GT14-RS2T4-9P RS-232/485 Signal Conversion Adapter User`s

image

Contents

1. HIMEJI JAPAN
2. may cause hazardous conditions resulting in medium or slight personal injury or physical damage Z CAUTION Depending on circumstances procedures indicated by CAUTION may also be linked to serious results In any case it is important to follow the directions for usage MOUNTING PRECAUTIONS CAUTION e Use the RS 232 485 signal conversion adapter in the environment that satisfies the general specifications described in this manual Not doing so can cause an electric shock fire malfunction or product damage or deterioration OPERATION PRECAUTIONS CAUTION e Power OFF the GOT and then connect securely the RS 232 485 signal conversion adapter to the specified connector in the GOT Poor connection may cause malfunction e Remove static electricity charged in the human body before handling the RS 232 485 signal conversion adapter Static electricity may damage the stored data and elements DISPOSAL PRECAUTIONS CAUTION e When disposing of the product handle it as industrial waste Related Manuals The following manuals are relevant to this product When these loose manuals are required please consult with our local distributor Manual Number Model Code Manual name Contents Describes the GT14 hardware relevant content such as part names external dimensions mounting wiring specifications and introduction to option devices sold separately JY997D44801 GT14 User s Manual 09R823 GOT
3. 1000 Series Connection Manual Describes system configurations of the SH 080868ENG connection method applicable to GOT1000 ae at GT 1D7MC2 series and cable creation method Works3 sold separately GOT1000 Series Connection Manual Non Mitsubishi Products 1 for GT Works3 Describes system configurations of the connection method applicable to GOT1000 series and cable creation method sold separately SH 080869ENG 1D7MC3 GOT1000 Series Connection Manual Non Mitsubishi Products 2 for GT Works3 Describes system configurations of the connection method applicable to GOT1000 series and cable creation method sold separately SH 080870ENG 1D7MC4 GOT1000 Series Connection Manual Microcomputer Describes system configurations of the SH 080871ENG connection method applicable to GOT1000 MODBUS Products 1D7MC5 series and cable creation method Peripherals for GT sold separately Works3 1 Overview The GT14 RS2T4 9P RS 232 485 signal conversion adapter hereinafter referred to as RS 232 485 signal conversion adapter converts the RS 232 communication interface of the GOT into the RS 485 communication interface Applicable GOT units are shown below GOT GT1455 QTBDE GT1450 QLBDE GT1455 QTBD GT1450 QLBD 2 Part Names and External Dimensions 48 1 89 Unit mm inch Contents 5 pin Fixed type D Sub 9 pin female M3 tapping screws accessory e 1Pair 2Pair
4. 2 5 Phoenix Contact Inc e Refer to the table below for applicable wire sizes Electrical wire size No of wire per terminal Ferrules with Stranded wire plastic sleeve j 0 14 to 1 5mm 0 14 to 1 0mm 0 25 to 0 5 mm AWG26 to AWG16 AWG26 to AWG16 AWG24 to AWG20 5 0 14 to 0 5mm 0 14 to 0 2mm AWG26 to AWG20 AWG26 to AWG24 7 Installation 1 Turn off the GOT power 2 Connect the RS 232 485 signal conversion adapter to the RS 232 interface on the GOT 3 Fix the RS 232 485 signal conversion adapter to the GOT using the provided M3 tapping screws Tightening torque 0 3 to 0 6 Nem 8 Cautions on use of RS 232 485 signal conversion adapter e When using the RS 232 485 signal conversion adapter select Communication setting gt 5V power supply gt YES on the utility screen in the GT14 main unit For details refer to the following GT14 User s Manual 8 2 Utility Function List e The GT14 main unit whose hardware version is B or later supports the setting whether or not 5V power is supplied In the hardware version A the setting operation about 5V power supply is invalid because 5V power is always supplied e When using the RS 232 485 signal conversion adapter make sure that the core OS version is V05 28 00AP or later and the standard monitor OS version is V05 28 00 or later in the GT14 main unit For details refer to the following GT14 User s Manual 12 1 2 OS version c
5. JY997D44401C A _ JAPANESE B ENGLISH Side B a MITSUBISHI Changes for the Better GT14 RS2T4 9P RS 232 485 Signal Conversion Adapter User s Manual Manual Number JY997D44401 GOTiooo Jan 2012 This manual describes the part names external dimensions and specifications of the product Before use read this manual and manuals of relevant products fully to acquire proficiency in handling and operating the product Make sure to learn all the product information safety information and precautions And store this manual in a safe place so that you can take it out and read it whenever necessary Always forward it to the end user Registration The company name and the product name to be described in this manual are the registered trademarks or trademarks of each company Effective Jan 2012 Specifications are subject to change without notice 2011 Mitsubishi Electric Corporation Safety Precaution Read these precautions before using Before using this product please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly The precautions given in this manual are concerned with this product In this manual the safety precautions are ranked as gt DANGER and A CAUTION Indicates that incorrect handling may cause hazardous lt gt DANGER conditions resulting in death or severe injury Indicates that incorrect handling
6. e Terminating resistor 1109 OPEN 330Q At factory shipment 2Pair Terminating resistor 330Q 1 pair 2pair Terminating resistor setting switch A 3 Specifications 3 1 General Specifications Other specifications are the same as the GT14 main unit Item Specifications Operating ambient 0 to 55 C temperature Storage ambient 20 to 60 C temperature Operating Storage i ambient humidity 10 to 90 RH non condensing Must be free of lamp black corrosive gas flammable gas or excessive amount of electro conductive dust particles and must not be exposed to direct sunlight during operation and storage Operating atmosphere Power consumption 0 5W or less 100mA 5VDC supplied from the GOT 4 Pin assignment Signal name SG SDB SDA RDB RDA Setting item 6 OFF 1pair 2pair OFF OFF Terminating resistor ene OFF e Set 1 pair or 2 pairs using the switches Nos 1 and 2 and set the terminating resistor value using the switches Nos 3 to 6 e Do not manipulate the setting switches while power is supplied to the RS 232 485 signal conversion adapter lt Setting example gt Terminating Switch No Format resistor 5 OFF pair OFF OFF 2pair OFF 6 Wiring e For the detail refer to GOT1000 Series Connection Manual Cable jacket to remove 5mm 0 19 Tightening torque 0 22 to 0 25 Nem Recommended Tool Screwdriver SZS 0 4x
7. onfirmation This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi opportunity loss or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life e Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi Electric e This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system a a MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN HIMEJI WORKS 840 CHIYODA CHO