Home
Therma-Stor Products Group PHOENIX D385 User's Manual
Contents
1. ccceceeccssseeceeaeseeneaees 3 2 A EO COMON a O EGN 4 2 5 Electrical Requirements ccceeeeeeeeeeeeeeeeeaees 4 26 COMUOl Pane aeeccs tncswce E ameuaeeoass 4 ZOA POW SWECO i aaa 4 ZIOB PilO ICM araa ATR 4 ZOC HOUN METO viwedecileiinte drtiadinnactuenaenieanneieees 4 2 f Ducting CONNECTIONS ccccceceeceeeeeeeeeseeeeees 4 2 8 Storage and Transportation ccceeceeeeeeeeees 5 3 Maintenance nnnnannnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnne 5 3 1 Air Filter REeplaceMent ccccueccessesceecseeseecess 5 A SOV ICC avast occa A 5 iA NVA AIRY satis Vencaaies a 5 5 Wiring DIASIAINN c cccccionisciopissrnanircoie nirearen 5 6 SEFVICe Parts LISE sicseiisiiletintadedsadininccomeaeeenedaiens 6 Te Waranty seit oa ese as oe ate ieee aia eee T Serial No Purchase Date Dealers Name Read the operation and maintenance instructions carefully before using this unit Proper adherence to these instructions is essential to obtain maximum benefit from your Phoenix D385 dehumidifier Toll Free 1 800 533 7533 1 Specifications Part No Power Water Removal Blower Operating Range Filters Duct Connections Warranty Dimensions Width Height Depth Weight 4026700 2 circuits 11 Amps 115 VAC each 22 Amps total power consumption 116 pints per day AHAM 385 CFM Process Airflow 75 CFM Reactivation Airflow Up to 140 F As low as 10 F Process filter s
2. 85 desiccant dehumidifier will continue to remove water from already dry cold air It is possible to over dry objects and or structures NCAUTION Care must be taken to avoid secondary damages due to over drying 2 3 Universal Use Set Up When conditions warrant the use of a desiccant dehumidifier use the set up shown below Fig 3 This universal set up will produce efficient drying while avoiding secondary damages The Phoenix D385 has been designed with the goal of being easy to use every time Figure 3 Universal D385 Set up _ www usephoenix com sales thermastor com 2 4 Location Note the following precautions when locating the Phoenix D385 AWARNING It is designed to be used INDOORS ONLY If used on a water loss work site plug it into GROUND FAULT CIRCUIT INTERRUPT GFCI OUTLETS The air inlet on top and the side outlet must be at least 1 foot from walls and other air flow obstructions If the humid area is very large dehumidification can be improved by adding an outlet duct to circulate process air to stagnant areas DO NOT use the Phoenix D385 as a bench or table 2 5 Electrical Requirements When used on a water loss work site ground fault circuit interrupter GFCI outlets are required Your Phoenix D385 requires a total of 22 amps 115VAC In order to run at all this machine must be plugged into two separate circuits each with a minimum of 11 amps dedicated capacity ava
3. EL BELT DRIVE PHOENIX DESICCANT WHEEL DESICCANT THERMAL OVERLOAD CUT OUT SWITCH REACTIVATION AIR FILTER AIR 16 X 20 X 2 PROCESS AIR SWITCH ROCKER DPST ON OFF PLATE SKID WHEEL PU 12 00 GRAY 2 PLACES COLLAR DUCT WIRE 5 75 X 12 00 Description CORD 14 3 SJT 115V W PLUG 25 2 PLACES GASKET AND BELT REPLACEMENT KIT Specifications subject to change without notice www usephoenix com sales thermastor com x Phoenix D385 Dehumidifier Limited Warranty NEY NZ Warrantor Wy Ra Therma Stor LLC Vn PO Box 8680 IRIN Madison WI 53708 X88 Telephone 1 800 533 7533 ROM Who Is Covered This warranty extends only to the original end user of the Phoenix D385 dehumidifier and may not be assigned or transferred One Year Warranty Therma Stor LLC warrants that for one 1 year the Phoenix D385 dehumidifier Wiens will operate free from any defects in materials and workmanship or Therma Stor LLC will at its N option repair or replace the defective part s free of any charge RO End User Responsibilities Warranty service must be performed by a Servicer authorized by Therma BQO Stor LLC If the end user is unable to locate or obtain warranty service from an authorized Servicer VERY the end user should call Therma Stor LLC at the above number and ask for the Therma Stor Service Yy Department which will then arrange for covered warranty service Warranty service will be performed M during normal workin
4. NDER ANY LEGAL THEORY FOR Oi ANY SPECIAL INDIRECT OR CONSEQUENTIAL DAMAGES INCLUDING WITHOUT LIMITATION WATER EXC DAMAGE THE END USER SHOULD TAKE PRECAUTIONS AGAINST SAME LOST PROFITS DELAY OR LOSS OF USE OR DAMAGE TO ANY REAL OR PERSONAL PROPERTY I e Some states do not allow limitations on how long an implied warranty lasts and some do not allow Wes the exclusion or limitation of incidental or consequential damages so one or both of these limitation ex may not apply to you KC SEN Legal Rights This warranty gives you specific legal rights and you may also have other rights which BOY vary from state to state Toll Free 1 800 533 7533 www usephoenix com sales thermastor com
