Home
CA701 - Tecnica Industriale S.r.l.
Contents
1. Hp Rating For the Operation of Permanent Magnet DC Motors Only Catalog Number 7 115 VAC 230 VAC Enclosure Rated AC Input DC Armature Rated Armature List Mult BC Series Input Input Type Line Amps KVA Voltage Current Amps Price Sym Alternate a 1 8 to 1 2 NEMA 1 4 5 to 7 8 0 5 to 0 9 90 2 7 to 5 0 1 2 to 1 0 NEMA 1 7 8 to 13 0 9 to 1 5 90 5 0 to 10 DC3N 12D 01 010 AN 250 VS3DC BC140 BC143 b 1 2 to 1 0 NEMA 1 2 6 to 7 0 0 6 to 1 6 180 1 4 to 5 0 1 0 to 2 0 NEMA 1 7 0 to 12 1 6 to 2 8 180 5 0 to 9 2 NOTE Requires addition of Heatsink Kit Option DC3N HS 01 List Price 124 00 External isolated reference source 90 VDC Armature 0 1 4 VDC reference and 180 VDC 0 2 8 VDC reference Instruction manual D2 3451 a Review dimensions and application I O functionality for complete compatibility Contact your local district office for assistance b BC143 Heatsink option required for 1 Hp 115 VAC or 2 Hp 230 VAC rating c Catalog number indicates option kits factory installed for functional equivalence DC3N Non isolated Enclosed Style Overall Dimensions Overall Enclosure Style Height Width Depth Inches mm Inches mm Inches mm NEMA 1 8 00 203 6 00 152 3 46 88 NEMA 4X 12 8 20 208 6 90 175 4 50 114 Height Width Length aE Inches mm Inches mm Inches mm DC3N HS 00 1 0 25 4 40 112 6 90 175 DC3N HS 01 1 0 25 7 78 198 6 90 175 48 BALDOR RELIAN
2. Electronic Thermal Overload Exceed Drive rating of 150 for One Minute UL cUL CE Altitude 1 000 m 3 300 ft Maximum Ambient Temperature 0 C 32 F to 40 C 104 F Storage Temperature 40 C 65 C 40 to 149 F Relative Humidity 5 to 95 non condensing Intermittent Overload 150 overload capacity for up to 1 minute 200 instantaneous overload BALDOR RELIANCEF SP500 AC Drives SP500 General Purpose AC Drive Catalog Number Frame Hp Output Current List Price Mult Sym V S Alternate a 208 2301 50 60 Hz 3 Phase Input 230 V 3 Phase Output NEMA 1 Green Enclosure 1SU21005 C 5 142 1 353 VS1AC VS1MD25 VS1MD NM1C 380 4801 50 60 Hz 3 Phase Input 460 V 3 Phase Output NEMA 1 Green Enclosure 1SU41020 D 20 27 4 012 VS1AC VS1PF420 9 VS1PFNM1C 575V 50 60 Hz 3 Phase Input 575 V 3 Phase Output NEMA 1 Green Enclosure 1SU51007 C 7 1 2 9 2 116 VS1AC VS1SP57 1B Dimensions a Height Width Depth Weight Inches mm Inches mm Inches mm Ib kg A 12 305 5 7 146 4 8 122 7 3 2 B 11 1 282 8 8 224 6 25 159 12 5 4 c 13 3 338 11 280 6 25 159 18 98 20 D 18 3 465 11 4 290 9 4 239 25 11 3 Mains Filter Mains Filter AC line filter for CE requirements is housed in a compact NEMA 1 IP21 enclosure designed for mounting between the wall or back panel and the SP500 Pre drilled and tapped holes are provided on the filter enclosure for mounting the SP500 Incoming AC
3. NEMA 4X 12 1P66 Horsepower Rating 1 a Model Number 110 OL 150 OL List VT Applications CT Applications OP9CTNN B4 0 5 0 33 0 9 1 1 4 1 645 3P9CTNN B4 3 2 3 9 4 3 5 8 2 235 9POCTNN D4 7 5 5 9 9 9 13 5 2 755 6SP54X 011CTNN D4 10 7 5 11 13 5 18 3 255 017CTNN D4 15 10 17 18 8 25 5 4 035 022CTNN D4 20 15 22 25 5 34 4 815 1 Overload of 150 or more for 1 minute Dependant upon actual motor full load amp rating versus the drive continuous amp rating 2 Rated for 600 VAC input and 4 kHz switching frequency All models are 24VDC Inputs See option AK M9 115VAC 1 on page D 39 for 115VAC Inputs FLANGE MOUNT DRIVES Up C Que e Power Rating 0 5 to 50 HP 0 33 to 37 kW e Voltage 380 400 415 480 VAC 50 60 Hz e Mounting Flange Mount as IP20 NEMA1 e Models without LCD OIM keypad use remote keypad or order separately E SP6000 Flange Mount ut Ratings 0 5 to 50 HP 380 480 VAC 50 60 Hz In Horsepower Rating Drive Amps 480 V Flanged IP20 a ees 4 With Filter 110 OL List Model Number Continuous Y CT Applications VT Applications 6SP41F 011BTAN 1 830 1 Overload of 150 or more for 1 minute Dependant upon actual motor full load amp rating versus the drive continuous amp rating 2 Rated for 480 VAC input and 4 kHz switching frequency 3 See amp rating chart for currents 400 VAC Model Numbers 6SP41F xxxBxxx are w
4. a Review dimension and application IO functionality for complete compatibility Contact your local district office for assistance 39 BALDOR RELIANCEF GV3000 Accessories and Kits GV3000 AC Drives Catalog Description List Mult Number Price Sym NEMA 1 Kits 2CK4160 25 60Hp NEMA 1 CE Compliance Cover 378 VSTAC 2CK4100 NEMA1 Conversion Kit for 75 100Hp 460V IP00 GV3000 Drives 702 VS1AC 2CK4125 NEMA1 Conversion Kit for 125Hp 460V IP00 GV3000 Drives 767 VS1AC 2CK4200 NEMA1 Conversion Kit for 150 200Hp 460V IP00 GV3000 Drives 821 VS1AC Accessories and Options 2513000 GV3000 SUPER RMI CARD 621 VS1AC 2NB3000 Interbus S Network Board 880 VSTAC 2703025 Encoder feedback cable 10 pin MS Dynapar H20 25 185 VS1AC 2704025 Encoder feedback cable 26 pin MS Tamagawa FA Series 25 195 VSTAC 21C4075 Encoder feedback cable 16 pin MS Tamagawa FA Series 75 345 VSTAC 2TC4100 Emcpder feedbacl cab e pm u Bare emds 100 345 VSTAC 2CS3000 Configuration Software Exec For GV30000 FP3000 350 VS1AC 2CS3000 Configuration Software Exec for GV30000 FP3000 350 VS1AC 2CA3000 9 pin to 9 pin interface cable 120 VS1AC 2CA3001 25 pin to 9 pin adapter cable 120 VS1AC a Review dimensions and applicagtion 10 functionality for complete compatibility Contact your local distric office for assistance 40 BALDOR RELIANCEP GV3000 AC DRIVES BRAKING LOOSE SNUBBER RESISTOR KITS FOR GV3000 SE BOOKSHELF Re
5. 3 3 0 8 84 1mm Em 148 370 mm 60 HAEDO BENANDER FLEXPAK 3000 DC Drives FlexPak 3000 Drive Options Software Programming and RS 232 Cables CS3000 Software Control and Configuration This is a Microsoft Windows based software package which allows drive Control amp Configuration The user is allowed to create store upload download monitor control and or compare parameter values in a user friendly environment Compare when performed either locally or over a remote modem allows quick qualification of any changed parameters Differences are displayed on the PC and may be printed e Edit allows programming via PC e Download allows one step programming of multiple parameters from drive memory e Upload allows identification of existing drive parameters from drive memory e Drive control Monitors 6 display values Speed reference scalable Motor speed Armature volts Motor current Percent load Configurable displays are Speed reference Control source Auto Manual mode Fwd Rev direction Operational keys displayed Run Jog Stop Reset e Fault Alarm Log allows fault and alarm history for diagnosis of operation e PC Scope feature allows monitoring and trace of two drive parameters for diagnostics angl tuning of the drive Captured data can also be saved as an ASCII text file or can be compared to previous traces Provided on a 3 5 diskette with manual
6. Note that this software is also compatible with GV3000 AC drives Reference Manual Number D2 3348 Catalog Number Mult Sym List Price 2CS3000 VS1AC 418 CS3000 Computer Cable The 9 pin connector connects to the PC and the 25 pin connector connects to the FlexPak 3000 drive Model Number 2CA3001 a Requires V4 0 or later b If a 3 5 disc drive is not available contact your local BaldoreReliance District Office for software package compatible with your PC storage c Requires Microsoft Windows 20000 or earlier version 61 e TR EDMONTON VANCOUVER PORTLAND MINNEAPOLIS M LWAUKE WINNIPEG f 7 S MONTREAL 2 7 CAT CHICAGO SALTLAKE CITY DES MOINESe seur BOSTON CLEVE WALLINGFORD DENVER KANSAS CITY PITTSBURGH AEW YORK HAYWARD e INDIANAPOLIS ILADELPHIA sT Louis CINCINNATI ALTIMORE TULSA y MEMPHIS e e LOS ANGELES cuarksviiLe GREENSBORO e FORT PHOENIX SMITH O ATLAYTA DALLAS HOUSTO DISTRICT OFFICE MONTERREY amp WAREHOUSES o TAMPA on LEON UADALAJARA TEXAS ne cr A DALLAS 9 2920 114TH STREET SUITE 100 o GRAND PRAIRIE TX 75050 PHONE 214 634 7271 UNITED STATES FAX 214 634 8874 ARIZONA HOUSTON PHOENIX NEW YORK 10355 W LITTLE YORK ROAD 4211 S 43RD PLACE AUBURN SUITE 300 PHOENIX AZ 85040 ONE ELLIS DRIVE HOUSTON TX 77041 PHONE 602 470 0407 AUBURN NY 13021 PHONE 281 977 6500 FAX 602 470 0464 PHONE 315 255 3403 FAX 28
7. SP600 Shown with LCD OIM 600 VAC 50 60 Hz Input Rating 0 5 to 50 HP Horsepower Rating Drive Amps 575 V NEMA 1 1P20 e 110 OL Model Number With Filter VT CT Continuous List Applications Applications 6SP501 9POBTNN 1 Overload of 150 of rated current for 1 minute dependant on actual motor full load amps versus drive continuous amp rating 2 Rated for 600 VAC input and 4 kHz switching frequency Model Numbers 6SP501 xxxBTNN are without OIM Model Numbers 6SP501 xxxCTNN are with OIM DISCOUNT VS 1AC 19 BALDOR RELIANCEP SP600 AC Drives WASHDOWN DRIVES UL n223 e Power Rating 0 5 to 25 HP 0 33 to 18 5 kW cairai Voltage 200 208 amp 240 VAC 50 60 Hz Enclosure NEMA 4X 12 Washdown Dustproof IP66 e Mounting Wall Machine e OIM Keypad LCD OIM factory installed ATT 200 240 VAC 50 60 Hz Input Ratings 0 5 to 25 HP Horsepower Rating NEMA 4X 12 1P66 110 OL 150 OL List Model Number VT Applications CT Applications 4P2CTAN B4 1 0 75 4 2 4 8 6 4 1 253 6P8CTNN B4 2 1 5 6 8 9 12 1 270 Peer 9P6CTNN B4 3 2 9 6 10 6 14 4 1 395 070CTAN E4 25 20 70 81 108 5 273 1 Overload of 150 or more for 1 minute Dependant upon actual motor full load amp rating versus the drive continuous amp rating 2 Rated for 240 VAC input and 4 kHz switching frequency 3 See amp rating chart for currents 208 VAC All models are 24VDC Inputs
8. The MD65 drives include power terminals for connecting low power dynamic braking resistors These resistors are not enclosed and must be separately mounted For enclosed braking resistor options reference the GV3000SE section page D 66 Select resistors from the chart on this page based on the power rating of the MD65 Also refer to the MD65 User Manual for connections and parameter setup when using braking resistors Drive Nominal Resistor Rating Value Rating W Model Number List Price HP Ohm g 230 V DB Resistor il 91 500 9 91 500 AK R2 091P500 203 3 47 500 5 47 500 AK R2 047P500 203 7 5 30 1200 10 20 1200 AK R2 030P1K2 271 1 Resistors listed in this table are rated for a 5 duty cycle 2 Requires two AK R2 120P1K2 Resistors wired in parallel MD60 MD65 Cable Accessories The MD65 drive provides an RJ45 port to allow the connection of a single peripheral device The RJ45 Splitter Cable can be used to connect a second MDI peripheral device to the drive MD60 MD65 Cable Accessories Description Model Number List RJ45 to RJ5 2 meter male to male Cable MD60 MD65 converter MDCBL RJ45 15 OIM Cable 2 9 meter OIM to RJ45 MDCBL CC3 34 MDI Splitter Cable AK U0 RJ45 SC1 17 MD60 MD65 NEMA 1 Bezel Kit The NEMA 1 Bezel Kit provides a convenient means for panel or door mounting of MD1CC CopyCat Keypad The kit includes a one meter RJ45 to RJ45 cable Model Number MDBZL N1 ssssssssnsnsn
9. Digital LCD OIM Communication options are supplied as kits See Options section 20 HP and above have 115 VAC I O option available This character not used in 6SP series model number Instruction Manuals D2 3485 6SP Series ratings from 0 5 HP to 50 HP D2 3488 v s Utilities D2 3501 6SB Series ratings from 20 HP to 200 HP D2 3485 1ES Spanish Manual User D2 3487 Operator Interface Local D2 3477 Serial Converter D2 3516 Door Mount OIM Bezel Kit D2 3478 DeviceNet D2 3490 Operator Interface NEMA 4 Large D2 3479 ProfiBus D2 3525 Operator Interface NEMA 4 Small D2 3480 Interbus S D2 3493 Dynamic Braking Kit D2 3497 ControlNet D2 3489 Dynamic Braking Selection Guide D2 3510 EtherNet IP D2 3500 PF filter Kit 15 BALDOR RELIANCET 6SP MODEL TERMINAL ASSIGNMENTS O o O eo O O a al JG O 000 O eL alo nn mnt Oy os TOR o Of O Jo o COMMUNICATION CARD TERMINAL BLOCK OPTION POWER TERMINAL BLOCK VO TERMINAL BLOCK Control Terminals Terminal Signal Name Default Functions 1 Digital In 1 Stop Clear Fault 2 Digital In 2 Start 3 Digital In 3 Function Loss 4 Digital In 4 Jog 5 Digital In 5 Auto Manual 6 Digital In 6 Speed Select 1 7 24 V Int Com Power Supply Common 8 Digital In Ext Com Logic Common 9 24 VDC Int Internal 24 V logic supply 10 10 VDC Ref Out Internal 10 V refe
10. Motor output Motor output AC line input AC line input AC line input SP600 AC Drives 4H I To0000009 60000 L En Gocccoceoccoo sh ESHLD gt La P 400 480 VAC Three phase Ratings Model Number 6SB401 Output Amps Nominal Power Ratings 110 OL 150 OL 480 VAC Input 400 VAC Input Duty Duty 027 27 33 4 30 33 45 15 20 11 15 034 34 405 54 37 45 60 185 25 15 20 040 40 51 68 43 56 74 22 30 185 25 052 52 60 80 56 64 86 30 40 22 30 065 65 78 104 72 84 112 37 50 30 40 077 77 97 130 85 128 170 45 60 37 50 096 95 106 144 105 115 158 55 75 45 60 125 125 138 163 125 138 163 55 100 45 75 156 156 172 234 170 187 255 93 125 75 100 180 180 198 270 205 220 300 110 150 100 125 248 248 273 372 260 286 390 132 200 110 150 Model Number 6SB501 575 600 VAC Three hase Ratings Output Amps Nominal Power Ratings 110 OL 150 OL 600 VAC Input Duty Duty 022 22 255 34 15 20 11 15 027 27 33 4 185 25 15 20 032 32 405 54 22 30 185 25 041 41 48 64 30 40 22 30 052 52 615 82 37 50 30 40 062 62 78 104 45 60 37 50 077 77 85 116 55 75 45 60 099 99 109 126 75 100 55 75 125 125 138 188 90 125 75
11. serial network or EtherNet e Built in online help NOTE Software requires the RECOMM 232 serial converter The RECOMM 232 serial converter comes standard with a one meter cable The cable length can be extended by e Replacing the RECBL M10 with a longer cable see table e Extending the cable with extension option DPI cables drive side of converter box cannot exceed 10 meters DPI Drive Peripheral Interface Software Serial Converter Model No RECOMM VSU232 437 Software ONLY Model Number RECOMM VSUTIL 154 SP600 NEMA 4X Remote Mount OIM Operator Interface Module Remote mountable LCD OIM for door mounting This will allow users to operate the SP600 drive from a door mounted operator interface The remote interface is supplied with a 3 meter DPI male to male cable RECBL M30 that can be extended by using the RECBL F30 F90 cables A DPI screw terminal adapter kit can also be used to extend with customer fabricated cables SP600 AC Drives m meters Note Drive DPI is a female mini din connector In order to connect to this port you need a male mini din connector RE1LCD OlMs have a Hirose connector only one type of Hirose connector is used Note DPI Screw Terminal Kits are to be utilized when a remote OIM is to be located more than 10 meters from the drive DPI Screw Terminal Kits can be used with RE4ALCD or REZL N1 OIM kits not usable with RE4LCD PNL SP600 Accessorie
12. this port you need a male mini din connector Five OIM kits are available RIMS ave a Hirose connector only one type of Hirose connector 6VKYPD STD which is the standard keypad shipped with the drive is used 14 button Note DPI Screw Terminal Kits are to be utilized when a remote OIM is GURYPD EN which is the full numeric keypad 23 button DPI Screw Terminal Kits can be used with RE4ALCD or REZL N1 16 button OIM kits not usable with RE4LCD PNL e REBLNKOIM which is the blank insert that can be utilized in the drive cover when the OIM is not present e REBZL N1 which is the door mountable bezel kit to remotely mount either bats hid lel ido pion the drive mounted keypad or the full numeric keypad 6VKYPD STD Standard OIM 182 6VKYPD N4 Remote NEMA 4 OIM 302 REBLNKOIM Blank Insert 11 DISCOUNT VS 1AC 33 BALDOR RELIANCEF SP500 AC Drives SP500 General Purpose AC Drive 1 Hp 115 VAC 1 Phase 50 60 Hz 1 thru 5 Hp 208 230 VAC 3 Phase 50 60 Hz 1 thru 20 Hp 380 460 VAC 3 Phase 50 60 Hz 1 thru 10 Hp 575 VAC 3 Phase 50 60 Hz Performance Features Drive Specifications Protective Features Agency Certifications Service Conditions 34 Control Modes V Hz Control Applications Variable torque constant torque or constant horsepower applications New installations replacements and original equipment manu factures OEM Features Volts per Hertz Control with peak overload capacity
13. 024102 C 7 5 24 04 226 1 554 380 460 V 50 60 Hz 3 Phase Model Number Frame Size HP Output Current List 40 6MDDN 2P3102 B 1 2 3A 700 6MDDN 4P0102 B 2 4 0A 60 809 6MDDN 012102 C 7 5 12 04 160 1 554 600 V 50 60 Hz 3 Phase Model Number Frame Size HP Output Current List B 3 90 6MDEN 4P2102 4 24 1 052 6MDEN 012102 C 10 12 24 200 1 837 6MDEN 019102 C 15 19 0A 285 2 261 DISCOUNT VS 1AC BALDOR RELIANCEF MD65 ACCESSORIES NEMA 1 1P30 Kit The MD65 AC drive has an enclosure rating of IP20 but includes provisions to mount a NEMA 1 IP30 kit This kit provides a metal conduit plate for attaching user conduit as well as a plastic top cover for the drive MD65 NEMA 1 1P30 Kits Description Model Number List MD65 IP30 NEMA 1 Kit Frame B 6MD NM1B 15 MD65 IP30 NEMA 1 Kit Frame B 6MD NM1COMB 28 MD65 IP30 NEMA 1 Kit Frame C 6MD NM1COMC 28 1 These NEMA 1 Kits are for use when the 6MD COMMCVRB or 6MD COMMCVRC Communication Cover Kits are installed on the MD65 drive EMC Compliance Filters The MD65 drive has been designed to conform to global industry standards for EMC compliance including Europe and Australia To meet the conducted and radiated emission standards of EN 61800 3 the filters listed below must be used depending on the motor cable length Reference the MD65 User Manual D2 3519 for details on the filters and their installation Also be sure to follow recommended wiring pr
