Home
        User Manual
         Contents
1.       21    Servicing    Repairs  If a defect occurs  always return the complete S5 Endo Motor  due to the fact that with malfunctions  an inspection of all  components is necessary     Returns     gt  Refer all questions to your authorized service organization  see page 33     gt  Always return equipment in the original packaging     28    15  Sendoline Accessories                                            Use only original Sendoline accessories   spare parts  or accessories approved by Sendoline                1100001 1100002  Drive handpiece Contra angle head                                     1100003  Charging station                      1100006 301    Handpiece holder W8 amp H Assistina  1100005  Universal adaptor for  maintenance units     S             10940021  W amp H Service Oil F1   MD 400  02038200  Spray cap with nozzle  for contra angle  handpieces    1100004  Rechargeable battery  Li lon 3 7 V    29       16  Technical data    Drive handpiece EB 3SH  rechargeable battery type   mains voltage   rated capacity     rotational speed on root canal instrument     dimensions  WxDxH    weight     Charging station   mains voltage    allowable voltage fluctuation   frequency    rated current    power    dimensions  WxDxH    weight     Li lon   3 7 V   680 mAh   300 rpm   setting I max  4 0 Ncm  setting 2 max  3 0 Ncm  setting 3 max  2 3 Ncm  setting 4 max  1 2 Ncm  setting 5 max  0 5 Ncm  140 x 28 x 26 mm   85g    100   240 V       10     50     60 Hz  0 08   0 12 A  
2.       Charging station        Description Remedy       Charging control LED  charge  flashes orange  Remove and reinsert the drive handpiece        Check that the mains cable is plugged in and that the    No LED illuminates  power switch is set to ON  I               If one of the error messages described above cannot be rectified by remedy  the equipment must be checked by  a service and repair organization authorized by Sendoline  see Page 33         26          14  Servicing    A    Regular checking of the S5 Endo Motor  Regular testing of function and safety is necessary  and should be carried out at least once every three years   unless shorter intervals are prescribed by law  The inspection must be undertaken by a qualified organization and  needs to include the following procedures     Charging station   gt  visual inspection for outside damage   gt  measurement of housing leakage current   gt  visual inspection of internal components and electronic boards on suspicion of safety interference   e  g  mechanical damage of the enclosure or indicators for overheated or burned  electronic  components    Drive handpiece   gt  visual inspection for outside damage   gt  visual inspection of internal components and electronic boards on suspicion of safety interference   e  g  mechanical damage of the enclosure or indicators for overheated or burned  electronic  components    We recommend that this inspection is only carried out by an authorized service organization  See page 33
3.      Test run    gt  Insert root canal instrument     gt  Start the drive handpiece     gt  If you observe problems  e g  vibrations  unusual noise or excessive heating  stop operation of the drive  handpiece immediately and contact an authorized service organization  see page 33      15    9  Operating     Adjust torque             Adjust the torque     Start or stop the drive  Ker Preset torque is handpiece with the button  characterized by the motor ON   OFF     illuminated LEDs  am If you press the motor  ON   OFF button for    more than approx    1 second  the drive  handpiece will stop  auto matically when  you let go     Kee  gt  For information about the torques to be set  see the attached torque overview or sendoline com    gt  The torque can only be set when the drive handpiece is stationary    gt  The last torque setting is saved    gt  The drive handpiece switches off after it has been idle for 4 minutes    gt  When the battery capacity display begins to flash  a minimum of one more application is possible  After this  appears  Sendoline recommends that the battery should be recharged immediately as otherwise it cannot be  ensured that the torque values will be achieved                          Adjusting torque sequence  from low to high torque           Press the torque settings button for approx  10 seconds   Ker The middle 3 LEDs flash after 5 seconds       The change in torque sequence is saved when the 2 outer LEDs flash   T To change the factory set torque s
