Home

USER MANUAL

image

Contents

1. 16 3 1 Installing the Battery 16 3 2 Instrument connection 17 3 2 1 IP camera connection 17 3 2 2 Analog camera test 18 3 2 3 HD Coaxial camera connection 18 3 3 OSD menu 19 3 3 1 Video monitor test PTZ control 22 3 3 2 Color bar generator TV OUT 31 3 3 3 ONVIF 32 3 3 4 IP camera test 41 3 3 5 SDI Camera Test optional 43 3 3 6 CVI camera test optional 45 3 3 7 TVI camera test optional 49 3 3 8 AHD camera test optional
2. 50 3 3 9 IP address scan 52 3 3 10 PING Test 53 3 3 11 Cable test 53 3 3 12 Cable tracer optional 54 3 3 13 Port finder 55 3 3 14 Data monitor 57 3 3 15 Optical power meter Optional 57 3 3 16 Visual Fault Locator optional 59 3 3 17 Digital Multi meter optional 60 3 3 18 Media Player 66 3 3 19 Audio player 67 3 3 20 LED Flashlight 68 3 3 22 TDR cable test optional 69 3 3 23 Calculator
3. 96 1 Safety information The tester is intended to use in compliance with the local rules of the electrical usage and avoid to apply at the places which are inapplicable for the use of electrics such as hospital gas station etc To prevent the functional decline or failure the product should not be sprinkled or damped The exposed part of the tester should not be touched by the dust and liquid During transportation and use it is highly recommended to avoid the violent collision and vibration of the tester lest damaging components and causing failure Don t leave the tester alone while charging and recharging If the battery is found severely hot the tester should be powered off from the electric source at once The tester should not be charged over 8 hours Don t use the tester where the humidity is high Once the tester is damp power off immediately and move away other connected cables The tester should not be used in the environment with the flammable gas Do not disassemble the instrument since no component inside can be repaired by the user If the disassembly is necessary indeed please contact with the technician of our company The instrument should not be used under the environment with strong electromagnetic interference Don t touch the tester with wet hands or waterish things Don t use the detergent to clean and the dry cloth is suggested to use If the dirt is not
4. 68 UL Connect a network cable from a PoE switch to the IP tester s PSE IN port Connect an IP camera or other PoE using node to IP tester s LAN port the PoE voltage and the cable s pin connection status show on the screen Note This test if for measuring the voltage being drawn by the PoE node and the IP tester must be between the PoE switch and the PoE node for this test to work Note The PoE switch must be connected to the PSE IN port The powered device such as IP camera or A PoE node must be connected to the LAN port A Note Do not connect PoE power supply equipment such as a PoE switch to the tester s UTP SCAN port otherwise it will damage the tester 3 3 22 TDR cable test optional A Note The testing cable can t be connected to any equipment or it will damage the tester Connect Alligator clip cable to the TDR port and the cable must connect well before testing or it will influence the accuracy Click to enter and click Start to test 15 46 12 X Length Om SYV 75 2 SYV 15 2 iu Start Built in BNC cable network cable RVV control cable Telephone line and TVVB cable etc can test 11 groups user defined cable can be set 69 Tl 15 46 24 X Length Om Cable Number Type Wave velocity L SYV 75 5 207 Type 2 SYV 75 3 207 3 SYV 75 2 200 4 RVVP 160 5 RVV 178 Wave User defined calibration Choose the cable 100 meters to 200
5. 72 3 3 24 Browser 73 3 3 25 IP camera viewer 73 3 3 26 DC12Vpower output 75 3 3 27 Application tools 76 3 3 28 APPS Tools 85 3 3 29 System Set 86 3 3 30 Update 89 3 4 DC12V 1A power output 89 3 5 Audio test 90 4 Specifications 91 4 1 General Specifications 91 4 2 Multi meter specifications 93 4 3 Optical power meter specifications 96 4 4 Visual fault locator specifications
6. 4 Save setting Click icon save setting on the right toolbar to enter Snapshot and record can choose auto or manually save If choose Auto save files will be auto named if manually save you can manually enter the name of a video or photograph 1920x1080P 30fps wR 0 07 43 _ ty Pholo Storage Auto Widen Storage Auto o D od Cancel 3 3 7 TVI camera test optional HD TVI camera TVI dome camera test and PTZ control Click icon to enter S49 TL Ger p056 x No video signal input When tester received HD TVI camera image the above bar display the image resolution Double click the screen full screen image display Tester support resolution as follows 1280x720P 25FPS 1280x720P30FPS 1280x720P 50FPS 1280x720P 60FPS 1920x1080P 25FPS 1920x1080P 30FPS 1920x1080P 50FPS 1920x1080P 60FPS 1920x1080P 30fps T E 10 06 25 X More details such as PTZ control Coaxial camera menu setting snapshot record save and playback etc Plsreferto 3 3 6 CVI camera test 3 3 8 AHD camera test optional HD AHD camera CVI dome camera test and PTZ control Click icon to enter 50M Ge 98 09 56 X No video signal input 5 Sea ot When tester received HD AHD camera image the above bar display the image resolution Double click the screen full screen image display Tester s support resolution as follows 1280x720P 25FPS 1280x720P 30FPS 1920x1080P 25FPS 1920x1
7. 8101 16 01 23 X to open the Link Monitor app This app is used to see if an IP address is occupied Link monitor Click the icon by other network devices This will avoid new address conflicts Click Add and enter the desired IP address To test different network segments click the Settings icon on the main menu and go to IP Settings and make the desired changes Once the desired IP addresses are added to the Link Monitor list click Start If the IP address status shows a check mark the IP address is occupied If the IP address status shows an X the IP address is available Click Stop to stop the testing 16 01 47 X srt foe fy 4 192 168 0 3 z Se APR es Application Add an IP camera or other network device to the current network group the new IP address must not be 232 occupied otherwise it will cause IP conflicts and stop the equipment normal working Link monitor can check if the new setting IP address is occupied RTSP Player The RTSP Player app will allow you to view the RTSP video stream from an IP camera If you were unable to view your camera via the ONVIF or IPC Test apps it is possible your camera will have an RTSP stream and you can view live video From the main menu select the APP Tool folder and then select the RTSP Player to open the app If the IP camera uses MJPEG select the RTSP icon If the IP camera uses H 264 select the RTSP HD icon 10
8. jack and the red test lead to the V Q jack b to select Q enter the Q measurement the tester default Auto range status Press the key manually select range Press NEAR to restore Auto range Manual range Connect the red lead to black leads will display the measure range 000 00 gt 6600 range 0 000 KQ 6 600KQ range 00 00 KQ 66 00KQ range 0 000 MQ gt gt 000 0KQ gt 660 0KQ range gt 6 600MQ range 5 00 00 MQ 66 00MQ rang Continuity Testing 63 UL a Connect the black test lead to the COM jack and the red test lead to the V Q jack b to select enter the continuity test Connect test leads across two point of the circuit under testing c If continuity exists 1 e resistance less than about 50Q built in buzzer will sound Diode Testing a Connect the black test lead to the COM jack and the red test lead to the V Q jack the red lead anode b to select enter the diode testing c Connect test red lead across to the anode the black lead to the cathode of the diode under testing d Connect test red lead across to the cathode the black lead to the anode of the diode under testing e Tested diode forward voltage low 30mv there is sound indication then can finish the testing quickly without view the screen Capacitance Measuring a Connect the black test lead to the COM jack and the red test lead to the V Q jack b
9. 00 00 dBm 1300 1490 1550 1625 Data hold and Relative measuring use together the data is yellow while the function is effect S58 Ul 16 50 00 gt 850 1300 1310 1490 1550 1625 Hold Data Difference mW dBm 3 3 16 Visual Fault Locator optional Click icon a to enter 16 51 49 gt Visible laser light source damage to the eyes to avoid eye contact Steady mode Evasive 1Hz Evasive 2Hz Time off VFL four status can select Steady mode Evasive 1Hz Evasive 2Hz and Time off Click button Steady mode to enter steady status click button Evasive 1Hz and Evasive 2Hz to enter pulse mode click button Time off VFL be turned off Timed turn off can select 5mins 10mins 30mins 60mins and 120mins 5900 5 16 52 06 gt Visible laser light source damage to the eyes to avoid eye contact A 650nm Steady mode Evasive 1Hz Evasive 2Hz Time off Click Steady mode red laser sources emit steady click again to quit F 16 52 28 X Visible laser light source damage to the eyes to avoid eye contact A 650nm Steady mode Evasive 1Hz Evasive 2Hz Time off Click icons Evasive 1Hz or Evasive 2Hz to enter pulse mode the red laser sources emitted by a certain frequency press it again to quit 3 3 17 Digital Multi meter optional 1 Click icon to enter 2 SYMBOLS 6000 U DC Voltage Measuring A DC Current Me
10. 0 1 7 45 ms 951 664ms 421 709 ms 3 3 28 APPS Tools Click the icon to open the Tool Folder You can move desktop icons into the Tools Folder by APPS pressing on the icon for a few seconds until the screen below appears Multifunction Tester ia 9 2014 12 30 11 45 37 Oo Audio Player FLASHLI Update APP TOOL You can also move an icon back to the desktop by pressing on the icon for a few seconds until it asks you if you want to move the icon back to the Desktop 85 00 Multifunction Tester N a 2014 12 30 11 46 08 me ee fe WA Ok Cancel Audio 3 3 29 System Set Click icon to enter E 17 07 01 2 Language Simplified Chinese Traditional Chinese English and others Date Time Set the Date time IP setting Set the IP address Subnet Mask Default Gateway DNS address Test multiple network segments IP click Advance to display IP setting interface then click Add to add new IP address as tester s address to test 86 0 Settings T FP 14 44 01 X Settings IP Settings 197 168 0232 255 255 255 0 192 168 0 1 114 114 114 114 After setting IP address refer to above photos the tester can test two network segments IP camera 192 168 0 0 and 192 168 1 0 WLAN Turn WiFi off or on by pressing the Open the wifi button Once WiF1 is turned on it will scan for wireless networks in your area Select the desired wireless network SSID and enter your password to connectnetwor
