image

Contents

1. Display Languages 7 English ie 2 3 4 fie 6 ay Infrared Communication can be used only to download recorded data and not to make recording settings The following cables are necessary for serial communication with data loggers TR 6C10 included for TR 7Ui 7U series and TR 4C10 optional for TR 7S series and VR 71 The optional serial communication cable TR 07C is necessary for serial communication with PC Battery life varies depending upon the ambient temperature in which it is used the frequency of communication and the battery performance All estimates are based on operations carried out with a new battery and are in no way a guarantee of actual battery life For installation it is necessary to have Administrator Computer Administrator rights If you are using Windows 8 please note that our software is designed to be used in Desktop mode only We recommend using an operating system in the same language as the display language Operation in different languages is not guaranteed The specifications listed above are subject to change without notice 14 MEMO 15 E Distributor www tandd com e Colors in the photos in this catalog may be different from real product colors The specification and designs of the products in this catalog are true as of Sep 2013 Specifications are subject to change without notice Micros
2. and Infrared USB Data Loggers TR 7UI Series F i a AREO Dena Loggers Built for Cloud Storage h T amp D Cloud Service Free of Charge Automatic Data Upload via Wireless LAN With a wireless LAN the TR 71wf 72wf can automatically upload recorded data to T amp D WebStorage Service at the set interval T amp D WebStorage Service is a cloud service provided by T amp D free of charge It enables the viewing of uploaded data on your PC or mobile device anytime anywhere Seamless DY hts WAYerer t gt 4 Direct Wireless Communication with Mobile Devices Automatic Data Upload T amp D s new application ThermoWEB enables the use of mobile devices for making changing device settings downloading recorded data from the TR 71wf 72wf and viewing graph on the screen ThermoWEB is available for download free of charge DD hi Wireless LAN ce Data Upload Access D Pog J eme eren n E USB Connection to a PC TR 71wf development USB operation is also possible by connecting the TR 71wf 72wf to your computer with the USB cable e Temperature Data An alysi S sold separately o using Graph Tools Hiie Wiii S One and a Half Years of Operation with just Two Batteries Ene pri x f ai thy f W 4 Battery powered operation means the device can be placed anywhere without the need for AC power Depending on the settings the TR 71wf 72wf can be used continuously for up to
3. at 5 000 ppm or less 3 Measurement Resolution Minimum of 1 ppm Response Time 90 Approx 1 min Responsiveness Logging Capacity 8 000 data sets One data set consists of readings for all channels in that type of unit Recording Interval Select from 15 choices 1 2 5 10 15 20 30 sec or 1 2 5 10 15 20 30 60 min Recording Mode Endless Overwrite oldest data when capacity is full or One Time Stop recording when capacity is full LCD Display Items Measurements Battery Level etc Measurements CO2 concentration Temperature or Humidity fixed or alternating display Communication Interfaces USB Communication Serial Communication RS 232C 4 Infrared Communication IrPHY 1 2 low power 5 External Alarm Terminal 6 Output Terminal Open Drain Output Voltage when OFF DC less than 30V Current when ON less than 0 1A Resistance when ON about 15Q Power AC Adaptor AD 0638 or AD 0638 C AA Alkaline Battery LRG x 4 Battery Life Approx 2 days batteries only without AC adaptor 7 Dimensions H 96 mm x W 66 mm x D 46 mm excluding protrusions and sensor Weight 214 g including batteries excluding sensor Operating Environment Temperature 0 to 45 C Humidity 90 RH or less no condensation AA Alkaline Battery LR6 x 4 AC Adaptor AD 0638 or AD 0638 C USB Communication Cable US 15C Ac
