1. 8435 PowerPad E QUICK START USER GUIDE IMPORTANT WARRANTY NOTE By registering online within 30 days from the date of purchase your warranty will be extended to 3 years AEMC INSTRUMENTS PRODUCT PACKAGING Shipping Contents 1 Large Classic Tool Bag Cat 2133 73 1 PowerPad Model 8435 Cat 2136 41 or Cat 2136 42 oso 5 Black Test Leads and Alligator Clips Cat 2140 73 Stat e 1 110V Power Cord a st SA Cat 5000 63 12 Color coded ID Markers Cat 2140 45 Also Included e 4GB USB Stick DataView User Manual e 9 6V NiMh Battery installed e 2 GB SD Card installed e High Voltage Warning Caution Card 1 5 ft USB Cable Cat 2140 46 Kit Cat 2136 42 only also includes e 4 AmpFlex Model A196 24 BK USB STICK DataView software and complete user manual for the Model 8435 can be located on the USB stick supplied with the instrument X COONS 2 Statement of Compliance Chauvin Arnoux Inc d b a AEMC Instruments certifies that this instrument has been calibrated using standards and instruments traceable to international standards We guarantee that at the time of shipping your instrument has met its published specifications An NIST traceable certificate may be requested at the time of purchase or obtained by returning the instrument to our repair and calibration facility for a nominal charge The recommended calibration inter
2. Configure the PowerPad SET UP Take a snapshot of the current screen or access screens already stored in the memory Record associated waveform and power measurement data Get help on the current display functions in the language chosen by the user Transients or Inrush Current e Sets and views transient and inrush current waveforms associated with rapid changes in input Harmonics Mode e Displays the harmonics in percent and value ratios for voltage current and power for each harmonic through the 50th e Determines harmonic current produced by non linear loads e Analyzes the problems caused by harmonics according to their order heating of neutrals conductors motors etc Waveforms Mode e Displays voltage and current waveforms or vector representation e Identifies signal distortion signatures e Displays of amplitude and phase unbalance for voltage and current e Checks connections for correct phase order Alarm Events e Provides a list of the alarms recorded according to the thresholds programmed during configuration e Logs interruption with half cycle resolution e Determines energy consumption exceedances e Stores value duration date time and set point for up to 4096 events Trend Mode e Lists all recording trends and views them on the display Urms Vrms Arms etc Power Energy e Displays power levels and the associated parameters power factor displacement and tangent e Energy monitoring e Four qu
3. Instruments will do If a malfunction occurs within the warranty period you may return the instrument to us for repair provided we have your warranty registration on file or a proof of purchase AEMC Instruments will at its option repair or replace the faulty material Warranty Repairs What you must do to return an Instrument for Warranty Repair First request a Customer Service Authorization Number CSA by phone or e mail from our Service Department then return the instrument along with the signed CSA Form Please write the CSA on the outside of the shipping container Return the instrument shipment pre paid to Ship To Chauvin Arnoux Inc d b a AEMC Instruments 15 Faraday Drive e Dover NH 03820 USA Phone 800 945 2362 or 603 749 6434 Ext 360 E mail repair aemc com Caution To protect yourself against in transit loss we recommend you insure your returned material NOTE You must obtain a CSA before returning any instrument EJ AEMC INSTRUMENTS 11 14 99 MAN 100390 v2 Chauvin Arnoux Inc d b a AEMC Instruments 15 Faraday Drive e Dover NH 03820 USA e Phone 603 749 6434 Fax 603 742 2346 www aemc com
4. 1 100A sensitivity 10mV Aac oc 10A sensitivity 100mV Aacyoc e 5A three phase adapter 3 channel only Transient Mode Configures the voltage and current thresholds Trend Recording Mode Selects the parameters to record up to 4 configurations D Alarm Mode efines the parameters of an alarm Erase Memory Deletes configurations alarm settings snapshots and recordings About O sd Displays the serial number software and hardware version SD Card SD Cards up to 2GB only are supported To access the SD Card e Make sure that the instrument is disconnected and off e Use a screwdriver to unscrew the 6 screws of the battery compartment cover e Remove the cover and withdraw the battery from its compartment without disconnecting it e Press on the SD Card to release it then press on the protecting tab to withdraw it from its slot e When replacing the SD Card the contacts must be on the left side and the locator down e Slide it into its slot until it snaps into place The protecting tab is at the top of the card e Put the battery back in its compartment and screw the cover back on Getting Started NOTE Make sure the PowerPad is fully charged before use mio Connecting e Start the instrument by pressing the D button e Configure the instrument to obtain the required results and type of network e Connect the current leads and sensors to the PowerPad e Connect the ground and or neutral lead to th
