Home
New Generation Data Sheets A1-2013
Contents
1. Those are equipped with IrDA Port and therefore are able to communicate with this external thermal printer Data saved into device can be selected from the menu and print it out as ECG format complete with case details 2GB SD Card code SAV CO907 This removable card holds approximately 100 hours of events ECG information and voice recording One card can hold data from multiple cases A flash data card reader enables data transfer from the card to a personal computer for use with the Saver View Express data management software Saver View Express code SAV C0019 Saver View Express is a comprehensive data management tool for the most demanding professional allowing to view and manage on your PC patient data downloaded from defibrillators With fully detailed data screen to record every aspect of the treatment including response times interventions and rescuer observations Fast Access Solutions AIVIA S Basic Mounted Cabinet code SAV CO836 Designed for an indoor use combining strenght and lightness with a polycarbonate cover and an ABS chassis Access to AED is protected by coated seals EM ea The front offers clear pictograms uu with the chain of survival and instruction for use tiigi Weight 1 5 kg Dimensions HxWxD 400x341x198 mm Wall Mount Bracket code SAV C0911 Composed of metal material Specifically designed for housing a SAVER ONE Defibrillator hold in it
2. card records up to 100 hours AED1LOG text file with detailed self test activity AEDFILES with complete recorded events Saver View Express data management software Data recording Event review PHYSICAL Size 26 5 x 21 5 x 7 5 cm Weight 1 95 kg with disposable battery 2 10 kg with rechargeable battery ENVIRONMENTAL Operating temperature 0 C to 55 C Storing Shipping temperature 35 C to 60 C without battery Humidity 0 to 95 relative humidity non condensing Sealing IP Protection IEC 60529 class IP54 slash proof dust protected Shock Drop Abuse Endurance IEC EN 60601 1 clause 21 1 meter drop impact force rough handling mobile tolerance Electrostatic Discharge EN 61000 4 2 Electromagnetic Compatibility EN 60601 1 2 Emission Immunity Electrical Protecion EN 60601 1 class type BF EC Directive Class IIb Temperature at 20 C MODEL NUMBERS Code SVO B0001 Semi Automatic Standard Version at 200J Code SVO B0002 Semi Automatic Power Version at 360J Code SVO B0847 Fully Automatic Standard Version at 200J Code SVO B0848 Fully Automatic Power Version at 360J CONFIGURATION OPTIONS Box Contents Conf Norm Standard Basic Configuration adult pads disposable battery carrying case Conf Rech Rechargeable Configuration adult pads accumulator charger station carrying case OY EARS WARRANTY C 0051 IMQ mark for 11 A1 2013 Safety amp Quality SS NS muet C
3. continuous operating Saver One T Basic code SVT B0008 Saver One T Advanced code svr BooosA Both SAVER ONE T Versions come equipped with one set of Adult and Pediatric reusable training pads a remote control an accumulator with its charger a quick reference card an user manual and a carrying case The Advanced version provides to instructors 4 extra scenarios which can be fully customized via personal computer once connected to AED Trainer with USB cable using a dedicated software CPR Manikin code MAN BO608 Half Body Training Manikin for Cardiopulmonary Resuscitation Practice with acoustic indicator for the correct deepness of compressions Composed of a jointed and removable head an openable torso enclosing il x a lung bag and its valve a knob on the back with three different selections WU p lllI A Adult Child or Neutral corresponding to three kinds of manikin resistance The articulated head allows inflating lungs only if the head is in the correct position to compressions ECG Monitoring amp Data Management 2 Lead ECCG Cable code SAN COO1 7 Suitable for SAVER ONE D and SAVER ONE P Defibrillators when used in ECG Monitoring mode The alternative to pads in case of long term monitoring to be connected to standard ECG electrodes Thermal Printer code S AN COO198 Works with SAVER ONE D and SAVER ONE P Defibrillators optioned with the Print Ready Configuration Conf Print
