceeding like guide in MODIFY     e To SAVE the parameters if necessary changed proceeding like guide in SAVE     MODIFY  The following parameters can be modified   o MODE  o POWER  o DURATION     HANDLE    To change the MODE parameter select simply the arrow and choose the type of  operation     e CAPACITIVE     BIPOLAR    Change the POWER field just select it and use the arrow keys  you can choose from  three levels of intensity        LOW  percentage of power by 0 32   e MEDIA  percentage of power by 32 66      ALTA  percentage of power by 66 100     Once you start treatment  you can change the percentage of power manually using  the   and       Change the DURATION parameter simply checking the arrows   Change the DURATION parameter simply selecting the relative arrows   At this point is possible   e To START the treatment  following the procedure START      To SAVE the parameters if necessary changed proceeding like guide in SAVE   START  To begin the treatment   1  click the button START   2  position the probe on the part to treat   3  the TIMER will start count backwards   4  to discontinue treatment click the PAUSE button   5    to resume the treatment click on the button CONTINUE  otherwise to end the  treatment click on STOP  
28. ight loss  age     Immediate benefits    The cellular function and the blood circulation are therefore improved  the lipolysis in  fat skin is stimulated and an increase in the collagen synthesis  the total volume of  collagen fibers  is registered        Consequently  an important tissular turgor  and a significant oxygenation of the  tissues are registered thanks to the elimination of toxins     The smoothness of the tissues is immediate     The results will show gradually over several months even with a single session  which  may be repeated after a variable time     To be combined with    The treatment with RF TOUCH has an excellent synergy with the equipment LIFT SKIN   the electro porator which allows the transmission of the trans dermal active  ingredients to treat any type of imperfection on the face and body of men and  women     The electro poration should start 3 days after treating the client with radio   frequency     TREATMENT PROCEDURE    PREPARING THE CLIENT    The treatment room must have a comfortable temperature in order to avoid shivers  or muscular tremors     The client must be in as comfortable position as possible  it is recommended  like in  other cases of physical treatment  to explain to the client  prior to treatment  which  sensation is to be expected     Also ensure that you are aware and able to follow all indications relating to safety   PRELIMINARY TREATMENT PROTOCOL    Before every face and body treatment  the use of a laser unit is recommend
29. ion       TO START the treatment  following the procedure STARTS  currently selected     e TO CHANGE the treatment parameters  proceeding like guide in MODIFY    SETTINGS  which allows you to define the working conditions of the machine     At the end of the treatment referred to the selected card  the number of TRAT  MANUAL    PERFORMED SESSIONS will be automatically increased   In this section is possible to make a MANUAL PROTOCOL     Once reached the number indicated on patient s card  it will appear a window that  will indicate TREATMENTS COMPLETED FOR  client s name   In MANUAL PROTOCOL is possible     Close the window with OK and continue choosing the required function  e modify the data that appears by manually selecting the desired values    PROCEDURES e create and use programs in the MANUAL emission mode    Pressing the key PROCEDURES is possible to load  To set the values of the treatment will need to follow the instructions described in  paragraph MODIFY the parameters     1  the USER MANUAL of the device RF TOUCH  MM    At this point it s possible     a  select relative taste  e To START      treatment  following the procedure START     b  select the topic and wait          SAVE the customized protocol proceeding like guide in SAVE   2  the GUIDE VIDEO   a  Select relative taste  b  selectthe title and wait    To end the session and go to the main menu click on BACK        Ref  5801 2220 RF TOUCH    2  touch the desired protocol from the list  LOAD    o Selecting 
