Home
        End user manual series 2000 & 3000 Rev 6 End User Manual ser
         Contents
1.                                                                                     The Red Armed LED  is on when the  system is armed                                                              Siren 1  poi J Status 3  The Shunt LED    Dela  1               Delete 4 Chime 5 TelephoneO indicates that a zone  Panic Button Test 7 Program 8   Reset 9  1  bypassed        shunt 0    Blinking    h    means  that the system time  is not set  hold down          key    1    key then    0      three LEDs are blinking  enter time in 24 hours format     Hold down functions  To hold down function access  hold down the key for approximately 2 seconds   Hold down function is confirmed by a prolonged beep  Refer to hold down list     1   Siren Test 4   Delay Delete 8   Code Programming   2   Display Bypassed 5   Activate Chime 9   Delete Last key Press  Zones 6   Telephone 0     Display Alarm History  3   Display Troubled Programming   and     Panic   Zones 7   Zone Test    and Display and Setting of System Time  Hold down    0    key    and then hold down    1     three LEDs are blinking  wait for the time to be displayed in  4 digits format    To set new time  hold down key    0    and then hold down    1     Do not wait for time  display  enter the new time in 24 hours format  The local clock time is not stored in  the system memory  clock must be adjusted after power up  After powering up the  system  time is reset to 00 00     h    will be displayed to remind user to set time     h    
2.    000 Three led lights Flashing   In Disarmed mode  rapid blinking indicates AC  power failure  AC power failure event is displayed in Events History as three lines     In Armed mode  rapid blinking indicates system restored after AC Power Failure  mode    During the programming of the    Follow me    telephone number  three flashing led  lights indicate that system is expecting a new telephone number    0000 Four led lights Flashing     Press and hold down key    8     the system is  waiting for code entry    System with bypass via code  Same LED indication when code is expected for Bypass  via code     Setting New Code with AV 701 LED keypad      Hold down key      While four led lights are blinking  enter the master code  default 1234      If code is valid  the four led lights will stop blinking  and    u    will be displayed     The two Left Most LEDs blink to indicate that the system is waiting for a new user   code index  user   to 8  to be entered   5  Enter the code index  1 for code No  1  2 for code No  2  etc    User index will be  displayed for 2 seconds  until further digits are entered  eliminate confusing of  index number and code    6  The two right most LEDs blink to indicate that the system is waiting for a new  code  1 to 6 digits  to be entered  If user code is not entered  the code is voided    7  Enter the new code     U    is displayed for confirmation   8  Wait for    u     small u   To quit code setting  hold down    9       Bb 0 MN    13    pote    
3.    L      Your security system Iuide                y    f  JOUL             EasyLoader Series  2000 and 3000    JUL  f          as VLD     systems ltd     Table of Contents    Table or Contents ii caia 1  Table 0f Contents osas mr tdt 2  A A claus Sau Segue en oa ous tae Seen eae eee ee 3  TPPFOGUCTION EE act a E E es neste 4  SAFETY AND MAINTENANCE INSTRUCTIONS         csccecsseceeseeceseecsecceessecesseecsseeessseceeseeensees 4  GLOSSARY araar lada 4  Basic Operations isnan taps ea E E A A ata ee a ts 8  ARMING YOUR SYSTEM creerii E e ERA EEOAE SEEE eiii 8  DISARMING  IE EE E e 8  AMBUSH DISARMING  ica ie Vaanin EAAS S aaa 8  ZONE BYPASSING acire neniet a aaa n i e a ee i 9  HOW TO BYPASS ZONES vei E ooo ceed E E E E 9  ARMING  OI 9  REMOTE ARMING VIA REMOTE KEY OR DTMF              cccscssessscecessseeeceessececessneaeeeeeeaaees 10  AV 701  AV 702 Keypads  LED a 12  TEDIINDICATOR Sa EA EATA TA A EAT is 13  SETTING NEW CODE WITH AV 701 LED KEYPAD   ccoooccccconocnnononnnncnonnnnncnonnnnnnnnncnnnnnnoss 13  KEYPAD DISPISA REEE EAE AAT A EE co AT 14  DELETE A USER  CODE mirdi aoas a lada A sede Ne 15  SETTING THE FOLLOW ME TELEPHONE NUMBER   cccoooccncconononononononnnonnnnnnconnnnnncnnnnnnnnnnoss 15  PROGRAMMING TELEPHONE NUMBERS    ooccccoconcccononnnnnononononnnononccnnnnnnccnnnnnncnnnn nn nc cnn nnnos 15  SOUNDER taaan veh cele ida Pek Aa a ERA AER atea 15  AV 707  AV 706  AV 705 Keypads  LCD fits PRO  Dublo panels                         16  INTRODUCTION  anaconda a a E 
4.    Sign is displayed   and arming denied   system can not be  Armed with an open  instant or 24H zone     The system is not  responding  keys do  not respond    1  Hold down    9    key until you hear a beep   then enter arming code   2  Program new arming code   3  If you forgot your Arming code  call your  installer   1  Hold down    9    key until you hear the  confirmation beep  Enter arming code  carefully  Do not be confused by Siren  noise    2  System was armed using the Instant  Arming key  key 5   but code was changed    You can ask your installer to cancel this  feature      To disable zone s bypass Arm and disarm  the system  the Yellow indicator light turn  off    Hold down    3    key  the zone s in trouble  will be displayed  Check the cause  an open  window  movement detected by detector or  else    1  Press    0    key  Bypass   and then the zone  number where alarm was triggered    The yellow indicator should light in  confirmation    2  A delayed zone may be troubled  An open  delayed zone will cause the green indicator  to blink upon exit entry       You may have a general power failure   Check your premises fuse box   Warning  If Green indicator is still OFF   your system is operating on temporary  power supplied by the Battery       22    PROBLEM INDICATION REMEDY    Buzzer is activated   Door at delayed zone   Keys    5    or    7    have been pressed  activating  for no apparent  entrance  is open or   the door Chime or the Fault Find function   reason