5. a glance from across the room the operator can verify that the D385 is operating as it should 2 6C Hour Meter The hour meter will run whenever your D385 is on This digital hour meter measures the cumulative time of operation in one tenth hour increments This non resettable time is often used to verify hours on a job or to schedule maintenance When the D385 is un plugged the timer will continue to hold and display the cumulative hours run 2 7 Ducting Connections Using excess duct length significantly reduces air flow volume through duct This is true in any application If the job at hand needs a short length of duct cut a section to the appropriate length If air flow is restricted by excess length performance will suffer The same can be said of excess bends in the ducting Three different duct sizes are used on the D385 All ducting materials are available from Therma Stor LLC see accessories list section 1 Process in 12 flex duct To attach flex duct to the process air intake push the wire of the first couple of loops down below the four tabs in the top cover Process out 10 diameter lay flat plastic duct When inflated this ducting forms a 10 circle 10 lay flat ducting attaches to the D385 by means of a 12 x 6 wire rectangle To attach lay flat ducting to the process exhaust air Fig 1 P3 put the plastic duct end through the collar center and roll the plastic ducting s end outward so tha
6. g hours WAN AZN The end user must present proof of purchase lease upon request by use of the warranty card or NSN other reasonable and reliable means The end user is responsible for normal care This warranty as ON does not cover any defect malfunction etc resulting from misuse abuse lack of normal care RO corrosion freezing tampering modification unauthorized or improper repair or installation accident o acts of nature or any other cause beyond Therma Stor LLC reasonable control OLX SSN Vey Limitations and Exclusions If any Phoenix D385 Dehumidifier part is repaired or replaced the new We part shall be warranted for only the remainder of the original warranty period applicable thereto but AZN all warranty periods will be extended by the period of time if any that the Phoenix D385 Dehumidifier PEN is out of service while awaiting covered warranty service VAXA W LX O KO UPON THE EXPIRATION OF THE WRITTEN WARRANTY APPLICABLE TO THE Phoenix D385 N X M DEHUMIDIFIER OR ANY PART THEREOF ALL OTHER WARRANTIES IMPLIED BY LAW INCLUDING as Vey MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE SHALL ALSO EXPIRE ALL zY WARRANTIES MADE BY THERMA STOR LLC ARE SET FORTH HEREIN AND NO CLAIM MAY BE MADE We AGAINST THERMA STOR LLC BASED ON ANY ORAL WARRANTY IN NO EVENT SHALL THERMA AZN STOR LLC IN CONNECTION WITH THE SALE INSTALLATION USE REPAIR OR REPLACEMENT OF ANY Phoenix D385 DEHUMIDIFIER OR PART THEREOF BE LIABLE U
7. ilable The D385 has two separate power cords each cord must be plugged into its own 15 amp circuit If both cords are plugged into the same 15 amp circuit this circuit will trip when the unit is turned on Another situation to avoid is that one or both of the circuits which the D385 is using can be tripped by other appliances drawing power from either circuit This can happen well after a job site has been set up as in the case with a freezer compressor turning on Care must be taken to insure that the D385 always has sufficient power available to run without tripping breakers or blowing fuses If your location requires the use of an extension cord use safe techniques in selection and connection Such cords must be grounded and rated for carrying 11 amps 14 gauge minimum for one extension less than 25ft in length or 12 gauge for one extension less than 5Oft in length 2 6 Control Panel 2 6A Power Switch The D385 has one control device the power switch When the power switch is moved to the on position your portable desiccant is dehumidifying The machine will continue to dehumidify in all conditions until the power is turned off There is no dehumidistat See over dry warning section 2 2 Toll Free 1 800 533 7533 2 6B Pilot Light The power indicator lamp illuminates to indicate that the D385 is functioning properly This indicator is helpful when a job site is too noisy to know what equipment is running properly At