30. is symbol means that the product should not be disposed of as  domestic waste      Table container external dimensions  Width x The user must dispose of scrap equipment by taking it to a recognised electrical and  Height x Depth  Power Supply 23 8x10x16 cm  electronic recycling centre   Weight Power Supply 5 6 Kg               upon request         MATTIOLI   ENS iS trive    Ref  5801 2220 RF TOUCH    Table 1    Label   Meaning Label   Meaning                Product certification    Manufacturer and date of manufactured    Manufacturer    This label is placed near equi potential  connection placed on the rear panel of  Power Supply     This label indicates that a radiofrequency  output signal is present  placed near the  applicator connectors     Type BF equipment    Attention  read the accompanying documents of the  product       Table 2  See the user manual    The product must be dispose of as    electronic waste     not  as    domestic waste       Input characteristics    Main power supply     Input voltage to the device    Fuses    Absorbed power   Input power of the device    Emission frequency   Input frequency of the device    Business model of the equipment    Serial number    Output characteristics of the device  Output power of the device    Output frequency of the device    Output voltage to the device          27       Ref  5801 2220 RF TOUCH    Appendix C   LIST OF BIPOLAR PROTOCOLS    Teleangiectasia on the face    Wrinkles  on the forehead     neck skin relaxati
31. ith these warnings may result in dangerous electrical discharges that could cause  injury operators and compromise the functioning of the unit    For the safety of the client and the operator  the following obligations must be respected   Avoid using extensions   Avoid using double or triple plugs   Position the unit away from sources of heat   Position the power cables so as to avoid they are crushed or stepped on   Do not keep liquid containers near the unit     VN VN ON    Radiofrequency treatments must be delivered under full control of the operator to   conscious  clients  who can interact with the operator during the emission of the  electrical stimulations provided by the equipment   The operator is responsible to verify that the emitting electrode adheres completely to  the treatment area  in order to avoid collateral emission to other areas  In order to ensure the functioning of the machine in conditions of absolute safety for the  client  the operator must pay attention to the necessity of a periodic maintenance  ever  2 years  of the equipment  MATTIOLI ENGINEERING S P A  authorized personnel should  carry out such operations   It absolutely forbidden the use of the device in the presence of a flammable anesthetic  mixture and oxygen rich environments  In case of non compliance with this indication   MATTIOLI ENGINEERING S P A  will not be responsible for any accidents   It is absolutely forbidden to cover the ventilation slots of RF TOUCH  such an action may  not 
32. lectrode       verify that the cable and the connector of the applicator are not damaged     Do not spray  nor pour liquids on the external case of the radiofrequency equipment  RF TOUCH  nor on air splits or near the LCD touch screen display     Do not dip the unit in water     Ref  5801 2220 RF TOUCH    Do not dip the applicators nor the cables in liquids  as it may cause deterioration of  electronic components and damage electric isolation of the cables     After cleaning the outside of the box  perfectly dry all parts before starting the unit  again     Do not under any circumstances disassemble the unit in order to clean it or inspect it   there is no need to clean the inside of the RF TOUCH unit and  in any case  this    operation must only be carried out by specialised personnel authorised by MATTIOLI  S P A      To make correct replacement of fuses on the device  follow these guidelines     1  use a screwdriver to open the fuse holder tank  making sure to insert the  screwdriver into the recess made on the pan fuse holder and prying outward    2  remove the fuse holder structure by sliding it along the guide  3  remove the fuses inserted and replace them with as new    4  insert the fuse holder into the fuse holder tank structure by sliding it along  the guide    5  close plastic door of the pan fuse holder     For optimal use of the device and to ensure its best performance  it is recommended  to execute properly the maintenance in time and in the recommended manner 
33. lient     INDICATIONS    The apparatus for radio frequency treatments for aesthetic use RF TOUCH is applied  on the following defects         Body tissue relaxation       Cellulite       Fat       Stretch marks        Atone of breast muscles       Aging of face and neck tissues       Wrinkles       Scars       Tissue gaps        Asphyxial skin        Acne    Ref  5801 2220 RF TOUCH    CONTRA INDICATIONS       Autoimmune diseases affecting collagen tissues  ex  lupus      Serious uncompensated diabetes      Pregnancy      Holders of pacemakers       Sclerodermas      Moles       Mycete      Treatment on central area of breasts    PRELIMINARY NOTES    DEVICE COMPONENTS  The aesthetic equipment for radiofrequency RF TOUCH is composed of     GENERATOR       POWER SUPPLY   CONNECTION MULTIPOLAR CABLE  identified with RFPS1 for  230Vac and with RFPS2 for 115Vac     IMPORTANT  The serial number is unique  The serial number written in the power  supply must be equivalent to serial number written in the generator     UNPACKING    The aesthetic equipment for radiofrequency RF TOUCH is specially packaged for  transport in a single pack complete with filling which has been specifically studied for  safe transportation and storage     To remove the equipment from the pack  place the box on a smooth  flat surface   Open the top of the box and remove the polystyrene filling  Be very careful when  removing the contents of the pack     The unit and accessories are wrapped in transparent sheet
