Concord LCD Keypad with 2-Way Voice Installation Sheet
Contents
1. The display should show BUS DEVICES 4 Press ES The display shows the lowest device address and its ID The following example shows what a device address display may look like UNIT ID 0 02110185 The 8 digit SuperBus ID number is also located on a label on the back of the keypad 5 Press F or v to cycle through all bus device addresses until the keypad appears 6 After verifying the keypad device ID press repeatedly until the display shows SYSTEM PROGRAMMING 7 Press ES v until the display shows EXIT PROGRAMMING READY then press The keypad should show the date and time display Programming To program options for the newly installed keypad such as key beeps see the specific panel Installation Instructions Connecting the Keypad for System Programming Only For installations that don t include an alphanumeric keypad as a permanent part of the system connect one for system programming to the Programming Keypad Header on the panel To do this first connect a Programming Keypad Cable 60 791 to the keypad wires See the Programming Keypad Cable Installation Instructions P N 466 1604 included with the cable Then use the appropriate procedure for connecting the keypad To connect a programming keypad to a Concord 4 panel 1 With the panel powered up connect the cable to the Programming Keypad Header Pins See Figure 10 below Concord LCD Keypad with 2 Way Voice Installation Sheet Fig
2. Remove the two small flathead screws that attach the terminal block plate to the mounting plate 2 Mount according to the process above Note Tamper screws must be installed into a stud Wiring the Keypad A NCAUTION Use static electricity precautions when handling electronic components Utiliser les pr cautions de l lectricite statique lors de la manipulation des composants lectroniques 1 Remove the panel AC and backup battery power 2 Run wires 18 or 22 gauge from the panel and sensor to the keypad location e 4 conductor no 2 way voice between panel and keypad e 8 conductor with 2 way voice between panel and keypad Note Interlogix recommends using shielded cable to prevent crosstalk between the speaker and microphone 2 conductor to sensor between keypad and hardwire sensor if installed 3 When routing the wires route all wiring connections from the access area directly to the terminal keeping wires short and flat No loops of wire should run outside the access area Note Do not run any excess wire outside the access area as it will make the assembly of the keypad onto the mounting plate difficult Wiring the Keypad SB2000 1 Pull the ground 12 volt and bus wires through the access area 2 Connect the Bus to the 9 position terminal block as shown in Figure 3 below Figure 3 Connecting the Keypad D Note For bus wire length over 150 feet a 120 ohm te
3. e seulement aux conditions suivantes 1 ilne doit pasproduire de brouillage et 2 l utilisateur du dispositif doit tre pr t a accepter tout brouillage radio lectrique re u m me si ce brouillage est susceptible de compromettre le fonctionnement du dispositif Contact Information For general information see www interlogix com For customer technical support see www interlogix com customer support or call 1 855 286 8889 2015 United Technologies Corporation Interlogix is part of UTC Building and Industrial Systems a unit of United Technologies Corporation All rights reserved Limitation of Liability To the maximum extent permitted by applicable law in no event will Interlogix be liable for any lost profits or business opportunities loss of use business interruption loss of data or any other indirect special incidental or consequential Concord LCD Keypad with 2 Way Voice Installation Sheet damages under any theory of liability whether based in contract tort negligence product liability or otherwise Because some jurisdictions do not allow the exclusion or limitation of liability for consequential or incidental damages the preceding limitation may not apply to you In any event the total liability of Interlogix shall not exceed the purchase price of the product The foregoing limitation will apply to the maximum extent permitted by applicable law regardless of whether Interlogix has been advised of th
4. q 1 elduuoO P SYN sed APEL gg z 99r in lesiiin i P EPIND g2 99r uonellelsui p OPNO ulpui9s anbeyy IWJS S 3170A Z891S8l y D103u09 339Ap 3B5esn uno 9 9 Concord LCD Keypad with 2 Way Voice Installation Sheet