5.    User    w  user  followed by user number when events log is  displayed and system is in user code programming mode   Arming Denied   Displayed upon Arming attempt with non delayed     or  instant  zones in trouble    Three lines    AC Failure   Displayed after AC failure  in history display at the AV   event 701 keypad  indicating the power fail event       14    Delete a User Code   1  Hold down key   2  While four led lights are blinking  enter code No  1  default 1234    3  If code is valid  four led lights will stop blinking  and    u    will be displayed   4  The two left most LEDs blink to indicate that the system is waiting for a new user  code index  user 1 to 8  to be entered      9      Enter the code index you want to delete  1 for code No  1  2 for code No  2  etc     6  The two right most led lights blink to indicate that the system is waiting for a new  code   7  Hold down    9    key to quit code setting   If user code is not entered  the code is voided  A short beep confirms te    that the code has been deleted  No    Setting the Follow Me Telephone Number   The    Follow Me    feature is applicable only with the dialer  in alarm  Follow Me 1    number is dialed first if the communicator  communicator dials to central station  is   not selected    1  Hold down    6    key twice  wait for the blinking of the three led lights   2  Enter Telephone Number  maximum 16 digits and 4 pauses   and wait until all  led lights stop blinking  The    Follow Me    number 
6.   E    display         Delayed Zone triggering    3 Long beeps         Exit delay starting  if programmed     Warning beeps until the delay is over        Completion of Arm Disarm programming  code    One long confirmation beep        Programming Telephone numbers    Two confirmation beeps        Completion of address programming    Two confirmation beeps        Pressing    Code 7    for driving door opening    Seven confirmation beeps          System Arming with Instant or 24 hour  troubled zone    Five warning beeps   troubled zone          Feature programming    Two confirmation beeps         Follow Me number programming    Two confirmation beeps         During alarm  requires programming           Intermittent beep until alarm reset       AV 707  AV 706  AV 705 Keypads  LcD fits PRO  amp  Dublo panels        Introduction    The AV 707 EasyKey    is the future generation keypad  with the New Look shape   fully customized microprocessor based remote station  multitasking functions with 32  Keypad ID   s  AV 705  706 provide similar functions  For more details  refer to the  AV 707 706 manual  The AV 705 is an economical keypad  its shape similar to the  AV 707 and supplied without the LCD display  The AV 707B contains three extra  keys used for different emergency alarms  fast and convenience 3 home modes  AV   707B is available in Metal Gold or Silver color  The AV 707  706 and 705 fits only    PRO and Dublo type control panels     16          After power failure     Set P
7.   zone     a       three lines  sign will be displayed  indicating that the system is disarmed  warning about an open  troubled  zone     Instant Arming   The Instant Arming feature allows you to press    5    key to arm the system    This command is designed to allow user to arm the system without needing a full user  code     Note  The instant arming is not recommended  This will allow easy  0  arming by someone who is not a regular user  0    Auto Arming   This feature provides setting of the desired system arming time when the regular user  is away  Auto Arming is useful for shops and sites requiring long exit delay    Enter to user programming mode  hold down    8    key then enter your master code   three led lights will blink    Hold down  8    A  is displayed   Enter the time in 24 hours format    To display  hold down  8  and wait    To disable Automatic Arming program  press 0000    After Automatic Arming is programmed  the system time can be set only via User  Programming Mode  Enter User Programming Mode  hold down    8    and 1234   hold  down  1    t  is displayed  and type hour and minutes  Hold down  1  and wait for the  time to be displayed  Holding down  0   1  keys to program the time is possible only if  the Automatic Arming is disabled  otherwise an  Error    warning is displayed    Automatic Arming will not operate if the system time has not been set  blinking  h     Automatic Arming will not operate if the control panel is already armed    Automatic Arm
8.  there has been Arm and disarm the system    detection of Hold down    9    key to reset Day Zone or   movement at an Tamper alarm   exit entry zone    Day or Tamper zone   was activated  Entry at protected A warning signalis   Disarm system immediately upon entry at  zone activates mini    heard before the zone  If delay time is too short  call your  sounder at keypad siren is triggered installer to reprogram delay time       L    is displayed Battery is low  Call your installer immediately  faulty  or dead       C    is displayed Telephone line Call your installer immediately  Check your   blinking  disconnected or dead   telephone line  or the systems failed  to contact central  station  Siren was triggered    1  Faulty dialer 1  Hold down    6    key  dialer test    but programmed 2  Faulty phone line   automatically dialed numbers will be  phone numbers were   or phone off the displayed  test takes several minutes    not dialed hook 2  If the telephone line to the alarm control  3  Mistaken report of   has been disconnected  reconnect it   alarm 3  Malfunction of the alarm system   call  your installer       H    is displayed  A panic alarm was Arm and disarm system to abort alarm and     h    is blinking  activated  Take H display    emergency Set system time by holding down    0    key   measures  Blinking   then    1    key      h     set the time  Yellow indicator    Automatic Bypass      Before arming  make sure all entry exit  lights upon arming has been doors prot