34. lient  particularly the  electrodes   It s strongly advised not to hold the device on in state of start without using the probe  it  could overheat     Ref  5801 2220 RF TOUCH    MAINTENANCE      For safety reasons before carrying out any maintenance or cleaning the unit  YOU MUST    turn off the equipment with the power switch at the back and unplug the socket  connected to the mains       It is recommended to clean with caution all of the accessories and the parts of the  equipment that have been to contact with the client      115 important that the operator periodically carries out maintenance of the applicators   especially       checking the electrode surface to verify that there are no cracks  where from  conductive liquid may enter      checking that the cable and the connector of the applicator are intact      The cleaning and disinfection must be done systematically before the treatment which  subject the client      Do not spray  nor pour liquids on the external container of the device  on ventilation slots  of device  on the LCD touch screen display  If that happen  inspect the device  MATTIOLI  ENGINEERING S P A  shall not be responsible for any damages arising from the use of the  equipment non in compliance with the above conditions      Always control sometimes the integrity of the cable  of the connection multipolar cable  and of the probe applicator connector  they must not be damaged or worn      Itis advised that personnel with technical preparation substi
35. me the machine      TO CHANGE the treatment parameters Pressing the SETTING button appear the screenshot where you can select   To START the treatment  follow the procedure START     SOUNDS  To CHANGE the treatment parameters  follow the procedure MODIFY  e MUSIC  PROTOCOLS e LANGUAGE  In this section is possible to load a PROTOCOL choosing among those custom  e DISPLAY  1  Select the type of memory  USER MEMORY or SMART CARD  om which you want e DIAGNOSTICS    to ch th t       choose the protoco e MEMORY    o Selecting FORMAT you can proceed with the format memory as  described in the section MEMORY   FORMAT             8      MATTIOLI   Es   riziriv      Ref  5801 2220 RF TOUCH    SOUNDS    By pressing the button SOUND is possible to select the sound settings of the  equipment     1  click on the SOUND icon    2  enable disable the KEYBOARD CLICK ticking each box    3  enable disable the sound of END TREATMENT ticking each box   4  enable disable sounds WARNING ticking each box   5    Once you know the audio settings  press the OK button to enable the settings     MUSIC    Clicking on the MUSIC icon you can select the option to listen to the music in the  background during treatment     1  selecta song in the list of SONGS AVAILABLE   2  upload it to the LIST OF LISTENING using the RIGHT ARROW    o to remove a song from the LIST OF LISTENING select it and use the  LEFT ARROW pointing towards     3  Onceloaded the tracks you want to click on the desired TOOLBAR     LANGUAGE 
36. ng it with both hands on the curved profiles of the lid     he perfect functionality of the device is guaranteed in accordance with the rules of  installation and of use included  only with original accessories and spare parts     f there are problems or installation difficulties  please contact the MATTIOLI ENGINEERING  S P A  technical assistance department    Before connecting the cable to the mains plug  check that the equipment wasn t damaged  during transport  Ensure that the power supply specifications on the mains socket  correspond with the information on the label attached to the back of the unit     O NOT INSTALL the RF TOUCH unit near heat sources  nor in direct sunlight   Do not use mobile phones near radio frequency devices when they are in use  as they may  cause electromagnetic interferences     Ref  5801 2220 RF TOUCH    USE       The electric current that powers the unit is          DANGEROUS  Before connecting or  disconnecting the power cable from the connecter on the Power Supply  make sure it is  plugged out from the mains socket     he power cable has an earthed plug for safety reasons    Only use with a mains socket suitable for use with earthed systems    The equipment should only be connected to electrical systems that fully comply with  standards    If using extension cords verify the presence and the integrity of the protective conductor  to earth    Connect the Power Supply directly to the wall socket without using extensions  Failure to  comply w