4.     KP Sendoline recommends processing in a thermo washer disinfector   Follow the manufacturer s recommendations for devices and cleaning agents       Lubricate contra angle head immediately after thermo washer disinfection     Daily oil service with W amp H Service Oil F1  MD 400   gt  Follow the instructions for use of the oil Spray can        23    Hygienic maintenance       Daily oil service service with W amp H Assistina    gt  See instructions for use of Assistina       Push the universal adaptor onto the contra angle head      Assemble   remove the appropriate adaptor onto the maintenance  attachment of the Assistina       Push the button and remove the universal adaptor from the contra   angle head     Recommended lubrication cycles  W amp H Service Oil F1 und Assistina    gt  Essential after internal cleaning    gt  Before each sterilization   or    gt  After 30 minutes of use or    gt  At least once daily    Test run following oil service     Push the contra angle head onto the drive handpiece      Place the contra angle head with head downwards       Run the drive handpiece for 30 seconds to remove excess oil     gt  Repeat the entire hygienic maintenance process if dirt emerges       Wipe the contra angle head and the drive handpiece with gauze or  a soft cloth     24    Hygienic maintenance    Sterilization and storage  F amp F Sendoline recommends sterilization according to EN 13060  class B     gt  Note the instructions of the unit manufacturer     gt  Clean  
5.    All packaging materials have been selected according to environmental compatibility and disposal aspects and can be  recycled  Please send old packaging materials to the relevant collection and reprocessing system  In this way  you will  contribute to the recycling of raw materials and the avoidance of waste     32    Sendoline Contacts    SED    Sendoline AB  Box 7037 Tillverkarvagen 6 SE 187 11 Taby Sweden  Phone   46  0 8 445 88 30  Fax   46  0 8 445 88 33  E mail  info sendoline com    33    Letter of indemnity    This Sendoline product has been manufactured with great care by highly qualified specialists  A wide variety of  tests and controls guarantee faultless operation  Please note that claims under warranty can only be validated  when all the directions in the Instructions for Use have been followed     As manufacturer  Sendoline is liable for material or manufacturing defects within a warranty period of  12 months from the date of purchase for the drive handpiece  contra angle head  charging station and the  rechargeable battery Li lon 3 7 V     We accept no responsibility for damage caused by incorrect handling or by repairs carried out by third parties not  authorized to do so by Sendoline     Claims under warranty   accompanied by proof or purchase   must be sent to the vendor or to an authorized  Sendoline service point  The provision of service under warranty extends neither the warranty period nor any other  guarantee period     12 Months Warranty    Manufa
6.  12    6  Starting operation     Charging station                Place the drive handpiece  in the charging station   Cam Note the positioning   All the drive handpiece  LEDs light up briefly     Oh Connect the mains cable                               Turn on power switch     Rechargeable battery is  F The green control LED charging    power  Comes on  FT Orange charging    MA control LED  charge   Ee  L   SA comes on                          Cam  gt  The drive handpiece can remain in the switched on charging station until it is next needed    gt  Fully charge the battery prior to initial use  This process takes approx  100 minutes    gt  The rechargeable battery is fully charged when the orange LED goes out     13    7  Starting operation   Assembly   removal of the contra angle head       Only change the contra angle head when the drive handpiece is stationary           Push on the contra angle head by applying slight axial pressure  position  selectable        Remove the contra angle head by applying slight axial tension                 14    8  Changing the root canal instrument       Only change the root canal instrument when the drive handpiece is at a complete standstill             Push in the root canal    Remove the root canal  instrument as far as the We instrument by pushing the  locating lug  a  and turn JA press button     JA   Xx m     until it engages  b    ei      Check secure location by  applying slight axial  EZ tension     NA                             