11. 1A OUTPUT port of the IP camera tester to avoid destroy man made damage is not within the Company s warranty b Don t output this DC12V 1A power to DC12V IN port to avoid destroy otherwise the tester will damage and man made damage is not within the Company s warranty c The IPC tester power output is close to 1A if the IP camera s power is over 1A the tester will auto enter protection mode Disconnect all the connections of the tester and then connect the tester with power adaptor to resume the tester d Make sure the tester has a sufficient charge otherwise the tester will not able to provide enough output powe e 3 5 Audio test You can test the audio input from audio pickup devices by connecting the audio pickup device to the IP tester with the supplied audio cable Support audio record and storage S90 TL 4 Specifications 4 1 General Specifications IPC 3500 models optional Display 3 5 inch Capacitive touch screen resolution 4800 RGB x 320 Network port 10 100M auto adapt RJ45 SDI camera test 1 channel SDI IN BNC Input Support resolution 720p 60fps 1080p Optional 30fps 1080i 60fps CVI video Signal 1 channel CVI in BNC connector resolution max 720p 25 Test Optional 30 50 60fps 1080p 25 30fps TVI video Signal 1 channel TVI in BNC connector resolution max 720p 25 Test Optional 30 50 60fps 1080p 25 30fps AHD video Signal 1 channel AHD in BNC connector resoluti
12. 3 1 in the manual Click x or press to quit and return the main menu 3 3 6 CVI camera test optional HD CVI camera CVI dome camera test and PTZ control Click icon hej to enter Ge pg056 x No video signal input Playback Piz se When tester received HD CVI camera image the above bar display the image resolution Double click the screen full screen image display Tester s support resolution as follows 1280x720P 25FPS 1280x720P 30FPS 1280x720P SOFPS 1280x720P 60FPS 1920x 1080P 25FPS 1920x1080P 30FPS 1920x1080P 30fps q f 10 06 25 X G A Snapaot S45 Wl 1 PTZ control 1 1 Coaxial PTZ control Click the icon PTZ on the right toolbar Port Select Coaxial control 19202 1080F 30ips 10 06 48 X Port Coacitron Address Honza verica Set Position Click the screen to PTZ address parameters setting Port Coacitroan Address Horizontal Speed Vertical Speed Set Position Call Position i OR Cancel Operation details Pls refer to 3 3 1 PTZ 1 PTZ control parameters setting A PTZ address and the connected camera s or decoder address must be same Then IP tester can test and control it After setting Parameters PTZ control and zoom in out image SAG TL 1970x1080P 30fps Playback re r Das PTZ control by Finger touch Click the image to slip left right upward downward or zoom in or zoom o
13. IN port If the testing is ok the tester displays several gradually dwindling photos on the desktop 3 3 2 Color bar generator TV OUT Click to enter the tester send the color bars from the Video out port Click the icon PAL select PAL NTSC output formats eo 16 37 27 X Click the selected color bars testing image or single bar red green blue white or black Double click to full display on the screen and output click Ea to return main menu 310 Application A When maintaining the dome camera the tester sends out the color bar by its BNC output to the monitor at the monitoring center If the monitor receive the color bar it means the video transmit channel works normally Meanwhile on the basis of the received color bar the monitoring center can judge if transmission has loss or interference B The tester sends out the pure color bar such as white and black color to test the monitor whether has bright or black dots C The tester sends out video signal image to test if the image received by the monitor has excursion 3 3 3 ONVIF The Open Network Video Interface Forum ONVIF app is used to connect to ONVIF compliant IP cameras only If the IP camera s video stream is MPEG4 use the ONVIF SD mode If your IP camera s video stream is H 264 use ONVIF HD High Definition HD mode cannot support MPEG4 While in SD mode if the network camera resolution is 720P or higher 720P the imag
14. Management Software of the corresponding IP camera then can view the image after setting that Video Management Software Video Management Software displays IP camera s image by software decompression hereby the image 7301 may be not clear or fluent Note The Video Management apps are third party applications Our company does not support these apps nor make any usage claims We do not assume any legal liability F ya IPC viewer Click desktop icon several seconds to uninstall this application W SENT Do you want to uninstall this app Cancel Click icon update in the IPC viewer interface to update Video Management Software B74 Ul 15 45 06 gt Installation 3 3 26 DC12Vpower output Click icon to enter and turn on DC 12V power output interface 7 16 59 33 2 DC power output OFF When the tester is turned on the 12VDC power output function sis automatically turned on If the IP tester is turned off the 5VDC USB can still be used to power an external USB device 75 Hl 17 02 07 2 DC power output ON A Don t input any power into the DC12 1A OUTPUT port of the Pcamera tester to avoid destroy 2 Don t output this DC12V 1A power to the DC12V IN port of the IP camera tester to avoid destroy 3 The IPC tester power output is close to 1A if the IP camera s power is over 2V the tester will auto enter protection mode Disconnect all the connections of
15. Select P to enter enter the capacitance measurement c The tester default auto range status and manual range by press upward and downward key Auto rang by press the key NEAR Manual range 0 000nF gt 6 600nF range 00 00nF gt 66 00nF range 000 0nF gt 660 0nF range 0 000uF gt 6 600uF range 00 00uF gt 66 00uF range 000 0uF gt 660 0uF range 64 TL 0 000mF gt 6 600mF range 00 00mF gt 66 00mF range d Before connect test leads across two sides of the capacitor under measurement be sure that the capacitor has been discharged fully A Note a The capacitance of a capacitor should be tested separately should not test in the installation of circuit b To avoid electric shock be sure the capacitors have been discharged fully before measuring the ca pacitance of a capacitor c While testing the capacitance of a capacitor to 660uF the Max time will be 6 6 seconds if the capacitor is leaked or damaged the data can t be read The tester will be normal after disconnecting the capacitor Manual range and Auto range When testing click Range select to change the value click Auto range to enter Auto measurement 16 53 17 amp 000 V ar A Range Hold data Difference Auto Range Data hold Click Hold data to enter the data be hold the value is green Press it again to quit Relative value measurement 65W Click Relative to enter the tester Auto save
16. port display the PTZ control code of the multifunctional keyboard or the DVR Controller can check the status of the RS485 transmission through the code on the display The RS485 communication rate must be the same Application Check the RS485 communication states of the video optical transmitter whether normal Engineer can analyze the protocol and check the data through the displayed code 3 3 15 Optical power meter Optional Click icon to enter with five wavelength 1625nm 1550nm 1490nm 1310nm 1300nm 850nm linear or nonlinear optical power display both for optical power testing and Fiber link loss relative measurement It is necessary tools for installation and maintenance optical fiber communication cable television and CCTV security system A Please keep the fiber connector and the dust cap be clean and clean the detector with the special alcohol Data hold While testing click Hold to data hold the data will not change It s convenient to read Press 57W again to quit a F 16 49 39 X 1300 1490 1550 1625 Relative power value optical link loss measurement While testing set the wavelength for measurement Click relative difference to test the tester Auto save current fiber power value as the base reference value Input another optical fiber to be measured the displayed new measurement and relative value is red color Press it again to quit a 16 49 49 X
17. quit from image display and return to IP camera test interface A Under the IPC Test on the IP camera image display there is Video Menu icon click Video Menu appears toolbar Snapshot Record Photo Playback PTZ Set etc Please refer to ONVIF to use these functions 3 3 5 SDI Camera Test optional to enter SDI camera test Dome camera test and PTZ control click icon 17 13 04 E Photo No video signal input 43 When tester received SDI camera image it will display the image data by two fingers quickly double click the screen the image display on the full screen The tester support resolution as follows 1280x720P 25Hz 1280x720P 30Hz 1280x720P 50Hz 1280x720P 60Hz 1920x1080P 25Hz 1920x1080P 30Hz 1920x1080I 50Hz 1920x1080I 60Hz eJsn DRE 1280x720p 25Hz HD J T 5 17 13 04 X When SDI tester detects the camera input image resolution is 1080p 60Hz or1080p 50Hz the tester s screen will display Does not support playing 1920 1080p 60Hz If no SDI camera image input the tester s screen display NO video signal input e 8 02 05 x AN374238 1920X1080p 50Hz 30G SAAT Select relative function on the right side Toolbar to operate Snapshot Recording Photos Video playback PTZ control Brightness and Storage set its operating as the same as the video monitor function Please refer to the relevant instructions 3
18. record and playback Coaxial PTZ control and call camera OSD menu 2 3 5 Analog camera test Displays an analog camera image on the 4 3 inch480 320LCD screen display Supports PAL amp NTSC formats The LCD screen s back light brightness video image brightness contrast and color saturation are all adjustable 2 3 6 Video level meter optional Perform NTSC and PAL NTSC and PAL video amplitude signal measurements for PEAK to PEAK and SYNC levels Video signal PEAK to PEAK level For NTSC format the video signal level is 140 15IRE For PAL format the video signal level is 1000 200mV If the level is too low it will cause the image to lose quality and limit the distance it will travel over cable If the level is too high it will lead to wash out of the image COLOR BURST chroma level COLOR BURST level Testing the color burst level will determine if the burst signal is sufficient to trigger the displays color producing circuit Burst will diminish in amplitude over longer cable runs and can get fall below the threshold for the video display to show a color image For NTSC format the Chroma standard level is 40 IRE For PAL format the Chroma standard level is 280Mv SYNC level Testing the amplitude of the video sync pulse to verify if the video level is correct For NTSC format the SYNC level is 40 5IRE B a y For PAL format the SYNC level is 300 35mV If the level is too low it will cause the image to not frame out properly I
19. the data the displayed new measurement and relative value is red color Press it again to quit The hold function and the relative value be combined use the display value is yellow The meter protection gt Voltage protection You can t input the voltage which more than 660V AC it s possible to show higher voltage but it s may destroy the inner circuit gt Resistance Continuity Diode PTC component Protection Wrong input voltage will Auto enter protection state It only suitable for short and limit time work If input voltage over 600V will damage the meter gt mA current fuse range 250V 1A if the current over the rated range fuse will melt to protect the meter Pls use the same model when change the fuse Pls opens the battery cover to change A Note 10A socket without fuse protection if over the current range Wrong using the 10A socket to measure the voltage will damage the meter 3 3 18 Media Player Click the icon to enter PLAY 16 56 00 dX ONVIFToolVideotape video 2000 01 02 02 05 43 mp4 ONVIFToolVideotape video 2015 01 23 17 29 38 mp4 ONVIFToolVideotape video 2015 04 23 15 42 07_mp4 ONVIFToolVideotape video 2015 04 23 15 48 40 mp4 66 UL The Media player can browse video and image files It supports the video formats of MP4 H 264 MPEG4 and MKV The IP tester s recorded files can play directly via the Media player The Media player will automatically display the video fil