37. number of sessions suggested to evaluate the effectiveness of  the treatment  since they are related to the power delivered to the client undergoing  treatment  It is a task of the physician to decide the number of treatment sessions which  subject the client according to the specific requirements of the case  in order to ensure to  the client himself the execution of an effective treatment in time and place in conditions  of absolute safety    Always control sometimes the integrit licator    of the cable and of the probe a    connector  they must not be damaged or worn     The Smart Card has to be introduced keeping the golden chip facing up    A new Smart  Card has to be initialized using FORMATTING before being used    In case of selection of this type of memory if the card is introduced in wrong way      is not  formatted or results not correct  a warning window will appear with the information  about the error  Close the window clicking OK to continue    SMART CARD option is visible  and therefore selectable  only if the smart card is properly  inserted in its slot  In case of lacked insertion of the Smart card in its slot or Improper  insertion  the option button SMART CARD is not visible  for which a possible selection  does not involve any action    The selection of programs to be loaded takes place by default in the user memory  that in  cases of non presence of the Smart card  due to its lack or to an improper insertion in its  slot  is the only support of available
38. on ad  wrinkles e rughe     Acne scars    Active acne  E    Outcomes acne scars    Face and neck skin laxity    Face skin laxity    medium  45mm        28      MATTIOLI                     Ref  5801 2220 RF TOUCH         Body skin laxity    Cellulitis  Solar lentigo  Stretch marks    Post lifting maintenance    m m m    small  25mm     Note  IT IS RECOMMENDED TO START THE TREATMENT WITH POWER THAT DOES        EXCEED 50   WHICH WILL THEN BE PROGRESSIVELY INCREASED ON THE BASIS OF THE  TREATMENT TO BE PERFORMED        29      MATTIOLI                  RF TOUCH       Ref  5801 2220    Appendix D     LIST OF UNIPOLAR PROTOCOLS        Facial muscles hypotonia    Small 30 mm       Localized facial adiposity    Small 30 mm    Face cutaneous relaxation  Face dermo care  E    Small 30 mm    Big 50 mm    Edematous lipodystrophy    Big 50 mm    Fibrous lipodystrophy  Big 50 mm    Sclerotic lipodystrophy       Big 50 mm         MATTIOLI                     Ref  5801 2220 RF TOUCH    Abdominal localized adiposity    Magnum 80 mm       Gluteal localized adiposity    Magnum 80 mm    Hips localized adiposity    Magnum 80 mm    Thigh localized adiposity    Magnum 80 mm    Magnum 80 mm         Breast muscles hypotonia       Magnum 80 mm          XXL 70 mm    Body cutaneous relaxation    Breast cutaneous relaxation       E        Body muscles hypotonia            MATTIOLI   Exact            Note  IT IS RECOMMENDED TO START THE TREATMENT WITH POWER THAT DOES        EXCEED 50   WHICH WILL THEN BE
39. onfirm the name  otherwise click on BACK to get back to      6  Tothe question  Changes made  Save   Click YES to save the data entered   the previous screen           At this point it s possible   To start the program saved  proceed how described in the section START        To START the treatment  clicking on GO TO TREATMENT         then  following  CLIENT CARD the procedure START     Pressing the button CLIENT CARD it is possible to OPEN or REMOVE CLIENT CARD e To CHANGE the treatment parameters  clicking on MODIFY and  then   previously saved in the memory or CREATE a new CARD  proceeding like guide in MODIFY   CREATE a CARD At the end of the treatment referred to the selected card  the number of TRAT     PERFORMED SESSIONS will be automatically increased     1  Push the button CLIENT CARD   Once reached the number indicated on patient s card  it will appear a window that    2  push the button NEW  will indicate TREATMENTS COMPLETED FOR  client s name    3  select the memory support on the window will appears on the screen  Close the window with CLOSE and continue choosing the required function   4  fillin the following fields  OPEN a CARD     SURNAME  mandatory  1  click the button CLIENT CARD      NAME  mandatory  2  choose the memory from which to load the card  between the USER MEMORY or  o BIRTH DATE SMART CARD   o TREATMENT VALIDITY 3  touch the card to open and the written will be emphasized in dark blue   o PROTOCOL o if you want to use the key ELIMINATE consult th
