Home

End user manual series 2000 & 3000 Rev 6 End User Manual ser

image

Contents

1. The Red Armed LED is on when the system is armed Siren 1 poi J Status 3 The Shunt LED Dela 1 Delete 4 Chime 5 TelephoneO indicates that a zone Panic Button Test 7 Program 8 Reset 9 1 bypassed shunt 0 Blinking h means that the system time is not set hold down key 1 key then 0 three LEDs are blinking enter time in 24 hours format Hold down functions To hold down function access hold down the key for approximately 2 seconds Hold down function is confirmed by a prolonged beep Refer to hold down list 1 Siren Test 4 Delay Delete 8 Code Programming 2 Display Bypassed 5 Activate Chime 9 Delete Last key Press Zones 6 Telephone 0 Display Alarm History 3 Display Troubled Programming and Panic Zones 7 Zone Test and Display and Setting of System Time Hold down 0 key and then hold down 1 three LEDs are blinking wait for the time to be displayed in 4 digits format To set new time hold down key 0 and then hold down 1 Do not wait for time display enter the new time in 24 hours format The local clock time is not stored in the system memory clock must be adjusted after power up After powering up the system time is reset to 00 00 h will be displayed to remind user to set time h
2. 000 Three led lights Flashing In Disarmed mode rapid blinking indicates AC power failure AC power failure event is displayed in Events History as three lines In Armed mode rapid blinking indicates system restored after AC Power Failure mode During the programming of the Follow me telephone number three flashing led lights indicate that system is expecting a new telephone number 0000 Four led lights Flashing Press and hold down key 8 the system is waiting for code entry System with bypass via code Same LED indication when code is expected for Bypass via code Setting New Code with AV 701 LED keypad Hold down key While four led lights are blinking enter the master code default 1234 If code is valid the four led lights will stop blinking and u will be displayed The two Left Most LEDs blink to indicate that the system is waiting for a new user code index user to 8 to be entered 5 Enter the code index 1 for code No 1 2 for code No 2 etc User index will be displayed for 2 seconds until further digits are entered eliminate confusing of index number and code 6 The two right most LEDs blink to indicate that the system is waiting for a new code 1 to 6 digits to be entered If user code is not entered the code is voided 7 Enter the new code U is displayed for confirmation 8 Wait for u small u To quit code setting hold down 9 Bb 0 MN 13 pote
3. L Your security system Iuide y f JOUL EasyLoader Series 2000 and 3000 JUL f as VLD systems ltd Table of Contents Table or Contents ii caia 1 Table 0f Contents osas mr tdt 2 A A claus Sau Segue en oa ous tae Seen eae eee ee 3 TPPFOGUCTION EE act a E E es neste 4 SAFETY AND MAINTENANCE INSTRUCTIONS csccecsseceeseeceseecsecceessecesseecsseeessseceeseeensees 4 GLOSSARY araar lada 4 Basic Operations isnan taps ea E E A A ata ee a ts 8 ARMING YOUR SYSTEM creerii E e ERA EEOAE SEEE eiii 8 DISARMING IE EE E e 8 AMBUSH DISARMING ica ie Vaanin EAAS S aaa 8 ZONE BYPASSING acire neniet a aaa n i e a ee i 9 HOW TO BYPASS ZONES vei E ooo ceed E E E E 9 ARMING OI 9 REMOTE ARMING VIA REMOTE KEY OR DTMF cccscssessscecessseeeceessececessneaeeeeeeaaees 10 AV 701 AV 702 Keypads LED a 12 TEDIINDICATOR Sa EA EATA TA A EAT is 13 SETTING NEW CODE WITH AV 701 LED KEYPAD ccoooccccconocnnononnnncnonnnnncnonnnnnnnnncnnnnnnoss 13 KEYPAD DISPISA REEE EAE AAT A EE co AT 14 DELETE A USER CODE mirdi aoas a lada A sede Ne 15 SETTING THE FOLLOW ME TELEPHONE NUMBER cccoooccncconononononononnnonnnnnnconnnnnncnnnnnnnnnnoss 15 PROGRAMMING TELEPHONE NUMBERS ooccccoconcccononnnnnononononnnononccnnnnnnccnnnnnncnnnn nn nc cnn nnnos 15 SOUNDER taaan veh cele ida Pek Aa a ERA AER atea 15 AV 707 AV 706 AV 705 Keypads LCD fits PRO Dublo panels 16 INTRODUCTION anaconda a a E
4. Sign is displayed and arming denied system can not be Armed with an open instant or 24H zone The system is not responding keys do not respond 1 Hold down 9 key until you hear a beep then enter arming code 2 Program new arming code 3 If you forgot your Arming code call your installer 1 Hold down 9 key until you hear the confirmation beep Enter arming code carefully Do not be confused by Siren noise 2 System was armed using the Instant Arming key key 5 but code was changed You can ask your installer to cancel this feature To disable zone s bypass Arm and disarm the system the Yellow indicator light turn off Hold down 3 key the zone s in trouble will be displayed Check the cause an open window movement detected by detector or else 1 Press 0 key Bypass and then the zone number where alarm was triggered The yellow indicator should light in confirmation 2 A delayed zone may be troubled An open delayed zone will cause the green indicator to blink upon exit entry You may have a general power failure Check your premises fuse box Warning If Green indicator is still OFF your system is operating on temporary power supplied by the Battery 22 PROBLEM INDICATION REMEDY Buzzer is activated Door at delayed zone Keys 5 or 7 have been pressed activating for no apparent entrance is open or the door Chime or the Fault Find function reason