4. 72wf Measurement Range Temperature 0 to 55 C Humidity 10 to 95 RH Temperature Humidity Sensor THA 3001 Included High Precision Type ji KA op N TR 72wf H Measurement Range Temperature 30 to 80 C Humidity 0 to 99 RH High Precision Temperature Humidity Sensor HHA 3151 Included Temp Humidity Barometric Pressure TR 7Ui Series Line Up llluminance UV Intensity Temperature Humidity Measurement Range Temperature 10 to 60 C Internal Sensor 0 to 50 C Supplied Sensor 40 to 110 C Optional Sensor Humidity 10 to 95 RH Supplied Sensor Barometric Pressure 750 to 1100 hPa Internal Sensor Temperature Humidity Sensor TR 3100 Included CO2 Temperature Humidity Fa Zs of l E F i Ix TR 74Ui Measurement Range Illuminance 0 Ix to 130 klx UV Intensity 0 to 30 mW cm Temperature 0 to 50 C Humidity 10 to 95 RH Display Range of Cumulative Measurement Illuminance O Ixh to 90 MIxh UV Intensity 0 mW to 62 W cm h Temperature Humidity Sensor THA 3151 and Illuminance UV Sensor ISA 3151 Included TR 74Ui H Measurement Range Illuminance 0 Ix to 130 klx UV Intensity 0 to 30 mW cm Temperature 30 to 80 C Humidity 0 to 99 RH Display Range of Cumulative Measurement Iluminance 0 Ixh to 90 MIxh UV Intensity 0 mW to 62 W cm h High Precision Temperature Humidity Sensor HHA 3151 and
5. SUS316 Only stainless section is water israel 30 kl 23 f m TR 1C30 i uminance 0 Ix to x oe UV Intensity 0 to 30 mW cm Temperature Durability 3000 TR 0106 19 600 TR 0206 2 __ Accuracy 1 25 to 60 C i TPE Resin Shielded Sensor s i i Screw down Sensor 66 or IIluminance 5 Ix to 12 6 y Unit mm A ee SST i o Response Time 90 f Th Response Time 90 TOO IY a a 50 RH o Unit mm Approx 190 sec in air OY O Approx 210 sec in air ai UV Intensity 5 0 1 to 30 mW cm at 25 C 50 RH Relative Spectral Response Compatible Sensors TR 0306 40 600 TR 0406 i Pa Illuminance Approximated to the CIE standard response function V A Temperature Humidity Sensors THA 3001 THA 3151 HHA 3151 1 l EN Itane 200 10 200 nnn Over UVB llluminance UV Sensor ISA 3151 1 Stainless Protection Sensor Stainless Protection Sensor Operating Environment 2 j 6 Temperature Sensors TR 1106 TR 1220 TR 1320 TR 0106 TR 0206 TR 0306 TR Response Time 90 5 5 S San anal Response Time 90 ea a Temperature 10 to 60 C 0406 TR 0506 TR 0706 2 Approx 11 sec in agitated water Approx 15 sec in agitated water Humidity 90 RH or less no condensation Materials Polycarbonate Glass Vinyl Coated Electrical Wire 1 Possible to use up to three cables per sensor TR 0506 7 293 600
6. Type 2 5 RH at 25 C 10 to 85 RH 4 0 RH at 25 C 0 to 10 or 85 to 99 Avg 0 3 C 20 to 80 C 5 RH 0 3 C 0 to 50 C RH Accuracy Avg 0 5 C 40 to 20 C 80 to 0 5 C at 25 C 50 RH 0 5 C all other At temperatures other than 25 C and 0 110 C temperatures C add 0 1 RH per degree of difference from 25 Humidity Hysteresis 1 5 RH or lower 2 Measurement Resolution C 01C 1 RH O G 0 1 RH Responsiveness Thermal Time Constant Approx 75 sec Response Time 90 Approx 190 sec Response Time 90 azi l ONA Response Time 90 Approx 7 min Approx 7 min Response Time 90 Approx 20 sec LCD Display Items Logging Capacity Measurements fixed or alternating display Battery Warning Mark etc 8 000 data sets One data set consists of readings for all channels in that type of unit Recording Interval Select from 15 choices 1 2 5 10 15 20 30 sec or 1 2 5 10 15 20 30 60 min Recording Mode Endless Overwrite oldest data when capacity is full One Time Stop recording when capacity is full Auto upload Interval Select from 15 choices OFF No auto upload 1 2 5 10 15 20 30 min or 1 2 3 4 6 12 24 hrs Communication Interfaces Wireless LAN Communication Standard IEEE 802 11b Security 3 WEP 64 bit 128 bit WPA PSK TKIP WPA2 PSK AES WPS 2 0 Pus
