Home

Implementation of the Regulatory Authority

image

Contents

1. Using this system the RAN for Alexandria is 01 the RAN for Samoha is 0101 the RAN for Alexandria International Hospital is 01010001 the RAN for the Shirana instrument is 0101000101 and the barcode RANSs for the three sources associated with this instrument are 010100010101 010100010102 and 010100010103 DATA SHARING RAIS will be implemented in Egypt at the MOHP EORP and will contain data on both RSS that are in use and those that are in storage either for possible future use or awaiting disposal Different agencies will require various levels of access to RAIS to be able to effectively perform activities associated with RSS The EORP is responsible for the update and maintenance of the database The EAEA needs to be able to access data for spent RSS i e those in storage for disposal update specific RAIS data fields source status and source location as sources change status from in use to in storage and input audit data when facility audits are conducted The Egyptian Customs Authority needs read only access to be able to track RSS imports and exports Using the RAIS 3 0 Creator software module and the procedures outlined in the RAIS 3 0 Administrator s Guide the EORP will create the RAIS user interfaces with the EAEA and customs the RAIS 3 0 front end and the database RAIS 3 0 back end The EORP will then freeze the front end so that it can only be modified by authorized MOHP s
2. Protection EORP and the Egyptian Atomic Energy Authority EAEA to protect human health and the environment in Egypt from Sandia is a multi program laboratory operated by Sandia Corporation a Lockheed Martin Company for the United States Department of Energy s National Nuclear Security Administration under contract DE AC04 94AL85000 WM 06 Conference February 26 March 2 2006 Tucson AZ mismanaged RSS through development of comprehensive RSS management capabilities The program includes automating cradle to grave tracking of RSS in use and in storage through implementation of the I AEA s RAIS database RAIS is a hierarchical inventory and tracking system for RSS developed through the IAEA to provide member states with a common software for tracking and controlling RSS The RAIS structure is a top down hierarchy beginning with a country s regulatory infrastructure and focusing down through regions districts facilities and departments to individual radiation generators and associated equipment RAIS e Tracks authorization licensing import export use and disposal of RSS e Manages activities such as inspections and audits e Provides a template for RSS management that can be customized to meet the needs and regulatory requirements of individual countries e Is available on the Internet at ftp ftp 1aea org pub RAISLANG In order to completely automate RSS tracking in Egypt 1 software had to be developed that
3. S D A Primer on the Regulatory Authority Information System RAIS Database for Egypt Sandia National Laboratories White Paper Albuquerque NM 2004 2 Hasan A et al Integrated Management Program for Radioactive Sealed Sources in Egypt Proceedings from Waste Management 03 Waste Management Symposia Inc Tucson AZ 2003 3 Regulatory Authority Information System RAIS 3 0 Training Materials July 2004 4 Schetnan R RAIS PDA Application User s Manual Version 0 1 Revision 0 Beta Corporation International Albuquerque NM 2004 5 Working Material Regulatory Authority Information System RAIS 3 0 Documentation April 8 2004
4. other facility and department If no source is found in the system that corresponds to the scanned barcode a dialog box appears asking if a discrepancy should be logged Fig 3 RAIS PDA E _ Facility Facility 1 t not be found Log the discrepancy es Nal lal Fig 3 Discrepancy dialog Audit data may be provided for only those sealed sources that are associated with specific facilities and departments When Unassigned is selected in the Department list and a source WM 06 Conference February 26 March 2 2006 Tucson AZ regulatory authority number is selected with the stylus an error message will appear that says Source must be associated with a department before it can be audited To associate a sealed source with a department select a facility and department and scan the barcode for the source The source will be assigned to the selected facility and department and be highlighted in the list Once the source is assigned to a department and selected audit data may be provided for it THE RAIS BARCODE SYSTEM FOR EGYPT Under the RAIS hierarchical structure all regions districts facilities equipment and sources have a unique regulatory authority number RAN The barcode identity system shown in Fig 4 was developed for each step in the RAIS hierarchy as it relates to infrastructure organization in Egypt Under this system All regions the 27 Egyptian governorates or states hav
