Home

Safety Instructions

image

Contents

1. e and the serial number S No of the unit provide the serial number found on the type label placed on the right side of the system Be ready to explain the nature of your problem to the service technician If you have questions about Kontron Embedded Computers or our products and services you may reach us at the aforementioned numbers or at www kontron com or by writing to Kontron Embedded Computers GmbH Oskar von Miller Str 1 85386 Eching 15 Industrial LCD Monitor KFM15 e User s Manual Version 2 20 37 Technical Support Returning Defective Merchandise Before returning any merchandise please 1 Contact our Customer Service department to obtain an RMA Return Material Authorization number Fax 449 8165 77 412 e mail service kontron com Make sure that you receive an RMA number from Kontron Embedded Computers Service before returning any merchandise Clearly write or mark this number on the outside of the package you are returning Describe the device failure behavior When returning goods include the name and telephone number of a person whom we can contact for further explanations if necessary Where applicable always include all duty papers and invoice s associated with the item s in question When returning a unit e Ensure that the unit is properly packed in the original box e Include a copy of the RMA form 15 Industrial LCD Monitor KFM15 e User s Manual Version 2 20
2. User s Manual Version 2 20 Product Description Product Description The KFM15 e is an industrial LCD monitor designed for high performance industrial applications The solid type of enclosure offers to the monitor a mechanical stability KFM15 e is therefore proper for industrial use Excellent image representation simple menu driven handling and plug amp play ability round off the qualities of this monitor The built in display is a 15 TFT XGA display with 1024 x 768 resolution and 350 cd m luminance brightness The protection pane built in front of the display is made of special glass and protects the display from destruction of mechanical manner for example get dirty scratches at the display surface The representation quality of the display is optimised also by the antireflection property of the protection pane Optionally the monitor can be equipped with a touch screen The KFM15_e comes with VGA analog DVI digital S Video analog Composite video analog signal inputs and provides compatibility with the existing and the future computer generation The KFM15 e can be equipped with an AC or a DC power supply unit The supply voltage range is indicated at the type label The type label and the approval marks are placed on the back of the unit Fig 1 Industrial LCD monitor KFM15 e shown as 19 rackmount version DS Please take care when installing and powering on the monitor that the air openings
3. to choose the sub menu values To save a new setting press the button Menu of the KFM15 e Press the button Select to leave the sub menu 10 Press the button Select to leave the main menu The OSD menu and the possible settings are described in the provided KFM OSD Menu Description documentation 15 Industrial LCD Monitor KFM15 e User s Manual Version 2 20 Installation Instructions Installation Instructions ER Please observe the described hints in the chapter Safety Instructions and the specification listed in the chapter Main Specifications Instruction for Mounting Ss Please take into account the needed free space on the interface side before you install the monitor into an industrial cabinet an instrument panel or other cabinets You find the description of the interfaces being available in the section Interfaces Important Instructions KFM15 e has to be installed only by trained and qualified personal Make sure there is sufficient air circulation around the device when installing the KFM15 e The openings for cooling on upper and bottom side of the device must not be obstructed When installing KFM15 e into an industrial cabinet leave at least 5 cm approx 2 of free space around the unit to prevent the device from possibly overheating The 19 industrial cabinet must stand firmly in place If further stabilisation is necessary then bolt the ind
