1. A G EEJ Tools Parts required for Installation Tools Ladder Tape measure Level Wire cutter 4 gauge 5 mm dia wire stripper for cable sleeve 22 gauge 0 25 mm wire stripper for single wires Flathead screwdriver 1 10 size 0 2 4 mm Electric screwdriver with phillips head size 2 Electric drill with 1 4 6 mm drill bit Parts 2 or 3 screws e g self tapping to attach aluminum rail to door panel Page 1 WH Safety Precautions A 241 General Safety Warning failure to follow these safety precautions may cause damage to sensor or objects serious personal injury or death This product is designed to be mounted on the top of a swinging revolving or folding automatic door Do not use this product other than for its specified application Observe all local national and international door safety standards codes and laws Only trained and qualified personnel may install and initialize the sensor Only authorized Bircher Reglomat personnel may perform hardware software changes or repairs to the product The unit should only be operated from a safety extra low voltage SELV system with safe electrical separation Always consider the safety functions of your applications as a whole never just in relation to one individual section of the system The installer is responsible for testing the system to ensure it meets all applicable safety standards e g ANSI 156
2. Switch 1 Operating mode selection Switch 2 Switching mode selection Up Moving mode background suppression on e g mounted on swing door panel No background necessary floor is ignored background suppression No monitoring the sensor cannot be tested in this operating mode test input TI without function Down Stationary mode background analysis e g mounted on machine A stable background is essential the floor is analyzed background evaluation Monitoring possible the sensor can be tested via the test input Up m Passive Switching a The relay opens the NO contact closes the NC on detection see section 3 4 A power failure or wire damage Is interpreted as a detection and will trigger the respective safety feature of the door Down aR Active Switching 2 The relay connects NO to COM on detection see section 3 4 Page 4 EFJ Scanning Range Adjustment First check the scanning range ncreasing the with a white letter size sheet of gt q scanning range paper or the palm of your hand lt Then adjust the scanning range UF with the thumb wheel lt Moving pattern away from N Recommended height setting is Decreasing the 10 25 25 64 cm scanning range to floor FEJ Detection Area Adjustment Adjust the detection area by sliding the sensor in the rail The red screws on mounting brackets should be partly loosen
3. Technolo Active infrared wavelength 880 nm Jy Triangulation principle IR spot dimension Approx 3 75 mm in diameter for scanning range of 80 2000 mm Detection distance Stationary mode approx 4 100 100 2500 mm measured from sensor Moving mode approx 20 100 500 2500 mm Scanning range setting Thumb wheel approx 60 100 1500 2500 mm Deviation from 68 F 20 C 140 F 60 C 10 4 F 20 C 10 Temperature dependence with reference to the set scanning range Max 20 White longer scanning range Black shorter scanning range Monitoring input labeled test input Activated with 17 30 V DC against power for stationary mode only Response time upon detection Approx 30 ms Response time with test signal Max 500 ms only possible with DC operation Black white difference with reference to scanning range set Operating voltage 17 37V DC 18 26V AC lt 110 mA Relay changeover Form C SPDT contact 48 V AC DC Current Nominal ohmic load 1A 24V DC Ind cap load provide spark quenching 0 5 A AC DC Max switching power 55VA 24W Mounting height 5 5 8 8 1 7 2 7 m Suitable for use in acc to NEMA 5 IP52 Protection class in housing with aluminum rail cover endcaps Aluminum Lens cover PC black Sensor ABS Storage temperature 40 F to 176 F 40 C to 80 C L x Wx H without housing 7 x 1 4 x 198 5 x 31 x 20 mm
4. 10 Never touch any electronic components or lenses A N EFJ installation Safety Follow all steps outlined in this manual in order for proper installation of the product Stop all pedestrian traffic through the door before installing sensor Ensure there is no pedestrian traffic through the door until sensor is installed and tested for compliance with all applicable safety standards e g ANSI 156 10 Verify proper installation of door equipment before installing sensor Shut off all power before attempting any wiring procedures Always use wire terminals to terminate stranded wire ends Check placement of wiring to ensure moving parts are not impeded by wires Make sure wiring is correct before applying power to the sensor to avoid damage to equipment Ensure e g by standing in the pattern that installation is in compliance with all applicable standards e g ANSI 156 10 after installation If the sensor sustains damage e g falls replace it with a new unit If a satisfactory solution cannot be achieved after troubleshooting a problem please call Bircher Reglomat at 800 252 1272 or visit our website at www bircherreglomat com DO NOT LEAVE ANY PROBLEMS UNRESOLVED DO NOT SACRIFICE SAFETY FOR ANY REASON Perparation EEE Opening Housing amp Removing Sensor Loosen both red mounting bracket screws e lide both mounting brackets slightly to their side and remove the sensor from the aluminu
