EU5C-SWD-PROFINET UM 07 EN

image

Contents

1. 3a o an j j o j 0 UR 5 F gt In the configuration window the added power module is displayed in the rail 3 Add CPU for IO Controller PLC gt Inthe Hardware Catalog of the HW Config window choose the CPU you are using e g SIMATIC 300 gt CPU 300 gt CPU 315 2 PN DP gt 6ES7 315 2EH13 0AB0 gt V2 6 and drag and drop it onto Slot 2 of the rail in the configuration window SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Commissioning gateway 55 112 On dropping the CPU onto the slot the Properties Ethernet Interface sheet automatically opens _is HW Config SIMATIC 300 1 Station Edit Insert PLC View Options Window Help DESER 3 20 d Baer sir SIMATIC 300 1 Configuration u m 8 UUM foarren Ethernet interface PN IO RO S2 2 fx ant ani IF PS 307 104 ae General Parameters Standard 59 CPU 312C A CPU 313 B If a subnet is selected o CPU 313C the next available addresses are suggested CPU 313C 2 DP C CPU 3130 2 PtP CPU 314 CPU 314 IFM CPU 314C 2 DP CPU 314C 2 PN DP CPU 314C 2 PtP CPU 315 CPU 315 2 DP CPU 315 2 PN DP 5 6E57 315 2EG10 0480 5 GES 315 2EH13 0480 g v23 Delete u 9 6E57 315 2EH14 0480 H CPU 315F 2 DP m OA COM MeO DANO Cancel Heb Fre veni3nep0 work
2. SmartWire DT Alarm D Gateway Controller i on on cre Diag Slot OfFail Safe_ ail Figure 56 Diagnosis Alarms Alarms can be process alarms PA or diagnosis alarms DA Process alarms are not issued by the gateway Diagnosis alarms can be e Return of submodule alarm e Pull alarm e Plug alarm e Diagnosis Return of submodule alarm Alarm issued for every plugged SmartWire DT slave when SmartWire DT returns from fail safe back to run normal state Pull alarm Removal pulling or failure of a slave in the SmartWire DT network leads to a pull alarm in PROFINET IO SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public PROFINET IO data communication 93 112 Plug alarm Adding plugging or reinstalling a slave in the SmartWire DT network leads to a plug alarm only if the concerned slave device is included in the target configuration Adding a slave which is not included in the target configuration will not cause an alarm Note gt After having added a new slave device to the SmartWire DT network you need to disconnect the PROFINET IO from the gateway and read in the new target configuration of the SmartWire DT network see section Einlesen der SmartWire DT Konfiguration page 44 Please note that you also need to add the new slave to the PROFINET IO configuration Diagnosis Diagnosis data issued b
3. Figure 32 Set PG PC Interface 1 gt Inthe Interface Parameter Assignment Used list of the Access Path tab select the network interface card you are using on your programming device PC gt Click Properties button SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Commissioning gateway 71 112 gt The Properties sheet for the selected network interface card opens Properties TCP IP Auto gt Intel R 82566DM 2 Gig TCP IP network IE PG Access Details The IP addresses described here are needed by STEP 7 if the node is in a different subnetwork than the local IP address of the programming device STEP 7 creates additional IP addresses on the local programming device PC for this purpose C Do not assign IP addresses automatically IP address Network address First IP address Last Delete project specific IP addresses Cancel Help Figure 33 Set PG PC Interface 2 gt Inthe IE PG Access tab select Assign IP addresses unique to the project option then click OK button dv You are back in the Set PG PC Interface dialog box gt Click OK button to take over the setting of the PG PC interface 2 Load configuration to S7 300 PLC gt Open the HW Config window for the Project gt Inthe menu bar of the HW Config window select PLC gt Download The Select Target Module dialog box opens Select
4. e Connect only ports with each other which have different cross over settings Otherwise a connection between the devices cannot be established If the port settings of the PROFINET IO Controller are not set to AUTO then PortO is switched uncrossed and Port1 crossed SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Installing gateway 42 112 7 6 EMC Conformant Wiring of the Network Undesired faults can occur on the bus due to electromagnetic interference This can be minimized beforehand by the implementation of suitable EMC measures These include e EMC conformant system configuration e EMC compliant cable routing e Measures that do not allow the occurrence of large differences in potential and e correct installation of the PROFINET system cables connection of the bus connectors etc The effects of electromagnetic interference can be significantly reduced by fitting a shield For detailed information on this please refer to the PROFINET BA Installation Guideline for Cabling and Assembly published by the PROFIBUS Nutzerorganisation e V Order No 8 072 SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Commissioning gateway 43 112 8 Commissioning gateway Before switching on check whether the power supply for the gateway is connected co
5. 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Commissioning gateway 75 112 gt The Properties sheet of the data block opens Properties Data Block General Part 1 General Part 2 Calls Attributes Name and type DBI od Shared DB v Symbolic Name Symbol Comment Created in Language DB Project path St locati of pears aol C ProgrammeSiemens Step s proj S martwir Code Interface Date created 04 23 2012 11 04 31 AM Last modified 04 23 2012 11 04 31 AM 04 23 2012 11 04 31 AM Comment Cancel Help Figure 39 Create Data Block gt Inthe Name and type field of the General Part 1 tab enter the name of the data block e g DB100 then click OK button gt The new data block is displayed in the Blocks node of the project window SmartWire project C Programme Siemens Step s 7 proj SmartWir p a System data io 061 SIMATIC 300 1 CPU 315 2 PN DP E 57 Program Sources cy Blocks Figure 40 Data Block Created 2 Edit data block gt Select DB100 block gt Double click DB100 block or choose Edit gt Open Object in the menu bar SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Commissioning gateway 76 112 gt The data block is opened in the editor RA AD STL FBD DB100 File Edit Insert PLC Debug Yiew Options Win
6. Figure 36 Select Node Address 2 gt Inthe Accessible Nodes list select the row featuring the MAC address of the CPU then click OK button SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Commissioning gateway 73 112 gt If no IP address has been assigned to the CPU before the following Download message appears Download 288 81 The selected node does not have a IP address yet Do you want to assign the address 10 11 12 1 now Figure 37 Select Node Address 3 gt Answer the question whether the IP address should be assigned with Yes dv The IP address is assigned to the CPU and the configuration is loaded to the CPU of the PLC gt Inthe menu bar of the HW Config window choose Station gt Exit to close HW Config Answer the save prompt with Yes SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Commissioning gateway 74 112 8 3 4 Step by Step Instructions for Programming in STEP 7 Display I O Data The following step by step instructions provide a simple programming example for a PLC in STEP 7 It shows how to monitor I O data of the M22 SWD K22LED B function element which is a SmartWire DT slave controlled by a S7 300 PLC via the EU5C SWD PROFINET Gateway For this you must first define a data block and an organiza
7. Released Public Commissioning gateway 49 112 8 3 2 Step by step instructions for configuring gateway with STEP 7 8 3 2 1 Create project in STEP 7 1 Start STEP 7 SIMATIC Manager gt Inthe Windows Startmenu choose All Programs gt SIMATIC gt SIMATIC Manager dv The SIMATIC Manager opens gt Ifthe STEP 7 Wizard New Project appears close the wizard by clicking the Cancelbutton 2 Create new project gt Inthe menu choose File gt New The New Project dialog box opens K SIMATIC Manager File PLC View Options Window Help D SP ax Yy oe New Project User projects Libraries Multiprojects Name Storagepath oo C ProgrammeSiemens Step s Add to current multiproject Name Type Smartwire project Project F FE Library Storage location path c Programme Siemens Step s proj Browse Cancel Help G Press F1 to get Help TCP IP Auto gt Intel R 82566DM 2 Gik A Figure 7 Create new project in SIMATIC Manager gt Inthe User projects tab use the Namefield to enter the name of your project In the Typedrop down list select Projectentry gt Click OK button gt The New Project dialog box closes and a window containing the new project opens 3 Add PLC to the project gt Inthe project tree of the project window in the left part of the project window select your new project In the menu bar choose Insert gt Station gt SIMATIC
8. gt page 41 Commission gateway Chapter Commissioning gateway gt page 43 Configure SmartWire DT network in gateway Section Configuring SmartWire DT network in gateway page 43 Configure a PROFINET IO project for gateway Section Configuring gateway in PROFINET IO network page 46 2 1 Import GSDML device description file in Section GSDML device description file gt page 46 programming tool Example for STEP 7 Section Import GSDML device description file gt page 51 2 2 Configure gateway in PROFINET IO project Example for STEP 7 Section Step by step instructions for configuring gateway with STEP 7 page 49 Load PROFINET IO configuration to Controller Example for STEP 7 Section Step by step instructions for PLC loading PROFINET IO configuration to S7 300 PLC gt page 70 3 Program Controller PLC Example for STEP 7 Section Step by Step Instructions for Programming in STEP 7 Display I O Data gt page 74 Table 18 Getting Started SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Installing gateway 34 112 Installing gateway 7 1 Safety messages ore Electrical shock Please observe the following safety messages when you install and handle the gateway gt First disconnect the power plug of the device gt Make sure that the power supply is off at the device gt Cover or enclose neighboring units that a
9. oe hilscher COMPETENCE IN COMMUNICATION User Manual SmartWire DT Gateway EU5C SWD PROFINET Hilscher Gesellschaft f r Systemautomation mbH www hilscher com DOC120304UMOTEN Revision 7 English 2015 06 Released Public Table of contents 2 112 Table of contents 1 WPVCRO GUC HOW ive saccn teaser nun nee nen E eateetausqucessnccessuanccecnstanpecswscevuede seeeeue 5 1 1 About this GO GUIME NE ssspiciesisepnnscarsire dunn en een ee 5 1 1 1 Description of the contents 2 20022002200220snnennnennnennnennnn nenn nenn nenn nenn nenn nennen 5 1 1 2 LISCO FSV IS ONS ooi EE E E AO T NE A N 5 1 1 3 Conventions in this document uud 6 1 2 Versions of devices firmware software drivers and device description file T t3 Sotware Ors 6 0 ee er en ene eer E ee eet engeren 8 1 3 1 Oe aN OW ena ee E EA en ee een ee eens 8 1 3 2 Contents of the product DVD s nesnsensnnsnnonnsnrorrenrsrrerrsrrerrerrerrerrerrerrsrrrrrrrrerne 8 1 3 3 How TO use the product DVD une an arena 10 1 3 4 Notes on installing the USB Driver ccccccceccecseeceeeeeeeeeseeeseeeeseeeesaeesaneeees 11 1 4 DOCUMENTATION overview cccceccceecc ccc ceseeceeceecceeeseeseeceusteeteeessecseeseeseeesseteeeaueteeeseesaes 12 1 9 MA DOES ee ee ee ee 13 1 5 1 COPY IE ne sn ee ea ana ee er ne Deere 13 1 5 2 Important notes 2002402200240200nnnonnonnnnnnnnnennnnnnennennnnnnnnnnnnennn
10. 9 CPU 313 CPU 313C 9 CPU 3130 2 DP GI CPU 3130 2 PIP CPU 314 C CPU 314 IFM E CPU 3140 2 DP C CPU 314C 2 PN DP CPU 314C 2 PIP CPU 315 9 CPU 315 2 DP GI CPU 315 2 PN DP 9 6657 315 2EG10 04B0 6E57 315 2EH13 04B0 E i N H 0 BES 315 2EH14 OABO CPU 315F 2 DP m Fa COI RC 9 Dal IND A Communication loadable FBs FCs y cho 4 Hilscher 2012 2015 Commissioning gateway 59 112 8 3 2 5 Configure gateway in PROFINET IO 1 Add gateway gt Inthe Hardware Catalog under PROFINET IO gt Additional Field Devices gt Gateway gt EU5C SWD select the EU5C SWD PROFINET object and drag it into the configuration window then drop it below the PROFINET bus line which you have added in the previous step dv In the configuration window the PROFINET bus line is depicted with the connected gateway fit HW Config SIMATIC 300 1 EIER Station Edit Insert PLC View Options Window Help DESE amp Se dod MO Ww By x fil SIMATIC 300 1 Configuration SmartWire project Sele Find at ail Profile Standard v J Ps 307 104 S PROFIBUS DP CPU 315 2 PN DP S PROFIBUS PA M PROFINET I0 Additional Field Devices 9 Gateway 5 EUSC SWD u ESS Eaton H Q Partner devices Wo ne __Ethernet 1 PROFINET IO System 100 G HM 170 Network Components
11. Available in various lengths Press Fi to get Help cho 4 Figure 13 Added Rail The rail is displayed in the configuration window 2 Add power supply module for IO Controller PLC gt Inthe Hardware Catalog of the HW Config window under SIMATIC 300 gt PS 300 choose the appropriate power module e g PS 307 10A and drag and drop it onto Slot 1 of the rail in the configuration window Note gt Once you have selected an object in the hardware catalog all slots in the configuration window onto which the object can be dropped are highlighted in a green color This helps you to find the right slot SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Commissioning gateway 54 112 Gi HW Config SIMATIC 300 1 Er ER Station Edit Insert PLC View Options Window Help De Se do MO ww x i SIMATIC 300 1 Configuration SmartWire project Eu m Ind at ail DJ UR Profle Standard lg PS 307 104 CI HMI amp 0 C Network Components E Sensors 9 Switching devices SIMATIC 300 gy C7 CP 300 C CPU 300 GI FM 300 I Gateway G IM 300 M7 EXTENSION PS 300 PS 307 104 PS 307 104 PS 307 104 PS 307 24 PS 307 24 PS 307 54 DC INF BA BES 307 1K 401 0440 Load supply voltage 120 230 VAC 24 YDC 10 A Press Fi to get Help Ch 4 Figure 14 Added Power Module
12. Backup FW Device Reset Device Reset The device was reset successfully All connections are closed You should be able to reconnect in a few seconds Figure 63 Successful device reset message as depicted in Internet Explorer gt The POW system status LED at the gateway shows steady yellow light The new firmware has been loaded and the gateway is ready for operation SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UM07EN Revision 7 English 2015 06 Released Public Technical data 105 112 12 Technical data 12 1 Technical data EUSC SWD PROFINET gateway Parameter W x H x D i Standards IEC EN 61131 2 Communication controller netX 50 processor Diagnostic interface Mini USB Integrated memory 8 MB SDRAM 4 MB serial Flash EPROM Protection type IP20 IEC EN 60529 EN50178 VBG 4 Vibrations Constant amplitude 3 5 mm 5 9 Hz IEC EN 61131 2 2008 Constant acceleration 1 g 9 150 Hz Mechanical shock resistance Semi sinusoidal 15 g 11 ms 9 Shocks IEC EN 60068 2 27 Drop to Drop height 50 mm IEC EN 60068 2 31 Free fall packaged Drop height 1 m IEC EN 60068 2 32 Ambient climatic conditions Operating ambient temperature 25 55 C IEC 60068 2 Condensation Prevent by suitable measures Storage 40 70 C Relative humidity non condensing 5 95 IEC EN 60068 2 30 Pollution degree Ambient mechanical D a c
13. Click Close button to leave the Edit Ethernet Node dialog box b Important Please note that you also have to change the parameters in the PROFINET IO configuration accordingly and that you have to load the adjusted configuration to the S7 300 PLC SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public PROFINET IO data communication 88 112 9 PROFINET IO data communication 9 1 9 1 1 Acyclical communication Address mapping For acyclic communication the read write record services of the PROFINET IO controller are in the EU5C SWD PROFINET Gateway converted to SmartWire DT read write services and forwarded to the SmartWire DT slaves An address mapping enables the PROFINET IO Controller to access the SmartWire DT slaves via the gateway The following figure depicts the mapping of the PROFINET IO slot subslot and index to SmartWire DT slave and index SmartWire DT Slave 1 99 Acyclic Communication LLN Name of Station Gateway Slot 1 99 Figure 54 Acyclic data address mapping The gateway is addressed by the PROFINET IO name of station This makes is possible to address devices in the PROFINET IO network The numbering of the slots corresponds to the sequence of the SmartWire DT slaves i e Slot 1 is assigned to the first slave etc The Subslot in PROFINET IO and in SmartWire DT is always 1
14. Device type label EU5C SWD PROFINET anannonnonnonnsnnennsnnsrnsnrnrnsrnrrrerrsrrnrrsrererene 32 Gening Stared secerneren EOE EAEE OEE EAEE 33 Baas esc EA en nn eier 45 APE 1 D enne E N E E ES 47 OT LED ee sere ee Be an Eee een 47 Application parameters of gateway uesuuesseesseesnessnennnennnnnnnnnnnnnnnn nenn nenn nenn nenn nennen 64 Application parameters of slave us2usssuenseesnennnennnennnnnnnnnnnnnnnnnnnennnennnenenenen 69 Acyclic data error codes for read requesis 202220222002s0snnnnnnnnnnennnennne nenn nennen 90 Acyclic data error codes for write requests cccceccceeeceeececeeeeceeeceeeeeeeeseeeeeaaes 91 Diagnosis p lamelerS ea ee ee ee en on nad 93 Diagnosis ChannelErrorType na 94 Controls in firmware update page ccceccceccceeceeeeeeeeeeeceneeeeeeseesseeeneteeeeeeteeeeeeees 97 Technical data EU5C SWD PROFINET gateway cccccccccecceeeeeseeeseeeeeeeeseeees 105 Technical data PROFINET IO RT Device protocol cccccccceeeceeeeeeeeeeeteeeeeeeees 108 Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Contacts Contacts HEADQUARTERS Germany Hilscher Gesellschaft fur Systemautomation mbH Rheinstrasse 15 D 65795 Hattersheim Phone 49 0 6190 9907 0 Fax 49 0 6190 9907 50 E Mail info hilscher com Support Phone 49 0 6190 9907 99 E Mail de support hilscher com SUBSIDIARIES C
15. Ethernet interface PN IO RO S2 2 Ri ati 4 Ps 307 104 Parameters Standard f cPu 3is 2pnpp_ ei CPU 312C a Memo amp CPU 313 da Pr If a subnet is selected CPU 313C AA the next available addresses are suggested CPU 313C 2 DP En CPU 3130 2 PiP CPU 314 Gateway H CPU 314 IFM IP address Innen Do not use router CPU 314C 2 DP Subnet mask 255 255 255 0 Ga CPU 314C 2 PN DP C Use router a CPU 314C 2 PtP Address CPU 315 CPU 315 2 DP J Subnet I CPU 315 2 PN DP not networked ie 6E57 315 2EG10 04B0 3 6E57 315 2EH13 0480 v2 3 g v25 Delete V26 H 0 6ES7 315 2EH14 0AB0 CPU 315F 2 DP m Fa COI HRC DaIND a _ Caneel Helo Fis 2eH13 0880 at work memory 0 1 ms 1000 instructions PROFINET connection 57 Communication loadable FBs FCs v cho 4 Press Fi to get Help Figure 17 Add PROFINET IO 1 2 Set parameters for PROFINET IO network gt Ifinecessary change the values of the IP address and the Subnet mask in the Parameters tab gt Inthe Parameters tab click New button SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Commissioning gateway 98 112 gt The Properties New subnet Industrial Ethernet sheet opens Properties New subnet Industrial Ethernet General
16. Name 57 subnet ID 0040 0004 Project path Storage location gt of the project Ic Programme Siemens Step s proj S martwir Author Date created 04 20 2012 03 56 01 PM Last modified 04 20 2012 03 56 01 PM Comment Cancel Help Figure 18 Add PROFINET IO 2 gt Inthe Name field of the Properties New subnet Industrial Ethernet sheet enter a new name for the network or accept the preset default name Then click OK button You are back in the Properties Ethernet Interface sheet Yy In the Properties Ethernet Interface sheet click OK button gt The Properties Ethernet Interface sheet is closed and in the configuration window the newly added PROFINET IO network is depicted as PROFINET bus line ti HW Config SIMATIC 300 1 Station Edit Insert PLC View Options Window Help meak DERSE BS oe ud MO wey WI SIMATIC 300 1 Configuration SmartWire project 4 PS 307 104 8 CPU 315 2 PN DP __Ethernet 1 PROFINET IO System 100 Order number Firmware MPI address address O address Comment i PS 307 104 BES 07 KA 2 CPU 315 2 PN DP GES7 315 2EH13 OAB V2 6 O2 47 7 4 MADE as ae es Ca ee Press Fi to get Help Figure 19 Added PROFINET IO network SmartWire DT Gateway EU5C SWD PROFINET DOC120304UMOTEN Revision 7 English 2015 06 Released Public BY x Find ant ail Profile Standard fag CPU 312C