9.  to display the last    alarm sequence  New alarm will erase the old events     De and Detailed Events History  requires programming   Hold    down    0    and again hold down    0    to display up to 99 events  like  System opening  and closing by user number  opening or closing time  zone caused alarm and AC  failure  Your PRO panel stores up to 250 events displayed by the EasyLoad program   the keypad display 99 events only    By holding down key twice  three LEDs start blinking  indicating a special  operation mode  The events are displayed from the most recent events to the oldest  ones     3  and Display Last 2 Users  Hold down    0    and then hold down       5    to display user number and System opening or closing time      o    is displayed for Opening  Disarming      c    is displayed for Closing  Arming      19    Events Display   Events are displayed as following    XX   Event number  from 01 to 99   then HH_MM  Hour and Minutes  Event Time   Event  alarm or opening closing     Translate the display as following       u     user number 1 to 8        o    or    C      opening or closing   Zone causing alarm will blink twice   X   Tamper alarm from zone causing the alarm  X    H   Panic Alarm   Note  three lines     indicate power failure  An AC failure event will be displayed  during history events    For detailed log events ask your installer to download the log events via EasyLoad  software     Trouble Conditions  The system constantly monitors itself to ensure 
10. Keypad display   The 7 segments  also called LED keypad  display provides visual readout of the  system status  The display indicates zones in alarm  troubled zones  bypassed zones  and displays the following confirmation letters       Display   Description Function    Up  amp  Download Modem    Answer Now    function selected  Confirms hold   down    6    key then hold down    1    key      A    also displayed upon Auto Arming programming       Communication Displayed at dialer tests  and upon holding down    6    key   Communication C flashing in display indicates telephone line trouble   Chime Confirms Chime mode via    5    key   Closing When events log is displayed Indicates Arming followed by  user number   Delay Delete Confirms Delay Delete Upon holding down    4    key    Dial Delay When programming telephone number that requires an inter   digit delay     Pause     during dialing   Delay duration is 2  seconds     Error Indicates programming and operation error   Home Indicates entering of Home Mode  Group Bypass    Hour Displayed after power up to remind user to set the system  time     h    will be removed after time setting  using keys 0  and 1     Hold Up Upon Panic triggering from Keypad   Opening Indicates system opening  Disarming   Followed by user  number when events log is displayed   Low Battery Indicates Low Battery     Call your installer   Program System is in programming mode   Tamper Indicates zone s Tamper alarm   Update Confirms programming updating
11. all   or calls the user   It indicates that the panel expects a valid user code    2    User code  accepted    3    Error    Will be sounded in the following cases  Incorrect user code  command  not defined valid  incorrect input  trying to bypass an undefined zone  command could  be not carried on  on line time out or call ends    4    Confirmation    Will confirm that the requested action has been carried out    5    Armed    Control panel is Armed    6    Disarmed    Control panel is Disarmed    7    Alarm On    Control panel is in Alarm position  This warning will be sounded  from time to time during idle periods    Remote DTMF function example   For example  let   s assume that your kid arrived home and he cannot disarm the alarm  panel       Call your alarm telephone number  tell the kid not to pick up the phone      After a few rings  your system answers  A greeting tune is heard        Enter your user code  123 4       Confirmation tune is heard  If alarm is on  siren tune is heard      Press 2   and wait for the confirmation tune     To re check the system status press 7   and wait for the system status tune    In case the system is still on  re enter 2   or try to enter your user code  then 2       11    AV 701  AV 702 Keypads  LED type        AV 702 keypad contains identical keys and LED structure to AV 701        The Status LED is on    I AV GAD EASYLOADER AV 701   when all the zones  A are closed   ZONE     ARMED STATUS SHUNT FIRE DISPLAY                         
12. anel Time    is displayed  To set time hold down    0    key    then Hold down    1     enter time in 24H format and press    To set the date  hold down       0    key then hold down    2     enter date in day month year  format and     The AV 707 keys and Hold Down functions are identical to the AV 701 functions   you can speed up the function by pressing         key     the ENTER key     The sounder and Led lights and indications are the same as described for the    AV 701     s  The mx key in LCD keypads is mostly used as an ENTER key  pote    typed at the end of a command    LCD display    The LCD display helps understanding the system status and zone locations by reading    in plain text the system messages  zone description  time and other indications     The first row displays system announcements  like  System Disarmed  Alarm  Low    Battery  etc   second row displays the zones  status    Each           sign represents a zone  If a zone is  open  the zone   s number like 123   567    will  replace the        If a zone is bypassed a     appears instead  The  control panel time is displayed in the five  rightmost positions     The LCD displays often the installer LOGO  the  logo is editable   For displaying zone description  hold down    3    key twice    To save power  the LCD and keys backlight turns  OFF after 60 seconds of no typing activity  it  turns ON again when an alarm occurs            System Message       7D       System isarmed         3       12 00       a