20. the tester and then connect the tester with power adaptor to resume the tester 4 Make sure the tester is full charged or more than 80 otherwise the tester will shows low 99 ce power not able to supply power 3 3 27 Application tools Click the icon fre o open the Application Tools folder This folder contains useful apps such as POOL Audio Recording DHCP Server Network test Notepad Link monitor and RTSP Player 9 10 15 gt NOTE p MANUAL Update 7 7601 Audio Record Connect an audio device t the IP tester s audio input port Click the con E to enter TAPE the Audio Recorder app Click the red button to stop and the unit will prompt you to save the recording Net work test Ethernet bandwidth test To use the Network tester you will need two IP testers One is used as a Server and the other as a Client z n Both devices must be on the same network segment in order to communicate Click the icon open the Network Tester app Note Network test results only used as a reference For more accurate test please use a professional Ethernet tester I Network test N P 17 08 59 amp Service IP 192 168 0 238 h 92 168 0 238 When test need a a tester or a computer installed Network Test Software as the Server the other tester sends packet test The two testers must be in the same network segment 1 Start the server Click Start Server button to u
21. voltage 0 3 4 66 00V mV 10mV 660 0V 100mV AC voltage 93 560 0m Mavala TaS 6 600V ImV 660 0V 100mV DC current 6 600mA luA 66 00mA 0 5 3 10uA 660 0mA 100uA AC current 6 600mA luA 66 00mA 0 5 3 10uA 660 0mA 100uA Resistance 660 0Q 0 8 5 0 12 66 00KQ 10Q S94 TL 660 0KQ 100Q 660M2 600MQ 66MQ CL 2 5 10KQ Continuity 660 0Q 0 1Q The measurement value less 300Q 3Q the tester will sound Diode Schottky diode 0 15 0 25V 2 0V ImV rectifier diode 0 6 1 0V triode PN junction 0 5 0 8V Capacitance 6 600nF 0 5 20 66 00nF 10pF 660 0nF 100pF 3 5 8 660 0uF 100nF 6 600mF 5 8 66 00mF _ 395 WL 4 3 Optical power meter specifications Measure Range dBm 70 10dBm Wavelength nm 850nm 1300nm 1310nm 1490nm 1550nm 1625nm lt 3 dB 10dBm 22 C Uncertainly lt 45 dB full range 22 C 4 4 Visual fault locator specifications Output power 5mW optional 10mW 20mW Modulation mode CW 1Hz 2Hz The data above is only for reference and any change of them will not be informed in advance For more detailed technical inquiries please feel free to call the Technical Department of our company 96 WL
22. 02 05 43 mp Rename 17 29 38 mp Delete ON vir sour viueUidpe s viUeUs LU i o u4 29 15 42 07 mp ONVIFToolVideotape video 2015 04 23 15 48 40 mp4 A Video files can play in the Video player of the main menu 3 3 4 IP camera test Click icons eae enter IP camera test The IPC Test app is used for IP cameras that are fully integrated by name with the IP tester If the IP camera s video stream is MPEG4 use the IPC Test SD mode If your IP camera s video stream is H 264 use IPC HD High Definition Display high definition images support snapshot video record and playback Currently the IPC tester only support some brands specified IP cameras the brands include Dahua Hikvision Kodak Samsung etc OEM service is available Clients can send us the IP camera or mobile client Android version APK files for our engineers to try to add the protocol to the IPC tester A Note Currently the IPC Test App only supports some brands specific IP cameras these include specific models made by ACTI AXIS Dahua Hikvision Samsung SecurityTronix and many more If the camera is not fully integrated please use the ONVIF or RTSP apps 41 IPC test interface IPC Test w a 16 45 53 X Local IP 192 168 0 221 Edit IP camera type HIKVISION_DS 2CD864 E13 Manual IPC Cameras IP 192 168 0 64 search IPC User Name admin IPC Password IPC Port 5198 Enter Restore Local IP This is the tester s IP address
23. 080P 30FPS 1920x1080P 30fps 1 Coaxial PTZ control Click the icon PTZ on the right toolbar Port Select Coaxial control E aho Port UTC Sg Coaxitr ie AS485 RS2352 Cancel 2 Click the screen to set PTZ address parameters Port Coaxitron OK 3 If coaxial control PTZ control of the AHD camera it does not need to set the parameters 4 More details Pls referto 3 3 6 CVI camera test 3 3 9 IP address scan Connect the cable to the LAN port click icon to enter set initial IP and destination IP address i the tester s IP address network segment can be the same or different to the scanned network device s network segment then click the key Start to scan quickly to search the IP address also can input the IP address in the Port Number Scan to scan to port number check the tested device s supporting port number and how many ports can support the device s network communication a 16 47 34 X Scan IP ACACA PEE Port Number Scan Please enter the IP address IP addresses Start E520 3 3 10 PING Test PING is the most conventional network debugging tool it is used for testing if the connected IP camera or other network equipment s Ethernet port is working normally and the IP address is correct Connect a network cable to the LAN port and click the icon to open the PING tool You can set your LOCAL native IP address Remote IP addre
24. 28 X service IP 192 168 0 232 192 168 0 238 9 5 0 6 0 sec 9 85 MBytes 82 7 Mbits sec 9 6 0 7 0 sec 10 2 MBytes 85 3 Mbits sec 9 7 0 8 0 sec 10 1 MBytes 85 1 Mbits sec 9 8 0 9 0 sec 10 2 MBytes 85 3 Mbits sec 9 9 0 10 0 sec 9 95 MBytes 83 4 Mbits sec 9 0 0 10 0 sec 97 9 MBytes 82 0 Mbits sec DHCP server Click on the DHCP icon to open the DHCP server app Select the Start check box at the top and make any desired changes to the network settings Click Save to start assigning dynamic IP addresses for IP cameras and other networked devices Click the Refresh button to check your Client list Refresh to check received IP address S80 NL Die 17 06 44 X onop The router built in DHCP server to automatically configure each calculated area network TCP TP protocol ry MD a DHCP server i a Stop Start Local address 192 168 0 238 a Adress pool Initial IP 192 168 0 20 Adress pool End IP 192 168 0 254 m A A Tf 29oc on TY hh ry i Ta LA mir Address lease Adress lease min 1 2880 minfactory default 60 mi Gateways 192 168 0 1 DNS server 129 219 13 81 Client list Notepad Click on the Notepad icon to open the Notepad app Click the Save key to save the contents 16 01 01 2 pls m E to view the notepad all saving contents display Click each record bar to show the details Press the record bar for several seconds prompt whether delete it
25. 7 iiaa bod OR Scan IP Cancel Local IP This is the IP testers IP address RTSP Add This is where you can manually enter the IP camera s RTSP URL or click on Search to search the network for cameras that use an RTSP stream IPC Username Enter the IP camera s user name IPC Password Enter the IP camera s password Once you have entered all the necessary information select Enter at the bottom left to view the RTSP stream 830 E Please select stream Main stream 192001060 JPEG Secondary stream 740480 H264 Cancel NOTE IN THE EVENT THE IP TESTER DOES NOT AUTO DETECT THE RTSP STREAM REFER TO THE SPECIFIC CAMERA MANUFACTURER FOR THE SPECIFIC RTSP STREAM URL YOU MAY FIND THIS ON LINE WITH A SEARCH OF THE CAMERA MODEL NUMBER AND THE WORD RTSP Trace route Traceroute is used to determine path of the IP packet access target Note Trace route testing results only for reference for accurate test route tracking Pls use professional Ethernet tester Click to enter Network bandwidth testing Input tracking IP address or domain name in the Remote Host IP Set maximum hop count normally default is 30 OREN ROG ZE 16 54 00 S84 Tl Click start to trace the goal address Q Trace Route 16 52 30 192 168 0 225 Tracerout to 180 97 33 107 180 97 33 107 30 hops max 30 byte packets 1 192 168 0 1 1 163ms 575 221 ms 978 699 ms 2 192 168 1 1 1 232 ms 488 535ms 979 588 ms 3 100 64
26. Click Edit to enter IP setting and change the tester s IP address settings IP camera type Click IP camera type list Honeywell Honeywell Kodak Tiandy Aipu waton VVS ACTi WoshiDA IP camera etc If the brand has offered official original protocols Pls select camera type input IP camera address user name and password click official to enter the camera image display interface Currently only support DAHUA official protocols IPC Camera s address Enter IP camera s IP address click deploy to add IP address of the Different network segments support multi network segments IP camera test Click Search to auto scan the IP camera s IP address and display It is better to directly connect IP camera to the tester so that the tester will search out only one IP address If the tester is connected to PoE switch it will search out several IP address IPC User Name Enter IP camera s user name IPC Password Enter IP camera s login password if default enter password not show relevant letters click display to show the passord IPC Port No Select IP camera type it default relative camera port number and not need change After setting click Enter to enter image interface 42 Tl IPC Test 1920x1080 J P W 16 46 17 X 2015 04 27 10 42 21 Snapshot r rie Record If IP address setting has error or IP camera is not connected The tester prompts Network Error Click Ea to
27. IP camera tester USER MANUAL IPC1 03 Thank you for purchasing the IP camera tester Please read the manual before using the IP camera tester and use properly For using the IP camera tester safely please first read the Safety Information carefully in the manual The manual should be kept well in case of reference Keep the S N label for after sale service within warranty period Product without S N label will be charged for repair service If there is any question or problem while using the IP camera tester or damages occurred on the product please contact our technical Department Content 1 Safety information l 2 IP Camera Tester Introduction 2 2 1 General 2 2 2 Features 3 2 3 Function 5 2 4 Packing list 11 2 5 Function introduction 12 3 Operation