17. Press F1 to get Help Profile Standard v ASE PROFIBUS DP 38 PROFIBUS PA 38 PROFINET IO Ethemet 1 PROFINET IO System 100 Additional Field Devices u sa aa aaa Gateway 3 EUSC SwD gall eusc w jm EUSC SWD PROFINET a J Eaton LJ ee Input Output modules 3 EUSE SWD 2424 EUSE SWD 44 EUSE SWD 4D2R EUSE SWD 4D4D EUSE SWD 4DX EUSE SWD 4PT EUSE SWD BDX EUSE SWD X8D Modules for switchgear Comment 7 8 J Other elements P Pilot devices artner devices lt IT Hilscher GmbH 2 analogue inputs and 2 analogue outputs GSDML 2 2 Hilscher EU5C SWD 201 20404 xml Figure 27 Added SmartWire DT slave gt Add other SmartWire DT slaves as necessary Proceed as described above If you are not sure about the final SmartWire DT topology and perhaps wish to add SmartWire DT slaves later you can add a placeholder For further information see section Adding SmartWire DT Slaves later gt page 82 SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UM07EN Revision 7 English 2015 06 Released Public Commissioning gateway 66 112 Important gt Observe the correct order of the SmartWire DT slaves in the SmartWire DT network The SmartWire DT slaves must be configured in PROFINET IO in the exact order according to their arrangement in the installation gt The universal module is not a valid SmartWire DT slave and must not be added t
18. RK TX LINK RX TX 9 24V 0 OV EU5C SWD PROFINET POW System status APL Application status Config Configuration status SWD SmartWire DT status SF PROFINET IO system error BF PROFINET IO bus error LINK for channel 0 Receive Transmit RX TX for channel 0 LINK for channel 1 Receive Transmit RX TX for channel 1 Table 13 LEDs EUSC SWD PROFINET gateway SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Device picture connectors and LEDs 29 112 5 2 2 Descriptions of the LEDs o eoo State meaning O O OoOO POW Duo LED yellow green System status el Firmware and operating system are running Number in 286 80 picture 38238 Flashing green Second Stage Bootloader is not able to load firmware The device needs to be sent in for servicing 1 green yellow green On Backup firmware is active The gateway needs a firmware recovery as described in chapter Firmware recovery via HTTP gt page 100 W green Flashing green ROM loader is not able to find bootable image The device needs to be sent in for servicing Con fF Power supply for device is missing or hardware defect APLApplication en status The communication on PROFINET and SmartWire DT is in cyclic data green Number in exchange and the gateway function is executed picture 2 W Flashing 2 s Gateway
19. Sensors Switching devices e 1 eu5Sc swd profinet Slot Jf Module Order number address O address Diagnostic address Comment n P a eude swetprofinet PNEK SW SIMATIC 300 JAN a a a ag SIMATIC 400 3 x 5 i 2 0 a er oer oer Cy IMATIC PC Based Control 300 400 SIMATIC PC Station PNPx S w Er Hilscher GmbH an Profinet AT SmartwireDT Gateway GSDML V2 2 Hilscher EU5C SWD En 20404 xml Insertion possible Chg 4 Figure 20 Added gateway 2 Set device name of gateway in PROFINET IO network gt Inthe upper part of the configuration window double click the gateway symbol SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Commissioning gateway 60 112 gt The Properties sheet of the gateway opens Properties eubc swd profinet General Identification Short description eubc swd profinet Profinet AT SmartwireDT Gateway Order No firmware PNPx SW D x Family EUSC SWD Device name GSD file GSDML V2 2Hilscher EUSC SWD 20120404 xml Change Release Number Node in PROFINET I0 System Device number Il PROFINET I0 System 100 IP address 192 168 0 2 Ethernet IV Comment Cancel Help Figure 21 Set device name of gateway In the Device name field of the General tab you see the preset name of the gateway which the STEP 7 software has taken
20. 300 Station SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Commissioning gateway 50 112 gt The PLC is displayed in the project window RJ SIMATIC Manager SmartWire project File Edit Insert PLC View Options Window Help Delna e lo Se Pols EE EB re Ay SR HS P a SmartWire project C Programme Siemens Step s7proj SmartWir Sel 2 Smart wire project SIMATIC 300 1 Press F1 to get Help TCP IP Auto gt Intel R 82566DM 2 Gir h Figure 8 PLC added to the project 4 Open Hardware Configuration gt Inthe project tree select SIMATIC 300 1 symbol then double click Hardwaresymbol in the right part of the project window gt The HW Config Hardware Configuration window for the project opens Gis HW Config SIMATIC 300 1 Sele Station Edit Insert PLC View Options Window Help DSE R 4 oe da MO Bw o x RII SIMATIC 300 1 Configuration SmartWire project x Find ant ani Profile Standard ASE PROFIBUS DP AS PROFIBUS PA SS PROFINET I0 SIMATIC 300 SIMATIC 400 SIMATIC PC Based Control 300 400 B SIMATIC PC Station u SIMATIC 300 1 PROFIBUS DP slaves for SIMATIC 57 M7 and C distributed rack Press Fi to get Help Figure 9 Hardware Configuration Window SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 Englis
21. 38 112 7 3 Connecting gateway to power supply A amp A DANGER Danger of lethal injuries by unexpected starting up of motors or machinery If you have already integrated devices into a system secure the operating range of any connected parts of the system against access so that nobody is endangered by motors or machinery starting up unexpectedly Danger of unsafe operation of the system In safety relevant applications the power supply providing power for the SmartWire DT system must feature a PELV power feed module protective extra low voltage Danger of unsafe operation of the system You must take safety precautions emergency switching off in the external circuitry of the gateway and any power modules type EU5C SWD PF 1 1 or EU5C SWDPF2 1 that are used To do so plan to switch off the power supply to the contactor coils AUX Important Please take into consideration the total power consumption of your SmartWire DT network and if necessary plan for an additional feeder module EU5C SWD PF2 You can find information on the power consumption in the operating manuals of the SmartWire DT devices gt Connect the 24 V DC voltage to the POW terminals on the front side of the gateway The POW connection provides the voltage for the gateway itself and for the SmartWire DT slave electronics Note gt For the 15 V supply of the SmartWire DT slaves the gateway contains an additional power feed module with an amperag
22. DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Commissioning gateway 65 112 8 3 2 6 Configure SmartWire DT slaves in PROFINET IO 1 Add SmartWire DT slaves Note gt If you are using a project specific GSDML device description file M FR HW Config SIMATIC 300 1 which was created by the SWD Assist software and which contains preconfigured SmartWire DT slaves you don t need to add and configure SmartWire DT slaves as described in the subsequent section For information on project specific GSDML files created with SWD Assist please refer to the SWD Assist online help In the configuration window select the gateway symbol In the Hardware Catalog select under PROFINET IO gt Additional Field Devices gt Gateway gt EU5C SWD gt EU5C SWD PROFINET gt Eaton a slave device of your SmartWire DT network e g EU5E SWD 2A2Ain the Input Output modules folder then drag it into the lower part of the configuration window and drop it onto an appropriate slot of the gateway e g Slot 1 Slots onto which the device can be dropped are highlighted in green color In the lower part of the configuration window the added SmartWire DT slave is displayed in the assigned gateway slot Station Edit Insert PLC View Options Window Help DSE HS ae dae Ho Rw fil SIMATIC 300 1 Configuration SmartWire project la PS 307 104 8 CPU 315 2 PN DP
23. DT interface plug 8 pole a 2 port switch Ethernet interface RJ45 for connecting PROFINET and a Mini USB interface Via the Mini USB interface the gateway can communicate with the SWD Assist software 3 4 Diagnosis The gateway can be diagnosed by connecting the SWD Assist software to the Mini USB interface For further information please refer to the SWD Assist online help The PROFINET IO protocol also provides diagnostic functions For further information see section Alarms and diagnosis controlled by the gateway page 92 3 5 Updating firmware and device description file The EU5C SWD PROFINET gateway is shipped with its most recent firmware already loaded Note gt If your gateway is running with a firmware version older than 1 4 x x it is strongly recommended to update the firmware and to use the version of the device description file specified in section Bezug auf Ger te Firmware Software Treiber und Ger tebeschreibungsdatei page 7 Since version 1 4 x x the version of the firmware which has been loaded in the gateway before delivery can be inferred from the device type label attached to the gateway You can update the firmware from your configuration PC by using an ordinary web browser A web server embedded in the gateway which can be accessed via its Ethernet interface provides a special web page for updating the firmware For more details on this please refer to chapter Updating firmware
24. Edit Insert PLC View Options Window Help DESER Be dod MO Ww BI x WII SIMATIC 300 1 Configuration SmartWire project Find PO at ajl Profile Standard v PROFIBUS DP TE PROFIBUS PA SS PROFINET I0 Additional Field Devices Gateway EUSC SWD Gm EUSC SWD PROFINET 9 Eaton w Partner devices 4 PS 307 104 8 CPU 315 2 PN DP __Ethernet 1 PROFINET IO System 100 SmartWire a 1 0 Gateway HMI 1 0 1 euSc swd profinet Network Components Sensors Slot 4 Module Order number address OQ address Diagnostic address Br Comment J Switching devices 4 m eude swihprefinet PRFX SW PL 17 Ko A l SIMATIC 300 i ings Sma a SIMATIC 400 A SIMATIC PC Based Control 300 400 8 SIMATIC PC Station 4 Profinet RT SmartwireDT Gateway GSDML 2 2 Hilscher EU5C SWD So 20404 xml Press Fi to get Help cho 4 Figure 23 Set further gateway parameters 1 gt The Properties sheet opens Note gt The gateway has two different Property sheets in STEP 7 One opens if you double click on the gateway symbol position 1 in the upper part of the configuration window the other opens if you double click the gateway entry on Slot 0 position 2 in the lower part of the configuration window In the General tab you can enter a comment Properties eu5c swd profinet R SO General Addresses Parameters
25. Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Requirements for operation 26 112 4 2 1 POW power connection A Power supply of 24 V DC for the coupling unit and for the Smart Wire DT slave electronics is needed at the connection POW On the SmartWire DT gateway connect the POW and AUX supply voltages via separate miniature circuit breakers or fuses Miniature circuit breaker 24 V DC for POW e Cable protection in accordance with DIN VDE 0641 Part 11 IEC EN 60898 Miniature circuit breaker 24 V DC rated operational current 3 A trip types Cor Fuse 3A utilization class gL gG e Cable protection for cable AWG 24 in accordance with UL 508 und CSA 22 2 No 14 Miniature circuit breaker 24 V DC rated operational current 3 A Tripping characteristics C or Fuse 3A 4 2 2 AUX power connection If any switching devices are also to be connected for example via the DIL SWD 32 001 002 SmartWire DT slaves a 24 V DC supply will also be required at the AUX power connection This provides the supply for activating the contactor coils This supply must be protected by an automatic circuit breaker 3A gG gl or 3 A miniature circuit breaker with a Z characteristic If switching devices with an activation power greater than 3 A are connected an additional feeder module EU5C SWD PF1 or EU5C SWD PF2 must be used On the SmartWire DT gateway connect the POW and AUX supply voltages via separate miniatu
26. Short description euSc swd profinet Profinet AT SmartwireDT Gateway Order no Hardware revision level Software revision level Name Comment Cancel Help Figure 24 Set further gateway parameters 2 SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UM07EN Revision 7 English 2015 06 Released Public Commissioning gateway 63 112 gt Click the Comment field and enter your text After closing the Properties sheet the text will be displayed in the Comment column in the lower part of the configuration window In the Addresses tab you can accept or change the preset diagnostic address of the gateway Properties eu5c swd profinet R SO General Addresses Parameters Diagnostic Address Diagnostic address EIER Cancel Help Figure 25 Set diagnostic address of gateway gt Click the Diagnostic address field and enter the new address In the Parameters tab you can set the application parameters of the gateway in regard to its function as master in the SmartWire DT network Properties euSc swd profinet R SO General Addresses Parameters SERIES y O HE Master parameter SS E Baudrate Smartwire DT Compatible devices allowed CO E Al slaves optional 2 Delay betw cyclic exchange ms fo oo O Cancel Help Figure 26 Set application parameters of gateway SmartWire DT Gateway EU5C SWD PROFINET Hil
27. The Index is passed on unaltered from SmartWire DT to PROFINET IO The meaning of the indexes depends on the individual SmartWire DT Slaves SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public PROFINET IO data communication 89 112 9 1 2 Error detection and error codes The following figure shows at which points error detection is possible in acyclic communication Error Detection ae Read Write D Controller Read Write DF80A100 Data OK Figure 55 Acyclic data error detection Errors detected in the gateway PROFINET IO device are reported as normal PROFINET IO errors to the controller All errors except addressing errors which are detected on SmartWire DT master or slave are reported with error code OxDE80A000 read or OxDF80A100 write to the PROFINET IO controller Error detection by the gateway for read write records An error code e g OxDE80BO00 consists of an ErrorCode DE IODReadRes ErrorDecode 80 PNIORW ErrorCode1 BO invalid index and ErrorCode2 00 not defined SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public PROFINET IO data communication 90 112 Error codes for read requests All error messages supported by the gateway concerning read requests start with ErrorCode DE IODReadRes negative resp
28. correctness or accuracy of the information is assumed We reserve the right to change our products and their specification as well as related user manuals accompanying texts and documentation at all times and without advance notice without obligation to report the change Changes will be included in future manuals and do not constitute any obligations There is no entitlement to revisions of delivered documents The manual delivered with the product applies Hilscher Gesellschaft f r Systemautomation mbH is not liable under any circumstances for direct indirect incidental or follow on damage or loss of earnings resulting from the use of the information contained in this publication SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMO7EN Revision 7 English 2015 06 Released Public Introduction 14 112 1 2029 Exclusion of liability The software was produced and tested with utmost care by Hilscher Gesellschaft fur Systemautomation mbH and is made available as is No warranty can be assumed for the performance and flawlessness of the software for all usage conditions and cases and for the results produced when utilized by the user Liability for any damages that may result from the use of the hardware or software or related documents is limited to cases of intent or grossly negligent violation of significant contractual obligations Indemnity claims for the violation of significant contractual obligatio
29. displayed in the Status value column Er Sele Table Edit Insert PLC Variable View Options Window Help Dell a see x El Gfarm S Seles M22 SWD SIMATIC 300 1 1 457 Programm S lt gt RO fabs 52 L Figure 48 Monitor Input Data If an event is triggered at the SmartWire DT slave the Status value of the DB100 DBB O element which represents the input data changes gt Push one of the buttons of the M22 SWD K22LED B slave device SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Commissioning gateway 81 112 The corresponding Bit in the Status value column changes from 0 to 1 Information on the assignment of certain Bits to certain operational states and other parameters needed for programming SmartWire DT slaves can be found in the corresponding user manual of the device e g in the Eaton user manual SmartWire DT Units MNO5006001Z EN If the Modify value of the DB100 DBB 1 element which represents the output data is changed an event at the SmartWire DT slave can be triggered gt Inthe variable table change the last Bit of the Modify value of the DB100 DBB 1 element from 0 to 1 Ri Table Edit Insert PLC Variable View Options Window Help a osla a seel x es 2 mej far ale el 2 Api ipm eaae m DB100 DBB 0 BIN DBt 00 DBB 1 BIN M22 SWDISIMATIC 300 1 57 Programmi5 gt
30. gt page 95 In case of a missing or defective firmware a firmware recovery process is possible via HTTP Please refer to chapter Firmware recovery via HTTP page 100 SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Description of the EU5C SWD PROFINET gateway 24 112 Device description files GSDML for the gateway are included on the product DVD in the EDS EU5C SWD PROFINET Vx x x x folder As an alternative you can download the latest versions of the GSDML files from our website www hilscher com under Products gt Partner Products gt SmartWire DT gt EU5C SWD PROFINET gt Downloads Important Q Versions of firmware and device description files functionally belong together This means that after having updated the firmware to version 1 4 x x you also need to replace the old version of the GSDML file GSDML V2 25 Hilscher EU5C SWD 201206XX xml with the new version of the GSDML file GSDML V2 2 Hilscher EUSC SWD XXXXXXXX xml This applies also the other way round If you intend to use the new GSDML file GSDML V2 2 Hilscher EU5C SWD XXXXXXXX xml you need to update the old version of the firmware 1 0 x x to the new version of the firmware 1 4 x x SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Requirements for operation 25 112 4 R
31. is initialized but the communication on PROFINET is not in aS green off 0 5 s on cyclic data exchange Flashing 2 s Gateway is initialized but the communication on SmartWire DT is not off 0 5 s on in cyclic data exchange 0 5 s off 0 5 s Gateway is initialized but the configuration for the communication protocol on PROFINET is missing or in error Flashing 2 s Gateway is initialized but the configuration for the communication off 0 5 s on protocol on SmartWire DT is missing or in error 0 5 s off 0 5 s Gateway has detected an error during the initialization Missing configuration error in configuration or internal error Config Duo LED Configuration The planned configuration complies with the gateway target status configuration Data exchange between Gateway and PLC via Number in PROFINET takes place picture 3 W The planned configuration does not comply with the gateway target configuration but is compatible with it Data exchange between gateway and PLC via PROFINET takes place The planned configuration and the gateway target configuration are not compatible Nodata exchange between gateway and PLC via PROFINET off Off No communication with the PROFINET IO controller or the gateway does not contain a project configuration Table 14 Descriptions of the LEDs SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMO7EN Revision 7 English 2015 06 Released