13. attempts to enter an invalid code  the  keypad locked itself for 30 seconds    20    pote    Delays Delete    Delay  Key 4  gt  DELAY DELETE  INSTANT PROTECTION   Cancels the Entry Delay in zones selected as    Delayed    zones  All zones become  Instant  This feature is optional when Home Mode set and all users are in  Hold down     4    key     d    is displayed in confirmation  Instant Protection becomes effective only if  System is armed within 20 seconds following hold down of    4    key     Key 5  gt  DOOR CHIME    The Door Chime initiates the keypad to beep whenever a zone is activated  Door  Chime operates on Chime programmed zones    Hold down key 5 enables and disables the function    Chime mode is confirmed by    c    displayed on keypad     and L 4   gt  LOCAL BUZZER ON and OFF    Holding down keys  0  and     simultaneously turn on and off the buzzer in each  LCD keypad  This function works in disarmed mode     Testing Your System       It is recommended to test your system daily or weekly  Perform  system tests in the off peak hours  such as early morning or late  evening  Call to inform your monitoring station that you are testing  your system     Siren and Battery Test   Hold down key    1     This command will generate a siren sound for 2 3 seconds    Turn off your main AC  verify that LEDs are blinking to indicate power failure  test  siren again to make sure your battery can drive the siren during power failure    Arm and Disarm the system  main AC is stil
14. der   The sounder  in Keypad  simplifies alarm recognition by producing different amounts and  sound patterns to identify various events  The sounder also functions as key press  confirmation     Siren   The siren generates noise and light indication  when strobe included  in order to indicate  burglary  fire or other emergency cases  It   s recommended to install a siren indoor and  outdoor of the protected site     SMS Message  Short Message Service  for series 3000   SMS is the text communication service component of series 3000 alarm panels  in case of  alarm or other selected events the alarm system sends you the same message displayed on  your LCD keypad to your SMS enabled phone  The transmitted events are programmable     User Codes  One master and seven codes are available to allow users to arm and disarm the system and to  bypass zones  Keep the code confidential to ensure maximum system security     Zone  also called Area    An area protected by a security device  For example  a room protected by a motion detector  as Zone number 1  while a door protected by a magnetic contact as Zone number 3  Your  installer will inform you which zones have been set up on your system  The AV 701  contains a zone index list  The AV 707 LCD keypad displays the zone description  like     Garage        Jimmy   s Room     etc     Basic Operations       Arming Your System   Before arming your system  close all protected doors  windows  and do not move  around areas protected by motion 
15. detectors  When all protective zones are closed  the  Green Status LED stops blinking  Exit door and other delayed zone may stay open  upon exit the protected areas     To arm the system  enter your code  At each digit entry  the keypad sounder will beep   When the code has been entered  the Armed LED will light  If an incorrect user code  is entered  the keypad will sound a single long tone  To correct the mistake  press    9     and enter the code again     When the Armed light is on  leave the premises through the designated entry exit door  before the exit delay expires  At the end of the exit delay  all lights on the keypad will  be shut off  except for the Red Armed light  Your system is now armed     The factory setting for the exit delay is 30 seconds  your installer may change this  time to suit your needs  Refer to the Arming Options section of this manual for  information on other arming functions     Disarming   Enter the premises through the designated entry exit door  The keypad will sound a  constant tone to indicate that the system must be disarmed    Enter your code at keypad  if an error made while entering the code  press    9    and  enter the code again  After six wrong entries  the keypad locks itself for 30 seconds   keys do not respond during this period    When a correct code is entered  the armed light shuts OFF  and the sounder is silent   Y our system is now disarmed    Enter your code before the entry delay expires  to prevent alarm   The factory 
16. e Siren Times Silent Zones  Notes             EasyLoader  Series  Alarm Control Panels    End User Operating Manual 5    For version 2 18 up to 3 06     Congratulations for purchasing this state of the art computerized security panel  You  have made a wise investment in the future safety of your home or business premises  with this high technology security system  however it   s still as EASY as 1 2 3    If you have one of the new series 3000 alarm refer for details regards the SMS in  the system technical manual     Introduction    Review this manual carefully before operating your security system    Y our installer should instruct users how to operate the system and about it   s various  features  Complete the System Configuration page and store this manual in a safe  place for future references        Safety and Maintenance Instructions   Y our security system cannot prevent burglaries  emergency cases or damage to your  property  It is only intended to alert emergencies    To keep your system efficient as intended  it is recommended to test the system daily  upon arming and weekly testing the siren and detection devices  Read the    Testing  your System    section  If your system does not function properly  contact your installer   Keep the keypad dry  clean the keypad with dry cloth  Never disconnect the main AC  to your system     Glossary   Your security system has been designed to offer the latest security features with  simple and easy operation  Described here  are 
