Home

HYDROGEN PEROXIDE GAS STERILIZER

image

Contents

1. O HYDROGEN ee GAS STERILIZER 5 00 Canon Lifecare Solutions Inc There has never been a high speed low temperature sterilization system that was easier to deploy ES 70 is the new benchmark SVYOROGEY PARARGHDE GAS STERLE EF pa See what Canon Lifecare Solutions Inc s b hydrogen peroxide gas sterilizer is capable of Thanks to reliable and trusted technologies we have developed over the years we have been able to take all the prerequisite conditions of sterilizers performance operability and safety to a much higher level We were also abl amp to make unprecedented advances in cost performance ES 700 brings high speed low temperature sterilization much n to our customers ThiSeis the dawn of a new era of sterilization OJ Royal Blue What is hydrogen peroxide gas sterilization This is a new system whereby sterilization is achieved by injecting gasified hydrogen peroxide into an evacuated sterilization chamber no higher than 50Pa This method enables the sterilization of inner cavities and does not require special facilities such as plasma generators Hydrogen peroxide chemically decomposes into water and oxygen which means the unit needs no ducts and is environmentally friendly With the ability to safely and consistently achieve sterilization in a short amount of time 60 minutes this is a sterilization process for a new era Pe rfo r m N C e Excellent Sterilization Perfor
2. to make the most efficient use of space with enough capacity to take a j full sized container 76 liters It also comes standard with E 3 racks that are easy to access allowing users to make 85cm l the most effective use of space when sterilizing a large kal number of items All racks slide out for easy access to items placed towards the back Racks can also be removed to accommodate items of various heights lts capacity rivals that of 100L and larger cylindrical chambers Single Rack Configuration Triple Rack Configuration Easily accommodates a full sized container Sliding racks are heightadjustable All racks slide out to allow easy access to items placed towards the back It can also be used in a tworack configuration Automatic Door with Footswitch The door swings down automatically by either operating the touch panel or footswitch Additionally not only are there fewer protrusions on the front the door open close movement is confined within a symmetrical space which makes it a great choice for the often limited spaces ES 700 comes with a footswitch so user s can open and close the door without The door automatically swings down touching the panel This is not only hygienic but also convenient when both hands are occupied Full English Chinese Japanese LCD Display Touch panel operations are available at a touch of your finger The LCD display uses large text for good v
3. aintenance Door Automatic swing down door Approval number 22300BZX00074A01 Hydrogen peroxide supply Cartridge Generic name HYDROGEN PEROXIDE GAS STERILIZER ES 700 Sterilization temperature 50 C Sales name High Speed Low Temperature Sterilization System ES 700 Process time cycle Approx 60 minutes Made in Japan Japan Pharmaceutical Affairs Act Please note that the product shown is subject to modifications or changes to its specifications without notice Please also note that product colors shown may vary slightly from actual product colors due to irregularities in the printing process Do not place flammable items such as alcohol gasoline and gas in the sterilizer as these may explode Always connect the unit to a dedicated 3 phase power supply with at least 200VAC at 20A Make sure that its ground is connected to a line that has been installed according to type D type 3 ground line specifications Read the User s Manual well before using unit and use the unit properly Safety The sterilizer is categorized as a small pressure vessel for the purpose of the Industrial Safety and Health Law Therefore make sure to carry out R d self initiated inspections on a regular basis eminaers Make sure to manage sterilization outcomes Use the chemical indicator on a daily basis and the biological indicator on a periodic basis Contact the following for orders and inquiries Canon Lifecare Solutions Inc Overseas Divisio
4. g conditioning ae Li D a i a 41 ST A tt a E Wa a e f Ro a L1_ m ni e oA LED lighting makes it easy to check the interior Comes with an e mail function The unit will notify you by e mail when sterilization is complete or if an error occurs ES 700 registers up to 5 e mail addresses and the information to be sent to each recipient can be configured individually Requires a LAN connection Safety Improved safety ALV Alternating Ventilation system Since the hydrogen peroxide gas that is supplied to the chamber has been gasified to the molecular level much smaller than particles using ELK s proprietary gasification technology there is no concern for residual liquids In addition in the final process during sterilization the unit performs Alternating Ventilation AV where depressurization and pressurization are repeated This process reduces the amount of residual hydrogen peroxide in wrapping material and containers Long mode Ventilation depressurization and introduction of atmosphere is performed 5 times in the ventilation process to ensure Sterilization thorough ventilation Users can add 5 more ventilation cycles A to ensure an even safer working environment DE Alternates between depressurizing and pressurizing to reduce residual levels Passe set pre sterdizaton carnage The steriliza