32. lla Sw xD FH HOLD tHe a a G w OB1 SmartWire project SIMATIC 300 1 CPU 315 2 PN DP BO New network FB blocks FC blocks 3 SFE blocks H SFC blocks M Multiple instances Libraries 4B Interface 4 TEMP DB100 DBB PAB 256 PEB 256 DB100 DBB a Ei Program e KIKI O Cl 2 Info 3 Cross references 4 Address info 5 Modify Press Fi to get Help offline Abs lt 5 2 Nwi Ln5 Insert Chg A Figure 42 Edit Organization Block gt Link the elements representing the input and output data of the SmartWire DT slave i e DB100 DBB 1 and DB100 DBB 0 which you have defined in the data block to the I O addresses which were assigned to the SmartWire DT slave when the project was being configured in PROFINET IO See section SmartWire DT Teilnehmer in PROFINET IO konfigurieren gt page 65 If for example the value 256 was configured as I O address you must enter the programming code as shown in the picture above gt After you have entered the code choose File gt Save in the menu bar of the editor then close the editor SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Commissioning gateway 78 112 4 Load blocks to S7 300 PLC gt Note gt Before you can use a variable table to monitor input and output data of the SmartWire DT slave you must download the code blocks to the PLC gt I
33. low voltage for the 24 volt supply Only use power supply units complying with IEC 60364 4 41 VDE 0100 Part 410 or HD 384 4 41 S2 The allowed range for the supply voltage is indicated in section Technical data EU5SC SWD PROFINET gateway gt page 105 SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Safety 19 112 2 6 3 Electrostatic sensitive device The gateway is sensitive to electrostatic discharge which can cause internal damage and affect its normal operation Therefore adhere to the necessary safety precautions for components that are vulnerable to electrostatic discharge when you install or remove the gateway Follow the guidelines listed hereafter when you handle the gateway e Touch a grounded object to discharge potential static before you handle the gateway e Wear an approved grounding wrist strap e f possible use a static safe workstation e When not in use store the device in appropriate static safe packaging SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Safety 20 112 2 Labeling of safety messages In this document the safety instructions and property damage messages are designed according both to the internationally used safety conventions as well as to the ANSI Z535 standard e The Section Safety Messages at the beginning of
34. of the configuration button see section Device picture gt page 27 All SmartWire DT slaves are re addressed in ascending order in the process This process may only take place in the case of e initial commissioning e the replacement of a defective slave or e achange to the configuration Hazard of device damage by disruption of voltage supply while creating target configuration Do not interrupt the voltage supply while creating the target configuration of the gateway Power failure during a writing process in the file system can Cause severe malfunctioning of the device SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UM07EN Revision 7 English 2015 06 Released Public Commissioning gateway 44 112 If a SmartWire DT slave has failed the SmartWire DT network can still be operated with the remaining slaves depending on the configuration setting even after a repeat power up of the gateway The failure is reported to the application Important If there is a faulty configuration and the configuration button is pressed only the slaves up to the failed device are addressed and stored Use of the remaining slaves is not possible until the defective slave has been replaced and the configuration has been read in again by pressing the configuration button 8 1 1 Reading the SmartWire DT configuration If you startup the gateway for the first time or if you have replaced a SmartWire DT
35. reference to the required slave is implemented with these function blocks via the parameters ID and Index For further information on handling these function blocks please BA refer to the STEP 7 documentation The address of the SmartWire DT slave with which communication is to be established is set at the parameter ID The Index parameter addresses the V1 object The first object is assigned number 1 the second 2 etc On the SmartWire DT slave PKE SWD 32 the object 1 supplies the current value I rel For further information on acyclical data communication see section Azyklische Kommunikation gt page 88 6 3 7 Using STEP 7 to Assign Device Name or IP Address on the Gateway You can use STEP 7 and your programming device PC to assign to your gateway a new IP address or a new device name independently from the PROFINET IO configuration Prerequisites e The gateway is connected to power supply e The gateway is connected via Ethernet to the programming device PC and the STEP 7 software e If you want to change the IP address of the gateway the gateway must not be in a state of cyclic data exchange with the PROFINET IO controller SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Commissioning gateway 84 112 Step by step instructions gt Open HW Config window for the project gt Inthe menu bar of the HW Config window cho
36. slave or changed the setup of the SmartWire DT network in some other way you have to initiate a reading of the SmartWire DT configuration 8 1 1 1 Prerequisites Prerequisites for reading the configuration are e All SmartWire DT slaves are connected to the SmartWire DT line e The SmartWire DT network is connected to the gateway e The voltage POW is applied to the coupling unit and the power LED POW is on e The voltage AUX is applied if necessary e The SmartWire DT status LEDs of the SmartWire DT slaves are on or are flashing Note gt Disconnect the PROFINET IO network from the gateway by removing the RJ45 plug from the Ethernet interface of the gateway before pressing the configuration button SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Commissioning gateway 45 112 8 1 1 2 Step by step instructions gt Press the configuration button on the gateway for at least two seconds for the position of the configuration button see figure in section Device picture gt page 27 Take care to push the button properly You have to feel and overcome a slight resistance when pushing the button into the gateway otherwise the button won t trigger The SmartWire status LED on the gateway begins to flash orange The SmartWire DT status LEDs on the SmartWire DT slaves also flash All slaves are addressed in sequence the complete config
37. tbs lt 5 2 L Figure 49 Modify Value gt Inthe toolbar of the editor click ur Button gt The LED at the M22 SWD K22LED B slave device lights up SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Commissioning gateway 82 112 8 3 5 Adding SmartWire DT slaves later If you are not sure about the final SmartWire DT topology and may wish to add SmartWire DT slaves later adding a placeholder dummy module in the appropriate position in the SmartWire DT network is recommended This is especially useful in STEP 7 since the HW Config tool does not allow the adding of stations between occupied module locations gt During configuration of the project in the engineering tool position the permanent SmartWire DT slaves in the correct order and add the Reserved stored in the Other elements folder element at the required position FS HW Config SIMATIC 300 1 Sees Station Edit Insert PLC Yiew Options Window Help DESER Te do MO wire Bix ol SIMATIC 300 1 Confi tion SmartWi ject my 1 Configuration martWire projec Find Rn P Profile Standard v 4 PS 307 104 E PROFIBUS DP 4 eu a52 PN DP Se PROFIBUS PA 7 PROFINET I0 ig awo Ethemet 1 PROFINET ID System 100 Additional Field Devices i Pont 7 OE 9 Gateway 5 EUSC SwD gal eusc u jm EUSC SWD PROFINET fern E Eaton Sm
38. 2002220s2snenenennnenennnnnn nennen 82 8 3 6 Acyclical data communication S7 300 PLC 02200220022002enennnenneeneen 83 8 3 7 Using STEP 7 to Assign Device Name or IP Address on the Gateway 83 9 PROFINET IO data communication uus 22002u000 n0nnnnunannnnnnnnnnnnnnnnn nun nnnnnnnnnnnnnnn nun anne 88 9 1 Acyclical communication escsindicasecancidmaencntivnd adaciniesiecinnsawarsintne susie bacalvesielwhcesesieuedbainga dictaesledensecnmsntie 88 9 1 1 Address FINA ING siasii E EAA aa 88 9 1 2 Error detection and error COCGS ccceccceccescceseceeeceeeceeecaeeseeecueecueeceeenseesaes 89 9 2 Alarms and diagnosis controlled by the gateway ccccccseceeeeeeeeeeeeeeeeeeeeeeeeseeeseeeses 92 10 Updating MWANG ee ee en et eee eer een eran rere 95 10 1 OVON ON eiA eE E E EEEE A 95 10 2 Prerequisites een 96 10 3 Step by step instructions for updating firmware ccceecceeeceeeceeeceeeseceseeeteeeeeeeeeeees 97 10 4 TRO SCT JalEWay es nen ee see ee 99 11 Firmware recovery via HTTP sancecccwtancdtaeccnetunseistenstsecevetisinenctsaedaissoueeeneiauddiivesdimasaisiamevusciness 100 11 1 Overview secssascts ccsirostsentie pe srantciestaieietnre eds onscramieineianagbosnalenaidedaasrprscduiiensasansaaniseacinsmddweiuaessdeeanieawveatuasits 100 SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UM07EN Revision 7 English 2015 06 Released Public 11 2 We POROU
39. 2A2A device hei atin can set the following parameters Parameter Value Presence of Device on SWD Device shall be present Data Net Ee to PROFINET takes place only if the SmartWire DT slave is present Device shall not be present Data transfer to PROFINET takes place even if the SmartWire DT slave has failed or is not present Note Parameter setting at this point only makes sense if in the application parameters of the gateway the All slaves optional parameter has been set to Defined for each slave See table Application parameters of gateway in previous section Replacement by universal not allowed The SmartWire DT slave may not be replaced by a module universal module allowed The SmartWire DT slave se be replaced by universal module M22 SWD NOP C Type of sensor input 0 Voltage 0 10V sd Voltage 0 10V sd 10V Defines the type of een the SmartWire DT Current 0 20mA slave is using current or voltage based sensor actuator Type of sensor input 1 Voltage 0 10V Current 0 20mA Type of sensor output 0 Voltage 0 10V Current 0 20mA Type of sensor output 1 Voltage 0 10V Current 0 20mA ss Current 0 20mA ss 20mA Measurement update time u ms 100 ms 200 ms 500 Defines the refresh rate of readings Off Switches averaging on off Table 23 Application parameters of slave gt Click OK button to close the Properties sheet 8 3 2 7 Save and compile configuration After you have finished to configure
40. 3C 2 PIP CPU 314 9 CPU 314 IFM 9 CPU 314C 2 DP CPU 314C 2 PN DP 5 CPU 314C 2 PIP sj CPU 315 9 CPU 315 2 DP Rd Sa 5 CPU 315 2 PN DP Slot fd Module Order number Firmware MPI address address Q address Comment 9 6657 315 2EG10 0AB0 1 fg PS 307104 6E57 307 1KA01 0440 6ES7 315 2EH13 0AB0 2 CPU 315 2 PN DPI6ES7 315 2EH13 OAB V2 6 DO 27 EA U Ee PP AP A ae CS SP EEE 4 E E amp 9 6657 315 2EH14 04B0 9 CPU 315F 2DP m Fa CO FRE ODA NnD Communication loadable FBs FCs Insertion possible er 4 Figure 16 Added CPU SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Commissioning gateway 57 112 8 3 2 4 Configure PROFINET IO network 1 Add PROFINET IO network gt Inthe configuration window right click the X2 PN IO interface then choose Insert PROFINET IO System from the context menu The Properties Ethernet Interface sheet which you have already seen in the previous step when you added the CPU opens again The IP address and the Subnet mask are displayed in the Parameters tab and can be changed here once again Li HW Config SIMATIC 300 1 EX Station Edit Insert PLC View Options Window Help Dae SS Soe dn MO wily em Iwo Stl I SIMATIC 300 1 Configuration 772 gt Properties
41. 5 Scope of Delivery section substituted by Software Package section 3 2012 07 16 Installation program for USB driver added Section Notes on Installing the USB driver added 4 2013 03 28 Section Versions of Devices Firmware Software Tools Drivers and Device Description File updated Section Device Type Label added Section Compatibility of SmartWire DT Devices and Gateway updated Section Updating Firmware and Device Description File revised 5 2013 10 01 References to directory of product DVD updated Device picture updated Section Compatibility of SmartWire DT Devices and Gateway removed from document Obsolete cross reference to removed section Compatibility of SmartWire DT Devices and Gateway deleted Description of POW LED in section Descriptions of the LEDs updated Contacts section updated Safety symbols revised according to ANSI T 2015 06 17 Design of safety messages updated Section Alarms and diagnosis controlled by the gateway gt page 92 updated Table 1 List of revisions 2014 11 05 Chapter Firmware Recovery via HTTP added Section Software Package updated Path for downloading GSDML file in section GSDML Device Description File updated SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMO7EN Revision 7 English 2015 06 Released Public Introduction 6 112 1 1 3 Conventions in this document Notes operation instructions and results of operation steps are marked a
42. C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Firmware recovery via HTTP 103 112 3 Open web page for firmware download gt Start the web browser on your configuration PC gt Inthe address bar of your browser enter the IP address of the gateway http lt IP address gt gt The Firmware Update page opens ree E02 x GE http 10 11 5 24 Pac Gy vs is Backup FW Firmware Upd Firmware Firmware Identification Channel Name Version Date 0 Backup ZW 1 0 1 0 18 4 2017 Firmware Update Choose the new firmware file nxf you want to install Browse Submit your file by clicking on transfer The transfer will take a few seconds WARNING Do not interrupt power or disconnect cable from the system while the transfer is in progress Transfer Cancel Figure 61 Firmware recovery via HTTP as depicted in Internet Explorer A Select firmware file for download gt Click Browse button to open a dialog window for selecting the firmware file you want to download gt Navigate to the directory in which the firmware file is stored select the file then click Open Note The name of the firmware file for the EU5C SWD PROFINET gateway is EO30DOUO nxf Path and name of the selected file are displayed in the field next to the Browse button 5 Download firmware file to gateway gt Cl
43. DT network to the gateway To do so use the SmartWire DT cable SWD4 100LF8 24 and the SWD4 8MF2 relevant blade terminal or prefabricated cables of type SWD4 3 5 10 F8 24 2S Figure 5 Connecting SmartWire DT to gateway Device destruction Switch off the power supply before you are reconnecting slaves in the SmartWire DT system or reconnecting the ribbon cable connection Otherwise the SmartWire DT slaves can be destroyed Detailed instructions on adapting the SmartWire DT external device plug SWD4 8SF2 5 to the 8 pole Smart Wire DT cable are provided in chapter Fitting external device plugs SWD4 8SF2 5 of the manual SmartWire DT The System MNO5006002Z EN previously AWB2723 1617en SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Installing gateway 41 112 7 5 Connecting PROFINET IO gt Connect the RJ45 plug of the PROFINET IO cable to one of the Ethernet connectors on the gateway i 7 N In JANSE _ SZ N x l A Figure 6 Connecting PROFINET IO to Gateway Please observe the following notes on PROFINET IO cabling e Do not use hubs e Use switches only if the switch supports Priority Tagging and LLDP 100 MBit s Full Duplex e Maximum cable length in a segment is 100 meters Please also observe the following note on the cabling of the PROFINET IO Controller
44. Hilscher Ethernet Device Configuration Tool on your configuration PC This tool allows you to check the current IP address of the gateway if the configuration PC and the gateway are connected to the same local Ethernet network An installer for this program can be found on the product DVD in the Software EnDeviceCfg folder the program can also be installed by using the menu of the product DVD 11 3 Step by step instructions 1 Use DHCP server to assign IP address to gateway gt gt gt Disconnect the gateway from the voltage supply Plug a cable connected to the local Ethernet network in which a DHCP server is active into one of the Ethernet RJ45 sockets labeled LAN1 IN or LAN2 OUT on the front side of the gateway Reconnect the gateway to the voltage supply Note gt The L A LINK Activity LEDs of the Ethernet RJ45 sockets remain dark when an Ethernet cable is plugged in while the backup firmware is running even if a successful IP communication with an local Ethernet network has been established gt The backup firmware running in the device now sends a so called DHCPDISCOVER message broadcast into the Ethernet network requesting an IP address from a DHCP server If a DHCP service is available in the network the gateway should be receiving a valid IP address from the server within a few seconds SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 Engli
45. Public Device picture connectors and LEDs 30 112 SWDStatus SmartWire DT Number in configuration Data exchange between gateway and SmartWire DT picture 4 slaves takes place The current actual configuration complies with the gateway target Flashing A necessary SmartWire DT slave is missing or the gateway target configuration does not comply with the actual configuration Nodata exchange between gateway and SmartWire DT slaves Flashing Slave addressing is active after power On or the download of a planned configuration with empty modules Nodata exchange between gateway and SmartWire DT slaves On Short circuit on the 15 V power supply or no SmartWire DT slave is connected Nodata exchange between gateway and SmartWire DT Slaves Moran ge Flashing After having pressed the configuration button The gateway reads the current actual configuration and stores it as target configuration SFPROFINET Duo LED red green System error red On Watchdog timeout channel generic or extended diagnosis present Number in system error picture 5 Flashing DCP signal service is initiated via the bus cyclically at 2 Hz for 3 sec BFPROFINET Duo LED red green Bus error N No configuration or low speed physical link or no physical link Number in picture 6 50 Flashing No data exchange cyclically at 2 Hz LINK RJ45 Ch0 LED gr n amp Chi amp On Gateway has connection to Ethernet l green N
46. S DME PIE ee ee ae eee eee eee ee ee 51 BSNS SD AP ee ee tee 52 Added rolle re ee ee en 53 Added Power Module sense en eeee 54 POL OP een ee 55 Added CPU cerere a E E NS 56 Add PROFINET IO Tee ee TE 57 Add PROFINET IO ya nee 58 Added PROFINET IO network cccccccssccccesceceeeeeeeeeeeeeeeeeeceseuceseneeseeeeseneeeas 58 Added GaC WAV ee ee ane ere ere re 59 Set device name of gateway un nenne 60 Set IP address of CO MCW ee ee ehe 61 Set further gateway parameters 1 ccccccccseccseeceeeseeeseeceseeeeaeeseeeeeeeeseeeesaees 62 Set further gateway parameters 2 ccccceccccscccsececeeeesececeeeeceeeeeeeeceeeseaeessesesaees 62 Set diagnostic address Of Gateway ccccccccscccsscccsseeceeceecesseesseeseeessueesseeesaees 63 Set application parameters Of gateway cccccsecesseeeeeeeeeeeeeeeeeeeeteeetaeeseeeteeees 63 Added SmartWire DT slave arena 65 Configure SmartWire DT slaves 0022200200002n0onnnnnnne nenn ennne nenn nenn nnnnenennennn 66 Set properties of SmartWire DT slave u 2202200s2senseennnennnennnennnnenennnennnennnn 67 Set I O Addresses of SmartWire DT slaves EU5E SWD 2A2A example 67 Set application parameters for SmartWire DT slave EU5E SWD 2A2A CADI ee en ne ae AA eee eee eee ae ee eee 68 Set PG PC Interface Diese nee 70 Set POPC UMS Ace 2 ee see ee een 71 Select Target PLC u02200222002000n0nnnnnonnnnnnnnnnnnnennnn nenne nenn nan