17. ected by system are closed and all  of system  without programmed  Can detectors are off  Arm the system  and call  bypassing  pressing   also occur if    0    key   your installer  0 and any key  is pressed twice   before arming    which activates zone   bypass       23    WARRANTY    AV GAD LIMITED WARRANTY    Av Gad Systems Ltd   Av Gad  warrants its products to be free from production  defects in components  materials used and labor  for the period of twelve months  following the date of production  Av Gad will within the mentioned period  as its  option  repair or replace any product failing to proper operation without charge     This warranty shall not apply to any equipment  or any part thereof  which has  been repaired by others  installed not properly  used improperly  abused  altered  damaged  subjected to acts of God or on which the serial and data code altered or  removed     Av Gad will not be responsible for any dismantling or reinstallation expenses  In  order to exercise the warranty  the product must be returned by the purchaser   delivery and transportation costs prepaid and insured to Av Gad     After repair or replacement  Av Gad assumes the cost of returning products under  warranty     There are no warranties  express or implied  which extend beyond the description  of the face hereof     There is no express or implied warranty of merchantability or a warranty of fitness  for particular purpose  Additionally  this warranty is in lieu of all other obligat
18. erecto lcd cerca bicis as 16  ECDDISPLA ec ici 17  KEY ENTRIES 4 ad a ao teca canela dad cr redes al o 17  SETTING NEW CODE  amp  GROUP BYPASS WITH AV 706  707 KEYPADS  cccononcncncninononononons 18  SETTING FOLLOW ME TELEPHONE AT AV 706  707   ooconocococonononononanononannnonononononononononons 18  Displaying System Information tii ia ibid 19  ALARM MEMORY DISPLAY oare e AI NAE O AENA AE ATE SAER 19  EVENTS  DISPLA Vi a AAS EA EE ee 20  TROUBLE CONDIT ON Sica ctra VE AE VTE TEREE E 20  Setting System Features neaei a aa a aa ias 20  CHANGING CODES hrie aaa n da little 20  DELAYS DELETE AEE E A E dad AE E AN A E E A 21  Testing Y our Systemin on u a deat ive asl E sE 21  SIRFNAND BATTERY TEST 0d a a ON EE AI ds 21  DETECTION DEVICES TEST iaa aa 21  TESTING YOUR CENTRAL STATION  CS      cccscecssessseesseesseeseeceeceaeceaecnseeeseeseeeeeeeeneeeaeenaes 22  ME OUTS OLS Fe 55 IEEE on caos 22  AV GAD LIMITED WARRANTY seai aaa a a aa a 24    Item  4716  A4BKE   Rev 6      All Rights Reserved to AV GAD SYSTEMS LTD  Tel Aviv  Israel  POB 49 080 Tel Aviv 61 104  Israel    W7  END_2000_Rev 6 large  May 2011     System Configuration                                                                                                 Zone Index  Zone Description Type Zone Description Type  1 9  2 10  3 11  4 12  5 13  6 14  7 15  8 16  Installation Data  Installer CS Information Programmed Telephones  Phone  Phone   Mobile  Account No    Installation date  Contact Person   Zone s at Home Mod
19. hortening for the most common dialing protocol    Dual Tone Modulated Frequency     Av   Gad panels use the DTMF for dialing and in latest alarm panels also used for remote  commands like Arming  Disarming  Zone Bypass  and some more functions     Digital Display  Keypad enhanced LED 7 segments display  Provides alphanumerical readout of zone status  and messages     Entry Delay  The Entry Delay is the period allowed for someone to enter the premises and disarm the  system     Entry Exit Zone  The entry exit door or zones are designated by your installer to be used for entering and  leaving the premises when the system is armed     Exit Delay  The Exit Delay is the period allowed for users to leave the premises after arming the system     Fire Zone   A zone programmed for connection of fire or smoke detector  Alarm heard in both Armed  and Disarmed modes  and Fire LED is activated    The siren sound is different from the 24H zone or burglary alarm  it depends on the siren  type used   To reset Fire alarm  hold down  9    key and your code        Follow Me    Programmable Telephone Number  Follow Me it   s a dialer feature  The desired Follow Me Telephone number is programmed  by the user prior to arming     as necessary  to follow the user destination      Follower Zone  also called conditioned Zone   Follower Zone reacts instantly upon detection without previous triggering of Delayed zone   Exit delay applies to Follower zones and Delayed zones     Hold down Functions  Holdi
20. ing will operate even if the control panel is currently in ALARM   When the Automatic Arming programmed time arrives  the system starts at a 30   seconds countdown  An  A  is intermittently displayed and beep sounds at keypad   During the countdown period  the Automatic Arming can be aborted by entering a  valid user code  not code No  7  if used to    open    a door      Remote Arming via Remote Key or DTMF   The Remote Arming allows you to use a remote key switch  or wireless  Av Gad set  AVS22  tiny transmitter to arm the system  This command is designed to arm the  system without a code  or for convenient arming from your car  Remote functions  with DTMF       D    suffix  D for DTMF  alarm panels type provides certain remote functions    The DTMF remote control functions      gt  Check the control panel status  Armed Disarm  Alarm in progress      gt  Inform the zone number that caused alarm  beeping the zone number on the phone    gt  Arm and disarm the control panel     gt  Bypass zones or clear all bypassed zones    gt  Stop the dialer report during alarm     gt  Momentary activate Al  alarm  output for three seconds    Verify with installer that the system is programmed to answer income calls    To get on line  dial to the control panel  The control panel will answer the call after  the number of rings  as programmed   When answering the call  control panel sends a  greeting tune sound  enter your user code within 5 seconds  1234  and confirm  pressing the         ke
21. ions  or liabilities on the part of Av Gad     Any action for breach of warranty  including but not limited to any implied  warranty of merchantability  must be brought within three months following the  end of the warranty period  In no case shall Av Gad be liable to anyone for any  consequential or incidental damages for breach of this or any other warranty   express or implied  even if the loss or damage is caused by the seller   s own  negligence or fault     Av Gad is not an insurer of either the property or safety of the user   s employees   family  or 3rd part and limits its liability for any loss or damage including  incidental or consequential damages to Av Gad original selling price of the  product regardless of the cause of such loss or damage  pot    Av Gad recommends testing the entire system weekly  Refer to  Testing Your System section for further details     WWW av gad com    24    