7.  5 W   95 x 159 x 65 mm  345 g    30    Technical data    Contra angle head EB 16S  transmission ratio    coupling typ    recommended root canal instrumente    Instrument shaft diameter  type 1  in  accordance with EN ISO 1797 1 1995   min  chuck length    weight     16 1  Sendoline coupling  files for rotating root canal preparation for min  300 rom       2 35 mm       engaging  35 g     In choosing the correct operating conditions  the user must ensure that there is no risk to the user  the patient or third  parties  Always follow the instructions of the manufacturer of the root canal instruments  e g  in terms of speed  torque     described application      Physical characteristics  Temperature in storage   Air humidity in storage     Temperature in operation   Air humidity in operation      40   C   40   F  to  70   C   158   F   8   to 80    relative    non condensing at  40   C   104   F    10   C   50   F  to  40   C   104   F   15   to 80    relative    non condensing at  40   C   104   F     31    Technical data    Recycling  Sendoline considers that it has a special duty towards the environment  The S5 Endo Motor along with its packaging has  been designed to be as environmentally friendly as possible     Disposal of the S5 Endo Motor  charging station   drive handpiece   rechargeable battery   contra angle head   Follow your country specific laws  directives  standards and guidelines for the disposal of used electrical devices     Disposal of the packaging material
8.  7 V     in the condition as delivered by us  This declaration is not valid for unintended external or internal attachments  and similar     Sendoline AB in T  by  Sweden can only accept responsibility for the safety  reliability and performance of the   S5 Endo Motor when there is compliance with the following directions     gt  The S5 Endo Motor must be used in accordance with these Instructions for Use     gt  The S5 Endo Motor contains no parts which are repairable by the user  Assembly  modifications or repairs must  be carried out only by an authorized service organisation  see page 33      gt  The electrical installation at the premises must comply with the international regulations of IEC 60364 7 710    Electrical installations of buildings     Part 7 710  Requirements for special installations or locations     Medical  locations   or with the regulations applicable in your country       Responsibility of the manufacturer    HF Communication Devices  During operation  please do not use any portable or mobile high frequency communication devices  such as  mobile telephones   These can have a negative effect on electrical medical devices     2  Equipment supplied    After unpacking the following parts should be present     REF 1100010   O drive handpiece REF 1100001   O contra angle head REF 1100002   O charging station REF 1100003   O rechargeable battery Li lon 3 7 V REF 1100004    O mains cable REF 05464400  Europe     alternative specification   O mains cable REF 05
9.  and drive handpiece may be wiped clean      gt  For disinfection with surface disinfectants  wiping disinfection is recommended     gt  Use only surface disinfectants which do not contain chlorine and which are certified by officially recognized institutes   For USA  Use EPA registered surface disinfectants     gt  Note the manufacturer   s specifications for the use of the surface disinfectants     21    Hygienic maintenance    contra angle head    Pre disinfection   gt  If heavily soiled  Clean first with disinfectant cloths     T Only use disinfectants that have no protein fixing effects        Manual cleaning  internal and external      Rinse under demineralized water   lt  38   C  with the aid of a brush  brushing  under running water is not recommended in U K       Then remove any liquid residues  absorbent cloth  blow dry with  compressed air               Manual disinfection    gt  Disinfection with surface disinfectants    wiping disinfection is recommended     gt  Use only surface disinfectants which do not contain chlorine and which are  certified by officially recognized institutes  For USA  Use EPA registered  surface disinfectants     gt  Note the manufacturer   s specifications for the use of the surface disinfectants                 After manual cleaning  disinfection and lubrication you must carry out a final sterilization  wrapped  in a class B or  S steam sterilizer  according to EN 13060   Se    Hygienic maintenance    Mechanical cleaning and disinfection