47. S Se a Tee Re 101 11 3 Step by step instructions siiistiniieunnsuscondesaiaisainnssisiseleansiiencle saieaunai enemncuidndenanamadinndaeedaionvwsisahe ii 101 12 TECH al Baar are na ae area ner ER ETEA 105 12 1 Technical data EU5C SWD PROFINET gateway u uuuesssessseensnennnnenennennnenenennenennnn 105 12 2 Technical data PROFINET IO Device Slave u0 2000220020000200nnnn nenne nenne nennen 108 LISt el ai ene ee see an ee herren era Serena een 109 LISTOF 22 9 ae ee ee eee nee 111 CONICS E E ee eee 112 SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 Table of contents 4 112 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Introduction 5 112 1 Introduction 1 1 About this document 1 1 1 Description of the contents This manual describes the Hilscher EU5C SWD PROFINET gateway Here you will find information on how to install configure and operate the gateway This manual is intended for automation technicians and engineers Detailed knowledge of PROFINET IO is presumed In addition readers should also be familiar with the handling of the SmartWire DT system Important gt To avoid personal injuries or damage of electrical devices please read this manual carefully before installing and using the EU5C SWD PROFINET gateway gt Please first read the chapter Safety gt page 16 1 1 2 List of revisions index Date Revisions 2012 06 01 2012 06 2
48. SC SWD PROFINET Gateway is easily commissioned by an automated configuration function On pushing the configuration button on the front of the gateway the gateway scans the current SmartWire DT network configuration the so called actual configuration It then stores the actual configuration as target configuration zero voltage safe in the device thus making the target configuration available for a comparison of actual and targeted SmartWire DT configuration which takes place each time the gateway is being switched on When the gateway is switched on after a target configuration has already been stored the gateway automatically rescans the connected actual configuration and checks it against the target configuration It then gets ready for PROFINET IO and waits for the PROFINET configuration The gateway checks the project configuration which it receives from the PROFINET IO controller against the target configuration Discrepancies between target and actual or between target and project configurations are reported by the gateway via PROFINET Diagnosis The gateway is commissioned in PROFINET by using a PROFINET IO controller engineering tool and a GSDML device description file which is to be imported into engineering tool The GSDML file of the gateway is stored in the EDS EU5C SWD PROFINET Vx x x x directory of the SmartWire DT Gateway Solutions DVD The file contains all configuration data and all possible SmartWire DT slaves as I O module
49. Target Module Target modules Module CPU 315 2 PN DP Select All Cancel Help Figure 34 Select Target PLC gt Inthe Module list select the target module i e the CPU of the PLC then click OK button SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Commissioning gateway 72 112 The Select Node Address dialog box opens Select Node Address Over which station address is the programming device connected to the module CPU 315 2 PN DP Rack Slot 2 Target Station G r Enter connection to target station IP address MAC address Module type Station name Module name P 10 11 12 1 CPU315 SIMATIC3 CPU 315 2 lt MM gt Accessible Nodes Cancel Help Figure 35 Select Node Address 1 gt The CPU of the PLC is not yet displayed in the Accessible Nodes list gt Click View button dv The programming device PC reads the MAC addresses of the connected devices and displays them in the Accessible Nodes list Select Node Address Over which station address is the programming device connected to the module CPU 315 2 PN DP Rack Slot Target Station llocs r Enter connection to target station IP address MAC address Module type Station name Module name P 00 0E 8C CA 9A B2 57 300 lt gt Accessible Nodes 00 0E SC CA SAB2 157 300 Update Cancel Help
50. Yy FE HW Config SIMATIC 300 1 Station Edit Insert PLC View 92 112 Note Usually the GSDML file is delivered together with a bitmap file containing an icon which symbolizes the gateway in the GUI of the programming system This bitmap file must be stored in the same folder as the GSDML file so that it can automatically be installed together with the GSDML file Please note that this bitmap file is not displayed in the Install GSD Files dialog box even if it s actually there Therefore if you are in doubt use the Windows Explorer to check whether the bitmap file is really present in the chosen folder Select the relevant GSDML file then click Install button The GSDML file is installed If an older version of the GSDML file has been installed before this older file is transferred to a backup directory Acknowledge all messages by clicking Yes or OK Click Close button to quit the Install GSD Files dialog box In the Hardware Catalog of the HW Config window the EU5C SWD PROFINET Gateway is displayed under PROFINET IO gt Additional Field Devices gt Gateway Note If the Hardware Catalog is not visible by default you can open it in the menu bar of the HW Config window by choosing View gt Catalog Kak Options Window Help ioe oi SIMATIC 300 1 Configuration SmartWire project SIMATIC 300 1 Slot Designation Press Fi to get Help 8 en dod HO RW py BD xj Fin
51. a chapter are pinpointed particularly and highlighted by a signal word according to the degree of endangerment The kind of danger is specified exactly by the safety message text and optionally by a specific safety sign e The Integrated Safety Messages embedded in operating instructions are highlighted by a signal word according to the degree of endangerment In the safety message the nature of the hazard is indicated Signal words and safety signs in safety messages on personal injury Signal word Meaning SSCS 71NeyN e 4 4 Indicates a direct hazard with high risk which will have as consequence death or grievous bodily harm if it is not avoided Indicates a possible hazard with medium risk which will have as AWARNING consequence death or grievous bodily harm if it is not avoided Indicates a minor hazard with medium risk which could have as consequence personal injury if it is not avoided Table 8 Signal words in safety messages on personal injury Safety sign Sort of warning or principle A Warning of lethal electrical shock gt Principle Disconnect the power plug Table 9 Safety signs in messages on personal injury Signal words and safety signs in safety messages on property damage Signal word Meaning SSCS Tel ale Indicates a property damage message Table 10 Signal words in safety messages on property damage Safety sign Sort of warning or principle E p Warning of property damage by e
52. able Created ccccccecccsccsecsecceeceseceeeceeeceeeeseeteeeseeetseetseeteeetseeseenaes 79 Edit Variable Table ee EEE EEE 80 Montor NPU DIA nee ee er 80 Mod US en ee ee ee nr een 81 Ada Placeholder er oe er ee eee eee ee ae 82 Edit Ethernet Node 1 nennen eher 84 Browse Network ar een ee ee 85 Edit Ethernet Node 2 nee een 86 Acyclic data address MAPPING nee ee een 88 Acyclic data error detection re 89 ITA FC SIS al AAV S zu ste crac sorte xcs ase ees octamer ace oe eeind paste eoerce ota saneabaemoeneintpvpe leitatlaioangenen 92 Firmware update by HTTP as depicted in Internet Explorer 97 Reset by HTTP as depicted in Internet Explorer u0 2002202220022 een 99 Ethernet Device Configuration Tool u0222002000200002nn0nnnn nano nnnn nennen 102 Found gateway in Ethernet Device Configuration TOO u222022200220 nn en 102 Firmware recovery via HTTP as depicted in Internet Explorer 103 Reset after firmware download via HTTP as depicted in Internet Explorer 104 Successful device reset message as depicted in Internet Explorer 104 Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public List of tables Table 1 Table 2 Table 3 Table 4 Table 5 Table 6 Table 7 Table 8 Table 9 Table 10 Table 11 Table 12 Table 13 Table 14 Tabl
53. artWire 5 Ga Input Output modules H Modules for switchgear C Other elements 9 Pilot devices Partner devices 5 0 1 0 H 0 Gateway HMI Comment 2 9 1 0 9 Network Components a SS e Sensors IF SS o OOO an g SIMATIC 300 Jf EU5E 5SwD 2424 256 260 256 259 MM SIMATIC 400 4 EU5E SWD 44x C lt M22 SWD K22LED B lt BE I i M22 SwD K22LED B Hilscher GmbH a Reserved Placeholder for future extensions GSDML V2 2 Hilscher EUISC SWD 201 20404 xml Insertion possible cho 4 Figure 50 Add Placeholder gt The placeholder reserves a SmartWire DT slave address for the SmartWire DT slave which is to be added later gt Save the project transfer it to the PLC Then switch the PLC to RUN mode gt After the PROFINET IO configuration is received from the PLC the SmartWire DT gateway addresses the slaves automatically taking the placeholder into account SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Commissioning gateway 83 112 8 3 6 Acyclical data communication S7 300 PLC SmartWire DT slaves such as the PKE SWD 32 module for the electronic motor protective circuit breaker also supply acyclical data in addition to the cyclical data The function blocks SFB52 RDREC read record and SFB53 WRREC write record are used in STEP 7 for reading and writing acyclical data The
54. ation Table 21 Config LED SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Commissioning gateway 48 112 8 3 Example Using STEP 7 to create a gateway project in PROFINET IO network controlled by S7 300 PLC 8 3 1 Overview The following example shows how to use the STEP 7 programming software to configure and program the EU5C SWD PROFINET Gateway in a PROFINET IO network which is controlled by a S7 300 PLC For this example you need the following hard and software e PROFINET engineering tool Programming device or PC with installed STEP 7 software programming system e GSDML device description file for EU5C SWD PROFINET Gateway e 300 PLC e EU5C SWD PROFINET gateway e PROFINET IO network e SmartWire DT network with slaves To create and implement the gateway project the following steps have to be performed in STEP 7 1 Create new project 2 Import GSDML file 3 Configure PROFINET IO Controller S7 300 PLC 4 Configure PROFINET IO network 5 Configure gateway in PROFINET IO 6 Configure SmartWire DT slaves in PROFINET IO 7 Save and compile configuration 8 Load configuration to S7 300 PLC PROFINET IO Controller 9 Program controller 10 Load controller program to S7 300 PLC PROFINET IO Controller SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06
55. d at FN i Profile Standard v PROFIBUS DP 38 PROFIBUS PA S8 PROFINET I0 Additional Field Devices Gateway 70 EUSC SWD Partner devices H 1 0 Gateway Network Components Sensors Switching devices SIMATIC 300 SIMATIC 400 7 SIMATIC PC Based Control 300 400 SIMATIC PC Station Profinet RT SmartwireDT Gateway GSDML V2 2 Hilscher EU5C SWD Sm 20404 xml Figure 12 Installed GSDML File SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Commissioning gateway 53 112 8 3 2 3 Configure PROFINET IO Controller 1 Add rail carrier rack for IO Controller PLC gt Inthe Hardware Catalog of the HW Config window under SIMATIC 300 gt RACK 300 choose Rail object and drag and drop it into the configuration window GS HW Config SIMATIC 300 1 Seles Station Edit Insert PLC View Options Window Help DESER Be ma MO Bw z i oj x WII SIMATIC 300 1 Configuration SmartWire project a rr ind at ani Profile Standard v H HMI 170 Network Components Sensors Switching devices SIMATIC 300 2 9 C7 CP 300 CPU 300 FM 300 Gateway Ga a IM 300 oO oO a M7 EXTENSION PS 300 Rail 9 SM 300 SIMATIC 400 SIMATIC PC Based Control 300 400 SIMATIC PC Station BES 390 1 7770 0440
56. d Public Commissioning gateway 68 112 Note gt The information as to whether a SmartWire DT slave is available is also reported to the application via the diagnostics function so that you can respond there to the failure of an individual slave Properties EUSE SWD 2A2A R 51 General Addresses Parameters Sy Parameters ey Device parameter amp Presence of device on SWD Device shall be present Replacement by universal module not allowed Type of sensor input 0 voltage 0 104 Type of sensor input 1 voltage 0 104 2 Type of actuator output 0 voltage 0 104 Type of actuator output 1 voltage 0 104 2 Measurement update time 100 ms Averaging On Cancel Help Figure 31 Set application parameters for SmartWire DT slave EU5E SWD 2A2A example gt Inthe Value column click the entry you want to change As soon as you click a value a drop down list opens in which you can select other values Which application parameters can be set here depends on the individual device characteristics of the SmartWire DT slave For information on individual device characteristics please refer to BA the user manual of the corresponding SmartWire DT slave provided by the device s manufacturer SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Commissioning gateway 69 112 For the EU5E SWD
57. dating the firmware of the gateway Power failure during a writing process in the file system can cause severe malfunctioning of the device Important Versions of firmware and device description files functionally belong together This means that after having updated the firmware you may also need to replace the old version of the GSDML file with a new one B Note gt In case of a missing or defective firmware which is indicated by a green POW LED the regular firmware update process described in this chapter is not working In this case proceed as described in chapter REPLACEME SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Updating firmware 96 112 10 2 Prerequisites e The gateway is connected to a power supply e The gateway is connected to an IP network via its Ethernet interface e PC with web browser connected to the IP network e The IP address of the gateway is compatible to the Ethernet subnet of the PC e You know the IP address of the gateway and user name and password needed for accessing the firmware update and reset functions of the web server Default authentication parameters are User Name admin Password admin Note gt The current version of the firmware does not provide options to customize the user authentication of the web server by creating own groups users or passwords IP address of
58. dow Help De SH S SRO elle Ber lt gt DE izl x DB100 SmartWire project SIMATIC 300 1 CPU 315 2 PN DP p e Address Name Type Initial value Comment SWD_OUT BYTE B 16 0 SuD Out END_STRUCT 1 Error 3 Cross references 4 Address info 5 Modify 6 Diagnostics 7 Comparison Press Fi to get Help BE offline Abs lt 5 2 Insert FE de Figure 41 Edit Data Block gt Define Name Type and Initial value of the elements which represent the input and output data gt Inthe menu bar of the editor choose File gt Save then close the editor 3 Edit organization block Note gt You don t need to create a new organization block whereas you had to create a new data block because each project by default already includes an OB1 organization block gt Inthe Blocks node of the project window select the OB1 organization block gt Double click OB1 block or choose Edit gt Open Object in the menu bar gt If you open the OB1 organization block for the first time the Properties sheet of the block opens gt Close the Properties sheet by clicking the OK button SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Commissioning gateway 77 112 gt The organization block is opened in the editor RA AD STL FBD OB1 File Edit Insert PLC Debug Yiew Options Window Help De PHB Bel Cid
59. dware and firmware Important Q Versions of firmware and device description files functionally belong together This means that the firmware version specified here is not compatible with a device description file older than the one specified below and vice versa If your gateway is running with a firmware version older than 1 4 x x it is strongly recommended to update the firmware and to use the version of the device description file specified below Since version 1 4 x x the version of the firmware which has been loaded in the gateway before delivery can be inferred from the device type label attached to the gateway GSDML device description file This manual refers to the following device description file GSDML for EU5C SWD PROFINET gateway GSDML V2 2 Hilscher EU5C SWD XXXXXXXX xml Table 3 Reference to device description file Software tools This manual refers to the following software versions Software Manufacturer Version Ethernet Device Configuration Tool 1 501 STEP 7 Siemens 64 SP5 5 SWD Assit Table 4 Reference to software tools SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Introduction 8 112 Drivers This manual refers to the following driver versions USB Driver for Windows usbser sys Depending on Windows version Table 5 Reference to drivers 1 3 Software package 1 3 1 Overview Hilscher off
60. e 15 Table 16 Table 17 Table 18 Table 19 Table 20 Table 21 Table 22 Table 23 Table 24 Table 25 Table 26 Table 27 Table 28 Table 29 Table 30 SmartWire DT Gateway EU5C SWD PROFINET 111 112 List of tables LIST OF FOV SIONS nen ea ern rennen 5 Reference to hardware and firmware ccccccseccseeccseccseccneceeceeeeceseceueeseeeaneeaeeeeaes 7 Reference to device description file ee ceccsecceeeeeeeeceeececeeeceeeeseeeeeeeeeeaeeeaneeeaes T Reference to software tOOlS ccccecceeeeeeeseeeneeeseeeeeteeteeeceeeeeeseeesaeeeeeeeseeeseeaaees Reference to drivers ee ee ern 8 Directory of the product DVD 2 une 9 Documentation Overview nennen eier een 12 Signal words in safety messages on personal INJULY c cece ceeeeeeeeeeeeeaeeeeeeeeeeees 20 Safety SIGNS IN MESSAGES on personal injury uu22susssseennnenennnnnnnnnnenennnnnnenennnnnn 20 Signal words in safety messages on property damage 22200220022002nn nennen 20 Safety signs in safety messages on property damage cccceeceeseeeeeeeeeteeeeeeees 20 Front view EU5C SWD PROFINET gatewal cccccccccsececeeeceeeeceeeeseeeseeeeseeeeaes 27 LEDs EU5C SWD PROFINET Qatewal cccccecccsecceecceeeceeeeseeeeeceeeeeneeeeeeaneeeaes 28 Descriptions Ordnen ee ann aa ae 29 Description of the LEDs 2 unsere 30 Ethernet interface channel 0 and channel 1 pin assignment RJ45 31
61. e of 0 7 A SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMO7EN Revision 7 English 2015 06 Released Public Installing gateway 39 112 gt Ifnecessary connect the 24 V DC voltage for the contactor coils to the AUX terminals on the front side of the gateway 24V DC OV Figure 4 Gateway power supply Note gt The AUX supply is required if any switching devices are also to be connected for example via the DIL SWD 32 001 002 SmartWire DT slaves The AUX connection provides the supply for activating the contactor coils This supply must be protected by an automatic circuit breaker 3A gG gl or 3 A miniature circuit breaker with a Z characteristic If switching devices with an activation power greater than 3 A are connected an additional feeder module EU5C SWD PF1 or EU5C SWD PF2 must be used Potential conditions between the components The entire SmartWire DT system operates on a common supply voltage Provide a common star point for the earth wiring In this way the various slaves in the SmartWire DT system will not be electrically isolated from one another The PROFINET network and the SmartWire DT system are electrically isolated from one another SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Installing gateway 40 112 7 4 Connecting SmartWire DT gt Connect the SmartWire