5. Dimensions housing inc end cap W x H length variable 1 x 1 38 mm x 44 mm Weight finished TopScan Ill 36 assembly 1 Ib 8 oz 0 68 kg sensor unit only 1 59 oz 45 g Output Bircher Reglomat 870 Pratt Avenue N Schaumburg IL 60193 y Phone 847 952 3730 Lo Toll Free 800 252 1272 Fax 847 952 2005 Reg lomat Email sales bircherreglomat com Web www bircherreglomat com US03 009D 6 13
6. LACK power GREEN sensor signal RED power 9 WHITE common i GREEN sensor signal RED power BLACK power Approach side COM safety signal NO NC _ WHITE sensor signal aE BLUE re routed from 6 SAVIYA YD Y S Z z D d W CD Swing side COM safety signal NO NC Page 3 5 Completing the Assembly EXE Mounting the Sensor s in the Housing 1 Loosen the red 2 Click the mounting 3 Slide the sensor into 4 Move the brackets toward screws on the brackets into the position between the sensor and apply pressure mounting brackets aluminum rail Brackets brackets until the pins snap into the can also be clicked out if sensor Tighten screws to screws are sufficiently secure loosened Note for a denser detection pattern mount multiple sensors on one aluminum rail and connect with intra unit flat cables Insert the Intra unit flat cable connector correctly into the receptacle or damage could result EFJ Routing the Cable rar i om s Route the oe from i Lead the cable behind the ng m screw terminal away throug sensor and out the end of the lel heave a e cable loop location right or left 6 Sensor Adjustments Power on the sensor after installation is complete The LED illuminates when the sensor detects a presence XE Selecting the Operating amp Switching Modes Typical setting for swing door shown Factory settings
7. This product meets or exceeds ANSI Standard 156 10 as independently g tested by T V Rheinland North America Reglomat TopScan Active infrared door mounted safety sensor for User Manual swinging low energy revolving amp folding doors aie Introduction ERG Parts of the TopScan Assembly El i E D Shown is TopScan IlI 36 in silver with right cable exit D Actual configuration may vary A End cap screws 2x C Aluminum rail E Intra unit connector cable 2x B End caps 2x D Sensor unit 3x F 8 ft 2 4 m 6 wire cable for door operator G Lens cover EPA Parts of the Single Sensor S 1 Height distance adjustment thumb wheel P Wiring terminal block Infrared receiver lens 0 Cable exit R S Snap in mounting brackets 2x Infrared sender lens Detection indication LED red DIP switches Mounting bracket connecting pin 2x Extension connector Connector for intra unit cable 2x Left right pattern position selector oO Z S amp S rm
8. a Depending on the door opening a right or left sensing location must be selected The selector can be found on the backside of the optics To change the detection area l slide the plastic selector to position L or R Left Right Position of the detection area l L Left R Right Factory setting Electrical Connection Single TopScan Sensor Pre assembled TopScan Self Assembly 1 Remove the existing unwired terminal block by pushing fl it out from the back with a screwdriver if necessary sai 1 A 9 Q 2 Attach the pre wired terminal block to the terminal 0 C12 receptor pins on the sensor unit common S OC 3 NC O O 4 No S 5 Test input 1Q Ol 6 monitoring Monitoring available in stationary mode only Monitoring Monitoring available in stationary mode only TopScan System An additional TopScan mounted on the opposite side of the door panel can be connected through the extension connector terminals 7 12 Wire colors refer to the pre installed 6 wire cable provided with TopScan assemblies Pre installed 6 wire cable Som o Drill hole through aluminum mt rails amp door for cable feed DOOR OPERATOR Pre installed 6 wire cable 2 wiring changes to be made Pre installed 6 wire cable from other door face unm 17 30 VDC 18 28 VAC Sa Power N BROWN re routed from 4 B
9. ed for easy adjustments Ensure red mounting bracket screws are sufficiently loosened to move over aluminum rail mounting screw heads EXE Inclination Angle Adjustment Using both hands grasp both sides of the sensor and carefully tilt it up or down to change the inclination angle Scale 30 15 0 1click 3 The angle 0 to 30 can be read on the sides of the mounting brackets AN Ensure the sensor is level by setting the same angle on both brackets 4 48 120 cm 6 5 Adaptation to Meet Standard Requirements To comply with ANSI BHMA requirement for the leading edge and sensing field cut the protruding pin of the mounting bracket on the leading edge and slide the sensor brackets assembly as far as possible towards the leading edge The TopScan has been independently tested by TUV Rheinland North America and certified compliant with ANSI standards After installation it is important to test the full detection pattern described in the standard by Standing crouching in the detection area Page 5 Finishing the Installation Securing the Sensor Position When all settings are complete secure the sensor by tightening the red screws on the mounting brackets A screwdriver can be used for tightening the screws but only very low torque should be applied l im T La Closing the Housing A Remove the blue plastic 1 Attac