5. ashes the entered selection then stops after pressing and displays the new setting and brightness level 9 9 6 Exit user programming mode Status LEDs The keypad has LEDs that indicate the current system status at a glance Table 6 below explains LED behavior Table 6 Status LEDs LED System status Solid blue while backlights are on Solid red while backlights are on System is disarmed status is normal System armed Flashing red System is in alarm Flashing blue System is disarmed trouble or alarm condition present for example protest low battery supervisory bus trouble tamper open zone etc Note Solid status LEDs display only when a key is pressed or backlighting is on Flashing LEDs remain flashing until the fault or alarm condition is cleared Door and Hinge Removal 1 Remove the keypad from the mounting plate 2 Using a screwdriver back out the hinge retainer screws 1 8 See Figure 11 3 Remove the door and hinges Note Per SIA CP 01 2010 requirements the door must remain attached and closed during normal operation Figure 11 Door and Hinge Removal Hinge Retainer Screws 6 9 Troubleshooting Problem Action Solution Keypad doesn t power Check for correct wiring connections at up no display and no keypad and panel terminals beeps when keys are Make sure panel battery is connected pressed correctly and that the panel transformer is plugged in Make sur
6. e panel transformer is not plugged into an electrical outlet controlled by a switch Relocate transformer to an unswitched outlet location if necessary Keypad status blue LED is flashing and a trouble star is displayed on the LCD indicating a trouble condition and system doesn t respond to commands from keypad Check for correct bus wiring connections green and white wires at keypad and panel terminals No sound coming from Check for correct wiring connections at speakers keypad and panel terminals Specifications Compatibility Concord 4 12 VDC nominal Maximum alarm current Power requirements Current 110 mA Current 60 mA Current 23 mA Power saving mode no panel AC power Operating temperature 32 to 120 F 0 to 49 C 4 to 140 F 20 to 60 C 95 relative non condensing 5 32 x 6 03 x 092 L x W x D Typical operation Storage temperature Humidity Dimensions Regulatory Information Manufacturer UTC Fire amp Security Americas Corporation Inc 1275 Red Fox Rd Arden Hills MN 55112 6948 USA UL listings UL 985 Household Fire Warning System Units UL 1023 Household Burglar Alarm System Units UL1610 Central Station Burglar Alarm Units Commercial Burglary Note See specific panel nstallation Instructions for complete UL installation requirements Not investigated by UL for use as a medical alert Concord LCD Keypad with 2 Way Voice Installation Sheet FCC Part 15 Info
7. e possibility of such damages and regardless of whether any remedy fails of its essential purpose Installation in accordance with this manual applicable codes and the instructions of the authority having jurisdiction is mandatory While every precaution has been taken during the preparation of this manual to ensure the accuracy of its contents Interlogix assumes no responsibility for errors or omissions 7 9 Installer Please provide this page to the end user 8 9 Concord LCD Keypad with 2 Way Voice Installation Sheet CN co sr tO OR oc s uoz s p suondiuo5s dq 0 0 ns 13 nddy 99 O11UOO SOJBILUN SO JOLWIO4 JOWINI V 7 Jns JaAnddy Z OWAISAS 9 JOWUESIQ UO UCD 9 JOAIOeS9G NO JEAIOY QUOZ p ap OJAWNU 9 3009 ns Jaknddy Z 4 dw09 NO llupd BWAISAS JOWIY uoz 9UN JOUINOJUOY 3009 19 dui02 no uns JeAnddy Z m O gt epidey alos JOUINOWUOD S IUNT je O I Od ZAXM ANL sud 6q 3009 awuesaq no uns J nddv G B F wejy un 1 nuuv nuayy UU IS S Speil 3009 uups 0 no uns JaAnddy e 7 elap e apod aun Jed JOS or XNIIDUaIIS 1ejaq SULS 9J 9U9 9 SALOd d 9 NO 19W34 430 gay o 19 duioo JOU G L up1up sul SAOd s 9IDU9J Inod y J9 duuoo see JEW ne Ins JaAndde ajjatued aunjyawwe uy Lo 3009 ajjamed no z ins JeAnddy EJ EJ EJ S 119u9 19 S8UOd 9 19W94 V wv ayaed Joy uuges
8. en volume will be reduced if connected in series This information differs from the information listed in the Concord 4 Installation Manual e Do not exceed the maximum available power given in the panel installation instructions P N 466 4434 REV H 13FEB15 e The hardwire zone is intended for use with intrusion sensors only This zone input does not provide power for sensors such as PIRs fire detectors etc e Up to 16 keypads can be installed on a Concord 4 system of which a maximum of two can be connected to two way audio or a single keypad plus an audio verification module Table 1 Keypad Power Usage Current mA Conditions 110 Maximum alarm current with the buzzer sounding and the keypad illuminated from a button press 60 Typical operation 23 Power saving mode no panel AC power Table 2 Maximum SuperBus and Audio Wire Lengths Wire gauge unshielded or Max keypad wire length between shielded keypad and panel 18 750 feet 22 300 feet Note Interlogix recommends using shielded cable to prevent crosstalk between the speaker and microphone Table 3 Maximum Hardwire Zone Wire Lengths Wire gauge unshielded or Max keypad zone wire length shielded between keypad and sensor 22 100 feet Hardwire zone End of Line EOL resistor should be 2K ohm Installing the Mounting Plate 1 Place the keypad on a flat surface so that the mounting plate is facing as shown in Figure 1 on page 2 2 Remove the mountin