4. to rescuers running text and interactive graphics in tandem with voice messages ABOUT DEVICE a battery gauge with residual capacity the indicator of available memory for recording a notice if the microphone is active or OFF the local date and time ABOUT RESCUE the adult or child protocol in use the modality in use AED ECG or Manual the fibrillation and shock counts the elapsed rescue time the heart rate bpm the impedance ohms the energy level to be delivered joule a touch not touch pictogram the ECG waveform the R wave detection in Manual Synchronous a charging bar graph if device charges a CPR bar graph and cycles countdown S ADULT SYNC 3 1 13 30 30 2 MODE MERC ME Energy 150 i R R R R DO NOT TOUCH PATIENT Bx ANALYSING HEART RHYTHM 96 W ss on ooz nas s BATTERY OPTIONS Type Li SOCI2 Disposable code SAV C0903 Autonomy 250 complete rescue cycles shocks at 200J and CPR or 160 complete rescue cycles shocks at 360J and CPR or 24 hours ECG Monitoring for a new and fully charged battery Shelf Life 8 years when stored in its original packaging Standby Life 5 years once installed to AED assuming one battery insertion test and daily self tests but without switching AED on Type Li lon Accumulator rechargeable code SAV C0011 Recharging time 2 5 hours with the charger station code SAV C0014 Autonomy 200 shocks at 200J or 110 shocks at 360J or 14 hours in EC
5. with a new widely manageable software program which gives users the total control of device to suit their needs Practical and flexible with Advanced PBLS feature enabling healthcare providers to use the 15 2 CV ratio when performing a Pediatric Basic Life Support as required by Guidelines if more than one rescuer with a duty to respond Supreme graphical user interface and new tools to have total control of the defibrillator Biphasic escalating energy from 50 to 360J Slight yet solid with long lasting battery options to ensure the best outdoor and mobile use Functionality guaranteed by daily self test Wider connectivity with removable card USB and IrDA Port optional with Print Configuration Unique features combined with available configurations give rise to exclusive devices Saver One Maintenance Free Automatically performs daily monthly and six month extensive self checks of all main components battery internal electronics energy charge and disarm shock and ECG calibration systems Daily testing data are stored by the device as text file named AED1LOG easily readable by any computer AED runs further tests after each battery insertion and every time device is turned on A visual cue green red status indicator provides effective alert to users whether AED is in working order and ready for a rescue Service Mini Screen In standby the mini LCD screen displays a check mark
6. G Monitoring for a new fully charged battery Shelf Life 2 5 years or 300 charging cycles PADS OPTIONS Type Disposable pre gelled and self adhesive Adult Preconnected code SAV C0846 for patient gt 8 years or gt 25Kg 81 cm conductive surface Pediatric Code SAV C0016 for patient from 1 to 8 years old or lt 25Kg 31 cm conductive surface Cable lenght 120 cm Shelf Life 30 months EVENT RECORDING Internal memory 1Gbit 128 MB Memory capacity 6 hours of audio ECG and event Optional memory Removable SD card Length of storage depends on card capacity a 2GB card records up to 100 hours Data recording AED1LOG text file with detailed self test activity AEDFILES with complete recorded events Event review Saver View Express data management software PHYSICAL Size 26 5 x 21 5 x 7 5 cm Weight 2 30 kg with disposable battery 2 45 kg with rechargeable battery ENVIRONMENTAL Operating temperature 0 C to 55 C Storing Shipping temperature 35 C to 60 C without battery Humidity 0 to 95 relative humidity non condensing Sealing IP Protection IEC 60529 class IP54 slash proof dust protected Shock Drop Abuse Endurance IEC EN 60601 1 clause 21 1 meter drop impact force rough handling mobile tolerance Electrostatic Discharge EN 61000 4 2 Electromagnetic Compatibility EN 60601 1 2 Emission Immunity Electrical Protecion EN 60601 1 class type BF CF EC Directive Class Ilb Tempe
7. Protocols Adult Standard escalating 150 200 200J Adult Power escalating 200 250 360J Pediatric Standard or Power 50J fixed AED adult shock protocols can be customized Manual Protocol Selected by users from 50 to 360J For electric cardioversions in Synchronous mode the shock is synchronised to occur with the R wave of the ECG Energy Display Screen provides the energy to deliver both in Manual mode or in AED mode Charging time lt 9 seconds with a new and fully charged battery Depleted battery will result in a longer charging time Analysis time EN 60601 from 4 to 15 seconds Impedance 20 200 ohms Sensitivity EN 60602 2 4 AHADB MITDB source 97 Specificity EN 60602 2 4 AHADB MITDB source 99 Controls ON OFF Shock button 3 touch to surf the Menu 3 keys for select energy charge device or disarm Indicators Status LED indicator informing on device condition Battery gauge with remaining capacity rate Audible alerts and text display with service alarms Upgradeable Can be upgraded in the field through a USB cable or a removable card whenever protocols change ECG MONITORING Operation Through defibrillation pads or standard ECG electrodes attached to a separate 2 Lead patient monitoring reusable cable SAV C0017 ECG Size Automatic gain controlled by the display Heart Rate 30 300 bpm Sweep Speed 25 mm sec 9 4 TFT Color Display the most detailed and comprehensive screen provides valuable information