14. 100 144 144 158 216 110 150 90 125 BALDOR RELIANCEP SP600 AC Drives WALL MOUNT DRIVES SP MODELS UL CE n223 e Motor Power Rating 0 5 to 25 HP 0 33 to 18 5 kW Input Voltage 200 208 240 VAC 50 60 Hz e Enclosure NEMA 1 Ventilated IP20 Mounting Wall Machine Panel Mount as IP20 SP600 Shown with LCD OIM e Models available with LCD OIM keypad a e Models available with internal EMC filter z er e Zero clearance side by side mounting 200 240 VAC 50 60 Hz Input Ratings 0 5 to 25 HP Horsepower Rating Drive Amps 240 V 0 0 Model Number With Filter GT continuous 1 min List Applications 4P2BTNN A 1 0 75 4 2 4 8 6 4 796 9P6CTNN B 3 2 9 6 10 6 14 4 1 179 022BTAN D 7 5 5 22 24 2 33 1 550 6SP201 028BTAN D 10 7 5 28 33 44 1 940 042CTAN D e 15 10 42 46 2 63 2 673 054BTAN E 20 15 54 63 84 3 115 070CTAN E e 25 20 70 81 108 4 108 1 Overload of 150 of rated current for 1 minute dependant on actual motor full load amps versus drive continuous amp rating 2 Rated for 240 VAC input and 4 kHz switching frequency 3 See amp rating chart for currents 208 VAC Model Numbers 6SP201 xxxBxxx are without OIM OIM option available See page D 40 for information Model Numbers 6SP201 xxxCxxx are with OIM Model Numbers 6SP201 xxxCxAx are with OIM and internal EMC filter All models are 24VDC Inputs See option AK M9 115VAC 1 on page D 39 for 115VAC In
15. 4 A 2 HP 6P0 6 A 3 HP 010 10A 5 HP 012 12A 7 5 HP 017 17 A 10 HP 024 24 A 15 HP 575 VAC 1P7 1 7 A 1 HP 3P0 3 0 A 2 HP 4P2 4 2 A 3 HP 6P6 6 6 A 5 HP 9P9 9 9 A 7 5 HP 012 12A 10 HP 019 19 A 15 HP MD AC Driv BALDOR RELIANCEF 65 AC es PRICING Single phase 115 VAC and 208 230 VAC Three phase 208 230 VAC 380 460 VAC and 600 VAC Product Features e P20 enclosure as standard modifiable to NEMA 1 IP30 e Integral keypad and display including single turn speed potentiometer Power ratings up to 15 HP with both single phase and three phase input ratings e Built in braking transistor allows connection to remote braking resistor for enhanced performance needs 100 115 V 50 60 Hz 1 Phase Input 230 V 3 Phase Output Model Number FrameSize HP OutputCurrent WattLoss List B 0 5 6MDVN 2P3102 2 3A 30 530 200 240 V 50 60 Hz 1 Phase Input 230 V 3 Phase Output With Integral EMC Filter Model Number FrameSize HP Output Current WattLoss List 30 6MDAN 2P3112 B 0 5 2 3A 435 200 230 V 50 60 Hz 1 Phase Input 230 V 3 Phase Output ec e a Number FrameSize HP OutputGurrent WattLoss List 6MDAN 2P3102 B 0 5 2 3A 30 417 6MDAN 5P0102 B 1 4 5A 55 491 200 230 V 50 60 Hz 3 Phase Model Number Frame Sze NP Output current Uist 0 5 30 6MDBN 2P3102 B 2 3A 543 6MDBN 8P0102 B 2 8 0A 80 774 6MDBN 017102 B 5 17 5A 165 1 056 6MDBN
16. 40 65 78 104 7 153 6V41 096NA 5 X TA 79 60 96 106 144 9 511 6V41 156NA 6 X 125 100 156 172 234 12 766 6V41 248TA 6 X X 200 150 248 273 372 20 020 1 Overload of 150 of rated current for 1 minute dependent on actual motor full load amps versus drive continuous amp rating 2 Rated for 480VAC input and 4 kHz switching frequency 248 Amp Unit 2kHz 3 See amp rating chart for currents 400 VAC DISCOUNT VS 1AC 31 BALDOR RELIANCET GV6000 Options The GV6000 Product Family is easily modified with a full line of optional kits and accessories including communi cations resistors filters OIMs and cables Braking Resistor Kits Low Energy Frames 0 1 and 2 GV6000 drives include mounting provisions for low energy braking resistors Dependent upon the drive power rating these resistors will provide momentary braking capacities of about 6 10 duty cycle enough to handle most simple deceleration needs as well as speed overshoot correction Consider other braking options from the GV3000 SE section of this catalog should more braking capacity be required 208 240 VAC Braking Resistors Model Number Frame Brake Resistance List 6XX2 DB1 1 1 2 5 Hp 62 Ohms 156 6XX2 DB2 1 1 7 5 Hp 22 Ohms 156 380 480 VAC Braking Resistors Model Number Frame Brake Resistance List 6XX4 DB1 0 0 1150hms 156 Communication Modules Network Options Network connectivity can be achieved by adding one of the options listed below
17. 45 78 85 8 12 372 VS1AC GV3000 Closed Loop Vector Power Module Open Enclosure Catalo Heavy Duty Normal Duty List Mult Number Hp kW Cont Amps PeakAmps Hp kW Cont Amps PeakAmps Price sym eme 230 Volts Three Phase Input 30V2060 30 22 4 105 157 5 30 224 105 115 5 9 153 VSTAC VS1GV230 1B 40V2060 40 30 135 202 5 40 30 135 148 5 9 669 VSTAC VS1GV240 1B 50V2060 50 37 3 150 225 50 37 3 150 165 10 834 VSTAC VS1GV250 1B 60V2060 60 45 195 292 5 60 45 195 214 5 12 904 VSTAC VS1GV260 1B 75V2060 75 56 245 367 5 75 56 245 269 5 13 979 VSTAC 100 2060 100 75 275 412 5 100 75 275 302 5 16 184 VSTAC 460 Volts Three Phase Input 30V4060 30 22 4 40 60 30 224 40 44 7 074 VSTAC VS1GV430 1B 40V4060 40 30 54 81 40 30 54 59 7 818 VSTAC VS1GV440 1B 50V4060 50 37 3 67 100 50 37 3 67 74 8 813 VSTAC VS1GV450 1B 60V4060 60 45 78 117 60 45 78 86 10 192 VSTAC VS1GV460 1B GV3000 Closed Loop Vector Amp Rated IP20 Bookshelf Enclosure Catalo Heavy Duty Normal Duty List Mult Humber Cont Amps Peak Amps Cont Amps Peak Amps Price Sym VYS Alternate 4 460 Volts Three Phase Input w O EMI Filter 31ER4060 2 1 3 2 3 1 3 4 1 804 VS1AC VS1GV41 1B 38ER4060 3 1 47 3 8 4 2 1 827 VS1AC VS1GV42 1B 460 Volts Three Phase Input w EMI Filter 31ET4060 2 1 3 2 3 1 3 4 2 044 VS1AC E 38ET4060 3 1 4 7 3 8 4 2 2 090 VS1AC NN 55ET4060 3 8 5 7 5 5 6 1 2 124 VS1AC a 240ET4060 16 5 24 8 24 26 4 3 737 VS1AC a 300ET4060 22 33 30 33 4 682 VS1AC NN
18. 648 5895 CANADA EDMONTON ALBERTA 4053 92 STREET EDMONTON ALBERTA T6E 6R8 PHONE 780 434 4900 FAX 780 438 2600 TORONTO OAKVILLE ONTARIO 2750 COVENTRY ROAD OAKVILLE ONTARIO L6H 6R1 PHONE 905 829 3301 FAX 905 829 3302 MONTREAL QUEBEC 5155 J ARMAND BOMBARDIER SAINT HUBERT QUEBEC CANADA J3Z 1G4 PHONE 514 933 2711 FAX 514 933 8639 VANCOUVER BRITISH COLUMBIA 1538 KEBET WAY PORT COQUITLAM BRITISH COLUMBIA V3C 5M5 PHONE 604 421 2822 FAX 604 421 3113 WINNIPEG MANITOBA 54 PRINCESS STREET WINNIPEG MANITOBA R3B 1K2 PHONE 204 942 5205 FAX 204 956 4251 AUSTRALIA UNIT 3 6 STANTON ROAD SEVEN HILLS NSW 2147 AUSTRALIA PHONE 61 2 9674 5455 FAX 61 2 9674 2495 UNIT 8 5 KELLETTS ROAD ROWWVILLE VICTORIA 3178 AUSTRALIA PHONE 61 3 9753 4355 FAX 61 8 9753 4366 EL SALVADOR RESIDENCIAL PINARES DE SUIZA POL 15 44 NVA SAN SALVADOR EL SALVADOR PHONE 503 2288 1519 FAX 503 2288 1518 CHILE LUIS THAYER OJEDA 166 OF 402 PROVIDENCIA SANTIAGO CHILE PHONE 56 2 816 9900 CHINA 160 SONG SHENG ROAD SONGJIANG INDUSTRY ZONE SHANGHAI 201613 CHINA PHONE 86 21 5760 5335 FAX 86 21 5760 5336 GERMANY HERMANN HEINRICH GOSSEN 3 50858 KOLN GERMANY PHONE 49 2234379410 FAX 49 22343794164 DIESELSTRASSE 22 D 85551 KIRCHHEIM MUNICH GERMANY PHONE 49 89 90 5080 FAX 49 89 90 50 8492 INDIA 14 COMMERCE AVENUE MAHAGANESH COLONY PAUD ROAD PUNE 411038 MAH
19. 9 44 240 0 8 67 220 2 6 76 171 7 4 83 122 7 8 0 203 0 7 95 3 61 C 11 81 300 0 11 25 285 6 7 28 185 0 5 42 137 6 7 08 179 8 15 18 6 89 D 13 78 350 0 13 21 335 6 8 66 219 9 6 65 169 0 7 08 179 8 20 4 9 25 D4 13 78 350 0 13 21 335 6 8 66 219 9 6 65 169 0 8 3 211 0 20 12 9 13 E 21 88 555 8 19 33 491 0 11 04 280 3 7 87 200 0 8 15 207 1 41 0 18 6 E4 21 88 555 8 19 33 491 0 11 04 280 3 7 87 200 0 8 65 219 8 41 0 18 6 2 13 48 342 0 12 6 320 0 8 74 222 0 7 56 192 0 7 87 200 0 27 6 12 5 3 20 37 517 0 19 7 500 0 8 74 222 0 7 56 192 0 7 87 200 0 40 9 18 55 4 29 9 759 0 29 1 738 2 8 74 222 0 7 56 192 0 7 94 201 7 54 0 24 5 5 25 4 644 0 24 6 625 0 12 2 309 0 8 86 225 0 10 9 275 0 82 0 37 2 6 125 to 150 HP 38 43 976 0 32 48 825 0 15 90 404 0 11 81 300 0 10 85 276 0 157 5 71 4 6 200 HP 38 43 976 0 32 48 825 0 15 90 404 0 11 81 300 0 10 85 276 0 165 5 75 1 1 C C center hole to center hold inches mm lbs kg 6SP SP Series SP600 6SB SB Series SP600 Voltage 6SP 201 2P2BTNN A 2 200 240 volts 4 460 480 volts 5 575 600 volts Enclosure 01 NEMA 1 1F NEMA 1 Flange 4X NEMA 4X 12 1 0 Interface A 24 VDC I O B 115 VAC I O Network N None Input Filter A EMC Filter N No Filter Braking Device T Transistor N None Keypad f B Blank OIM Nominal Amps 2P2 2 2 Amps 028 28 0 Amps L_C
20. Current d014 Digital Input Status d004 Output Voltage d015 Comm Status d005 DC Bus Voltage d016 Control SW Version d006 Drive Status d017 Drive Type d007 Fault 1 Code d018 Elapsed Run Time d008 Fault 2 Code d019 Testpoint Data d009 Fault 3 Code d020 0 10 V Analog Input d010 Process Display d021 4 20 mA Analog Input d024 Drive Temp MD AC Driv BALDOR RELIANCEF 60 AC es Mounting Dimensions Dimensions are in millimeters and inches Weights are in kilograms and pounds Front View Front View 2 A mames al D E d oe e ff K 185 136 67 152 59 3 140 hi F 8 15 7 28 5 35 2 64 5 98 2 33 5 51 3 1 el 100 213 136 87 180 87 4 168 2 2 HK 3 94 8 39 6 35 3 43 7 09 3 44 6 61 4 9 1 Height dimension includes NEMA 1 1P30 kit Height dimension for standard IP20 unit without NEMA 1 1P30 kit N it il D M Aa y LS F ia 6MD VN 1P51 11 Y 6MD MD Drive 5 5 0 22 MIDES Front Side 1 A 1 Phase 240 VAC 0 Not Filtered V 1 Phase 115 VAC Fil B 3 Phase 230 VAC AAA Bottom View with NEMA 1 1P30 Kit D 3 Phase 460 VAC N IP20 Open Reserved 115V 230 VAC 1P5 1 5 0 25 HP 2P3 2 3 0 5 HP 4P5 4 5 1 HP 6P0 6 0 A 1 5 HP 8P0 8 2
21. DISCOUNT VS 1AC BALDOR RELIANCEF PEA OS For applications from 0 5 to 15 HP the MD65 is a OL simple Sensorless Vector AC Microdrive that can be panel mounted as well as wall or machine mounted Following on the success of the MD60 the MD65 continues to establish the reliability and ease of use expected on the Reliance Electric brand drives PERFORMANCE FEATURES e Input Voltage Tolerance e Communication Option Card e Adjustable Current Limit Typically 10 DeviceNet 10 to 150 e Rated Input Frequency EtherNet e Operator Interface Module 50 60 Hz 47 63 Hz Range Profibus Integral Drive Mounted e Carrier Frequency e Serial Communications e Display Lines 2 16 kHz 4 kHz default RS 485 Included for Optional PC 4 Character LED Display e Operating Temperature Interface Program e Programmable Preset Speeds 10 to 50 C IP20 e PID Control Eight e Snubber Dynamic Braking Included e Analog Outputs Built in Transistor One 0 10 VDC or 4 20mA e Dynamic Braking External PROTECTIVE FEATURES e Auto Restart Resistor Terminals or DC Bus e Power Loss Rid Through Yes for Snubber Kit 500 Milliseconds e Frequency Avoidance e DC Braking e Under Voltage One Band Included Level Depends on Voltage Class e Fault Memory e Volts Hz 240 480 or 575 Three Deep Custom V Hz Curve e Ground Fault e Digital Inputs Speed Regulation Phase to Ground on Drive Output Four Logic Configurable 2 of
22. HP 012 12 A 3 HP 017 17 5 A 5 HP 460 VAC 1P4 1 4 A 0 5 HP 2P3 2 3 1 HP 4P0 4 A 2 HP 6P0 6 3 HP 8P7 8 7 A 5 HP Instruction Manuals MD60 Kit Instruction Manuals MD60 User Manual D2 3499 NEMA 1 Kit D2 3503 MD60 Data Sheet RAPS 1520 Input EMI Filters Installation Instructions D2 3504 MDCOMM 232 Serial Converter Module D2 3502 Service Conditions V S Utilities Software D2 3488 Altitude 1 000 m 3 300 ft Maximum OIM User Guide D2 3534 Ambient Temperature IP20 10 C 14 F to 50 C 122 F OIM Quick Reference D2 3508 NEMA 1 1P30 10 C 1 4 F to 40 C 1 04 F Remote Large OIM Installation Instructions D2 3509 Storage Temperature 40 C 40 F to 85 C 185 F Remote Small OIM Installation Instructions D2 3526 Relative Humidity 0 to 95 non condensing Door Mount NEMA 1 OIM Bezel Kit D2 3517 Speed Regulation 2 of base speed across a 40 1 speed range Cable Accessory Kits RA INOOSA EN P Intermittent Overload 150 overload capacity for up to 1 minute DB Resistor Kits RA INOO4A EN P 200 overload capacity for up to 3 seconds riv BALDOR RELIANCEF MD60 AC Drives PRICING Single phase 115 VAC and 208 230 VAC Three phase 208 230 VAC 380 460 VAC Product Features e P20 enclosure as standard modifiable to NEMA 1 IP30 e Integral keypad and display including single turn speed potentiometer e Power ratings up to 5 HP with both single phase and three phase input ratings e Built in bra
23. M3575TH15 M4 746 150 780 1 834 2 6 M3575RH2M M3575TH15 M4 1492 100 390 2 736 2 20 M3575RH2MF M3575TH15 M4 1492 300 390 2 886 3 20 M3575RH3MF M3575TH15 M4 2238 450 260 3 942 4 20 M3575RH4MF M3575TH15 M7 2984 600 195 4 1 025 5 6 M3575RH5B M3575TH15 B4 4000 200 150 5 865 5 20 M3575RH5BF M3575TH15 B4 4000 800 150 5 1 056 6 6 M3575RH6M M3575TH15 M7 4476 300 130 6 958 6 20 M3575RH6MF M3575TH15 M7 4476 900 130 6 1 123 8 6 M3575RH8B M3575TH15 B4 6000 300 90 8 973 8 20 M3575RH8BF M3575TH15 B4 6000 1200 90 8 1 138 9 6 M3575RH9M M3575TH15 M10 6714 450 87 9 1 128 9 20 M3575RH9MF M3575TH15 M10 6714 1350 87 9 1 391 16 6 M3575RH16B M3575TH30 B7 12000 600 45 16 1 148 24 6 M3575RH24B M3575TH30 B10 18000 900 30 24 1 257 27 20 M3575RH27BF M3575TH30 B10 21800 4000 25 7 27 1 700 33 20 M3575RH33BF M3575TH75 B10D 2500 4920 22 5 32 1 868 50 20 M3575RH50G1F M3575TH75 Gi 40000 8000 14 53 5 361 100 20 M3575RH100G2F M3575TH125 G2 80000 16000 7 106 6 983 43 BALDOR RELIANCEF GV3000 AC Drives BRAKING PRE PACKAGED SNUBBER TRANSISTOR RESISTOR KITS us TAA Complete Snubber Transistor Resistor Brake Kits NEMA 1 Enclosed For Deceleration of High Inertia Loads as well as for correction of speed command overshoot Snubber Resistor Kits dissipate excess DC Bus energy into heat thereby allowing quick step change command s in both acceleration and deceleration Snubber Resistor Kits include both the transistor circuitry and resistor elements in a
24. Mains Filter Mains Filter AC line filter for CE requirements is housed in a compact NEMA 1 IP21 enclosure designed for mounting between the wall or back panel and the SP500 Pre drilled and tapped holes are provided on the filter enclosure for mounting the SP500 Incoming AC power must be routed into the top of the filter Outgoing AC power is then routed from the bottom of the filter to the bottom of the SP500 Mounting hardware and flying leads from the Mains Filter are provided Mains Filter 2DF2282 is rated for 1 phase or 3 phase 50 60 Hz 250 VAC max Mains filters 2DF4283 2DF4284 and 2DF4285 are rated for 3 phase 50 60 Hz 500 VAC max Hp SP500 Mains Filter List Price Mult Model Number Model Number Sym 3 1SU21003 2DF4283 735 VS1AC 5 1SU21005 2DF4283 735 VS1AC 7 1 2 1SU41007 2DF4284 827 VS1AC 10 1SU41010 2DF4284 827 VS1AC 15 1 1SU41015 2DF4285 2 160 VS1AC 20 1 1SU41020 2DF4285 2 160 VS1AC For 15 Hp and 20 Hp SP500 a cover kit and a filter kit are both required to conform to CE requirements Low Energy Snubber Braking Kit Low Energy Snubber Braking Kit provides rapid deceleration of the drive motor by providing 150 intermittent braking of the motor The kit dissipates the power regenerated by the motor during deceleration through resistors The braking resistors are sized to provide a maximum of three stops per minute taking 4 seconds for a complete stop when the motor is connected to a load that has
25. Model Number List RECOMM CNET ControlNet 468 RECOMM PBUS Profibus 494 RECOMM IBUS Interbus S 676 RECOMM 485 RS485 DF1 307 CE amp C Tick External Mount EMC Compliance Filter Kits GV6000 drives are designed to meet Global Industry Standards including those of Europe CE and Australia C Tick EMC compliance for both conducted and radiated noise emissions can be met with internally mounted EMC filters included in each drive per the below table Also be sure to follow recommended wiring practices for drives and motors as identified in our product manuals as well as those of each region Drive Input Voltage Frame CE Filter 208 230V AC 0 3 Yes 208 230V AC 4 6 Yes 380 460V AC 0 6 Yes 600V AC 0 6 Yes Note CE Certification testing has not been performed on 600V class drives GV6000 AC Drives V S Utilities Monitoring and Configuration Software This windows based software package allows online configuration and monitoring of the GV6000 AC drives This software utility allows the user to upload download monitor and compare parameter values in a user friendly environment VS Utilities runs under Windows 98 NT ME 2000 XP V S Utilities Features e Custom views for monitoring selected parameters e Compare drive parameter settings to Defaults Saved files e Point to point or multi drop capabilities serial network or EtherNet e Built in online help Note Software requires the RECOMM 232 serial converter The RECOMM 232 se