10. h the front cover to the aluminium housing protective film from the lens 2 Attach the end caps using the screws provided Click the plastic front cover onto the rail as shown Ensure It is se cure the entire length of the rail Use pliers to break out one Route the cable loop of the two the cable exits through the cable exit indicated on the end cap eu Troubleshooting Note The door opening refers to the TopScan on the SWING side The door closing refers to the TopScan onthe APPROACH side 1 Change the switching mode active passive see section 4 1 Door does not open close Or use the other relay output terminal NC instead of NO or vice versa see section 4 1 1 Adjust scanning range closer to the floor see section 4 2 2 Check intra unit cable amp connectors see section 3 5 3 Replace sensor Door does not open close 1 Adjust scanning range further away from the floor see section 4 2 The sensor does not detect the test object 1 Change the switching mode active passive see section 4 1 Or use the other relay output terminal NC instead of NO or vice versa see section 4 1 and adjust scanning range further away from the floor see section 4 2 Door opens closes 1 Change the operating mode to moving see section 4 1 2 Adjust the scanning range further away from the floor see section 4 2 Door only opens closes cyclically 3 Increase inclination angle further away from the door panel On and off or partiall
11. m rail 1 Remove the end caps by removing both screws 2 Remove the front cover by grasping with your fingers and pulling away from aluminum rail EFJ Mounting the Housing Alternate method slide sensor unit with attached brackets out the side of the aluminum housing 1 Fix both end caps to the aluminum rail with provided screws Loosen mounting bracket screws and slide sensors to the side to accomodate holes 2 Center aluminum rail with end caps between door jambs or hinge and place about 1 2 5 cm from the top of the door or arm fixture slide rail if applicable 3 Drill mounting holes in the aluminum rail and possibly door panel 2 holes for lt 36 3 holes for gt 36 approximately 5 12 cm from the edges 4 Attach the aluminum rail to the door panel with screws e g self tapping 5 Route the cable through the cable exit in the end cap and lead to door operator Note If the TopScan assembly is too e g through supplied cable loop long for the door the aluminum rail amp lens cover may be cut down to size For ease of cutting ensure lens amp rail are cut together as an assembly 6 If mounting a TopScan system units on both sides of door face drill a 1 4 cable hole approximately 7 18 cm from the edge Units must be mounted at the same height to route the cable properly For more information on wiring Topscan systems see section 4 2 Page 2 EE Selecting the Detection Are
12. tion between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Warning Changes or modifications to this equipment not expresssly approved by Bircher Reglomat may void the FCC authorization to ope rate this equipment AIR16 RE sensor Sensor mounting bracket Intra unit flat cable 8 2 4 m 6 wire cable Cable loop z available in 12 18 24 to connect TopScan to to protect exposed cables door operator KA Additional Parts amp Accessories amp 35 to connect multiple sensors in one housing Aluminum rail Lens cover End caps Rain protection tape available in black white for areas exposed to rain or silver 10 Declaration of Conformity Manufacturer Bircher Reglomat AG Wiesengasse 20 CH 8222 Beringen Switzerland www bircher reglomat com Importer Bircher America Inc 870 Pratt Ave N Schaumburg IL 60193 USA www bircherreglomat com Directives observed 2006 42 EC R amp TTE directive 1999 5 EC EMV directive 004 108 EC standards taken into account EN 61000 6 1 EN 61000 6 2 EN 61000 6 3 EN 61000 6 4 Important note Bircher Reglomat reserves the right to change any Information in this document without notice For the latest version please visit www bircherreglomat com or call 800 252 1272 to request a copy Page 7 41 Technical Data Specification
13. y irregular detection see section 4 4 intermittently without an object in the scanned 4 Remove reflective background zone e g dry the floor or cover floor with mat 5 Remove the fluorescent lamp e g deactivate FL CFL HID bulb in the immediate vicinity of the sensor door Page 6 a FCC Approval This device complies with Part 15 of the FCC Rules and with RSS 210 of Industry Canada Operation is subject to the following two conditions This device may not cause harmful interference This device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment gene rates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occurr in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separa