8. SAVER ONE SERIES the new generation SaVer One THE Series WES EE MADE ITALY M CE swyraay 0051 life S a breat A 34 amiitalia Keep it safe with us North Italy South Italy Office Office amp Production mm m Viale Gran Sasso 11 Via Cupa Reginella 15 Meme mu eae e amiutalia Tel 39 02 20509246 Tel 39 081 8060574 e A Fax 39 02 29520839 Fax 39 081 8764769 medical products www amiitalia com info amiitalia com i DEFIBRILLATOR Operation Semi Automatic Version ax e li ne Fully Automatic Version Energies Standard max 200J or Power max 360J Waveform Adaptive BTE biphasic truncated exponential everywhere for life conforming to patient chest s impedance Energy type Escalating from 50 to 360J Sudden Cardiac Arrest can happen anytime anywhere and without warning Protocols Various adult shock protocols available on request Factory default Adult Standard escalating 150 200 200J Adult Power escalating 200 250 360J Pediatric Standard or Power 50J fixed lt 9 seconds with a new and fully charged battery Depleted battery will result in a longer charging time EN 60601 from 4 to 15 seconds The person affected has only few precious minutes left for a chance of survival YOUR FIRST AID COULD BE SOMEBODY S LAST CHANCE SAVER ONE AEDs are designed for a public access use and licensed to administer fast and safe rescues Highly effective and user friendly for an
9. asting battery options to ensure the best portability in any circumstance Biphasic technology up to 360J energy Unique features combined with available configurations give rise to exclusive devices Meet AHA ERC 2010 Guidelines Saver One Maintenance Free Automatically performs daily monthly and six month extensive self checks of all main components battery internal electronics energy charge and disarm shock and ECG calibration systems Daily testing data are stored by the device as text file named AED1LOG easily readable by any computer AED runs further tests after each battery insertion as well as every time the device is turned on A visual cue green red status indicator provides effective alert to users whether AED is in working order and ready for a rescue SEMI AUTOMATIC two buttons Helpful Text Screen The mini LCD screen always displays a battery gauge with its residual percentage charge and runs text in tandem with audible voice instructions helpful in noisy and chaotic environments Synergic INFO Button The z button provides valuable device or battery technical information to users and is serviceable for changing the language FULLY AUTOMATIC CPR Coaching More instructive voice and text prompts guide user through rescue A built in metronome assist one button responder during the CPR providing audio cues for the appropriate number and rate of chest compressions E t A Child Capabilit
10. at 360J or 14 hours in ECG Monitoring for a new fully charged battery Shelf Life 2 5 years or 300 charging cycles PADS OPTIONS Type Disposable pre gelled and self adhesive Adult Preconnected code SAV C0846 for patient gt 8 years or gt 25Kg 81 cm conductive surface Pediatric Code SAV C0016 for patient from 1 to 8 years old or lt 25Kg 31 cm conductive surface Cable lenght 120 cm Shelf Life 30 months EVENT RECORDING Internal memory 1Gbit 128 MB Memory capacity 6 hours of audio ECG and event Optional memory Removable SD card Length of storage depends on card capacity a 2GB card records up to 100 hours AED1LOG text file with detailed self test activity AEDFILES with complete recorded events Saver View Express data management software Data recording Event review PHYSICAL Size 26 5 x 21 5 x 7 5 cm Weight 2 30 kg with disposable battery 2 45 kg with rechargeable battery ENVIRONMENTAL Operating temperature 0 Cto 55C Storing Shipping temperature 35 C to 60 C without battery Humidity 0 to 95 relative humidity non condensing Sealing IP Protection IEC 60529 class IP54 slash proof dust protected Shock Drop Abuse Endurance IEC EN 60601 1 clause 21 1 meter drop impact force rough handling mobile tolerance Electrostatic Discharge EN 61000 4 2 Electromagnetic Compatibility EN 60601 1 2 Emission Immunity Electrical Protecion EN 60601 1 class type BF CF EC Dir