10. 456100  USA  CAN  J    REF 05457700  UK  IRL    REF 05467600  AUS  NZ     3  Safety notes    A    A  A    It is essential to comply with the following instructions    gt  Always ensure the correct operating conditions     gt  Perform a test run prior to each use     gt  Only use REF 1100002 Sendoline contra angle head     gt  Only insert the contra angle head when the drive handpiece is stationary     gt  Check the contra angle head for damage and loose parts prior to use  e g  press button      gt  Never touch the press button of the contra angle head during use or while slowing down  This can cause  loosening of the root canal instrument or the press button to become hot     gt  Avoid contact between the instrument head and soft tissue  danger of burning due to the press button heating  Up      gt  Use only perfect root canal instruments and follow the manufacturer s instructions     gt  Only insert the root canal instrument when the contra angle head is stationary     gt  Never touch root canal instruments while running or slowing down     gt  The drive handpiece should only be placed in the holder as it may heat up  Do not place it on the patient   s body     gt  Sendoline recommends the use of rubber dam     gt  Store drive handpiece and charging station for 24 hours at room temperature before starting operation     Hygienic maintenance prior to initial use   The items are in a clean condition when delivered     gt  Sterilize and lubricate the contra angle head     gt  d
11. Sendoline    Instructions for use of S5 Endo Motor       Sendoline Symbols    A A e    WARNING  ATTENTION  General explanations    Risk of injury   to prevent damage occurring  without risk to    persons or objects          135C  T 555    Thermo washer disinfectable Sterilizable  up to the stated temperature    Sendoline Service    Only for USA   Caution  Federal law restricts this device to sale by or on the order of a dentist   physician or any other practitioner licensed by the law of the state in which he  or she practices to use or order the use of the device     Sendoline Symbols  Symbols on rechargeable battery   charging station   contra angle head   drive handpiece    pH Consult Instructions for use X Do not dispose of in general REF Catalogue number                waste  E  SN Serial number  V Supply voltage  Class II equipment i  Data Matrix Code    electric insulating    for product identification e g  AC Alternating current  in hygienic maintenance  Process W Electric power input of the  unit  Date of manufacture este Classification mark  A Supply current  iv d   that this product is in  compliance with the   Hz Frequency of the alternating  American and Canadian current      SSES rom Revolutions per minute  A Not suitable for intracardiac  application   Type BF mAh Milliampere hours    appliance    Ncm Newton centimetres    Contents    ele eine EE 2  1  194 2050 Eed Le EE 5  2  F  L PMENESUPPIG OG WE T  EE e 8 10  4  Description     Charging station EE 11  5  De
12. cturer    Sendoline AB  Box 7037 Tillverkarv  gen 6 SE 187 11 T  by Sweden    t  46  0 8 445 88 30  f  46  0  8 445 88 33  e info sendoline com sendoline com    ISO 13485   93 42 EEC     Annex II    Form Nr  50632 AEN  Rev  002   12 10 2009  Subject to alterations    
13. disinfect and lubricate before sterilizing     gt  Wrap the contra angle head in sterile goods packing according to EN 868 5    gt  Make sure that you only remove dry sterile goods     gt  Store sterile goods dust free and dry     Approved sterilization procedures  Ke Follow your country specific directives  standards and guidelines      gt  Steam sterilization class B with sterilizers in accordance with EN 13060   Sterilization holding time a minimum of 3 minutes at 134   C  273 2   F    or    gt  Steam sterilization class S with sterilizers in accordance with EN 13060   The manufacturer must give their express approval for the sterilization of contra angles   Sterilization holding time a minimum of 3 minutes at 134   C  273 2   F     25    13  Description of failure   Remedy    Drive handpiece        Description Remedy       The drive handpiece cannot be activated  The rechargeable battery is empty  Charge or change it        Restore factory settings   press and hold the torque  settings button for approx  15 seconds  After the first   5 seconds the middle 3 LEDs flash  after a further   5 seconds the 2 outer LEDs flash and after a further   5 seconds only the middle LED continues to flash  this  indicates that the factory settings have been restored      Internal error   all 5 LEDs on the torque display are flashing        System failure Disconnect   Connect the rechargeable battery   The rechargeable battery heats up excessively  Change the rechargeable battery           