5. User w user followed by user number when events log is displayed and system is in user code programming mode Arming Denied Displayed upon Arming attempt with non delayed or instant zones in trouble Three lines AC Failure Displayed after AC failure in history display at the AV event 701 keypad indicating the power fail event 14 Delete a User Code 1 Hold down key 2 While four led lights are blinking enter code No 1 default 1234 3 If code is valid four led lights will stop blinking and u will be displayed 4 The two left most LEDs blink to indicate that the system is waiting for a new user code index user 1 to 8 to be entered 9 Enter the code index you want to delete 1 for code No 1 2 for code No 2 etc 6 The two right most led lights blink to indicate that the system is waiting for a new code 7 Hold down 9 key to quit code setting If user code is not entered the code is voided A short beep confirms te that the code has been deleted No Setting the Follow Me Telephone Number The Follow Me feature is applicable only with the dialer in alarm Follow Me 1 number is dialed first if the communicator communicator dials to central station is not selected 1 Hold down 6 key twice wait for the blinking of the three led lights 2 Enter Telephone Number maximum 16 digits and 4 pauses and wait until all led lights stop blinking The Follow Me number
6. E display Delayed Zone triggering 3 Long beeps Exit delay starting if programmed Warning beeps until the delay is over Completion of Arm Disarm programming code One long confirmation beep Programming Telephone numbers Two confirmation beeps Completion of address programming Two confirmation beeps Pressing Code 7 for driving door opening Seven confirmation beeps System Arming with Instant or 24 hour troubled zone Five warning beeps troubled zone Feature programming Two confirmation beeps Follow Me number programming Two confirmation beeps During alarm requires programming Intermittent beep until alarm reset AV 707 AV 706 AV 705 Keypads LcD fits PRO amp Dublo panels Introduction The AV 707 EasyKey is the future generation keypad with the New Look shape fully customized microprocessor based remote station multitasking functions with 32 Keypad ID s AV 705 706 provide similar functions For more details refer to the AV 707 706 manual The AV 705 is an economical keypad its shape similar to the AV 707 and supplied without the LCD display The AV 707B contains three extra keys used for different emergency alarms fast and convenience 3 home modes AV 707B is available in Metal Gold or Silver color The AV 707 706 and 705 fits only PRO and Dublo type control panels 16 After power failure Set P
7. zone a three lines sign will be displayed indicating that the system is disarmed warning about an open troubled zone Instant Arming The Instant Arming feature allows you to press 5 key to arm the system This command is designed to allow user to arm the system without needing a full user code Note The instant arming is not recommended This will allow easy 0 arming by someone who is not a regular user 0 Auto Arming This feature provides setting of the desired system arming time when the regular user is away Auto Arming is useful for shops and sites requiring long exit delay Enter to user programming mode hold down 8 key then enter your master code three led lights will blink Hold down 8 A is displayed Enter the time in 24 hours format To display hold down 8 and wait To disable Automatic Arming program press 0000 After Automatic Arming is programmed the system time can be set only via User Programming Mode Enter User Programming Mode hold down 8 and 1234 hold down 1 t is displayed and type hour and minutes Hold down 1 and wait for the time to be displayed Holding down 0 1 keys to program the time is possible only if the Automatic Arming is disabled otherwise an Error warning is displayed Automatic Arming will not operate if the system time has not been set blinking h Automatic Arming will not operate if the control panel is already armed Automatic Arm
8. there has been Arm and disarm the system detection of Hold down 9 key to reset Day Zone or movement at an Tamper alarm exit entry zone Day or Tamper zone was activated Entry at protected A warning signalis Disarm system immediately upon entry at zone activates mini heard before the zone If delay time is too short call your sounder at keypad siren is triggered installer to reprogram delay time L is displayed Battery is low Call your installer immediately faulty or dead C is displayed Telephone line Call your installer immediately Check your blinking disconnected or dead telephone line or the systems failed to contact central station Siren was triggered 1 Faulty dialer 1 Hold down 6 key dialer test but programmed 2 Faulty phone line automatically dialed numbers will be phone numbers were or phone off the displayed test takes several minutes not dialed hook 2 If the telephone line to the alarm control 3 Mistaken report of has been disconnected reconnect it alarm 3 Malfunction of the alarm system call your installer H is displayed A panic alarm was Arm and disarm system to abort alarm and h is blinking activated Take H display emergency Set system time by holding down 0 key measures Blinking then 1 key h set the time Yellow indicator Automatic Bypass Before arming make sure all entry exit lights upon arming has been doors prot