40. ong with checking the integrity of the part connected to mains     The expected work life of this equipment is 10 years        22    Ref  5801 2220 RF TOUCH    TROUBLESHOOTING    The aesthetic equipment for radiofrequency unipolar and bipolar treatments RF  TOUCH has been designed and manufactured using highly advanced technology and  first class components for reliable and efficient performance     However  should you meet with any operational problems  we recommended that  you consult the following guide before contacting any of our authorised service  centres     If any of the following situations occur  disconnect the machine and contact MATTIOLI  ENGINEERING S P A  authorised service centres     e the cable set or rear supply panel show signs of wear and tear or are  damaged     e the liquid has entered the equipment     e the equipment has been exposed to rain     ELECTROMAGNETIC INTERFERENCES    The aesthetic equipment for radiofrequency mono and bipolar treatments RF TOUCH  has been designed and manufactured according to the ELECTROMAGNETIC  COMPATIBILITY DIRECTIVE 2004 108 CE with the aim of providing adequate  protection from harmful interference when installed in homes and health  establishments     All required measurements and tests have been carried out in MATTIOLI  ENGINEERING s internal Testing  Measurement and Inspection laboratory           in  addition to other external specialised institutes  The customer  upon prior request   may view the reports relative
41. pes of data  CLIENT CARDS and the  CUSTOMIZED PROTOCOLS     FORMATTING the memory  1  Select the FORMAT button   2  inthe window that appears select   o YES to confirm formatting    o           cancel the formatting       19    Ref  5801 2220 RF TOUCH    MAINTENANCE    Formatting the Smart Card must necessarily be done when you insert a NEW CARD  that has never been used     It can also use the FORMAT function once the selected Smart card as a secondary  memory area to erase it completely  thus making it available  for example  for use on  a different machine     ELIMINATION data in memory    To delete the CLIENT CARDS    1  select GO TO THE LIST OF USERS    2  selectthe data to be deleted  once selected will be highlighted in blue    3  click DELETE    4  a window will appear where you will be asked to select   o YES to confirm the deletion  o Notocancel the deletion   To delete the PROTOCOLS    1  select the desired protocol in the list    2  click DELETE    3  a window will appear where you will be asked to select   o YES to confirm the deletion  o      to cancel the deletion    If the Smart card is not properly inserted into the slot  you can not format it  In this  case  is loaded with default screen of any programs stored in the user  which will be  the only support available for secondary storage any formatting        The aesthetic equipment for radiofrequency mono and bipolar treatments RF TOUCH  do not require special maintenance  apart from a periodic servicing and 
42. rough an electrode covered in an insulating ceramised material  available  in different dimensions depending on the area to be treated  mobilizing the  charges  ions  in the subcutaneous tissues     gt  bipolar type electrodes  the transfer is made through a bipolar  non isolated   electrode mobilizing the charges  thus making it possible to concentrate  them on a surface level     13    Ref  5801 2220 RF TOUCH    The anatomical zones are     BEST USE     HEAD  After having installed and correctly positioned the machine as per the instructions  described in the previous sections  to turn the device RF TOUCH in properly on  observe the   NECK  following indications      SHOULDERS  1  Connect the Power Supply to the Generator through the connection multipolar   CHEST   cable      ARMS   2  Plug the power supply cable into the connector on the back of Power Supply                           FOREARM   3  Connect the power supply cable to the wall socket  230          BACK  4  Turn on the general switch ON   OFF on the back of Power Supply to  ON       ABDOMEN  5  Turnon the general switch ON   OFF on the back of Generator  to  ON       LUMBAR ZONE  This action enables the operation of RF TOUCH  determining the ignition of the backlit  LCD display that indicates the condition of the apparatus ready to operate    GLUTEAL  The LCD display will light up showing the logo and the name of the equipment    LEGS  By pressing the SKIP button on the screen  appears the main page that allows 
