1. Ar ibridge E1 amp V 35 Fiber Modem User Manual V1 0 4 3 Front panel of chassis V 35 Fiber modem E1 Fiber modem D p PKO O PWR POKO O PWR wO O Test LPO O TERT NOPO O LINK NoP O C Los LOF RxD RD O O AS IB O OTD mo O cv 1no SCA WwuoozL U e XL XL D D Figure3 Panel of the Module T Er ibridge E1 amp V 35 Fiber Modem User Manual V1 0 4 4 LED Description Table 1 LED Description LED Color Status Function Description ON Power OK PWR Green OFF Power off or failed ON Local optical signal loss NOP Red BLINK Remote optical signal loss OFF No optical signal loss ON Local Optical Line lose synchronization LOF Red BLINK Remote Optical Line lose synchronization OFF No Optical Line LOF Local optical line s bit error rates is over ON 10 IE 6 Red Remote optical line s bit error rates is BLINK p over 10 OFF No Optical Line IE 6 ON Local E1 signal loss ELOS Red BLINK Remote E1 signal loss OFF No E1 LOS ON Local AIS AIS Red BLINK Remote AIS OFF No E1 AIS ON Local E1 code invalid CV Red BLINK Remote E1 code invalid OFF No code invalid VLINK Green ON V 35 port linked Ro Zi Fibridge E1 amp V 35 Fiber Modem User Manual V1 0 OFF V 35 po
2. line B 11 XTCB DTE transmit clock B 12 TCB Transmit clock line B 14 TDB Transmit data line B 15 TCA Transmit clock line A 16 RDB Receive data line B 17 RCA Receive clock line A 20 DTR DTE Prepare for receiving data 24 XTCA DTE transmit clock A Others N A 3 4 Size Standalone 252 Width x 136 Depth X 36 Height Module 220 Length X 176 Width x 25 3 Height 16 slot chassis 441 Width x 340 Depth X 180 Height 3 5 Power Power supply AC Power 100V 240V 0 4 0 2A 50 60 Hz DC Power 48V 0 4A Power consumption lt 2W Er ibridge E1 amp V 35 Fiber Modem User Manual V1 0 3 6 Environment Operation Temperature 0 C 50 C Humidity 096 9096 25 C non condensed Transport and store Temperature 20 C 60 C Humidity 096 9096 25 C non condensed ZF ibridge E1 amp V 35 Fiber Modem User Manual V1 0 4 Appearance 4 1 Front panel of standalone 2029229090898 E17V 35 OPTICAL CONVERTER DIP Switch LEDs Figure1 Front Panel of the Standalone 4 2 Back panel of standalone POWER v35 EICHANNEL ON TX RX OFF J our IN AC Power Supply V 35 Port El Port Optical Port DC Power Supply 44vDC E1CHANNEL ON v3 um u Po RJ OFF PGND OV 48V OUT IN 4200hm uzax sg Figure2 Back Panel of the Standalone
3. pair of F4 56 device One named A the other named B For setting B s timeslot following A you should set the SET DIP SWITCH as follows Bit 1 2 3 4 5 6 7 8 A OFF OFF OFF OFF OFF X1 ON OFF B OFF OFF OFF X2 OFF X1 ON ON X1 lies on the router for X2 both ON and OFF are OK Table3 E1 Fiber Modem Timing Source Selection ON DIP SWITCH SET SW5 Description Timing Source BIT7 BIT8 Internal OSC ON ON For Ei ead i Recovered from BRE ON Framed Mode Eck Recovered from ON OFF optical clock For E1 used in Recovered from OFF OFF unframed mode E1 Clock 10 Er ibridge E1 amp V 35 Fiber Modem User Manual V1 0 Table4 V 35 Fiber Modem Timing Source Selection ON DIP SWITCH SET SW5 Timing Source BIT7 BIT8 Internal OSC ON ON Recovered from optical clock ON OFF V 35 DTE Clock OFF OFF N A OFF ON Table5 Time slot Setting DIP Switch TS0 TS31 Function ON OFF TSO Time slot 0 Available Not Available TS1 Time slot 1 Available Not Available TS2 Time slot 2 Available Not Available TS3 Time slot 3 Available Not Available TS4 Time slot 4 Available Not Available TS5 Time slot 5 Available Not Available TS6 Time slot 6 Available Not Available TS7 Time slot 7 Available Not Available TS8 Time slot 8 Available Not Available TS9 Time slot 9 Available