28. Set the pan speed of PTZ camera 0 63 2301 F Tilt speed Set the tilt speed of PTZ camera 0 63 G Set preset position Set PS Click and select Set PS set and save preset position number 1 128 H Call the preset position Go ps Click and select Set PS set and save preset position number 1 128 click sure to save Call some special preset number can call the dome camera menu A Check and set the protocols address interface and baud all must be consistent with the dome camera dome camera then the IPC tester can test After setting the parameter the tester can control the PTZ and lens To control PTZ by screen touch Tap left right upward and downward on the touch screen to control the PTZ rotation direction By two fingers move outward and inward on the touch screen to zoom in and out the PTZ E 16 34 43 Press the key CVD 4D A Pl the PTZ direction of rotation Press or aa to switch on or turn off the aperture Press aA or a adjust the focus manually Press or manually adjust the zoom TELE B24 TL 3 3 1 2 Video and storage setting Click icon set to enter and set analog video image brightness contrast color saturation as well as the file storage way after snapshot and recording support auto storage and manual storage When select manual storage user can name and store the files 16 34 12 gt Mode Off Snapshot mr ry Saturation Record Gray Scale g
29. appears on the screen and begins to flash and a timer appears indicating the time elapsed for the video Click on the Record icon again to stop recording and save the video file to the SD card if select manual storage before recording begins appears dialog box Input Name user defined the files name by Chinese character English letter or digit to store in SD card tester will hereby store the 2601 files in SD card after recording if select Auto storage tester will auto store the files in SD card after recording gt 17 16 05 gt X 2015 04 27 10 42 21 cy 00 03 snapshot 3 3 1 6 Photo Click the icon photo to enter click the selected thumbnail photo to display it on the screen Double tap the image you want to view to make it full screen Double click again the photo to return fA Photo Browser 4 eG 16 35 54 2 m S l To rename or delete an image click and hold on the file until this screen below appears 27 7 16 36 04 2 Rename Delete Click to close and return to PTZ controller 3 3 1 7 Record playback Click icon playback to enter Click the Playback icon to view your recorded videos Tap on the video file image you want to watch 7 16 56 00 2 ONVIFToolVideotape video 2000 01 02 02 05 43 mp4 ONVIFToolVideotape video 2015 01 23 17 29 38 mp4 ONVIFToolVideotape video 201 5 04 23 15 42 07 mp4 ONVIFToolVideotape video 2015 04 23 15 48 40 mp4 To rename or
30. asuring Q Resistance Measuring Diode Testing U AC Voltage Measuring A AC Current Measuring Naar Continuity Testing T Capacitance Measuring AC DC Voltage and current measurement state display The Multimeter auto adjust the range by input signal or tested components Data hold Hold data Relative Display the relative measurement value measurement Press the key to change display state 10A socket In 10A current measurement state indicate use 10A socket The current measurement value over the range if in the Auto range state to Over range switch Auto 3 OPERATING INSTRUCTION DC Voltage Measuring a Connect the black test lead to the COM jack and the red test lead to the V Q jack b Select U enter the DC voltage measurement c the tester default Auto range status by click DC auto range press the key can select manual range and restore auto range Manual range 0 000V gt _ 6 600V range 00 00V gt 66 00V range 000 0V gt 660 0V range 000 0mV gt 660 0mV rang 610 AC Voltage Measuring a Connect the black test lead to the COM jack and the red test lead to the V Q jack b select U enter the AC voltage measurement C the tester default Auto range status by click AC auto range d Manual range can be select press the key NEAR to restore Auto range e Manual range 0 000V gt _ 6 600V range 00 00V gt 66 00V range 000 0V gt 660 0V ra
31. ble s length and short circuits location It improves working efficiency 2 3 32 FTP Server Start the tester s Wi Fi or connect the tester s LAN port to the network Once the tester is online start its FTP Server and directly access files from the tester s SD card This also allows for the user to upgrade the tester firmware 1001 2 4 2 4 Packing list 1 Tester 2 Adaptor DC12V 1A 3 Network cable tester 4 Polymer lithium ion battery 3 7V DC 3000mAh_ 5 BNC cable 6 RS485 cable 7 SC ST connector Only for optical power meter 8 Multi meter test leads one pair of red and black only for the Multi meter models 9 Camera powering cable 10 Audio cable 11 TDR alligator clamp only for TDR models 12 Safety cord 13 Tool bag 14 User s Manual 15 4GB SD card 1101 2 5 Function introduction 127 6 Press more than 2 seconds turn on or off the device short press to turn on or off the menu display 2 SET Set key f 3 MODE Menu key 4 Near focus Focus the image nearby 5 ka Far focus Focus the image faraway 6 TELE zoom in the image T WIDE zoom out the image 8 Open set Confirm the setting of parameters open or enlarge the aperture Return Close Return or cancel while setting parameters of the menu close or es decrease the aperture 10 Q gt Upward set function or add parameter Tilt the PTZ upward Rightward select the parameter whose value will be changed Add t
32. ddress is not known the device cannot be used An IP address scan can quickly search for the connected IP camera or other network device s IP address lt The PoE voltage test can test for PoE voltage when a POE switch is supplying POE power to an IP camera TDR cable test test cable length and short circuit Optional Cable test Tests LAN cable sequence of wires Support RS232 RS485 Rate 600 115200bps adjustable PTZ protocol analysis control protocol command displays to check RS485 transmission whether is normal easy to find the fault device PTZ control Pan tilts the P T unit zooms in out the lens adjusts the focus aperture and sets and the preset position DC12V 1A output power for cameras Audio input t test 3 7V 3000mAh Lithium Ion Polymer Battery can lasts 10 hours for normal use after charging for 4 5 hours remaining battery charge indicator Sign means the function optional W P H 2 3 Function 2 3 1 Touch screen and OSD menu The IP camera tester combines touch screen control and physical buttons This combination makes the tester very user friendly The test meter allows you to move the function icons from the tester s main menu to the APPS tool folder or move them back to customize the main menu 2 3 2 WIFI Built in WIFI can receive wireless camera ONVIF and customize camera or network data etc 2 3 3 IP camera test The device is designed for ONVIF IP camera testing It can d
33. delete a video click and hold on the file until this screen appears 2801 Video player x 16 56 08 amp Mar ONVIFToolVideotape video 2000 01 02 02 05 43 mp4 Rename 17 29 38 mp4 Delete ON virrvoi VIUCULAPE VIUCUs LU I VTU LT 15 42 07 mp4 ONVIFToolVideotape video 2015 04 23 15 48 40 mp4 Video files also can play in the main menu Video Player 3 3 1 8 Video level meter optional Click the icon to enter the IP camera tester has adopted hardware high speed sampling and processing technology enable it to achieve more accurate measurements in the video signal PEAK SYNC level COLOR BURST chroma level When the video signal is input the tester auto test and display the measurement on the left bottom corner of the screen Video level Peak level 0 Sync level 0 Waa level tH While in PAL format the unit will be mV While in NTSC format it will be IRE 29 Tl Video Level Peak o peak leve NTSC 140 IRE PAL 1000 mY Widead ZUIRE PHLPHASSPSPSSHHE PESTER Ee Burst Level HRE i 20RE 22sfeeneeneene at ADIRE Sy t Level peak 10 p eaki NTSC 40 IRE PAL 265 7 mW Video signal level 140 15IRE Chroma level COLOR BURST 40 5IRE Sync Level Syne Laval J SYNC signal level 40 45IRE Video signal level 1000 200mV PAL Chroma level COLOR BURST 300 35mV SYNC signal level 300 35mV Video signal PEAK to PEAK level For NTSC format the video
34. dress scan off or on before entering the PTZ controller app This needs to be turned on in order to use the PTZ Scan feature of the PTZ app Turn off option If you select Fast turn off the tester will shut down faster but data will not saved To avoid unnecessary problems it is recommended not to use the Fast turn off option 88 0 3 3 30 Update to enter Local update 17 08 39 X Current version V01 00 012 _ System Update UPDAT Update Updated version V01 00 010 r Current version V01 00 067 IPC Test Update Increase the user name password history feature Current version V01 00 005 Update All If there are applications for updating the applications will be displayed on the interface Click the relevant applications to update to the latest version 3 4 DC12V 1A power output Touch B fucntion enter power output interface When the IP tester is turned on the 12VDC power output ON by default The smaller end of the supplied converter cable connects to the tester s DC12V 1A OUTPUT and the other end connects to the camera s power input Power output function is mainly used in the camera field demonstration and testing meanwhile for some camera installation sites if the camera is no power the tester can offer temporary power for it But we do not suggest tester supply power for a long time FALU A Notice a Don t input any power into the DC12
35. e display may be delayed While in HD mode if the network camera stream is H 264 the tester can fluently display the image up to 1080P Click icon lt J to enter Then tap either the ONVIF icon is for SD mode MPEG4 and the ONVIF HD icon is for HD mode H 264 320 Click icon to enter the tester Auto Scan different network segments ONVIF cameras and list the camera name and address on the screen left Some cameras not need user name and password to login Please select Non verification to login the camera Device List 4 EVC 20EVC E271 Serial 1 192 168 0 101 80 Location 92 168 0 188 Location country chi Location country chi ONVIF Serial 4 92 168 0 201 80 Add Refres If you select ONVIF SD or HD mode the meter automatically scans different network segments for ONVIF cameras It lists the camera name and IP address on the Device List If no cameras appear under the device list try clicking on the Refresh button SJ ONVIF 16 40 59 X Add device http 192 168 0 1 onvif device_service OK Cancel Locatio ONVIF Serial 4 192 168 Add Refres Click refresh the IPC tester scanned ONVIF network camera on the internet Click the camera in the list of devices camera login window pops up Input the camera s username and 53300 pass word Some network cameras does not require a user name and password authentication check non verification and
36. e in SD card if select Auto recording the tester auto recording the files after screenshots Record When you click the Record icon video starts recording A red recording icon appears on the screen and begins to flash and a timer appears indicating the time elapsed for the video Click on the Stop icon to stop recording and save the video file to the SD card ONVIF Device List 4 EVC 20EVC E271 Serial 192 168 0 101 80 Location Dahua Serial 2 192 168 0 188 ocation country chi Serial 4 192 168 0 201 80 Add h Refres Main Stream 1920x H264 General Live video Identification Time Set Maintenance Network Set User Set NTV gt Playback Video Set Imaging Set Profiles Preview ibtype O0 amp unica 390 Set Click icon Set Photo and record function can select if Auto name Photos and recording files Auto storage if manual user define files name Playback Click the Playback icon to view saved videos Double click the video you want to play Click to return to the last menu Vi Te YoMl 8 ENE E 16 45 04 X ONVIFToolVideotape video 2000 01 02 02 05 43 mp ONVIFToolVideotape video 2015 01 23 17 29 38 mp ONVIFToolVideotape video 2015 04 23 15 42 07 mp ONVIFToolVideotape video 2015 04 23 15 48 40 mp4 To rename or delete a photo click and hold on the file until this screen appears S40 TL ere 16 45 14 X ONVIFToolVideotape video 2000 01 02