9. to display the last alarm sequence New alarm will erase the old events De and Detailed Events History requires programming Hold down 0 and again hold down 0 to display up to 99 events like System opening and closing by user number opening or closing time zone caused alarm and AC failure Your PRO panel stores up to 250 events displayed by the EasyLoad program the keypad display 99 events only By holding down key twice three LEDs start blinking indicating a special operation mode The events are displayed from the most recent events to the oldest ones 3 and Display Last 2 Users Hold down 0 and then hold down 5 to display user number and System opening or closing time o is displayed for Opening Disarming c is displayed for Closing Arming 19 Events Display Events are displayed as following XX Event number from 01 to 99 then HH_MM Hour and Minutes Event Time Event alarm or opening closing Translate the display as following u user number 1 to 8 o or C opening or closing Zone causing alarm will blink twice X Tamper alarm from zone causing the alarm X H Panic Alarm Note three lines indicate power failure An AC failure event will be displayed during history events For detailed log events ask your installer to download the log events via EasyLoad software Trouble Conditions The system constantly monitors itself to ensure
10. Keypad display The 7 segments also called LED keypad display provides visual readout of the system status The display indicates zones in alarm troubled zones bypassed zones and displays the following confirmation letters Display Description Function Up amp Download Modem Answer Now function selected Confirms hold down 6 key then hold down 1 key A also displayed upon Auto Arming programming Communication Displayed at dialer tests and upon holding down 6 key Communication C flashing in display indicates telephone line trouble Chime Confirms Chime mode via 5 key Closing When events log is displayed Indicates Arming followed by user number Delay Delete Confirms Delay Delete Upon holding down 4 key Dial Delay When programming telephone number that requires an inter digit delay Pause during dialing Delay duration is 2 seconds Error Indicates programming and operation error Home Indicates entering of Home Mode Group Bypass Hour Displayed after power up to remind user to set the system time h will be removed after time setting using keys 0 and 1 Hold Up Upon Panic triggering from Keypad Opening Indicates system opening Disarming Followed by user number when events log is displayed Low Battery Indicates Low Battery Call your installer Program System is in programming mode Tamper Indicates zone s Tamper alarm Update Confirms programming updating
11. all or calls the user It indicates that the panel expects a valid user code 2 User code accepted 3 Error Will be sounded in the following cases Incorrect user code command not defined valid incorrect input trying to bypass an undefined zone command could be not carried on on line time out or call ends 4 Confirmation Will confirm that the requested action has been carried out 5 Armed Control panel is Armed 6 Disarmed Control panel is Disarmed 7 Alarm On Control panel is in Alarm position This warning will be sounded from time to time during idle periods Remote DTMF function example For example let s assume that your kid arrived home and he cannot disarm the alarm panel Call your alarm telephone number tell the kid not to pick up the phone After a few rings your system answers A greeting tune is heard Enter your user code 123 4 Confirmation tune is heard If alarm is on siren tune is heard Press 2 and wait for the confirmation tune To re check the system status press 7 and wait for the system status tune In case the system is still on re enter 2 or try to enter your user code then 2 11 AV 701 AV 702 Keypads LED type AV 702 keypad contains identical keys and LED structure to AV 701 The Status LED is on I AV GAD EASYLOADER AV 701 when all the zones A are closed ZONE ARMED STATUS SHUNT FIRE DISPLAY
12. anel Time is displayed To set time hold down 0 key then Hold down 1 enter time in 24H format and press To set the date hold down 0 key then hold down 2 enter date in day month year format and The AV 707 keys and Hold Down functions are identical to the AV 701 functions you can speed up the function by pressing key the ENTER key The sounder and Led lights and indications are the same as described for the AV 701 s The mx key in LCD keypads is mostly used as an ENTER key pote typed at the end of a command LCD display The LCD display helps understanding the system status and zone locations by reading in plain text the system messages zone description time and other indications The first row displays system announcements like System Disarmed Alarm Low Battery etc second row displays the zones status Each sign represents a zone If a zone is open the zone s number like 123 567 will replace the If a zone is bypassed a appears instead The control panel time is displayed in the five rightmost positions The LCD displays often the installer LOGO the logo is editable For displaying zone description hold down 3 key twice To save power the LCD and keys backlight turns OFF after 60 seconds of no typing activity it turns ON again when an alarm occurs System Message 7D System isarmed 3 12 00 a