8. ize 16 x 20 x 2 Reactivation filter size 12 x 12 x 1 Process Inlet 12 Flex Duct optional Process Outlet 10 Lay Flat collar optional Reactivation Inlet 6 Flex Duct optional Reactivation Outlet 6 Flex Duct required One year Parts and Labor Machine Shipping 24 1 4 2 1 2 40 45 1 2 21 3 8 22 105 Lbs 130 Lbs Popular Accessories 4026859 4020128 4024750 4022537 4024935 4024440 6 Metalized Polyester Flex Duct 25 Standard 6 Insulated Flex Duct 25 12 Metalized Polyester Flex Duct 25 10 Lay Flat Duct 500 10 Lay Flat Duct 250 Kestrel 3000 Multi Function Air Meter Process Air Filter Replacement 4021475 16 x 20 x 2 MERV 11 Filter Standard 4024969 16 x 20 x 2 MERV 6 Filter Optional 4022164 16 x 20 x 2 MERV 14 Filter Optional Reactivation Air Filter Replacement 4026315 12 x12 x 1 MERV 7 Filter Standard www usephoenix com sales thermastor com 2 Operation 2 1 How the Phoenix D385 works Your Phoenix D385 has two separate air streams that run through it Process Fig 1 and Reactivation Fig 2 Process Air Stream P1 385 CFM of air enters 12 flex the top of the machine and P2 water vapor from incoming air is deposited on the desiccant wheel P3 385 CFM of dry air exits 10 lay flat the machine Reactivation Air Stream R1 75 CFM of air enters 6 f
9. izontally Process airflow 385 CFM Two 23 power cords 11 Amps per cord 22 Amps 115 Volts 60 Hz Unlimited ducting possibilities Legendary stainless construction Specifications subject to change without notice Toll Free 1 800 533 7533 possibility of tampering with the dehumidifier or the set up The 385 CFM of process air will provide 3 ACH on an affected area up to 7000 cubic feet The Phoenix D385 is easy to transport and set up The D385 will fit on your truck in the areas already designed for your LGR s and will move around the jobsite with the same portability All the power to the unit is provided by two 115 volt grounded power cords Simply plug the cords into separate 15 amp circuits Each cord draws only 11 amps to power the D385 The re activation air stream is ducted through 6 flex duct provided with the unit and stores conveniently in the top of the unit Having completely separate process and regeneration airstreams Where regeneration airstream is pulled from the process airstream Phoenix D385 PN 4026700 TS 387 Revised 7 07 www usephoenix com sales thermastor com Table of Contents Introduction seri ine ee dete ohne eee ere 1 diz SPECHICAUONS eet econ calc teed cecudeureebes trace weeasbe tee lies 2 2 SOPCAUONN oa 3 2 1 How The Phoenix D385 WorkKS snssssannnnnnennnne 3 2 2 Avoiding Secondary DaMages cccceeeneeeees 3 2 3 Universal Use Set Up c
10. lex the lower side of the machine and R2 passes over the heater coils R3 Water vapor is picked up from the desiccant wheel by the hot air and R4 5 CFM of wet air exits 6 flex the machine P3 l Optional 12 Ma Flex Duct lt 385 CFM Optional 10 Lay Flat Duct Figure 1 Desiccant process air stream P1 Required 6 Flex Duct WA RUNA 3 Optional 6 R1 Flex Duct Figure 2 Desiccant reactivation air stream Toll Free 1 800 533 7533 2 2 Avoiding Secondary Damages The D385 is a powerful tool capable of removing a great deal of water from most environments Care must be taken to avoid secondary damages of over drying and or unexpected condensation Your Phoenix D385 removes vapor water from the incoming process air stream Fig 1 and transfers it to the outgoing reactivation air stream Fig 2 The reactivation exhaust air is hot and wet NCAUTION Take care to prevent the reactivation exhaust air stream from causing secondary damage due to condensation If the reactivation exhaust air stream cools below its dewpoint liquid water will condense inside the duct work creating puddles If the reactivation exhaust air stream is not exhausted completely from the structure it can also cause secondary water damage Your Phoenix D385 does not produce liquid water internal to the machine There is no condensate pump and no drain hose The D3
11. od Therma Stor uc PO Box 8680 Madison WI 53708 Phoenix D385 Owner s Manual WG PHOENIX RESTORATION EQUIPMENT Installation Operation amp Service Instructions Read and Save These Instructions The Phoenix D385 provides the perfect combination of features and performance the restoration industry has been craving in a desiccant dehumidifier Designed to operate vertically or horizontally the Phoenix D385 provides the wide operating range and ultra low grains of a desiccant with the water removal capacity of the largest LGR s in cabinet dimensions identical to our popular Phoenix 200 Max The D385 delivers 385 CFM of ultra low grain process air and removes an incredible 116 pints per day at AHAM conditions The true four hole configuration allows the Phoenix D385 to be located in the affected area with the 75 CFM re activation air stream isolated from the drying chamber Three hole designed units inherently pull unaffected and or outside air into the drying chamber The D385 s four hole design allows the restoration contractor to set up for effective positive neutral or negative pressure operation Able to operate vertically or horizontally the D385 will fit inside most crawlspaces Having the D385 securely inside rather than outside the crawlspace access deters the The Phoenix D385 Desiccant Dehumidifier Ultra low grains Wide operating range 116 pints per day AHAM Operates vertically or hor