43. s of polyethylene  protection and contains the following       n 1 user manual          n 1 mains power supply cable     n 2 spare fuses  see technical specifications        n 1 unipolar  capacitive  probe  equipped with electrodes of various diameters  see  paragraph  accessories         n 1 bipolar probe  equipped with electrodes of various diameters  see paragraph   accessories          n 1 return plate for unipolar RF      n 1 bottle of conductive cream 1000ml     n 1 pen for touch screen display      n 1 Smart Card     Check the package contents  If some element is missing  immediately contact  MATTIOLI ENGINEERING S P A  authorized dealer     SETTING UP  Installation of the radiofrequency aesthetic equipment RF TOUCH is fast and simple   You must place the device on horizontal and stable surface   The following environmental conditions are ideal when installing the equipment      room temperature  from  10   to  40  C      humidity level  from 1096 to 8096 without condensation      avoid direct exposure to sunlight  chemical products and vibrations   ACCESSORIES    The device can be used with the following accessories     Accessories Supplied Optional    Power cable plug shuko            Pair Spare Fuses   a1        User manual in DVD   a         Bipolar Probe   kit inserts electrodes diameters 25    1  45 70 mm  Unipolar Probe   kit inserts electrodes diameters 1  30 40 50 60 70 80 mm       Ref  5801 2220 RF TOUCH    Return plate for unipolar RF    1    Smart Card     
44. skin  releasing heat to the surrounding tissue     This allows to  heat up  the collagen  with an effect of contraction  which is reflected  in the skin relaxation  increasing the tone with a lifting effect     The degree of the thermal effect depends on the conductivity characteristics of the  treated tissue  For this reason  the tissues with increased impedance  such as the  adipose one  generate more heat  resulting in a greater thermal effect     The principle on which the radio frequency is based is therefore the increase in  temperature that occurs in the treated areas  transporting energy to the deep dermis  and subcutaneous layers     This will improve cellular function and blood circulation  stimulate lipolysis of  subcutaneous fat and increase collagen synthesis     Where it acts and effects  Radio Frequency treatments act on the tissues and produce the following results    gt  Three dimensional contraction of collagen fibres  with a 360   volume effect  Drawing of liquids up to the surface  Improvements in the micro circulation system  Removal of toxins  Synthesis of new collagen  Tightening of tissues  Smoothing of tissues  lifting effect  Restructuring of the skin    Increased skin density in the short term    Y    ON ON ON ON ON ON WV    Oxygenation of tissues    Ref  5801 2220 RF TOUCH    General applications modalities in aesthetic    The treatment can be performed on all skin phototypes and even during the summer  because sun exposure is not contraindicated  
45. son     L  Check the condition of the cable and the plug  replace if worn     Certain verifications may be carried out by personnel who work on the device  while  the other  more technical  must be carried out by trained and authorized by the  manufacturer in the written form     To ensure the safety and the correct operation of the apparatus must comply with  the following program of maintenance     OPERATION BASIS  EACH  EXECUTOR    ca    Check power supply cable       X             X      WA ti iii     Checkprobecabl      x      X                  inspection of any damage to             ams      x  fe    Instrumental verification of the EN  it         Le   Instrumental verification electrical                   dL         TOUCH is      electronic device  therefore  to ensure its safety the periodic  maintenance must be carried out exclusively at the laboratory at the laboratory and  authorized by the manufacturer in the written form        21       Ref  5801 2220    Modality of Hygienisation    The device must be sanitized periodically  Disconnect the power supply cable     ACTION ORGANIZATION        BASIS    Cleaning and sanitizing of the Daily  container  Cleaning sanitizing of accessories in Operator  direct customer contact    Each session with  different customer  Visual inspection of the power supply  cable  in case of deterioration notify   the technical service    Visual inspection of the probe cable    in case of deterioration notify the  technical service     Oper
46. tests carried out in our company represent the specific requirements to  meet the needs of safety both of beauty and electro medical devices     In order to guarantee the safety of the client and the users  the latter must are  requested to have the technical assistance service to check periodically safety  standards and carry out maintenance service of the devices     According to actual directives in order to obtain good reliability and effectiveness  there must respect what follows     LI the installation  fine tuning  periodical inspections o reparations must be carried  out by the producer or by staff authorised by the producer     LI the electrical system must comply with security norms     LI The device must be used following the instructions indicated in the user manual   keep scrupulously the manual      L  The device must be used with the accessories supplied by the producer   Electrical safety    According to current directives           62 39 system safety  reliability and performance  can be guaranteed only if     E Installation  fine tuning and reparations are carried out by the producer or by  technicians  authorised by the producer     LI the electrical system must comply with security norms     LI The device must be used following the instructions indicated in the user manual     The publication C E l  n 12764 of November 1989 requests that the dispersion  currents and the resistance of the protection conductor be measured no further than  every two years  al
