Opman SRL2 v30.qxd - Fieldpiece Instruments

image

Contents

1. The sensor detects changes in concentration not absolute con centration making it easy to detect leaks even in areas with refrigerant in the air The SRL2 detects leaks as small as 0 1 oz year which exceeds the toughest SAE J1627 standards The SRL2 comes with wall and car charger for its ultra compact Lithium ion battery which powers the SRL2 for 8hrs of continuous operation before a recharge is needed That s long enough to last your entire workday Unlike many leak detectors oil vapor does not trigger the SRL2 The SRL2 has vari able sensitivity set tings keeping nui sance tripping to a minimum A quick and automatic 30 second self calibration upon power up ensures optimal performance A built in replaceable filter blocks moisture and harmful particulates The SRL2 also has a mute button and a peak hold func tion Turning the PEAK function off will clear the peak change The PEAK LED will light wnen PEAK func tion is on Turbo Mode The TURBO function is an additional 4th sensitiv ity that pushes the SRL2 to it highest possible sen sitivity This feature is activated by pressing the PEAK button four times in succession and can only be activated while on the high H sensitivity level When in the TURBO mode the first green LED on SRL2 will strobe and the audio detection sound will be a solid tone To exit the TURBO mode press the PEAK button again four times in succession or switch from high H to one of
2. to 140 F 60 C less than 1 month 4 F 20 C to 113 F 45 C less than 3 months 4 F 20 C to 68 F 20 C less than 1 year Charging Two chargers are included with the SRL2 The AC charger plugs into a wall outlet and the car charger plugs into a car cigarette lighter DC plug 1 The battery is partially charged when packaged Fully charge the battery before first use 2 The LOW BATT LED will light red when the bat tery is low Charge can be checked at any time the unit is on with the Battery Check function See Operation section 3 To recharge the SRL2 plug one end of the charger into the top of the SRL2 and the other into the power source LOW BATT will blink while charging until the battery is fully charged When the SRL2 battery is fully charged LOW BATT turns off 4 Charge within operating environment specified in the Specifications section in this manual 5 Avoid frequent full discharges Several partial discharges with frequent recharges are better for lithium ion batteries Unlike nickel based bat teries they have no charge memory and do not need to be discharged before charging Storage The battery should have a 40 50 charge dur ing prolonged storage of a month or longer See Specifications section in this manual for proper stor age environment Battery life is dramatically reduced if the battery is stored fully charged and or at high temperatures Patents 6 791 088 and 7 022 993 Not
3. Infrared Refrigerant Leak Detector Model SRL2 Refrigerant Leak Detector a gt Fieldpiece Paasi _ _ hie Fieldpi ce NAY OPERATOR S MANUAL Operation ON OFF Protection To turn on off the SRL2 press and hold the ON OFF button for one second This slight delay protects against inadvertent pressing If you forget to turn it off it will automatically go off in 10 minutes LED Bar Graph Display The eight segment LED display indicates the degree of change in refrigerant concentration As the concentration of refrigerant in the air increases so does the number of lit bars on the display L M H Button Sensitivity Set the sensitivity level by pressing the L M H but ton Low L medium M or high H sensitivity will be indicated by their respective LED The higher the concentration of refrigerant in the ambient air the lower the sensitivity setting should be to minimize false trips Mute Button Pressing the MUTE button toggles the sound of the SRL2 off and on Peak Button The PEAK function holds the highest change in concentration achieved while continuing to detect leaks Press PEAK to toggle this function on and off Description The SRL2 uses infrared optics to create a portable refrigerant leak detector technology that has a superior combination of sensitivity speed sensor life battery life portability and ease of use Gas is pumped through the tip of the wand into the sensor within the SRL2 body
4. er meter is attached to it Heads can attach directly to the top of a Stick meter DL2 data logger or EHDL1 They can also plug into any meter with mV ranges using ASLS2 leads Warranty and Service The product is warranted to the original purchas er against defects in material or workmanship for a period of one 1 year from the date of purchase During the warranty period Fieldpiece Instruments will at its option replace or repair the defective unit This warranty does not apply to defects resulting from abuse neglect accident unauthorized repair alteration or unreasonable use of the instrument Any implied warranty arising out of the sale of Fieldpiece s products including but not limited to implied warranties of merchantability and fitness for purpose are limited to the above Fieldpiece shall not be liable for incidental or consequential dam ages Return any defective SRL2 to Fieldpiece for war ranty service along with proof of purchase Contact Fieldpiece for out of warranty repair charges Fieldpiece Designed in USA MADE IN TAIWAN v30
5. ges in cross section or direction of these lines The SRL2 detects changes in concentration of refrigerant not the absolute concentration of refrig erant This lets the user easily detect leaks in places that may have refrigerant in the air such as a refrig erator leaking into an enclosed space Because the SRL2 detects change there is a specific double pass method used to find leaks 1 The tip of the wand should be fairly close to the line You may need to be within 1 4 0 63cm of a small leak to detect it In this case using a second hand to guide the tip along refrigerant lines may be helpful 2 Keep the tip moving along refrigerant lines at a rate of 1 3 inches per second 3 Once the SRL2 indicates a change in concentra tion note the spot on the line and keep the tip moving past the potential leak to refresh the air space within the SRL2 with clean air Note If the SRL2 wand moves through a very high con centration of refrigerant you may need to use in fresh air for 4 seconds before moving to step 4 in order to clear the refrigerant within the SRL2 Comparing Leak Detectors Fieldpiece has two leak detectors The SRL2 uses an infrared IR sensor It detects a CHANGE in concentration so the wand must keep moving The main advantages of the Fieldpiece IR sensor are that its sensitivity will remain the same over the life of the instrument the sensor will last the lifetime of the instru ment it will not tr