13. attempts to enter an invalid code the keypad locked itself for 30 seconds 20 pote Delays Delete Delay Key 4 gt DELAY DELETE INSTANT PROTECTION Cancels the Entry Delay in zones selected as Delayed zones All zones become Instant This feature is optional when Home Mode set and all users are in Hold down 4 key d is displayed in confirmation Instant Protection becomes effective only if System is armed within 20 seconds following hold down of 4 key Key 5 gt DOOR CHIME The Door Chime initiates the keypad to beep whenever a zone is activated Door Chime operates on Chime programmed zones Hold down key 5 enables and disables the function Chime mode is confirmed by c displayed on keypad and L 4 gt LOCAL BUZZER ON and OFF Holding down keys 0 and simultaneously turn on and off the buzzer in each LCD keypad This function works in disarmed mode Testing Your System It is recommended to test your system daily or weekly Perform system tests in the off peak hours such as early morning or late evening Call to inform your monitoring station that you are testing your system Siren and Battery Test Hold down key 1 This command will generate a siren sound for 2 3 seconds Turn off your main AC verify that LEDs are blinking to indicate power failure test siren again to make sure your battery can drive the siren during power failure Arm and Disarm the system main AC is stil
14. der The sounder in Keypad simplifies alarm recognition by producing different amounts and sound patterns to identify various events The sounder also functions as key press confirmation Siren The siren generates noise and light indication when strobe included in order to indicate burglary fire or other emergency cases It s recommended to install a siren indoor and outdoor of the protected site SMS Message Short Message Service for series 3000 SMS is the text communication service component of series 3000 alarm panels in case of alarm or other selected events the alarm system sends you the same message displayed on your LCD keypad to your SMS enabled phone The transmitted events are programmable User Codes One master and seven codes are available to allow users to arm and disarm the system and to bypass zones Keep the code confidential to ensure maximum system security Zone also called Area An area protected by a security device For example a room protected by a motion detector as Zone number 1 while a door protected by a magnetic contact as Zone number 3 Your installer will inform you which zones have been set up on your system The AV 701 contains a zone index list The AV 707 LCD keypad displays the zone description like Garage Jimmy s Room etc Basic Operations Arming Your System Before arming your system close all protected doors windows and do not move around areas protected by motion
15. detectors When all protective zones are closed the Green Status LED stops blinking Exit door and other delayed zone may stay open upon exit the protected areas To arm the system enter your code At each digit entry the keypad sounder will beep When the code has been entered the Armed LED will light If an incorrect user code is entered the keypad will sound a single long tone To correct the mistake press 9 and enter the code again When the Armed light is on leave the premises through the designated entry exit door before the exit delay expires At the end of the exit delay all lights on the keypad will be shut off except for the Red Armed light Your system is now armed The factory setting for the exit delay is 30 seconds your installer may change this time to suit your needs Refer to the Arming Options section of this manual for information on other arming functions Disarming Enter the premises through the designated entry exit door The keypad will sound a constant tone to indicate that the system must be disarmed Enter your code at keypad if an error made while entering the code press 9 and enter the code again After six wrong entries the keypad locks itself for 30 seconds keys do not respond during this period When a correct code is entered the armed light shuts OFF and the sounder is silent Y our system is now disarmed Enter your code before the entry delay expires to prevent alarm The factory
16. e Siren Times Silent Zones Notes EasyLoader Series Alarm Control Panels End User Operating Manual 5 For version 2 18 up to 3 06 Congratulations for purchasing this state of the art computerized security panel You have made a wise investment in the future safety of your home or business premises with this high technology security system however it s still as EASY as 1 2 3 If you have one of the new series 3000 alarm refer for details regards the SMS in the system technical manual Introduction Review this manual carefully before operating your security system Y our installer should instruct users how to operate the system and about it s various features Complete the System Configuration page and store this manual in a safe place for future references Safety and Maintenance Instructions Y our security system cannot prevent burglaries emergency cases or damage to your property It is only intended to alert emergencies To keep your system efficient as intended it is recommended to test the system daily upon arming and weekly testing the siren and detection devices Read the Testing your System section If your system does not function properly contact your installer Keep the keypad dry clean the keypad with dry cloth Never disconnect the main AC to your system Glossary Your security system has been designed to offer the latest security features with simple and easy operation Described here are