11. confirming AED is ready for use and a battery gauge informing about the residual charge Will run error codes in faulty conditions Entirely Discretionary 6 push buttons allowing users to get the total control of defibrillator while in use select the best modality Manual Synchronous or Asynchronous or simply AED to treat SCA according to events take decision for shock anytime by choosing the right energy level to be delivered at each shock and get the device charged and ready to shock whenever needed or even disarm it in case defibrillation is not more required After shocks the heart rhythm rate can be watched over using the same defibrillation pads or in case of longer monitoring by connecting standard ECG electrodes to a separate optional reusable cable ach step is conducted with the appropriate running features selected and set up in the device software by users mt ase Lhild Capability Can be used on patients of any age with Adult or Pediatric proper electrodes Device Sn Pediatric pads are installed and automatically adjusts to use a more appropriate lower energy level 50J DEFIBRILLATOR Operation AED Semi Automatic default ECG Monitoring Manual Asynchronous or Synchronous used to convert atrial or ventricular tachyarrhythmias Energies Standard max 200J or Power max 360J Waveform Adaptive BTE biphasic truncated exponential conforming to patient chest s impedance Energy type Escalating from 50 to 360J AED
12. ective Class IIb Temperature at 20 C MODEL NUMBERS Code SVD B0004 Code SVD B0005 Standard Version with maximum energy at 200J Power Version with maximum energy at 360J CONFIGURATION OPTIONS Box Contents Conf Norm Standard Basic Configuration adult pads disposable battery carrying case Conf Rech Rechargeable Configuration adult pads accumulator charger station carrying case Conf Print Print Ready Configuration adult pads disposable battery carrying case IrDA port and thermal printer Conf Rech Print Rechargeable amp Print Ready Configuration adult pads accumulator charger station carrying case IrDA port and thermal printer OYEARS WARRANTY IMQ mark for Safety amp Quality 005 1 1D A1 2013 Sater One P the handy PRO AED SAVER ONE P is a tough small and lightweight Defibrillator easy to carry and use anywhere and able to act as an AED or a Manual Defibrillator or a Basic Cardiac Monitoring device HIGHLY FLEXIBLE AND VERSATILE WITH ADVANCED CAPABILITIES AED per default reliable for any BLS rescuer can be easily switched in a Manual Defibrillator giving to ALS responders the best decision making control for a manual shock timing or an electric cardioversion synchronised shock To meet ALS professionals SAVER ONE P has been designed with all advanced key features to make fast and effective defibrillation everywhere and in any circumstance even the hardest and has been equipped
13. hild Capability Can be used on patients of any age with Adult or Pediatric proper electrodes Device DEFIBRILLATOR Operation AED Semi Automatic a e i ne ECG Monitoring capability Energies Standard max 200J or Power max 360J Waveform Adaptive BTE biphasic truncated exponential the AED goes beyond conforming to patient chest s impedance Energy type Escalating from 50 to 360J Protocols Various adult shock protocols available on request SAVER ONE D 1s a rugged small and lightweight AED with ECG Monitoring capability Totally reliable for trained users featuring advanced capacities to help improve lifesaving outcomes THE RIGHT CHOICE FOR HARSH OUTDOOR OR MOBILE USE Adult Standard escalating 150 200 200J Adult Power escalating 200 250 360J Pediatric Standard or Power 50J fixed lt 9 seconds with a new and fully charged battery Depleted battery will result in a longer charging time EN 60601 from 4 to 15 seconds Factory default Charging time While in AED mode it allows the user to view the ECG and everything needed to know about Analysis time Impedance 20 200 ohms the patient and ongoing rescue treatment on a very large 12x8 cm full color interactive display Sene EN 60602 2 4 AHADB MITDB source 97 Additionally the SAVER ONE D can be switched in a ECG Monitoring mode to allow for watch over the Specificity EN 60602 2 4 AHADB MITDB source 9996 rhythm and heart rate while using defibrilla
14. messages Unique features combined with available configurations give rise to exclusive devices Meet AHA ERC 2010 Guidelines ADULT AED 30 2 be MODE 3 3 i VA 3 1 13 30 Ye 80 bom 120 Bip Energy 150J eee Saver One D Maintenance Free Automatically performs daily monthly and six month extensive self checks of all main components battery internal electronics energy charge and disarm shock and ECG calibration systems Daily testing data are stored by the device as text file named AED1LOG easily readable by any computer AED runs further tests after each battery insertion as well as every time the device is turned on A visual cue green red status indicator provides effective alert to users whether AED is in working order and ready for a rescue AED ECG Monitoring DO NOT TOUCH PATIENT ANALYSING HEART RHYTHM TT p 26 D pee 0102 2013 11 15 ABOUT DEVICE a battery gauge with residual capacity the indicator of available memory for recording a notice if the microphone is active or OFF the local date and time ABOUT RESCUE the adult or child protocol in use the modality in use AED or ECG the fibrillation and shock counts the elapsed rescue time the heart rate bpm the impedance ohms the ECG waveform a touch not touch pictogram a charging bar graph if device charges the energy level to be delivered joule a CPR bar graph as countdown a CPR cycles count Service Mini Sc