7. amp D WebStorage Service e Viewing data anywhere on mobile devices and PCs e Sending alert notifications via email from T amp D WebStorage Service Transmit Recorded Data to PC via USB Connection r j Data Analysis Easy USB connection for one device or for as many devices as your PC has ports for makes it p k _ see i easy to gather current readings from the connected device s to your computer and view those Simultaneous Multi SA See using Graph Tools readings in the computer display Channel Measurement i Data Loggers for a Variety of Measurements i The TR 7Ui series data loggers are designed to simultaneously measure and record a variety with One Device of measurements In addition to temperature and humidity TR 73U can record barometric pressure TR 74Ui models take care of Illuminance and UV intensity and TR 76Ui models log CO2 concentration WH al Get Temperature and Humidity in a Wider Range with Greater Accuracy L m FY i i K i H type models model names which include H come with our high precision temperature humidity sensor Features include a humidity measurement accuracy of 2 5 as well as the wide range measurement of temperature from 30 to 80 C and humidity from 0 to 99 RH Start Recording B i a One data set consists of readings for all channels in that type of unit If set at a recording interval of jolo p USB connection 60 minutes it gives the user one year s worth of meas
8. units of TR 71Ui 72Ui 77Ui 10 units of TR 73U 76Ui Storage Capacity 7 units of TR 74Ui 16 units of TR 51i 52i 15 units of TR 55i When downloading from units of any type containing small amounts of data it can store and manage up to 250 download sessions Communication lt Between TR 57DCi Data Logger s gt Infrared Communication IrPHY 1 2 low power TR 7Ui Series TR 5i Series 1 Serial Communication RS 232C TR 7Ui 7U 7S Series VR 71 2 Optical Communication proprietary protocol mtaranas TR 5i 5S 5 Series RTR 5 Series lt Between TR 57DCi PC gt USB Communication Serial Communication RS 232C 3 AAA Alkaline Battery LRO3 x 2 Power AAA Ni MH batteries AC adaptor AD 0638 or USB bus power may also be used Battery Life About 100 days at 1 hour of daily use 4 Dimensions H 125 mm x W 58 mm x D 25 8 mm excluding protrusions Weight Approx 110 g including batteries Operating Environment Temperature 0 to 50 C Humidity 90 RH or less no condensation Accessories AAA Alkaline Battery LROS x 2 USB Communication Cable US 15C Serial Communication Cable TR 6C10 Software CD ROM User s Manual Set Warranty Included Microsoft Windows 8 32 64 bit 6 Software Compatible OS Microsoft Windows 7 32 64 bit 65 Microsoft Windows Vista 32 bit SP1 or later Microsoft Windows XP 32 bit SP3 or later
9. 1 5 years before its batteries need to be replaced Get Temperature and Humidity in a Wider Range with Greater Accuracy The TR 72wf H comes with a high precision temperature humidity sensor Features include a humidity measurement accuracy of 2 5 as well as the wide range measurement of temperature from 30 to 80 C and humidity from 0 to 99 RH Large Logging Capacity 8000 Data Sets 2OED OT G byes FT TR 72wf 72wf H e Temperature Humidity E E E E E E E E E E E E E E E E E E E OE EE EE EE E Es En Ee u O n e a a O a O O O O O O O O O O O O E N sf One data set consists of readings for all channels in that type of unit If set at a recording interval of 60 minutes it gives the user one year s worth of measurements Easy Operation via Front Buttons It is possible to start and stop recording change recording interval and make the auto upload setting by using buttons on the device Graph Display and Monitoring on Data Analysis on PC using T amp D Graph Mobile Devices using ThermoWEB Application Examples For managing temperature and humidity in hospitals museums and temperature controlled warehouses Performance testing of humidity and heat control in housing For managing temperature and humidity in server rooms Recording temperature and humidity in subways and train cars Wireless LAN Operation enables e Automatic data upload to T
10. Cable US 15C Software CD ROM User s Manual Set Warranty Included Software Compatible OS 4 Microsoft Windows 8 32 64 bit 5 Microsoft Windows 7 32 64 bit Microsoft Windows Vista 32 bit SP1 or later Microsoft Windows XP 32 bit SP3 or later Display Languages 6 English It is also possible to measure temperature with the internal sensor However the measurement range is restricted to the operating environment for the whole device 2 Customers wishing to write their own software please contact your local distributor for the serial communications protocol specifications Note Optional serial communication cable TR 07C is also required 3 