26. Utilities D2 3477 Serial Converter 28 BALDOR RELIANCEP GV6000 AC Drives Terminal Assignments Control Terminals Terminal Factory Default 1 Analog Int Volts mA pe i a 7 These inputs outputs are dependent on a number of parameter settings 4 Analog In2 Volts mA 5 Pot Common 6 Analog Out 1 Volts mA ee e ps e These inputs outputs are dependent on a number of parameter settings 9 Analog Out 2 Volts mA 10 HW PTC Input 1 Motor Temperature 11 Digital Out 1 N C Fault 12 Digital Out 1 Common 13 Digital Out 1 N O NOT Fault 14 Digital Out 2 N C NOT Run 15 Digital Out 2 3 Common 16 Digital Out 3 N O Run 17 Analog In 1 18 Current Input Jumper 19 Analog In 2 20 Current Input Jumper 21 10V Pot Reference 22 10V Pot Reference 23 HW PTC Input 2 Motor Temperature 24 24V DC Not available on 115 VAC Versions 25 Digital In Common 26 24V Common Not available on 115 VAC Versions 27 Digital In 1 Stop CF 28 Digital In 2 Start 29 Digital In 3 Function Loss 30 Digital In 4 Jog 31 Digital In 5 Auto Man 32 Digital In 6 Can be set for hardware enable Speed Sel 1 Encoder Terminals Terminal Function 1 Encoder A Channel A Input 2 Encoder A NOT Channel A Differential Input 3 Encoder B Channel B Input 4 Encoder B NOT Channel B Differential Input 5 Encoder Z Channel Z Input Marker Pulse 6 Encoder Z NOT Channel Z Different
27. WASHDOWN DRIVES W CE Onz e Power Rating 0 5 to 50 HP 0 33 to 37 kW e Voltage 380 400 415 amp 480 VAC 50 60 Hz e Enclosure NEMA 4X 12 Washdown Dustproof IP66 e Mounting Wall Machine Panel Mount as IP20 e OIM Keypad LCD OIM factory installed COMPONENT AAA AAA AMAnA 380 480 VAC 50 60 Hz Input Ratings 0 5 to 50 HP Horsepower Rating Drive Amps 480 V PA ES 110 OL 150 0LW List Model Number Continuous VT Applications CT Applications 1P1CTAN B4 0 5 0 33 qa 1 2 1 6 1 503 2P1CTAN B4 1 0 75 21 2 4 3 2 1 568 3P4CTNN B4 2 1 5 3 4 45 6 1 665 005CTNN B4 3 2 5 55 15 1 945 6SP44X DO5CTAN B4 3 2 5 5 5 7 5 2 033 011CTAN D4 15 5 11 121 16 5 2 735 014CTAN D4 10 7 5 14 16 5 22 2 955 027CTAN D4 20 15 27 33 44 4 545 052CTAN E4 40 30 52 60 80 8 668 1 Overload of 150 or more for 1 minute Dependant upon actual motor full load amp rating versus the drive continuous amp rating 2 Rated for 480 VAC input and 4 kHz switching frequency 3 See amp rating chart for currents 400 VAC DISCOUNT VS 1AC 20 BALDOR RELIANCEF SP600 AC Drives WASHDOWN DRIVES U e Power Rating 0 5 to 50 HP 0 33 to 37 kW compone Voltage 575 600 VAC 50 60 Hz e Enclosure NEMA 4X 12 Washdown Dustproof IP66 Mounting Wall Machine Panel Mount as IP20 OIM Keypad LCD OIM factory installed IBARRA RANA AAAARAA 600 VAC 50 60 Hz Input Ratings 0 5 to 50 HP
28. are associated with more advanced use This simplifies setup and minimizes customer exposure to unwanted parameters during startup During use the operator can monitor as many as 22 D Parameters to display values such as Output Frequency Output Current Output Voltage as well as the status of specific 1 0 points and the firmware version level Fault conditions are identified by alpha numeric codes such as F2 Each MD60 AC Drive has a label adhered to its left side providing a description of the Fault Codes as well as the most common Display and Basic Configuration Parameters to help in setup and during use APPLICATION CONSIDERATIONS The MD60 is a Volts per Hertz controller which is suitable for general purpose use in a multitude of applications Listed below are some of the Advanced Parameter functions which are useful when configuring the MD60 VARIABLE TORQUE USE Centrifugal fans and pumps are well suited for the MD60 which will provide good speed control beyond the 10 1 speed range normally required by these applications i e 180 to 1800 RPM Some the advanced parameter functions that can be considered during setup and operation include e Output Carrier Frequency selection which is adjustable from 2 to 16 kHz to achieve low acoustic motor operation e Reverse Disable since fans and pumps are uni directional and can become damaged if inadvertently operated in reverse e Auto Restart with up to 9 attempts alo
29. motor base speed e Output Short Circuit 40 1 Operating Speed Range Phase to Phase on Drive Output DRIVE SPECIFICATIONS e Sensorless Vector e Over Temperature Heatsink Monitor e Analog Inputs Two Total With Autotune e Output Voltage 0 10 VDC One Speed Regulation 1 of motor base DC Bus 4 20 mA One speed e Drive Overload Digital Outputs Two Opto coupled Configurable 60 1 Operating Speed Range Frequency Control Range Exceed Drive rating of 150 for One Minute e Relay Outputs 0 400 Hz e Over Current One Form C Configurable e Accel Decel Hardware Overcurrent Circuit Software e Meter Outputs Independently Adjustable Two Overcurrent Fault 0 10 VDC One Analog Usable e Time Range for Meter Configurable 0 1 to 600 Seconds AGENCY CERTIFICATIONS e Maximum Load e S Curve Acceleration e Listings 15 HP O 600 VAC Yes UL cUL CE C Tick e Overload Capacity e Din Rail Mount Drive Output 150 for One Minute 200 for Three Seconds Yes on B Frame Integral Speed Pot e Frequency Accuracy Yes Digital Keypad 0 5 of Set e Sink Source Inputs Output Selectable 24 VDC Logic Digital Keypad 0 5 of Maximum Output Frequency Electronic Overload Trip Electronic Motor Overload Class 10 Protection BALDOR RELIANCET MD 65 AC Drives DRIVE RATINGS Drive Ratings Output Model Input Voltage kw HP Enea ons Frame Size 20V 50 60 Hz 0 4 0 5 2 3A GMDVN 2P3102 B
30. seconds GV3000 AC DRIVES 230 V Snubber Resistor Kits Snubber Braking HP Duty Cycle Resistor Module Model Number Use with Transistor Module Model Number Cabinet Style Braking Watts Peak Cont Load Ohms Amp Rating List 1 6 M3575RL1M M3575TL15 M4 746 50 190 2 690 1 20 M3575RL1MF M3575TL15 M4 746 150 190 2 834 2 20 M3575RL2MF M3575TL15 M4 1492 300 95 4 886 3 6 M3575RL3M M3575TL15 M4 2238 150 63 6 788 3 6 M3575RL3B M3575TL15 B4 1989 100 75 5 721 3 20 M3575RL3MF M3575TL15 M4 2238 450 63 6 987 3 20 M3575RL3BF M3575TL15 B4 1989 400 75 5 878 4 6 M3575RL4M M3575TL15 M7 2984 200 48 8 855 4 20 M3575RL4MF M3575TL15 M7 2984 600 48 8 1 025 5 6 M3575RL5B M3575TL15 B4 3979 200 38 10 783 5 20 M3575RL5BF M3575TL15 B4 3979 800 38 10 932 6 6 M3575RL6M M3575TL15 M7 4476 300 32 12 958 6 20 M3575RL6MF M3575TL15 M7 4476 900 32 12 1 128 8 20 M3575RL8BF M3575TL15 B4 5968 1200 25 15 989 9 6 M3575RL9M M3575TL30 M10 6714 450 21 18 1 123 9 20 M3575RL9MF M3575TL30 M10 6714 1350 21 18 1 396 11 6 M3575RL11B M3575TL30 B7 7957 400 19 20 922 11 20 M3575RL11BF M3575TL30 B7 7957 1600 19 20 1 159 16 6 M3575RL16B M3575TL60 B7 11936 600 13 31 1 051 16 20 M3575RL16BF M3575TL60 B7 11936 2400 13 31 1 282 24 6 M3575RL24B M3575TL60 B10 17904 900 8 47 1 262 24 20 M3575RL24BF M3575TL60 B10 17094 3600 8 47 1 571 460V Snubber Resistor Kits 1 6 M3575RH1M M3575TH15 M4 746 50 780 1 695 1 20 M3575RH1MF
31. wall mountable open ventilated enclosure Note Maximum On rating is 60 seconds Snubber Resistor Module For sizing instructions refer to the calculations on page D xvi S Enclosed Dimensions tyle Height Depth 18 2 476 9 5 241 8 5 216 18 2 476 11 5 292 10 5 267 E A Snubber Model E Resistance Cont Watt Instant Watt Continuous Duty Drive Rating Number Cabinet Style Value Dissipation Dissipation Cycle ii 1 HP 230 V 2SR20400 B 30 400 4 000 50 2 508 2 HP 230 V 2SR20400 B 30 400 4 000 30 2 508 2SR204 B 30 400 4 000 209 2 3 HP 230V SR20400 508 2SR21200 B 10 200 12 000 50 2 925 25R21200 B 10 1 200 12 000 30 2 925 5 HP 230 V 2SR21800 C 6 1 800 18 000 50 3 744 2SR21200 B 10 1 200 12 000 30 2 925 7 1 2 HP 230 V 2SR21800 C 6 1 800 18 000 50 3 744 2SR21200 B 10 1 200 12 000 20 2 925 10 HP 230 V 2SR21800 C 6 1 800 18 000 40 3 744 1 HP 460 V 2SR40400 B 120 400 4 000 50 2 699 2 HP 460 V 2SR40400 B 120 400 4 000 30 2 699 3 HP 460 V 2SR40400 B 120 400 4 000 20 2 699 DISCOUNT VS 1AC 44 BALDOR RELIANCEE GV3000 AC DRIVES BRAKING LOOSE SNUBBER TRANSISTOR KITS amp RESISTOR INFORMATION Snubber Transistor Braking Kits Transistor Only Enclosed Chassis For deceleration of high inertia loads as well as for correction of speed command overshoot Snubber Transistor Braking Kits provide the circuitry needed to conn
32. 0 901FK2401 600 901FK2501 a Enclosure not included in price Conversion Kit 460 VAC to 230 VAC This kit contains control transformer fuses that allows the user to convert a 460 VAC FlexPak 3000 to a 230 VAC drive at on half the 460 VAC horsepower rating This kit cannot be used with FlexPak 3000 Power Module Drives A fuse kit is not required to convert 200 600 Hp 460 VAC FlexPak 3000 drives to 230 VAC The Control Circuit Transformer must be re connected for 230 VAC Contact a Baldor representative for assistance P oaie List Price This fuse kit will convert Mut sym Ordered with Drive FLEXPAK 3000 75 150 Hp 460 VAC to Hp at 230 VAC VS50D List Price Ordered Separately 50 Catalog Number 916FK0200 57 BALDOR RELIANCEF FLEXPAK 3000 DC Drives FlexPak 3000 Drive Options Dynamic Braking DB 240 VDC Dynamic Braking Loose Parts Kit Hp Rating Catalog Number Mult Sym Kit List 2 3 912FK0030 VS50D 850 5 912FK0050 VS50D 850 7 1 2 912FK0070 VS50D 885 10 912FK0100 VS50D 940 15 912FK0150 VS50D 940 20 912FK0200 VS50D 1 220 25 912FK0250 VS50D 1 220 30 912FK0300 VS50D 1 250 40 912FK0400 VS50D 1 500 50 912FK0500 VS50D 1 800 60 912FK0500 VS50D 1 800 500 VDC Dynamic Braking Loose Parts Kit 3 913FK0030 VS50D 880 5 913FK0050 VS50D 880 7 1 2 913FK0070 VS50D 880 10 913FK0100 VS50D 1 135 15 9
33. 0 VAC drives listed below with required 916FK0100 460 VAC 230 VAC conversion kits 240 VDC Armature 150 VDC Field Full Load Rated 2 Full Load RMS Rated Field Catalog Mult List Hp Rating AC Line Current DC Armature Current Number Sym Price Current 1 1 2 10 7 10 3FR4042 VS50D 4 380 Dimensions Height Depth Weight Catalog Number MN Inches mm Inches mm Ibs kg All 230 VAC 460 VAC Converted catalog numbers 1 1 2 through 30 Hp 10 65 270 5 18 79 477 3 12 23 310 6 58 26 4 50 FLEXPAK 3000 DC Drives BALDOR RELIANCET 230 VAC 50 60 Hz Non Regenerative 40 Hp 75 Hp 230 VAC drives listed below use equivalent rated 460 VAC drives with required 916FK0200 460 VAC 230 VAC conversion kits 240 VDC Armature 150 VDC Field Full Load Rated y Full Load RMS Rated Field Catalog Mult List Hp Rating AC Line Current g Current Number Sym Price 60 186 218 15 125FN4042 VS50D 7 140 Dimensions Height Depth Weight Catalog Number gt l Inches mm Inches mm Ibs kg AIN VAC catalog numbers 18 11 460 490 19 29 13 46 341 9 122 55 40 through 75 Hp 51 BALDOR RELIANCEF FLEXPAK 3000 DC Drives FlexPak 3000 Digital DC Drives E 230 VAC 50 60 Hz Regenerative 100 Hp 150 Hp 230 VAC catalog numbers do not exist for these Hp ratings Use a 460 VAC drive at 2X Hp rating and reconnect control power transformer for 230VAC operation at startup 240 VDC Armature 150 VDC Field Full Load
34. 00 11 81 X 254 10 19 1 42 DISCOUNT MS 1AC 25 BALDOR RELIANCEF The Multi Purpose High Performance Industrial AC Drive that solves virtually all stand alone or coordinated system drive applications with a common platform The Reliance Electric GV6000 utilizing the latest in vector control technology is a multi purpose drive incorporating V Hz Sensorless Vector and Flux Vector control in one product Whether your applications are simple fans or pumps or more complex applications such as web processing systems where the ultimate in performance is required the Reliance Electric GV6000 drive will meet your application needs while providing you a common platform that is expandable and the easiest to use in its class GV6000 AC Drives The Reliance Electric GV6000 package provides simplicity and broad application flexibility with the performance you need in an ultra compact zero stackable bookshelf design Ideal for stand alone retro fit or for integration into new system designs where high power density is required STANDARD FEATURES A zero stacking bookshelf design with 3 methods of control as standard e General Purpose Scalar V Hz e Sensorless Vector Control SVC e Flux Vector Control FVC Each method provides a cost effective means to address the wide range of applications required by today s demanding drives customers All methods are standard without the need for expensive or complicate
35. 00 SE Book Braking Braking inches Peak Braking Continuous shelf Model Number HP Duty Cycle Pasion Module inches Watts Braking Watts Load Amp Rating Model Number Ohms WxHxD 1 6 M3575RH1M 4x 12 75 x 8 7 746 780 1 695 1 20 M3575RH1MF 4x 12 75 x 8 7 746 150 780 1 834 2 6 M3575RH2M 4x 12 75 x 8 7 1492 100 390 2 736 31ER 31ET4060 2 20 M3575RH2MF 4x 12 75 x 8 7 1492 300 390 2 886 38ER 38ET4060 3 20 M3575RH3MF 4x 12 75 x 8 7 2238 450 260 3 942 55ER 55ET4060 4 20 M3575RH4MF 7X 12 75 x 8 7 2984 600 195 4 1 025 85ER 85ET4060 5 6 M3575RH5B 4x 17 75 x 8 7 4000 200 150 5 865 5 20 M3575RH5BF 4x17 75 x 8 7 4000 800 150 5 1 056 6 6 M3575RH6M 7X 12 75 x 8 7 4476 300 130 6 958 6 20 M3575RH6MF 7X 12 75 x 8 7 4476 900 130 6 1 123 8 6 M3575RH8B 4x 17 75 x 8 7 6000 300 90 8 973 126ER 126ET4060 8 20 M3575RH8BF 4x 17 75 x 8 7 6000 1200 90 8 1 138 150ER 150ET4060 9 6 M3575RH9M 10 x 12 75 x 8 7 6714 450 87 9 1 128 9 20 M3575RH9MF 10 x 12 75 x 8 7 6714 1350 87 9 1 391 300ER 300ET4060 16 6 M3575RH16B 7X 17 75 x 9 2 12000 600 45 16 1 148 430ER 430ET4060 24 6 M3575RH24B 10 x 17 75 x 9 7 18000 900 30 24 1 257 DISCOUNT VS 1AC 41 BALDOR RELIANCEP GV3000 AC Drives BRAKING LOOSE SNUBBER TRANSISTOR KITS 8 SNUBBER RESISTOR KITS Snubber Transistor Braking Kits Transistor Only Protected Enclosure IP20 Type For deceleration of high inertia loads as well as for correction of speed command overshoot Snubber Transistor Braking Kits
36. 1 977 6510 FAX 315 253 9023 ARKANSAS INDIANA UTAH CLARKSVILLE INDIANAPOLIS NORTH CAROLINA SALT LAKE CITY 1001 COLLEGE AVENUE CLARKSVILLE AR 72830 PHONE 479 754 9108 FAX 479 754 9205 5525 W MINNESOTA STREET INDIANAPOLIS IN 46241 PHONE 317 246 5100 FAX 317 246 5110 CALIFORNIA IOWA LOS ANGELES DES MOINES 6480 FLOTILLA STREET 1800 DIXON STREET SUITE C COMMERCE CA 90040 PHONE 323 724 6771 FAX 323 721 5859 DES MOINES lA 50316 PHONE 515 263 6929 FAX 515 263 6515 HAYWARD MARYLAND 21056 FORBES AVENUE BALTIMORE HAYWARD CA 94545 6660 SANTA BARBARA RD PHONE 510 785 9900 SUITES 22 24 FAX 510 785 9910 ELKRIDGE MD 21075 PHONE 410 579 2135 COLORADO FAX 410 579 2677 DENVER 3855 FOREST STREET MASSACHUSETTS DENVER CO 80207 BOSTON PHONE 303 623 0127 6 PULLMAN STREET FAX 303 595 3772 WORCESTER MA 01606 PHONE 508 854 0708 CONNECTICUT FAX 508 854 0291 WALLINGFORD 65 SOUTH TURNPIKE ROAD MICHIGAN WALLINGFORD CT 06492 DETROIT PHONE 203 269 1354 FAX 203 269 5485 5993 PROGRESS DRIVE STERLING HEIGHTS MI 48312 PHONE 586 978 9800 FLORIDA FAX 586 978 9969 TAMPA PUERTO RICO VIRGIN ISLANDS MINNESOTA 3906 EAST 11TH AVENUE MINNEAPOLIS TAMPA FL 33605 PHONE 813 248 5078 FAX 813 247 2984 21080 134TH AVENUE NORTH ROGERS MN 55374 PHONE 763 428 3633 FAX 763 428 4551 GEORGIA ATLANTA MISSOURI 62 TECHNOLOGY DRIVE ST LOUIS 422 INDUSTRIAL DRIVE MARYLAND HEIGHTS MO 63043 PHONE
37. 1 Phase 240V 50 60 Hz 1 Phase With Inte 0 4 0 5 2 3A G6MDAN 2P3112 B gral EMC Filter 240V 50 60Hz 0 4 0 5 23A xk GMDAN 2P3102 B e 075 1 50A GMDAN 5P0102 B 0 4 0 5 23A G6MDBN 2P3102 B eae 15 2 8 04 G6MDBN 8P0102 B 3 Phase No Fitter 37 5 17 54 x G6MDBN 017102 B 55 75 24 0A G6MDBN 024102 C 480V 0 75 1 23A xk 6MDDN 2P3102 B 50 60 Hz 1 5 2 4 0A 6MDDN 4P0102 B 3 Phase No Filter 5 5 7 5 12 04 6MDDN 012102 C 600V 2 2 3 4 2A GMDEN 4P2102 B 50 60 Hz 7 5 10 12 2A 6MDEN 012102 C 3 Phase No Filter 11 2 15 19 0A G6MDEN 019102 C Instruction Manual MD65 User Manual MD65 Data Sheet MD65 Brochure Service Conditions Altitude Ambient Temperature Storage Temperature Relative Humidity Speed Regulation Intermittent Overload D2 3519 RAPS 960 RAPS 959 1 000 m 3 300 ft Maximum IP20 10 C 14 F to 50 C 122 F NEMA 1 IP30 10 C 14 F to 40 C 104 F 40 C 40 F to 85 C 185 F 0 to 95 non condensing V Hz 2 of base speed across a 40 1 speed range SE 1 of base speed across a 60 1 speed range 150 overload capacity for up to 1 minute 200 overload capacity for up to 3 seconds MD65 Kit Instruction Manuals Nema 1 Kit Input EMI Filters Installation Instructions MDCOMM 232 Serial Converter Module V S Utilities Software OIM User Guide OIM Quick Reference Remote Large OIM Installation Instructions Remote Small OIM Installation Instructions Door Mount NEMA 1
