Getting started with x 3
Contents
1. please ensure you state your Network OWL MAC ID 2 Save Energy Limited operate a policy of continuous development and improvement therefore the content of this document is subject to change without notice Document Version 3 0 August 2014 16 2 Save Energy Limited 2014
2. and password at https www owlintuition com e You should now have an Electricity and 3 Phase widget within your web dashboard e If you watch these new widgets you should see the live total consumption in the Elec tricity widget and live individual phase consumption in the 3 Phase widget updating every 12 to 60 seconds e Check the signal strength of the radio signal between your Transmitter and Network OWL Signal strength indicator Settings icon 2 Save Energy Limited 2014 9 e Ifthe signal strength is only 1 or 2 bars to reduce the chance of intermittent inconsistent data reception it is suggested that you reposition the Network OWL so that it is physically closer to the Transmitter e The Network OWL should ideally be hung on the wall in a free area as far from large metal objects as possible Position the antenna in a vertical orientation e If necessary you can replace the Ethernet cable with a longer cable up to 100 meters long If installing a long Ethernet cable is a problem you can use a Powerline Range Extender or Wireless Range Extender please search for these common products online For details on using your new OWL Intuition Ic system please now download the Elec tricity Monitoring User Manual document by clicking on Manuals on the web dashboard lower right Please ensure you retain this document for future reference 10 2 Save Energy Limited 2014 TNTORTATION amp TROUBLE SHOOTING
3. Network OWL is online Ensure successful account creation completion message is displayed STEP THREE Log in and follow Wizard Log in to the OWL Intuition account with username and password If this is a new system the installa tion amp configuration Wizard will auto matically open For existing Intuition installations you should start the Wizard by clicking the Wizard menu bar option at the top of the screen Select Electricity Solar Monitoring from the drop down box Click the Start button and follow OWL Intuition Configuration Wizard Introduction Please use this wizard to ADD new monitoring or control elements to your system Please select an appropriate option below then click Start or click Finish once all devices have been set up Electricity Solar Monitoring 2 Save Energy Limited 2014 the Wizard through these steps e Select Electricity Transmitter type as CMR180i and click Next e Slide back cover off of the Transmitter and insert the batteries into the unit e Press the small Check button in the Transmitter bat tery compartment until the red LED on the front starts flashing e The Transmitter is now in Pairing Check Mode and the red LED on the front will start flashing every 2 sec onds for 30 seconds Click the Wizard Next button IMPORTANT Pairing Notes e Please DO NOT remove the Transmitter batter ies once fitted or the pairing will be los
4. Remove the batteries before storing the product for extended periods e Only use fresh batteries Do not mix new and old batteries e Do not dispose of old batteries as unsorted municipal waste only do so in accordance with your local waste disposal regulations e When disposing of this product do so in accordance with your local waste disposal regulations CARING FOR YOUR PRODUCT e Before cleaning disconnect the Sensor and remove the batteries from the Transmitter e Usea lightly dampened cloth Do not use liquid or aerosol cleaning agents benzene thinners abrasive or corrosive materials Do not scratch hard objects against the product Do not leave discharged batteries in the product 2 Save Energy Limited 2014 13 SPECIFICATIONS COMPLIANCE The CE marking certifies that this product meets the main requirements of the European Parliament and Council Directive 1999 5 EC A copy of the signed and dated Declaration of Conformity is available on request OWL Intuition products are manufactured to ISO 9001 Quality Assurance Standards 14 2 Save Energy Limited 2014 WARRANTY INFORMATION 2 Save Energy Limited guarantees that OWL Intuition products will work for a minimum period of 24 months from date of purchase and that it will be free from defects in materials workmanship or design If during this limited 2 year period of guarantee from date of purchase you find that the equipment is not working properly you may return