12. r must be present to perform some tests these tests should be performed only by a qualified service person 4 1 Warranty A warranty certificate has been enclosed with this unit read it before any repair is initiated If a warranty repair iS required call the factory first at 1 800 533 7533 for warranty claim authorization and technical assistance 5 Wiring Diagram PROCESS REACT BLOWER CAPACITOR HEATER 1 12 OHMS REACT BLOWER 4026793 A Ai Therma Stor uc 12 OHMS PO BOX 8050 MADISON WI 53708 1 800 533 7533 LABEL PART NO REV BLU Figure 5 Electrical schematic of Phoenix D385 www usephoenix com sales thermastor com 6 Service Parts List Item 1 O ON ODO OB WN PRPRPRRRPRRPRRB RB OONOODOOBWNHRO Toll Free 1 800 533 7533 6 Part No 4025076 4025224 4026784 4026315 4026798 4026799 4026777 4926898 4026830 1970010 4026773 4026795 4026772 4026866 4021475 4026194 4025043 4026304 4024078 Description FAN MOTORIZED IMPELLER PROCESS AIR Item Part No CAPACITOR RUN 15 MFD 370V DRY PROCESS AIR Not 4025078 COLLAR SHORT 6 REACTIVATION DUCT 2 PLACES Shown FILTER AIR 12 X 12 X 1 REACTIVATION AIR Not 4026922 Shown FAN MOTORIZED IMPELLER REACTIVATION AIR HEATER CORE PHX D385 TOP COVER DESICCANT 385 THERMAL OVERLOAD CUT OUT SWITCH PROCESS AIR CAPACITOR RUN 8 MFD DRY REACTIVATION AIR CONTROL RELAY SPST 110VAC COIL 25AMP CONTACTS MOTOR DESICCANT WHE
13. rating This filter prevents loading the desiccant wheel with foreign matter Reactivation air stream filter This 12 x12 x1 filter is located in the bottom of your D385 To change the reactivation air filter lay the D385 down in a horizontal position The filter access slot is located on the bottom of the machine Fig 4 Open retainment clip remove old filter and replace with fresh filter The stock filter supplied carries a MERV filtration efficiency rating This filtration prevents plugging the heater or loading the desiccant wheel with foreign matter Operating the unit with a dirty filter will reduce the dehumidifier s capacity and efficiency and may cause the heater coil to cut out on thermal overload The filter can generally be vacuumed clean several times before needing replacement Replacement filters can be ordered from the factory or purchased locally if available DO NOT operate the unit without the filters or with less effective filters as the desiccant wheel inside the unit will become clogged and require disassembly to clean Retainment Clip Figure 4 Reactivation Filter Toll Free 1 800 533 7533 4 Service CAUTION CAUTION Servicing the Phoenix D385 with its high voltage circuitry presents a health hazard which could result in death serious bodily injury and or property damage Only qualified service people should service this unit CAUTION ELECTRICAL SHOCK HAZARD Electrical powe
14. t it overlaps the outside of the collar The duct and collar quickly attach to the D385 by snapping over the four screw posts surrounding the process air exhaust Fig 1 P3 Reactivation in amp out 6 flex duct Both reactivation air streams use the same type of duct connections The 6 flex ducting connections on the D385 consist of a detachable 6 starting collar Slide 6 flex ducting over the starting collar and zip tie or duct tape in place To remove the starting collar and its attached ducting length depress the snap button and rotate the duct collar 15 clockwise After rotating pull the duct collar straight out from the cabinet Flex duct and collar may be stored beneath top cover www usephoenix com sales thermastor com 2 8 Storage and Transportation The Phoenix D385 can be transported and stored in either upright or horizontal positions There is a storage compartment under the top cover of your dehumidifier This compartment is large enough to store reactivation collars power cords filter as used as well as additional small items that you may require on your job site 3 Maintenance 3 1 Air Filter Replacement The Phoenix D385 is equipped with two pleated fabric air filters that must be checked regularly Process air stream filter This 16 x20 x2 filter is located in the top of your D385 underneath the top cover The stock filter supplied carries a MERV 114 filtration efficiency
Download Pdf Manuals
Related Search
Related Contents
K892M - LJ-System automatismes OM, Solar Mower, 2001-01 pdf, 2 MB, 42 pages - CAPRI Modelling System LG LL2323T User's Manual Haier Washer HWM60-918NZP User's Manual Modelos TIPO 2 Electronic Submission of Forms on the Internet Guida per l`utente Opal 2006- 2006S- 2011 Copyright © All rights reserved.