62. eeeeesaeessuseseeesegeeseeeeas 38 7 4 Connecting SmartWire DT ou cccccccceccceeeeeeeeceeeseeeeceueeseeeeeaeeseeeesaeesueeseeessgeeseeeseas 40 geo Connecting PROFINET IO res ee eee ee eee ee ee 41 7 6 EMC Conformant Wiring of the Network ccccccccceccceeceseeeeseeeeeeeeeeeeseuseseeeseneeseeeeaes 42 8 Commissioning gateway so a cece eee eee 43 8 1 Configuring SmartWire DT network in gateway cccccecccsecceeeeeeeeeseeeseeeeseeeeseeeseneeaes 43 8 1 1 Reading the SmartWire DT Configuration cccccccecceeeeeeeeeseeeseeeeseeeeaeeeaes 44 8 1 2 Switching on gateway when target configuration is stored 45 8 2 Configuring gateway in PROFINET IO network c cccccecccceeceeeeceeecaeceseeeeseeesaneeaes 46 8 2 1 GSDML device description file cc cecccccceecceeeceeeteeeseeeseeeseeeseeeeeeeseeaseesaes 46 8 2 2 Creating communication with PROFINET IO 0022202220nenennnneneneneneenen 46 8 3 Example Using STEP 7 to create a gateway project in PROFINET IO network controlled 0 ae Garo Pl ae ra ne enge hie 48 8 3 1 VEVO a ee er E 48 8 3 2 Step by step instructions for configuring gateway with STEP 7 49 8 3 3 Step by step instructions for loading PROFINET IO configuration to S7 300 PEO E E S 70 8 3 4 Step by Step Instructions for Programming in STEP 7 Display I O Data 74 8 3 9 Adding SmartWire DT slaves later u002
63. equirements for operation The following prerequisites must be fulfilled to operate the gateway 4 1 Network system e SmartWire DT network with maximum number of up to 99 participants stations slaves and maximum extension of up to 600 meters e PROFINET IO network with PROFINET IO Controller master respectively PLC Maximum cable length for one segment cable between two switches is 100 meters 4 2 Power supply AA WARNING Danger of unsafe operation of the system In safety relevant applications the power supply providing power for the SmartWire DT system must feature a PELV power feed module protective extra low voltage Danger of unsafe operation of the system You must take safety precautions emergency switching off in the external circuitry of the gateway and any power modules type EU5C SWD PF 1 1 or EU5C SWDPF2 1 that are used To do so plan to switch off the power supply to the contactor coils AUX Device destruction Ensure a reliable electrical isolation of the low voltage for the 24 volt supply Only use power supply units complying with IEC 60364 4 41 VDE 0100 Part 410 or HD 384 4 41 S2 Important Please take into consideration the total power consumption of your SmartWire DT network and if necessary plan for an additional feeder module EU5C SWD PF2 You can find information on the power consumption in the operating manuals of the SmartWire DT devices SmartWire DT Gateway EU5C SWD PROFINET
64. ernational copyright law as well as international trade and protection provisions You are not authorized to duplicate these in whole or in part using technical or mechanical methods printing photocopying or other methods to manipulate or transfer using electronic systems without prior written consent You are not permitted to make changes to copyright notices markings trademarks or ownership declarations The included diagrams do not take the patent situation into account The company names and product descriptions included in this document may be trademarks or brands of the respective owners and may be trademarked or patented Any form of further use requires the explicit consent of the respective rights owner 1 5 2 Important notes The user manual accompanying texts and the documentation were created for the use of the products by qualified experts however errors cannot be ruled out For this reason no guarantee can be made and neither juristic responsibility for erroneous information nor any liability can be assumed Descriptions accompanying texts and documentation included in the user manual do not present a guarantee nor any information about proper use as stipulated in the contract or a warranted feature It cannot be ruled out that the user manual the accompanying texts and the documentation do not correspond exactly to the described features standards or other data of the delivered product No warranty or guarantee regarding the
65. ers the optional software package EU5C SWD SW part number 3233 920 for SmartWire DT Gateways The package features the SmartWire DT Gateway Solutions product DVD and a Mini USB cable The SmartWire DT Gateway Solutions product DVD contains the GSDML Device description file necessary for configuring the EU5C SWD PROFINET gateway within the PROFINET network If you do not need the whole package with the USB cable you can download the contents of the product DVD separately and free of charge as ZIP file from our website www hilscher com under Products gt Partner Products gt SmartWire DT gt EU5C SWD PROFINET gt Downloads gt Software 1 3 2 Contents of the product DVD The SmartWire DT Gateway Solutions product DVD contains software for all types of SmartWire DT gateways Depending on the gateway type you are using you will need only certain features of the DVD The product DVD includes e Device description files e Firmware e Eaton SWD Assist software e Wizard for installing the software available on the DVD and for downloading the latest version of the SWD Assist software from the internet e Installation program for USB driver USB driver is needed for connecting the gateway to a PC in order to use the Eaton SWD Assist software e Installation program for the Hilscher Ethernet Device Configuration Tool e Documentation in PDF format e Installation program for Adobe Reader SmartWire DT Gateway EU5C SWD PROFINET Hilsc
66. eway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public List of figures Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 Figure 9 Figure 10 Figure 11 Figure 12 Figure 13 Figure 14 Figure 15 Figure 16 Figure 17 Figure 18 Figure 19 Figure 20 Figure 21 Figure 22 Figure 23 Figure 24 Figure 25 Figure 26 Figure 27 Figure 28 Figure 29 Figure 30 Figure 31 Figure 32 Figure 33 Figure 34 Figure 35 Figure 36 Figure 37 Figure 38 Figure 39 SmartWire DT Gateway EU5C SWD PROFINET 109 112 List of figures Data flow EU5C SWD PROFINET Qateway ccccccccceecececeeeneeeceeeesseeesseeeeaees 21 Pinning of the Ethernet interface RJ45 u022202220020n00nnno nenn nenn nano nnnnn nenn 31 Mounting principle of the gateway uusssuenssensnnennnnnnnnenenennnnennnnnnnnenenen nenne nennen 35 Gateway power Supply cuisine nina nen een een 39 Connecting SmartWire DT to gateway cccccccccsececeeeceeeeseeeeeeeeseueeseeeseneesaees 40 Connecting PROFINET I to Gateway ne 41 Create new project in SIMATIC Manager 22200220022000200 nenne nenn nenne nennen 49 PLC added to the DFOJERL esta naar 50 Hardware Configuration WiIndOw cccccscccssccceseeeneeeeneeceeeseseseeeesaeeseueesaeeseas 50 Install GSD Files dialog DOK an an enien 51 Select O
67. gateway On shipment the default IP address of the gateway is 0 0 0 0 In principle the gateway receives its IP address temporarily from the PROFINET IO controller via DCP protocol and on each restart anew A statically stored IP address can also be assigned to the gateway by the DCP protocol The DCP protocol is standardized and usually supported by PROFINET IO engineering tools Apart from address assignment by the PROFINET IO controller you can assign the IP address of the gateway via DCP by using one of the following tools e Hilscher Ethernet Device Configuration Tool An installer for this program is stored on the product DVD in the directory Software EnDeviceCfg It can also be installed by using the menu of the Product DVD For information about how to use this tool please refer to the operating instruction manual Ethernet Device Configuration which is stored on the product DVD in the Documentation english 1 Software Ethernet Device Setup Utility directory gt Note gt The IP address assigned by the Ethernet Device Configuration Tool is stored volatile in the gateway and is thus lost after power off at the device Note also that in case of a missing or defective firmware which is indicated by agreen POW LED the tool will still be able to locate the gateway via netIDENT protocol but it will not be able to assign an IP address to the gateway then not even a temporary IP address In this case you have to use a DHCP ser
68. h 2015 06 Released Public Commissioning gateway 51 112 8 3 2 2 Import GSDML device description file gt Inthe menu bar of the HW Configwindow choose Options gt Install GSD File gt Thelnstall GSD Filesdialog box opens Install GSD Files Install GSD Files from the directory C PROGRAMME SIEMENS STEP7 S7TMP Browse nst Show Log elect All Figure 10 Install GSD Files dialog box Choose the directory where the GSDML file you want to install is stored In the drop down list located next to the Install GSD Filesentry select from the directory entry then click Browse button gt The Windows Search Folder dialog opens gt Navigate to the relevant directory select relevant folder and click OK button The Search Folder dialog closes and in the Install GSD Files dialog box all GSD and GSDML files stored in that folder are displayed Install GSD Files Install GSD Files from the directory D 1EDS Browse Fie Reese Version Languages GSDML VO 1 Hilscher xy2 20120101 xml 01 01 2012 12 00 00AM V0 1 English German GSDMLV2 2 HilscherEU5C SwD 20120227 xml 02 27 2012 12 00 00AM _V2 2 English German HIL_0B44 GSD Default Install Show Log Select All Deselect All Figure 11 Select GSDML File SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Commissioning gateway
69. her 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Introduction 9 112 The product DVD has the following directories PDF manuals in German and English and installation program for Adobe Reader EDS GSDML device description files and bitmaps to be imported directly into the PROFINET IO engineering tool Firmware Loadable gateway firmware scommand Files for start screen of product DVD Setups amp Drivers SWD Assist software Folder SWD Assist Wizard for installing the software available on the DVD and for downloading the latest version of the SWD Assist software from the internet Folder Setup Installation program for Ethernet Device Configuration Tool Folder EnDeviceCfg Installation program setup exe and INF and CAT files for Windows USB driver Folder USB Driver Table 6 Directory of the product DVD Note gt You can use the wizard on the product DVD to download updates of the Eaton SWD Assist software or you can download SWD Assist directly from the www moeller net website under Support gt Download Center Direct link http downloadcenter moeller net en software a487d8b7 da91 486f b3ba a7ca2035db99 SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Introduction 10 112 1 3 3 How to use the product DVD Insert the SmartWire DT Gateway Solutions product DVD into the DVD dr
70. hina Hilscher Systemautomation Shanghai Co Ltd 200010 Shanghai Phone 86 0 21 6355 5161 E Mail info hilscher cn Support Phone 86 0 21 6355 5161 E Mail cn support hilscher com France Hilscher France S a r l 69500 Bron Phone 33 0 4 72 37 98 40 E Mail info hilscher fr Support Phone 33 0 4 72 37 98 40 E Mail fr support hilscher com India Hilscher India Pvt Ltd Pune Delhi Mumbai Phone 91 8888 750 777 E Mail info hilscher in Italy Hilscher Italia S r l 20090 Vimodrone Ml Phone 39 02 25007068 E Mail info hilscher it Support Phone 39 02 25007068 E Mail it support hilscher com SmartWire DT Gateway EU5C SWD PROFINET DOC120304UMOTEN Revision 7 English 2015 06 Released Public 112 112 Japan Hilscher Japan KK Tokyo 160 0022 Phone 81 0 3 5362 0521 E Mail info hilscher jp Support Phone 81 0 3 5362 0521 E Mail jp support hilscher com Korea Hilscher Korea Inc Seongnam Gyeonggi 463 400 Phone 82 0 31 789 3715 E Mail info hilscher kr Switzerland Hilscher Swiss GmbH 4500 Solothurn Phone 41 0 32 623 6633 E Mail info hilscher ch Support Phone 49 0 6190 9907 99 E Mail ch support hilscher com USA Hilscher North America Inc Lisle IL 60532 Phone 1 630 505 5301 E Mail info hilscher us Support Phone 1 630 505 5301 E Mail us support hilscher com Hilscher 2012 2015
71. ick Transfer button to download the new firmware file to the gateway SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Firmware recovery via HTTP 104 112 After you have started the download by clicking the Transfer button the validity of the firmware file is being checked by the system If the file fails the validity check an error message will be displayed If the file passes the gateway requests you to perform a reset in order to start the new firmware Oo http 10 11 5 24 P BC ty us 93 Backup FW Firmware Upd Firmware Transfer succeeded You should reset the device to apply the changes Firmware is being restarted and connections may be interrupted or time out Ethernet connection may be lost if IP parameters are not stored permanently Please confirm you want to reset the device submit cancel Figure 62 Reset after firmware download via HTTP as depicted in Internet Explorer 6 Perform reset gt Activate the checkbox in front of Please confirm to acknowledge that you want to reset the gateway Note gt You can use the Cancel button to uncheck the checkbox in front of Please confirm gt Click Submit button to start the reset After successful reset the following message is displayed i Oo http 10 11 5 24 reset Pr Bo ty ue 93
72. interchange is possible between the SmartWire DT slaves and the gateway in principle also communication between the gateway and the controller can be established via PROFINET IO gt Connect the gateway to the PROFINET IO bus gt Load the PROFINET IO configuration and possibly a controller program to the PLC On uploading the PROFINET IO configuration program from the engineering tool to the PLC the configuration of the entire PROFINET IO network is transferred to the PROFINET IO Controller master The PROFINET IO Controller then transfers the planned SmartWire DT configuration which is included in the PROFINET IO configuration to the gateway where it is being tested If the planned configuration complies with the stored gateway configuration all status LEDs indicate a green continuous light Any errors that occur are indicated via the Application status LED and the Config status LED SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Commissioning gateway 47 112 LED eoor Ste meaning SSCS APLApplication Duo LED red green status Green On The communication on PROFINET and SmartWire DT is in cyclic data Number in exchange and the gateway function is executed picture 2 Migreen Flashing 2 s Gateway is initialized but the communication on PROFINET is not in off 0 5 s on cyclic data exchange gt 09 Flashing 2 s Gateway is initiali
73. ir respective legal owners SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMO7EN Revision 7 English 2015 06 Released Public Safety 16 112 2 safety 2 1 General note The user manual all accompanying texts and the documentation are written for the use of the products by educated personnel When using the products all safety instructions property damage messages and all valid legal regulations have to be observed Technical knowledge is presumed The user has to assure that all legal regulations are obeyed 2 2 Intended use The purpose of the EU5C SWD PROFINET gateway described in this user manual is to create a connection between SmartWire DT slaves and an overriding PROFINET IO controller master device 2 3 Personnel qualification The gateway must be installed configured and removed by qualified personnel only Job specific technical skills for people professionally working with electricity must be present concerning the following issues e Safety and health at work e Mounting and connecting of electrical equipment e Measurement and analysis of electrical functions and systems e Evaluation of the safety of electrical systems and equipment e Installing and configuring IT systems 2 4 References safety S1 ANSI Z535 6 2006 American National Standard for Product Safety Information in Product Manuals Instructions and Other Collateral Materials S2 IEC 60950 1 Information technol
74. ive of your configuration PC If the auto start function of your DVD drive is enabled the start screen of the DVD automatically opens You can also start the DVD by double clicking the SmartWire exe file in the root directory of the DVD In the menu of the start screen of the DVD click Install Planning and Configuration Tools to open a wizard for installing the software programs stored on the DVD The wizard also helps you to download the latest version of the Eaton planning software SWD Assist from the internet It automatically checks for already installed software components which e g might have been installed for an earlier project and lists the missing components accordingly The following options might be offered e USB Driver installs USB driver for Windows on your PC e Download Center SWD Assist manual update connects your browser to a web page where you can download the latest version of the SWD Assist software e SWD Planning Software SWD Assist Vx xx installs the SWD Assist software version provided on the DVD e Ethernet Device Scanner Configuration Tool installs the Hilscher Ethernet Device Configuration Tool e GSDML EDS ESI files HTML page opens a web page containing links to the device description files In the main menu of the start screen of the DVD you can furthermore open a web page which provides an overview of all available documents menu Documentation You can also directly open the folder con
75. lectrostatic discharge Table 11 Safety signs in safety messages on property damage SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMO7EN Revision 7 English 2015 06 Released Public Description of the EU5C SWD PROFINET gateway 21 112 3 Description of the EU5C SWD PROFINET gateway 3 1 Function The EU5C SWD PROFINET Gateway integrates a SmartWire DT network into a PROFINET network The Gateway creates a data connection between the participants the slaves of the subordinate SmartWire DT network and the controller the master or PLC of the superordinate PROFINET IO network The gateway acts as master in the SmartWire DT network and as modular IO Device slave in the PROFINET network It thereby presents each connected SmartWire DT participant as individual module to the PROFINET IO Controller The cyclic process data is exchanged transparently between both networks 1000 Bytes of process input output data can in sum be exchanged with up to 99 SmartWire DT participants slaves PROFINET IO Controller Master PROFINET IO interface Slave EU5C SWD PROFINET Gateway Slave 1 Slave 2 a 5 SmartWire Interface eee 99 Figure 1 Data flow EU5C SWD PROFINET gateway SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Description of the EU5C SWD PROFINET gateway 22 112 3 2 Configuration The EU
76. memory 0 1 ms 1000 instructions PROFINET connection 57 Communication loadable FBs FCs m PRRERRRREEE Gateway Do not use router IP address Subnet mask FE 255 255 0 ef Use router Address Subnet not networked o Insertion possible Figure 15 Add CPU gt Inthe Parameters tab of the Properties Ethernet Interface sheet enter IP address and Subnet mask or accept the preset default values You can also set the IP address later during the next step when you add a PROFINET IO network to the project Note Consult you network administrator about IP addresses if you intend to use your company s Ethernet network gt Click OK button to close the Properties Ethernet Interface sheet SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Commissioning gateway 56 112 After the Properties Ethernet Interface sheet is closed the added CPU with its interfaces is displayed in the rail in the configuration window GA HW Config SIMATIC 300 1 3 5 Station Edit Insert PLC View Options Window Help Dee h 6 ae mae MO Bw A SIMATIC 300 1 Configuration SmartWire project fol msi 1 Configuration proj Find lt r F 7 4 PS 307 104 Profile Standard o 9 CPU 312C CPU 313 CPU 313C CPU 313C 2 DP CPU 31
