Home

Internet Telephony Gateway VGW-402 / VGW-400FS / VGW

image

Contents

1. Default WAN IP 172 16 0 1 Default subnet mask 255 255 255 0 Default Gateway 172 16 0 254 Default PC IP 192 168 0 1 Default Login User Name admin Default Login Password admin Windows Security The server 192 168 142 at VoIP Device Management requires a username and password Waming This server is requesting that your username and password be sent in an insecure manner basic authentication without a secure connection User name ww Password E Remember my credentials Login page of the VGW 400 Series For security reason please change and memorize the new pass word after this first setup 3 2 Configuring the Network Setting Step 1 Go to Device Setting Network gt PLANET 4 Port SIP VoIP Gateway Hetworking amp Communication ii Advance User Login Debug Event Notice Provisioning IP Support IPV40nly Y WAN Setting VOIP Advance Network Type Fixed IP Device Setting NAT Setting VOIP Setting Dialing Plan IP Address 172 16 0 1 FXS Setting Netmask 255 255 0 0 FXO Setting Default Gateway 172 16 0 254 SIP Trunk DNS Serverl 168 192 1 12 Route Plan DNS Server2 168 192 112 Status VOIP VLAN OEnable Disable Network setting page Step 2 Edit your WAN port IP information There are three types of IP Support They are IPV4 only IPV4 IPV6 and IPV6 only There are also three types of WAN port connection They are Static
2. The following are the safety instructions for Internet Telephony Gateway system before installing The maximum operating temperature of the VGW 400 Series is 0 45 C Care must be taken to allow sufficient air circulation The connections and equipment that supply power to the VGW 400 Series should be capable of operating safely with the maximum power requirements of the VGW 400 Series In the event of a power overload the supply circuits and supply wiring should be become hazardous The power adapter must plug into the right supply voltage Make sure that the supplied power voltage is correct and stable If the input power voltage is over 10 lower than the standard it may cause the VGW 400 Series to malfunction Generally when installed after the final configuration the product must comply with the applicable safety standards and regulatory requirements of the country in which it is installed If necessary consult your technical support 2 2 Physical Introduction Internet Telephony Gateway TX VGW 400 Series 2 WAN LAN Proxy Status Power oco Rear Panel of the VGW 402 EL Reset 3 p iL CI Cd 4 3 2 1 LAN Rear Panel of the VGW 400FS FXO DC 12V eMn 00 WAN LAN Rear Panel of the VGW 400FO 2 3 LED amp Button definitions LED definitions LED Function Description Power When the power adapter is connected the LED will light up green Status When system starts up
3. IP PPPoE Point to Point Protocol over Ethernet and DHCP You can find detailed setting process in the user manual gt PLANET 4 Port SIP VoIP Gateway Motworking amp Communication Advance User Login Debug Event Notice Provisioning IP Support IPV4 Only v WAN Setting IPV4 Only IPVAIIPVE IPV6 Only Device Setting NAT Setting VOIP Setting VOIP Advance Network Type 9 H _ PLANET 4 Port SIP VoIP Gateway Networking amp Communication s Advance User Login Debug Event Notice Provisioning Device Setting NAT Setting SSS SS ji IP Support IPV4 Only VOIP Setting WAN Setting VOIP Advance Network Type Fixed IP v Fixed IP Dialing Plan IP Address DHCP PPPoE FXS Setting Netmask 255 255 0 0 FXO Setting Default Gateway 172 16 0 254 SIP Trunk DNS Serverl 168 192 1 12 Selection of IP Support Network Connection Type 3 3 Changing IP Address or forgotten admin password To reset the IP address to the default IP address 192 168 0 1 LAN or reset the login password to default value press the reset button on the front panel for more than 5 seconds After the device is rebooted you can login the management Web interface within the same subnet of 192 168 0 xx Reset Button After pressing the Reset button all the system data will be reset to default if possible back up the config file before resetting 4 Further Conf