5. isibility A red screen and sound alerts the user should any error occur Start sterilization LED lighting and view port makes it easy to check the interior The interior of the sterilization chamber is lit with white LED lamps which allows users to check at a glance how the items are laid out and to check for any items that may have been left behind ES 700 also features a view port for checking the sterilization status while the door is shut Look into the view port to check the interior during sterilization The screen turns red to alert the user to any errors Eco mode switch This switch is used to reduce standby power consumption When you press this switch the screen and chamber lights turn off to reduce power consumption ES 700 also comes with an auto function that allows you to set eco mode at your discretion and hence improve the efficiency of your sterilization operations by reducing waste Users can also set the standby temperature inside the chamber to their desired value Displays Remaining Processing Time During the sterilization process the display shows the remaining time in large format which helps to improve work efficiency Sterilization may take longer depending on the type of material or dryness of items to be sterilized The remaining process time on the display is based on the process end time which is calculated based on the conditions of the initial depressurizin
6. mance Canon Lifecare Solutions Inc s proprietary gasification technology delivers excellent sterilization performance We have succeeded in achieving molecular level gasification using our proprietary gasification technology In addition ES 700 employs a high performance dry vacuum pump to achieve a high level of vacuum The unit s thorough sterilization is achieved through a 4 pulse process in which hydrogen peroxide gas is injected 4 times This allows the unit to thoroughly sterilize inner cavity structures complex shapes and wrapping material that have traditionally been difficult to sterilize Standard and Soft Modes The unit is designed to run on either standard or soft mode Users can choose the most effective sterilization process to take into account the effects if any that hydrogen peroxide may have on their equipment and depending on the shape of items to be sterilized Make sure to choose the appropriate mode based on instructions provided by the manufacturer of the item to be sterilized Use standard mode unless specified otherwise Initial Depressurization Sterilization Ventilation Proprietary Proprietary gasification technology and 4 pulse process high performance Hydrogen peroxide gas is gasified to the molecular level dry vacuum pump and injected 4 times O o era ti ON Excellent Operability Rectangular chamber is space efficient and easy to use fm A rectangular chamber was employed
7. n 2 17 4 5F Yushima Bunkyo ku Tokyo 113 0034 Japan TEL 81 3 3818 1324 FAX 81 3818 1814 Manufactured by Elquest Corporation dn go 741 Owa Tomisato shi Chiba i Sun 0 D
8. tion cartridge is made of a dual wall construction that holds up well against impact The user will be automatically notified of its usage count and expiration Wear gloves when handling the cartridge I cdi Rec O rd a Q Record keeping Includes a process printer and SD card as standard The printer automatically prints out a process record for each cycle This data is also stored on an SD card Data on the SD card can be easily viewed on your spreadsheet program It offers users a way to make long term backups for greater peace of mind Printout History Table example Premium Black Accessory Sterilization Cartridges e 7 SC3 3 times usage e E SC 5 5 times usage e 7 SC 0 10 times usage The cartridge s container consists of a Three unit color choices are available Royal Blue Sicilian Orange and Premium sturdy dual wall construction It is also Black Choose a color that most suits the color theme of your clinic or hospital designed with accidental leaks in mind Bi H Three choices of color Primary specifications Outer dimensions mm 1630 H x750 D x640 W Thermal printer included as standard Capacity 76L SD card for data storage included as standard Weight 310kg Other Status display LCD Power supply 3 phase 208VAC 380VAC 400VAC 415VAC at 50 60Hz Medical device Controlled medical device Class power consumption 2KW category Controlled medical devices requiring special m