37. easy to remove the soft cloth with water or neutral detergent can be used But the cloth should be tweaked sufficiently About Digital Multi meter Before using you must select the right input jack function and range Never exceed the protection limit values indicated in specifications for each range of measurement When the tester is linked to a measurement circuit do not touch unused terminals Do not measure voltage if the voltage on the terminals exceeds 660V above earth ground At the manual range when the value scale to be measured is unknown beforehand set the range selector at the highest position Always be careful when working with voltages above 60V DC or 40V AC keep fingers behind the probe barriers while measuring s Never connect the meter with any voltage source while the function switch is in the current resistance capacitance diode continuity otherwise it will damage the meter Never perform capacitance measurements unless the capacitor to be measured has been discharged fully Never measure any of resistance capacitance diode or continuity measurements on live circuits Visual laser sources When you turn on visual laser sources please don t stare at it or will damage to eyes When not using it Please turn it off and cover the protective cap 2 IP Camera Tester Introduction 2 1 General The 3 5 inch touch screen IP camera monitor and tester is designed for maintenance and installatio
38. es from the SD card Click on the desired file to play Click RETURN to exit To rename or delete an existing file press the file name for a few seconds until the screen below appears You can then rename or delete the file by pressing the desired option Video player ot A141136 X sy ae gt privatevideo 2014 11 12 14 13 16 mp4 nee a Hja privatevide s aw toe e ie pe Rename Delete 38 53 mp4 iz privatevideo 2014 11 12 14 44 41 mp4 i privatevideo 2014 11 12 14 49 36 mp4 3 3 19 Audio player 4 Click the icon to enter The audio player only supports MP3 format Audio files J Audio Player E 16 56 30 X 2015 04 24 11 2015 04 24 11 46 22 mp3 g 46 22 mp3 5 22 mp3 Falling eq Slowly mp3 mp PE E x Valder esq Fields mp3 mp i o d 3 ENOS B67 Ul 3 3 20 LED Flashlight _8 It is convenient for the installation or maintenance in the evening or in the dark Click icon S to af enter H a E 16 58 09 3 Lighting Mode While in the flashlight app click the red button to turn on the LED lamp Press it again to turn it off If Time setting you don t press the red button to shut off the lamp and press the button to exit the app the lamp will stay on Click the Time Setting button to set a timer that will shut off the lamp 3 3 21 PoE PSE Voltage test Click icon Ficon to enter the PoE voltage in line measurement app Me W 16 58 52 2 oO
39. f the level is too high it will lead to a poor quality COLOR BURST level Testing the color burst level will determine if the burst signal is sufficient to trigger the displays color producing circuit Burst will diminish in amplitude over longer cable runs and can get fall below the threshold for the video display to show a color image For NTSC format the Chroma standard level is 40 IRE For PAL format the Chroma standard level is 280mV If the Chroma level is too low the color will not be as deep and some details of the image will get washed out If the Chroma level is too high there will be spots on the image If the coaxial cable is too long it will reduce the chroma level 2 3 7 PTZ controller Display the input video images Pan tilt the P T unit and zoom in out the image Setup the controlling parameters like protocol communication port baud rate PTZ ID pan tilt speed set and call preset position 2 3 8 Enhanced Color bar generator The tester sends out color bars via its BNC output to the monitor This is used to test for a problem in the cable going from the camera back to the monitoring area 2 3 9 DC12V 1A power output Power the camera with DC12V 1A power output from the tester It is helpful for demo and testing when the power supply is not available 2 3 10 Audio testing Test the audio from mic level input devices Connect the tester and mic level device with the audio cable Supports audio recording and output t
40. he link indicator of the tester s LAN port is green and the data indicator flickers it means the IP camera and the IP tester are communicating If the two indicators don t flicker check if the IP camera is powered on or the network cable is not functioning properly 1701 A Warning PoE switch or PSE power sourcing equipment only can be connected to tester PSE IN port or damage the instruments 3 2 2 Analog camera test mi e I je wN Eh 1 The camera or dome video output is connected to CCTV Tester VIDEO IN the image display on the tester 2 CCTV Tester VIDEO OUT interface connect to the Video input of monitor and optical video transmitter and receiver the image display on the tester and monitor 3 Connect the camera or the speed dome RS485 controller cable to the tester RS485 interface Note positive and negative connection of the cable Support RS232 PTZ controller connect the RS232cable to RS232 interface of the tester 3 2 3 HD Coaxial camera connection SDI CVI TVI AHD camera are HD coaxial camera The manual description is optional function SDI as a case SDI TVI CVI and AHD camera connection way is the same 1801 1 Connect SDI camera to tester s SDI IN interface when there is image input it will display on the screen Note Tester only with SDI input No SDI output function 2 Connect the SDI camera or RS485 control cable to Tester s RS485 port Note positive a
41. he value of the parameter Pan the PTZ right 12 Q Leftward select the parameter whose value will be changed Downward set function or reduce the value of the parameter Tilt the PTZ downward 14 Open set Confirm the setting of parameters open or enlarge the aperture 15 Snapshot 16 Cr Video record 17 Ge LED lamp 18 e Confirm key Return Close Return or cancel while setting parameters of the menu close or decrease the aperture 20 Multimeter interface 13W The power indicator it lights green while the tester is powered on by the adapter The data accepted indicator it lights red while the data is being received The RS485 RS232 data transmission indicator it lights red while the data is being transmitted The charge indicator it lights red while the battery is being charged As the charging is complete the indicator turns off automatically Top interface Left interface Right interface 1401 Video image signal input BNC interface Video image signal output BNC interface cable scan interface Visible red laser source emits Interface TDR cable test interface SDI AHD CVI and TVI input BNC interface DC12V1A power output for provisional DC power supply Not support RS232 communication LED flashlight RS485 Interface RS485communication for the PTZ Lan test interface PSE power sourcing equipment Tests PoE voltage Audio input Reset key 1501 UTP cable port UTP cable tester po
42. isplay the image from an IP camera and change the IP address The 3 5 inch 480x320screen display allows the user to view the image with a sufficient screen size With the ONVIF tool you can display the image from an IP camera and use the PTZ functions Currently the IP camera tester supports more than 70 brands IP cameras such as most ACTi Dahua Hikvision Samsung Honeywell and many more OEM service is available Users can send us the ip camera video management software for our engineers try to add the protocol to the tester 2 3 4 SDI camera test optional SDI digital video surveillance testing support 720p 60fps 1080p 30fps 1080i 60fps digital camera image test and video image zoom record screen snapshot Photo viewer and playback 2 3 27 CVI camera test Optional CVI camera tester support720p 25 30 50 60fps 1080p 25 30fps when CVI signal input HD CVI camera image display zoom view photos video record and playback Coaxial PTZ control and call up the camera OSD menu W 2 3 28 TVI camera test Optional TVI camera tester support720p 25 30 50 60fps 1080p 25 30fps when TVI signal input HD CVI camera image display zoom view photos video record and playback Coaxial PTZ control and call up the camera OSD menu 2 3 29 AHD camera test Optional AHD camera tester support 720p 25 30fps 1080p 25 30fps when AHD signal input HD CVI camera image display zoom view photos video
43. ks in your area Select the desired wireless network SSID and enter your password to connect Close the wifi Brightness Set the desired brightness of the IP tester and adjust the sleep time settings Volume Change volume levels SD Card Displays SD Card Capacity You can also format the SD card or unmount it before removing it FTP serve Once the IPC tester connects to a network a computer can be used to read the SD card files via FTP 87 14 45 50 Xe T oP 14 46 55 X Start the FTP server and then input the tester s FTP address in the PC s address bar ftp as ftp 192 168 0 233 2121 This will enable the PC to read copy and edit the files from the SD card without the use of SD card reader it Bem p T T L TE a a f bk rte L a L i oe L kisema L B _ B R p jz m Bse amp k aa i TH iz L Cn E L k L 3 a am manon adii Fi mOr E ii 2 Th eel Fi LS aE Fi ah ate fun J erimi t fi fe ny ag et Pi ete ead rmai m yours 2 Pommes Lb Lon asi aims oA Mee i ase Rs ON ee A E e B pisi a is d eiii Ea as Version information This displays the version information for each application Screen rotation Click on Screen Rotation to flip the IP tester s display 180 degrees This function is very convenient for the user to connect the LAN cable on the bottom of the unit without having to flip the unit itself PTZ address scan You can toggle the PTZ Ad
44. mage display zoom video record and playback Coaxial PTZ control and call camera OSD menu Optional Analog camera video display Auto adapts and displays the video in NTSC PAL formats Support more than 30 protocols such as PELCO P PELCO D SAMSUNG etc PEAK video signal level SYNC signal level Color burst chroma level measurement test video signal attenuation Video image digital zoom to view the image in greater detail Snapshot function allows you to save the current image as a JPG file in the SD card Video recording and playback LED Flashlight 4GB Micro SD card included LCD screen brightness contrast color Saturation adjustable Visual fault locator to test fiber s bending and breakage Optional Optical power meter test fiber loss and value Optional Digital Multi meter DC and AC voltage measurement Resistance measurement Optional a S Enhanced Color bar generator PAL NTSC multi system color bar video generator Eight system switchable transmit receive eight system colorful images lt Cable tracing by sending an audio signal This enables the blue cable tracer to find the connected cable from a bundle Optional lt Ping test PING is the most conventional network debugging tool it is used for testing if the connected IP camera or other network equipment s Ethernet port 1s working normally and the IP address is correct lt In digital IP surveillance applications if the IP camera s IP a