15. rature at 20 C MODEL NUMBERS Code SVP B0006 Standard Version with maximum energy at 200J Code SVP B0007 Power Version with maximum energy at 360J CONFIGURATION OPTIONS Box Contents Conf Norm Standard Basic Configuration adult pads disposable battery carrying case Conf Rech Rechargeable Configuration adult pads accumulator charger station carrying case Conf Print Print Ready Configuration adult pads disposable battery carrying case IrDA port and thermal printer Conf Rech Print Rechargeable amp Print Ready Configuration adult pads accumulator charger station carrying case IrDA port and thermal printer OYEAn WARRANTY C IMQ mark for 1 1P A1 2013 Safety amp Quality 0 0 D SAVER ONE AED Seres supplies and accessories z Sater One T A smart and easy to use AED Trainer providing realistic training for many responders simultaneously Designed to meet needs of any instructor it helps your responders learn to use defibrillators in simulated sudden cardiac arrest episodes for an extremely realistic training experience A non shocking unit that follows the 1 2 3 step operations of the Saver One defibrillator and guides responders with voice prompts in various languages from ECG analysis until shock and CPR It is pre configured with 10 realistic training scenarios manageable from distance with a wireless remote control and is equipped with a rechargeable battery which allows a 20 hours of
16. reatment Able to simulate several ECG rhythms VF VT NSR Asystole etc and display the energy level discharged up to 360J Connecting Cable code SAN CO158 Spare connecting cable for Smart Simulator S1 S r One
17. reen In standby the mini LCD screen displays a check mark confirming AED is ready for use and a battery gauge informing about the residual charge Will run error codes in faulty conditions Helpful Menu 3 buttons for navigating the software menu to set up device at user leisure adjust the local date or time adapt the screen or volume to ambient lights and noises exclude the microphone while recording events select a different language print out the ECG files or simply get information on device and battery CPR Coaching More instructive voice and text prompts guide user through rescue A built in metronome assist responder during the CPR providing audio cues for the appropriate number and rate of chest compressions sepsesWwhen Pediatric pads are installed and automatically adjusts to use a more appropriate lower energy level 50J BATTERY OPTIONS Type Li SOCI2 Disposable code SAV C0903 Autonomy 250 complete rescue cycles shocks at 200J and CPR or 160 complete rescue cycles shocks at 360J and CPR or 24 hours ECG Monitoring for a new and fully charged battery Shelf Life 8 years when stored in its original packaging Standby Life 5 years once installed to AED assuming one battery insertion test and daily self tests but without switching AED on Type Li lon Accumulator rechargeable code SAV C0011 Recharging time 2 5 hours with the charger station code SAV C0014 Autonomy 200 shocks at 200J or 110 shocks
18. s original carrying case Weight 1 37 kg Dimensions HxWxD 230x255x155 mm Carrying Case code SAV C0916 Semi Rigid for a reliable protection and transport of Saver One Defibrillators Accessories and spare batteries can be stored in its inside compartments Made of special shockproof and splashproof material Zipper opening and D ring to hook from the back AIVIA 100 Alarmed Mounted Cabinet code SAV C0028 Ergonomic with no sharped corners Made of ABS and polycarbonate Access protected by plastic seals Internal grip strap to hold AED Sensor for automatic day night light when dark the compartment lits up if opened Opening the hood automatically triggers a visual alarm flashing red LED and an audio signal hooter type two tones 95 dB Weight 3 5 kg Dimensions HxWxD 580x380x220 mm Adwvanced Cabinets AIVIA Family offers several combinations for the protection of AEDs even outside and or for a complete surveillance The AIVIA 200 Series gives an outdoor protection from dust humidity rain cold etc The AIVIA 300 Series is able to protect and monitor AEDs giving a complete overview of their operating status Simulator Tester Smart Simulator S1 code SSS BOO09 This equipment can be used for a complete operating test of Saver One Defibrillators It comes with a dedicated cable to be plugged to any Saver One AED in order to let it run as it was a real lifesaving t