5. adrant measurement to discern source load active energy and inductive capacitive reactive energy Control Features m o N C1 oH i 9 Al O _ A OO aoaan o oxos Protective cover Battery charging connector Six function buttons yellow Four function buttons see chart left ON OFF button Four current inputs and five voltage inputs OF Ol ON ss Connection Terminals ee LCD Display USB port Confirm Enter button 10 11 12 Navigation buttons Six mode buttons see chart left Battery compartment and SD Card slot cover 1 Four 4 current inputs on the top of the instrument to enable the use of current sensors MN SR AmpFlex MiniFlex J93 and MR probes 2 Five 5 voltage inputs Each terminal is protected by a weatherproof plug The plugs must be removed to connect the leads then stored in the pouch inside the front cover Leave the plugs on unused terminals to keep the instrument water air tight and the terminals clean Instrument Configuration NOTE The instrument configurations can also be modified through the DataView software NOTE The instrument must be configured the first time it is used The configura
6. asurement Categories CAT CATIV Measurement category IV corresponds to measurements taken at the source of low voltage installations Example power feeders counters and protection devices CAT Ill Measurement category III corresponds to measurements on building installations Example distribution panel circuit breakers machines or fixed industrial devices CAT Il Measurement category II corresponds to measurements taken on circuits directly connected to low voltage installations Example power supply to domestic electrical appliances and portable tools A Precautions for Use A This instrument and its accessories comply with safety standards IEC 61010 1 IEC 61010 031 and IEC 61010 2 032 for voltages of 600V in category IV or 1000V in category III Failure to observe the safety instructions may result in electric shock fire explosion and destruction of the instrument and of the installations The operator and or the responsible authority must carefully read and clearly understand the various precautions to be taken in use Sound knowledge and a keen awareness of electrical hazards are essential when using this instrument If you use this instrument other than as specified the protection it provides may be compromised thereby endangering you Do not use the instrument on networks of which the voltage or category exceeds those mentioned Do not use the instrument if it seems to be damaged incomplete or poorly closed Be
7. e network ground and or neutral when distributed as well as the corresponding current sensor e Connect the L1 phase lead to the network L1 phase as well as the corresponding current sensor e Repeat the procedure for phases L2 L3 and N Disconnecting e Proceed in the reverse order to connecting always finishing by disconnecting the ground and or neutral when distributed e Disconnect the leads and press the D button to turn the instrument off e Recharge the battery if necessary Installation of the Leads and Current Sensors Color coded ID markers are supplied with the PowerPad to identify the leads and input terminals e Detach the appropriate inserts from the color coded marker and place them in the holes provided under the terminals larger inserts for current terminals smaller inserts for voltage terminals e Clip the ses of the same color to the ends of the lead that will connect to the terminal Installing DataView Q DO NOT CONNECT THE INSTRUMENT TO THE PC BEFORE INSTALLING THE SOFTWARE AND DRIVERS 1 Insert the USB stick into an available USB port wait for driver to be installed 2 If Autorun is enabled an AutoPlay window should appear If Autorun is disabled it will be necessary to open Windows Explorer then locate and open the USB stick drive labeled DataView to view the files on the drive 3 In the AutoPlay window select Open folder to view files 4 Do
8. fore each use check the condition of the insulation on the leads housing and accessories Any item of which the insulation is deteriorated even partially must be set aside for repair or scrapping Use only the leads and accessories supplied Using leads or accessories of a lower voltage or category reduces the voltage or category of the combined instrument leads or accessories to that of the leads or accessories Use personal protection equipment systematically Keep your hands away from the terminals of the device When handling the leads test probes and alligator clips keep your fingers behind the physical guard Use only the AC power adapter and battery pack supplied by the manufacturer They include specific safety features Some current sensors must not be placed on or removed from bare conductors at hazardous voltages refer to the sensor manual and comply with the handling instructions Charging the Battery Fully charge the battery before the first use i NOTE A full recharge of a completely discharged battery takes approximately 5 hrs 120V 10 60Hz To recharge the battery 230V 10 50Hz gC B e Unscrew the cover of the battery charging connector e Connect the supplied power cord to the instrument and AC power The button lights and will go out when the power cord is disconnected DESCRIPTION Return to the choice of measurement view