22. is now programmed   3  To delete    Follow Me    number  access    Follow Me    programming mode as described  in paragraph 1  but do not enter any number    Programming Telephone Numbers   1  Hold down key 8   2  While four led lights are blinking  enter the master code  default 1234    3  If code is valid  four led lights will stop blinking  and    u    will be displayed   4  The two Left Most LEDs blink to indicate that the system is waiting  hold down  keys  6   1  for first number   6   2    6   4  followed by the telephone number      U    is displayed for confirmation  If number not entered  the system will display the  telephone number  To erase a number hold down continuity  6   hold down  1   then  hold down    9    to erase the first number  wait for    u     to quit setting  hold down    9        Sounder   The Keypad sounder enhances the use of system operation and serves as a local alarm  device  requires programming     Several programmable features set the sounder functionality  Ask your installer for  more details     15    With AV 705  706  707  LCD keypad  the user is able to switch the buzzer on and off  at each keypad  Holding down keys  0  and     simultaneously turn on and off the    internal buzzer     The sounder emits sounds in the following instances        OPERATION          SOUNDER RESPONSE           Pressing of any key    Short confirmation beep         Hold down functions    Long confirmation beep        Faulty programming input    Long beep     
23. l off  few times  if    L    is displayed  your  battery is faulty  call your installer     Detection Devices Test       Tes 7  Key 7  gt  FAULT FIND    e Fault Find enables testing of all detection devices    e Fault Find mode can be entered only during the 15 seconds following system  Disarming    e Fire  24H  or Panic alarm will stop Fault Find mode    e Hold down    7    key  confirmed by    F    on Keypad display    e Activate each sensor  Detection of zone opening is confirmed by a one second beep   Three beeps indicate zone closing    e Arm the system to quit Fault Find mode     21    pot       Testing your Central Station  CS   Inform your CS that you perform testing  ask them to report you if an alarm is  received  Arm the system  move in front of a detector or open a protected door  verify  that the siren is activated  to quit testing  disarm the system     poto    Test your system daily   Call your installer if any test fails to operate    Troubleshooting       PROBLEM INDICATION REMEDY    System fails to Arm  when code is entered  at Keypad    System cannot be  disarmed    Yellow indicator is  on  indication that  zones have been  bypassed    Green indicator  blinks continuously  when you attempt to  arm the system    Three LEDs  indicators are  blinking  indicating  Power Failure    Keypad entries are  confirmed by beeps   but system does not  react    Arming Disarming  code is entered but  Red indicator  remains lit    Yellow  shunt   indicator constantly  on   
24. mber  1 to 8  or 1 to 16 in AV 2016    the Shunt  Bypass  Yellow light is on in confirmation  enter your arming code  Armed  Red LED goes on     To remove a bypassed zone  arm then disarm the system  re enter the bypassed zones     When you arm your system  the zones you have indicated will now be bypassed   When arming the system with bypassed zones  it is always recommended to review  the list of bypassed zones before entering your code to arm the system  After  bypassing the desired zones  enter your code to arm the system     Arming Choices   Group Bypass  Home Mode    Arming with Home mode  automatically bypasses the zones programmed as Group  Bypass  This feature allows you to arm the system and remain on the premises    For new systems  version 2 17 and later  To bypass first group  press    0    and hold   down    1     to bypass second group  press    0    and hold down    2     to bypass both  groups  press    0    and hold down    0     AV 707B keypads are most convenient for  arming with home mode  one button press for group bypass and arming    At    Home Mode    another person would still be able to enter the premises through the  entry exit door without causing an alarm  requires special programming   To disarm  the system when the entry exit door is opened  enter your user code     Away Arming   Close all protected doors and windows  you can move in front of the delayed detector   Enter your code and check if the Armed LED is on  In case of arming with an open
25. ndicating that data is expected   in this case the new User Code      12345667  12 00 Js ees   Enter a one to six digits code  Key      0000 corrects the input press  as backspace or  Hold Down key  9   reset  to cancel the input     Press     key  as ENTER  for confirm     The control panel will verify that the new  code is not in use by other user  if that  happens you ll be notified  and respond by    DOGO       displaying the code  At any time after the  control panel response  you can start typing a  new index  there is no need to wait for the  announcement to disappear     To erase an existing code  Enter user index  number  01  02  03       hold down  simultaneously keys     and       followed by     E  erased  will be displayed    The Master  code number 01  cannot be  erased  Type  99    followed by   to exit User Programming mode     Setting Follow Me Telephone at AV 706  707   To display the Follow Me telephone number  hold down  6   type     for faster display   and the control panel will display the number  or the  empty  announcement if there is  no telephone number currently programmed     To program the Follow Me telephone number Hold Down twice the  6  key  The three  Rightmost LEDs blink  indicating that the keypad waits for input     18    On the upper display line  a blinking cursor will appear  type the number  digits from  0 to 9   hold down   for     digit  hold down  0  key for Pause  a    P    will be displayed   or press simultaneously      amp      