9. end of line EOL resistor at the last device in the loop See Figure 7 below Note The EOL resistor must be located at the last device in the loop 4 Use a maximum of five contacts Note The keypad does not supply power for sensors Sensor Zones must be of the normally open or closed contact type Figure 7 Hardwire Zone Normally Closed NC Contacts EOL Resistor x y Rohm N N Normally Open NO Contacts EOL Resistor 2K ohm 3 9 External Contact Wiring Table 4 External switches Normally closed Normally open Open Tamper Short Alarm Short Tamper 2K ohm Normal Open Alarm 2K ohm Normal Note A bus failure will result in a zone trouble condition Attaching the Keypad to the Mounting Plate 1 Align the right side of the keypad over the hooks on the mounting plate See Figure 8 below 2 Swing the left side of the keypad over the latches on the mounting plate until the latches snap into place See Figure 8 below Figure 8 Attaching the Keypad to the Mounting Plate Note To remove depress both latches on the left side and then swing the left side of keypad away from the wall removing the keypad from the hooks Applying Decals A set of decals is included with the keypad for labeling the function keys For Concord 4 the function keys are programmed Fire F1 Auxiliary F2 and Police F3 Carefully apply the function key decals as needed on the keypad as s
10. g plate from the keypad as described in Figure 1 on page 2 Figure 1 Removing Mounting Plate From Keypad Place an index finger on each latch Place left thumb in the Wire Access Area underneath the cover Place right thumb in the Wire Access Area underneath the cover Depress latches with index fingers When latches release use thumbs to lift the mounting plate away from the keypad 3 Place the mounting plate on the wall and mark the primary and tamper mounting holes making sure to leave a 6 inch clearance below the keypad for the door to open See Figure 2 below Note Gang box mounting screws are not provided with this keypad 4 Insert anchors into the wall at the marked locations where studs are not present 5 Align the mounting plate over the selected mounting locations and secure the back plate using the screws provided Note Do not over tighten screws or the mounting plate may bind and prevent the keypad from mounting properly Figure 2 Marking the Mounting Holes Primary Wall Mounting Holes gt Ox mme Fo O O g An 7 S Tamper Wire Gang Box Mounting access D Screw Holes 6 Holes A Primary Wall Mounting Holes 6 Cuta hole in the wall at the wire access area of the mounting plate to pull the wiring cable through Optional Tamper Mounting Note Tamper mounting hardware is not supplied with this product To enable the tamper function 1
11. hown in Figure 9 below Figure 9 Function Key Decals Please refer to Table 5 below or to the specific panel installation user manual for more information on when specific key presses are required Note The Auxiliary Alarm Key is not evaluated for and not to be used for UL 1637 medical applications Table 5 Key Functions Key Function Scroll through available options at current menu A vy tier Enter pauses when programming telephone numbers no end user function Delete certain program settings Also used as Quick Exit key for end user Power up and Bus Communication Follow the steps below for powering up the panel and for verifying that the keypad and the panel are properly communicating with each other Note Upon power up the panel scans the bus for connected devices assigns a unit number to each bus device and automatically learns the device ID number of each bus device 1 Verify that all wiring between the panel and keypad is correct 2 Connect the panel battery and restore AC power Alphanumeric keypads briefly show SCANNING BUS DEVICES then displays date and time Optional steps 1 through 7 1 Atthe keypad enter program mode by pressing 8 installer dealer code default 4321 0 0 The keypad should display SYSTEM PROGRAMMING Concord LCD Keypad with 2 Way Voice Installation Sheet 2 Press A T isplay should show SECURITY 3 Press or unti display shows ACCESSORY MODULES then press
