1. AC 2000 PLU SCALE OPERATOR MANUAL AC2000 USER MANUAL INDEX Description Page Number Applying Power to the Scale Loading Labels Key Board Operation Display Indicators Key Switch Operation Zeroing the Weight Display Tare Entry Manual Entry Preset Tare Tare Look Up PLU Programmed Tare Basic Operation Weighed Item Non Weighed Item Bakery Auto Manual Label Printing Save Mode Program Value Over ride Unit Price Pack Date FOR Key Oooaa skhAA ASB O OnMmNM ONN APPENDIX A WEIGH CHECK AC2000 User Manuai Index 4 1 0 APPLYING POWER TO THE SCALE Make sure nothing is on the platter Make sure the key switch is turned to the ON LINE or OFF LINE position Turn the POWER switch located on the left side of the scale to the on position NOTE If something is on the platter REMOVE THE ITEM ON THE PLATTER is displayed 7 INITIAL POWER SCREEN After a few seconds OPERATOR SCREEN 2 0 LOADING LABELS 1 Remove the label cassette by pulling outward Thread the label according to the instruction drawing inside the labe cassette Remove U pin Pull U Pin out and reinsert it over the end of the label so that the label is attached to the take up spool Gently slide the label cassette fully back into the main body AC 2000 User Manual page 1 6 Press the FEED key to advance the label to the correct position NOTE if using continuous strip pressing the FEED key advances only 1 2 i
2. Mode the label is issued when the weight stabilizes 3b In Manual Mode it is required to press the PRINT key to obtain a label AC 2000 User Manual page 5 ii NON WEIGHED ITEM BAKERY 1 Key in the PLU number and press the PLU key or press the PRESET key PLU SELECTION BAKERY ITEM 2 Press the PRINT key to obtain a label 8 0 AUTO MANUAL LABEL PRINTING When set to AUTO a label will automatically be issued every time a package is placed on the platter and the weight has stabilized When set to MANU the PRINT key must be pressed to obtain a label d Press the AUTO MANU key to select the desired mode The AUTO indicator will illuminate when the scale is in AUTO mode 9 0 SAVE MODE 1 Press the AUTO MANU key to enter the MANUAL mode if it is the AUTOMATIC mode 2 Select the desired PLU if not already displayed 3 Press the SAVE key indicated when the SAVE indicator is illuminated NOTE a When the SAVE indicator is illuminated the PLU selected is retained SAVED after a label is printed b Press the SAVE key again to cancel the SAVE mode AC 2000 User Manual page 6 10 0 PROGRAM VALUE OVERRIDE UNIT PRICE LB OVERRIDE This feature only operates if the AC 2000 is configured with this option at installation Select the desired PLU if not already displayed By PLU key or numeric entry Key in the desired unit price Place a package on the scale platter Press the PRINT key t
3. akery Print 1 PLU PROGRAMMING Ts Sales Mode 2 Weigh Check 2 Fixed Weight oz check weight value OPERATION 1 Key ON LINE or OFF LINE 2 Weight must be at ZERO no tare weight 3 Select PLU 4 Place product on scale 5a Press key 6 a Actual Weigh gt Check Weight z Label is printed with progammed check weight value b Actual Weight lt Check Weight Operator is prompted to accept actual weight or cancel printing Ta Press lo PLU keys to clear PLU or select next PLU This feature is designed for use in a bakery environment If BAKERY PRINT with Sales Mode 1 in label format PLU s programmed o will not print i
4. ccessed by inserting either the operator key or the master key and rotating the key The master key can access all positions and the operator key can access all but the SET UP position The keys can be removed in the on line or off line position Each position of the key switch accesses a different scale mode SET UP SUB OFF LINE ON LINE REG TOTAL SET UP mode Accesses the mode used for setting the initial data settings ie label format etc SUBTRACTION mode Access the mode used to manually subtract returns from the recorded PLU totals NORMAL OPERATION In the off line mode the PLU data is not accessed from the master scale in a system the scale operates as a stand alone machine NORMAL OPERATION In the on line mode the PLU data is accessed from the master scale PROGRAM mode Access all modes used to program data for label printing TOTALIZATION mode Access modes to allow the display and print out of PLU total information Set the key switch to the desired position and refer to the corresponding chapter of this manual for instructions 6 0 NORMAL OPERATION 6 1 ZEROING THE WEIGHT DISPLAY i Make sure that nothing is on the weigh platter 2 Press the ZERO key AC 2000 User Manual page 3 6 2 TARE ENTRY There are four ways to enter a tare value manual tare preset tare tare look up key and PLU programmed tare 1 MANUAL TARE Make sure that nothing is on the platter and check that th