14. equence again  from high to low torque   repeat  this process              16       10  Operating     Auto Forward and Auto Reverse mode    The factory setting is Auto Forward mode           If the preset torque is reached  the drive handpiece continues running in an anti clockwise  direction so that the root canal instrument becomes free and then it runs in a clockwise  direction                 If the preset torque is reached  the drive handpiece continues running in an anti clockwise  direction so that the root canal instrument becomes free and then it stops              17    Operating     Auto Forward and Auto Reverse mode          T If more than 75   of the preset torque is reached  the control LED ring for torque    lights up           Conversion to Auto Reverse mode             Press the torque settings button for approx  5 seconds     When the middle 3 LEDs flash the mode change is saved   T The last torque set is retained              T Repeat the procedure in order to change back to the Auto Forward mode     Restore factory settings  Press and hold the torque settings button for approx  15 seconds   The LEDs flash in a particular sequence  see page 26  and afterwards the factory setting has been restored   18    11  Exchanging the rechargeable battery  T Replace the battery if power fails relatively quickly after a full charge     A In order to avoid damaging the device  one should avoid opening the battery cover unnecessarily             Take the cover off     Ins
15. ert the new  rechargeable battery   Connect the plug  contacts     Kee Note the positioning                                   Close the cover   Cn Note the positioning        Disconnect the plug  contacts  Take the  rechargeable battery out                             19    12  Hygienic maintenance    CS    A    Follow your country specific directives  standards and guidelines for cleaning  disinfection and sterilization      gt  Wear protective clothing   Remove the root canal instrument    gt  Remove the contra angle head from the drive handpiece     V     gt  Clean and disinfect the contra angle head immediately after every treatment to rinse out any liquids that may  have entered  e g  blood  saliva  etc   and prevent seizing up of the internal parts    gt  Clean and disinfect the drive handpiece immediately after every treatment      gt  Sterilize the contra angle head following manual or mechanical cleaning  disinfection and lubrication      gt  The charging station and drive handpiece are not approved for mechanical cleaning  thermo washer  disinfection  and sterilisation     20    Hygienic maintenance    Charging station and drive handpiece     N  gt  The mains cable of the charging station must not be connected    gt  Do not submerge the drive handpiece and the charging station or clean them under running water     Pre disinfection   gt  If heavily soiled  Clean first with disinfectant cloths     Manual cleaning and disinfection  T The surface of the charging station
16. harging station for mechanical preparation of the root canal  The application area extends to  endodontic procedures using a special root canal instrument which is intended by the manufacturer for use in the  mechanical and rotary preparation of the root canal    Misuse can damage the S5 Endo Motor and involves risk and danger to the user and third parties     User qualifications  In the development and design of the S5 Endo Motor  we have assumed the target group of users to be dentists     Skilled application   This medical product is intended only for informed use in the medical dental field  according to its purpose of use in  compliance with the valid health and safety at work regulations  the valid accident prevention regulations as well as in  compliance with these Instructions for Use  The S5 Endo Motor should be maintained according to the manufacturer s  recommendations and in line with infection control procedures for the safety and well being of patients  Improper use  e g   poor hygienic maintenance  or non compliance with our Instructions or the use of accessories and spare parts which are  not approved by Sendoline  invalidates all claims under warranty and any other claims     Introduction    C     Production according to EU directive  This medical product has been designed and manufactured according to EU Directive 93 42 EEC  0413 and is valid for the     gt   5 Endo Motor  charging station  drive handpiece  contra angle head and rechargeable battery Li lon 3
