Home

DUAL TECHNOLOGY DETECTOR

image

Contents

1. WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE DO NOT INSERT ANY METALLIC OBJECT THROUGH THE VENTILATION GRILLS OR OTHER OPENINGS ON THE EQUIPMENT Apparatus shall not be exposed to dripping or splashing and no objects filled with liquids such as vases shall be placed on the apparatus CAUTION These servicing instructions are for use by qualified service personnel only To reduce the risk of electric shock do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so English _2 CAUTION A RISK OF ELECTRIC SHOCK AY DO NOT OPEN CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER OR BACK NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL English _3 EXPLANATION OF GRAPHICAL SYMBOLS The lightning flash with arrowhead symbol equilateral triangle is intended to alert the presence of dangerous voltage within th enclosure that may be of sufficient magniti risk of electric shock to persons within an user to the e product s ude to constitute a The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the product Please read the following recommended safety precautions carefully e Do n
2. TAMPER TAMPER OUTPUT PORT Sie SiS LI LI ALARM 12V GND TAMPER 0 5m 3m 5m 7m 12m Side view 2m Am 6m 8m 10m 12m Top view English _10 Specifications amp Appearance Specifications Item Description Detection Range 110 x 12m Installation Height 2 2m Auto Temp Compensation 0 Pet immunity PIR Sensitivity 0 Selectable Pulse Count 0 Input Voltage DC 9V 16V Current lt 30mA Power Consumption 0 36W DC12V English _11 Item Description Alarm Output N C N O Tamper 0 Operating Temperature 10 50 C Operating Humidity 95 max Dimensions W x H x D 130 x 65 x 53 3mm Weight g 1339 English _12 Appearance 53 3 Unit mm sin English _13 lt eco RoHS compliant Samsung Techwin cares for the environment at all product manufacturing stages and is taking measures to provide customers with more environmentally friendly products The Eco mark represents Samsung Techwin s devotion to creating environmentally friendly products and indicates that the product satisfies the EU RoHS Directive z Correct Disposal of This Product Waste Electrical amp Electronic Equipment Applicable in the European Union and other European countries with separate collection systems This marking on the product accessories or
3. e product may not perform as expected The user is advised to take all necessary precautions for his her safety and the protection of his her property Product Features Adopted MCU Automatic pulse count Streamline design Doppler Power analysis X Band plane antenna Microwave detecting range adjustable Auto temperature compensation reducing false alarm Valve adjustable technology with high anti interference Unique look down design without dead angle N C N 0 optional for different alarm Intelligence technology differing intruder from interference signals SMT technology English _6 IR Sensor at a Glance 1 Wire exit 2 Terminal block 3 Microwave module 4 Yellow LED 5 Red LED 6 Green LED 7 LED jumper 8 RELAY jumper 9 P COUNT jumper 10 Dual PIR 11 Microwave VR 12 Tamper English _7 Installation 1 Fix detector bracket to wall Remove front cover of detector take out PCB fix back cover to bracket with screws the best installation height is about 2 2m 2 Setthe PCB in the back cover after connecting the wires according to the TERMINAL BLOCK FIGURE full stop close the front cover 3 Avoid installing the detector close to the following sources of interference reflective surfaces direct air flow from vents fans windows sources of steam oil vapor infrared light sources and objects causing temperature changes such as heater
4. literature indicates that the product and its electronic accessories e g charger headset USB cable should not be disposed of with other household waste at the end of their working life To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate these items from other types of waste and recycle them responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take these items for environmentally safe recycling Business users should contact their supplier and check the terms and conditions of the purchase contract This product and its electronic accessories should not be mixed with other commercial wastes for disposal
5. ot Place this apparatus on an uneven surface e Do not install on a surface where it is exposed to direct sunlight near heating equipment or in extremely cold area English _4 Do not place this apparatus near conductive material Do not attempt to service this apparatus yourself Do not place a glass of water on the product Do not install near any magnetic sources Do not block any ventilation openings Do not place heavy items on the product User s Manual is a guidance book on how to use the products The purpose of using symbols in the manual is as follows Reference To provide information for help in usage of products Notice If any possibility exists to cause damage to goods persons as a result of not following the instructions Please read this manual for the safety before using goods and keep it in the safe place Note 1 Please install and use the detector following the directions Do not touch the sensor surface as this could result in a detector malfunction If necessary clean the sensor surface using a soft cloth with pure alcohol English _5 Avoid using products in areas with huge change of temperature The user should follow the installation and operation instructions and among other things test the product and the whole system at least once a week For various reasons including but not limited to changes in environmental conditions electric or electronic disruptions and tampering th
6. s refrigerators and ovens Avoid installing the detector in the direct sunlight 4 Ensure no object is in front of the lens of the detector the look down window must face down English _8 Testing and Usage 1 With 12V power supply the detector is set into self checking state and the LED ON the LED is off after 60 seconds and the detector is set into operating state Conduct walk test in detecting range different LED ON Green LED ON infrared is ON Yellow LED ON microwave is ON Red LED ON infrared amp Microwave is ON and the detector is in alarm status RELAY jumper is used to set alarm output mode Select different output mode depending specification of control 182 N C 2 amp 3 N 0 182 N C is set as factory default Microwave VR is used to adjust the detecting range of microwave according to customer s request The largest detection range is set as factory default LED jumper is used to control LED indication without interference to detector LED ON jumper can be interrupted after testing for concealment P COUNT jumper is used to select the first and second pulse Connect 1 amp 2 to 1P the first pulse 2 amp 3 to 2P second pulse The fisrt pulse generally used in normal circumstances and the second pulse used in relatively harsh circumstances First pulse is set as factory default English _9 Terminal Block Detecting Range e 12V DC ANODE e GND DC CATHODE e ALARM RELAY OUTPUT PORT e

Download Pdf Manuals

image

Related Search

Related Contents

Polaroid PDC 3000 Digital Camera User Manual  Toshiba 72MX196 Projection Television User Manual  リリースノート - FAST CORPORATION[株式会社ファースト]  Firmware development and intergration for ALICE TPC  Modelos Scorpion 350 con tecnología de control de emisiones (ECT)  Reference Guide  Software KMG-VD User Manual - gte  LINEAR ACTUATOR  

Copyright © All rights reserved.
Failed to retrieve file