4. successfully the LED will light up green Proxy When the gateway is registered successfully to a SIP Proxy this will light up green WAN This LED lights up green when the gateway s WAN port is physically connected to the public internet When data is transmitted through this port it will flash green This LED lights up green when the gateway s LAN port is physically connected to a local network Refer to Rear Panel section When data is transmitted through this port it will flash green Port 1 4 The status LEDs for FXO and FXS ports will light up amber orange when connected phone is engaged in a conversation mode FXO It will flash amber orange when there is an incoming call FXS Button definitions Port Function Description Reset Press and hold over 5 seconds to reload factory default setting This action will erase all existing settings configured on this gateway FXS Ports The status LED for FXS port will light up amber orange when the connected phone s handset is lifted or when the connected phone is engaged in a conversation It will flash amber orange when there is an incoming call FXO Ports The status LED for FXO port will blink to remind you that there is no PSTN line connected When PSTN line is connected but not in talking mode the LED is OFF When a line is using the LED lights up steadily 10 100 Base T RJ 45 socket for LAN port connects to PC for mana
5. Internet Telephony Gateway VGW 402 VGW 400FS VGW 400FO Quick Installation Guide Table of Contents 1s Package Contents 3 2 Hardware installato 4 2 1 Safety ASTUN S mita is 4 2 2 Physical Intro dU CHO naaa a 5 2 3 LED 8 Button definitions omic es fica 6 2 4 Placement s asa ai 7 2 31 Physical Connections illa dolo dalai 7 3 Basie System Configuration a sale 8 Sk WebLogic ta ian 8 3 2 Configuring the Network Setting cece ee eee eee eeee sense eee eee ai 9 3 3 Changing IP Address or forgotten admin password eee es 10 A Further CONMGUMALION sive sis vind aed fe a a eddies delle oa 11 1 Package Contents Thank you for purchasing PLANET Internet Telephony Gateway VGW 400 Series This Quick Installation Guide will introduce how to finish the basic setting of connecting the web management interface and the Internet Open the box of the Internet Telephony Gateway and carefully unpack it The box should contain the following items e VGW 400 Series x 1 e Quick Installation Guide x 1 e User s Manual CD x 1 e Power Adapter x 1 12V e RJ 45 x 1 If any of the above items are damaged or missing please contact your dealer immediately 2 Hardware Installation The following are instructions for setting up PLANET VGW 400 Series Refer to the illustration and follow the simple steps below to quickly install your Internet Telephony Gateway 2 1 Safety Instructions
6. gement purpose WAN 10 100 Base T RJ 45 socket for WAN port connects to wide area network 12V DC The power socket input AC 100V 240V output 12V DC 2A 2 4 Placement e Make sure the device is placed in a safe environment to avoid equipment failure e DO NOT place anything on top of the device Excessive weight could damage it e DO NOT obstruct ventilation slots on each side of the VGW 400 Series or expose it to direct sunlight or other heat source Be sure that there is adequate air flow around the VGW 400 Series e Place the VGW 400 Series on a flat surface to avoid any damage 2 5 Physical Connection Router Switch TR SLT Phone Fax x Internet 5p Telephone wire y pcia IP PBX ATA Video Phone IP Phone PC Physical Connection Topology of the VGW 400 Series 71 3 Basic System Configuration 3 1 Web Login Step 1 Connect a computer to a LAN port on the VGW 400 Series Your PC must be set to 192 168 0 X the same domain as that of the VGW 400 Series Step 2 Start a web browser To use the user interface you need a PC with Internet Explorer version 6 and higher Firefox or Safari for Mac Step 3 Enter the default IP address of the VGW 400 Series 192 168 0 1 into the URL address box Step 4 Enter the default user name admin and the default password admin and then click Login to enter Web based user interface Default IP
7. iguration Thank you for purchasing PLANET products The above steps introduce the simple configuration of the VGW 400 Series For further configuration please refer to the user s manual on the CD If you have other questions please contact the local dealer or distributor where you purchased this product You also can browse our online FAQ resource on the PLANET Web site first to check if it could solve your issue If you need more support information please contact PLANET support team PLANET online FAQ http www planet com tw en support fag php Support team mail address support planet com tw Copyright PLANET Technology Corp 2013 Contents are subject to revision without prior notice PLANET is a registered trademark of PLANET Technology Corp All other trademarks belong to their respective owners This page is intentionally left blank

Download Pdf Manuals

image

Related Search

Related Contents

Vision TC2-HDMIIPRX    Human Humax 4K - Frank`s Hospital Workshop  Specs  HB 60 - FSH Welding Group  SIEMENS PLC et200s_4ai_i_2wire_st_manual_es 2013  弊社同制度の資料  Bedienungsanleitung  Introduction  Therma-Stor Products Group PHOENIX D385 User's Manual  

Copyright © All rights reserved.
Failed to retrieve file