19. tion pads or standard ECG electrodes connected to a separate cable Controls ON OFF Shock button 3 touch to surf the Menu Indicators Status LED indicator informing on device condition Battery gauge with remaining capacity rate Practical and flexible with Advanced PBLS feature enabling healthcare providers to use the 15 2 CV ratio when Audible alerts and texi displav with service alain performing a Pediatric Basic Life Support as required by Guidelines if more than one rescuer with a duty to respond Upgradeable Can be upgraded in the field through a USB cable or a removable card whenever protocols change ECG MONITORING Operation Through defibrillation pads or standard ECG electrodes attached to a separate 2 Lead patient Great graphical interface in tandem with Mill dea sue ce Oba rapin ECG Size Automatic gain controlled by the display instructive voice prompts to guide rescuers Heart Rate 30 300 bpm Sweep Speed 25 mm sec Functionality ensured by automatic daily self test Slight yet solid with long lasting battery options to ensure the best portability in any circumstance More alternatives for recording and transfer data internal memory removable card USB and IrDA Port optional with Print Configuration Biphasic technology up to 360J energy 9 4 TFT Color Display the most detailed and comprehensive screen provides valuable information to rescuers running text and interactive graphics in tandem with voice
20. y Can be used on patients of any age with flashing icons on the keyboard providing information on the pads in use Device senses when Pediatric pads are installed and adjusts to use a more appropriate lower energy level 50J BATTERY OPTIONS Type Li SOCI2 Disposable code SAV C0903 Autonomy 300 complete rescue cycles shocks at 200J and CPR or 200 complete rescue cycles shocks at 360J and CPR or 35 hours ECG Monitoring for a new and fully charged battery Shelf Life 8 years when stored in its original packaging Standby Life 5 years once installed to AED assuming one battery insertion test and daily self tests but without switching AED on Type Li lon Accumulator rechargeable code SAV C0011 Recharging time 2 5 hours with the charger station code SAV C0014 Autonomy 250 shocks at 200J or 150 shocks at 360J or 21 hours in ECG Monitoring for a new fully charged battery Shelf Life 2 5 years or 300 charging cycles PADS OPTIONS Type Disposable pre gelled and self adhesive Adult Preconnected code SAV C0846 for patient gt 8 years or gt 25Kg 81 cm conductive surface Pediatric Code SAV C0016 for patient from 1 to 8 years old or lt 25Kg 31 cm conductive surface Cable lenght 120 cm Shelf Life 30 months EVENT RECORDING Internal memory 1Gbit 128 MB Memory capacity 6 hours of audio ECG and event Optional memory Removable SD card Length of storage depends on card capacity a 2GB
21. y lay rescuer even without minimal training Charging time Analysis time Impedance 20 200 ohms SAVER ONE Semi and Fully Automatic defibrillators are two dependable members of our AED family en 2 AT a ee E a The Fully Automatic administers a defibrillating shock when appropriate with no shock button PEE a buttons for Semi Automatic ONIGEE Switch Shack for the user to press while the Semi Automatic administers a shock at the press of a button 1 button for Fully Automatic ON OFF switch pads warning on pads not not well connected adult child informing on pads type in use don t touch patient warning to stay clear touch patient informing it s safe to touch Flashing Icons Choose the best portable AED that s right for you to save lives everywhere in any public circumstance home office school hotel airport train beach gym pool disco etc and before EMS team arrives Indicators Status LED indicator informing on device condition Battery gauge with remaining capacity rate Audible alerts and text display with service alarms Upgradeable Can be upgraded in the field through a USB cable or a removable card whenever protocols change Automated testing to vouch daily functionality A new look complete with all pictograms which light up necessary to guide rescuers step by step More alternatives for recording and transfer data internal memory removable card USB Slight yet solid with long l
Download Pdf Manuals
Related Search
Related Contents
WHAT IS CPAP (Continuous Positive Airway Instruction Manual 69TM Long Ceramic Manhattan ExpressCard/34 E le c tro c a rd io g ra - S E -3 0 0 à 3 p is te s User ManUal - FOTO KARMI DPI-1200 User Manual the Zooka zs740 manual 取扱説明書ダウンロード g1808x, g1838x, g1848x deep fat fryers Copyright © All rights reserved.