77. n Flashing Slave addressing is active after power On or the download of a planned configuration with empty modules Nodata exchange slaves W Flashing After having pressed the configuration button The gateway reads the S Orange current actual configuration and stores it as target configuration Table 19 SWD LED SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMO7EN Revision 7 English 2015 06 Released Public Commissioning gateway 46 112 8 2 Configuring gateway in PROFINET IO network 8 2 1 GSDML device description file In the PROFINET engineering tool of the PLC programming system the EU5C SWD PROFINET Gateway is integrated as PROFINET IO Device i e aS Slave device For this a device description file GSDML file containing a standardized description of the gateway is necessary You will find the GSDML file on the product DVD in the EDS EU5C SWD PROFINET Vx x x x directory You can also download the latest version of a GSDML file from our website www hilscher com under Products gt Partner Products gt SmartWire DT gt EU5C SWD PROFINET gt Downloads Copy the relevant GSDML files together with the relevant bitmap files to the relevant directory of your PROFINET engineering tool or use the import function of the tool For further information on this please refer to the documentation of your engineering tool 8 2 2 Creating communication with PROFINET IO If a data
78. n older version of the GSDML file to be used to configure the gateway Older versions of GSDML files are moved to a backup directory when new GSDML files are being imported to STEP 7 see section REPLACEME gt page 51 3 Define IP address for gateway in PROFINET IO gt Inthe upper part of the configuration window right click the gateway symbol then choose Edit PROFINET IO System IP address from the context menu gt The Edit IP Addresses dialog box opens E Edit IP Addresses PROFINET IO System PROFINET I0 System PROFINET 0 System 100 PROFINET IO Controller Smartwire project SIMATIC 300 1 PN I0 Line Device Name IP Address 1 eusc swd profinet 192 168 0 2 Permissible IP addresses of IO devices 192 168 0 2 192 168 0 254 Cancel Help Figure 22 Set IP address of gateway gt Accept the IP address determined by the PROFINET IO controller or click the IP Address field and enter a new address gt Click OK button to close Edit IP Addresses dialog box SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Commissioning gateway 62 112 4 Set further parameters of gateway gt Inthe upper part of the configuration window select the gateway symbol position 1 then double click the gateway entry on Slot 0 position 2 in the lower part of the configuration window fi HW Config SIMATIC 300 1 SEE Station
79. nd device description file eee eeceeece eee eeeeeeeeeseteeeeeeeteeesseeeeeeees 23 4 Requirements for operation cccsccceeceeeceeecceeecneeeeeeeneceneceneseaeeeeeeneeeneseneeeneeenesenesenesoneaens 25 Asl NOIWOK SV SUS 10 ee ee een een 25 4 2 POWER SUPD ee ee er een no ee 25 4 2 1 POW power COMME EN Oasen dene ren 26 4 2 2 AUX DOWER COMME CO ee eek 26 5 Device picture connectors and LEDS 220220002002000n0nn0nannnnunnnnnnun ann nnnn nun nun anna nun 27 SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UM07EN Revision 7 English 2015 06 Released Public Table of contents 3 112 5 1 Device DIENTE nee enge EEE 27 5 2 Positions and meaning of the LEDS eu nenne 28 5 2 1 POSILIONSSOL NE LEG sier nE ee 28 22 DESEIBHONS OL Ne LEDS en a nie cutee a NATA 29 5 3 Pinning of the Real Time Ethernet interface u02220022000200000n0 nenne nenn anne anne nnnenn 31 5 4 Device type JADE eee ee een eee een 32 o GENO STArleG eee ee ee ee een ee 33 7 HS GING Gate Wa a Ener EEE En 34 1 Safety MESSAGE een eia een Ea nee een ee aR Er 34 7 2 Mounting Gate Wy ee ee ae ee ee 35 1 2 1 Mounting gateway onto top Nat ralll cccccccceeceeceeceeeseesaeeseeceeesseeseeesaes 35 7 2 2 Removing gateway from top Nat rail cccccccceccceeccceeeeeeeeseeeeaeeeseeeeseeeseeeeaes 37 7 3 Connecting gateway to power SUDDPIY ccccccccceececeeeceeeeeeeeeee
80. nenennnnne nenn 13 1 5 3 EXEIUE ION OT liability ee eisen 14 1 5 4 UV AT ANNE ee ee ee ee ee ne ee eure 14 1 5 5 EXPO FEC UN ANON ea E AE E A EAE 15 1 5 6 Registered trademarks cccccccscceececeecceeceecaeecaeeseeecaeecseesaeeceeesaeeceeecueeaaes 15 P E o E A N A EAE EEA E E A N E AE E E AE rs 16 ZN CONE OG ee a E N E A A 16 22 Miene dU een een er een ee 16 23 Personnel qualification ee nee ee 16 2 4 References safety u ee een 16 2 5 Safety instructions to avoid personal injury u 2220022002220nenennnnennnennnne nenn nnnnennnnennnenn 17 2 5 1 El cirical SHOCK Nazal O sssini aa A EO RRN 17 2 5 2 Danger of unintended starting up of machines 2 20222002200 seen nenn 17 2 6 Safety instructions to avoid property damage cccceecceseeseeeeeeceeeeeeeeeeeteeeteeetseeeeeeees 18 2 6 1 General safety instructions concerning supply Voltage ccceeceeeeeeeeeeees 18 2 6 2 Device destruction by exceeding allowed supply voltage ccccceeeeeeeees 18 2 6 3 Electrostatic SENSITIVE COVICE cccceccecceecceeeseeceeceeeceeceeeceeceeceeseeesseseeseeeeaes 19 27 Labeling of safety messages nu ea ee eier 20 3 Description of the EU5C SWD PROFINET gateway uu 222020000000n0n0nnnnun nun nnnn nun nun une 21 IL FCO n Ea ee E E 21 32 8911 810 2110 a nenne EE ESEE 22 33 MANO GCS EA EEA EA AANA ESA 23 MAINO SS ee nee 23 3 5 Updating firmware a
81. ng installation 3 SmartWire DT SmartWire DT and programming of the Units individual SmartWire DT MNO5006001Z_EN pdf slaves SmartWire DT Information on function MNO5006002Z EN Documentation english The System installation 3 SmartWire DT SmartWire DT commissioning and The System diagnostics of the MNO05006002Z_EN pdf SmartWire DT system Ethernet Device Operating Instruction Hilscher DOCO504020I05EN Documentation english Configuration Manual of Hilscher 1 Software Ethernet Device Setup Ethernet Device Utility Configuration Tool Ethernet Device Configuration Ol xx EN pdf PROFINET Information on PROFIBUS Order No 8 072 Documentation english Installation PROFINET cabling Nutzer idantineation 5 Installation Instructions Guideline for organisation TC2 08 0002 PROFINET Guideline Assembly 8 Cabling and e V 072 V10 Jan09 pdf Assembly SWD Assist Online help for SWD Eaton Included in SWD Assist software Online help Assist planning software Table 7 Documentation overview SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Introduction 13 112 1 5 Legal notes 1 5 1 Copyright Hilscher 2012 2015 Hilscher Gesellschaft f r Systemautomation mbH All rights reserved The images photographs and texts in the accompanying material user manual accompanying texts documentation etc are protected by German and int
82. ns are limited to damages that are foreseeable and typical for this type of contract It is strictly prohibited to use the software in the following areas e for military purposes or in weapon systems e for the design construction maintenance or operation of nuclear facilities e in air traffic control systems air traffic or air traffic communication systems e in life support systems e in systems in which failures in the software could lead to personal injury or injuries leading to death We inform you that the software was not developed for use in dangerous environments requiring fail proof control mechanisms Use of the software in such an environment occurs at your own risk No liability is assumed for damages or losses due to unauthorized use 1 5 4 Warranty Although the hardware and software was developed with utmost care and tested intensively Hilscher Gesellschaft fur Systemautomation mbH does not guarantee its suitability for any purpose not confirmed in writing It cannot be guaranteed that the hardware and software will meet your requirements that the use of the software operates without interruption and that the software is free of errors No guarantee is made regarding infringements violations of patents rights of ownership or the freedom from interference by third parties No additional guarantees or assurances are made regarding marketability freedom of defect of title integration or usability for certain purpo
83. nthe project tree select Blocks node SmartWire project C Programme Siemens Step s proj SmartWir Smartwire project System data iG 061 DB100 SIMATIC 300 1 CPU 315 2 PN DP E7 57 Programl1 Sources a Blocks Figure 43 Select Blocks Node in SIMATIC Manager gt Inthe menu bar of the SIMATIC Manager choose PLC gt Download gt The code blocks are loaded to the PLC 5 Create variable table gt Inthe project tree select the CPU SmartWire project C Programme Siemens Step s proj SmartWir lE Smartwire project z 5 Program 1 SIMATIC 300 1 p EEE sq 57 Program 1 Figure 44 Selected CPU in Project Tree gt Inthe menu bar of the SIMATIC Manager choose Insert gt S7 Block gt Variable Table SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Commissioning gateway 79 112 dv The Properties sheet of the variable table opens Properties Variable Table General Part 1 General Part 2 Attributes Name VATT Symbolic Name Symbol Comment Project path St locati of ze a C Programme Siemens Step s proj Smartwir Code Interface Date created 04 23 2012 12 41 08 PM Last modified 04 23 2012 12 41 08 PM 04 23 2012 12 41 08 PM Comment Cancel Help Figure 45 Create Variable Table gt Inthe Symbolic Name field of the General Part 1 tab en
84. o namen name nenne nennen 71 Select Node Address 1 Ve ee ea ee tee 72 Select Node Address 2 2220222002220020000nnno nenn nnnne nenn nenne nenn nenn nnnnennnenenne nennen 72 Select Node Address 3 02220222002200020000nnno nenn nnnnennnn nenne nenn nnnnnnnnn name nenne nennen 73 Project Window in SIMATIC Manager 2220022200240020000nnno nenn anne anne nnnnn nenn 74 Create Data Block 22002220020200nnnennnnnnnennnnennnnnnnnonnnnnnnne nenne nenn anne nnnn namen ennenen 75 Hilscher 2012 2015 DOC120304UM07EN Revision 7 English 2015 06 Released Public List of figures Figure 40 Figure 41 Figure 42 Figure 43 Figure 44 Figure 45 Figure 46 Figure 47 Figure 48 Figure 49 Figure 50 Figure 51 Figure 52 Figure 53 Figure 54 Figure 55 Figure 56 Figure 5 7 Figure 58 Figure 59 Figure 60 Figure 61 Figure 62 Figure 63 SmartWire DT Gateway EU5C SWD PROFINET 110 112 Data Block Created Ee et ee ae ee eee en ee eee ees 75 Edit Dala BLOCK een ent nn a en ee eo ne EEE 76 Edit Organization BIOCK nen een are 77 Select Blocks Node in SIMATIC Manage cccccsccceececeeeeeseeseneeseeesseeeeaues 78 Selected CPU in Project Tree ccccscccseccceecececesaeeceseeccsnecseescesesaeeseseesaseenees 78 Create Variable Tape aieecceteitse carts oid minum usionienneneste rien ond ouietoutosbovineedseviianiesetanuidevireonte 79 Variable T
85. o the project 2 Configure SmartWire DT slaves gt Inthe upper part of the configuration window select the gateway symbol position 1 then double click the slave entry e g EU5E SWD 2A2A on Slot 1 position 2 in the lower part of the configuration window fi HW Config SIMATIC 300 1 Station Edit Insert PLC Yiew Options Window Help DESER 6 Be dod MO Bw fil SIMATIC 300 1 Configuration SmartWire project Ji PS 307 104 m E CPU 315 2 PN DP w PROFIBUIS PA i a 382 PROFINET 10 g awo 10 E Additional Field Devices ld Por 7 e 3 Gateway a EUSC SWD B EUSC SWD PROFINET J Eaton a Input Output modules 4 EUSE SWD 2424 EUBE SWD 44 EUSE SWD 4D2R EUSE SWD 4D4D EUSE SWD 4DX EUSE SWD 4PT EUSE SWD 8DX EU5E SWD x8D Comment ae Modules for switchgear S Other elements E Pilot devices artner devices SmartWire Al EZA a fg euseswoaa 2 en ee IF Euse swo aax A POP HE Hg M22 5WD K22LED8 270260 BEE SESS EEE EES eee Press Fi to get Help Figure 28 Configure SmartWire DT slaves gt The Properties sheet opens In the General tab you can accept or change the preset name of the SmartWire DT slave SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Commissioning gateway 67 112 Properties EUSE SWD 2A2A R S1 General Addresses Parameters Short descri
86. ogy equipment Safety Part 1 General requirements IEC 60950 1 2005 modified German Edition EN 60950 1 2006 S3 EN 61340 5 1 and EN 61340 5 2 as well as IEC 61340 5 1 and IEC 61340 5 2 SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Safety 17 112 2 0 Safety instructions to avoid personal injury To ensure your own personal safety and to avoid personal injury you must read understand and follow the following safety instructions in this manual and all warning messages before you install and operate the gateway 2 5 1 Electrical shock hazard Take care of the following safety measures before installing or uninstalling the gateway e First disconnect the power plug of the device e Make sure that the device is disconnected from the power supply e Cover or enclose neighboring units that are live Devices that are designed for mounting in housings or control cabinets must only be operated and controlled after they have been installed with the housing closed Desktop or portable units must only be operated and controlled in enclosed housings 29 2 Danger of unintended starting up of machines e Install automation devices and related operating elements in a way that they are well protected against unintentional operation e Emergency stop devices complying with IEC EN 60204 1 must be effective in all operating modes of the automation device
87. onditions Electromagnetic compatibility EMC Electrostatic discharge Air discharge Level 3 8 kV IEC EN 61131 2 2008 Contact discharge Level 2 4 kV Electromagnetic fields 80 1000 MHz 10 V m IEC EN 61131 2 2008 1 4 2 GHz 3 V m 2 2 7 GHz 1 V m Radio interference suppression EN 55011 Class A SmartWire DT Burst Supply cables 2 kV IEC EN 61131 2 2008 Level 3 PROFINET bus cable 1 kV SmartWire DT cables 1 kV Surge Supply cables 0 5 kV IEC EN 61131 2 2008 Level 1 PROFINET bus cable 1 kV Radiated RFI 0 15 80 MHz 10 V 80 AM 1 KHz IEC EN 61131 2 2008 Level 3 SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Technical data 106 112 Category Parameter Supply voltage Uny Value Rated operational voltage 24V DC 15 20 lt 5 Yes 3A Note If contactors with a total power consumption gt 3 A are connected a power feeder module EU5C SWD PF 1 2 has to be used No external fuse FAZ Z3 Typ 1W Input voltage residual ripple Protection against polarity reversal max current Short circuit strength Heat dissipation Z Potential isolation Rated operating voltage of 24 V DC Typical U ux 0 2 V slaves Supply voltage 24 V DC 15 20 lt 5 Yes Supply voltage Upow Input voltage residual ripple Protection against polarit
88. onse to a read request followed by ErrorDecode 80 PNIORW user error A description of ErrorCode1 which conveys the actual message is provided in the following table ErrorCode2 is not defined aare pe p o read request OxDEBOBO Bso JAcoessinvalldinien oxDEs0oB6 ee Aaccessdenea oxDEs0B9 eo facoessinvaiatype OxDEBOBDx Bo Access user specifico Table 24 Acyclic data error codes for read requests SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMO7EN Revision 7 English 2015 06 Released Public PROFINET IO data communication 91 112 Error codes for write requests All error messages supported by the gateway concerning read requests start with ErrorCode DF ODWriteRes negative response to a write request followed by ErrorDecode 80 PNIORW user error A description of ErrorCode1 which conveys the actual message is provided in the following table ErrorCode2 is not defined Error message for write ErrorCode1 request osoo feo Access invalid indes oxDF80B6xx ee Access invalid range of a parameterwalue osoa feo fAaccess bap OxDF80BDxx feo Access user speciet Table 25 Acyclic data error codes for write requests SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMO7EN Revision 7 English 2015 06 Released Public PROFINET IO data communication 92 112 9 2 Alarms and diagnosis controlled by the gateway
89. orType value carries the Vendor ID of the reporting SmartWire DT slave with the formula VendorID 1 the second byte transparently carries the unaltered SWD diagnosis code VendorlD 1 ChannelErrorType OXXXYY Sa SWD Diagnosis code Example 1 Eaton has the Vendor ID 01 If an Eaton SWD device reports diagnosis code 0x19 this will thus be conveyed as ChannelErrorType 0x0219 Example 1 Phoenix has the Vendor ID 02 If a Phoenix SWD device reports diagnosis code 0x21 this will thus be conveyed as ChannelErrorType 0x0321 For the meaning of the specific diagnosis codes please consult the BA user manual of the corresponding SmartWire DT slave provided by the device s manufacturer SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Updating firmware 95 112 10 Updating firmware 10 1 Overview The EU5C SWD PROFINET Gateway is shipped with its most recent firmware already loaded Since version 1 4 x x the version of the loaded firmware is stated on the device type label The integrated web server of the gateway provides a function to update the firmware of the gateway by HTTP via its Ethernet interface All you need is a PC with an ordinary web browser connected to the gateway via the Ethernet network Hazard of device damage by disruption of voltage supply during firmware update Do not interrupt the voltage supply while up
90. ose PLC gt Ethernet gt Edit Ethernet Node A blank Edit Ethernet Node dialog box opens Edit Ethernet Node Ethernet node Nodes accessible online MAC address Browse Set IP configuration Use IP parameters Gateway IP address le Do not use router Subnet mask C Use router C Obtain IP address from a DHCP server Identified by Client Il Client ID Assign device name Device name Reset to factory settings Close Figure 51 Edit Ethernet Node 1 gt Below Nodes accessible online click Browse button SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Commissioning gateway 85 112 gt The Browse Network dialog box opens After a short while all found nodes are displayed Browse Network 2 Nodes Start rel IP address MAC address Name 00 02 42 24 D6 E1 EUSC SWD eudc swd 03 10 11 12 1 00 0E SC C4 94 62 57 300 v Fast search Flash MAC address 100 02 42 24 D8 E1 Cancel Help Figure 52 Browse Network gt Select the entry for the gateway then click OK button gt Note gt You can make the SF LED of the gateway flash by clicking the Flash button in this dialog box This may help you to physically identify the gateway in a complex installation Click Stop Flash button to switch off the LED Sma
91. over from the imported GSDML file The PROFINET IO controller the PLC uses this name to address the gateway in the network gt Keep the preset name if you intend to use only one EU5SC SWD PROFINET Gateway in your PROFINET network If you intend to use more than one gateway you must define a unique new name for each additional gateway In that case you can keep the preset name for your first gateway but have to enter a new Device name in the corresponding Properties sheets of the other gateways Important Please note that you need to define these new names not only within the STEP 7 configuration but that you also need to transfer the new names onto the additional gateways and save them there in order to overwrite the preset standard name stored in each gateway Otherwise the additional gateways will not respond when contacted by the PROFINET IO controller For information on how to change the device name on a gateway see section REPLACEME gt page 83 gt Click OK button to close the Properties sheet SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Commissioning gateway 61 112 Note gt If you have installed more than one version of aGSDML device description file in the course of time you can use the Change Release Number button in the General tab of the Properties sheet to open a dialog box in which you can choose a