26. ng down keys for about 2 seconds provides additional easy to access functions     Instant Arming  System Instant Arming  Short press on key 5 instantly arms the system     Instant Zone  Zone feature  The system reacts instantly upon detection at a zone which has been  programmed as    Instant        Key switch  optional   Located on control panel door or remote panel  Used for arming disarming the system     Keypad   Your system contains one or more keypads  The keypad is used to operate the system and  display information about the system  Commands are entered on the keypad by pressing one  key at a time     LCD  Shortening for    Liquid Crystal Display     This type displays full texts  zone locations   messages  etc  AV 706 and AV 707 are LCD type keypads     LED  Shortening for    Light Emitting Diode     LED is a modern bulb  LED visually displays the  system status and confirms the functions     Master Code   The Master Code is a 4 to 6 digits code  is used to arm and disarm the system  to program  your codes and to bypass zones  in certain models   Normally  only one person should know  the Master Code  Your default master code is 1 2 3 4     Panic Button  Two keys    and    on the digital keypad  for alerting the central station in case of  emergency     Programmable Features  Computerized control panel allows system tailoring to suit individual requirements     Smoke Detectors  Triggers alarm upon detection of smoke  Smoke detector requires reset after alarm     Soun
27. proper operation  When a trouble  condition occurs  the system condition will be displayed                             Indication Cause To do     L    or Low Battery on Battery is low Call for service  Four LEDs are blinking   AC power failure Check the premises fuse  box  Call for service     C    or    Tel  Line Fail    Telephone line test failed   Call for service  Arming fail and   is   Zone is troubled Bypass the zone and call  displayed for service          Setting System Features       Changing Codes   The system features eight programmable codes  The first code is the Master Code  and  the remaining seven codes are normal arming and disarming codes    Do not use    0    as the first digit in a code    Do not use    5    as first digit in a code number if Instant Arming via key 5 was  programmed    User code shall not start with the same numbers as the installer programming code   1994     Do not use same codes or same first digit for different codes  For example if code No   one is 1234  programming code No  2 cannot be 1256    Key Visual Feedback   Visual    feedback    from the keypad display upon entering of  code  This feature indicates the code entry progress and is most practical when the  keypad buzzer is disabled at Home  Group Bypass  mode  or if selected by  programming  Entry of code by user or installer is confirmed at keypad display   Display segments will light up clockwise  indicating the sequence of the entered  digits     Note  After six unsuccessful 
28. rmed   Status   shunt   fire        Bypassed Zone  Close Zone  Open Zone  Time  AV 707       Most of the accessible functions with the LCD Keypad are similar to those of the    AV 701  seven segments keypad    Key Entries    Keys typed at the keypad are concealed  as they are part of the User Code                signs are displayed     In Armed and Disarmed mode  after six attempts to enter fault code  the keys will not    respond for 30 seconds  in order to prevent code break exigency     During all kinds of programming  keys are displayed as they are typed  some    combinations are exceptional      17    Setting New Code  amp  Group bypass with AV 706  707 keypads    To enter User Programming mode     Hold Down    key  8   program     The three Rightmost LEDs start blinking  enter the Master User Code  factory default  1 23 4  followed by    Enter   The upper line displays  User Programming  the lower  line is cleared and a blinking cursor appears    The Leftmost two LEDs will start blinking indicating that    location    is expected  In  this case  location means    User Code    index to be modified  erased or programmed   User Index means User Number 1 8  as system contain eight different user codes   Enter a two digits number from 01 to 08  2 digits required   After the index had been    A e    SYSTEM DISARMED    entered  the    location      the upper line is  cleared  the blinking cursor moves to the  beginning of the line  three Rightmost LEDs         start blinking i
29. setting  for the entry delay is 12 seconds  your installer may change the time to suit your  needs    If an alarm occurs while the system is armed  the Armed LED blinks  Refer to     Display Alarm Memory    for instructions on displaying the zones in alarm     Ambush Disarming   If you are forced by an intruder to disarm your system  the Ambush alarm can be  activated  Disarming the system with the Ambush code will cause the system to  disarm and simultaneously send a silent ambush alarm signal to central Station  This P  is an optional feature  For details ask your installer  pot       IMPORTANT  If you return to the premises and find that an alarm  is in progress or there are alarms in memory  do not enter the  premises  as an intruder may be present  Contact local authorities  from your mobile or public phone     Zone Bypassing   A    Bypassed    zone will not cause an alarm  Zones may be bypassed to allow access to  part of the protected area while other zones are armed  For example  you could bypass  the zone protecting your living room  This would allow you to remain in the room   while the other zones on your system are armed     With the system disarmed  hold down  2    key to display bypassed zones  The zone  number displayed represents bypassed zones  Ensure that any zone displayed as  bypassed is intentionally bypassed  Zone bypasses are automatically cancelled when  the panel is disarmed     How to Bypass Zones   To bypass a zone  press    0    key and the zone nu