4. Modem User Manual V1 0 1 Overview E1 Fiber Modem or V 35 Fiber Modem can convert G 703 E1 signal or V 35 signal to single mode or multimode fiber which extend the transmitting distance greatly E1 signal support framed and unframed mode When in framed mode continuous or discontinuous time slot can be selected E1 fiber modem and V 35 fiber modem can work together Both of them are widely used in extending user interface in ATM or DDN 2 Features e Fully compatible with ITU T G 703 G 704 G 823 V 35 recommendation e Standalone and module available support hot swap e Framed N 64Kbps and unframed 2 048Mbps optional e Frame mode support PCM30 PCM31 e CRC non CRC auto negotiation on E1 interface e Support internal clock E1 recovery clock optical line clock or V 35 line clock e Provide local loop back test functional diagnostic loop back test and remote loop back test e For V 35 interface at receive side clock is reversed and Er ibridge E1 amp V 35 Fiber Modem User Manual V1 0 non reversed auto negotiation while at transmission side clock can be configured as reversed or non reversed e For E1 interface 75 ohm unbalanced and 120 ohm balanced available and auto negotiation e Comprehensive LED indicators on front panel convenient for the diagnosis of equipment working state e 48VDC or 220VAC power supply selectable e 16 slot 4U height elaborate cooling design and two redundant power supp
5. Not Available TS10 Time slot 10 Available Not Available TS11 Time slot 11 Available Not Available TS12 Time slot 12 Available Not Available 11 ZJF ibridge E1 amp V 35 Fiber Modem User Manual V1 0 TS13 Time slot 13 Available Not Available TS14 Time slot 14 Available Not Available TS15 Time slot 15 Available Not Available TS16 Time slot 16 Available Not Available TS17 Time slot 17 Available Not Available TS18 Time slot 18 Available Not Available TS19 Time slot 19 Available Not Available TS20 Time slot 20 Available Not Available TS21 Time slot 21 Available Not Available TS22 Time slot 22 Available Not Available TS23 Time slot 23 Available Not Available TS24 Time slot 24 Available Not Available TS25 Time slot 25 Available Not Available TS26 Time slot 26 Available Not Available TS27 Time slot 27 Available Not Available TS28 Time slot 28 Available Not Available TS29 Time slot 29 Available Not Available TS30 Time slot 30 Available Not Available TS31 Time slot 31 Available Not Available Notice a If you want to make the converter work under unframed mode you should set TSO to TS31 all to ON or OFF b Under framed PCM30 mode TS16 of E1 channel is used to carry command instead of payload TSO and TS16 should be set OFF and the most bandwidth is 1920Kbps ew e Er ibridge E1 amp V 35 Fiber Modem User Manual V1 0 5 Typical Applica