17. ected by system are closed and all of system without programmed Can detectors are off Arm the system and call bypassing pressing also occur if 0 key your installer 0 and any key is pressed twice before arming which activates zone bypass 23 WARRANTY AV GAD LIMITED WARRANTY Av Gad Systems Ltd Av Gad warrants its products to be free from production defects in components materials used and labor for the period of twelve months following the date of production Av Gad will within the mentioned period as its option repair or replace any product failing to proper operation without charge This warranty shall not apply to any equipment or any part thereof which has been repaired by others installed not properly used improperly abused altered damaged subjected to acts of God or on which the serial and data code altered or removed Av Gad will not be responsible for any dismantling or reinstallation expenses In order to exercise the warranty the product must be returned by the purchaser delivery and transportation costs prepaid and insured to Av Gad After repair or replacement Av Gad assumes the cost of returning products under warranty There are no warranties express or implied which extend beyond the description of the face hereof There is no express or implied warranty of merchantability or a warranty of fitness for particular purpose Additionally this warranty is in lieu of all other obligat
18. erecto lcd cerca bicis as 16 ECDDISPLA ec ici 17 KEY ENTRIES 4 ad a ao teca canela dad cr redes al o 17 SETTING NEW CODE amp GROUP BYPASS WITH AV 706 707 KEYPADS cccononcncncninononononons 18 SETTING FOLLOW ME TELEPHONE AT AV 706 707 ooconocococonononononanononannnonononononononononons 18 Displaying System Information tii ia ibid 19 ALARM MEMORY DISPLAY oare e AI NAE O AENA AE ATE SAER 19 EVENTS DISPLA Vi a AAS EA EE ee 20 TROUBLE CONDIT ON Sica ctra VE AE VTE TEREE E 20 Setting System Features neaei a aa a aa ias 20 CHANGING CODES hrie aaa n da little 20 DELAYS DELETE AEE E A E dad AE E AN A E E A 21 Testing Y our Systemin on u a deat ive asl E sE 21 SIRFNAND BATTERY TEST 0d a a ON EE AI ds 21 DETECTION DEVICES TEST iaa aa 21 TESTING YOUR CENTRAL STATION CS cccscecssessseesseesseeseeceeceaeceaecnseeeseeseeeeeeeeneeeaeenaes 22 ME OUTS OLS Fe 55 IEEE on caos 22 AV GAD LIMITED WARRANTY seai aaa a a aa a 24 Item 4716 A4BKE Rev 6 All Rights Reserved to AV GAD SYSTEMS LTD Tel Aviv Israel POB 49 080 Tel Aviv 61 104 Israel W7 END_2000_Rev 6 large May 2011 System Configuration Zone Index Zone Description Type Zone Description Type 1 9 2 10 3 11 4 12 5 13 6 14 7 15 8 16 Installation Data Installer CS Information Programmed Telephones Phone Phone Mobile Account No Installation date Contact Person Zone s at Home Mod
19. hortening for the most common dialing protocol Dual Tone Modulated Frequency Av Gad panels use the DTMF for dialing and in latest alarm panels also used for remote commands like Arming Disarming Zone Bypass and some more functions Digital Display Keypad enhanced LED 7 segments display Provides alphanumerical readout of zone status and messages Entry Delay The Entry Delay is the period allowed for someone to enter the premises and disarm the system Entry Exit Zone The entry exit door or zones are designated by your installer to be used for entering and leaving the premises when the system is armed Exit Delay The Exit Delay is the period allowed for users to leave the premises after arming the system Fire Zone A zone programmed for connection of fire or smoke detector Alarm heard in both Armed and Disarmed modes and Fire LED is activated The siren sound is different from the 24H zone or burglary alarm it depends on the siren type used To reset Fire alarm hold down 9 key and your code Follow Me Programmable Telephone Number Follow Me it s a dialer feature The desired Follow Me Telephone number is programmed by the user prior to arming as necessary to follow the user destination Follower Zone also called conditioned Zone Follower Zone reacts instantly upon detection without previous triggering of Delayed zone Exit delay applies to Follower zones and Delayed zones Hold down Functions Holdi
20. ing will operate even if the control panel is currently in ALARM When the Automatic Arming programmed time arrives the system starts at a 30 seconds countdown An A is intermittently displayed and beep sounds at keypad During the countdown period the Automatic Arming can be aborted by entering a valid user code not code No 7 if used to open a door Remote Arming via Remote Key or DTMF The Remote Arming allows you to use a remote key switch or wireless Av Gad set AVS22 tiny transmitter to arm the system This command is designed to arm the system without a code or for convenient arming from your car Remote functions with DTMF D suffix D for DTMF alarm panels type provides certain remote functions The DTMF remote control functions gt Check the control panel status Armed Disarm Alarm in progress gt Inform the zone number that caused alarm beeping the zone number on the phone gt Arm and disarm the control panel gt Bypass zones or clear all bypassed zones gt Stop the dialer report during alarm gt Momentary activate Al alarm output for three seconds Verify with installer that the system is programmed to answer income calls To get on line dial to the control panel The control panel will answer the call after the number of rings as programmed When answering the call control panel sends a greeting tune sound enter your user code within 5 seconds 1234 and confirm pressing the ke
21. ions or liabilities on the part of Av Gad Any action for breach of warranty including but not limited to any implied warranty of merchantability must be brought within three months following the end of the warranty period In no case shall Av Gad be liable to anyone for any consequential or incidental damages for breach of this or any other warranty express or implied even if the loss or damage is caused by the seller s own negligence or fault Av Gad is not an insurer of either the property or safety of the user s employees family or 3rd part and limits its liability for any loss or damage including incidental or consequential damages to Av Gad original selling price of the product regardless of the cause of such loss or damage pot Av Gad recommends testing the entire system weekly Refer to Testing Your System section for further details WWW av gad com 24