45. meters more than 50 meters click Cable Type to select user defined 1 for calibration 11 groups user defined can be Set 15 46 24 e Length Om Number Type Wave velocity 1 SYV 75 5 207 SYV 3 3 207 SYV 5 2 200 2 3 4 RVVP 160 5 AAAY 178 1 Select user defined and click Calibration to enter test click user defined 1 can define cable name suchas AiPu BNC 5 7001 IE 15 46 37 X Length Om User defined3 SYV 9 2 fy Calibration 2 Click Cable Type to select cable and corresponding type for example if testing BNC cable select BNC if testing communiction cable 75 2 select SYV 75 2 Select type of Cable SYV 75 2 Cable Ethernet cable TVVB 3 Other 3 Click or to adjust wave speed while display length is the same with the actual Length click Save to save calibration data It can be used for the same cable testing next time 7101 15 46 37 X Length Om User defined3 SYV 9 2 fu Calibration Application TDR test is the use of pulse reflection method to transmit pulse signal for tested cable when cable is disconnected or short circuit reflected pulse is generated the tester receives and deals with the reflected wave measurement results displayed on the screen TDR cable test can test cable length and short circuit help engineer quickly find the cable s problem location It is m
46. n of IP cameras and analog cameras as well as other security equipment The 480x320resolution enables it to display network HD cameras and analog cameras in high resolution The unit supports many ONVIF PTZ and analog PTZ control The combination of touch screen and key buttons make the IP camera tester very user friendly The tester is also a great tool for Ethernet network testing It can test PoE power voltage PING and IP address searching You can use the blue cable tracer to locate individual connected cables from a bundle of cables Test LAN cable for proper connection termination LED Flashlight DC 12V 1A power output and much more Its portability user friendly design and many other functions make the IP tester an essential tool for all installers or technicians 2 2 Features gt gt 4 3 5inch 480320 touch screen easy to operate ONVIF IP camera video testing Compatible with H 264 MPEG4 MJPEG IP cameras such as Dahua HIK VISION and ACTI Customized service is available Built in Wi Fi receives video from wireless cameras or ONVIF cameras connected to the network SDI Digital camera image display record and screen snapshot Optional HD CVI camera image display zoom video record and playback Coaxial PTZ control and call camera OSD menu Optional HD TVI camera image display zoom video record and playback Coaxial PTZ control and call camera OSD menu Optional AHD camera i
47. nd negative connection of the cable Support RS232 PTZ controller connect the RS232cable to RS232 interface of the tester 3 3 OSD menu m Press the key ob 2 seconds to turn on mM Press the key ob 2 seconds to turn off E short press the key ob to enter sleep mode press it again to test if tester work abnormally and cannot be turned off Press the key CO J eeveral seconds to turn off the tester reset 1971 Multifunction Tester il PTZ TV OUT IPC viewer Browser a Select Icons to enter if quit Please click Multifunction Tester eee oP FOL SCAN PING Port flashing POE Power Out Cable Sear 2 Click SD card install or remove SD car Multifunction Tester Ok Cancel IPC viewer Browser a S20 IPC Test f a GB28181 Cable Tester Ea TDR IPC Test f a GB28181 Press function Icons seconds tip whether move this icon to APPS file if some function not be often used can move these function icons to APPS Multifunction Tester 7015 04 27 16 33 00 IPC Test IPC viewer Browser GB28181 a Click icon APPS tool to show all collected function icons Click 5 back to the tester s main menu Multifunction Tester Me 2014 12 30 16 21 39 In APPS file Select icon and press it for seconds tip whether move the file to the desktop 210 Multifunction Tester Ma 2014 12 30 16 21 45 3 3 1 Video monitor test PTZ c
48. nge 000 0mV gt 660 0mV range DC Current Measuring only manual range A WARNING Shut down the power of the tested circuit and then connect the meter with the circuit for measurement a Connect the black test lead to the COM jack and the red test lead to the mA jack for a maximum of 660mA current For a maximum of 10A move the red lead to the 10A jack b select A enter the DC current measurement the screen display DC current can select manual range c Manual range 0 000mA gt _ 6 6mA range 00 00mA gt 66 00mA range 000 0mA gt 660 0mA range 00 00A 10 00A range use 10A socket d Select the range to enter current measurement A Note When only the figure OL is displayed it indicates over range situation and the higher range has to 62 UL be selected When the value scale to be measured is unknown beforehand set the range selector at the highest position The maximum current of mA socket is 660mA over current will destroy the fuse and will damage the meter The maximum current of 10A socket is 10A over current will destroy the meter and will damage the operator In AC mode only can input AC if not will damage the meter Resistance Measuring A WARNING When measuring in circuit resistance be sure the circuit under test has all power removed and that all capacitors have discharged fully a Connect the black test lead to the COM
49. nly be modified main stream Brightness Contrast Sharpness Profiles Click profiles can view video streaming current configuration files as well as switch between Major stream and minor stream 360 lika Please select stream Main Stream Stream Preview pictures Quickly preview and zoom in or out pictures automatically and manual refresh Sd ONVIF Device List 4 EVC 20EVC E271 Location country chi ONVIF Serial 4 192 168 0 201 80 Add Refres h 16 43 48 X General Preview Identification Time Set Maintenance Network Set User Set NTV Live video Video Set Imaging Set Profiles v auto refresh double click on the h screen to zoom Refres 37W ONVIF ONY Device List 4 EVC 20EVC E271 192 168 0 190 Location country chi h General Identification Time Set Maintenance User Set NTV Live video Video Set Imaging Set Profiles Preview Network Set DHCP IP Address Subnet mask Default gate Host name DNS NTP servers 16 44 03 X off 192 168 0 190 255 255 255 0 192 168 0 1 DVR 8 8 8 8 10 1 1 1 Zoom in image press thef key to enter the zoom mode Press it again to exit zoom mode oun When the image is enlarged tap left right up or down on the image to move the whole image on the screen ONVIF Device List 4 EVC 20EVC E271 Location country chi ONVIF Serial 4 192 168 0 201 80 Add Refre
50. o adjacent or crossing cables however the cable that makes the loudest noise is the one that s connected to the meter 3 3 13 Port finder Connect a network cable to the meter s LAN port click the 23 icon to open the Port Flashing app S55 00 Click Start The IP tester sends a unique signal to make the connected LAN port of the switch flash F Port Flashing a 1 15 45 27 X If the tester and PoE switch are connected well the LAN port of POE switch flash at special frequency If not no any changes on the LAN port B Port Flashing eo f 15 45 46 X Application The tester will send special signals to make the connected LAN port flicker at special frequency which will enable the installers to easily and quickly find the connected Ethernet cable This function can prevent mistakenly insertion or disconnection non corresponding cable to artificially interrupt network connection 56W 3 3 14 Data monitor Pls click icon to enter DATA 15 50 54 gt Baud Advanced 5200 19200 9600 uea S HEX Show 4800 Send Cancel Setting Click Setting to choose the baud rate of RS485 RS232 it must be the same as the DVR or the Control keyboard The DVR or Control keyboard send the code to the tester if it can be read the protocol will shown on the upper right like Pelco D if not like P When the tester receives the code Press the key to clear screen Though the RS485
51. o monitor and or record audio 2 3 11 Cable tester a N gt Test LAN cable or telephone cable Connect LAN cable or telephone cable with the CCTV tester and cable tester And then the connecting status cable type and the sequence of wires will be displayed as well as display the serial number of the cable tester kit 2 3 12 PTZ data analysis Search the Control protocol code from Multifunction keyboard or DVR by RS485 RS232 interface test the PTZ control command data whether received anomaly and RS485 RS232 data transmission Screen displays 16 hexadecimal codes such as PELCO P A000 Add xx xxxxxx AF xx PELCO D FF 01 Add xx xxxxxxxx 2 3 13 Digital Image zoom on the monitor Set image zoom up to 4X to get a closer look at all the image detail Supports analog and many IP cameras 2 3 14 Video screenshot Capture the video image and save the current video image in the SD card 2 3 15 Record Capture the video frames as JPEG file and save the current video in the SD card 2 3 16 Playback Save video image and record files in the SD card Storage file directory can be created according to the date 2 3 17 Cable tracer optional Cable identification by use of an audio signal This function enables the blue cable tracer to find the connected cable from a bundle of cables with an audio tone 2 3 18 DHCP dynamic address assignment B uilt in DHCP server Dynamically assign IP address for the IP camera or net
52. on max 720p 25 Test Optional 30fps 1080p 25 30fps WIFI Built in WIFI soeeds150M connect to a wireless network and view IPcamera ONVIF ONVIF PTZ SecurityTronix Dahua IPC HFW2100P Hikvision IP camera type DS 2CD864 E13 Samsung SNZ 5200 Tiandy TD NC9200S2 Kodak IPC120L Honeywell HICC 2300T RTSP Viewer Customized welcome 1 channel BNC input amp 1 channel BNC looped output NTSC PAL Auto Video input output adapt Video Level Test Video signals measured in IRE or mV Video level meter PEAK video signal level SYNC signal level Color bar chroma level optional measurement Supports Analog and IP camera image zooming amp movement Snapshot Capture still images and record live video Media player will view photos and Video record and playback video playback 12V 1Apower output Output DC12V 1A power for camera 9101 1 channel audio signal input test whether sound normal 1 channel audio Audio test signal to connect headphone Support RS232 RS485 control Baud 600 115200bps Compatible with PTZ control more than 30 protocols such as PELCO D P Samsung Panasonic Lilin Yaan etc Video Signal Output one channel PAL NTSC color bar video signal for testing monitor or Generator video cable red green blue white and black color Local side PC can login the tester send the signal by network test network color bar generator connection communication whether normal Test UTP cable connection s