38. 105 18 5 25 15 20 26 7 64 2 698 080xx 4 80 105 140 22 30 18 5 25 30 5 73 2 876 104xx 5 104 115 175 30 40 22 30 40 6 98 967 130xx 5 130 143 175 37 50 30 40 50 7 122 1270 154xx 6 154 169 231 45 60 37 50 60 1 145 1496 192xx 6 192 211 288 55 75 45 60 74 9 180 1993 260xx 6 260 286 390 66 100 55 75 96 6 233 2255 480 VAC Output Amps 110 OL Duty Nominal Power Ratings Application Data 110 OL Duty 150 OL Duty Model Number 480 VAC Variable Torque Constant Torque Input KVA Input Amps pra Applications Applications 480 VAC 480 VAC 5480 VAC 1P1xx 0 11 12 1 6 0 37 0 5 0 25 0 33 0 7 0 9 53 2P1xx 0 2 1 2 4 3 2 0 75 1 0 55 0 75 1 4 1 6 63 3P4xx 0 3 4 45 6 1 5 2 1 1 1 5 2 2 2 6 76 5POxx 0 5 5 5 7 5 2 2 3 1 5 2 3 2 3 9 93 8POxx 0 8 8 8 12 4 5 2 2 3 5 7 6 9 164 011xx 0 11 12 1 16 5 5 5 T5 4 5 7 9 9 5 194 014xx 1 14 16 5 22 15 10 5 5 75 10 4 12 5 218 022xx 1 22 24 2 33 11 15 7 5 10 16 6 19 9 326 027xx 2 27 33 44 15 20 11 15 20 6 24 8 394 6V41 034xx 2 34 40 5 54 18 5 25 15 20 25 9 31 2 441 040xx 3 40 51 68 22 30 18 5 25 30 5 36 7 459 052xx 3 52 60 80 30 40 22 30 39 7 47 7 610 065xx 3 65 78 104 37 50 30 40 49 6 59 6 717 077xx 4 17 85 116 45 60 37 50 60 1 72 3 930 096xx 5 96 106 144 55 75 45 60 74 9 90 1 1107 125xx 5 125 138 163 55 100 45 75 97 6 117 1479 156xx 6 156 172 234 93 125 75 100 122 147 1845 180xx 6 180 198 270 110 150 100 125 141 169 2204 248xx 6 248 273 372 132 200 110 150 194 233 2512 30 BALDOR RELIANC
39. 13FK0150 VS50D 1 135 20 913FK0200 VS50D 1 210 25 913FK0200 VS50D 1 210 40 913FK0400 VS50D 1 240 75 913FK0750 VS50D 1 850 100 913FK1000 VS50D 2 000 125 913FK1000 VS50D 2 200 150 913FK1500 VS50D 2 640 200 913FK2000 VS50D 4 900 250 913FK2500 VS50D 5 000 300 913FK3000 VS50D 5 000 400 913FK4000 VS50D 2 800 b 500 913FK5000 VS50D 3 000 600 913FK6000 VS50D 3 200 b a Includes D B contactor and D B resistors Customer must supply fuses and 115 VAC power for contactor b Kit consists of resistors and enclosure only Drive has DB pole on contactor as standard c This kit cannot be used with FlexPak 3000 Power Module drives Contact your local BaldoreReliance sales office for assistance 58 FLEXPAK 3000 DC Drives BALDOR RELIANCEF FlexPak 3000 Drive Options Inverting Fault Circuit Breaker This modification replaces the standard inverting fault fuse The inverting fault circuit breaker is recommended when applying regenerative FlexPak 3000 drives to high inertia loads where the reflected load WR2 to the motor is equal to or greater than the motor s It also is used on applications where the drive is frequently in a low power regenerative mode such as on un winders and pay offs The inverting fault breaker must be mounted separately from the drive unless the drive is mounted in a cabinet HP Rating HP Rating Kit Mult Kit 240 VDC 500 VDC Catalog Number Sym List Price 1 1 2 2 3 5 906FK0101 VS50D 775
40. 3 5 7 5 10 906FK0201 VS50D 775 7 1 2 10 15 20 906FK0301 VS50D 775 15 20 25 40 906FK0401 VS50D 900 25 30 50 60 906FK0501 VS50D 950 75 150 906FK1201 VS50D 2 350 100 150 200 300 Standard on FB model drives a Included in drive price and must be specified with regenerative 400 600 Hp drives Line Filter Kit The Line Filter kit is used on 400 600 Hp FlexPak 3000 drives when the primary of the drive s source transformer is greater than 2300 VRMS The kit helps attenuate high voltage spikes that capacitively couple from the transformer primary to secondary Hp Kit Catalog Number Mult Sym List Price 400 600 918FK0601 VS50D 750 59 BAILDOR RELIANCER FLEXPAK 3000 DC Drives FlexPak 3000 Drive Options NEMA 1 Conversion Kit This modification allows conversion of standard chassis to NEMA 1 enclosure This kit cannot be used with FlexPak 3000 Power Module drives HP Rating HP Rating Kit Mult Kit 230 VAC 460 VAC Catalog Number Sym List Price 40 75 75 150 904FK0201 VS50D 1 100 100 150 200 300 N A NA N A 400 600 N A N A N A Dimensions Hp Rating Hp Rating Width Height Attached Depth 230VAC 460VAC Inches mm Inches mm Inches mm 40 75 75 150 18 9 480 37 8 959 6 13 1 332 8 eg 8 9 480mm I 8 b 37 8 sm ES ES es E 8 8 28 2 _ 715 9mm
41. 314 298 1800 FAX 314 298 7660 ALPHARETTA GA 30005 PHONE 770 772 7000 FAX 770 772 7200 ILLINOIS CHICAGO 340 REMINGTON BLVD BOLINGBROOK IL 60440 PHONE 630 296 1400 FAX 630 226 9420 KANSAS CITY 1501 BEDFORD AVENUE NORTH KANSAS CITY MO 64116 PHONE 816 587 0272 FAX 816 587 3735 Baldor Electric Company CA701 GREENSBORO 1220 ROTHERWOOD ROAD GREENSBORO NC 27406 PHONE 336 272 6104 FAX 336 273 6628 OHIO CINCINNATI 2929 CRESCENTVILLE ROAD WEST CHESTER OH 45069 PHONE 513 771 2600 FAX 513 772 2219 CLEVELAND 8929 FREEWAY DRIVE MACEDONIA OH 44056 PHONE 330 468 4777 FAX 330 468 4778 OKLAHOMA TULSA 7170 S BRADEN SUITE 140 TULSA OK 74136 PHONE 918 366 9320 FAX 918 366 9338 OREGON PORTLAND 20393 SW AVERY COURT TUALATIN OR 97062 PHONE 503 691 9010 FAX 503 691 9012 PENNSYLVANIA PHILADELPHIA 1035 THOMAS BUSCH MEMORIAL HIGHWAY PENNSAUKEN NJ 08110 PHONE 856 661 1442 FAX 856 663 6363 PITTSBURGH 159 PROMINENCE DRIVE NEW KENSINGTON PA 15068 PHONE 724 889 0092 FAX 724 889 0094 TENNESSEE MEMPHIS 4000 WINCHESTER ROAD MEMPHIS TN 38118 PHONE 901 365 2020 FAX 901 365 3914 2230 SOUTH MAIN STREET SALT LAKE CITY UT 84115 PHONE 801 832 0127 FAX 801 832 8911 WISCONSIN MILWAUKEE 1960 SOUTH CALHOUN ROAD NEW BERLIN WI 53151 PHONE 262 784 5940 FAX 262 784 1215 INTERNATIONAL SALES FORT SMITH AR P O BOX 2400 FORT SMITH AR 72902 PHONE 479 646 4711 FAX 479
42. 38 04235 AX 886 4 238 04463 UNITED KINGDOM 6 BRISTOL DISTRIBUTION PARK HAWKLEY DRIVE BRISTOL BS32 OBF U K PHONE 44 1454 850000 FAX 44 1454 859001 VENEZUELA AV ROMA QTA EL MILAGRO URB CALIFORNIA NORTE CARACAS 1070 VENEZUELA PHONE FAX 58 212 272 7343 MOBILE 58 414 114 8623 Printed in U S A 10 10 TCP 5000
43. 41 VS50D 30 090 500 680 800 15 500FR4041 VS50D 30 600 600 816 960 15 600FR4041 VS50D 31 110 Dimensions Weight Ibs kg 450 204 5 Catalog Number Height Depth Inches mm Inches mm All 460 VAC catalog numbers 400 through 600 Hp 26 68 677 7 42 25 1149 2 18 82 478 1 NOTE a An inverting fault circuit breaker Model Number 906FK3101 must be specified with 400 600 Hp regenerative drives and is included in Drive price Refer to OPTIONS section for description NOTE Option kits may add additional mounting depth Please allow adequate clearance when option kits are mounted on the drive package 54 BALDOR RELIANCEE FlexPak 3000 Digital DC Drives Special AC Line Voltage Drives w FLEXPAK 3000 DC Drives For 380 VAC or 415 VAC input select the required armature amps to price the drive Hp and kW ratings are estimated and should only be used as an approximation Special 380 415 VAC Non Regenerative FlexPak 3000 380 VAC 415 VAC 460 VAC 400 VDC Armature 460 VDC Armature 500 VDC Armature DC DC Catalog Mult List 250 VDC Field 270 VDC Field 300 VDC Field AC Amps seg Have Number Sym Price mps mps Hp kW Hp kW Hp kW l i 2 4 1 8 2 8 2 1 3 2 2 10 7 10 7FN3042 VS50D 4 380 12 9 13 8 10 3 15 11 2 26 29 10 29FN3042 VS50D 4 550 a Hp and KW ratings are estimated b Requires use of nonstandard voltage DC motors Contact Baldor Reliance sales office for motor pricing assi
44. 6 10 NA A Note 1 Always check resistor ohms against minimum resistance for drive being used Note 2 Duty cycle listed is based on full speed to zero speed deceleration For constant regen at full speed duty cycle capability is half of what is listed Application Type 1 represents maximum capability up to 100 braking torque where possible Application Type 2 represents more than 100 braking torque where possible up to a maximum of 150 Note 3 For 11 and 15 kW 15 and 20 HP normal duty external resistor applications use two 7 5 kW 10 HP size resistors wired in parallel Note 4 The minimum resistance specification is applicable to a customer supplied external braking resistors DISCOUNT VS 1AC 12 BALDOR RELIANCEF SP600 AC Drives A full featured industrial AC drive suitable UD for panel machine flange and washdown CE Cu mounted installations SP600 Drives from 0 5 to 50 HP 6SP Series SP600 Drives from 20 to 200 HP 6SB Series The benchmark for value in AC Drives the SP600 provides the benefits of more expensive full featured drives in a compact versa tile and cost effective design Multiple enclosure packaging options with drive mounted LCD keypad and embedded braking circuitry make this drive very versatile The wide range of network options available for this product will allow you to maximize data acquisition control and application flexibility STANDARD FEATURES Wall or Machine Mount NEMA 1
45. 70 81 108 782 931 124 185 25 15 20 Model Number 380 480 VAC Three Output Amps Nominal Power Ratings 110 OL 150 OL 480 VAC Input 400 VAC Input Duty Duty 1P1 11 13 14 0 37 0 5 0 25 0 33 2P1 2 24 32 21 24 32 075 1 0 55 0 75 3P4 34 45 6 35 45 6 1 5 2 11 15 005 5 55 75 5 55 75 22 3 15 2 008 8 88 12 87 99 132 4 5 3 3 011 11 121 165 115 13 174 55 75 4 5 6SP4xx 014 14 165 22 154 172 231 75 10 55 7 5 022 22 242 33 22 242 33 11 15 75 10 027 27 33 44 30 33 45 15 20 11 15 034 34 405 54 37 405 54 185 25 15 20 040 40 51 68 43 51 68 22 30 185 25 052 52 60 80 60 66 90 30 40 22 30 065 65 78 104 72 90 120 37 50 30 40 600 VAC Three phase Ratings Model Number Output Amps Nominal Power Ratings 575 600 VAC Input 110 OL Duty 150 OL Duty 0P9 09 1 4 037 0 5 0 25 0 33 1P7 17 2 26 0 75 1 05 0 75 2P7 27 36 48 15 2 1 15 3P9 39 43 58 22 3 15 2 6P1 61 67 91 4 5 2 3 9PO 9 99 135 55 75 375 5 6SP5xx 011 11 135 18 75 10 55 75 017 17 188 255 11 15 75 10 022 22 255 34 15 20 11 15 027 27 33 44 18 5 25 15 20 032 32 405 54 22 30 185 25 041 44 48 64 30 40 22 30 052 52 615 82 37 50 30 40 16 BALDOR RELIANCET 6SB Model 24 V 1 0 Terminal Assignments Control Terminals Terminal Defau
46. ARASHTRA INDIA PHONE 91 20 25 45 27 17 18 FAX 91 20 25 45 27 19 INDONESIA TALAVERA OFFICE PARK 28TH FLOOR SUITE M18 Jl T B SIMATUPANG KAV 22 26 JAKARTA 12430 INDONESIA PHONE 62 21 7599 9879 FAX 62 21 7599 9878 ITALY VIA SOTTOBISIO 30 BALERNA CH 6828 PHONE 41 91 683 6161 FAX 41 91 630 2633 BALDOR BALDOR ELECTRIC COMPANY World Headquarters P O Box 2400 Fort Smith AR 72902 2400 U S A h 479 646 4711 e Fax 479 648 5792 e International Fax 479 648 5895 e www baldor com BALDOR SALES OFFICES gt JAPAN DIA BLDG 802 2 21 1 TSURUYA CHO KANAGAWA KU YOKOHAMA 221 0835 JAPAN PHONE 81 45 412 4506 FAX 81 45 412 4507 MEXICO LEON GUANAJUATO KM 2 0 BLVD AEROPUERTO LE N 37545 GUANAJUATO M XICO PHONE 52 477 761 2030 FAX 52 477 761 2010 MIDDLE EAST amp NORTH AFRICA VSE INTERNATIONAL CORP P O BOX 5618 BUFFALO GROVE IL 60089 5618 PHONE 847 590 5547 FAX 847 590 5587 PANAMA AVE RICARDO J ALFARO EDIFICIO SUN TOWERS MALL PISO 2 LOCAL 55 CIUDAD DE PANAM PANAM PHONE 507 236 5155 FAX 507 236 0591 SINGAPORE 18 KAKI BUKIT ROAD 3 03 09 ENTREPRENEUR BUSINESS CENTRE SINGAPORE 415978 PHONE 65 6744 2572 FAX 65 6747 1708 SWITZERLAND POSTFACH 73 SCHUTZENSTRASSE 59 CH 8245 FEUERTHALEN SWITZERLAND PHONE 41 52 647 4700 FAX 41 52 659 2394 TAIWAN 1F NO 126 WENSHAN 3RD STREET NANTUN DISTRICT TAICHUNG CITY 408 TAIWAN R O C PHONE 886 4 2
47. CA701 Le gacy Effective Date October 2010 Reliance Drives BALDOR ntent BALDOR RELIANCEF Contents TABLE OF CONTENTS Series 6 Drives MD60 AC Drives O PEU PO nn eo eae 1 MOD AC DINGS exo eden woe Lee tania as de rs ERS 6 SPOOOAG DIVES carrier ada a ada 13 GV6000 AC A a ee or on 26 Legacy Reliance Drives SP500 AG DIVES Ses tre darla aa Bee A horse 34 GV3000 AC DINGS n nannu uneer raana seins s 37 DOSIS rca e ia di De 47 FlexPak a eee 51 BALDOR RELIANCET For applications from 0 25 to 5 HP the MD60 is a simple AC Microdrive that can be panel mounted as well as wall or machine mounted Reliance Electric s MD60 AC Drive is ready to operate out of the box The drive includes a built in LED display and operator controls including a single turn potentiometer for speed reference Built in dynamic braking UL circuitry only requires the addition of a braking resistor to meet higher performance application needs to handle fast accel amp decel rates PRICE PRACTICALITY amp PERFORMANCE This is the criteria that drove the development of the MD60 AC Drive This product offering is targeted at the fastest changing and growing segment of the variable speed drive market the market from fractional to five horsepower CONFIGURATION amp DISPLAYS The parameters of the MD60 are segregated into groups P Parameters which reflect the basic values required for operation and A Parameters which
48. CEF DC2 DC DRIVES DC3R Regenerative DC Drives 1 4 1Hp 115 VAC 1 Ph 50 60 Hz 90 VDC Armature 1 2 2Hp 230 VAC 1 Ph 50 60 Hz 180 VDC Armature Hp Ratin Non Isolated Controller selection DC3R Chassis model 115 230 VAC 1 Phase 50 60 Hz P g Catalog Numb For the operation of Permanent Magnet and Shunt wound DC Motors al atalog Number 115 VAC 230 VAC s Chassis Rated AC DC Armature Rated Armature Motor Field List Mult BC Series Input Input Type Line Amps Voltage Current Amps Voltage Price Sym Alternate a Hp Rating Catalog Number Isolated Controller selection DC3R Chassis model 115 230 VAC 1 Phase 50 60 Hz 1 4t01 2 Plate 4 2 to 7 5 90 2 7 to 5 0 50 100 BC204 BC215 BC143 b 1 2t010 Plate 7 5 to 12 1 90 5 0 to 10 50 100 L 222 DC3R 12D 00 010 Al 521 vsapc 0r order as BC204 BPSI c 1 2t01 0 Plate 3 8 to 6 7 180 2 5 to 5 0 100 200 with BC215 Bi polar Signal 10t020 Plate 6 7t011 7 180 5 0 to 9 2 100 200 Isolator NOTE Requires addition of Heatsink Kit Option DC3R HS 00 List Price 149 00 Drive instruction manual D2 3453 DCSR Isolation Board Option instruction manual D2 3454 a Review dimensions and application I O functionality for complete compatibility Contact your local district office for assistance b BC143 Heatsink option required for 1 Hp 115 VAC or 2 Hp VAC rating c Catalog number indicates option kits
49. EP GV6000 AC Drives WALL MACHINE PANEL MOUNT DRIVES e Motor Power Rating 0 5 to 100 HP 0 33 to 75 kW Input Voltage 200 208 240 VAC 50 60 Hz Enclosure NEMA 1 Ventilated IP20 e Mounting Wall Machine Panel Mount as IP20 200 240 VAC 50 60 Hz Input Ratings 0 5 to 100 HP Horsepower Rating Drive Amps 240 V 3 NEMA 1 1P20 110 OL 150 OL 1 E Model Number WT CT a List Applications Applications 6V21 080TA 5 751 6V21 260NA 18 673 1 Overload of 150 of rated current for 1 minute dependent on actual motor full load amps versus drive continuous amp rating 2 Rated for 240 VAC input and 4 kHz switching frequency 260 Amp Unit 2kHz 3 See amp rating chart for currents 208 VAC e Motor Power Rating 0 5 to 200 HP 0 33 to 150 kW e Standard LCD OIM Keypad Included e Input Voltage 380 400 415 amp 480 VAC 50 60 Hz e Encoder Feedback Included e Enclosure NEMA 1 Ventilated IP20 e Zero clearance side by side mounting e Mounting Wall Machine Panel Mount as IP20 380 480 VAC 50 60 Hz Input Ratings 0 5 to 200 HP 200 HP Horsepower Rating Drive Amps 480 V 3 NEMA 1 1P20 110 OL 150 OL 1 Model Number eae Continuous 2 List Applications Applications 0 5 3 2 6V41 1P1TA 0 X inc 0 33 1 1 1 2 1 6 1 711 6V41 5POTA 0 X inc 5 5 5 7 5 1 711 6V41 011TA 0 X inc 7 5 5 11 12 1 16 5 2 205 6V41 027TA 2 x inc 20 15 27 33 44 3 536 6V41 065TA 3 X inc 50
50. IP20 e Typical OIM Operator Functions The SP600 AC drive offers versatility and simple Wall or Machine Mount NEMA 4X 12 Start Stop intelligence setting the standard by which drives IP66 Forward Reverse in this class are measured Flange Mount NEMA 1 IP20 Jog Zero clearance stacking side by side Auto Manual For customers who rely on the simplicity of cabinet mounting with 50 C rating IP20 the SP500 the SP600 provides the user gt Switching Frequency Clear Fault friendliness expected by our customers with the 3 advanced features and functionality of a leading 4 10 kHz carrier frequency Other Features edge drive Increase up to 10 kHz for quiet motor e Configuration and monitoring of single or o operation See manual for de rating multiple drives when using optional V S The default configuration of the SP600 limits the e Detachable Operator Interface Utilities PC Software customer s exposure to a Basic access level of Multi line 6 language LCD OIM for local or Intelligent Thermal Management ITM parameters remote operation Allows drive configuration system can reduce carrier frequency or shut But for those who require broader application E es de dl in case of an over temperature flexibility the full access level of parameters gives the user complete access to all of the drive 24 V Digital Inputs qty 6 configurable e UL and NEC approved electronic motor parameters e 8 programmable pre set speed