Battery life varies depending upon the ambient temperature in which it is used the recording interval the frequency of communication and the battery performance All estimates are based on operations carried out with a new battery and are in no way a guarantee of actual battery life 4 For installation it is necessary to have Administrator Computer Administrator rights 5 If you are using Windows 8 please note that our software is designed to be used in Desktop mode only 6 We recommend using an operating system in the same language as the display language Operation in different languages is not guaranteed The specifications listed above are subject to change without notice 11 Specifications TR 74Ui TR 74Ui H Temperature H
11. Illuminance UV Sensor ISA 3151 Included Data Collector TR 76Ui Measurement Range CO2 0 to 9 999 ppm Temperature 0 to 50 C Humidity 10 to 95 RH Temperature Humidity Sensor THA 3001 Included TR 76Ui H Measurement Range CO2 0 to 9 999 ppm Temperature 30 to 80 C Humidity 0 to 99 RH High Precision Temperature Humidity Sensor HHA 3151 Included i ltl LE on Infrared Communication Type Compatible Devices Infrared Communication TR 74Ui 76Ui Including H Type Cable Communication TR 73U 74Ui 76Ui Including H Type Storage Capacity Up to 256 000 readings When downloading units at full logging capacity 10 units of TR 73U TR 76Ui 7 units of TR 74Ui e When downloading units at non full logging Capacity it can store and manage up to 250 downloading sessions e Not compatible with TR 7wf series loggers Options Options Temperature Sensors for TR 71wf 73U Iluminance UV Sensor for TR 74Ui Sensor Extension Cable Measurement Range 40 to 110 C Sensor Temperature Durability 50 to 115 C Materials Vinyl Coated Electrical Wire E 65 1500 Accuracy Avg 0 3 C 20 to 80 C Avg 0 5 C 40 to 20 C 80 to 110 C ISA 3151 r T Materials Thermistor TPE resin shielded sensor 3 TPE resin shielded wire M3Screw Hole Compaction Tube Stainless Pipe SUS304 Stainless Pipe
12. Spectral Response Illuminance Approximated to the CIE standard response function V A UV Intensity 260 to 400 nm UVA UVB Measurement Resolution Iluminance Minimum of 0 01 Ix UV Intensity Minimum of 0 001 mW cm Response Time 90 3 sec at recording interval of 1 sec 6 sec at other intervals Logging Capacity 8 000 data sets One data set consists of readings for all channels in that type of unit Recording Interval Select from 15 choices 1 2 5 10 15 20 30 sec or 1 2 5 10 15 20 30 60 min Recording Mode Endless Overwrite oldest data when capacity is full or One Time Stop recording when capacity is full LCD Display Items Measurements Battery Life Warning etc Measurements IIluminance UV Intensity Temperature Humidity Cumulative IIluminance Cumulative amount of UV Light Display Pattern Alternating or Fixed display Display Digits Up to 4 digits Communication Interfaces USB Communication Serial Communication RS 232C 3 Infrared Communication IrPHY 1 2 low power Power AA Alkaline Battery LR6 x 1 Battery Life 4 Approx 6 months Dimensions H 55 mm x W 78 mm x D 18 mm Weight Approx 62 g including battery excluding sensor Operating Environment Temperature 10 to 60 C Humidity 90 RH or less no condensation Accessories AA alkaline battery LR6 USB Communica
13. TR 0706 li oi a 1 Compared to the value measured by the T amp D standard sensor for calibration under our 2 Only one cable per sensor Using an extension cable with the TR 73U may lead to measurement Stainless Protection Sensor Il i Stainless Protection Sensor sa i T calibration light source errors of 0 3 C at room temperature and 0 5 C at 50 C Response Time 90 6 S a Response Time 90 j a i a 2 Do not expose to condensation dampness corrosive gases or organic solvents Approx 10 sec in agitated water D Approx 11 sec in agitated water f TR 5C10 Temperature Durability 1000 Temperature Sensors for TR 71wf Fluoropolymer Coated Type 25 to 60 C rT Data Collector for TR 73U 74Ui 76Ui C tible S i j Measurement Range 60 to 155 C Sensor Temperature Durability 70 to 180 C a Ap i aia Sensor Accuracy Avg 0 5 C 40 to 80 C Avg 1 0 C 60 to 40 C 80 to 100 C J Avg 2 0 C 100 to 155 C TR 57DCi TR 3100 3 Unit mm Materials Thermistor Stainless Pipe SUS316 Fluoropolymer Coated Compaction Tube Fluoropolymer Coated Electrical Wire Accessories Software CD ROM 3 Only one cable per sensor TR 1106 R TR 1220 USB Communication cable US 15C Fluoropolymer Coated Sensor T f Stainle