4. EMC laws apply If the user modifies and or adds to the equipment e g installation of add on cards the prerequisites for the CE conformity declaration safety requirements may no longer apply 8 15 Industrial LCD Monitor KFM15 e User s Manual Version 2 20 Scope of Delivery Scope of Delivery L D O O O D wo Industrial LCD monitor KFM15 e A or B This user manual for the industrial LCD monitor KFM15 e KFM OSD Menu Description AC power cord for AC version only VGA cable connector 2 m 8x M4 nut DC Phoenix connector power plug terminal for DC version only Optional Parts LI USB or serial COM touch screen cable connector depending on the ordered touch screen terminal configuration optional Available lengths for USB cable connector Type A male Type A male 2m 5m COM RS232 cable connector 2 m 5 m 10m VGA cable connector Available lengths 2 m 5 m 10 m DVI cable connector Available lengths 2 m 5 m CD ROM with the installation software and the driver for touch screen if the KFM15 e is ordered with the optional touch screen Type Labels and Product Identification The type label of your monitor KFM15 e is attached at the back of the device Type label Product identification KFM15 e A Industrial LCD Monitor KFM15 e with AC power supply unit KFM15 e B Industrial LCD Monitor KFM15 e with DC power supply unit 15 Industrial LCD Monitor KFM15 e
5. at the bottom and upper side of the device behind the front panel must be not obstructed by objects 10 15 Industrial LCD Monitor KFM15 e User s Manual Version 2 20 Product Description Front Panel The front plate of the KFM15 e is available alternatively as 19 front plate or in panel mount version The 19 front plate version is suitable for the installation of the monitor in 19 industrial cabinets Therefore four mounting holes are available The panel mount version is suitable for the installation of the monitor in an instrument panel or other cabinets Therefore at the rear side of the front plate are available eight threaded studs At the front side are the control elements of the on screen displays OSD the On Off button with the Status LED that indicate the status of the monitor the 19 front plate and the 15 display with the protection pane or touch screen optional The protection class IP 65 is ensured at the front side of the monitor Fig 2 KFM15 e front side shown as19 front plate version 1 Front panel shown as 19 3 Controls and LED indicator rackmount frontpanel9 4 Mounting holes 2 15 display with protection plate or touch screen optional 15 Industrial LCD Monitor KFM15 e User s Manual Version 2 20 11 Product Description Display The built in display is a 15 TFT XGA display with a resolution of 1024 x 768 and 350 cd m of luminance brightness In fron
6. gt Benutzerhandbuch User s Manual 15 Industrial LCD Monitor KFM15 e User s Manual Version 2 20 Kontron Embedded Computers GmbH 0 0096 2746 C kontron If it s Embedded it s Kontron Contents Contents INTODUCT ON m pasucevcesdcerantevesassoneteclensoedunusiesnacterssendetebaedseldansded chundset eetedistonees 3 Symbols used in this Manual nennen 4 Important Instructions seaue esee essei eese eee nene einn nana anna annus aaa nasa aaa n uasa aaa na 5 Note on the Warrannty ccccescseeeeseeceseseneeeenseneeeseenseseseeeeeessecensseneeeseseeeeseeeesenees 5 Exclusion of Accident Liability Obligation eese 5 Liability Limitation Exemption from the Warranty Obligation 5 EIC EP 6 EGG Statements i tec eee abe a ex bcn eerste 8 Electromagnetic Compatibility 8 Sope of DeliV t 9 Optional Parts oculta teal ee e eee 9 Type Labels and Product Identification 9 Product Description eee e esee esee eiae sese enne niin anna nina haha anna asas rasan anna 10 elle TE EE 11 Display 5c ERE PEERS 12 Display with Touch Gcreen A 12 Controls and LED Indicator eseeeeeeneenennennenn 13 ett aide iium NE e neu 15 une 15 Power Plug cessed emet tne oe Ep eee ieee vie 17 NEID eege L 18 Power Supply EE 1
7. or optional right side rear mounted 1x On Off button for image representation adjustment on screen 1x Menu button of OSD 1x Up button of OSD 1x Down button of OSD 1x Select button of OSD LED indicator At the Front side 1x Status LED Plug amp Play VESA DDC1 2B EDID Ver 1 3 EE AC or DC Power AC or DC Power plug At the left side rear mounted Backlight lifetime 50 000 h Protection class IP65 frontal 15 Industrial LCD Monitor KFM15 e User s Manual Version 2 20 29 Main Specifications Mechanical Specifications Front plate HxWxD HxWxD 333 5 x 450 x 3 mm 7U x 19 x 3 mm 13 13 x 17 72 x 0 118 Material steel zinc plated steel zinc plated gus black powder coated Frontal black powder coated C 276 5 mm 10 886 276 5 mm 10 886 Width 393 mm 15 472 393 mm 15 472 m 60 mm 2 362 60 mm 2 362 Material steel zinc plated steel zinc plated Weight approx 6 5kg 14 330 Ibs approx 6 5 kg 14 330 Ibs without packing without packing Electrical Specifications System Integrated Input Version PSU KFM15 e A AC Power Supply 100 240 VAC 50 60 Hz max 0 3 A KFM15_e B DC Power Supply 18 36 VDC max 1 5 A 30 15 Industrial LCD Monitor KFM15_e User s Manual Version 2 20 Main Specifications Environmental Specifications Operating temperature 0 50 C 32 122 F Storage transit 20 60 C temperature 4 140 F Relative hu