51. OIM Bezel Kit Cable Accessory Kits DB Resistor Kits Communication Cover Kit NEMA 1 Kit w Comm Card DeviceNet Comm Card EtherNet Comm Card Profibus Comm Card D2 3503 D2 3504 D2 3502 D2 3488 D2 3534 D2 3508 D2 3509 D2 3526 D2 3517 RA INOO3A EN P RA INOO4A EN P D2 3523 D2 3527 D2 3520 D2 3529 D2 3530 BALDOR RELIANCEF PA Drives MOUNTING DIMENSIONS Dimensions are in millimeters and inches Weights are in kilograms and pounds Front View Frame A 60 D LEO Wen B 100 213 136 87 180 87 4 168 2 2 3 94 839 5 35 343 7 09 344 661 49 c 130 320 180 116 260 3 246 4 3 51 12 6 7 1 4 57 10 2 9 7 9 5 1 Height Dimension includes NEMA 1 IP30 kit 2 Height Dimension for standard IP20 unit without NEMA 1 1P30 kit 3 C Frame Enclosure does not support a din rail mounting and the F dimension does not apply 6MD V N 2P3 1 1 2 6MD MD Drive 1 MD60 2 MD65 NEMA 1 1P30 Kit A 1 Phase 240 VAC 0 No Filter V 1 Phase 115 VAC 1 Internal Filter B 3 Phase 230 VAC D 3 Phase 460 VAC E 3 Phase 575 VAC N IP20 Open Reserved 115V 230 VAC 2P3 2 3A 0 5 HP 5P0 5 0A 1 HP 6P0 6 0 A 1 5 HP 8P0 8 2 HP 012 12 A 3 HP 017 17 5 A 5 HP 024 24 A 7 5 HP 033 33 A 10 HP FRAME B Side View FRAME C Bottom View Bottom View 460 VAC 1P4 1 4 0 5 HP 2P3 2 3 1 HP 4P0
52. Panel mount zero clearance stackable e Models available with LCD OIM keypad e Models available with 24 VDC or 120 VAC 1 0 380 480 VAC 50 60 Hz Input Rating 20 to 200 HP Horsepower Rating Drive Amps 480 V NEMA 1 1P20 P et 110 OL 150 OL x A Model Number With Brake With Filter VT CT gontinu 1 Min 3 Sec List a ee ous Applications Applications 065CTANA 3 50 40 65 78 104 7 628 077CNANA 4 60 50 77 97 5 130 8 388 156CNANA 12 641 6SB401 156CTANA 6 125 100 156 172 234 13 468 180CNANA 6 150 125 180 198 270 13 692 248CNANA 6 200 150 248 273 372 19 068 1 Overload of 150 of rated current for 1 minute dependant on actual motor full load amps versus drive continuous amp rating 2 Rated for 480 VAC input and 4 kHz switching frequency 248 Amp Model 2KHz Switching Frequency 3 See amp rating chart for currents 400 VAC Model Numbers 6SB401 xxxBTANA are 24VDC Inputs without OIM OIM option available See page D 40 for information Model Numbers 6SB401 xxxCTANA are 24VDC Inputs with OIM Model Numbers for 115 VAC Inputs are non stock Consult factory WALL MOUNT Drives SP MODELS UL e Motor Power Rating 0 5 to 50 HP 0 33 to 37 kW e Input Voltage 575 600 VAC 50 60 Hz e Enclosure NEMA 1 Ventilated IP20 e Mounting Wall Machine Panel Mount as IP20 e Models available with LCD OIM keypad e Zero clearance side by side mounting y
53. Preset Frequency 1 0 0 Hz A072 Preset Frequency 2 0 0 Hz A073 Preset Frequency 3 0 0 Hz A078 Jog Frequency 10 0 Hz A079 Jog Accel Decel 10 0 sec A080 DC Brake Time 0 0 sec A081 DC Brake Level Amps x 0 5 A082 DB Resistor Select 0 Disabled A083 S Curve 0 Disabled A084 Start Boost 8 5 0 A088 Maximum Voltage Rated Volts A089 Current Limi Amps x 1 8 A090 Motor OL Select 0 No Derate A091 PWM Frequency 4 0 kHz A092 Auto Restart Tries 0 A093 Auto Restart Delay 1 0 sec A094 Start At Power Up 0 Disabled A095 Reverse Disable 0 Reverse Enabled A096 Flying Start Enable 0 Disabled A097 Compensation 1 Electrical A098 SW Current Trip 0 0 Disabled A099 Process Factor Display Scaling 30 A100 Fault Clear 0 Ready A101 Program Lock 0 Unlocked A102 Testpoint Select 0 A103 Comm Data Rate 4 19 2K A104 Comm Node Address 1 A105 Comm Loss Action 0 Fault A106 Comm Loss Time 5 A107 Comm Forma 0 RTU 8 N 1 A110 0 10 V Analog Input Low 0 00 A111 0 10 V Analog Input High 100 00 A112 4 20 mA Analog Input Low 0 00 A113 4 20 mA Analog Input High 100 00 A114 Slip Compensation 2 0 Hz A115 Process Time Lo 0 A116 Process Time Hi 0 2 Parameters within this group are accessed without any password required The parameters are presented this way for identification purposes only to help simplify setup Display Parameters d001 Output Frequency d012 Control Source d002 Command Frequency d013 Control Input Status d003 Output
54. Rated z Full Load RMS Rated Field Catalog Mult List Hp Rating AC Line Current DE Armar Current Number Sym Price Current 100 307 360 15 200FB4042 VS50D 19 100 150 443 521 15 300FB4042 VS50D 20 300 Dimensions Shown for 460 VAC Models Height Depth Weight Catalog Number NE Inches mm Inches mm Ibs kg All 230 VAC drives 100 through 150 Hp All 460 VAC catalog numbers 23 6 599 33 5 850 16 7 424 7 220 5 100 0 200 through 300 Hp NOTE Option kits may add additional mounting depth Please allow adequate clearance when option kits are mounted on the drive package 52 BALDOR RELIANCEr FLEXPAK 3000 DC Drives FlexPak 3000 Digital DC Drives 460 VAC 50 60 Hz Non Regenerative 3 Hp 60 Hp Full Load Rated E Full Load RMS Rated Field Catalog Mult List Hp Rating AC Line Current DE Armature Current Number Sym Price Current 3 10 6 10 3FN4042 VS50D 3 870 10 18 19 10 10FN4042 VS50D 3 885 460 VAC 50 60 Hz Regenerative 3 Hp 60 Hp 500 VDC Armature 300 VDC Field Full Load Rated is Hp Rating Full Load RMS DC Armature Rated Field Catalog Mult List AC Line Current Current Number Sym Price Current 3 10 6 10 3FR4042 VS50D 4 380 Dimensions Height Depth Weight senos a ae Inches mm Inches mm Ibs kg All 460 VAC catalog numbers 10 65 270 5 18 79 477 3 12 23 310 6 58 26 4 3 through 60 Hp 460 VAC 50 60 Hz Non regenerative 75 Hp 150 Hp 500 VDC Armature 300
55. VDC Field Full Load Rated a Full Load RMS Rated Field Catalog Mult List Hp Rating AC Line Current jus Current Number Sym Price 125 177 207 15 125FN4042 VS50D 7 140 Dimensions Height Depth Weight Catalog Number fee Inches mm Inches mm Ibs kg All 460 VAC catalog numbers 75 through 150 Hp 18 11 460 19 29 490 13 46 341 9 122 55 53 BALDOR RELIANCEF FLEXPAK 3000 DC Drives FlexPak 3000 Digital DC Drives 460 VAC 50 60 Hz Regenerative 75 Hp 150 Hp 500 VDC Armature 300 VDC Field Full Load Rated Full Load RMS Rated Field Catalog Mult List Hp Rating AC Line Current ei Current Number Sym Price 200 281 330 15 200FB4042 VS50D 19 100 300 421 495 15 300FB4042 VS50D 20 300 Dimensions Weight Ibs kg 220 5 100 Catalog Number All 460 VAC catalog numbers 200 through 300 Hp Height Depth Inches mm Inches mm 23 6 599 33 5 850 16 7 424 7 460 VAC 50 60 Hz Non Regenerative 400 Hp 600 Hp 500 VDC Armature 300 VDC Field Full Load Rated Full Load RMS Rated Field Drive Mult List Hp Rating AC Line Current i Current Catalog Number Sym Price 400 567 667 15 400FN4041 VS50D 460 VAC 50 60 Hz Regenerative 400 Hp 600 Hp 500 VDC Armature 300 VDC Field Full Load Rated z Full Load RMS Rated Field Drive Mult List Hp Rating AC Line Current DE Armature Current Catalog Number a Sym Price Current 400 567 640 15 400FR40
56. actices for drives and motors as identified in the MD65 User Manual MD65 EMC Filters Description Model Number List External EMC Filter for Short Cable Distances MD65 EMC filter 5 meter 7 5 10 HP 230 V 3 ph 6MDF 034CS 113 MD65 EMC filter 5 meter 7 5 10 HP 460 V 3 ph 6MDF 018CS 102 External EMC Filter for Long Cable Distances MD65 EMC filter 100 meter 3 HP 230 V 1 ph 6MDF 025CL 113 MD65 EMC filter 100 meter 1 2 5 HP 230 V 3 ph 6MDF 021BL 113 MD65 EMC filter 100 meter 7 5 10 HP 230 V 3 ph 6MDF 034CL 147 Note The 230 V single phase input drives are available with a factory installed filter option and may not need to have the external filters listed above installed to meet the required emission standards Contact Reliance or reference the User Manual D2 3519 for details V S Utilities Configuration Software The MD65 drive can be configured using the V S Utilities software The V S Utilities software kit includes the standard Reliance PC software All necessary cables and the serial converter are included in the MD65 Serial Converter Kit Reference the D2 3502 Serial Converter Module Instruction Manual for details V S Utilities Software and Cables Description Model Number List VS Utilities software CD RECOMM VSUTIL 154 RJ45 to RJ45 2 meter male to male cable MD60 MD65 to converter MDCBL RJ45 13 Serial converter to computer cable RECBL SFC 57 MD65 AC Drives DB Resistor Kits
57. age based on the power rating of the MD60 Also refer to the MD60 User Manual for connections and parameter setup when using braking resistors Drive Rating Nominal Value Resistor z Model List HP Rating W number 1 Price 230 V DB Resistor 1 91 500 2 91 500 AK R2 091P500 203 3 47 500 5 47 500 AK R2 047P500 203 1 Resistors listed in this table are rated for a 5 duty cycle V S Utilities Configuration Software The MD60 drive can be configured using the V S Utilities software The V S Utilities software kit includes the standard Reliance PC software All necessary cables and the serial converter are included in the MD60 Serial Converter Kit Reference the D2 3502 Serial Converter Module Instruction Manual for details V S Utilities Software and Cables Description Model Number List VS Utilities software CD RECOMM VSUTIL 154 RJ45 to RJ45 2 meter male to male cable MD60 MD65 to converter MDCBLRJ45 bd Serial converter to computer cable RECBL SFC 57 MD60 MD65 Cable Accessories The MD60 drive provides an RJ45 port to allow the connection of a single peripheral device The RJ45 Splitter Cable can be used to connect a second MDI peripheral device to the drive MD60 MD65 Cable Accessories Description Model Number List RJ45 to RJ5 2 meter male to male Cable MD60 MD65 converter MDCBL RJ45 15 OIM Cable 2 9 meter OIM to RJ45 MDCBL CC3 34 MDI Splitter Cable AK U0 RJ45 SC1 17
58. ak Power kW pania ll Normal Duty kW 10 Tolerance During On Time motor torque 240V 0 5HP 0 37 34 131 1 08 293 240V 1HP 0 75 34 66 2 15 287 240V 2HP 1 5 34 61 2 33 155 240V 3HP 2 2 34 49 2 89 132 240V 5HP 4 31 33 4 3 107 240V 7 5HP 5 5 23 24 5 91 107 240V 10HP 15 23 24 5 91 79 480V 0 5HP 0 37 68 502 1 13 305 480V 1HP 0 75 68 306 1 85 247 480V 2HP 1 5 68 163 3 48 232 480V 3HP 2 2 68 131 4 33 197 480V 5HP 4 68 97 5 85 146 480V 7 5HP 55 74 70 8 11 147 480V 10HP 75 74 73 7 17 104 480V 15HP 11 44 45 12 61 115 480V 20HP 15 31 44 45 12 61 84 480V 25HP 18 5 32 32 17 73 96 480V 30HP 22 27 27 21 01 96 480V 40HP 30 20 20 28 37 95 480V 50HP 37 21 21 27 02 73 480V 60HP 45 17 17 33 37 74 480V 75HP 55 11 11 51 58 94 480V 100HP 75 11 11 51 58 69 480V 125HP 90 9 9 63 04 70 480V 150HP 110 T 7 81 05 74 480V 200HP 132 3 3 4 141 84 107 600V 0 5HP 0 37 117 874 1 01 274 600V 1HP 0 75 117 471 1 88 251 600V 2HP 1 5 117 255 3 48 232 600V 3HP 2 2 117 209 4 24 193 600V 5HP 4 81 120 7 39 185 600V 7 5HP 55 81 82 10 81 197 600V 10HP 7 5 81 82 10 81 144 600V 15HP 11 48 48 18 47 168 600V 20HP 15 48 48 18 47 123 31 ohms for 6SP models and 44 ohms for 6SB models 24 BALDOR RELIANCEF SP600 AC Drives Modified Standard NEMA 4X 12 Wall Mount Drives with Disconnect 1 e Motor Power Rating 0 5 to 20 HP 0 33 to 15 kW e Input Voltage 230 480 VAC 50 60 Hz e Operator Funct
59. ctable 2KHz 4KHz Standard or 8KHz Frequency Setting 10 VDC 0 10 VDC 4 20 mA or 0 20 mA digital keypad Serial Communications via option RS 232 via CS3000 Software Accel Decel 0 999 9 seconds otor Matching Automatic tuning to motor with manual override PC Setup Software CS3000 Software available using the RS 232 port for commissioning parameter viewer scope capture and cloning aximum Output Frequency 200 Hz Feedback Type Incremental encoder coupled to motor shaft Pulses Rev 512 PPR 1024 PPR Standard 2048 PPR 4096 PPR SE No encoder sensorless vector operation nput Type 2 channel in quadrature 15 VDC differential Power Supply for Encoder 15 VDC 250 mA maximum ax Frequency ne Differential 125 KHz 10VDC 0 10VDC 4 20 mA or 0 20 mA 10 bit sign 50 kOhms Volt mode 250 Ohms Current mode Analog Inputs Analog Outputs Digital Inputs Relay Outputs nalog Outputs 1 Assignable 0 nput Impedance A ull Scale Range 0 10V or 4 20mA Source Current 1 mA maximum volt mode 20mA using external supply or 15V encoder supply Resolution 9 bits Quantity 3 Assignable 5 dedicated inputs Function Loss Run Jog Reset Stop Start Rated Voltage 24VDC Nominal Utilizing Internal 24VDC Isolated Power Supply Update Rate 75mSec 126mSec depending on input and whether V Hz or Vector mode Rated Voltage 250VAC 30VDC maximum aximum Curre
60. d 0 6 Amps 125 VAC for customer use Aux relay not available on BC Series Signal Isolation Option Boards c DC2 Series 50 Drive must be mounted to a metal surface 18 by 18 to meet 1hp 115 VAC and 2HP 230 VAC or an optional heat sink HS1 50 can be purchased d Switch reversing DC2 models include as standard an installed line fuse e Review dimensions and applications I O functionality for complete compatibility Contact your local district office for assistance f Catalog number indicates option kits factory installed for functional equivalent drive A transformer is mandatory for tachometer feedback operation using the Type RE 020 20 8 VDC 1000 RPM tachometer Model Number R20E8000 The Type RE 007 Model Number RO7E1210 fully isolated 7 VDC 1000 tachometer does not require an isolation transformer Consult Instruction Manual D2 3231 for other recommended and mandatory use of isolation transformers Mounting Dimensions Outside Mounting Drive Style Height Width Depth Height Width Inches mm Inches mm Inches mm Inches mm Inches mm Open Chassis DEZ Series d 7 875 200 4 875 125 7 375 188 5 0 128 47 BALDOR RELIANCEE DC3N Non Regenerative DC Drives 1 8 1Hp 115 VAC 1 Ph 50 60 Hz 90 VDC Armature 1 4 2Hp 230 VAC 1 Ph 50 60 Hz 180 VDC Armature Non Isolated Controller Selection DC3N Enclosed Models 115 230 VAC 1 Phase 50 60 Hz DC2 DC DRIVES
61. d option boards Encoder feedback is included at no additional cost on each drive A simple yet powerful keypad is supplied with every Reliance Electric GV6000 drive The semi graphic backlit LCD display provides an interface to the drive that is user friendly yet fully functional and includes our CopyCat function for transferring parameter sets between drives Diagnostics is a very important attribute of the Reliance Electric GV6000 product line A dedicated fault alarm key directs you to the fault and alarm queues which indicate a descriptive name a fault or alarm number for easy navigation in the extensive troubleshooting section of the manual and a time stamp that indicates the elapsed time since the event Dynamic braking is provided with an integral snubber 7th transistor standard on frame 0 4 drives Other optional features include a wide assortment of communications modules software utilities remote keypads and full numeric keypads Input Voltages Power Ratings e 200 208 240 0 5 to 100 HP e 380 400 415 480 0 5 to 200 HP e 600 1 to 150 HP Enclosures Mounting e Wall or Machine Mount NEMA 1 convertible to IP20 e Zero clearance stacking side by side cabinet mounting with 50 C rating Detachable Operator Interface e Every GV6000 comes standard with our easy to use Operator Interface Module OIM to provide metering programming and operator control The GV6000 follows the same TAB pro
62. ect the drive s DC bus to a matched resistor package for regulation of regenerative energy Model Number M3452H150B7 Snubber Transistor Kit These snubber transistor circuits are designed to be utilized in engineered applications Matching the appropriate resistor package then allows the user to optimize the braking capacity of the snubber based on peak and continuous loads Be sure to follow the minimum resistance values provided in the table Using resistances lower than the published data will result in excess current being allowed through the circuit and damaging the snubber transistor gt Snubber Max iek Model Amps List Number DC 230 2ST20019 No longer available see page 43 for alternate selections 2ST40009 No longer available see page 43 for alternate selections 2ST40125 Use M3452H150B7 M3452H150B7 150 5 Continuous Yes B7 4 272 460 M3452H200K6 200 3 8 Continuous Yes K6 4 748 25140300 Use M3452H300K6 M3452H300K6 300 2 5 Continuous Yes K6 5 126 M3452H600K6 600 1 25 60 Seconds Ues K6 6 606 1 See page D 64 for Cabinet Dimensions INSTRUCTION MANUAL D2 3291 Snubber Resistor Selection Information For use with the Snubber Transistor Kits Snubber Transistor Kits require a resistor for dissipation of regenerative energy as heat By selecting the proper resistor the user can optimize the braking performance of the drive system The following table provides resistor sizing in
63. es Communication Module Braking Resistor Kit CE amp C Tick External Mount EMC Compliance Filter Kits SP600 drives are designed to meet Global Industry Standards including those of Europe CE and Australia C Tick EMC compliance for both conducted and radiated noise emissions can be met by following the table below and adding the recommended filter as designated Also be sure to follow recommended wiring practices for drives and motors as identified in our product manuals as well as those of each region CE EMC Filters Model Number Description List 6SP MF1A 1 Phase 240 VAC 8A 146 6SP MF3A 3 Phase 200 460 VAC 5 156 SP600 Frame Filter External only see above Optional internal by model number Standard internal Standard internal Standard internal Standard internal Standard internal Standard internal Standard internal oa BIS N OJO Y gt DISCOUNT VS 1AC BALDOR RELIANCEF V S Utilities Configuration Software This windows based software package allows online configuration and monitoring of the SP600 AC drives This software utility allows the user to upload download monitor and compare parameter values in a user friendly environment VS Utilities runs under Windows 98 NT ME 2000 XP V S Utilities Features e Custom views for monitoring selected parameters e Compare drive parameter settings to Defaults Saved files e Point to point or multi drop capabilities