14. anic solvents or insecticides for High Precision Temperature Humidity Sensors 2 When used in environments where temperature and humidity are over the values of 50 C75 60 C 50 70 C 35 and 80 C 25 sensor hysteresis may fluctuate by values greater than 1 5 RH Under certain circumstances it may take some time to return to normal measurement capability Temperature Humidity Sensors for TR 73U Measurement Range Temperature 0 to 50 C Humidity 10 to 95 RH Accuracy Temperature Avg 0 3 C 0 to 50 C Humidity 5 RH at 25 C and 50 RH Materials Temperature Humidity Sensor Polypropylene Resin Vinyl Coated Electrical Wire TR 3100 TR 3110 Response Time 90 i Response Time 90 s15 1500 About 7 min About 7 min Unit mm Unit mm Specifications TR 71wf TR 72wf TR 72wf H TR 0106 THA 3001 HHA 3151 Sensor External 1 aa gaa calc ease ea ee ack Graal Weeds a aaa ig a an eee Uy aS Ry Cc a Ue ages ia a al ge a Aa aa aa a Thermistor Thermistor Polymer Resistance Platinum Resistance Electrostatic Capacitance Measurement Channels Temperature 2ch Temperature 1ch Humidity 1ch Temperature 1ch Humidity 1ch Measurement Units G F G F RH G F RH 40 to 110 C Supplied Sensor Measurement Range 60 to 155 C Optional Sensor Oto 55 C 10 to 95 RH 30 to 80 C 0 to 99 RH Fluoropolymer Coated
15. cessories Temperature Humidity Sensor THA 3001 or HHA 3151 Software CD ROM User s Manual Set Warranty Included Software Compatible OS 8 Microsoft Windows 8 32 64 bit 9 Microsoft Windows 7 32 64 bit Microsoft Windows Vista 32 bit SP1 or later Microsoft Windows XP 32 bit SP1 or later Display Languages 10 English 1 Make sure to use the data logger within the operating environment as listed in the specifications 2 When used in environments where temperature and humidity are over the values of 50 C 75 60 C 50 70 C 35 and 80 C 25 sensor hysteresis may fluctuate by values greater than 1 5 RH Under certain circumstances it may take some time to return to normal measurement capability 3 Stated value is the measurement accuracy of the CO2 sensor when Auto Calibration is operating properly A change in atmospheric pressure directly influences the reading of CO2 which can cause measurement errors a decrease in pressure by 10hPa results in a relative decrease in CO2 by 1 6 In such a case we recommend carrying out the Atmospheric Pressure Correction function found in CO2 Recorder for Windows 4 Customers wishing to write their own software please contact your local distributor for the serial communications protocol specifications Note Optional serial communication cable TR 07C is also required 5 If you wish to use infrared communication to download recorded data it is neces
16. el Spe talized Connector D sub Humidity 10 to 95 RH no condensation 18 6 WE Humidity 10 to 95 RH no Soin 1500 Accuracy condensation AT 76K1 For communication between Temperature 0 5 C Accuracy tof ennem he PC and TR 73U 74Ui Humidity 5 RH at 25 C and 50 RH ey Temperature 0 5 C al Accessories Aa Sa Response Time 90 Approx 7 min Humidity 5 RH at 25 C and Lock Screw x 2 i Unit mm PO ANN C DA a luding H T TE _ Response Time 90 Approx 7 min ompatible Unit TR 76Ui Including H Type HHA 3151 High Precision Type Maea Alimini Measurement Range 1 Temperature 30 to 80 C Humidity 0 to 99 RH Software Set for TR 71wf 72wf 72wf H Accuracy Temperature SO 15C1 0 3 C 0 to 50 C Contents 0 5 C at all other temperatures 10 Faas tunit mm Software CD ROM Humidity USB Communication cable US 15C 2 5 RH at 25 C 10 to 85 RH 4 RH at 25 C 0 to 10 RH or 85 to 99 RH At temperatures other than 25 C and 0 C add 0 1 RH per degree of difference from 25 Humidity Hysteresis 1 5 RH or lower 2 Response Time 90 Temperature Approx 7 min Humidity Approx 20 sec Long Term Stability 1 RH yr 0 1 C yr under normal operational conditions 1 1 Do not expose to condensation dampness corrosive gases or org