22. is now programmed 3 To delete Follow Me number access Follow Me programming mode as described in paragraph 1 but do not enter any number Programming Telephone Numbers 1 Hold down key 8 2 While four led lights are blinking enter the master code default 1234 3 If code is valid four led lights will stop blinking and u will be displayed 4 The two Left Most LEDs blink to indicate that the system is waiting hold down keys 6 1 for first number 6 2 6 4 followed by the telephone number U is displayed for confirmation If number not entered the system will display the telephone number To erase a number hold down continuity 6 hold down 1 then hold down 9 to erase the first number wait for u to quit setting hold down 9 Sounder The Keypad sounder enhances the use of system operation and serves as a local alarm device requires programming Several programmable features set the sounder functionality Ask your installer for more details 15 With AV 705 706 707 LCD keypad the user is able to switch the buzzer on and off at each keypad Holding down keys 0 and simultaneously turn on and off the internal buzzer The sounder emits sounds in the following instances OPERATION SOUNDER RESPONSE Pressing of any key Short confirmation beep Hold down functions Long confirmation beep Faulty programming input Long beep
23. l off few times if L is displayed your battery is faulty call your installer Detection Devices Test Tes 7 Key 7 gt FAULT FIND e Fault Find enables testing of all detection devices e Fault Find mode can be entered only during the 15 seconds following system Disarming e Fire 24H or Panic alarm will stop Fault Find mode e Hold down 7 key confirmed by F on Keypad display e Activate each sensor Detection of zone opening is confirmed by a one second beep Three beeps indicate zone closing e Arm the system to quit Fault Find mode 21 pot Testing your Central Station CS Inform your CS that you perform testing ask them to report you if an alarm is received Arm the system move in front of a detector or open a protected door verify that the siren is activated to quit testing disarm the system poto Test your system daily Call your installer if any test fails to operate Troubleshooting PROBLEM INDICATION REMEDY System fails to Arm when code is entered at Keypad System cannot be disarmed Yellow indicator is on indication that zones have been bypassed Green indicator blinks continuously when you attempt to arm the system Three LEDs indicators are blinking indicating Power Failure Keypad entries are confirmed by beeps but system does not react Arming Disarming code is entered but Red indicator remains lit Yellow shunt indicator constantly on
24. mber 1 to 8 or 1 to 16 in AV 2016 the Shunt Bypass Yellow light is on in confirmation enter your arming code Armed Red LED goes on To remove a bypassed zone arm then disarm the system re enter the bypassed zones When you arm your system the zones you have indicated will now be bypassed When arming the system with bypassed zones it is always recommended to review the list of bypassed zones before entering your code to arm the system After bypassing the desired zones enter your code to arm the system Arming Choices Group Bypass Home Mode Arming with Home mode automatically bypasses the zones programmed as Group Bypass This feature allows you to arm the system and remain on the premises For new systems version 2 17 and later To bypass first group press 0 and hold down 1 to bypass second group press 0 and hold down 2 to bypass both groups press 0 and hold down 0 AV 707B keypads are most convenient for arming with home mode one button press for group bypass and arming At Home Mode another person would still be able to enter the premises through the entry exit door without causing an alarm requires special programming To disarm the system when the entry exit door is opened enter your user code Away Arming Close all protected doors and windows you can move in front of the delayed detector Enter your code and check if the Armed LED is on In case of arming with an open
25. ndicating that data is expected in this case the new User Code 12345667 12 00 Js ees Enter a one to six digits code Key 0000 corrects the input press as backspace or Hold Down key 9 reset to cancel the input Press key as ENTER for confirm The control panel will verify that the new code is not in use by other user if that happens you ll be notified and respond by DOGO displaying the code At any time after the control panel response you can start typing a new index there is no need to wait for the announcement to disappear To erase an existing code Enter user index number 01 02 03 hold down simultaneously keys and followed by E erased will be displayed The Master code number 01 cannot be erased Type 99 followed by to exit User Programming mode Setting Follow Me Telephone at AV 706 707 To display the Follow Me telephone number hold down 6 type for faster display and the control panel will display the number or the empty announcement if there is no telephone number currently programmed To program the Follow Me telephone number Hold Down twice the 6 key The three Rightmost LEDs blink indicating that the keypad waits for input 18 On the upper display line a blinking cursor will appear type the number digits from 0 to 9 hold down for digit hold down 0 key for Pause a P will be displayed or press simultaneously amp