9. tion is saved in memory when the instrument is turned OFF Press the 29 button to configure the unit The following sub menus appear Date Time Cakulaton methods Etoctric at connection Sensors and ratios Transiera moge Trend mode Alam mode Erase momary About e Press the yellow button corresponding to the language to set the display language e The parameter that is ready to be configured will be highlighted in yellow To move to a different parameter use the A and Y buttons e Press the Enter button to select a parameter e Use the lt and gt buttons to change a value or setting e When finished return to the Configuration menu by pressing the lt gt button PARAMETER FUNCTION Defines the color of the voltage and current curves Calculation Methods Determines if harmonics are used or not used in calculations of reactive quantities power and energy e With harmonics Harmonics are taken into account when calculating reactive parameters e Without harmonics Only the fundamental part is used for the calculation of reactive parameters Electrical Connection Determines the type of connection to the network e Single Phase e Split Phase e 3 Phase 4 Wire e 3 Phase 5 Wire Sensors amp Ratios Defines the type of current probe to connect MN93 200Aac MN193 100A or 5Aac with variable ratio SR193 1000Aac J93 3500Aac 5000ADc AmpFlex Sensors 6500Aac MiniFlex Sensors 6500Aac MR193 1000A 1200Aac 0c SL26
10. tside of the shipping container If the instrument is returned for calibration we need to know if you want a standard calibration or a calibration traceable to N I S T Includes calibration certificate plus recorded calibration data Ship To Chauvin Arnoux Inc d b a AEMC Instruments 15 Faraday Drive e Dover NH 03820 USA Phone 800 945 2362 or 603 749 6434 Ext 360 Fax 603 742 2346 or 603 749 6309 E mail repair aemc com NOTE You must obtain a CSA before returning any instrument Technical and Sales Assistance If you are experiencing any technical problems or require any assistance with the proper operation or application of your instrument please call fax or e mail our technical support team Chauvin Arnoux Inc d b a AEMC Instruments Phone 800 343 1391 or 508 698 2115 Ext 351 Fax 508 698 2118 E mail techsupport aemc com Limited Warranty The Model 8435 is warranted to the owner for a period of one year from the date of original purchase against defects in manufacture This limited warranty is given by AEMC Instruments not by the distributor from whom it was purchased This warranty is void if the unit has been tampered with abused or if the defect is related to service not performed by AEMC Instruments Full warranty coverage and registration is available on our website www aemc com warranty html Please print the online Warranty Coverage Information for your records What AEMC
11. uble click on Setup exe from the opened folder view to launch the Dataview setup program NOTE For more information on using DataView refer to the Model 8435 user manual that is supplied on the USB stick Updating Software amp Firmware To provide our customers the best possible service in terms of performance and technical upgrades AEMC offers free software and firmware updates on our website e Visit us at www aemc com e Click on the TECH INFO tab then click on the Software amp Firmware Updates button DataView can also be updated by selecting Update from the Help menu within the software WARNING Updating the firmware will erase all stored data in the instrument It is recommended to download all stored data before performing any firmware updates g I IMPORTANT WARRANTY NOTE By registering online within 30 days from the date of purchase your warranty will be extended to 3 years Repair and Calibration To ensure that your instrument meets factory specifications we recommend that it be scheduled back to our factory Service Center at one year intervals for recalibration or as required by other standards or internal procedures For instrument repair and calibration You must contact our Service Center for a Customer Service Authorization Number CSA This will ensure that when your instrument arrives it will be tracked and processed promptly Please write the CSA on the ou
12. val for this instrument is 12 months and begins on the date of receipt by the customer For recalibration please use our Calibration services Refer to our repair and calibration section at www aemc com Serial Catalog 2136 41 2136 42 Model 8435 Please fill in the appropriate date as indicated Date Received Date Calibration Due Chauvin Arnoux Inc d b a AEMC Instruments INSTRUMENTS www aemc com Thank you for purchasing an AEMC PowerPad Ill Model 8435 For best results from your instrument and for your safety read the enclosed operating instruc tions carefully and comply with the precautions for use These products must be only used by qualified and trained users WARNING risk of DANGER The operator must refer to these instructions whenever this danger symbol appears CAUTION Risk of electric shock The voltage at the parts marked with this symbol may be dangerous Equipment is protected by double insulation USB socket SD Card Ground Earth Important instructions to read and to fully understand Useful information or hint to read The CE marking guarantees conformity with European directives and with regulations covering EMC The trash can with a line through it means that in the European Union the product must undergo selective disposal for the recycling of electric and electronic material in compliance with Directive WEEE 2002 96 EC Definition of Me