5. would allow two way communication between the RAIS database and a PDA and 2 a barcode identification system was needed that would uniquely identify all RSS in the country RAIS PDA APPLICATION The RAIS PDA Application is a software program that runs on a PalmOS PDA and Windows CE platforms The software provides an easy to use PDA interface to a RAIS database that allows users to verify RSS inventory data in the field perform audits and upload the data to the parent RAIS database Specifically the Application allows users to e Display RSS in the RAIS database by making selections from lists of facilities and departments that have sealed sources e Review the following information for each RSS in the RAIS database o Source identification number Primary radionuclide s Activity Facility Department Source category Physical form Chemical formula Expected location Status i e in use inactive or in storage Status date Responsible party Responsible party phone number e Provide audit data for selected RSS that includes o Whether the source passed its leak test o Leak test date 6 0 0 OO 0 OO O WM 06 Conference February 26 March 2 2006 Tucson AZ o Whether posting of the source is adequate o Whether the source is secure o Comments e Select a sealed source by scanning its barcode e Move a sealed source from one facility and or department to another by selecting the destin
6. WM 06 Conference February 26 March 2 2006 Tucson AZ Implementation of the Regulatory Authority Information System in Egypt S D Carson Sandia National Laboratories P O Box 5800 Albuquerque NM 87185 USA R Schetnan Compa Industries 1314 Madiera Drive SE Albuquerque NM 87108 USA A Hasan New Mexico Institute of Mining amp Technology Research Institute Albuquerque NM USA Y T Mohamed Egyptian Atomic Energy Authority 3 Ahmed El Zomor Street Cairo 11762 Egypt ABSTRACT As part of the implementation of a barcode based system to track radioactive sealed sources RSS in Egypt the Regulatory Authority Information System Personal Digital Assistant RAIS PDA Application was developed to extend the functionality of the International Atomic Energy Agency s AEA s RAIS database by allowing users to download RSS data from the database to a portable PDA equipped with a barcode scanner 1 4 The system allows users in the field to verify radioactive sealed source data gather radioactive sealed source audit information and upload that data to the RAIS database This paper describes the development of the RAIS PDA Application its features and how it will be implemented in Egypt INTRODUCTION The Integrated Management Program for Radioactive Sealed Sources IMPRSS 2 is a joint effort among Sandia National Laboratories SNL The Egyptian Ministry of Health amp Population MOHP Executive Office for Radiation
7. ation facility and department and scanning the barcode of the source e Log a discrepancy of a source barcode that is scanned but is not found in the RAIS database Hardware and Software Requirements The following hardware and software are required for complete interoperability between the RAIS PDA Application and a RAIS database Symbol model SPT 1800 PDA with cradle RAIS Database Creator Version 3 0 Palm Desktop Software JSync software for Palm Desktop Java XML conduit available from Digital Migration Inc Albuquerque NM Desktop computer capable of running RAIS Database Creator 3 0 and Palm Desktop software Limitations of the RAIS PDA Application In its current form the RAIS PDA Application does not provide any mechanisms for adding a sealed source sealed sources must be added to the system by using the RAIS database version 3 0 software Because data consolidation in the RAIS 3 0 software can cause significant data changes the RAIS PDA Application must be synchronized to its respective RAIS database immediately before and immediately following data consolidation to prevent data integrity problems Using the Software The RAIS PDA Application is launched by tapping on the RAIS icon in the applications window of the PDA with the stylus Using the Application involves a few steps e Selecting a facility Tap the arrow to the right of the facility drop down list and select the desired facility from the list by tapping it with the s
8. e a 2 digit RAN All districts Egyptian cities and towns have a 4 digit RAN region district All facilities have an 8 digit RAN region district facility All generators have a 10 digit RAN region district facility generator All sources have a 12 digit RAN region district facility generator source 01 RAIS Region one of the 27 Egyptian governorates 0101 RAIS district corresponds to an Egyptian city 01010001 Facility 0101000101 Generator or Associated Equipment 010100010101 Source Fig 4 The RAIS barcode identification system for Egypt Examples of the implementation of this system using data for Egypt are shown in Table I Table I Sample of Barcode RANs for In Use Medical RSS in Egypt Region District city Facility Generator Source Ol Alexandria 01 Samoha 0001 Alexandria Ol Shirana 01 Co 60 International 02 Co 60 Hospital 03 Cs 137 02 Asute 01 Asute 0001 Asute 01 C G R 01 Co 60 Oncology Center 02 C G R 01 Co 60 WM 06 Conference February 26 March 2 2006 Tucson AZ 0002 Prof Amina 01 Theratron 01 Co 60 Oncology Center 780 0003 South Egypt 01 Cs 137 Oncology Center 01 Blood irradiator 03 Cairo 01 Abassia 0001 Ein Shams 01 C G R 01 Co 60 Oncology Center 02 Nucletron 01 Cs 137 02 Cs 137 03 Cs 137 04 Cs 137 05 Cs 137 06 Cs 137 07 Cs 137 08 Cs 137 09 Cs 137 10 Cs 137 11 Cs 137 03 Blood Ol Cs 137 irradiator