8. 8 Power Cord Connection xa 3ccac ite be ge eh eit ees ice teet ati eee 19 AC Connection a iin hints E i i te ee ee ed 19 IBeXerevuir Tei 20 On Screen Display OSD nene ume gH RB EU 22 Operation of the OSD Men 22 Installation Instructions 1 essei esee eese einen enin nnne anna nhan nna a anna ananas 23 Instruction for Mounting AN 23 Panel Mount Version ee uitio tee cepe tiec ie ke oe ERRARE EER AKA Dre n 24 Rack Mount Version 2i ss ccscsseccepasaesedzesaazeapinseesascaiaatuacoantsiaesnastacisaescacessaslepananaciadsy 24 15 Industrial LCD Monitor KFM15 e User s Manual Version 2 20 1 Contents Monitor Connecting and Turning On eeeeses esee esee nenne nnn innata nana 25 Installation of the Touch Screen Goftware 26 Calibrating the Touch Green 27 Maintenance and Prevention eerie esee ease rennen eina in nhat nana anu 28 E RE iere tpr ara aano peri cade peu rt aeui rte n erasa pague 29 Mechanical Specifications ccceecceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeseeseeeeeeeeeeneeeneeeeeaes 30 Electrical SpacifiCatioris s cnt ond cette tte ctt e 30 Environmental Specifications A 31 CE Directives and Standards AAA 32 Technical Appendix Interfaces eeeeee eese eiie e enne nena tn nana 33 VGA GOonhector oett ete n bug Oe ebd a 33 DVI D Connector Single Link 34 S Video Connector i ooo een Roe T 35 C Video Composite Connect
9. KFM15 e supports at this interface data transfer with a resolution up to 1024 x 768 XGA S Video Input The S Video input is a 4 pin mini DIN connector female and allows you to connect external analog signal sources as e g DVD or video player The industrial LCD monitor KFM15 e supports at this interface TV pictures format PAL 768 x 576 NTSC 640 x 480 and SECAM Composite Video Input The Composite Video input is a cinch connector yellow female and allows you to connect external analog signal sources as e g DVD or video player The industrial LCD monitor KFM15 e supports at this interface TV pictures format PAL 768 x 576 NTSC 640 x 480 and SECAM 16 15 Industrial LCD Monitor KFM15 e User s Manual Version 2 20 Product Description USB COM Touch Screen Terminal e This interface is available as an USB or serial COM interface only if the industrial LCD monitor KFM15 e is equipped with touch screen Depending on the ordered configuration of the touch screen connector this interface is provided as T USB interface version 1 1 type A female or as Q Serial COM interface 9 pin D SUB socket RS232 configured Power Plug The power plug is an AC inlet connector or a DC Phoenix connector depending on the ordered version and allows the connection to the corresponding power source through the power cord supplied 15 Industrial LCD Monitor KFM15 e User s Manual Version 2 20 17
10. Make sure that you have the right polarity of the connection see Fig 7a 6 Fasten the screws to secure the negative and positive voltage wire into the clamps of the plug terminal US The second end of each wire will be prepared as required for the connection to the DC power supply Connect the KFM15 e to the DC power source as follows 7 Plug the one end of the DC cable connection Phoenix plug terminal to the Phoenix plug of the KFM15 e 8 Connect the other end of the DC cable connector to a corresponding DC power source 15 Industrial LCD Monitor KFM15 e User s Manual Version 2 20 21 Product Description On Screen Display OSD Over the On Screen Display OSD can be installed the features as OSD position and time brightness contrast color sharpness and others Some of these menus have sub menus The push buttons allow to select to scroll to install in the OSD main menu or OSD submenu Operation of the OSD Menu 1 oe A 9 8 9 Press Menu to display the main menu The buttons Up and Down allows moving between the functions of the main menu by use of Press the button Menu to choose a main menu function The buttons Up and Down allow moving between the sub function Press the button Menu to choose a sub menu function The button Up to increase and the button Down to decrease allows the adjustment of the sub menu values Press the button Menu