5. TIPS Unless the Transmitter is in Check Mode the red LED does not flash in order to pro long battery life e Check that the blue LED on the Network OWL flashes at least every 12 seconds if the monitored electricity supply consumption is varying or every 60 seconds when at a steady state e For wireless range testing you can make the Transmitter send its signal every 2 sec onds for 30 seconds by pressing the Check button in the battery compartment for 10 seconds The red LED will flash with each transmission the Network OWL blue LED will flash to confirm the signal has been received e Ifthe blue LED does not flash then the Transmitter signal is not being received or the Transmitter Pairing has been lost e On the web dashboard click on the Devices menu then click on Electricity Transmitter If the Last Reported time is greater than 60 seconds then it is likely the batteries have been removed from the Transmitter since pairing Click on the Change Batteries button and follow the instructions provided e If necessary undo the Transmitter s Sensors and move it so it is close to the Net work OWL Repeat step above to confirm if radio range is an issue e Battery change when the Transmitter batteries require replacement the battery icon on the Electricity widget will change to red Use web dashboard Devices menu Electricity Transmitter Change Batteries feature to ensure that pairing is not lost 2 Save Energy Lim
6. it to us and we will replace or at our discretion repair it free of charge 2 Save Energy Limited will not accept any liability for defects arising from fair wear and tear accidental or wilful damage misuse or failure to follow product or safety instructions If you return any equipment as faulty 2 Save Energy Limited reserves the right to test the equipment and if found to be in perfect working order to return it to you In this event 2 Save Energy Limited reserves the right to charge for any testing or postage costs incurred This does not affect your legal rights relating to equipment which is faulty Warranty conditions only apply where Proof of Purchase is provided To return your OWL Intuition product please contact customer services theowl com to report the issue and your reason for wishing to return your product 2 Save Energy Limited will issue you an RMA number You should ensure that the returned product is clearly marked with the issued RMA number Once we have received the product and proof of purchase we will commence the returns process 2 Save Energy Limited 2014 15 For details on using your new OWL Intuition Ic system please download the Electricity Monitoring User Manual document by clicking on Manuals on the web dashboard lower right Customer Support If you have any further questions please check our knowledge base at https theowl zendesk com You can also email us at customer services theowl com
7. Getting started with OWE Untuition tc Electricity consumption monitoring three phase for larger homes and light commercial premises IN THE BOX 3 x plug in standard 3x AA Sensor clamp alkaline battery lt 10mm cable lt 71A OR 3 x plug in large Sensor clamp C lt 17mm cable lt 200A rs Transmitter unit 3 channel 2 Save Energy Limited 2014 Introduction This Electricity Transmitter is a part of the OWL Intuition range of cloud connected moni toring and control products Its operation is dependant upon being paired to the broad band Internet connected Network OWL supplied separately This version of the Electricity Transmitter is designed for monitoring three phase electric ity consumption It is suitable for use in larger homes and some smaller light commercial premises Access to both live and historic energy information collected by this Transmitter is via the OWL Intuition web dashboard from any Internet connected computer anywhere in the World iPhone and Android smartphone apps are also available for free download For details on using your new OWL Intuition Ic system please download the Electricity Monitoring User Manual document by clicking on Manuals on the web dashboard lower right 2 2 Save Energy Limited 2014 Installation Instructions STEP ONE Install Network OWL e If you are adding 3 Phase electricity monitoring to an existing Intuition installati
8. TANT e You must ensure that each Sensor is ONLY around the live core and NOT around a sheathed cable containing live neutral and earth e The Sensors must be a loose fit onto the cables e After the Sensors have been installed the Transmitter should be hung on the wall in a free area as far from large metal objects as possible e Locate the supply cables between your electricity meter and mains distribution board 6 2 Save Energy Limited 2014 fuse box See diagram on page 8 e Using the latch clamp the 3 Sensors around the insulated Live cables going into the meter as per the table below Live cables either side of meter is acceptable Phase Line IEC 60446 Pre 2004 OWL Transmitter Number Wire Colour IEE Colour Socket 2 Save Energy Limited 2014 7 Industrial Loads Ring Mains Lights Machines etc Transmitter Fuse Box ec D Distribution Board RY XQ A 2E BE Fi iaaa A P2 L2 lq a Sensor HSEEE P3 L3 EE Sensor Neutral P1 L1 P2 L2 P3 Ls Utility Meter Blue Brown Black Grey Alternative 4 Sensor Locations _ _ Intuition Ic Electricity Grid Transmitter amp Sensor Installation 2 Save Energy Limited 2014 STEP FIVE Log in to your OWL Intuition account If you are not already please log in to your OWL Intuition account with your username