17. g environment for the whole device 2 When used in environments where temperature and humidity are over the values of 50 C 75 60 C 50 70 C 35 and 80 C 25 sensor hysteresis may fluctuate by values greater than 1 5 RH Under certain circumstances it may take some time to return to normal measurement capability 3 The WPS feature is not available when WEP 64bit 128bit or WPA PSK TKIP is selected in Access Point Settings If you wish to use the WPS feature please select WPA2 PSK AES or disable wireless security 4 Optional USB Mini B Cable US 15C is required for USB communication 5 Battery life varies depending upon the frequency of communication wireless LAN environment ambient temperature recording interval and battery performance All estimates are based on operations carried out with a new battery and are in no way a guarantee of actual battery life 6 For installation it is necessary to have Administrator Computer Administrator rights 7 If you are using Windows 8 please note that our software is designed to be used in Desktop mode only 8 We recommend using an operating system in the same language as the display language Operation in different languages is not guaranteed The specifications listed above are subject to change without notice 10 TR 3100 External 1 Specifications senson a a ik Barometric Pressure Sensor Internal Thermistor Polymer Resistance Measure
18. h Button Configuration Protocol HTTP DHCP DNS USB Communication 4 USB 2 0 Mini B connector Power AA Alkaline Battery x 2 AA Ni MH batteries may also be used USB Bus Power 5V 200mA Battery Life 5 With wireless LAN communication Approx 10 days to 1 5 years Ex Approx 10 days when Auto upload Interval is 1 min 1 yr when 1 hr 1 5 yrs when 12 hrs or more Without wireless LAN communication Approx 1 5 years Dimensions H 58 mm x W 78 mm x D 26 mm Weight Approx 100 g including batteries Operating Environment Temperature 10 to 60 C Humidity 90 RH or less no condensation Accessories Software Compatible OS 6 Temperature Sensor TR 0106 x 2 Temperature Humidity Sensor THA 3001 x 1 High Precision Temperature Humidity Sensor HHA 3151 x 1 AA Alkaline Battery LR6 x 2 Registration Code Label Manual Set Warranty Included TR 7wf for Windows For PC Microsoft Windows 8 32 64 bit 7 Microsoft Windows 7 32 64 bit Microsoft Windows Vista 32 bit SP1 or later Microsoft Windows XP 32 bit SP3 or later ThermoWEB For Mobile Devices Android 2 2 or later May not work on all devices iOS 5 0 or later iOS App will be released in Dec 2013 Display Languages 8 English 1 With the TR 71wf it is also possible to measure temperature with the internal sensor However the measurement range is restricted to the operatin
19. ment Channels Temperature 2ch Humidity 1ch Barometric Pressure 1ch Measurement Units C F RH hPa Measurement Range 0 to 50 C Supplied Sensor 0 40 to 110 C Optional Sensor 10 to 95 RH 750 to 1100 hPa Accuracy Avg 0 3 C 0 to 50 C 5 RH at 25 C 50 RH 1 5 hPa Measurement Resolution 0 1 C 1 RH 0 hea Responsiveness Response Time 90 Approx 7 min 4 seconds or 40 seconds if recording interval is 10 sec or more Logging Capacity 8 000 data sets One data set consists of readings for all channels in that type of unit Recording Interval Select from 15 choices 1 2 5 10 15 20 30 sec or 1 2 5 10 15 20 30 60 min Recording Mode Endless Overwrite oldest data when capacity is full One Time Recording automatically stops when capacity is full LCD Display Items Measurements fixed or alternating display Battery Warning Mark etc Communication Interfaces USB Communication Serial Communication RS 232C 2 Power AA Alkaline Battery LR6 x 1 Battery Life 3 Approx 10 months Dimensions H 55 mm x W 78 mm x D 18 mm Weight Approx 62 g including batteries Operating Environment Temperature 10 to 60 C Humidity 90 RH or less no condensation Accessories Temperature Humidity Sensor TR 3100 x 1 AA alkaline battery LR6 USB Communication