92. ox in front of Please confirm SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Firmware recovery via HTTP 100 112 11 Firmware recovery via HTTP 11 1 Overview If the POW system status LED of the gateway shows steady green light the regular firmware of the gateway is defective or missing for the position of the POW LED see section Positions of the LEDs gt page 28 In this case only the so called backup firmware is running and the device is not able to perform its normal gateway functions This state can be resolved by downloading a fresh i e uncorrupted firmware file into the gateway via HTTP protocol The backup firmware which is part of the boot strap loader running in the gateway carries a web server functionality for downloading a firmware file comfortably via its Ethernet interface For this you just have to connect the gateway via its Ethernet interface to an active DHCP server and a configuration PC The purpose of the DHCP server is to assign an IP address to the gateway This assigned IP address can then be used by the configuration PC to connect to the download function of the backup firmware running in the gateway in order to download the new firmware file via ordinary web browser If you do not know the exact IP address assigned to the gateway by the DHCP server you can use the Hilscher Ethernet Device Config
93. ption EUSE SWD 2424 2 analogue inputs and 2 analogue outputs EUSE S WD 2424 Comment Cancel Help Figure 29 Set properties of SmartWire DT slave gt Click Name field and enter a new name if necessary In the Addresses tab you can accept or change the addresses which are reserved within the controller for the input and output data of the SmartWire DT slave Properties EUSE SWD 2A2A R S1 General Addresses Parameters Inputs Start EEE Process image End 260 Outputs Start 256 Process image End 259 Cancel Help Figure 30 Set I O Addresses of SmartWire DT slaves EU5E SWD 2A2A example gt Note gt On adding a SmartWire DT slave the addresses are assigned automatically by the system The preset address value ensures that the start address is within the process image of the inputs and outputs gt Click the Start field and enter a new start address if necessary In the Parameters tab you can set the application parameters of the SmartWire device in regard to its function as slave in the SmartWire DT network For example you can parameterize the transient behavior for each SmartWire DT slave This defines how the gateway is to respond if a SmartWire DT slave is not present The standard setting is that all SmartWire DT slaves have to be available SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UM07EN Revision 7 English 2015 06 Release
94. re circuit breakers or fuses Miniature circuit breaker 24 V DC for AUX e Cable protection in accordance with DIN VDE 0641 Part 11 IEC EN 60898 Miniature circuit breaker 24 V DC rated operational current 3 A trip type Z or Fuse 3A utilization class gL gG e Cable protection for cable AWG 24 in accordance with UL 508 und CSA 22 2 No 14 Miniature circuit breaker 24 V DC rated operational current 2 A Tripping characteristics Z or Fuse 2A SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Device picture connectors and LEDs 27 112 5 Device picture connectors and LEDs 5 1 Device picture 1 2 3 4 nis 9 6 7 8 24 V power supply POW PROFINET IO interface RJ45 LEDs communication status PROFINET IO Mini USB interface Configuration button LEDs Gateway 24 V power supply AUX SmartWire DT connection plug 8 pole Table 12 Front view EU5C SWD PROFINET gateway SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Device picture connectors and LEDs 28 112 5 2 Positions and meaning of the LEDs 5 2 1 Positions of the LEDs DO aux DB 2 n OV POW swp APL Config 3 config 4 9 lt ONE E Q 5 O 6 INK LAN1 L 7 8 SE Of
95. re live A fo Electrostatic Sensitive Device The gateway is sensitive to electrostatic discharge which can cause internal damage and affect its normal operation Therefore adhere to the necessary safety precautions for components that are vulnerable to electrostatic discharge when you install or handle the gateway gt Donot touch the metal pins of the connectors of the gateway gt Touch a grounded object to discharge potential static gt Wear an approved grounding wrist strap gt If available use a static safe workstation gt When not in use store the device in an appropriate static safe packaging SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Installing gateway 35 112 7 2 Mounting gateway No tools are required for mounting the EU5C SWD ETHERCAT Gateway onto a top hat rail The back of the gateway 1 carries a spring fitted bolt 2 by which the gateway can be clamped to the rail 3 eet ararayayny say Tee N ae Minow ow Figure 3 Mounting principle of the gateway 7 2 1 Mounting gateway onto top hat rail To mount the gateway onto the top hat rail proceed as follows WARNING Electrical shock Make sure that the gateway is disconnected from any power supply Cover or enclose neighboring units that are live gt Tilt the gateway slightly and hook it into the upper railing from above thereby pushing down
96. rrectly The configuration and installation of the SmartWire DT network must also have been carried out correctly with all slaves connected Commissioning takes place in several steps 1 Putting the SmartWire DT network into operation 2 Create a connection to the PROFINET IO network 3 3 Configure PROFINET IO network and load configuration to PLC PROFINET IO Controller 4 Write code for controller program and load it to PLC PROFINET IO Controller DANGER Danger of lethal injuries by unexpected starting up of motors or machinery If you have already integrated devices into a system secure the operating range of any connected parts of the system against access so that nobody is endangered by motors or machinery starting up unexpectedly 8 1 Configuring SmartWire DT network in gateway Before the gateway can exchange data with the PLC a valid SmartWire DT network configuration a so called gateway target configuration has to be stored in the gateway This is compared with the current configuration actual configuration each time the gateway is restarted If the gateway ascertains in this process that a SmartWire DT slave cannot be reached or a wrong slave type is determined the SmartWire DT network will not go into operation to be precise this is dependent on the network configuration Reading of the SmartWire DT network configuration takes place by pressing the configuration button on the gateway for the position
97. rtWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Commissioning gateway 86 112 The Browse Network dialog box closes and the current address parameter of the gateway are taken over into the Edit Ethernet Node dialog box Edit Ethernet Node Ethernet node Nodes accessible online MAC address 00 02 42 24 D 8 E1 Set IP configuration Use IP parameters Gateway IP address Are 10 11 01 f Do not use router Subnet mask 255 255 0 0 Use router fi 4 i C Obtain IP address from a DHCP server Identified by ie ig bd Client ID Assign IP Configuration Assign device name Device name leu c swd 03 Assign Name Reset to factory settings Reset Close Help Figure 53 Edit Ethernet Node 2 gt If you want to change the IP Address Enter the appropriate values in the IP address and Subnet mask fields then click Assign IP Configuration button gt The IP address is transferred to the gateway and is stored in the gateway gt If you want to change the device name Enter the new name in the Device name field then click Assign name button SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Commissioning gateway 87 112 The device name is transferred to the gateway and is stored in the gateway gt
98. s Note gt The GSDML device description file contains only I O information for SmartWire DT slaves which were listed as sales products at the time of creation of the file Eaton SWD Assist planning software In principle you can build up and configure a SmartWire DT network without any software tools However it is recommended to use the SWD Assist software to plan dimension and document the SmartWire DT network In SWD Assist a project specific GSDML file can be created and exported Using this file gives you the benefit of finding the I O modules of the SmartWire DT slaves already preconfigured in your PROFINET controller engineering tool For further information please refer to the SWD Assist online help SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Description of the EU5C SWD PROFINET gateway 23 112 Note gt You will find the Eaton SWD Assist software on the product DVD which is included in the EU5C SWD SW software package order number 3233 920 available from Hilscher You can use the wizard on the product DVD to download updates of the Eaton SWD Assist software or you can download SWD Assist directly from the www moeller net website under Support gt Download Center Direct link http downloadcenter moeller net de software a487d8b7 da91 486f b3ba a7ca2035db99 3 3 Interfaces The gateway features a SmartWire
99. s Unlatching the emergency stop devices must not cause restart e You must take safety precautions emergency switching off in the external circuitry of the gateway and any power modules type EU5C SWD PF1 1 or EU5C SWDPF2 1 that are used To do so plan to switch off the power supply to the contactor coils AUX e Measures should be taken to ensure the proper restart of programs interrupted after a voltage dip or failure This should not cause dangerous operating states even for a short time If necessary emergency stop devices should be implemented e Wherever faults in the automation system may cause damage to persons or property external measures must be implemented to ensure a safe operating state in the event of a fault or malfunction for example by means of separate limit switches mechanical interlocks etc SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Safety 18 112 2 6 Safety instructions to avoid property damage To avoid damage to your gateway or your communication system you must read understand and follow the following safety instructions and all safety instructions and warnings in this manual concerning property damage before you install and operate the gateway 2 6 1 General safety instructions concerning supply voltage In safety relevant applications the power supply providing power to the SmartWire DT system must fea
100. s follows Notes a gt Note lt important note gt Note lt simple note gt lt note where to find further information gt Operation instructions 1 lt operational step gt gt lt instruction gt 2 lt operational step gt gt lt instruction gt Results 2 lt intermediate result gt gt lt final result gt For a description of the labeling of Safety Messages see section Labeling of safety messages page 20 SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Introduction 7 112 1 2 Versions of devices firmware software drivers and device description file The hardware revisions and software versions functionally belong together This means that certain revisions of the hardware of the gateway need certain versions of firmware software and drivers in order to function properly This section lists the hardware revisions and the versions of the firmware the configuration software the drivers and the device description file which functionally belong together and to which all instructions in this manual refer Device and firmware This manual refers to the following hardware revision and firmware version of the EU5C SWD PROFINET gateway Device type name Protocol Part number Hardware Firmware revision version EU5C SWD PROFINET _ PROFINET IO Device 9233 920 E030D0UO nxf Table 2 Reference to har
101. sage will be displayed on the web page If the file passes a Transfer succeeded message will be displayed Note gt After successful transfer you need to reset the gateway in order to start up the new firmware SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Updating firmware 99 112 10 4 Resetting gateway gt Inthe address bar of your browser enter URL http lt IP address gt reset gt Ifthe user authentication dialog opens enter user name admin and password admin The following web page opens Device Reset Firmware is being restarted and connections may be interrupted or time out Ethernet connection may be lost if IP parameters are not stored permanently O0 Please confirm you want to reset the device Figure 58 Reset by HTTP as depicted in Internet Explorer Important Please note the following consequences of a reset The firmware is being restarted and connections will be interrupted or timed out I O bus communication is being stopped The IP connection gets lost if the gateway is not connected to a PROFINET IO controller and the IP address has not been permanently stored in the gateway gt Activate the checkbox in front of Please confirm to acknowledge that you want to reset the device gt Then click Submit button to start the reset You can use the Cancel button to uncheck the checkb
102. scher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Commissioning gateway 64 112 gt Inthe Value column click the entry you want to change As soon as you click a value a drop down list opens in which you can select other values You can set the following parameters Baudrate SmartWire DT 125 kBit s The Baud rate of the SmartWire DT Network 250 kBit s Compatible devices allowed No The planned SmartWire DT slaves in the PROFINET IO configuration must comply 100 with the SmartWire DT slaves of the stored gateway target configuration If not no data interchange takes place with the PROFINET IO controller Yes Data exchange takes place if the connected SmartWire DT slaves are different but compatible with the planned SmartWire DT slaves in the PROFINET IO configuration This is indicated by the Config LED on the gateway All slaves optional Defined for each slave Specification is performed individually for each SmartWire DT slave Yes Data transmission to the PROFINET IO also takes place for a random number of failed SmartWire DT slaves The setting in the module parameters of the SmartWire DT slaves has no effect See table Application Parameters of Slave in the following section Delay between cyclic Reserved option other settings currently not exchange ms supported Table 22 Application parameters of gateway gt Click OK button to close the Properties sheet SmartWire
103. scher com c 9233 920 J on Version of firmware at time of delivery Information on power supply for switching devices AUX Information on power supply for Gateway and Smart Wire DT slaves POW Information on wire gauge of power supplies Operating ambient temperature Device type name Part number Hardware revision number Serial number Table 17 Device type label EUS5C SWD PROFINET Note The version of the loaded firmware is indicated on the device type label only since version 1 4 x x Older gateways do not carry this information on the label SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Getting started 33 112 6 Getting started The following table provides an overview of the steps necessary for installing and commissioning the EU5C SWD PROFINET gateway Note gt The gateway is shipped with its firmware already loaded If your gateway is running with a firmware version older than 1 4 x x it is strongly recommended to update the firmware and to use the version of the device description file specified in section Versions of devices firmware software drivers and device description file page For information on how to update the firmware of the gateway please refer to chapter Updating firmware gt page 95 install gateway Connect gateway to PROFINET IO network Section Connecting PROFINET IO
104. ses unless they are required in accordance with the law and cannot be limited Warranty claims are limited to the right to claim rectification SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Introduction 15 112 12020 Export regulations The delivered product including the technical data is subject to export or import laws as well as the associated regulations of different counters in particular those of Germany and the USA The software may not be exported to countries where this is prohibited by the United States Export Administration Act and its additional provisions You are obligated to comply with the regulations at your personal responsibility We wish to inform you that you may require permission from state authorities to export re export or import the product 1 5 6 Registered trademarks Adobe Reader is a registered trademark of the Adobe Systems Incorporated PROFINET is a registered trademark of PROFIBUS amp PROFINET International PI Karlsruhe SmartWire DT is a registered trademark of Eaton Corporation S7 S7 300 and S7 400 are registered trademarks of Siemens AG Berlin and Munich STEP 7 is a registered trademark of Siemens AG Berlin and Munich Windows XP Windows Vista Windows 7 and Windows 8 are registered trademarks of Microsoft Corporation All other mentioned trademarks are property of the
105. sh 2015 06 Released Public Firmware recovery via HTTP 102 112 2 Check IP address gt Inthe Windows Start menu of your configuration PC select All Programs gt Hilscher GmbH gt Ethernet Device Configuration to start the Ethernet Device Configuration Tool gt The Ethernet Device Configuration tool opens gt Ethernet Device Configuration ba a a File Options Devices Online Find next previous Search Devices j Figure 59 Ethernet Device Configuration Tool gt Click Search Devices button to start searching for the gateway within the local Ethernet network dv The tool starts scanning for devices and lists all found Hilscher devices and their IP addresses Fy Ethernet Device Configuration Datei Optionen Devices Online 00 02 A2 2D 53 9B Backup FW Backup FW SN 00020001 ID 0x 10 11 5 24 I Figure 60 Found gateway in Ethernet Device Configuration Tool gt Note or write down the IP address Note gt If the default IP address 0 0 0 0 is displayed the gateway has not yet received an IP address from a DHCP server Make sure that the gateway is connected to a subnet with an active DHCP server Then restart the gateway by briefly disconnecting the voltage supply while the Ethernet cable remains plugged in Wait a few seconds after reconnecting the voltage supply then click the Search Devices button in the Ethernet Device Configuration Tool again SmartWire DT Gateway EU5
106. t number e Name of loaded firmware e Firmware version e Date of firmware The Firmware Update section features the following control elements Control element Function SS Selection field Shows selected file and its location Transfer Uploads selected firmware file to device Cancel Cancels firmware update and clears selection field Table 28 Controls in firmware update page Opens the file selection dialog SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Updating firmware 98 112 gt Click Browse button to open a dialog box for selecting the firmware file gt Select the firmware file and close the dialog box Note The filename extension of firmware files is nxf Path and name of the selected file are displayed in the field next to the Browse button gt Click Transfer button to load the new firmware file to the gateway Hazard of device damage by disruption of voltage supply during firmware update Do not interrupt the voltage supply while updating the firmware of the gateway Power failure during a writing process in the file system can cause severe malfunctioning of the device gt After you have started the upload by clicking the Transfer button the validity of the firmware file is being checked by the system If the file fails the validity check the file will not be stored in the gateway and an error mes
