USING THE OCEAN OPTICS SPECTRORADIOMETER By Mark
Contents
1. Dell Latitude this means scrolling the screen Start CDAP Make sure date and time are correct Use GPS unit to enter latitude and longitude information remember west longitude is expressed as a negative number Select daylight savings time status and click the acguire data button On the next screen enter the following information by clicking the appropriate buttons a The spectrometer with an ID number ending in 21 red collects downwelling radiation and is on COM6 b The spectrometer with an ID number ending in 22 green collects upwelling radiation and is on COMS c The calibration source is a 99 white panel Click on done to continue Click the change directory button and either select or create and select a directory You must select a directory in order to collect data Enter an appropriate project name Enter something like CAL as the rep name You must enter both of these before collecting data Get out the white reference calibration panel Handle the panel using only clean gloves never touch it with unprotected hands Point the green fiber head so that its entire 25 degree field of view contains only the white reference and does not contain any shadows Hold the cosine corrector red fiber head vertical and directly overhead Click the cal scan button It should turn red this means that the next scan will be a calibration scan While both fibers are pointed properly click the Acqu
2. B2000 Miniature Fiber Optic Spectrometer 2 including o Ocean Optics GRATING 2 350 1000 nm o Ocean Optics SLIT 25 25 micron slit o Ocean Optics OFLV 350 1000 detector filter Ocean Optics CC 3 UV Cosine Corrector Ocean Optics QP400 VIS NIR fiber optics 6 various lengths Labsphere Spectralon SRT 99 100 99 reflectance standard 10 inch by 10 inch Quatech QSP 100 four port RS 232 serial PCMCIA card Serial cables 12 V battery with power adapter and splitter GPS unit any Dell Latitude notebook computer e For technical specifications of these components visit the manufacturers websites o Www oceanoptics com www labsphere com O o www quatech com o www calmit unl edu BEFORE GOING IN THE FIELD Check the hardware list above to make sure everything is present items should be in the dark gray pelican case except fiber optics cosine corrector and laptop Make sure the fiber optics that you will use are not broken To do this remove the caps from both ends hold one end towards light and look through the other end You will see light shining through if the fiber is in good condition Make sure the Quatech QSP 100 card is in the laptop and its batteries are fully charged The Quatech drivers must be installed CDAP must be installed on the laptop and the current ini file must reflect the instrument calibrations if you are using a different laptop copy this file from the Dell Latitude Check GPS batteries and the 12 V batte
3. USING THE OCEAN OPTICS SPECTRORADIOMETER By Mark Nordheim Last revised August 6 2004 WHAT IS THIS There are two different spectroradiometer systems at ERSC This document concerns the dual Ocean Optics USB2000 system The ASD FieldSpec Hand Held instrument is the subject of a separate document The USB2000 system consists of two spectrometers connected together One measures incoming sunlight and the other measures upwelling light from the target A white reference panel is also used to calibrate reflectance measurements This configuration was originally developed at the University of Nebraska Lincoln s Center for Advanced Land Management Information Technologies UNL CALMIT The spectrometers are operated using a laptop which must be brought out in the field running CDAP CALMIT Data Acquisition Program Questions about the hardware or software can be directed to Bryan Leavitt at CALMIT bleavitt calmit unl edu phone 402 472 0306 The primary advantage of the Ocean Optics system is the simultaneous collection of upwelling and incoming radiation This compensates for changes in lighting conditions between calibration and data collection Another advantage is that the fiber optics can be placed underwater or in other unusual conditions The main disadvantage is the complexity the system requires two people to operate effectively and may be impractical under certain field conditions HARDWARE LIST e Ocean Optics US
4. ire button It should turn red while the system is scanning Hold both fibers in place until the buttons turn gray and a scan successfully completed message appears on the status bar Repeat the calibration scan several times You will have to click both cal scan and begin scan each time There should be at least six calibration scans per project though they need not all be done at the beginning Change the rep name to the name of the target for easy identification later Continue to hold the red fiber overhead and vertical Aim the green fiber at the target Click begin scan to collect a reflectance spectrum Hold fibers in place until the scan is complete At least six reflectance spectra should be collected per target Use the graphs at the top of the screen to make sure that data make sense Click Exit when finished Pe POST PROCESSING Start CDAP and click a daylight savings setting Then click on process data Click on current ini select 99 Panel and OK Find and select the directory to process and accept all of the default settings The most important output file will be called reflectance txt and can be opened with Excel
5. ry ASSEMBLY Items marked with red tape are associated with incoming solar radiation downwelling Items marked with green tape are associated with upwelling radiation from the target In general connect red to red and green to green Here are some steps to follow 1 Attach the power adapter to the 12 V battery red to red black to black 2 Connect the plugs on the other side of the adapter to the appropriate holes in the USB2000 units Attach the serial cables to the USB2000 units serial ports red to red green to green The multiport adapter connects to the QSP 100 card and to the serial cables The red fiber optic plugs into the red spectrometer and has the cosine corrector on the other end The green fiber plugs into the green spectrometer and has a bear head at the other end Remove the cap The USB ports on the spectrometers are not used Serial Ports Fiber Optic Power Plugs Ports OPERATION Note that this is not intended to be a complete user s manual for CDAP As far as I know no such manual exists These steps are essential for collecting data with the Ocean Optics system 1 10 11 12 13 Double check the all connections described above are tight then turn on the laptop Select one person to handle the computer and the red fiber The other person will handle the calibration panel and the green fiber In order to use CDAP the screen resolution must be set to 1024 x 768 or higher On the