64. etwork Connection Diagram Bottom Vlew Side View Bottom Vlew Frame B Frame C DISCOUNT VS 1AC 11 BALDOR RELIANCEF don OS MD60 amp 65 Dynamic Brake Resistor Specifications The following dynamic brake resistors for use with the MD60 amp MD65 product lines are designed for 100 braking torque at a 5 duty cycle with a maximum on time of 10 seconds Resistors come standard with flying leads for ease of wiring while maintaining IP20 electrical finger safe requirements Connection points are provided for user supplied thermostat over temperature protection Application Cross Reference Minimum Max Application Application Drive and Resistance Resistance Continuous Brakin Type 1 Type 2 Duty Motor Size See Note 4 Part Number Ohms g Braking Braking Cycle Torque of Motor Torque Torque of Motor of Motor kW HP 5 100 120 Volt AC Input Drives 0 75 1 60 48 AK R2 091P500 91 0 00 17 218 100 23 150 31 1 1 1 5 60 48 AK R2 091P500 91 0 00 17 164 100 16 148 11 200 240 Volt AC Input Drives 0 37 0 5 60 48 AK R2 091P500 91 0 00 17 293 100 46 150 31 0 75 1 60 48 AK R2 091P500 91 0 00 17 218 100 23 150 15 1 5 2 60 48 AK R2 091P500 91 0 00 17 109 100 11 109 11 2 2 3 48 32 AK R2 047P500 47 0 16 33 144 100 15 144 11 4 5 32 19 AK R2 047P500 47 0 16 33 79 79 11 N A A 5 5 7 5 13 AK R2 030P1K2 30 0 26 52 90 90 10 NA A 7 5 10 10 AK R2 030P1K2 30 0 26 52 66 6
65. factory installed for functional equivalence DC3R Non isolated and isolated Plate Style Overall Dimensions Style Height Width Length Inches mm Inches mm Inches mm Non isolated 1 86 47 4 75 120 8 90 226 Isolated 3 12 78 4 75 120 8 90 226 Heatsink DC3R HS 00 1 0 25 6 9 175 9 78 248 49 BALDOR RELIANCEF FLEXPAK 3000 DC Drives FlexPak 3000 Applications Three phase DC drive for regenerative and non regenerative Digital DC Drives industrial applications from 1 1 2 to 600 Hp Features Flexible design allows for adaptability and use in many demand ing applications The Operator Interface Module has a keypad panel and easy to read graphics LCD display Simple to set up and use with a step by step Quick Start program Operating status and diagnostic information as well as help text aids in set up and operation The drive may be operated from the OIM or from a remotely mounted control station 230 VAC 50 60 Hz Non Regenerative 1 1 2 Hp 30 Hp 230 VAC drives use equivalent rated 460 VAC drives listed below with required 916FK0100 460 VAC 230 VAC conversion kits 240 VDC Armature 150 VDC Field Full Load Rated P Full Load RMS Rated Field Catalog Mult List Hp Rating AC Line Current ria Current Number Sym Price 1 1 2 10 7 10 3FN4042 VS50D 3 870 5 19 20 10 10FN4042 VS50D 3 885 230 VAC 50 60 Hz Regenerative 1 1 2 Hp 30 Hp 230 VAC drives use equivalent rated 46
66. ference the MD60 User Manual D2 3499 for details on the filters and their installation Also be sure to follow recommended wiring practices for drives and motors as identified in the MD60 User Manual MD60 EMC Filters Description Model Number List External EMC Filter for Short Cable Distances D60 EMC filter 5 meter 1 2 2 HP 230 V 3 ph 6MDF 9P5AS 57 External EMC Filter for Long Cable Distances MD60 EMC filter 100 meter 1 4 2 HP 230 V 3 ph 6MDF 9P5AL 90 MD60 EMC filter 100 meter 3 5 HP 230 V 3 ph 6MDF 021BL 113 MD60 EMC filter 100 meter 1 2 2 HP 460 V 3 ph 6MDF 5P7AL 85 NOTE The 230 Y single phase input drives are available with a factory installed filter option and may not need to have the external filters listed above installed to meet the required emission standards Contact Reliance or reference the User Manual D2 3499 for details MD60 MD65 NEMA 1 Bezel Kit The NEMA 1 Bezel Kit provides a convenient means for panel or door mounting of MD1CC CopyCat Keypad The kit includes a one meter RJ45 to RJ45 cable Model Number MDBZL N1 68 MD 60 AC Drives DB Resistor Kits The MD60 drives include power terminals for connecting low power dynamic braking resistors These resistors are not enclosed and must be separately mounted For enclosed braking resistor options reference the GV3000SE section page D 66 Select resistors from the chart on this p
67. formation based on application horsepower and duty cycle Resistors must be purchased from the selection on page D 65 or from a local resistor supply house Snubber Resistor Resistor Approx HP Duty Transistor Model Min Max Resistor Number Ohms Ohms KW 75 100 100 M3452H150B7 5 7 15 20 M3452H150B7 5 17 30 125 200 60 M3452H150B7 5 6 90 100 M3452H200K6 3 8 4 150 40 M3452H150B7 5 7 75 250 60 M3452H150B7 5 6 112 80 M3452H200K6 3 8 4 150 100 M3452H300K6 2 5 3 187 40 M3452H150B7 5 6 5 90 300 50 M3452H150B7 5 5 5 112 60 M3452H200K6 3 8 135 100 M3452H300K6 2 5 3 224 40 M3452H150B7 5 5 5 104 350 60 M3452H300K6 2 5 4 157 80 M3452H300K6 2 5 3 208 400 20 M3452H150B7 5 9 60 75 M3452H300K6 2 5 3 225 DISCOUNT VS 1AC 45 BALDOR RELIANCEF GV3000 AC Drives BRAKING LOOSE SNUBBER TRANSISTOR KITS 8 RESISTOR INFORMATION Snubber Transistor Braking Kits Transistor Only Open Frame Type For deceleration of high inertia loads as well as for correction of speed command overshoot Snubber Transistor Braking Kits provide the circuitry needed to connect the drive s DC bus to a matched resistor package for regulation of regenerative energy Model Number 2ST40027 Snubber Transistor Kit These snubber transistor circuits are designed to be mounted into another enclosure in engineered applications Matching the appropriate resistor package then allows the user to optimize the braking capacity
68. gramming style as the popular general purpose Reliance Electric MD65 V S Drive This logically organized easy to use method makes the GV6000 family member the easiest drive in it s class to set up and operate Text can be displayed in multiple languages and with a single keystroke of the display key you can toggle among four different metering screens Tactile feedback on keys Similar version is available for remote cabinet door mounting in NEMA 4X 12 1P66 rating Full Numeric version of OIM available for mounting locally on the drive or remotely in a NEMA 1 Bezel Kit All versions support CopyCat programming Each OIM includes opeartor control keys for Start Stop Reset Increase Decrease Speed Forward Reverse Jog and Auto Manual Specifications 1 0 e 6 programmable digital inputs available in 24VDC or 115VAC Digital input 6 can be selected as a hardware enable not interpreted by software 2 analog inputs 10V 4 20mA 11 bit sign 24VDC supply for digital inputs not present on 115VAC input models 10V reference voltage outputs for potentiometer supplies 3 programmable digital outputs dry contacts 1 form C 1 form A and 1 form B 2 analog outputs 10V 4 20mA 11 bit sign Encoder input 3 channel differential inputs also usable as a frequency reference 12V DC 5 V DC encoder power supply Braking Transistor Built in e Standard on frames 0 4 optional on frames 5 6 e Optional braking resistor can be d
69. horted or Features Environmental Conditions Keypad Display grounded motor overload encoder loss External Output LED trip condition indicators codes fault relay output Short Circuit Phase to phase phase to ground Electronic Motor Overload Meets UL508C 12T Temperature 0 to 40 C NEMA 1 0 to 50 C Power Module IP00 Cooling Forced air Enclosure NEMA 1 NEMA 4X NEMA 12 IP20 and IP00 Altitude Sea level to 3300 Feet 1000 Meters Humidity NEMA1 5 to 95 RH Non Condensing NEMA 4X To 100 RH Condensing Storage Temperature 40 to 65 C Display 4 digit bright 7 segment LED readout 14 discrete LED indicators Keys 9 key membrane with tactile feedback Functions Output status monitoring Digital speed control Parameter setting and display Diagnostic and Fault log display Motor run and jog Control Auto Manual toggle LED Indicators Forward run command Reverse run command Jog active Auto Manual Indication Monitor display indication Remote Mount Optional remote mountable LCD keypad full text display multi language support quick start menu NEMA 12 rating 5 meter distance capable with included cable Trip Control Method Last 10 trips retained in memory with elapsed time stamp Microprocessor controlled PWM output selectable encoderless vector sensorless vector or V Hz inverter Specifications Motor Feedback PWM Frequency Sele
70. ial Input Marker Pulse A 12 VDC 5 VDC Common 250mA Power Supply for encoder 8 12 VDC 5 VDC Output Power Terminals Terminal Function BR1 DC Brake DB Resistor Connection BR2 DC Brake DB Resistor Connection DC DC Bus DC Bus Connection DC DC Bus DC Bus Connection PE PE Ground Protective Earth Motor Ground Motor Ground R 11 R L1 AC Line Power S L2 S L2 Three Phase R S amp T T L3 T L3 Single Phase R amp S Only U T1 U T1 To Motor V T2 V T2 To Motor W T3 W T3 To Motor PS AUX Frames 5 amp 6 Only Auxiliary Control Voltage PS AUX Frames 5 amp 6 Onl Auxiliary Control Voltage 29 BALDOR RELIANCEP GV6000 AC Drives Output Ratings 240 VAC Output Amps 110 OL Duty Nominal Power Ratings Application Data 110 OL Duty 150 OL Duty Model Number 240 VAC Variable Torque Constant Torque Watts Loss Applications Applications 0240 VAC 240 VAC Q 4 khz 1 Min 240 VAC 2P2xx 0 2 2 2 4 3 3 0 37 0 5 0 25 0 33 0 7 1 7 46 4P2xx 0 42 4 8 6 4 0 75 1 0 55 0 75 1 4 3 3 61 6P8xx 1 6 8 9 12 1 5 2 1 1 15 2 4 5 9 77 9P6xx 1 9 6 10 6 14 4 2 2 3 1 5 2 3 4 8 3 98 015xx 1 15 3 16 8 23 4 5 2 2 3 5 7 13 7 179 022xx 1 22 24 2 33 5 5 7 5 4 5 8 3 19 9 208 028xx 2 28 33 44 75 10 5 5 75 10 7 25 7 269 6v21 042xx 3 42 46 2 63 11 15 7 5 10 16 38 5 368 052xx 3 52 63 80 15 20 11 15 19 8 47 7 436 070xx 4 70 78
71. ions include Start Stop Jog Preset Speeds Accel Decel Rate 1 or 2 selection Forward Reverse etc e Braking resistors mount to the rear on the extended heatsink e Door Mounted Graphical LCD OIM for drive configuration and operation e Added Safety of a fused input with rotary through the door disconnect handle includes lock out tag out capability 240 50 60 Hz Input Ratings 0 5 to 10 HP Modified Maximum Drive Currents Amps Standard Horsepower Model Rating 110 OL Number 1 Continuous1 Min 150 OL List 2P2CTNN A 4P2CTNN A 1 0 75 4 2 4 8 6 4 3 530 6P8CTNN B 1 5 6 8 9 12 3 705 PE 015CTAN C 5 3 15 3 17 4 23 2 4 130 022CTAN D 7 5 5 22 24 2 33 4 940 028CTAN D 460 50 60 Hz Input Ratings 0 5 to 20 HP Modified Maximum Drive Currents Amps Standard Horsepower Model Rating 110 OL Number 1 1P1CTNN 2P1CTNN 3P4CTNN 005CTNN 008CTNN 011CTAN 022CTAN 027CTAN Continuous1 Min 0 33 11 1 2 1 6 3 565 150 OL 2 List 6SP4DS OO OO gt gt gt 1 These units cannot be modified with any additional modifications without consulting factory 2 Overload of 150 or more for 1 minute Dependent upon actual motor full load amp rating versus the drive continuous amp rating Dimensions i Enclosure Size Approximate Weight Frame Size MEET x W x D mm inches Kg Ibs A amp B 400 15 75 X 300 11 81 X 254 10 11 8 26 C amp D 600 23 62 X 3
72. ithout OIM Model Numbers 6SP41F xxxBxAx are with internal EMC filter DISCOUNT VS 1AC 21 BALDOR RELIANCET SP600 Options The SP600 Product Family is easily modified with a full line of optional kits and accessories including communications resistors filters OIMs and cables Braking Resistor Kits Low Energy SP600 drives in frames A B C D B4 D4 and 2 include mounting provisions for low energy braking resistors Dependant upon the drive power rating these resistors will provide momentary braking capacities of about 6 10 enough to handle most simple deceleration needs as well as speed overshoot correction Consider other braking options from the GV3000 SE section of this catalog should more braking capacity be required Minimum braking resistances apply see page D 41 Wattage depends on application 200 240 VAC Braking Resistors Model Number Frame Brake Resistance List 6SP2 DB1 A A 62 156 6SP2 DB1 C C 62 156 380 480 VAC Braking Resistors Model Number Frame Brake Resistance List 6SP4 DB1 C C 115 156 6SP4 DB1 D D D4 62 156 6SB4 DBI 2 2 156 Communication Modules Network Options Network connectivity can be achieved by adding one of the options listed below Model Number Description List RECOMM CNET ControlNet 468 RECOMM PBUS Profibus 494 RECOMM IBUS Interbus S 676 RECOMM 485 RS485 DF1 307 RECOMM H485 P1 N2 or Modbus RTU 540 UL C Cnzzs SP600 AC Driv
73. king transistor allows connection to remote braking resistor for enhanced performance needs 200 240 V 50 60 Hz 1 Phase Input 230 V 3 Phase Output With Integral EMC Filter MOCOS ROI CITO IE a Number Framesize m OutputCurrent Watt Loss List 6MDAN 1P5111 A 0 25 1 5A 25 345 6MDAN 2P3111 A 0 5 2 34 30 373 6MDAN 8P0111 B 2 8 0A 80 593 6MDAN 012111 C 3 12 0A 110 707 200 240 V 50 60 Hz 1 Phase Input 230 V 3 Phase Output Tr Ln EE A aati ats Number Framesize MP Output Current Watt Loss List 6MDAN 1P5101 A 0 25 1 5A 25 311 6MDAN 2P3101 A 0 5 2 34 30 339 6MDAN 012101 C 3 12 0A 110 667 200 240 50 60 3 Phase 3 Phase Model Number Frame Size HP OutputCurrent WattLoss List 6MDBN 1P5101 A 0 25 1 5A 25 311 DISCOUNT VS 1AC BALDOR RELIANCEF MD60 ACCESSORIES NEMA 1 1P30 Kit The MD60 AC drive has an enclosure rating of IP20 but includes provisions to mount a NEMA 1 1P30 kit This kit provides a metal conduit plate for attaching user conduit as well as a plastic top cover for the drive MD60 NEMA 1 1P30 Kits Description Model Number List MD60 IP30 NEMA 1 Kit Frame B 6MD NM1B 15 EMC Compliance Filters The MD60 drive has been designed to conform to global industry standards for EMC compliance including Europe and Australia To meet the conducted and radiated emission standards of EN 61800 3 the filters listed below must be used depending on the motor cable length Re
74. lacement power factor 0 98 across entire speed range e Sine coded PWM with adjustable carrier frequency volts per hertz sensorless vector and vector control e Speed regulation 0 001 across a 120 1 speed range 1000 1 operating range 250 rad sec bandwidth Flux Vector Control e Frequency stability long term 0 01 of base speed with digital input 0 4 of base speed with analog speed reference GV6000 AC Drives Ratings e 110 OL 110 of rated horsepower for 1 minute 150 of rated horsepower for 3 seconds e 150 OL 150 of rated horsepower for 1 minute 200 of rated horsepower for 3 seconds NOTE Single phase operation requires 50 de rating of drive output current See horsepower rating chart GV6000 Brake Resistor Specifications The GV6000 has various combinations of internal braking transistors and either internal or external braking resistors The minimum resistance that may be used that prohibits damaging this internal transistor as well as the recommended resistance by motor voltage and horsepower is specified in publication D2 3489 The average power dissipation of the braking mode must be estimated and the power rating of the Dynamic Brake Resistor chosen to be greater than the average regenerative power dissipation of the drive 27 BALDOR RELIANCEP GV6000 AC Drives GV6000 Specifications The specifications below are applicable over a constant torque range e i Sensorless Vector Vector Vecto
75. lt Function Analog Input 1 Default 4 20 mA 1 Analog Volts In1 See Param 320 2 Analog Volts In1 Term 17 amp 18 Analog Input 2 Default volts 3 Analog Volts In2 See Param 320 4 Analog Volts In2 Term 19 amp 20 5 Reference Common Analog Output 1 Default volts 6 Analog Volts Out Drive Output Frequency 7 Analog Volts Out1 See Param 342 8 Analog Current Out1 9 Analog Current Out 10 Reserved 11 Digital Out1 NO Fault 12 Digital Out1 C 13 Digital Out1 NC 14 Digital Out2 NO Running 15 Digital Out2 C 16 Digital Out2 NC 17 Analog Current In1 See Param 320 18 Analog Current In1 19 Analog Current In2 20 Analog Current In2 21 10 VDC Ref Out 22 10 VDC Ref Out 23 Reserved 24 24 VDC Int Internal 24 V logic supply 25 Digital In Ext Com Logic Common 26 24V Int Com Power Supply Common 27 Digital In 1 Stop Clear Fault 28 Digital In 2 Start 29 Digital In 3 Function Loss 30 Digital In 4 Jog 31 Digital In 5 Auto Manual 32 Digital In 6 Speed Select 1 Typical Power Terminals Terminal BR1 BR2 DC DC TU Oo DIE lt CIF DC Brake DC Brake DC Bus DC Bus Motor Ground PE Ground U T1 V T2 W T3 R L1 S L2 T L3 1 Terminal chart defines the 24 V interface 1 0 configuration Note 115 VAC 1 0 card defined separately DB resistor connection DB resistor connection Frame 2 only Frame 2 only Motor output