9. ls Auditi Boneh o Fig 1 RAIS PDA Application source list left and source details right Oo0O000 0 Tap on the Yes or No radio buttons with the stylus to provide data about the leak test posting and source security By default all radio buttons are set to No if no audit data are available for the source If the leak test date is available it will be shown in the textbox otherwise the current date will be shown To change the leak test date tap the Date button to display a calendar from which another date can be selected If desired a comment of up to 50 characters may be entered in the Comment field To save the audit data tap the Done button otherwise tap the Cancel button to return to the main window WM 06 Conference February 26 March 2 2006 Tucson AZ RAIS PDA Reg Auth Mo 55 66 78 Leak Test Passed est Mo Leak Test DateJos 29 2004 Batel Posting Adequate e est Mo Source ls Secures e Yes Mo Comment Fig 2 Audit data window A source can also be selected by scanning the barcode of a source in the list If a RSS witha regulatory authority number that corresponds to the scanned barcode is found in the list of sources for the selected facility and department it is selected in the list and highlighted if the source is found in the list for another facility and department it is added to the list for the currently selected facility and department highlighted and deleted from the list for the
10. taff The RAIS system in Egypt will be a three site configuration with the EORP being the primary site and the EAEA and customs being the user sites As such the EORP will provide the EAEA WM 06 Conference February 26 March 2 2006 Tucson AZ and customs with the initial version of RAIS for Egypt Both the EAEA and customs will be able to modify back end data at their sites however it is anticipated that only the EAEA will make changes to source data as sources no longer in use are placed in storage Using the Consolidator function in RAIS 3 0 Creator the EAEA will then upload new back end data to the MOHP on a regular basis i e monthly Using these data the EORP will then create a new primary back end and re distribute this to the two user sites SUMMARY The IAEA has successfully developed and offered RAIS to over 50 countries Using RAIS with the ability to automatically track barcoded sources via the RAIS PDA Application provides e Rapid assessment of a country s high risk radioactive sources e The ability to perform completely automated RSS audits e Enhanced source security leading to increased public health and safety The EORP now has approximately 1 900 RSS in RAIS in both English and Arabic As the barcode based RAIS is implemented in Egypt the IMPRSS team will work with the IAEA to offer the RAIS PDA Application as an option for RSS tracking and inventory development in other countries REFERENCES 1 Carson
11. tylus e Selecting a department The above procedure is applied to the department drop down list When a new department is selected the list of regulatory authority numbers for the sources in the department appears in the source regulatory authority number list Fig 1 e Selecting a sealed source from the list or adding a sealed source from another facility or department Tap the source regulatory authority number with the stylus When the source is selected it appears in the list with a darkened background Fig 1 e Displaying the details for individual sources Select the source and tap the Details button to display the RAIS data for the source Fig 1 Use the arrows or scroll bar to scroll the list Tap on the Done button to return to the main menu WM 06 Conference February 26 March 2 2006 Tucson AZ e Providing audit data for selected sources Select the source and tap the Audit button This will display a window with controls for entering the following audit data Fig 2 Data on whether the source passed its leak test Leak test date Whether posting of the source is adequate Whether the source is secure Comments RAIS PDA RAIS PDA PDA Facility Building 23 Reg Auth Mo 55 66 78 Facility Building 23 Department Dept srd Dept 687d Source Regulatory Authority Humber zotopes Am 241 Activity 1 234 Ci Location Room 1234 Status Active Status Date 0102 03 Contact John Doe Phone 505 123 4567 x Detai