47. tive  for Unipolar  Atmospheric pressure  700   1060  hPa  25 mm    Room temperature   20    45    C  Resistive Electrodes diameter for Bipolar treatment 45 mm  70 mm      Conditions for stocking   transport Relative humidity  0   95  26 without  condensation  30 mm  40 mm Atmospheric pressure  500   1060  hPa  50 mm  Capacitive Electrodes diameter for Unipolar treatment Table container eternal dimensione  60 mm  Width x Height x Depth  Generator 34x23x20 5 cm  70 mm          Weight generator 6 35 Kg                            25      MATTIOLI   Es  riziriv      Ref  5801 2220 RF TOUCH       APPENDICES                                  POWER SUPPLY for RF TOUCH Appendix A   ENVIRONMENTAL CONSIDERATIONS             51 230 Vac  50 60 Hz   10  The aesthetic equipment for radio frequency unipolar and bipolar treatments RF  ower supply   Es  RFPS2 115 Vac  50 60 Hz   10     TOUCH  has been designed and manufactured to have minimal negative  environmental impact  in line with its operational and safety requirements       300 VA with unit GENERATOR Rigorous standards were followed in order to minimise the amount of waste  use of  Max mains power absorption                integrated toxic materials  noise  non required radiation and energy consumption   In accordance with careful research  the unit has been designed to optimise power  230 Vac 3 15 A T   5   20mm consumption in keeping with energy saving principles   Double delay mains fuses protection      115 Vac EG AUT w 5mm bw   Th
48. to   CALF  select the 4 available operating modes by pressing on the corresponding area on the   SHIN    screen   6  Select the ANATOMICAL ZONES button     If you want to use the Smart Card to create new customised programs or to run those    already stored  insert it in its slot  7  choose the wanted anatomical zone in the body present in the screen choosing    between those previously indicated     BODY AREA TREATMENT 8  run between the treatments indicated in the strip using the lateral scroll bar     By pressing the button BODY AREAS it is possible to select the treatment area to load 9  selectthe desired TREATMENT PROTOCOL   the therapy protocols available on the equipment  10  click on OPEN     The programs loaded in the inside memory of the device can be changed  but cannot    At this point is possible   be overwritten or cancelled     e To START the treatment  following the procedure START   It will be sufficient to choose an anatomical zone of the body shown in the screen to    have available the strip of the possible pathologies for the chosen zone and to load    To CHANGE the data of the treatment  proceeding like guide in MODIFY     the protocol of associated therapeutic suggestion  e To SAVE the parameters if necessary changed proceeding like guide in SAVE        14    Ref  5801 2220 RF TOUCH    TREATMENTS    Pressing the button TREATMENTS is possible to load the desired treatment protocol   1  select the TREATMENTS button    2  run between the treatments indicat
49. ts optimum performances it is  recommended to perform properly within the time and in the manner recommended  maintenance actions   For a correct replacement of the installed fuses  observe the following indications    1  open the fuse box using a screwdriver  making sure you insert the screwdriver in  the slot on the fuse box and levering up outwards  remove the fuse holder making it slide along the track  remove the installed fuses and replace them with new ones  replace the fuse holder into the fuse box  making it slide along the track   5  close the fuse box plastic door  It is recommended to perform periodic maintenance every year  in order to check    o the intensity of any leakage currents    o  thecontinuity and thus the integrity  of the ground conductor    o the correctness of the value of insulation resistance  in order to ensure the electrical safety of the device  ensure that it is operating in a safe  guaranteed  For this kind of intervention you should contact a qualified service technician  or alternatively MATTIOLI ENGINEERING S P A  or one of its authorized service centers     Bmw mM    WORKING PROBLEMS    Only technicians authorized by the manufacturer may access the interior of the unit   You should contact MATTIOLI ENGINEERING S P A  or its authorized service centers for any  repair work or further information     PRELIMINARY      MATTIOLI   ENG IS IRINC    The correct position while moving the machine  the apparatus has to be moved exclusively  by grippi