5. e weight display pads zero If not zero press the ZERO key Place the item to be tared pack or container on the weigh platter The weight of the tare item will be displayed Press the TARE key The displayed weight value will be return to zero and the TARE indicator will be illuminated If the weight display does not return to zero after pressing TARE the scale has not yet stabilized Let the scale stabilize for a few seconds and then press TARE again The scale is now tared Note that the weight value will become a minus value if the tared item is removed from the platter PRESET TARE Make sure that nothing is on the platter and check that the weight display reads zero If not zero press the ZERO key Key in the desired tare value and press the TARE key The tare value will be displayed as a negative weight TARE LOOK UP KEY Make sure that nothing is on the platter and check that the weight display reads zero If not zero press the ZERO key Press the preset key which is programmed with the desired tare value PLU PROGRAMMED TARE Please refer to the programming menu AC 2000 User Manual page 4 7 0 BASIC WEIGHING LABELING OPERATION i WEIGHED ITEM 1 Key in the PLU number and press the PLU key or press the appropriate PRESET key NOTE Please refer to the section HOW TO ASSIGN PRESET KEY in the programming manual PLU SELECTION 2 Place a package on the scale platter PLU SELECTION 3 In Automatic
6. hen the label is printed with the new price PONZ PACK DATE OVERRIDE 1 Select the desired PLU if not already displayed as above PLU SELECTION WEIGHED ITEM 2 Press the DATE key DATE CHANGE OPTION SCREEN 3 Change the pack date as follows a date DD key in 2 digits then press SET b month date MMDD key in 4 digits then press SET c year month date YYMMDD 6 digits then press SET AC 2000 User Manual page 7 a c EX Change to May 1 1991 Key in 910501 then press the SET key TEMPORARY DATE SCREEN Press the DATE key PLU SELECTION SCREEN NOTE The display still indicates APR 15 91 but the printed label shows the pack date MAY 01 91 USE BY DATE is automatically changed If another PLU is selected the temporary date change is canceled AC 2000 User Manual page 8 11 0 HOW TO USE THE FOR KEY For example when a customer buys 10 pieces of PLU 3 appies at 1 00 5 pieces 1 Press 3 then press the PLU key or press the appropriate preset key 2 Enter 10 then press the FOR key 3 Enter 5 then press the FOR key PLU SELECTION FOR OPERATION Beate AC 2000 User Manual page 9 4 5 Key in 100 then press the SET key Press the PRINT key to print a label AC 2000 User Manual page 10 Yv ISHIDA gt II III NOTE ISHIDA AC 2000 WEIGH CHECK OPERATION SET UP To Label Format B
7. n of label This is to allow a clean edge to be obtained by tearing off the excess 3 0 KEYBOARD OPERATION 0 9 C SET PLU ZERO TARE AUTO MENU FEED PRINT DATE SAVE FOR Enter numbers ie PLU number and or Tare value Clear an incorrect numerical value key before the SET key is pressed Enter a numerical value into the scale Select a PLU after the PLU number has been entered by the numeric keys Adjust the scale to zero Set tare value after the numeric keys have been pressed or automatically Select automatic or manual label printing Issue a blank label or feed a length of continuous strip Issue a complete label Temporarily change the packed date Enter or escape from prepack mode where the PLU and tare value is saved Ex when a customer buys 5 pieces of PLU 1 1 00 3 pieces Press 1 then PLU Press 5 then FOR Press 3 then FOR Enter 100 then SET SHIFT Select the lower preset keys PRESET RESET Select programmed PLU Tare or Operator Reset the scale to the power on menu 4 0 DISPLAY INDICATORS ZERO NET SAVE AUTO Iluminated when no weight is on the platter Illuminated when a tare is set illuminated when save mode is entered IIltuminated when automatic print mode is entered AC 2000 User Manual page 2 5 0 KEY SWITCH OPERATION The key switch is located at the left side of the scale housing The key switch has six positions Each position can be a