12. interlogix Concord LCD Keypad with 2 Way Voice Installation Sheet Description The Concord LCD Keypad with 2 Way Voice provides control of all programming and operation of compatible security systems The 2 line 16 character display provides easy to read messages to indicate the current status of the system The keypad includes police fire and auxiliary panic buttons that can be activated anytime An internal piezo provides system status beeps for trouble and alarm indications Two way audio is achieved using an internal speaker and microphone combination A supervised hardwire zone provides an additional zone without added wiring to the panel Opening the removable swing down door reveals a label with basic system operating commands Not UL approved as a primary annunciator Not investigated for use as two way verification Tools and Equipment needed 4 conductor 18 or 22 gauge wire e 2 Phillips screwdriver e 6 screws and anchors included e Screws for gang box installation e Saw or utility knife for cutting wallboard Installation Installation Guidelines e Mount the keypad in an environmentally controlled area 32 F to 120 F 0 C to 49 C e When mounting the keypad allow at least 6 inches below it for the swing down cover When connecting two way voice to the keypad any additional speaker devices on the system should be connected in parallel with the keypad speaker connection Note Sir
13. rmation to the User Changes or modifications not expressly approved by Interlogix can void the user s authority to operate the equipment FCC Part 15 Class B This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against interference in a residential installation FCC compliance This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the affected equipment and the panel receiver to separate outlets on different branch circuits I Consult the dealer or an experienced radio TV technician for help This Class B digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe B est conforme la norme NMB 003 du Canada L utilisation de ce dispositif est autoris
14. rmination resistor is needed across A to B at the panel Concord LCD Keypad with 2 Way Voice Installation Sheet Wiring the Keypad Speaker and Microphone 1 Pull the speaker and microphone wires through the access area 2 Connect the speaker and microphone wires to the 9 position terminal block as shown in Figure 4 below Figure 5 below and Figure 6 below 3 If other audio devices will be installed on the system wire accordingly as shown in the following diagrams Note 1 Interlogix recommends using shielded cable to prevent crosstalk between the speaker and microphone Note 2 The keypad is not UL approved as a primary annunciator Note 3 Installations requiring an AVM in addition to the Keypad Audio require the addition of a 10 K ohm resistor included on the MIC wire of the AVM to equalize the MIC performance of both devices Figure 4 Keypad to Audio Diagram keypad only Speaker L Speaker Keypad 2 if installed Figure 5 Keypad to Audio Diagram multiple speakers External Speaker Concord LCD Keypad with 2 Way Voice Installation Sheet Figure 6 Keypad to Audio Diagram with Audio Verification Module y Speaker CN s Speaker 5 600 1070 Speaker Mic AVM 60 677 Wiring the Keypad Hardwire Zone 1 Pull the hardwire zone wires through the access area 2 Connect the hardwire zone wires to the 9 position terminal block as shown in Figure 7 below 3 Insert the
15. ure 10 Connecting a Programming Keypad Concord 4 O Programming Keypad O Header Pins 2 Activate the keypad by pressing installer dealer CODE EB EN 3 Enter program mode by pressing installer dealer CODE E and program the panel using the panel Installation Instructions 4 When programming is completed disconnect the programming keypad Testing Note Contact the central monitoring station before activating alarms to avoid dispatching local police and fire departments Test the keypad by arming disarming the system activating the keypad panics bypassing sensors and by turning chime and lights on off to verify correct operation Refer to the panel Users Manual for complete system operating instructions Adjusting Display Brightness The keypad display can be adjusted for easier viewing to help compensate for lighting conditions in the keypad location The brightness adjustment lightens or darkens the background To adjust display brightness 1 Enter user programming mode by pressing 9 user partition or system master CODE The display shows SYSTEM MENU then TIME AND DATE 2 Press v until the display shows OPTIONS then press The display should show DOWNLOADING ON OFF current setting 3 Press RQ twice The display should show KEYPAD BRIGHTNESS 2 default setting 4 Enter a setting from 0 darkest background to 3 brightest background then press ES 5 The display fl