6. agnostic loop back Set bit 7 and bit 8 of SET SW5 on remote end ON which means remote end is the timing source Set bit 7 ON and bit 8 OFF of local SET SW5 which means local end follows the Fiber port timing If diagnostic loop back successful LOS LED on local and remote end should be off TXD amp RXD LEDs on local end should blink For V 35 fiber modem VLINK of on local end should be on under diagnostic loop back 15 Er ibridge E1 amp V 35 Fiber Modem User Manual V1 0 6 3 Remote Loop Back Setting 1 V 35 Fiber E1JV 35 E1 V 35 Tester As the picture above set E1 or V 35 fiber modem working in framed mode Set bit 1 of SET SW5 on local end ON to perform remote loop back Set bit 7 and bit 8 of SET SW5 on local end ON which means remote end is the timing source Set bit 7 ON and bit 8 OFF of remote SET SW5 which means local end follows the Fiber port timing If remote loop back successful LOS LED on local and remote end should be off TXD amp RXD LEDs on local end should blink For V 35 fiber modem VLINK of on local end should be on under remote loop back 16 Er ibridge E1 amp V 35 Fiber Modem User Manual V1 0 7 Order Information 7 1 Model F9 480 E1 Optical Multiplexer For more detailed order information please check the Part Number 7 2 Part Number P N F9 E1abbcde E1 Fiber Modem F9 V35abbcde V 35 Fiber Modem E1 amp V 35 Modem E1 interface amp V 35
7. interface optional F9 E1V35abbcde FC 416 a ee chassis with abbcd represents fiber parameter separately as follows a Optical port type S Single mode M Multimode W Single strand bb Optical port transmission distance 02 20Km 04 40Km 06 60Km 08 80Km 10 100Km 12 120Km c Wavelength em A r ibridge E1 amp V 35 Fiber Modem User Manual V1 0 1 850nm 2 1310nm 3 1550nm d Connector type F FC C SC T ST e Power input type A 220VAC D 48VDC We Reserve the right to vary descriptions and specifications without notice due to Fibridge s policy of continuous product improvement 18
8. ly chassis available 3 Specification 3 1 E1 interface e Compliant with G703 G 704 e Code type HDB3 e Data rate 2 048Mbps or n 64Kbps n 1 31 e Line impedance 75 9 Unbalanced 120 9 Balanced e Interface connector BNC 75 9 RJ45 120 9 e Jitter performance Compliant with ITU T G 742 and G 823 e Frame mode Framed Unframed optional Definition of RJ45 connector 1202 E1 balanced PIN 1 2 4 5 3 6 Others Definition RX RX TX TX GND Reserved A r ibridge E1 amp V 35 Fiber Modem User Manual V1 0 3 2 Optical interface Line code type 1B1C Bit rate 4 096Mbps Wavelength MM 850 1310nm optional SM 1310 1550nm optional Connector FC SC ST optional Transmission distance MM 0 2Km SM 0 120Km 3 3 V 35 Interface Data rate 2 048Mbps or n 64Kbps n 1 31 Jitter performance Compliant with ITU T V 35 standard Connector DB25 female jack Operation mode DTE DCE optional Definition of V 35 interface DB25 pins No Definition Description GND Ground TDA Transmit data line A RDA Receive data line A RTS DTE ask for transmitting data CTS DCE clear the transmitting DSR DCE ask for transmitting data NIOIAJ AJOIN GND Ground 3 Zi Fibridge E1 amp V 35 Fiber Modem User Manual V1 0 8 DCD DCE transmit carrier wave signal 9 RCB Receive clock
9. rt not linked BLINK Receiving data from V 35 or E1 channel RXD Yellow OFF No data from V 35 or E1 channel BLINK Transmitting data from V 35 or E1 TXD Yellow channel OFF No data from V 35 or E1 channel ON Test enabled and loop successful TEST Yellow BLINK Test enabled but loop unsuccessful OFF Test disabled ON Local Diagnostic loop back or the remote device set remote loop LOOP Yellow ELE Remote loop back or the remote device set diagnostic loop OFF Normal operation ON No bit error PTOK Yellow If test enabled it means bit errors and no id meaning if test disabled 4 5 DIP SWITCH DESCRIPTION Table 2 Function Description