107. ta EU5C SWD PROFINET gateway SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Technical data 108 112 12 2 Technical data PROFINET IO Device Slave Maximum number of cyclic input data 800 bytes Maximum number of cyclic output data 642 bytes Maximum number of cyclic input output 1000 bytes data in sum Supported protocols RTC Real Time Cyclic Protocol Class 1 and 2 unsynchronized RTA Real Time Acyclic Protocol DCP Discovery and configuration Protocol CL RPC Connectionless Remote Procedure Call LLDP Link Layer Discovery Protocol SNMP Simple Network Management Protocol Baud rate 100 MBit s Data transport layer Ethernet Il IEEE 802 3 Ethernet Switching Cut through Limitations RT over UDP not supported Multicast communication not supported DHCP is not supported RT Class 2 synchronized IRT flex is not supported RT Class 3 synchronized not supported FastStartUp is not supported Media Redundancy except MRP client is not supported Access to the submodule granular status bytes IOCS is not supported The amount of configured IO data influences the minimum cycle time that can be reached Supervisor AR is not supported Supervisor DA AR is supported Only 1 Input CR and 1 Output CR are supported Multiple WriteRequests are not supported Table 30 Technical data PROFINET IO RT Device protocol SmartWire DT Gat
108. taining the device description files menu Open Electronic Device Description Files Directory SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Introduction 11 112 1 3 4 Notes on installing the USB Driver If you intend to use the SWD Assist software you should first install the USB driver on your PC before you connect the gateway via USB To install the USB driver from the DVD choose Install Planning and Configuration Tools in the DVD menu to open the installation wizard and then select the USB driver option As an alternative you can use the Windows Explorer to open the Setups amp Drivers USB Driver folder on the DVD and then double click the setup exe file Just follow the instructions of the installation routine afterwards p Note gt Under Windows XP the installation process is not yet finished by the setup The installation process has to be completed in the Found new Hardware Wizard which automatically opens when you connect the gateway to aPC via USB cable for the first time see below Windows XP When you connect the gateway via USB for the first time to a PC running under Windows XP the Found New Hardware Wizard opens gt Answer the question Can Windows connect to Windows Update with No not this time Then click Next button gt If you have already carried out the setup of the USB driver as recommended yo
109. ter the name of the table e g VAT_ 1 then click OK button gt The new variable table is displayed in the Blocks node of the project window SmartWire project C Programme Siemens Step s proj SmartWir ey a System data io 0B1 ia DB100 SIMATIC 300 1 CPU 315 2 PN DP E 57 Program 1 By Sources obs Figure 46 Variable Table Created 6 Edit Variable Table gt Select the variable table gt Double click the variable table or choose Edit gt Open Object in the menu bar SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Commissioning gateway 80 112 gt The variable table is opened in the editor Ka Var VAT_1 Table Edit Insert PLC Variable View Options Window Help gt Dell S selje x Sala Darla wa et VAT_1 SmartWire project SIMA TIC saa ie 315 2 PN DP S7 Program 1 2 0000_0000 Press Fi for help offline Abs lt 5 2 A Figure 47 Edit Variable Table gt Fill in the Address and Display format columns as shown in the picture above gt Inthe menu bar of the editor choose Table gt Save 7 Display I O data gt Inthe menu bar of the editor choose Variable gt Monitor or click Ga button in the toolbar of the editor gt An online connection to the S7 300 PLC of this project is automatically established and signals currently sent by the SmartWire DT slave are
110. the gateway with slight force in order to overcome the resistance of the spring in the bolt Hook gateway to upper railing SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMO7EN Revision 7 English 2015 06 Released Public Installing gateway 36 112 gt Keep on pushing the gateway downwards and tilt it back into vertical position thereby hooking the gateway into the lower railing 5 Hook gateway to lower railing gt Let go of the gateway The spring inside the bolt automatically pushes the gateway upwards into the railings thereby fixing the gateway to the top 3 hat rail Gateway is clamped to top hat rail SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Installing gateway 37 112 1 2 2 Removing gateway from top hat rail To remove the gateway from the top hat rail proceed as follows WARNING Electrical shock Make sure that the gateway is disconnected from any power supply Cover or enclose neighboring units that are live gt Push down the gateway with slight force to overcome the resistance of the spring in the bolt then unhook the gateway first from the lower railing and then from the upper railing Unhook gateway SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMO7EN Revision 7 English 2015 06 Released Public Installing gateway
111. tion block and load them to the PLC Then you can visualize input and output data of the M22 SWD K22LED B slave in STEP 7 by means of a variable table and send output data to the slave too Prerequisites e You have already created configured and loaded onto the S7 300 PLC a project containing a certain SmartWire DT slave in this case the M22 SWD K22LED B function element e Communication between PROFINET IO and SmartWire DT network via gateway runs smoothly cyclic data is exchanged e The programming device PC with installed STEP 7 software is connected to the S7 300 PLC e You know the meaning of the input and output signals e g the assignment of certain Bits to certain operational states of the concerned SmartWire DT slave needed for programming in the corresponding user manual of the device e g in the Eaton user manual SmartWire DT Units MNO5006001Z EN You will find the parameters of individual SmartWire DT devices e The project is opened in the SIMATIC Manager Step by step instructions 1 Create data block gt Inthe project tree select the CPU gt Inthe menu bar choose Insert gt S7 Block gt Data block SmartWire project C Programme Siemens Step s proj SmartWir EQ Smartwire project Em S7 Program 1 Connections SIMATIC 300 1 9 GEES s7 57 Program 1 Figure 38 Project Window in SIMATIC Manager SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012
112. ture a PELV power feed module protective extra low voltage Switch off the power supply if you are reconnecting slaves in the SmartWire DT system or reconnecting the ribbon cable connection Otherwise the SmartWire DT slaves can be destroyed The gateway has protection against polarity reversal for the 24 V DC POW supply However if the gateway is connected via the serial interface to an earthed device for example to a PC the gateway can be destroyed if the polarity of the power supply is reversed The functional earth FE must be connected to the protective earth PE or to the potential equalization The system installer is responsible for implementing this connection Connecting cables and signal lines should be installed so that inductive or capacitive interference does not impair the automation functions Suitable safety hardware and software measures should be implemented for the I O interface so that a line or wire breakage on the signal side does not result in undefined states in the automation devices 2 6 2 Device destruction by exceeding allowed supply voltage The gateway must only be operated with the specified supply voltage Make sure that the limits of the allowed range for the supply voltage are not exceeded A supply voltage above the upper limit can cause severe damage of the gateway A supply voltage below the lower limit can cause malfunction of the gateway Ensure a reliable electrical isolation of the
113. u can ignore the wizard s request to insert a CD or floppy disk Answer the What do you want the wizard to do question by selecting the Install the software automatically option then click Next button gt After the installation is complete click Finish button Windows 7 and 8 The USB connection is instantly operative under Windows 7 and 8 if you have carried out the setup of the USB driver before first connecting the USB cable as recommended Uninstall USB Driver If you want to remove the USB driver from a PC running under Windows XP choose Start menu gt Control Panel gt Add or Remove Programs then select Windows Driver Package Hilscher GmbH hilusbser Ports entry Click Change Remove button to uninstall the driver Under Windows 7 and 8 choose Start menu gt Control Panel gt Uninstall a program then select Windows Driver Package Hilscher GmbH hilusbser Ports entry Click Uninstall Change button to uninstall the driver SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Introduction 12 112 1 4 Documentation overview Besides this user manual at hand path on product DVD Documentation english 2 Hardware EU5C SWD PROFINET UM xx EN pdf the following documents are also relevant for the user of the EU5C SWD PROFINET gateway SmartWire DT Information on MNO05006001Z EN Documentation english Units engineeri
114. umbers in picture amp off Gateway has no connection to Ethernet 7 amp 9 RX TX RJ45 LED gelb Ch0 amp Ch1 amp 30 Steady on or Gateway sends receives Ethernet frames Numbers in flashing yellow picture 8 amp 10 Table 15 Description of the LEDs 2 SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Device picture connectors and LEDs 31 112 9 3 Pinning of the Real Time Ethernet interface The following picture shows the pinning of the PROFINET interface of the gateway PIN 1 TX PIN 2 TX 3 RX i TERM Ethernet E TERM Channel 0 5 RX 7 TERM TERM TX gt TX 3 RX Ethernet eas Channel 1 amp TERM RX TERM TERM Bob Smith Termination Bob Smith Termination Table 16 Ethernet interface channel 0 and channel 1 pin assignment RJ45 p Note gt The Ethernet interface supports auto crossover SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Device picture connectors and LEDs 9 4 Device type label 32 112 Each EU5C SWD PROFINET Gateway carries a device type label which provides the following information O Version 1 4 2 0 Doc 24V AUX max 3A DC 24V POW max 0 6A AWG 24 16 CE Onl Operating amb temp 25 55 C SE L EU5C SWD PROFINET Kiar www hil
115. uration Tool on your configuration PC included on the product DVD in order to read out the newly assigned IP address from the gateway The tool uses the netIDENT protocol to search for all Hilscher devices within the connected IP network and then lists all found devices and their IP addresses Note gt This chapter describes only how to download the recovery firmware Instructions on how to configure and operate a DHCP server are not subject of this manual For information on using a DHCP server please consult your local network administrator SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Firmware recovery via HTTP 101 112 11 2 Prerequisites The gateway is supplied with voltage and the backup firmware inside the device is running this is indicated by steady green light at the POW LED The gateway is disconnected from the PROFINET network The gateway is connected to an active DHCP server via local Ethernet network The gateway is connected via local Ethernet network to a configuration PC with installed standard web browser You have access to the firmware file which you want to download to the gateway the firmware is stored on the SmartWire DT Gateway Solutions product DVD in the Firmware EU5C SWD PROFINET Vx x x x folder You know the IP address which the DHCP server has assigned to the gateway If not install the
116. uration is stored retentively as gateway target configuration Hazard of device damage by disruption of voltage supply while creating target configuration Do not interrupt the voltage supply while creating the target configuration of the gateway Power failure during a writing process in the file system can Cause severe malfunctioning of the device gt The gateway then restarts 8 1 2 Switching on gateway when target configuration is stored If a configuration is stored in the gateway each time the supply voltage is switched on it is checked whether the slaves actually found on the network comply with the stored gateway target configuration The result of the check is indicated by the SmartWire DT status LED on the gateway for the position of the LED see section Positions of the LEDs page 23 SWDStatus Duo LED _ orange red green at the same time SmartWire DT green The current actual configuration complies with the gateway target Number in configuration Data exchange between gateway and SmartWire DT picture 4 slaves takes place Flashing red Anecessary SmartWire DT slave is missing or the gateway target configuration does not comply with the actual configuration Nodata exchange between gateway and SmartWire DT slaves between gateway and SmartWire DT slaves red Short circuit on the 15 V power supply or no SmartWire DT slave is connected Nodata exchange between gateway and SmartWire DT 26 gree
117. ver to assign an IP address to the gateway in order to perform a firmware download see chapter Firmware recovery via HTTP gt page 100 SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UM07EN Revision 7 English 2015 06 Released Public Updating firmware 97 112 e STEP7 For further information please refer to section Using STEP 7 to Assign Device Name or IP Address on the Gateway gt page 83 10 3 Step by step instructions for updating firmware gt Start your web browser gt Inthe address bar of your browser enter URL http lt IP address gt fwupdate gt The user authentication dialog opens gt Enter user name adminand password admin Note gt The current version of the firmware does not provide options to customize the user authentication of the web server by creating own groups users or passwords The following web page opens Firmware Firmware Identification Channel Name Version Date 0 SmartWire DT PROFINET 0 9 4 1 9 5 2012 Firmware Update Choose the new firmware file nxf you want to install Browse Submit your file by clicking on transfer The transfer will take a few seconds WARNING Do not interrupt power or disconnect cable from the system while the transfer is in progress Figure 57 Firmware update by HTTP as depicted in Internet Explorer The Firmware Identification section displays the following information e Channel number por
118. y a SmartWire DT slave is forwarded to the PROFINET IO controller by the gateway using the following parameters Parameter Value Slot Slot 0 gateway reports Slot 1 99 individual SmartWire DT slaves SubSio Channel Number 0x8000 Submodule Channel Property ChannelErrorType conveys the SmartWire DT diagnosis code see subsequent table Table 26 Diagnosis parameters SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public PROFINET IO data communication 94 112 ChannelErrorType mapping of the SmartWire DT diagnosis code in PROFINET IO PROFINET IO SmartWire DT ChannelErrorType Diagnosis code foi TSmartWire DTis im state failsafe O gatoway individual SWD slaves 0x0007 0x17 Out of range high reading on at least one temperature input 0x0008 Out of range low reading on at least one temperature input in the middle position for longer than four seconds No unambiguous position of the 1 0 A switch auto manual switch for more than four seconds Table 27 Diagnosis ChannelErrorType SmartWire DT diagnosis code 2 0x19 Please note the following SmartWire DT diagnosis codes from 0x01 to 0x18 are mapped to ChannelErrorType values according to the table above SmartWire DT diagnosis codes from 0x19 and higher are mapped to the ChannelErrorType values according to the following scheme The first byte of the ChannelErr
119. y reversal Rated operational current 111 mA with two participants Heat dissipation at 24 V DC 2 66 W with two participants Potential isolation between Upow and No 15 V SmartWire DT supply voltage Bridging voltage dips 10 ms n Repeat rate lt D 02 Status display 15933 0 7A Note If contactors with a total power consumption gt 0 7 A are connected a power feeder module EU5C SWD PF2 has to be used SmartWire DT supply voltage Rated operational voltage U max current lt D e9 Short circuit strength Connection supply voltages Connection type Push in terminals solid 0 2 1 5 mm AWG 24 16 0 25 1 5 mm SmartWire DT master SWD 80P RS485 Flexible with ferrule SmartWire DT network Participant type SmartWire DT Master ASIC Number of SmartWire DT slaves 125 250 kBd Automatic SmartWire DT master SWD LED duo color red green Configuration Config LED duo color red green Baud rate Address setting Status display Connections Plug 8 pole Blade terminal SWD4 8MF2 Plug connectors SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Technical data 107 112 Supported Address setting Automatically via PROFINET IO Status display PROFINET IO device APL SF BF LEDs duo color red green Connector socket 2 x RJ45 Connector plug RJ45 Table 29 Technical da
120. your PROFINET IO project you must save and compile the configuration before you can upload it to your PROFINET IO controller i e your S7 300 PLC gt Inthe menu bar of the HW Config window choose Station gt Save and Compile gt The hardware configuration is saved and compiled SmartWire DT Gateway EU5C SWD PROFINET Hilscher 2012 2015 DOC120304UMOTEN Revision 7 English 2015 06 Released Public Commissioning gateway 70 112 8 39 Step by step instructions for loading PROFINET IO configuration to S7 300 PLC Prerequisites e The S 7 300 PLC is connected to power supply e The S 300 PLC is connected to the programming device PC with installed STEP 7 software Step by step instructions 1 Set up PG PC interface in STEP 7 gt Inthe menu bar of the SIMATIC Manager on your programming device PC choose Options gt Set PG PC Interface The Set PG PC Interface dialog box opens Set PG PC Interface Access Path LLDP DCP Access Point of the Application UNLINE SIEF f TLR YIF auto Standard for STEP 7 Interface Parameter Assignment Used TCP IP Auto gt Intel R 82566DM 2 Gig EA TCPAP gt NdisWanlp lt Active gt A TCPYIP gt VMware Virtual E theme TCP IP gt VMware Virtual Etherne Copy gt TCP IP Auto gt Intel R 82566DM gt Assigning Parameters for the IE PG access to your NDIS CPs with TCP IP Protocol AFC 1006 Interfaces
121. zed but the communication on SmartWire DT is not off 0 5 s on in cyclic data exchange 0 5 s off 0 5 s Gateway is initialized but the configuration for the communication protocol on PROFINET is missing or in error Flashing 2 s Gateway is initialized but the configuration for the communication off 0 5 s on protocol on SmartWire DT is missing or in error 0 5 s off 0 5 s Gateway has detected an error during the initialization Missing configuration error in configuration or internal error Table 20 APL LED Prerequisite for data interchange is that the PROFINET configuration drawn up in the PROFINET engineering tool planned configuration complies with the target configuration actually available on the gateway The result of this check is signaled on the gateway by the SmartWire DT configuration LED Config Configuration The planned configuration complies with the gateway target status configuration Data exchange between Gateway and PLC via Number in PROFINET takes place picture 3 w The planned configuration does not comply with the gateway target configuration but is compatible with it Data exchange between gateway and PLC via PROFINET takes place red On The planned configuration and the gateway target configuration are not compatible Nodata exchange between gateway and PLC via PROFINET off Off No communication with the PROFINET IO controller or the gateway does not contain a project configur