26. ng down keys for about 2 seconds provides additional easy to access functions Instant Arming System Instant Arming Short press on key 5 instantly arms the system Instant Zone Zone feature The system reacts instantly upon detection at a zone which has been programmed as Instant Key switch optional Located on control panel door or remote panel Used for arming disarming the system Keypad Your system contains one or more keypads The keypad is used to operate the system and display information about the system Commands are entered on the keypad by pressing one key at a time LCD Shortening for Liquid Crystal Display This type displays full texts zone locations messages etc AV 706 and AV 707 are LCD type keypads LED Shortening for Light Emitting Diode LED is a modern bulb LED visually displays the system status and confirms the functions Master Code The Master Code is a 4 to 6 digits code is used to arm and disarm the system to program your codes and to bypass zones in certain models Normally only one person should know the Master Code Your default master code is 1 2 3 4 Panic Button Two keys and on the digital keypad for alerting the central station in case of emergency Programmable Features Computerized control panel allows system tailoring to suit individual requirements Smoke Detectors Triggers alarm upon detection of smoke Smoke detector requires reset after alarm Soun
27. proper operation When a trouble condition occurs the system condition will be displayed Indication Cause To do L or Low Battery on Battery is low Call for service Four LEDs are blinking AC power failure Check the premises fuse box Call for service C or Tel Line Fail Telephone line test failed Call for service Arming fail and is Zone is troubled Bypass the zone and call displayed for service Setting System Features Changing Codes The system features eight programmable codes The first code is the Master Code and the remaining seven codes are normal arming and disarming codes Do not use 0 as the first digit in a code Do not use 5 as first digit in a code number if Instant Arming via key 5 was programmed User code shall not start with the same numbers as the installer programming code 1994 Do not use same codes or same first digit for different codes For example if code No one is 1234 programming code No 2 cannot be 1256 Key Visual Feedback Visual feedback from the keypad display upon entering of code This feature indicates the code entry progress and is most practical when the keypad buzzer is disabled at Home Group Bypass mode or if selected by programming Entry of code by user or installer is confirmed at keypad display Display segments will light up clockwise indicating the sequence of the entered digits Note After six unsuccessful
28. rmed Status shunt fire Bypassed Zone Close Zone Open Zone Time AV 707 Most of the accessible functions with the LCD Keypad are similar to those of the AV 701 seven segments keypad Key Entries Keys typed at the keypad are concealed as they are part of the User Code signs are displayed In Armed and Disarmed mode after six attempts to enter fault code the keys will not respond for 30 seconds in order to prevent code break exigency During all kinds of programming keys are displayed as they are typed some combinations are exceptional 17 Setting New Code amp Group bypass with AV 706 707 keypads To enter User Programming mode Hold Down key 8 program The three Rightmost LEDs start blinking enter the Master User Code factory default 1 23 4 followed by Enter The upper line displays User Programming the lower line is cleared and a blinking cursor appears The Leftmost two LEDs will start blinking indicating that location is expected In this case location means User Code index to be modified erased or programmed User Index means User Number 1 8 as system contain eight different user codes Enter a two digits number from 01 to 08 2 digits required After the index had been A e SYSTEM DISARMED entered the location the upper line is cleared the blinking cursor moves to the beginning of the line three Rightmost LEDs start blinking i
29. setting for the entry delay is 12 seconds your installer may change the time to suit your needs If an alarm occurs while the system is armed the Armed LED blinks Refer to Display Alarm Memory for instructions on displaying the zones in alarm Ambush Disarming If you are forced by an intruder to disarm your system the Ambush alarm can be activated Disarming the system with the Ambush code will cause the system to disarm and simultaneously send a silent ambush alarm signal to central Station This P is an optional feature For details ask your installer pot IMPORTANT If you return to the premises and find that an alarm is in progress or there are alarms in memory do not enter the premises as an intruder may be present Contact local authorities from your mobile or public phone Zone Bypassing A Bypassed zone will not cause an alarm Zones may be bypassed to allow access to part of the protected area while other zones are armed For example you could bypass the zone protecting your living room This would allow you to remain in the room while the other zones on your system are armed With the system disarmed hold down 2 key to display bypassed zones The zone number displayed represents bypassed zones Ensure that any zone displayed as bypassed is intentionally bypassed Zone bypasses are automatically cancelled when the panel is disarmed How to Bypass Zones To bypass a zone press 0 key and the zone nu