30. some terms that are used throughout  this manual to explain the common terms     Group Bypass    In certain countries called Home mode       Group Bypass    allows bypass of few zones determined by the installer to be bypassed  at once by entering a short keys combination prior to Arming  AV 707B is most  convenient keypad for simple    one key press    for Group Bypass and Arming     24 hour Zone   A zone programmed for 24 hours protection  Zone is active in both Armed and  Disarmed modes  When a 24 hours zone is troubled  alarm will sound in both Armed  and Disarmed mode     Battery  Standby rechargeable battery located in the control box  provides emergency backup  power in case of power loss     Bypass  Shunt  a zone  Allows manual removal of one or more protected zones from the system     Day and Tamper Zone   A zone programmed as a    Day    or    Tamper Zone    enables alarm from keypad s buzzer  during daytime  when system is usually disarmed  The    Day    or    Tamper zone    will trigger  the keypad buzzer and the zone number will flash on keypad display  To reset    Day Zone     alarm  hold down key 9  reset key     During Armed mode  this zone will act as burglary zone and will emit an alarm when  troubled     Dialer and Communicator   Alarm reports directly to predetermine stations via telephone lines  The dialer reports an  alarm to your telephone  a siren or a recorded message  To report a recorded message the  SVM 40 electronic module is required     DTMF   S
31. to erase the phone number  a  E  will be displayed    To correct the input you can use the     as a backspace erasing key     Group bypass  home mode        If you want the system to disable few zones during night time for example  ask  installer to define a group bypass zone s  Bypass is operative only if System is armed  within 60 seconds from the entry of this feature  Yellow LED will flash and    h      Home  displayed for 1 second in confirmation  Commands to bypass group of zone s    e 0  amp  hold down key 1   Arm with group 1 bypass  or 0 0   Group 1 Bypass   e 0  amp  hold down key 2   Arm with group 2 bypass  or 0 0 0   Group 2 Bypass   e 0  amp  hold down key 0  Arm with group 1 2 bypass  or 0 88   Group 1 2 Bypass  Each command works as a toggle SET CLEAR  The AV 707B  with extra 3 keys   keypad provides arming and group bypass by pressing   than hold down one key   Button A  most left   Selects Group Bypass No  1  if programmed so  and arms the system   Press   key than hold down key A  For AV 707  without 3 buttons  press 0 and 1  Button B  Selects Group Bypass No  2  if programmed so  and arms the system  For AV 707  without 3 buttons  press 0 and 2  Button C  Selects both Group 1 and Group 2 and arms the system        Displaying System Information       Alarm Memory Display  Alarms generated when the system is armed are recorded in the system s memory   Press key    0    to display the zones in alarm     l  Concise Alarm History  Events Log   Hold down    0   
32. will  disappear after the new time is set     Shunt  and Display and Setting of System Date  Hold down    0    key    and then hold down    2     3 LEDs will blink  Enter date     day month year     The up and  download PC software displays time and date  along with history event   Years 1978 through 99 as 78 to 99  Years 2000 through 2077 00 to 77     gt        12    The local date and time is not stored in system memory  Adjust date  and time after a long power failure     LED Indicators   Four led lights provide visual indication of System status as well as confirmation of  various modes    O Red Armed Alarm Indicator   Lights up when system is armed and blinks after  an alarm is triggered at any zone  Blinking indicates alarm history in memory    O Green status Indicator   Blinks when zone s is are troubled  remains lit as long as  zones are not troubled  quick blinking indicates tamper alarm    O Yellow shunt  Bypass  Indicator   Lights up upon zone bypass     Note  Yellow shunt may light automatically upon arming if Auto Bypass was  programmed     The indicator also lights and blinks upon Group Bypass entry  by pressing    0    twice    O Red fire  Trouble  Indicator     Blinks rapidly when a Fire Zone is troubled    QO Two led lights Flashing  Left Most LEDs    In user code programming mode   quick blinking indicates code or code index to be entered    In Disarmed mode  the two left most LEDs are blinking to indicate 24H alarm mode   Zone number will also be displayed 
33. y    is the Enter key      10    When a valid user code is received  followed by   in your phone  the control panel  acknowledges it by a special tune  Otherwise an error tune is sounded  Note  Arming  the    D    control panel by the remote user via DTMF is possible even when zones are  troubled  P  Remote DTMF feature requires telephone line  at panel side  without pote  fax or similar connections    After control panel acknowledges the user code  it will stay ON LINE no longer than  3 minutes  providing enough time for the user to perform various operations    If the panel does not detect activity  it will shorten the ON LINE time and eventually  will hang up    When the control panel calls your phone during an alarm  it will first generate the  siren sound for about 30 seconds  to shorten time ask your installer   The siren sound  will stop 10 seconds before the end of the call and a greeting tune will be sounded   you can now enter your code followed by    To stop the dialer  enter 6    to get panel  status  armed or disarmed  enter 7    Reports first zone number to get into alarm   beeps count for the zone number  enter 7 and 7    To arm the panel enter 1    to  disarm the panel enter 2    To end the processes press 9    To Activate a home  appliance  requires hardware and programming  press 3      To learn different tunes call your system and use 8 X then   X is the function  number     1  Greeting tune  It will be heard only once  after the control panel answers the c
    
Download Pdf Manuals
 
 
    