Controller SP- 14
Contents
1. Controller SP 14 The key enter to the controller s menu approval of the settings The key of exit going to previous option and start stop of the oven s work 3 The key multipurpose by pressing the key not entering to the MENU will increase the set temperature In MENU key is used to navigate between successive options and change their parameters 4 The key multipurpose by pressing the key not entering to the MENU will reduce the set temperature It is also used to move between further options and change the parameters in the MENU LCD display Lights off blower and feeder supplier STOP Lights of switch of the hot water pump Lights of switch of the central heating pump 9 Lights of switch on the blower 10 Lights of switch on of the tray 11 Light indicator of the pump POP Main use The purpose of the device is the automatic control of fan central heating pump C O pump hot water hot tap water circulating pump mixing or under floor heating POP work of screw tray The controller requires changing settings due to the diversity of fuel type of boiler and energy classification of the controller KG Electronics Company is not responsible for incorrect parameters and settings of the controller N Re PI yen The control process is performed by measuring the temperature of the liquid in the boiler and keeping the selected parameters during normal operation of the boiler The controll
2. P O P priority while the priority function is on the pumps are working in priority the first P O P pump on condition that the temperature difference between the pumps will be higher than 10 degrees in case of non fulfillment of this condition the pumps work without priority SUMMER MODE In summer mode the pump of hot tap water C O works and P O P pump only starts when the oven s temperature exceeds 90 degrees HOT WATER PUMP C W U Hysteresis of hot water pump Pump works on the principle of temperature difference Tank s temperature Reheating of C W U during the reheating the controller automatically changes the temperature of the oven to heat the storage tank to the desired temperature then goes into normal operation according to user settings Again turning reheating occurs when the tray temperature falls below the temperature of the oven CLOCK AND TIME ZONES Daily time Night time Setting the clock hours Setting the clock minutes The user sets himself from what time must operate day and night temperature The temperature is set in menu settings of the boiler After a power failure set the clock again Factory Settings This function restores the factory settings starts up settings ALARMS AND SECURITY The controller has a security in the form of a fuse 6 3 A located at the controller s back The controller is equipped with an audible alarm crossing 90 degrees it signal s high temperature and thermal protection and so
3. ch on off the blower continuous mode this function is used to switch the blower in continuous operation for a period no longer than 30 minutes after this time the controller switches to automatic mode E Switch on off the under floor heating pump P O P continuous mode this function is used to attach the POP pump for continuous operation no time limit BOILER S FIRING UP a Firing up start stop this function is used to start the controller s operation in automatic mode b User s parameters Time of supplying function is used to set the time of fuel supply for tray in automatic mode Firing up Supply break function is used to set a time break in supply by the tray in automatic mode Blower s power function is used in order to change the fan speed 10 degrees of power regulation Boiler s work Supplying time this function is used to set the time of the fuel supply by the tray in automatic mode called WORK Break in supply this function is used to set the time break in supplying by tray in automatic mode called WORK Fan power this function is used to change the fan speed 10degrees of power regulation Boiler s maintain Time of supply this function is used in order to set the time of fuel supply by a tray in automatic mode called MAINTAIN Break in supply this function is used to set the time break in supplying by tray in automatic mode called MAINTAIN Fan power this function is used to chang
4. e the fan speed 10degrees of power regulation Blowing off time Break in blowing off BOILER S SETTINGS Daily boiler s temperature regulation from 30 to 90 degrees Night boiler s temperature regulation from 30 to 90 degrees Boiler s hysteresis this function is used to set the hysteresis It is a delay in switching of the fan by the number of degrees such as 2 degrees of the hysteresis set temperature of 50 degrees the pump will turn on when the temperature drops to 48 degrees Temperature of extinction this function is used to set the temperature of central heating below which the controller finishes the supplying and blowing off Restarting is only possible after you restart the controller in firing mode Start Time of oven s firing up Maximum temperature of the screw Blower s type PUMPS OF CENTRAL HEATING C O AND FLOOR HEATING PUMP P O P Temperature of switching the pump C O and P O P this function is used to set the temperature at which the pump C O and P O P have to switch The range of temperatures in order to switch on the pump C O are between 25 to 80 degrees Temperature of switching off the pump P O P this function is responsible for turning off the pump after reaching the temperature set by the user For example we set the temperature at 45 degrees when the temperature has reached the desired P O P temperature P O P pump automatically shuts off and works only C O pump Regulation between 25 70 degrees
5. er has three operating zones which depend on the temperature Firing up mode frequent use of fuel from the tank short breaks between doses of fuel the maximum power of the fan parameters values set in MENU gt boiler s firing up gt user s parametres gt time of supplying gt supplying break Boiler s operation mode moving to the operation mode is after reaching the set temperature minus 100 oC the reduced supply of fuel from the tank extended breaks between successive doses of fuel blower power around 60 parameters values set in MENU gt boiler s firing up gt user s parameters gt time of supplying gt supplying break blower s power Back up boiler s mode moving to back up mode after crossing the set temperature Extremely short fuel supply breaks between further supplying up to two hours the fan works only during the supplying the fuel from the boiler s tank Manual work A Switch on off of the oven s tray continuous mode this function is used to attach the screw feeder in continuous operation for a period no longer than 30 minutes after this time the controller will go into automatic mode B Switch on off of the the central heating pump C O continuous mode this function is used to pump activation in continuous mode no time limit C Switch on the hot water pump C W U continuous work this function is used to switch the hot water pump in continuous mode no time limit D Swit
6. ftware in case of boiler s overheating In the case of ignition of fuel in the screw tray the controller will activate a screw for 30 min in order to transfer fuel and to prevent a fire Emergency activation temperature of a tray is regulated menu boiler settings The message tray s overheating will be displayed in order to delete the message turn off and switch on the controller by using the power key COMMENTS Do not place the sensors in a liquid Network cables placed at a sufficient distance from hot parts of the oven Be sure to set the power blowers at each stage of smoking Lighting work sustain Before any work of connecting pumps tray blowers and others DISCONNECT the CONTROLLER from the power CENTRAL HEATING SYSTEM SHOULD BE DONE ACCORDING TO POLISH STANDARDS