9. ited 2014 11 SAFETY INFORMATION To ensure that you use your product safely and correctly please read the warnings amp safety precautions below before installing your OWL Intuition Transmitter amp Sensor This product uses a Type C current Sensor Do not apply around or remove from haz ardous LIVE conductors When fitting the Sensor if in any doubt always contact a qualified electrician Do not immerse the unit in water or other liquids If you spill liquid over it dry it im mediately with a soft cloth Do not use or store the product in conditions that could adversely affect the product such as rain snow desert and magnetic fields Do not subject the product to excessive force shock dust temperature or humidity Keep the product away from heat sources radiators stoves heaters etc Do not use the product in or near water or in high moisture areas such as bathrooms Do not tamper with the product s internal components This invalidates the warranty Do not attempt to repair the product yourself Contact the retailer or Customer Services if your product requires servicing If the equipment is used in a manner not specified in this manual the protection pro vided by the equipment may be impaired Take care when handling all battery types Batteries can cause injuries burns or dam age to property if they come into contact with conducting materials heat corrosive 2 Save Energy Limited 2014 materials or explosives e
10. on then please jump to STEP THREE Log in and follow Wizard e If this is a new Intuition installation then you will first need to install the Network OWL supplied separately For full details please refer to the Network OWL installation guide supplied with that product however a summary of the steps are listed below 1 Connect Ethernet cable between spare active LAN port on your broadband Inter net router and the Network OWL 2 Plug the power supply into the mains and insert the DC jack connector into the base of the Network OWL 3 Wait until the green LED on the top of the Network OWL is flashing with a triple blip pattern This should not normally take longer than 2 minutes 4 Do NOT proceed to STEP TWO until this flashing pattern is observed STEP TWO Create Intuition online account e If you are adding 3 Phase electricity monitoring to an existing Intuition installation then please jump to STEP THREE Log in and follow Wizard e If this is a new Intuition installation then you will first need to create a new OWL 2 Save Energy Limited 2014 3 Intuition account For full details please refer to the Network OWL installation guide supplied with that product however a summary of the steps are listed below Click Create Account Fill in the information requested Click Create Account button Oy GT A O N E Using a web browser visit https www owlintuition com Check and confirm that the
11. t PRESS e You can quickly check for correct pairing at any time CHECK BUTTON by pressing the Transmitter Check button until the red LED starts flashing if the Transmitter red LED and Network OWL blue LED flash within a fraction of a second of each other they are correctly paired e When the Pairing Successful message is displayed in the Wizard click Next e Select Electricity Monitoring System type as Intuition Ic 3 phase electricity and click Next ZE MADE IN CHINA 2 Save Energy Limited 2014 5 e Adjust consumption Voltage and Power Factor settings to measured values if available If in doubt leave the default values Voltage 230 Power Factor 1 0 and click Next Please note that this voltage is the phase to neutral voltage and is hence 230V rather than 400V phase to phase voltage e Ensure message Device successfully added to your Intuition system is displayed e Click the Finish button e Unless you have further Intuition devices to install configure then click the Finish button e Click the OK button to close the Wizard The web dashboard will then automatically refresh itself and you should now have an Electricity and a 3 Phase Electricity widget within the web dashboard although the live readings will be zero at this stage until the Sensors are correctly attached in the next step STEP FOUR Install Transmitter and attach Sensors IMPOR