11. Product Description Air Openings Behind the front plate at the housings upper and bottom side are the air openings Fig 5 upper air openings Fig 5a bottom air openings DS Please take care when installing and powering on the monitor that the air openings at the bottom and upper side of the device behind the front panel must be not obstructed by objects Power Supply The KFM15 e can be equipped with an AC PSU or a DC PSU The supply range can be read off the type label attached on the back of the unit System Integrated Input Version PSU KFM15 e A AC Power Supply 100 240 VAC 50 60 Hz max 0 3 A KFM15 e B DC Power Supply 18 36 VDC max 1 5 A The suffix A on the type label System Version KFM15 e A of the system stands for the marking of the Kontron devices which are equipped with an AC power supply unit The suffix B on the type label System Version KFM15 e B of the system stands for the marking of the Kontron devices which are equipped with a DC power supply unit 18 15 Industrial LCD Monitor KFM15 e User s Manual Version 2 20 Product Description Power Cord Connection US Please observe the hints described in the chapter Safety Instructions The voltage of the power source must agree with the voltage value on the type label AC Connection Abb 6 AC power plug 1 Connect the supplied AC power cord into the system AC power plug 2 Connect
12. be carried out by qualified personnel authorized by Kontron Embedded Computers familiar with the associated dangers 4 Itis not allowed to open the device Q Only original accessories approved by Kontron Embedded Computers may be used 1 It must be assumed that safe operation is no longer possible if the device has visible damage or if the device no longer functions In these cases the device must be shut down and secured against unintentional operation 15 Industrial LCD Monitor KFM15 e User s Manual Version 2 20 7 Safety Instructions FCC Statement This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Electromagnetic Compatibility This product has been designed for industrial commercial and office use including small business use The most recent version of the EMC guidelines EMC Rules 2004 108 EC and or the German
13. daily use N esi 4 15 Industrial LCD Monitor KFM15 e User s Manual Version 2 20 Important Instructions Important Instructions This chapter contains instructions which must be observed when using your industrial LCD monitor KFM15 e The manufacturer s instructions provide useful information on your industrial LCD monitor KFM15 e Note on the Warranty Due to their limited service life parts which by their nature are subject to a particularly high degree of wear wearing parts are excluded from the warranty beyond that provided by law This applies to the display backlighting for example Exclusion of Accident Liability Obligation Kontron Embedded Computers shall be exempted from the statutory accident liability obligation if the user fails to observe the safety instructions Liability Limitation Exemption from the Warranty Obligation In the event of damage to the device caused by failure to observe the hints in this manual and on the device especially the safety instructions Kontron Embedded Computers shall not be required to honor the warranty even during the warranty period and shall be exempted from the statutory accident liability obligation 15 Industrial LCD Monitor KFM15 e User s Manual Version 2 20 5 Safety Instructions A Safety Instructions Please read this section carefully and observe the instructions for your own safety and correct use of the device This chapter also contains informa
14. le Link Signal Name Description DVI D Connector female Ines reena THOS Date 2 e oo wos sit 0 45 NC Reserved for future use Jose noct aaa cook 7 psa pc EDD ae 8 N Reserved for future use B mes sem sme messi eee 0 NE e qw p e s e p qw 34 15 Industrial LCD Monitor KFM15 e User s Manual Version 2 20 TITEL mmo j j 6 6 61 Te eL I JE IE JEJE II Technical Appendix Interfaces S Video Connector Signal Name Description 4 pin MiniDIN Connector female C Video Composite Connector Signal Name Description Cinch Connector yellow female 2 CVBS Composite video signal USB Touch Screen Connector Pin Signal Name 4 pin USB Socket Type A Version 1 1 15 Industrial LCD Monitor KFM15 e User s Manual Version 2 20 35 Technical Appendix Interfaces Serial Touch Screen Connector RS232 Data Carrier Detect Receive Data Transmit Data Data Terminal Ready Signal Ground Data Set Ready Request to Send Clear to Send Ring Indicator 36 15 Industrial LCD Monitor KFM15 e User s Manual Version 2 20 Technical Support Technical Support For technical support please contact our Technical Support department Tel 49 0 9461 950 104 Fax 49 0 9461 950 200 e mail support kontron com Make sure you have the following information on hand when you call e the unit part id number P No