53. ontrol A Analog camera test and PTZ control click icon to enter 16 33 53 gt X Display the input video image click the top menu bar icon to enter video level meter PEAK level SYNC level COLOR BURST measurement Select relative function on the right side Toolbar to operate functions including Photos Snapshot 22 Record Playback PTZ Set Click to quit or press Mone back to menu Click the screen twice quickly can be full zoom in on the touch screen 3 3 1 1 PTZ controller parameter setting Select and click icon PTZ to enter PTZ setting Protocols Minking B01 Port RS485 Baud Rate 2400 Address 1 Horizontal Speed 40 Vertical Speed 40 Set Position 8 Call Position A OK Cancel A Protocol Use the up and down arrow keys to move the yellow cursor to the protocol set corresponding Protocol and support more than thirty PTZ protocols Such as Pelco D Samsung Yaan LiLin CSR600 Panasonic Sony EVI etc B Port Click and move to port Select the communication port for the PTZ camera controlling RS232 485 C Baud Move the yellow cursor to Baud Select the baud rate according to baud rate of the PTZ camera 150 300 600 1200 2400 4800 9600 19200 57600 1 15200 D Address Set the ID according the ID of PTZ camera 0 254 the setting address data must be consistent the speed dome address E Pan speed
54. ore convenient and efficient to repair the faulty cable A Note The TDR reflect signal could be affected by the cable quality cable s not well connected etc to cause the different TDR measurement The TDR measurement is for reference 3 3 23 Calculator Click icon iA to enter 72 TL 3 3 24 Browser Click icon g to enter Type in the camera s IP address and press Go to access the IP camera s interface A NOTE You will not be able to view live video in the web browser For viewing video use the IP tester live camera view apps 16 05 46 gt X Browse STR icra stern 192 168 0 190 Co Refresh 16 05 27 X ST hapy 102 168 0 190 Co Refresh IP camera ee eee t IP Camera The IP camera and IP tester must be on the same network segment for the browser to interface with the camera If they are not in the same segment click the button E press RETRUN to exit Open the Settings app from the main menu to change the IP tester s network settings to match those of the IP camera 3 3 25 IP camera viewer In addition to the ONVIF app or the IPC Test app you can use one of the mobile apps in the IPC Viewer folder but IP camera manufacturers can offer Video Management Software that compatible with mobile phone or tablet PC intall the Video Management Software in the tester enable the tester to display IP camera image by IP camera viewer Click icon IP camera viewer to enter run the Video
55. rt Cable tracer port DC12V1 5A charging interface Micro SD card moveable comes with 4GB supports up to 32GB 3 Operation 3 1 Installing the Battery The tester has built in lithium ion polymer rechargeable battery The battery cable inside battery cabin should be disconnected for safety during transportation Usually it doesn t need to disconnect the cable at the normal use Pressing the key CE continuously can power on or off the tester A Notice Pls use the original adaptor and connected cable of the device Ky When the battery icon is full or the charge indicator turns off automatically indicate the battery charging is completed A When the Charge Indicator L turns off the battery is approximately 90 charged The charging time can be extended for about 1 hour and the charging time within 12 hours will not damage the battery A Notice Press the key ob several seconds to restore the default settings when the instrument works abnormally Multi meter the red and black multi meter pen must insert the corresponding port A Warnings Instrument communication port is not permitted access circuit voltage over 6V otherwise damage the tester 1601 A Warnings Not allow insert multi meter pen in the current terminal to measure voltag 3 2 Instrument connection 3 2 1 IP camera connection Power an IP camera with an independent power supply then connect the IP camera to the IP tester s LAN port if t
56. s h Mat General Identification Time Set Maintenance Network Set User Set NTV Video Set Imaging Set Profiles Preview 1080 H264 Live video 16 42 48 X k m ltiple x100 annel 1 amp When the image is enlarged if not operate on touch screen it can operate by the keyboard press the key to zoon in press the key to zoom out press upward and downward key to move image A If it is network video input to the tester as the tester supports resolution up to 1080p the input image will be very clear after it is enlarged This is greatly helpful to help the installers to ensure the IP camera s video coverage and decide the IP camera s install site 238 00 Image can only be enlarged on SD mode The icon ONVIF is SD mode On the interface of Live Video click Video Menu appears toolbar Snapshot Record Photo Playback PTZ Set etc ONVIF Device List 4 EVC 20EVC E271 Serial 1 192 168 0 101 80 Main Stream 1920x 30 H264 Live video General identification Time Set Record Maintenance Network Set User Set Serial 4 192 168 0 201 80 Add Refres h NTV gt Playback Video Set Imaging Set Profiles Preview Snapshot Click snapshot to screen shots and storage if select manual recording appears dialog box Please input the files name user defined the files name by Chinese character English or digit to sav
57. s as well as the serial number of the cable tester kit will be displayed The number of the cable tester is 255 If need several different number other types cable testers should pay the additional cost 3 3 12 Cable tracer optional Connect a BNC cable to the Video Out port or connect a network cable to the UTP SCAN port Click the icon to open the Cable Search app To switch between the different audio tones select a number on the screen E54 fA Cable Search P 16 48 52 X tt Use the blue Combination cable identifier and network cable tester s copper pointer to touch all the cables in the bundle you are searching at the other end The cable that gives off the loudest tone is the cable connected to the tester Press the or buttons on your blue cable identifier to adjust the volume A Note Install two AAA batteries in your blue Cable Identifier Application It s convenient for people to find out the other end of the cable from the mess cable in security maintenance and network engineering While searching BNC cable connect one port of the alligator clips to the copper core or copper net of the BNC cable the other one to connect the earth wire barred windows A Note The battery of the cable tracer must according to corresponding positive pole and negative pole otherwise will damage the tester A Note While the cable tracer is receiving the audio signal from the tester it may be induced int
58. s displayed on top left corner of the image SAONVIF Mainsueam tsmce0H256 HM 9 16 42 35 36 Device List 4 General Live video EVC 20EVC E271 Serial 192 168 0 101 80 Time Set Location identification Maintenance Network Set 192 168 0 188 Location country chi User Set General Serial 3 192 168 0 190 ONVIF Serial 4 192 168 0 201 80 Imaging Set Profiles add Refres preview 90 554 cam realmonit Video Streaming Click Video Set to enter set the IP camera decoding resolution click OK to save 35 SR ONVIF Device List 4 EVC 20EVC E271 Add Pefies General Identification Time Set Maintenance Network Set User Set NTV Live video Imaging Set Profiles Preview a 16 43 00 X Video Set Main Stream Encoder and resolution Encoder interval CH 1 Quality amt Frame rate Bitrate limit GOV length OK Cancel ays the mal Image setting Click Imaging Set to adjust image brightness saturation contrast sharpness and backlight compensation mode S ONVIF Device List 4 EVC 20EVC E271 h General Identification Time Set Maintenance Network Set User Set NTV Live video Video Set Profiles Preview P 16 43 12 X Imaging Set Main Stream O so Color saturation 50 GmmT 50 GmFmT 50 OK Description This function displays the main stream of image settings and image settings can o
59. se the tester as a Server It will display its IP address at the top of the screen S77 Wl a 9 44 28 R 9 5 0 6 0 sec 9 85 MBytes 82 7 Mbits sec 9 6 0 7 0 sec 10 2 MBytes 85 3 Mbits sec 9 7 0 8 0 sec 10 1 MBytes 85 1 Mbits sec 9 8 0 9 0 sec 10 2 MBytes 85 3 Mbits sec 9 9 0 10 0 sec 9 95 MBytes 83 4 Mbits sec 9 0 0 10 0 sec 97 9 MBytes 82 0 Mbits sec 2 Start send packet test o Network test Service IP 192 168 0 232 Using the other IP tester and type in the Server s IP address at the top right corner of the screen This app is used to send packets for network speed testing Click the Start button to send the packets and start testing WF 9 44 53 X 192 168 0 18 9 5 0 6 0 sec 9 85 MBytes 82 7 Mbits sec a Network test Service IP 192 168 0 232 7 5 0 6 0 sec 11 0 MBytes 92 3 Mbits sec 9 6 0 7 0 sec 10 2 MBytes 85 3 Mbits sec 9 7 0 8 0 sec 10 1 MBytes 85 1 Mbits sec 9 8 0 9 0 sec 10 2 MBytes 85 3 Mbits sec 9 9 0 10 0 sec 9 95 MBytes 83 4 Mbits sec 9 0 0 10 0 sec 97 9 MBytes 82 0 Mbits sec 7 6 0 7 0 sec 11 1 MBytes 93 3 Mbits sec 7 7 0 8 0 sec 11 1 MBytes 93 3 Mbits sec 7 8 0 9 0 sec 11 1 MBytes 93 3 Mbits sec 7 9 0 10 0 sec 11 1 MBytes 93 3 Mbits sec 7 0 0 10 0 sec 111 MBytes 93 2 Mbits sec Network bandwidth testing can also be tested with a computer using compatible network bandwidth tes
60. signal level is 140 15IRE For PAL format the video signal level is 1000 200mV If the level is too low it will cause the image to lose quality and limit the distance it will travel over cable If the level is too high it will distort the image SYNC level Tests the amplitude of the video sync pulse to verify if the video level is correct For NTSC format the SYNC level is 40 SIRE For PAL format the SYNC level is 300 35mV If the level is too low it will cause the image to not frame out properly If the level is too high it will lead to a poor quality image COLOR BURST level Testing the color burst level will determine if the burst signal is sufficient to trigger the displays color producing circuit Burst will diminish in amplitude over longer cable runs and 300 can get fall below the threshold for the video display to show a color image For NTSC format the Chroma standard level is 40 IRE For PAL format the Chroma standard level is 280mV If the Chroma level is too low the color will not be as deep and some details of the image will become lighter If the Chroma level is too high there will be distortions on the image If the coaxial cable is too long it will reduce the chroma lev Image loop test Test video optical transmitter and receiver and video cable connect one end to the tester VIDEO OUT port and the other end connected to VIDEO IN port the signal send via VIDEO OUT port and received via VIDEO