76. ng with a settable delay time between attempts since many variable torque applications operate unmanned in remote areas Also with 2 Analog Inputs standard an isolated 0 10 VDC and a 4 20 mA input the MD60 can be easily used in any automated process control system MD 60 AC Drives CE Gnzzs MDEC ACDRVE PELIANCE ELECTRIC CONSTANT TORQUE USE For simple conveyors mixers agitators and machine applications the MD60 provides a cost effective solution These applications will benefit from the 200 Over Current for 3 seconds capacity of the MD60 Microdrive Some additional advanced parameter features include e V Hz Operation Speed Regulation 2 of motor base speed 40 1 Operating Speed Range e Start Boost Voltage Boost improves breakaway torque at the low end of the drive s frequency output e S Curve Acceleration may enhance performance and control of high inertia loads by tapering changes in speed rates during initial starts as well as when approaching desired speed settings e Dynamic Braking provides the ability to dissipate excessive DC Bus Voltage and thereby avoid High Bus Fault conditions normally experienced during extremely fast acceleration rates as well as in fast deceleration rates where the inertia of the load attempts to overhaul the electric motor GLOBAL DESIGN MD60 is a true Global Design which meets the standards for North and South America Europe Australia and Asia One pr
77. nnsnnnnnnnnnnnnnnnnnannnnnnnnnnnnnnnnnnnnnnnnn DISCOUNT VS 1AC 10 MD AC Driv BALDOR RELIANCEF 65 AC es Communication Cards DeviceNet EtherNet and Profibus Cards The Network communication cards mount internal to the MD65 drive and receives power from the drive and network Switches or parameters allow node and data rate configuration Explicit UCMM Polled Cyclic and Change of State messages are supported Specify cover kit according to the drive frame size MD65 Communication Cards amp Cover Kits Description Model Number List MD65 DeviceNet Communication Card MDCOMM DNET 317 MD65 Profibus Communication Card MDCOMM PBUS 424 B Frame Communication Cover Kit 1 6MD COMMCVRB 23 C Frame Communication Cover Kit 1 6MD COMMCVRC 23 1 The 6MD COMMCVRB and 6MD COMMCVRC Communication Cover Kits are required for installation of the Communication Cards in the MD65 drive Communication Card Mounting Dimensions Drive Dimensions NEMA 1 1P30 Kit with Communication Option Dimensions shown in mm in Multi Drop Network Capabillity Connect up to five 5 MD65 or MD60 drives with one Network DeviceNet or EtherNet Card Provides the lowest cost Industry Solution for DeviceNet or EtherNet Networks Requires one MD65 and DeviceNet or EtherNet Card set for Multi Drop Configuration MD60 or MD65 Drives are linked to Multi Drop MD65 Drive using standard RS485 Serial Modbus Commuication Port built into the drive Typical N
78. not more than 3dba when compared to sine wave operation e Unique transistor control circuits also allow drive to operate at motor distances of up to 600 feet with proper cable type before output filtering considerations must be applied e Tested to ensure that the waveform at the motor conduit box will not exceed the limits specified in NEMA MG1 31 40 4 2 at lead lengths of 200 ft SERVICE CONDITIONS e Elevation to 3300 ft 1000 meters De rate 3 for every 1000 ft above 3300 ft e Operating temperature ranges NEMA 1 Enclosures 0 C to 40 C IP20 Enclosures 0 C to 50 C NEMA 4X 12 Enclosures 0 C to 40 C e Atmosphere Non condensing relative humidity 5 to 95 e AC line voltage variation rated input voltage 10 e AC line frequency variation 50 60 Hz 48 62 Hz e Storage temperature 40 C to 65 C 40 F to 149 F RATINGS e 110 OL 110 of rated horsepower for 1 minute 150 of rated horsepower for 3 seconds e 150 OL 150 of rated horsepower for 1 minute 200 of rated horsepower for 3 seconds NOTE Single phase operation requires 50 de rating of drive output current See horsepower rating chart APPLICATION DATA e Pulse width modulation PWM sensorless vector control or volts per hertz control e Displacement power factor 0 96 e Frequency stability long term 0 01 of base speed with digital keypad 0 5 of base speed with analog speed reference e Linearity speed
79. nt 5A maximum resistive 2 amps maximum inductive Output Conditions 7 Programmable Conditions 37 BALDOR RELIANCEF GV3000 AC Drives GV3000 Closed Loop Vector NEMA 1 Enclosure Catalog Heavy Duty Normal Duty List Mult VS Alternate 2 Number Hp kW Cont Amps Peak Amps Hp kW Cont Amps Peak Amps Price Sym 230 Volts Three Phase Input 2V2160 2 1 5 8 5 12 8 2 1 5 8 5 9 4 1 615 VS1AC VS1GV22 1B 15V2160 15 11 53 3 80 15 11 53 3 58 6 3 721 VS1AC VS1GV215 1B 460 Volts Three Phase Input 3V4160 3 2 2 5 3 8 3 2 2 5 3 5 8 1 718 VS1AC VS1GV43 1B 10V4160 10 7 5 14 2 21 3 10 75 14 2 15 6 3 097 VS1AC VS1GV410 1B 20V4160 20 15 27 40 5 20 15 27 29 7 4 677 VS1AC VS1GV420 1B 25G4160 20 15 27 40 5 25 18 7 30 4 33 4 5 078 VS1AC VS1GV425 1B 50R4160 40 30 56 84 60 45 12 79 2 15 513 VS1AC VS1GV450 1B 75R4160 60 45 71 106 5 75 56 93 102 3 15 513 VS1AC VS1GV460 1B 7574160 60 45 71 106 5 75 56 93 102 3 19 004 VS1AC VS1GV4100 1B 125R4160 100 75 122 183 125 93 168 184 8 29 021 VS1AC VS1GV4150 1T 200V4160 200 150 240 360 200 150 240 264 30 186 VS1AC VS1GV4200 1T 250V4160 250 187 302 453 250 187 302 332 2 33 372 VS1AC VS1GV4250 1T 300V4160 300 224 361 541 5 300 224 361 397 1 39 602 VS1AC VS1GV4300 1T 350V4160 350 261 414 621 350 261 414 455 4 41 646 VS1AC VS1GV4350 1T 400V4160 400 298 477 525 400 298 477 525 45 418 VS1AC VS1GV4400 1T 460 Volts Three Phase Input with Disconnect Swi
80. oduct for the World Market BALDOR RELIANCEF Drive Ratings Drive Ratings MD60 AC Drives Output Model Number Frame Input Voltage kW Le bl Size 230V 50 60 Hz 02 0 25 15A 6MDAN 1P5111 A 1 Phase 037 05 2 3A 6MDAN 2P3111 A With Integral EMC Filter 15 2 8 0A 6MDAN 8P0111 B 230V 50 60 Hz 2 2 3 12 0A 6MDAN 012111 C 1 Phase 0 2 0 25 1 5A 6MDAN 1P5101 A No Fitter 0 37 05 2 34 6MDAN 2P3101 A 230V 50 60 Hz 2 2 3 12 04 6MDAN 012101 C 3 Phase 0 2 0 25 15A 6MDBN 1P5101 A Drive Parameters Basic Group No Parameter Name Default Value P031 Motor NP Volts Varies P032 Motor NP Hertz 60 Hz P033 Motor OL Current Varies P034 Minimum Frequency 0 Hz P035 Maximum Frequency 60 Hz P036 Start Source 0 Keypad P037 Stop Mode 1 Coast Clear Fault P038 Speed Reference 0 Drive Potentiometer P039 Accel Time 1 5 0 sec P040 Decel Time 1 5 0 sec P041 Reset to Defaults 0 ldle State P043 Motor OL Ret 0 Disabled 1 The 12 parameters in this group represent the minimum requirement for basic operation Drive Parameters Advanced Group No Default Value A051 Digital Int Select 4 Preset Frequencies A052 Digital In2 Select 4 Preset Frequencies A055 Relay Output Select 0 Ready Not Faulted A056 Relay Output Level 0 A067 Accel Time 2 10 0 sec A068 Decel Time 2 10 0 sec A069 Internal Frequency 0 0 Hz A070 Preset Frequency 0 0 0 Hz A071
81. of 150 for one minute Flexible mounting options NEMA 1 or NEMA 4X 12 Integral keypad operator interface and local speed control Basic set of less than 30 programming parameters Power ratings from 1 Hp to 5 Hp 230Vac 20 Hp 460 Vac and 10 Hp 575 Vac Operator Interface Module Integral Drive Mounted Display Lines 4 Character LED display Programmable Preset Speeds Three Analog Output One 0 10 VDC Auto Restart Yes Up to 10 attempts Frequency Avoidance One Band Fault History Last Three Faults Digital Inputs Dedicated control terminals for start stop forward reverse and fault reset Analog Input One 0 10VDC or 4 20 mA Digital Output One Form C Relay Maximum Load 20 Hp 460 VAC Overload Capacity Drive Output 150 for One Minute Input Voltage Ranges 115VAC 208 230VAC 380 460VAC and 575VAC Input Voltage Tolerance 10 10 Rated Input Frequency 50 60 Hz 5 Carrier Frequency 4 6 or 8 KHZ Operating Temperature 10 to 40 C Volts Hz Linear or Custom V Hz Frequency Control Range 0 to 240 Hz Accel Decel Range 0 5 to 90 Seconds Keypad Speed Control Yes Function Loss Function loss input open High Bus Voltage DC bus voltage above trip level Low Bus Voltage DC bus voltage below trip level Over Current short circuit or ground fault Drive output exceeds 200 rating Thermostat Drive Overload Excess drive temperature
82. of the snub ber based on peak and continuous loads Be sure to follow the minimum resistance values provided in the table Using resistances lower than the published data will result in excess current being allowed through the circuit and damaging the snubber transistor Snubber Model Number AC Line Voltage 2ST20019 120 sec 2ST40009 9 79 Cont No 1 640 460 28740125 125 6 120 sec No 3 185 2ST40300 Cont 1 See page D 64 for Cabinet Dimensions INSTRUCTION MANUAL D2 3291 Snubber Resistor Selection Information For use witgh the Snubber Transistor Kits Snubber Transistor Kits require a resistor for dissipation of regenerative energy as heat By selecting the proper reisgtor the use can opgtimize the brakingb performance of the drive system The following table provides resistor sizing information based on application horsepower and duty cycle Resisgtors ust be purchased from a local resistor supply house E Snubber Resistor Resisgtor Approx HP Transistor Min Max Resistor Mode Number Ohms Ohms KW 1 5 60 2ST20019 30 58 3 100 2ST20019 20 35 3 75 7 1 2 10 60 2ST20019 20 29 3 75 75 100 100 2ST40125 6 7 75 125 200 20 2ST40125 6 7 75 250 40 2ST40125 6 7 75 100 2ST40300 2 5 3 187 200 40 2ST40125 6 6 5 90 100 2ST40300 2 5 3 224 350 20 2ST40125 10 11 52 80 2ST40300 2 5 3 208 400 60 2ST40300 2 5 3 179 46 BALDOR RELIANCEN DC2 DC DRIVES DC2 DC Drives f
83. or 1 4 2 Hp 115 230 VAC 1 Phase 50 60 Hz 1 4 thru 2 Hp PMDC Applications General purpose industrial use with Permanent Magnet or Shunt W DC Motors and Shunt Wound Do Motors Features General purpose industrial use Available in open chassis plate style NEMA 12 or NEMA 4 4X Operates from either local or remote operator controls for added mounting flexibility Note reversing drives are local control only All models have a single surface mount design printed circuit board Jumper reconnection for Line voltage Horsepower Feedback S curve and Zero speed Adjustments for Min and Max speed Current Limit IR drop Compensation and Accel Decel rate 20 1 constant torque speed range 30 1 constant torque speed range with tachometer feedback FORWARD REVERSE on ancem E biernicks W lon Cu AS 1 4 1Hp 115 VAC 90 VDC Armature 50 VDC Field 2 1 2 2Hp 230 VAC 180 VDC Armature 100 VDC Field 2 Regulator Type Catalog Number List Price Mult Sym BC Series Alternate b e Open Chassis DC2 Series 40 Torque Regulator DC2 43U 400 VS3DC NOTE Conduit hole plugs are standard on NEMA 12K designs Conduit hubs are standard on NEMA 4 12 designs only Conduit hubs for either design can be ordered through Renewal Parts by referencing Reliance Part Number 608826 2A a Jumper selection for 115VAC 90 VDC or 230 VAC 180 VDC b Instrument Interface units also provide auxiliary control relay contact rate
84. power must be routed into the top of the filter Outgoing AC power is then routed from the bottom of the filter to the bottom of the SP500 Mounting hardware and flying leads from the Mains Filter are provided Mains Filter 2DF2282 is rated for 1 phase or 3 phase 50 60 Hz 250 VAC max Mains filters 2DF4283 2DF4284 and 2DF4285 are rated for 3 phase 50 60 Hz 500 VAC max Hp SP500 Mains Filter List Price Mult Model Number Model Number Sym 3 1SU21003 2DF4283 735 VS1AC 5 1SU21005 2DF4283 735 VS1AC 7 1 2 1SU41007 2DF4284 827 VS1AC 10 1SU41010 2DF4284 827 VS1AC 15 1 15U41015 2DF4285 2 160 VS1AC 20 1 1SU41020 2DF4285 2 160 VS1AC 1 For 15 Hp and 20 Hp SP500 a cover kit and a filter kit are both required to conform to CE requirements Low Energy Snubber Braking Kit Low Energy Snubber Braking Kit provides rapid deceleration of the drive motor by providing 150 intermittent braking of the motor The kit dissipates the power regenerated by the motor during deceleration through resistors The braking resistors are sized to provide a maximum of three stops per minute taking 4 seconds for a complete stop when the motor is connected to a load that has six times the NEMA motor inertia The kits are provided in a separate enclosure for field wiring SP500 SP500 Kit Model Resistor Style List Price Mult Voltage Hp Rating Number Wattage y Symb 460 15 20 2DB4020 1600 C 1 808 VS1AC 35 BALDOR RELIANCEP SP500 AC Drives
85. provide the circuitry needed to connect to the DC bus and to a matched resistor package for regulation of regenerative energy These snubber transistor circuits are packaged in wall mountable protected enclosures with IP20 type connections Note Maximum on rating is 60 seconds Snubber me 7 Cabinet Enclosed Dimensions Inches AC Line Amps DC Minimum Cabinet z Voltage Model Load Ohms List Style Style Width Height Depth Number M3 Wall 3 00 12 75 8 70 230 M3575TL30 30 12 5 M3 1 571 M7 Wall 7 00 12 75 8 70 M3575TL60 60 6 25 M4 1 854 M10 Wall 10 00 12 75 8 70 M3575TH75 75 10 M4 1 854 B4 Wall 4 00 17 75 8 00 M3575TH125 125 6 B4 2 879 B5 Wall 5 65 17 75 8 00 ago M3575TH150 150 5 B4 3 682 B7 Wall 700 1775 8 00 M3575TH200 200 3 75 B7 4 120 B10 Wall 10 00 17 75 8 00 M3575TH300 300 2 5 B7 4 429 B10D Wall 10 00 17 75 11 70 M3575TH600 600 1 25 B7 6 086 61 Floor 25 00 38 00 22 00 G2 Floor 25 00 47 00 22 00 G3 Floor 25 00 56 00 22 00 Model Number M3575TH15 Snubber Transistor Kit and Model Number M3575H5B Snubber Resistor Kit INSTRUCTION MANUAL D2 3439 DISCOUNT VS 1AC 1 List price is for resistor module only 42 BALDOR RELIANCET Snubber Resistor Kits Resistor Only Protected Enclosure IP20 Type Snubber Transistor Kits require a resistor for dissipation of regenerative energy as heat By selecting the proper resistor the user can optimize the braking performance Note Maximum On rating is 60
86. puts WALL MOUNT Drives SP MODELS e Motor Power Rating 0 5 to 50 HP 0 33 to 37 kW Input Voltage 380 415 460 480 VAC 50 60 Hz e Enclosure NEMA 1 Ventilated IP20 Mounting Wall Machine Panel Mount as IP20 Models available with LCD OIM keypad e Models available with internal EMC filter e Zero clearance side by side mounting ERSP 380 480 VAC 50 60 Hz In ut Ratings 0 5 to 50 HP Horsepower Rating Drive Amps 480 V urnes wn er HO TS contin List Applications Applications 1P1CTNN A e 0 5 0 33 1 1 1 2 1 6 1 108 3P4BTNN A 2 15 3 4 4 5 6 1 035 005BTNN B 3 2 5 5 5 15 1 139 6SP401 011CTAN C 7 5 5 11 12 1 16 5 1 896 027BTAN D 20 15 27 33 44 2 917 052CTAN E 40 30 52 60 80 5 720 065CTAN E 50 40 65 78 104 7 176 1 Overload of 150 of rated current for 1 minute dependant on actual motor full load amps versus drive continuous amp rating 2 Rated for 240 VAC input and 4 kHz switching frequency 3 See amp rating chart for currents 208 VAC Model Numbers 6SP201 xxxBxxx are without OIM Model Numbers 6SP201 xxxCxxx are with OIM Model Numbers 6SP201 xxxCxAx are with OIM and internal EMC filter DISCOUNT VS 1AC 18 BALDOR RELIANCEN SP600 AC Drives WALL MOUNT Drives SB MODELS pS CE Gnzzs e Motor Power Rating 20 to 200 HP 15 to 132 kW e Input Voltage 380 415 480 VAC 50 60 Hz UL e Enclosure NEMA 1 Ventilated IP20 e Mounting
87. puts Flying start to quickly synchronize drive output to a rotating load Slip compensation and droop control Quick start feature to easily configure and tune the drive using text based prompting eliminating the need for parameter familiarity Pull apart control and encoder terminal blocks and removable conduit plate to allow easy wiring and maintenance Patented reflected wave reduction algorithm and integral common mode cores for noise reduction QUIET MOTOR OPERATION UP TO 600 FT The GV6000 controller uses IGBT transistors switched at frequencies up to 10 kHz to reduce PWM induced motor audible noise This technology limits the increase of audible motor to not more than 3dba when compared to sine wave operation Unique transistor control circuits also allow drive to operate at motor distances of up to 600 feet with proper cable type before output filtering considerations must be applied Tested to ensure that the waveform at the motor conduit box will not exceed the limits specified in NEMA MG1 31 40 4 2 at lead lengths of 200 ft Specifications General e 0 to 40 C 1000m altitude without derating in NEMA 1 Configuration 0 to 50 C for IP20 Configuration e 5 to 95 humidity non condensing e Input voltage operating range exceeds 10 of nominal and 47 to 63Hz frequency e Operational on single phase power for 50 of the nominal current rating e 97 5 efficiency nominal line voltage and rated amps e Disp