15. manual is protected by copyright All rights are reserved by Kontron Embedded Computers Copies of all or part of this manual or translations into a different language may only be made with the prior written consent of Kontron Embedded Computers Kontron Embedded Computers points out that the information contained in this manual is continuously being updated in line with the technical alterations and improvements made by Kontron Embedded Computers to the products and thus this manual only reflects the technical status of the products by Kontron Embedded Computers at the time of printing 2007 by Kontron Embedded Computers Printing and duplication even of sections is only permissible with the express approval of Kontron Embedded Computers GmbH Oskar von Miller Str 1 85386 Eching near Munich Germany 15 Industrial LCD Monitor KFM15 e User s Manual Version 2 20 3 Introduction Symbols used in this Manual Symbol Meaning This symbol indicates the danger of injury to the user or the risk of damage to the product if the corresponding warning notices are i B not observed This symbol indicates that the product or parts thereof may be damaged if the corresponding warning notices are not observed This symbol indicates general information about the product and the user manual This symbol indicates detail information about the specific product configuration S amp This symbol precedes helpful hints and tips for
16. midity 20 80 non condensing operating Humidity storage 5 95 non condensing Operating altitude 10 000 ft 8 048 m Storage transit altitude 40 000 ft 12 191 m Operating shock 5 G 11 ms duration half sine Storage transit shock 30 G 11 ms duration half sine Operating vibration 10 58 Hz 0 075 mm 58 500 Hz 0 5 G Storage transit vibration 10 58 Hz 0 15 mm 58 500 Hz 1 0 G 15 Industrial LCD Monitor KFM15 e User s Manual Version 2 20 31 Main Specifications CE Directives and Standards Low Voltage Directive 2006 95 EC Electrical Safety EMC Directive 2004 108 EC EC Marking 93 68 EEC EUROPE EN 60950 1 2006 to meet UL 809501 200 Fist Eaton Generic emission standard for industrial environments Emission EN 61000 6 4 2001 EUROPE Generic standards Immunity for industrial environments Immunity EN 61000 6 2 2005 32 15 Industrial LCD Monitor KFM15 e User s Manual Version 2 20 Technical Appendix Interfaces Technical Appendix Interfaces The following tables show the plug assignments for the external connections of the KFM15 e Low active signals are indicated by a minus sign VGA Connector Pn Signal Name red green blue 4 is NC GND Fused VCC GND NC DDC Data HSYNC VSYNC DDC Clock 15 Industrial LCD Monitor KFM15_e User s Manual Version 2 20 33 Technical Appendix Interfaces DVI D Connector Sing
17. n control panel program and then select Calibration Follow the directions displayd on the screen Fore more information on calibration refer to the user documentation enclosed on the supplied CD with the touch screen drivers e Whenever you change the resolution you have to calibrate the e touch screen 15 Industrial LCD Monitor KFM15 e User s Manual Version 2 20 27 Maintenance and Prevention Maintenance and Prevention Kontron Embedded Computers devices require minimal maintenance and care to keep them operating correctly 1 Occasionally wipe the system with a soft dry cloth 1 Remove persistent dirt by use of a soft slightly damp cloth only use a mild detergent DS Use no abrasives abrasion sponges steel wool metal threads or solvent like alcohol acetone washing gasoline to clean the displays protection pane or the surface of the touch screen 28 15 Industrial LCD Monitor KFM15 e User s Manual Version 2 20 Main Specifications Main Specifications TFT LCD Display Diagonally Size 15 active area 304 1 x 228 1 mm Resolution Pixel Pitch Viewing angle r 1 u d Contrast ratio Touch screen Type 4 wire resistive optional Terminal connection optional as COM RS232 or USB 1 1 connector Interfaces At the left side rear mounted 1x VGA analog input 1x DVI D digital input 1x S Video analog input 1x Composite Video analog input Operating elements At the front side
18. ndustrial LCD Monitor KFM15 e User s Manual Version 2 20 25 Monitor Connecting and Turning On Installation of the Touch Screen Software The drivers are on the included CD ROM for the following operating systems T DOS Windows 9x Me Windows 2000 XP Windows CE L D vu O Linux After installing the touch screen driver be sure to restart your computer to load and activate the touch screen driver Sr S Afterwards you calibrate the touch screen 26 15 Industrial LCD Monitor KFM15 e User s Manual Version 2 20 Monitor Connecting and Turning On Calibrating the Touch Screen After the installing and connecting your KFM15_e monitor and installing the touch screen you have to calibrate the touch screen Calibration serves two purposes T Sets the active area of the touch screen J Aligns the active area of the touch screen to the screen s image r Before you calibrate the touch screen let the monitor warm up for 30 minutes and then center the screen s image within the Screen area Calibration aligns the active touch sensitive area of the touch screen with the image on the display Calibration also determines the edges of the screen s image and locates the center of the touch screen If the touch screen is not calibrated properly the active area of the touch screen may not be aligned with the screen s image or may be unnecessarily small in size To calibrate the touch screen open the touch scree