30. some terms that are used throughout this manual to explain the common terms Group Bypass In certain countries called Home mode Group Bypass allows bypass of few zones determined by the installer to be bypassed at once by entering a short keys combination prior to Arming AV 707B is most convenient keypad for simple one key press for Group Bypass and Arming 24 hour Zone A zone programmed for 24 hours protection Zone is active in both Armed and Disarmed modes When a 24 hours zone is troubled alarm will sound in both Armed and Disarmed mode Battery Standby rechargeable battery located in the control box provides emergency backup power in case of power loss Bypass Shunt a zone Allows manual removal of one or more protected zones from the system Day and Tamper Zone A zone programmed as a Day or Tamper Zone enables alarm from keypad s buzzer during daytime when system is usually disarmed The Day or Tamper zone will trigger the keypad buzzer and the zone number will flash on keypad display To reset Day Zone alarm hold down key 9 reset key During Armed mode this zone will act as burglary zone and will emit an alarm when troubled Dialer and Communicator Alarm reports directly to predetermine stations via telephone lines The dialer reports an alarm to your telephone a siren or a recorded message To report a recorded message the SVM 40 electronic module is required DTMF S
31. to erase the phone number a E will be displayed To correct the input you can use the as a backspace erasing key Group bypass home mode If you want the system to disable few zones during night time for example ask installer to define a group bypass zone s Bypass is operative only if System is armed within 60 seconds from the entry of this feature Yellow LED will flash and h Home displayed for 1 second in confirmation Commands to bypass group of zone s e 0 amp hold down key 1 Arm with group 1 bypass or 0 0 Group 1 Bypass e 0 amp hold down key 2 Arm with group 2 bypass or 0 0 0 Group 2 Bypass e 0 amp hold down key 0 Arm with group 1 2 bypass or 0 88 Group 1 2 Bypass Each command works as a toggle SET CLEAR The AV 707B with extra 3 keys keypad provides arming and group bypass by pressing than hold down one key Button A most left Selects Group Bypass No 1 if programmed so and arms the system Press key than hold down key A For AV 707 without 3 buttons press 0 and 1 Button B Selects Group Bypass No 2 if programmed so and arms the system For AV 707 without 3 buttons press 0 and 2 Button C Selects both Group 1 and Group 2 and arms the system Displaying System Information Alarm Memory Display Alarms generated when the system is armed are recorded in the system s memory Press key 0 to display the zones in alarm l Concise Alarm History Events Log Hold down 0
32. will disappear after the new time is set Shunt and Display and Setting of System Date Hold down 0 key and then hold down 2 3 LEDs will blink Enter date day month year The up and download PC software displays time and date along with history event Years 1978 through 99 as 78 to 99 Years 2000 through 2077 00 to 77 gt 12 The local date and time is not stored in system memory Adjust date and time after a long power failure LED Indicators Four led lights provide visual indication of System status as well as confirmation of various modes O Red Armed Alarm Indicator Lights up when system is armed and blinks after an alarm is triggered at any zone Blinking indicates alarm history in memory O Green status Indicator Blinks when zone s is are troubled remains lit as long as zones are not troubled quick blinking indicates tamper alarm O Yellow shunt Bypass Indicator Lights up upon zone bypass Note Yellow shunt may light automatically upon arming if Auto Bypass was programmed The indicator also lights and blinks upon Group Bypass entry by pressing 0 twice O Red fire Trouble Indicator Blinks rapidly when a Fire Zone is troubled QO Two led lights Flashing Left Most LEDs In user code programming mode quick blinking indicates code or code index to be entered In Disarmed mode the two left most LEDs are blinking to indicate 24H alarm mode Zone number will also be displayed
33. y is the Enter key 10 When a valid user code is received followed by in your phone the control panel acknowledges it by a special tune Otherwise an error tune is sounded Note Arming the D control panel by the remote user via DTMF is possible even when zones are troubled P Remote DTMF feature requires telephone line at panel side without pote fax or similar connections After control panel acknowledges the user code it will stay ON LINE no longer than 3 minutes providing enough time for the user to perform various operations If the panel does not detect activity it will shorten the ON LINE time and eventually will hang up When the control panel calls your phone during an alarm it will first generate the siren sound for about 30 seconds to shorten time ask your installer The siren sound will stop 10 seconds before the end of the call and a greeting tune will be sounded you can now enter your code followed by To stop the dialer enter 6 to get panel status armed or disarmed enter 7 Reports first zone number to get into alarm beeps count for the zone number enter 7 and 7 To arm the panel enter 1 to disarm the panel enter 2 To end the processes press 9 To Activate a home appliance requires hardware and programming press 3 To learn different tunes call your system and use 8 X then X is the function number 1 Greeting tune It will be heard only once after the control panel answers the c