88. r Specification Volts per Hertz Sensorless Vector w feedback w o feedback w feedback Speed regulation accuracy 0 5 0 5 0 1 0 1 001 Specified speed range 40 1 80 1 80 1 120 1 120 1 Operating speed range 40 1 80 1 80 1 120 1 1000 1 Velocity bandwidth with slip compensation 10 rad s 20 rad s 20 rad s 50 rad sec 250 rad sec Minimum settability of velocity bandwidth slip compensation 0 1 rad s 0 1 rad s 0 1 rad s 0 1 rad sec 0 1 rad sec Torque Regulation w o feedback 5 600 rad sec bandwidth w feedback 2 2500 rad sec bandwidth Dimensions Frame Overall Depth 0 13 23 336 0 4 33 110 0 7 87 200 0 1 13 23 336 0 5 31 135 0 7 87 200 0 2 13 48 342 5 8 74 222 0 7 87 200 0 3 20 37 517 5 8 74 222 0 7 87 200 0 4 29 87 758 8 8 66 220 0 7 94 201 7 5 25 37 644 5 12 16 308 9 10 84 275 4 6 38 43 976 3 15 9 403 9 10 85 275 5 inches mm 41 027 TA GV6000 ae Digital Input Voltage A 24 VDC B 115 VAC Input Voltage 2 230 VAC 4 460 VAC 5 575 VAC Braking Transistor G 325 VDC w o Pre Charge N none J 650 VDC w o Pre Charge T Included K 810 VDC w o Pre Charge N 325 VDC w Pre Charge R 650 VDC w Pre Charge T 810 VDC w Pre Charge Continuous Amps Enclosure 1 NEMA 1 Air Cooled Instruction Manuals D2 3540 GV6000 User Manual D2 3548 GV6000 Remote NEMA 4X 12 IP66 OIM Installation Manual D2 3516 Remote NEMA 1 OIM Bezel Kit Installation Manual D2 3488 v s
89. reference to output frequency 1 0 SP600 AC Drives SP600 BRAKE RESISTOR SPECIFICATIONS The SP600 has various combinations of internal braking transistors and either internal or external braking resistors The minimum resistance that may be used that prohibits damaging this internal transistor as well as the recommended resistance by motor voltage and horsepower is specified on page D 41 The average power dissipation of the braking mode must be estimated and the power rating of the Dynamic Brake Resistor chosen to be greater than the average regenerative power dissipation of the drive 14 BALDOR RELIANCEE SP600 AC Drives SP600 SPECIFICATIONS The specifications below are applicable over a constant torque range Specification SVC Speed regulation accuracy with slip compensation 0 5 40 1 speed range 0 5 80 1 speed range Operating speed range with slip compensation 40 1 80 1 Dynamic speed accuracy speed response to a 95 step load change 0 5 base speed 0 5 base speed Velocity bandwidth with slip compensation 10 rad s 20 rad s Minimum settability of velocity bandwidth slip compensation 0 1 rad s 0 1 rad s DIMENSIONS Frame Overall Height Mount C C Height Overall Width Mount C C Width Depth Weight A 8 89 225 8 8 33 211 6 4 82 122 4 3 71 94 2 7 08 179 8 5 97 2 71 B 9 24 234 6 8 67 220 2 6 76 171 7 4 83 122 7 7 08 179 8 7 93 3 60 B4
90. rence supply 11 Digital Out1 NO Fault 12 Digital Out1 C 13 Digital Out1 NC Analog Input 1 Default 4 20 mA 14 Analog Volts In1 See Param 320 15 Analog Volts Int Non isolated 16 Analog Current Int 17 Analog Current In1 Analog Input 2 Default 0 to 10 VDC 18 Analog Volts In2 See Param 320 19 Analog Volts In2 Isolated 20 Analog Current In2 21 Analog Current In2 Analog Out amp 22 Reference Common 23 Analog Volts Out Drive Output Frequency 24 Digital Out2 NO Running 25 Digital Out2 C 26 Digital Out2 NC Power Terminals Terminal Function R R L1 AC line inpu S S L2 AC line inpu T T L3 AC line inpu DC BR1 DC Brake DB resistor connection BRK BR2 DC Brake DB resistor connection U um Motor outpu V V T2 Motor outpu W W T3 Motor outpu PE PE Ground Protective Earth PE PE Ground Protective Earth Output Ratings Model Number 200 240 VAC Three SP600 AC Drives Output Amps Nominal Power Ratings 110 OL 150 OL 240 VAC Input 208 VAC Input Duty Duty 2P2 22 24 33 25 27 37 037 05 0 25 0 33 4P2 42 48 64 48 55 74 0 75 1 0 55 0 75 6P8 68 9 12 78 103 138 15 2 11 15 9P6 96 106 144 11 121 165 22 3 15 2 6SP2Xx 015 153 174 232 1 5 192 262 4 5 3 3 022 22 242 33 253 278 379 55 75 4 5 028 28 33 44 322 379 506 75 10 55 75 042 42 462 63 43 555 74 11 15 75 10 054 54 63 84 621 724 96 6 15 20 11 15 070
91. rial converter comes standard with a one meter cable The cable length can be extended by e Replacing the RECBL M10 with a longer cable see table e Extending the cable with extension option DPI cables drive side of converter box cannot exceed 10 meters DPI Drive Peripheral Interface Software Serial Converter Model No RECOMM VSU232 437 Software ONLY Model Number RECOMM VSUTIL 154 DISCOUNT VS 1AC 32 BALDOR RELIANCEP GV6000 AC Drives GV6000 Accessories ModelNumber Description TO Leng List RECBL M03 0 33 m 42 RECBL M10 F o 1 0m 47 RECBL M30 DPI cable male to male locking mini DIN converter to drive cable api 57 RECBL M90 9 0 m 83 RECBL F03 0 33 m 42 RECBL F10 i n f 1 0m 47 RECBL F30 DPI cable male to female locking mini DIN drive cable extension in 57 RECBL F90 9 0 m 83 DPI Screw Terminal Adapter Kit for extending remote OIM connections 1202 TB KIT SET up to 100 meters n a 120 Includes two screw terminal adapters DPI Screw Terminal Adapter Kit w Cable for extending remote OIM 1202 CBL KIT 100M connections up to 100 meters n a 364 Includes two screw terminal adapters tools and 100M shielded cable RECBL SSP 1 to 2 port DPI splitter cable n a 67 RECBL LCD OIM LCD external mount harness Hirose to DIN n a 52 RECOMM VSU232 VS Utilities and RECOMM 232 n a 437 m meters Note Drive DPI is a female mini din connector In order to connect to OIMs
92. rive mounted on frames 0 2 for low energy braking applications or mounted external for heavy duty braking applications e Braking Modes Extended deceleration ramp by frequency adjustment DC injection or Internal External DB Resistor 26 BALDOR RELIANCET OTHER FEATURES Configuration and monitoring of single or multiple drives when using optional V S Utilities PC Software Intelligent Thermal Management ITMTM system can reduce carrier frequency reduce current limit or shut the drive off in case of an over temperature condition UL and NEC approved electronic motor overload protection with motor OL memory upon removal of power from the drive 2005 NEC compliant Auto Restart with adjustable restart time and selectable number of restart attempts Frequency avoidance bands to lock out mechanical resonance points S curve acceleration and deceleration for smooth speed transitions Line to Line and Line to Ground output short circuit protection Fault memory logs the 16 most recent events with descriptive name fault number and timestamp Built in PID process control for automatically adjusting motor speed to precisely regulate external process variables Torque proving including flux up with brake proving float capability and micro positioning for lifting applications Sleep Wake mode provides the ability to start and stop the drive based on the level of an analog input rather than discrete start stop digital in
93. s Model Number Description Length List RECBL M03 0 33m 42 RECBL M10 DPI cable male to male locking mini DIN 1 0 m 47 RECBL M30 converter to drive cable 3 0 m 57 RECBL M90 9 0 m 83 RECBL F03 0 33 m 42 RECBL F10 DPI cable male to female locking mini 1 0 m 47 RECBL F30 DIN drive cable extension 3 0 m 57 RECBL F90 9 0m 83 DPI Screw Terminal Adapter Kit for extend 1202 TB KIT SET ing remote OIM connections up to 100 ia 120 meters Includes two screw terminal adapters DPI Screw Terminal Adapter Kit w Cable for extending remote OIM connections up to 2 CBL KIT 100M 100 meters n a 364 Includes two screw terminal adapters tools and 100M shielded cable RECBL SSP 1 to 2 port DPI splitter cable n a 67 RECBL LCD OIM LCD nu harness Hirose ia 52 RECBL SFC Serial flash cable converter to 9DSUB n a 57 RECOMM VSU232 VS Utilities and RECOMM 232 n a 437 DISCOUNT VS 1AC 23 BALDOR RELIANCEF SP600 AC Drives SP600 BRAKE RESISTOR SPECIFICATIONS The specifications below are applicable to external braking resistors The average power dissipation of the braking mode must be estimated and the power rating of the Dynamic Brake Resistor chosen to be greater than the average regenerative power dissipation of the drive Reference manual D2 3489 SP600 AC Drive Dynamic Braking Selection Guide for more detailed information Output Power Suggested Resistor Drive Rating Motor aai i Resistance Pe
94. selections overload protection possible e Adjustable Auto Restart Every SP600 is software selectable for either Analog Inputs 10 bit resolution e Frequency avoidance bands to lock out e Volts Hertz e Input 1 0 to 10 VDC or 4 20 mA mechanical resonance points e Sensorless Vector Control SVC e Input 2 10 to 10 VDC or 4 20 mA e S curve acceleration and deceleration for Analog Outputs 10 bit resolution smooth spega iransitiong Each method is capable of epprating single or 0 10 VDC 6SP models Line to Line and Line to Ground output short multiple motors from one AC Drive e 0 10 VDC or 4 20 mA 6SB models circuit protection l e Fault memory logs that display time stamped e Input Voltages Power Ratings Relay Outputs qty 2 Form C drive faults 200 208 240 0 5 to 25 HP e Braking Transistor Built in e Built in Pl process control functionality 380 400 415 480 0 5 to 200 HP Optional Drive mounted or externally 600 0 5 to 150 HP mounted braking resistor required Enclosures Mounting Braking Modes Extended ramp DC injection DB 1 SVC mode is limited to identical motors coupled mechanically 2 11 Bit resolutin and O 10 VDC on 6SB models 13 BALDOR RELIANCET QUIET MOTOR OPERATION UP TO 600 FT The SP600 controller uses IGBT transistors switched at frequencies up to 10 kHz to reduce PWM induced motor audible noise This technology limits the increase of audible motor to
95. sistor Sizing Data for GV3000 SE Bookshelf Drives with Built in Braking Transistor Maximum Braking Power and Permitted Braking Resistors GV3000 SF Maximum Drive Maximum Brak Resistor Minimum Braking Power Braking Power 31ER 31ET4060 460 750 720 6 Amps 125 4500 W 4500 W 38ER 38ET4060 460 750 720 6 Amps 125 4500 W 4500 W 55ER 55ET4060 460 750 720 6 Amps 125 4500 W 4500 W 85ER 85ET4060 460 750 720 6 Amps 125 4500 W 4500 W 126ER 126ET4060 460 750 720 10 Amps 75 7500 W 7500 W 150ER 150ET4060 460 750 720 10 Amps 75 7500 W 7500 W 240ER 240ET4060 460 750 720 15 Amps 50 11000 W 11000 W 300ER 300ET4060 460 750 720 20 Amps 37 5 15000 W 15000 W 430ER 430ET4060 460 750 720 30 Amps 25 22000 W 22000 W 1 The Turn on and Turn off voltages will be proportional to the incoming line power to the GV3000 SE Use the pre packaged Snubber Resistor Braking Kits in the table below or contact a local snubber resistor supply house for alternate size loose resistors for panel mounting Snubber Resistor Kit Sizing for GV3000 SE Bookshelf Snubber Resistor Kits can be connected to the GV3000 SE Bookshelf drive s built in braking transistor for dissipation of regenerative energy as heat By selecting the proper resistor the user can optimize the braking performance of the drive package Note Resistor maximum on rating is 60 seconds Model Number M3575RH5B Snubber Resistor Kit A Snubber Cabin et Dimen A 4 Resistor GV30
96. six times the NEMA motor inertia The kits are provided in a separate enclosure for field wiring SP500 SP500 Kit Model Resistor Style List Price Mult Voltage Hp Rating Number Wattage y Symb 460 15 20 2DB4020 1600 C 1 808 VSTAC BALDOR RELIANCEE GV3000 Vector Drive GV3000 AC DRIVES 1 thru 100 Hp 230 VAC 3 Phase 50 60 Hz 1 thru 400 Hp 460 VAC 3 Phase 50 60 Hz Applications Constant torque or constant horsepower applications New installations replacements and original equipment manufacturers OEM Features NEMA 1 NEMA 4 NEMA 12 IP20 and IPOO enclosures Output frequency O to 200 Hz with peak overload capacity of 150 Digital speed or torque control Built in PID process control loop Automatic tuning to motor and full rated torque down to zero speed Input Ratings Output Ratings Protective Voltage 230 460 Voltage Range 180 264 340 528 Phase 3 Phase Frequency 50 60 Hz 5 Impedance Line reactor needed for supplies with greater than 30 000 amp symmetrical fault capacity Horsepower 1 100 Hp 230VAC 3PH 1 400 Hp 460VAC 3 PH Overload Capacity Heavy Duty Constant Torque 150 for 60 seconds 200 for 3 seconds Normal Duty Variable Torque 110 for 60 seconds and 150 overload for 3 seconds Frequency 0 200 Hz Voltage 0 to maximum input voltage RMS Trip Microprocessor checksum over current over voltage under voltage over temperature motor or control output s
97. stance Dimensions Height Depth HE Inches mm inches mm 7 to 110A Weight Ibs kg Rated Output 18 79 477 3 10 65 270 5 12 23 310 6 58 Ib 26 4 55 BALDOR RELIANCEF FLEXPAK 3000 DC Drives FlexPak 3000 Power Module Style Drives 5 Three Phase DC Power Module Drive for Regenerative and Non Regenerative Applications from 5 to 400 Hp FlexPak 3000 Power Module drives can support 200 460 VAC line input voltages The customer must select and provide the appropriate fusing control transformer and contactor for the desired line input voltage Keypad Operator Interface Module OIM must be ordered separately Non Regenerative Power Module Hp Nom Unit Type Catalog Number Mult List at 460 VAC Current Rating c Current Rating cc Sym Price 29 50 60 50FN8742 VS50D 3 685 Regenerative Power Module 29 50 60 50FR8742 VS50D 4 080 125 208 250 200FR8742 VS50D 5 825 400 667 800 650FR8742 VS50D 11 525 a Hp based on 40 C ambient amp 460 VAC line input voltage at nominal rating Derate at 1 5 per C above 40 C 6 Nominal current rating is 100 continuous operation with 50 overload capability c Unit type current rating based on maximum continuous operation without overload d Field current regulator rating 4A 25 60A Ratings 10A 150 450A Ratings 12A 800A Rating Rating is based on unit type amp rating Note All ratings are based on 40 C Ambient Power Module S
98. tch 200V4160DS 200 150 240 360 200 150 240 264 32 940 VS1AC 250V4160DS 250 187 302 453 250 187 302 332 2 35 910 VS1AC 300V4160DS 300 224 361 541 5 300 224 361 397 1 42 653 VS1AC 350V4160DS 350 261 414 621 350 261 414 455 4 44 697 VS1AC 400V4160DS 400 298 477 525 400 298 477 525 48 469 VS1AC a Review dimension and application IO functionality for complete compatibility Contact your local district office for assistance b Model 75T4160 includes a built in RFI filter to meet CE component standards 38 BALDOR RELIANCEP GV3000 AC DRIVES GV3000 Closed Loop Vector NEMA 4 Enclosure Catalog Heavy Duty Mutt Number Hp Cont Amps _ Peak Amps ami AO 230 Volts Three Phase Input 2V2460 2 15 8 5 12 8 2 1 5 8 5 9 4 1 646 VS1AC VS1GV22 4B 3V2460 3 2 2 12 3 18 5 3 2 2 12 3 13 5 1 713 VS1AC VS1GV23 4B GV3000 Closed Loop Vector NEMA 12 Enclosure Catalo Heavy Duty Normal Duty List Mult Number Hp kW Cont Amps PeakAmps Hp kW Cont Amps PeakAmps Price Sym V S Alternate 230 Volts Three Phase Input 742260 7 5 5 6 26 9 40 4 7 5 5 6 26 9 29 6 2 231 VS1AC VS1GV27 4B 15V2260 15 11 53 3 80 15 11 53 3 58 6 3 738 VS1AC VS1GV215 4B 20V2260 20 15 69 6 104 4 20 15 69 6 76 6 4 611 VS1AC VS1GV220 1B 460 Volts Three Phase Input 15V4260 15 112 21 31 5 15 112 21 23 1 3 977 VS1AC VS1GV415 4B 20V4260 20 15 27 40 5 20 15 27 29 7 4 727 VS1AC VS1GV420 4B 60G4260 50 37 3 67 100 5 60
99. tyle Drive Options Mult Description Catalog Number List Price Sym Configuration Software CS3000 2CS3000 E8 418 Power Module Dimensions Hp Nom Current Unit Type Width Height Depth Weight at 460 VAC Rating Current Rating Inches mm Inches mm Inches mm Ibs kg 29 50 60 10 6 269 15 8 400 11 3 287 22 10 200 375 450 10 6 270 21 7 550 13 3 337 88 40 400 667 800 12 1 306 26 0 660 17 2 436 183 83 a Hp based on 40 C Ambient amp 460 VAC line input voltage at Nominal Rating Derate at 1 5 per C above 40 C b Nominal Current Rating is 100 continuous operation with 50 overload capability c Unit Type Current Rating based on maximum continuous operation without overload al O BALDOR RELIANCEF FLEXPAK 3000 DC Drives FlexPak 3000 Power Module Style Drives AC Line Disconnects for Chassis or NEMA Enclosed Drives Select and price disconnect per the table below This kit cannot be mounted on the FlexPak 3000 Power Module drives Incoming Line Voltage Disconnect For Chassis Drives Disconnect For Nema 1 Conversion Kit Mounting 230 VAC 460 VAC Catalog Number Mult Sym List Price Catalog Number Mult Sym List Price 1 1 2 25 3 50 901FK0101 902FK0101 400 30 60 901FK0201 40 60 75 125 901FK1102 75 150 901FK1202 901FK1212 2 175 100 200 90FK2101 125 150 250 300 901FK2201 400 901FK2401 50
Download Pdf Manuals
Related Search
Related Contents
INSTALLATION MANUAL Duct Type Series HP ENVY 5530 e-All-in-One Printer Setup Poster Bedienungsanleitungen GBC HighSpeed H215 Laminator Adresser une pétition au Parlement européen : mode d`emploi Vous Thermador WDC30E User's Manual Kathrein UFS 650si User's Manual BETRIEBSANLEITUNG USER MANUAL E 取扱説明書 Copyright © All rights reserved.
Failed to retrieve file