19. or nennen 35 USB Touch Screen Connector sese 35 Serial Touch Screen Connector R8232 sse 36 Technical SUPP OFT EM 37 Returning Defective Merchandise s e 38 2 15 Industrial LCD Monitor KFM15 e User s Manual Version 2 20 Introduction Introduction Kontron Embedded Computers would like to point out that the information contained in this manual may be subject to technical alteration particularly as a result of the continuos upgrading of Kontron Embedded Computers products The attached documentation does not entail any guarantee on the part of Kontron Embedded Computers with respect to technical processes described in the manual or any product characteristics set out in the manual Kontron Embedded Computers does not accept any liability for any printing errors or other inaccuracies in the manual unless it can be proven that Kontron Embedded Computers is aware of such errors or inaccuracies or that Kontron Embedded Computers is unaware of these as a result of gross negligence and Kontron Embedded Computers has failed to eliminate these errors or inaccuracies for this reason Kontron Embedded Computers expressly informs the user that this manual only contains a general description of technical processes and instructions which may not be applicable in every individual case In cases of doubt please contact Kontron Embedded Computers This
20. ounted 1 Menu button Up button Down button Select button LED indicator o a A CO I On Off button Fig 3 Controls and LED indicator On Off Button and LED Indicator On Off Button Press this button in order to switch on or off the monitor KFM15 e Even if you switch the monitor off with the On Off button a standby voltage is further present in the device The unit is complete disconnected from the power source only when the power cord is disconnected from the power source Therefore the power cord and its connectors must always remain easily accessible 15 Industrial LCD Monitor KFM15 e User s Manual Version 2 20 18 Product Description Status LED green Status LED orange This LED lights up green if the monitor is switched on and the data source is available Prerequisite The power cord must be connected to a corresponding power source This LED lights up orange if the monitor is switched off or no data source is available Prerequisite The power cord must be connected to a corresponding power source If this LED does not light up after turning on the device then you have to check the mains power source On Screen Display Buttons The push buttons of the On Screen Display allow you to select to scroll to install in the OSD main menu or OSD submenu see chapter On Screen Display OSD 15 Industrial LCD Monitor KFM15 e User s Manual Version 2 20 Product Descri
21. ption Left Side The interfaces and the power plug AC or DC are on the left side of the monitor DVI D digital interface VGA analog interface Composite Video interface S Video interface Optional touch screen terminal USB or COM2 shown without interface AC or DC power plug depending on the ordered version shown with AC power plug Fig 4 KFM15 e left side Interfaces The following interfaces with standard pin assignments are available d C O ve VGA analog input DVI D digital input S Video analog input C Video Composite Video analog input USB COM interface as the touch screen terminal interface at the same time By means of the OSD menu function Select you can select which of the signal source shall be represented on the display You can connect one corresponding signal source to each video 15 Industrial LCD Monitor KFM15_e User s Manual Version 2 20 15 Product Description VGA Input The VGA input is a 15 pin D SUB connector female and allows you to connect an analog graphic card by use of the supplied VGA cable connector The industrial LCD monitor KFM15_e supports at this interface data transfer with a resolution up to 1024 x 768 XGA 85 Hz and Sync On Green SOG DVI D Input This Input is configured as a DVI D digital female interface This interface support digital data transfer The industrial LCD monitor