61. ss e g IP camera Packet count Packet Size Packet time and Timeout Press Start to start pinging If the IP camera or network device is not configured properly or not plugged in it will say Destination host unreachable or have 100 packet loss If the tester connects to the device the send and receive packets will have a 0 packet loss Ping H 17 16 53 2 Native IP Er Tk Remote IP EA AGa AGr Bele mice Start PING 192 168 0 2 192 168 0 2 56 84 bytes of data 64 bytes from 192 168 0 2 icmp_seq 1 ttl 64 time 0 698 ms 64 bytes from 192 168 0 2 icmp_seq 2 ttl 64 time 0 339 ms 64 bytes from 192 168 0 2 icmp_seq 3 ttl 64 time 0 377 ms 64 bytes from 192 168 0 2 icmp_seq 4 ttl 64 time 0 317 ms 192 168 0 2 ping statistics 4 packets transmitted 4 received 0 packet loss time 3001ms Application PING testing is the most conventional network debugging tools It is used for testing if the connected IP camera or other network equipment s Ethernet port is working normally and the IP address is correct It s normal that the first data packet will be lost when test start 3 3 11 Cable test Click icon B to enter 5300 m 17 17 55 Remote kit 255 2 3 4 5 6 T 8 Cable type straight through cable Test LAN cable or telephone cable Connect LAN cable or telephone cable with the CCTV testerPRO and cable tester And then the connecting status cable type and the sequence of wire
62. t z Playback Photo Storage Manual Video Storage Auto OK Restore Cancel 3 3 1 3 4 x zoom image display and Video out when image input press to enter zoom press it again to quit Using the touch screen to control PTZ camera movement Tap left right upward or downward on the video image to move the PTZ camera in a desired direction Stretch two fingers outward or inward on the touch screen to zoom the image in or out 2 4 F 16 35 24 X No video signal input multiple x1 00 4 25W if not by touch screen to operate press the key to zoom out press the key to zoom in press upward and downward key to move the image A For analog video input as the resolution is 720 480 it is normal that the zoom in image is not clear But for network digital video input as it supports resolution up to 1280 960 the zoom in image is still very clear This is very helpful for IP camera installation 3 3 1 4 Snapshot Click the icon Snapshot when the video in to take a picture and save the current video frame in the SD card as JPEG file If the unit is set to the manual mode an Input Name pop up box will appear and you can enter a title for the snapshot If the unit is set up to automatically set file names this box will not pop up IPC Test 1920x1080 Pm 16 46 17 X 2015 04 27 10 42 21 3 3 1 5 Video record When you click the Record icon video starts recording A red recording icon
63. tatus and display on the screen Read the UTP Cable tester number on the screen Captures and analyzes the command data from controlling device also can Data monitor send hexadecimal IP address scan link scan and Ping test Quickly search the for IP camera s Network test IP address on your network Cable search Find a connected cable from a bundle of cables using audio tones optional PoE test Measures PoE switch voltage and displays pin configuration AC DC Voltage AC DC current Resistance Capacitance Data hold Digital Multi meter Relative measurement Continuity testing Testing speed 3 times optional seconds Data range 6600 6600 Optical power Calibrated Wavelength nm 850 1300 1310 1490 1550 1625nm meter Optional Power range dBm 70 10dBm Visual fault locator Test fiber s bending and breakage SM and MM fiber optional TDR cable Cable length and short circuit measurement BNC cable Coaxial cable test optional Cat5 6 telephone cable 392 Tl External power DC 5V 1 5A supply Auto off 1 30 mins Working 10 C 50 C Temperature Working Humidity 30 90 Dimension Weight 194mm x 112mm x 48mm 540g Note signs means optional function modules 4 2 Multi meter specifications Counts 6600 6600 Conversion rate 3times s Current modes for clamp meter with ZERO function Isolation the Multi meter connector must be isolated with the other connector DC
64. test Diode measurements Capacitance measurement Auto Manual measuring range switching relative value measurement and locking It is easy operation and professionally accurate mi To 2 3 27 Visual fault locator Optional Visual Fault Locator with 650nm wavelength can emit red laser sources to test multi mode and single mode fiber s bending and breakage and Continuous light emitting and 1HZ 2Hz modulating light output It is indispensable tool in fiber project constructing fiber net work maintaining optical component manufacture and research 2 3 28 Optical Power Meter Optional The IP camera tester adopts the most advanced handheld instrument specific integrated chip achieve ultra low power operation with the 3 5 TFT LCD High definition screen display five wavelength calibration points 1625nm 1550nm 1490nm 1310nm 1300nm 850nm Linear or nonlinear optical power display it can measure the optical power value and also be used for Relative measurement of optical fiber link loss It is necessary tool for fibre optic communication cable television system and security system maintenance 2 3 29 LED Flashlight Press the LED On Off button to use the LED flashlight 2 3 30 Screen image rotates 180 degrees You can manually rotate the display 180 degrees using the settings 2 3 31 TDR cable length and short circuit measurement Optional TDR cable testing accurately measure BNC cable network cable controls ca
65. then login the camera Password s Show Y Remember _ Non verification Login Login Out Click device list of the tester s screen left will shows the camera information and setting Such as Device information Time setting Maintenance Network setting User management Live video Image setting etc Some functions must camera s setting open to operate OL a 16 39 51 X Device List 4 EVC 20EVC E271 Location country chi ONVIF Serial 4 192 168 0 201 80 Add Refres h Live Video Click Live Video to view the live video feed from the IP camera To make the image full screen double tap on the video Stretch two fingers outward or inward on the touch screen to zoom the image in or out If you want to zoom in or out pls press the key tele and wide 347 ONVIF Main Stre Device List 4 General EVC 20EVC E271 Serial 192 168 0 101 80 Time Set identification Maintenance Network Set 192 168 0 188 Location country chi User Set General NTV Serial 3 192 168 0 190 Location country chi Video Set ONVIF Serial 4 192 168 0 201 80 Add Refres h Imaging Set Profiles Preview ONVIF PTZ control Tap the image in the direction you want the PTZ camera to move Tap the left side of the image to move left right to go right up to go up and down to go down Compatible IP PTZ cameras will rotate accordingly PTZ rotation direction i
66. ting software Install network bandwidth testing software on a computer as atest Client or Server with testera mutual testing If computer as the server the computer IP address is 192 168 0 89 573 01 C Network Tester E prj y cez Server English C Client Start Test Tester as Client tester s IP address is 192 168 0 230 The Server and the Client are at the same network segment but with different IP address Input Server s IP address 192 168 0 89 in the tester and click Start to test network bandwidth TW Network test a 9 44 53 X Stop 192 168 0 16 Service IP 192 168 0 232 9 5 0 6 0 sec 9 85 MBytes 82 7 Mbits sec 9 6 0 7 0 sec 10 2 MBytes 85 3 Mbits sec 9 7 0 8 0 sec 10 1 MBytes 85 1 Mbits sec 9 8 0 9 0 sec 10 2 MBytes 85 3 Mbits sec 9 9 0 10 0 sec 9 95 MBytes 83 4 Mbits sec 9 0 0 10 0 sec 97 9 MBytes 82 0 Mbits sec 7 5 0 6 0 sec 11 0 MBytes 92 3 Mbits sec 7 6 0 7 0 sec 11 1 MBytes 93 3 Mbits sec 7 7 0 8 0 sec 11 1 MBytes 93 3 Mbits sec 7 8 0 9 0 sec 11 1 MBytes 93 3 Mbits sec 7 9 0 10 0 sec 11 1 MBytes 93 3 Mbits sec 7 0 0 10 0 sec 111 MBytes 93 2 Mbits sec Or tester as a Server computer as test Client select Client input tester s IP address to test 2579 Tl Rhames C RAR Server a APNiclient when tester as Server shows results MJNetwork test a w 9 44
67. ut dome camera rotates correspondingly PTZ rotation direction is displayed on the image s left upper corner By two fingers move outward and inward on the touch screen to zoom in and out the image When the image is enlarged click left right upward and downward the image to view every detail PTZ control by press key button Press arrow keys to control CIO lt i gt A f to control the PTZ direction of rotation Press the key to switch on or turn off the aperture Press the key Gx adjust the focus manually Press the key manually adjust the zoom 1 2 RS485 RS232 control Port RS48S AS232 Protocols Minking 01 Address Baud Rate Honzontal Speed Vertical Speed Set Position Call Position fi OK Cancel SAT Operation details Pls refer to 3 3 1 PTZ 1 PTZ control parameters setting 2 Coaxial camera menu setting Click Coaxial control and select camera menu can open the dome menu 19702 1080P 30ips FP BURIALS Port Coaxitron Address Horizo Vertica Set Position See Call Position gt 4 Cancel Input calling dome camera menu address code click confirm then press key button eor click screen icon CJ ef Port Coaxiiron Address Cancel Press arrow keys to set BASIL 19702 1080P 30ips 6 30 15 X 3 Snapshot record Photo viwer and video play back Pls refer to 3 3 1 PTZ 1 PTZ control parameters setting
68. work device a 00 y 2 3 19 Access the dynamic IP address The IP tester can directly access a dynamic IP address assigned from its DHCP server and use it as the tester s IP address No need to set a IP address manually 2 3 20 Multiple network IP Cameras Test Supports Multi segmented Static IP address setting which can simultaneously test different segments of IP network Cameras 2 3 21 Network bandwidth testing The network bandwidth test needs two IP tester meters to test bandwidth one as a transmitter the other as a receiver 2 3 22 IP address scan The IP address scan can quickly search for connected IP cameras or another network device IP address 2 3 23 PING Test PING is the most conventional network debugging tool it is used for testing if the connected IP camera or other network equipment is working normally and the IP address is correct 2 3 24 Port Finder The tester will send signals to make the connected PoE port flicker at a set frequency This will enable the installer to easily and quickly find the connected port for an Ethernet cable 2 3 25 PoE Test Test the PoE voltage from a PoE switch The unit will clearly display the voltage for each wire in an Ethernet cable 2 3 26 Digital Multi meter Optional The tester built in highly stable and reliable 33 4 digit 6600 digital multi meter It is used for the DC and AC voltage measurement AC and DC current measurement Resistance measurement Continuity

Download Pdf Manuals

image

Related Search

Related Contents

Manual - D and S Vending Inc.  Carrera Formula Engines  TIME CODE REPAIR KIT - Brainstorm Electronics  USB-Blaster Cable User Guide    pistes pédagogiques - Festival d`Aix-en  sistema de monitoreo y alerta fitosanitari  5.1 Multimedia Home Theater System User Manual  Manuel d`instructions et schéma explicatif  User Manual BAS-3000BC Series  

Copyright © All rights reserved.
Failed to retrieve file