50. tute the fuses  to perform       operation in safety conditions       Donotopen the device  inside there are high voltages that may be hazardous      Only personnel authorized by the manufacturer may access the internal components  For  repairs and further information please contact MATTIOLI ENGINEERING S P A  or its  authorized service centers    WORKING PROBLEMS        Do NOT OPEN the unity  as HIGH VOLTAGE ELECTRICITY is present and may prove VERY  DANGEROUS     INTRODUCTION OF THE TECNOLOGY    Radiofrequency  what is it     Radiofrequency treatment is one of the new frontiers in aesthetic  They are  successfully applied as a non invasive method for skin rejuvenation and achieve  results that are very close to those obtained by surgical facelifts     This powerful technique is also widely applied in the treatment of cellulite  loose  tissues and localized adiposity     Radio Frequency treatments are based on emissions of high frequency radio waves  and exploit the high power thermal energy produced by the tissues when they are  exposed to radio waves        RF TOUCH is a equipment for radio frequency treatments to rejuvenate face and  body  and is one of the new aesthetic frontiers     RF TOUCH has been introduced as a non invasive skin rejuvenation technique  which  produces a result similar to surgical lifting     This powerful tool has a large application in the treatment of cellulite  relaxation of  the tissues and localized fat     The waves penetrate deeply into the 
51. ufacturer  it is essential that any handling of the equipment be in accordance  with the instructions provided     The limits of this manual are       the user manual cannot replace proper experience       the user manual  for particularly difficult operations  can only be a reminder of the  main operations     The manual is to be considered part of the equipment and must be preserved for  future reference until the decommissioning of equipment  The operating instructions  must be available for consultation in the vicinity of the machine and properly stored     This manual reflects the state of the art at the time of sale and cannot be considered  inadequate because later updated based on new information  The manufacturer has  the right to update products and manuals without necessarily updating preceding  products or manuals     The company will not assume any responsibility for any major cases     improper use of the machine      use against to specific national regulations      incorrect installation      defects in power      serious shortcomings in maintenance      changes and unauthorized interventions      use of parts or materials not specific to the model      total or partial non observance of the instructions      exceptional events     If you would like any further information  please check sales or get directly in touch  with the company MATTIOLI ENGINEERING S P A  to stay up to date on the best ways  to use these machines and to receive the necessary assistance 
52. xed and elastic   giving it a natural lifting effect     The heat produced into the skin tissue increases the local microcirculation  improving  the drainage of exceeding liquids  reducing the adipose tissue  resulting an effective  treatment for body remodeling and cellulite        RF TOUCH operates in two modes     Unipolar Capacitive  due to its depth of action and high power allows a  homogeneous warming of deep tissues of derma and adipose tissue     Is suited to treat the body that  tank to the deep stress  responds quickly to  treatments     It requires the cooperation of the client  those undergoing treatment must keep the  cylindrical mass in hand or must keep in contact the return plate with a part of the  body     Bipolar  produces a heating of tissues that is concentrated in the area under the two  poles of the electrode  and can spread the heat to the hypodermis     Acts on the surface level and is more used for the treatment on the face  neck and  d  collet       Does not require the cooperation of the client  does not use a cylindrical mass or a  return plate because the two poles are both on the electrode     HOW DOES IT WORK    RF TOUCH consists of a generator conveying an alternate current and an application  circuit composed of two electrodes     These electrodes are applied on the client s body that becomes a part of the electric  circuit     The electrodes can be      gt  unipolar  capacitive  type electrodes  the capacitive contact transfer is made    th
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
  Support de la Cryptolib CPS v5 - ASIP Santé  corega WLUSB-11mini2 取扱説明書  Sony XS-L103P5B Marketing Specifications  Holmes HASF1796RC User's Manual  100.0% T - Labindex  〔電気式〕『V-141BZ-TK』    Télécharger - Guillaume Ertauran  avertissement attention avertissement attention    Copyright © All rights reserved. 