of SET SW5 Bit ON Detinition OFF Detinition Default 1 Remote loop back No loop back OFF Diagnostic loop back No loop back OFF Local loop back No loop back OFF Use local time slot Follow remote time slot 4 OFF settings settings 19 Er ibridge E1 amp V 35 Fiber Modem User Manual V1 0 5 Bit error test Normal operation OFF 6 V 35 clock NORMAL V 35 clock RESERVED OFF 7 OFF Timing mode selection Referring to table 3 8 OFF Note 1 SET is for standalone and SW5 is for module 2 Follow remote timeslot setting means one side of F4 56 s timeslot will follow to the other side of F4 56 s all the time Only in framed mode amp Bit7 Bit8 being set as ON OFF it is available For example you use one
10. tion 5 1 Peer to Peer E1 modem used in pairs El Fiber El DDN ATM E1 Modem E1 Modem DDN ATM V 35 modem used in pairs V 35 Fiber V 35 Router V 35 Modem V 35 Modem Router E1 modem amp V 35 modem used together In the above application it is recommended that user select router s timing signal as unique timing source and makes all the other equipment follow this timing source 18 Gr ibridge E1 amp V 35 Fiber Modem User Manual V1 0 5 2 Star Topology E1 or V 35 Cable i Fiber m Router E1 or V 35 n Fiber Moden 16 slot Converter l j Chassis i E1 or V 35 Cable Router l E1 or V 35 l i Fiber Modem User End 6 Diagnosis and Maintenance 6 1 Local Loop Back Setting a Set bit 3 of SET SW5 ON then the E1 or V 35 fiber modem is forced to under local loop back test mode b Or connect the TX and RX of optical port with a fiber cable E1 V 35 Tester 14 Er ibridge E1 amp V 35 Fiber Modem User Manual V1 0 C d Connect E1 or V 35 port on fiber modem to a Router or a Transmission Analyzer as picture above If local loop back successful all red LEDs on the converter should be off and TXD amp RXD LEDs should blink 6 2 Diagnostic Loop Back Setting r E1 V 33 i E1 V 35 M E1 V 35 Tester As the picture above set E1 or V 35 fiber modem working in framed mode Set bit 2 of SET SW5 on remote end ON to perform di
11. www fibridge tr com bilgi gym tech net GYM Bilgi Teknolojileri E1 and V 35 Fiber Modem User Manual Version 1 0 Z Fibridge Beijing Fibridge Co Ltd 3 1 3 2 3 3 3 4 3 5 3 6 4 1 4 2 4 3 4 4 4 5 5 1 5 2 6 1 6 2 6 3 7 1 7 2 Table of Content 10 177 1 VIC WW c 1 keatures za en 1 Specification eese 2 Efunterface uide dean 2 Optical interface ee 3 V 35 Interface un 3 SIZE 4 POWSGF ues A se n 4 Environment sssssseeseeeeeneenen enne 5 Appearance cuce c rere nt nennen ean noinine necne 6 Front panel of standalone sessssse 6 Back panel of standalone ssss 6 Front panel of chassis seseeeees 7 LED Description ceret eee 8 DIP SWITCH DESCRIPTION eeeeeeee 9 Typical Application eese 13 Peer t PEE iui ec rer eite 13 Star Topology 2 2 25 2 Mack e etes 14 Diagnosis and Maintenance 14 Local Loop Back Setting ssssss 14 Diagnostic Loop Back Setting 15 Remote Loop Back Setting 16 Order Information eere 17 Model 2 nee renden 17 F ibridge E1 amp V 35 Fiber

Download Pdf Manuals

image

Related Search

Related Contents

この製品のカタログPDFへ  Panasonic DMRE500HEBS DVD Player / HDD Recorder  Spice QT-95 User‟s Manual  SYBA CL-CRD20061 card reader  取扱説明書01-08  Processor Expert - University of New Hampshire  OM, Klippo, Lawnmaster, Lawnmaster Golf, 2010-02  coen-2004-project-19.. - Computer Engineering  battery operated patient lift model : mds400el  品番 DMW-MCTZ7  