17. isinfect the drive handpiece and charging station prior to initial use  see page 20   25      Inappropriate use  Improper use  in addition to incorrect assembly  installation  modification or repairs of the S5 Endo Motor or  non compliance with our instructions invalidates all claims under warranty and any other claims  8    Safety notes     gt  The rechargeable battery Li lon 3 7 V is not sterilizable     gt  Only use REF 1100004 Sendoline rechargeable batterys  Using a different model of battery can cause a fire or  explosion     gt  Only use the Sendoline rechargeable battery REF 1100004 in connection with the Sendoline drive handpiece  REF 1100001 and the battery charging station REF 1100003     gt  The rechargable battery used in the device can cause a risk of fire or acid burns if it is not used properly  e g   charging in a charging station other than the one provided      gt  The battery may not be dismantled  heated to above 100   C  212   F   or burned     gt  Defective or disused rechargeable batteries must be immediately disposed of in the correct manner     gt  Keep the rechargeable battery out of the reach of children     It is essential to comply with the following instructions when using the rechargeable battery     The S5 Endo Motor  charging station   drive handpiece   The unit is classed as  conventional equipment   closed equipment without protection against the ingress of water      System failure  A total system failure of the S5 Endo Motor does not cons
18. scription     Drive handpiece   Rechargeable battery   Contra angle head A 12  Ge Staring operation   Charging  Statii DE 13  7  Starting operation     Inserting   removing contra angle head mnsesesssssresrrrsrrrsrrrrrrrrrrrrrrrr ran rrrrr rr rr rr KKR KKR KKR RR KR KKR RR SRA Kan 14  6 Changing he TOC Canal in E dE 15  I et ae SESE rer RTE 16  10  Operating     Auto Forward and Auto Reverse mode sunssmesrrssrrsrrrsrarsrrsrrrrrrrnrrrrr rss rank rr RAR RKA KKR RR KRA RKS RR RR KKR R RAR nn 17 18  11  Changing the rechargeable battery un 19  12  Hygiene  mantenanCeE  ssctesatetssactse state tucsetoneiden a bir   ss is Os d  r se see RUN   DK ERS RER NE KK br Eb   R RANE   KE FN 20 25  13  Descriplon of Tare e EE 26  TA FE lee  e BEE 21 28  Eeler ee e 29  Io Teme E e e ME 30     32   SEMOOMME CONACIS asben epea EE E NEEE EEES E AEEA EIE TOERE E RETES E isl scoenetaasccimeudsananedelanadun IRENE 33   Lenor OF maorin liy E 34    1  Introduction    These instructions explain to you how to handle your Sendoline product  However  we must also warn against  possible hazardous situations  Your safety  the safety of your team  and of course  the safety of your patients is  of paramount importance to us     f For your safety and the safety of your patients    A N It is therefore essential to read the safety notes on pages 8 to 10     Intended use   The Sendoline S5 Endo Motor is a modular electrical system comprising a drive handpiece  a rechargeable battery  a  contra angle head and a c
19. titute a critical fault     The charging station has been adjusted to fit the Sendoline drive handpiece  The use of other charging stations    drive handpieces could lead to irregularities or destruction of the electronic system   rechargeable battery     atmospheres or in potentially explosive mixtures of anesthetics with air  oxygen or nitrous oxide  or at locations      According to IEC 60601 1   UL 60601 1  the S5 Endo Motor must not be used in potentially explosive  where concentrations of such gases could occur  closed rooms         Safety notes       The    patient zone     see diagram  represents an area of 2 50 m  above and 1 83 m around the patient        Do not use the charging station in the patient zone           n E M E ES T i Sy a          10    4  Description   Charging station          charging slot for       drive handpiece       control LED  power  0  ON  green  S    charging control LED  charge    orange     power socket       power switch  ON   OFF  I   0           11       5  Description     Drive handpiece   Rechargeable battery   Contra angle head       Sendoline coupling for contra angle head a   gt     button for   unit ON and  motor ON   OFF          control LED ring for torque    torque display  setting 1   4 Ncm max 2400 gem    button for   unit ON and  torque settings       rechargeable battery   Capacity display       charging contacts       rechargeable  battery cover                press button       plug contact into  drive handpiece         
    