Home

Installation Guide

image

Contents

1. Function Configuration Parameter Configuration Part1 Parameter Configuration Part2 Time Configuration AS410_Out2 Door 1 v Event Alam YV Output Type Output Function AS410_Out3 Door 2 Electric Lock V AS410_Out4 Door 2 Vv Event Alarm YV For details on configuring the input and output devices see the nout Configuration and Output Configuration section in Chapter 8 of the GV AS Controller User s Manual June 3 2015 L GeoUision Specifications Voltage DC 12V 24V Current 500mA at 12V 250mA at 24V Holding Force 544 311 kg 1200 Ib Operating Temperature 20 C 60 C 4 F 140 F Dimensions L x W x H 266 x 73 x 40 mm 10 47 x 2 87 x 1 57 Armature Plate Dimensions L x W x H 185 x 61 x 16 mm 7 28 x 2 40 x 0 62 Weight 5 kg 11 02 Ib Certification CE UL ISO 9001 ROHS All specifications are subject to change without notice 10 June 3 2015
2. to use wire No 26 AWG American Wire Gauge or above 8 June 3 2015 C GeoVision Setting the Web Interface of the GV AS Controller Here we use GV AS410 Controller as an example 1 To configure the input setting of connected sensor on the Web interface of the GV AS410 select Advanced Setting select Input Configuration and set the input function to Door Contact GeoVision Basic Setting Network Configuration Other Configuration Firmware Update Security Configuration Advanced Setting Function Configuration Parameter Configuration Part1 Input Configuration Input Function 01 AS410_IN1 NO v Door 1 v Door Contact v Door nf Door Contact y 02 AS410_IN2 NO v Door 1 v Exit Button v 03 AS410_IN3 NO v Door 1 v Fire Sensor v I n p ut Ty pe n p ut F u n cti O n 04 AS410_IN4 NO v Door 1 v Tamper Sensor V 05 AS410_IN5 NO v Door 2 v Door Contact wv 2 To configure the output setting of the electromagnetic lock on the Web interface of the GV AS410 select Advanced Setting select Output Configuration and set the output function to Electric Lock L GeoVision Basic Setting Network Configuration Other Configuration Firmware Update Security Configuration Advanced Setting Output1 Output16 Configuration Output Function 3A 30VDC 110VAC 250VAC AS410_Out1 Door 1 v I Electric Lock Vv Electric Lock hye
3. June 3 2015 C GeoVision Connecting to Power Unscrew the cover of electromagnetic lock and connect the lock to the output interface of the GV AS Controller and a power supply Here we use GV AS410 Controller as an example GV ML1200 Electromagnetic Lock GV A 5410 NO COM OUTA COM REED SWITCH NC SENSOR NO OUTS COM Power Selector NC Jumper 12VDC 24VDC om HI OU T2 COM slal G External Power Supply 1 Power Terminal Block Connects to a DC 12V 24V power source Connect the point on the electromagnetic lock to COM on GV AS410 connect the two points of the electromagnetic lock and the external power supply together and connect the point on the external power supply to NC on GV AS410 2 Power Switch Jumper Plug the power jumpers to Pins A C and Pins B D for a 12V DC power source Plug the power jumper to Pins C D for a 24V DC power source June 3 2015 5 L GeoUision Note 1 It is required to connect an external power supply if the total power consumption of the output devices and readers connected to the GV AS Controller exceeds 3A for GV AS210 2110 3 5A for GV AS410 4110 or 5A for GV AS810 8110 2 You may use the power outputs on the GV AS Controller when the total power consumption of the output devices and readers connected to the GV AS Controller is under 3A for GV AS210 2110 3 5A for GV AS410 4110 or 5A for GV AS810 8110 Here we use GV AS410 Control
4. L GeoVision GV ML1200 Electromagnetic Lock The GV ML1200 is a surface mount electromagnetic lock featured with a built in voltage spike suppressor and a sensor It can be applied for single leaf or double leaf doors Packing List 1 GV ML1200 electromagnetic lock x 1 Magnet faceplate x 1 M8 41mm screw black rubber spacer x 1 o eo nut x 1 Galvanized steel rivet x 2 S Black rubber spacer x 2 8 Aluminum shim x 2 D 10 5 8 screw x 2 10 10 1 25 screw x 9 Y ss 11 M4 7mm flat head screw x 2 12 M5 8mm flat head screw x 2 amp Py 13 Washer x 3 14 Aluminum tube x 1 15 Tamper proof tube x 3 gt June 3 2015 1 C GeoVision Installation Before installing add the thread lockers to all screws Be sure to firmly tighten the screws 1 Install the electromagnetic lock to the doorframe ___Permanent Magnet 2 June 3 2015 C GeoVision 2 Mounts the armature plate to the door Typical Installation of the electromagnetic lock Note To make the armature plate adjust its proper position to the magnet automatically do not fix the armature plate too tightly and make the rubber washer more flexible June 3 2015 3 L GeoUision Note If the power switch is not wired between the DC source voltage and the magnet it will take longer to de energize the magnet simulating residual magnetism Switch or Switch or solid state Incorrect 4
5. ler as an example NO GV ML1200 OUT2 COM Electromagnetic Lock NC NO OUT1 COM NC 6 June 3 2015 C GeoVision Connecting a Sensor to the GV AS Controller There are two types of sensors for the electromagnetic lock Door Closure Detection Sensor and Magnet Clasp Detection Sensor The sensors will detect whether the door is closed tightly or not and trigger a Held Open message on GV ASManager when the door remains unlocked To connect the sensors to the GV AS Controller follow the steps below Here we use GV AS410 Controller as an example Note Only one type of sensor could be applied at a time Option 1 Door Closure Detection Sensor To connect the Door Closure Detection Sensor to the GV AS410 connect the Red wire of the sensor to the Input of the GV AS410 and connect the Black wire of the sensor to the Ground of the GV AS410 GV AS410 GV ML1200 Electromagnetic Lock June 3 2015 7 C GeoVision Option 2 Magnet Clasp Detection Sensor To connect the Magnet Clasp Detection Sensor to the GV AS410 connect one wire from NC of the electromagnetic lock s circuit board to the Input of the GV AS410 and connect the other wire from COM of the electromagnetic lock s circuit board to the Ground of the GV AS410 Circuit Board of GV ML1200 Electromagnetic Lock Note The two wires mentioned in Option 2 are not included in the package the users must prepare them additionally It is recommended