6. ice of Compliance This instrument complies with the specifications for an indicating locating leak detector as described by the european standard EN 14624 EN 14624 2005 with the assumption that the speed specification in section 7 2 should read as 2 0 cm s as was indicated to us by A Beatrix Alke project manager of Deutsches Institut fur Normung Included Equipment Use model RRE2 when detecting in tight spaces such as through a condenser grille Model RFE2 extends the wand to 25 5 65cm The blow mold ed case model holds accessories and chargers All accessories shown are included with the SR2K7 9 23cm Flex Extension model RFE2 Blow molded Carrying Case w RRE2 and RFE2 Model ABMK3 9 23cm Needle Tip Probe model RRE2 More Products From Fieldpiece Modular Expandability Modular expandability is ability for accessory heads and meters to change configurations to match the various needs of an HVAC R technician Accessory heads the sensors send out a mV signal which represents the value of the measure Standalones from Fieldpiece The SRL2 refrigerant leak detector is designed for HVAC R technicians Here are some other standalone products from Fieldpiece Instruments SRH2 Diagnostic Psychrometer aes Fieldpiece Hisa l Temperature TAD SSX34 aeaa SC77 Superheat and i a All in one ubcooling for Expandable and Refrigeration Clamp on Meter ment to whatev
7. igger on humidity or on oil and it has nearly the same sensitivity to most refrigerants The main disadvantage of infrared sensors is their sensitivity to mechanical disturbances The SRL8 uses a heated diode sensor The heated diode sadvantage is that it detects absolute concentration levels so it can be held on a leak and will continue to beep It is also initially very sensitive lts disadvantages are that the sensor becomes less sensitive over life eventually needing replacement and it is more sensitive to some refrigerants than others 4 Return the tip back to and past the spot first indicated When the SRL2 indicates a second change note the spot on the line The source of the leak will be near the midpoint between the two noted spots of indication 5 Very high concentrations of refrigerant can cause an overload which can take a few sec onds to clear j ii od SRL2 testing an A coil in an evaporator 1 4 from the line Lithium Battery Care The SRL2 contains a very powerful lithium ion battery For a long battery life and safe operation you must observe the following Cautions 1 Do not expose the battery to temperatures high er than 140 F 60 C 2 Do not charge the battery in or nearby heated places such as fire hot vehicles or direct sun light 3 Do not solder directly on battery 4 Do not expose the battery to direct impact or throw it Do not get the battery wet Do not deform o
8. r pierce the battery in any way If there is any battery leakage do not touch the battery In the case that electrolyte gets into the eyes flush with fresh water do not rub and see a physician immediately 8 Replace immediately if there is any deformity bad smell color change or other abnormality 9 The battery is not user replaceable if the bat tery fail contact Fieldpiece for replacement N OI Specifications Sensing element Enhanced infrared photo optics Sensor life 10 years Refrigerants HFC CFC HCFC and blends Sensitivity Min Stationary 0 10z yr 3g yr Max Stationary gt 1 050z yr gt 30g yr Min In motion 0 1802 yr 5g yr Max In motion gt 1 050z yr gt 30 g yr After exposure to 50g yr 0 1 oz yr 3g yr In poluted environment 0 1 oz yr 3g yr Response time 1 second Recovery time 4 seconds Auto off 10 minutes after no activity Battery 7 4VDC nominal rechargeable lithium ion technician replaceable battery Battery life 8 hours continuous use prior to need ing a charge Degradation 30 after 500 charge discharge cycles or two years whichever comes first Low battery LED Lights when approximately 1 hour of battery life remains Charge time Less than 4 hours with either sup plied charger Operating environment 32 F 0 C to 104 F 40 C at lt 75 RH non condensing Storage environment lt 80 RH meter and batt For 80 battery recovery 4 F 20 C
9. the other sensitivities levels Beware While in TURBO mode the SRL2 is extremely sensitive and will more easily trigger on abrupt or violent motions as well as very small changes in refrigerant levels Handle with care when in TURBO mode Leak Detection Procedure Keep the SRL2 away from any areas of potential refrigerant leakage until the warm up and calibration period is over The warm up and calibration sequence lasts about 30 seconds after ON OFF is pressed Allow the SRL2 to fully warm up before using to avoid false triggering On startup meter defaults to high sensitivity uick Tips e Keep the wand tip moving past suspected leak locations 2 Once a leak is detected sweep the wand back over to pinpoint 3 To pinpoint larger leaks adjust sensitivity Filter Assessment amp Replacement The filter blocks moisture and other contaminants from the sensor When it gets wet it constricts flow of air and it will have to be replaced Unscrew the sensor tip and replace the white filter so that the rounded end is closest to the tip of the wand Use only the Fieldpiece supplied filter You can order from a distributor extra bags of replacement parts model RFL2 are available from Fieldpiece Model RFL2 contains 10 filters and 5 O rings A WARNING A DO NOT use the SRL2 without the proper fil ter correctly installed The most likely points for refrigerant leaks are at the soldered joints in refrigerant lines and chan