20. oft and Windows are registered trademarks of Microsoft Corporation USA and other countries e Google Android and Google Play are trademarks or registeredtrademarks of Google Inc e Apple and App Store are trademarks or registered trademarks of Apple Inc in the U S and other countries e Company names and product names are trademarks or registered trademarks of each company Caution regarding safety For safe operation carefully read instructions before using the product T amp D Corporation 817 1 Shimadachi Matsumoto Nagano 390 0852 Japan Please send your inquiries to E mail sales tandd com Facsimile 81 263 40 3152 gt PRINTED WITH gZ SOYINK Trademark of American Soybean Association 2013 09 16304930004F 1st Edition A LD
21. or installation it is necessary to have Administrator Computer Administrator rights 6 If you are using Windows 8 please note that our software is designed to be used in Desktop mode only 7 We recommend using an operating system in the same language as the display language Operation in different languages is not guaranteed The specifications listed above are subject to change without notice 12 Specifications TR 76Ui TR 76Ui H TemperatreMumity Sensor A a xiama Thermistor Polymer Resistance Platinum Resistance Electrostatic Capacitance Measurement Channels Temperature 1ch Humidity 1ch Temperature 1ch Humidity 1ch Measurement Units C F RH C F RH Measurement Range 1 O to 55 C 10 to 95 RH 30 to 80 C 0 to 99 RH 2 5 RH at 25 C 10 to 85 RH F o 4 0 RH at 25 C 0 to 10 or 85 to 99 RH Accuracy 0 5 C F pine 50 RH ee one ae eratures At temperatures other than 25 C and 0 C add i i a p 0 1 RH per degree of difference from 25 Humidity Hysteresis 1 5 RH or lower 2 Measurement Resolution 0 1 C OG Responsiveness Response Time 90 Approx 7 min Response Time 90 AE Response Time 90 Approx 7 min Approx 20 sec CO2 Sensor Internal NDIR Measurement Channels CO2 Concentration 1ch Measurement Units ppm Measurement Range 0 to 9 999 ppm Accuracy 50 ppm 5 of reading
22. sary to purchase the Data Collector TR 57DCi sold separately 6 In order to use the external alarm terminal please prepare a compatible connector JST PAP 04V S 7 Battery life varies depending upon the ambient temperature in which it is used the recording interval the frequency of communication and the battery performance All estimates are based on operations carried out with a new battery and are in no way a guarantee of actual battery life Battery life may be shortened if the unit is used under inverter type fluorescent lighting 8 For installation it is necessary to have Administrator Computer Administrator rights 9 If you are using Windows 8 please note that our software is designed to be used in Desktop mode only 10 We recommend using an operating system in the same language as the display language Operation in different languages is not guaranteed The specifications listed above are subject to change without notice 13 Specifications Data Collector TR 57DCi TR 7Ui Series TR 71Ui 72Ui 74Ui 76Ui 77Ui TR 7U Series TR 71U 72U 73U TR 7S Series TR 71S 72S TR 5i Series TR 51i 52i 55i TC 55i Pt 55i V 55i mA 55i P Compatible Devices TR 5S Series TR 51S 52S TR 5 Series TR 51A 52 RTR 5 Series RTR 51 51A 52 52A 52Pt 53 53A RVR 52A including L types Others VR 71 Up to 256 000 readings When downloading from units filled to logging capacity 16
23. ss Protection Sensor 185 30 2000 AAA Alkaline Battery x2 T Response Time 90 2 2 w Response Time 90 TT Serial Communication Cable TR 6C10 Communication Cable Approx 80 sec in air I Approx 150 sec in air 3 a a a w et Approx 7 sec in agitated water Approx 7 sec in agitated water US 15C USB Communication Cable Unit mm 1500 TR 1320 70 30 2000 j Stainless Protection Sensor T 7 Wall Attachment ecm Sec j 2 E Response Time 90 T eit TR 07K2 Approx 90 sec in air D 5 Approx 3 sec in agitated water inikman Accessories o TR 6C10 Serial Communication Cable Lock Screw x2 a Double sided adhesive tape For communication between 1000 Temperature Humidity Sensors for TR 72wf 74Ui 76Ui Compatible Unit Toe rend Th aN TR 71wf 72wf 73U 74Ui Including H Type 76Ui _S i Materials Temp Humidity Sensor Polypropylene Resin Polycarbonate Vinyl Chloride Coated Electrical Wire Materials Polycarbonate THA 3001 THA 3151 a seated POE e a TR 07C Serial Communication Cable Measurement Range Ch 51 5 Measurement Range 1 l E oa may occur If polycarbonate IS exposed to strong Impact at temperatures o or Sonar Type Temperature 0 to 55 C TTT Temperature 0 to 55 C
24. tion Cable US 15C Illuminance UV Sensor ISA 3151 Temperature Humidity Sensor THA 3151 or HHA 3151 Software CD ROM User s Manual Set Warranty Included Software Compatible OS 5 Microsoft Windows 8 32 64 bit 6 Microsoft Windows 7 32 64 bit Microsoft Windows Vista 32 bit SP1 or later Microsoft Windows XP 32 bit SP3 or later Display Languages 7 English 1 When used in environments where temperature and humidity are over the values of 50 C 75 60 C 50 70 C 35 and 80 C 25 sensor hysteresis may fluctuate by values greater than 1 5 RH Under certain circumstances it may take some time to return to normal measurement capability 2 Compared to the value measured by the T amp D standard sensor for calibration under our calibration light source 3 Customers wishing to write their own software please contact your local distributor for the serial communications protocol specifications Note Optional serial communication cable TR 07C is also required 4 Battery life varies depending upon the ambient temperature in which it is used the recording interval the frequency of communication and the battery performance All estimates are based on operations carried out with a new battery and are in no way a guarantee of actual battery life When infrared communication function is enabled battery life may be shortened if the unit is used under the inverter type fluorescent lighting 5 F
25. umidity Sensor ie E echoren acti adgeanesmten t ete sane Nee O ON EM e an External Thermistor Polymer Resistance Platinum Resistance Electrostatic Capacitance Measurement Channels Temperature 1ch Humidity 1ch Temperature 1ch Humidity 1ch Measurement Units C F RH C F RH Measurement Range 01055 G 10 to 95 RH 30 to 80 C 0 to 99 RH 2 5 RH at 25 C 10 to 85 RH Accuracy 0 5 C a AAR HU ee E P Se E E A ae re tte at 25 C 50 RH 0 5 C all other temperatures 0 1 RH per degree of difference from 25 Humidity Hysteresis 1 5 RH or lower 1 Measurement Resolution 0 1 C 0i C Responsiveness Response Time 90 O i 1 Response Time 90 Approx 7 min Approx 7 min Response Time 90 Approx 20 sec IIluminance UV Sensor External ISA 3151 Measurement Channels IIluminance 1ch UV intensity 1ch Measurement Units Illuminance Ix klx UV Intensity mW cm Measurement Range luminance O Ix to 130 klx UV Intensity 0 to 30 mW cm Units of Cumulative Measure ment Cumulative IIluminance Ixh kIxh MIxh Cumulative amount of UV Light mW cm h W cm h Display Range of Cumulative Measurement Illuminance 0 Ixh to 90 MIxh UV Intensity 0 mW to 62 W cm h Accuracy Illuminance 10 Ix to 100 klx 5 at 25 C 50 RH UV Intensity 0 1 to 30 mW cm 5 at 25 C 50 RH 2 Relative
26. urements Application Examples e For managing temperature and humidity in hospitals museums and temperature controlled warehouses e Managing CO2 temperature and humidity in schools from kindergartens to universities e For research studies on photosynthesis and growth of plants e Measuring the degree of air tightness in packaging during transportation e For management of illuminosity and UV light to prevent deterioration of exhibits in art F mun TR 73U e Barometric Pressure e Temperature Humidity USB Connection Download Recorded Data Change Settings museums and other exhibit forums i Z TR 74Ui 74Ui H e lluminance UV Intensity Graph Display e Temperature Humidity on a Data Collector i Infrared Hof cid teal Communication T TRr4Ui cH2iL 12 TSAI CHS 1243 PEER EEERPERRPREREREREREREEEe a1 6 E E CH fcr niert Fan 04 10 Cosbessn bars i laest ce Serial I zi 4 C Communication TR 76Ui 76Ui H e Canaan e CO2 Temperature Jh E 5 TAA e Humidity Graph View Simple startup upon connection to PC e Monitor multiple channels of data in trend graph TR 7wf Series Line Up Temperature 2ch TR 71wf Measurement Range Temperature 40 to 110 C Supplied Sensor 60 to 110 C Optional Sensor Fluoropolymer Coated Type Temperature Sensors TR 0106 x 2 Included Temperature Humidity I TR