22. t of the display is installed a glass protection pane with antireflection properties This protects the display surface from dirt and scratches also The technical specifications of the built in display are listed in the chapter Main Specifications Display with Touch Screen The KFM15_e can be equipped optionally with a resistive touch screen The installed touch screen is a 4 wire resistive touch screen The terminal configuration of the touch screen can be alternatively an USB or a COM interface The touch screen is connected by means of provided cables via the COM RS232 or USB interface to an external PC with corresponding interface The display surface of the KFM15 e is also mechanically protected through the touch screen The touch screen registers contact of a finger or a pen and moves the mouse pointer These functions under integration of the necessary software only see chapter Installation of the Touch Screen Software You get the corresponding touch screen driver for your operating system on a storage media CD ROM supplied 12 15 Industrial LCD Monitor KFM15 e User s Manual Version 2 20 Product Description Controls and LED Indicator At the right side of the front plate are situated the control buttons of the On Screen Display OSD the On Off button and the Status LED ze The keys of the OSD menu and the power On Off button can be optionally mounted to the right side of the monitor rear m
23. the other end of the AC power cord into a corresponding outlet Use the power cord suitable for the power supply in your country Do not remove or alter the grounding prong on the power cord In situations where a two slot receptacle is present have it replaced with a properly grounded three prong grounding type receptacle 15 Industrial LCD Monitor KFM15 e User s Manual Version 2 20 19 Product Description DC Connection D The length of the DC connecting wires may not exceed 10 m i DC Phoenix i connector i DC Phoenix connector with plug terminal Fig 7 DC Phoenix connector Fig 7a DC Phoenix connector with plug terminal supplied For the DC connection prepare the connecting wires using the supplied Phoenix plug terminal 1 Cut the required length of two isolated wires up to 1 5 mm 2 Strip each end 5 7 mm 3 Twist the striped wire ends and tin it with solder 4 Loosen the two slotted pan head screws of the DC plug terminal far enough so that you can insert the end of the power cord Fig 8 Phoenix plug terminal with positive and negative voltage wire example 1 Phoenix plug terminal 3 Negative voltage wire black 2 Slotted pan head screws 4 Positive voltage wire red 20 15 Industrial LCD Monitor KFM15 e User s Manual Version 2 20 Product Description 5 Insert the negative and positive voltage wire into the corresponding clamp of the Phoenix plug terminal
24. tion on approval and interference suppression of your KFM15 e The device has been built and tested by Kontron Embedded Computers in accordance with EN 60950 VDE 0805 and left the company in a perfectly safe condition In order to maintain this condition and ensure safe operation the user must observe the instructions and warnings contained in this manual LI The device must be used in accordance with the instructions for use LI The electrical installations in the room must correspond to the requirements of the respective regulations 1 Take care that there are no cables particularly power cables in areas where persons can trip over them 1 Do not use a power cable in sockets shared by a number of other power consumers Do not use an extension cable 1 Only use the power cord supplied Q The unit is only completely disconnected from the main power source when the power cord is disconnected either from the power source or from the unit Therefore the power cord and its connectors must always remain easily accessible m Only devices and components which fulfill the requirements of a SELV circuit Safety Extra Low Voltage in accordance with EN 60950 may be connected to the interfaces of the system QO All plugs on the connection cables must be screwed or locked to the housing 6 15 Industrial LCD Monitor KFM15 e User s Manual Version 2 20 Safety Instructions LI Maintenance or repair on the open device may only
25. ustrial LCD monitor KFM15_e can be connected to IBM PC systems equipped with corresponding graphics capability 1 Connect the PC system s video signal output interface to the video signal input of the KFM15 e by use of the supplied video signal cable depending on your ordering 2 If your KFM15 e is equipped with touch screen COM or USB terminal you have to connect the touch screen terminal to the corresponding interface of the PC system by use of the supplied touch screen cable connector 3 Connect the power cord as described in the chapter Power Cord Connection 4 Push the Power On Off button to turn on the monitor The PC needs to be set to an appropriate graphics mode that has the same resolution with the LCD panel to have clear screen image The colour representation of the image on each monitor can differ by physically causes and is dependent on the video signal Source If you prefer another colour temperature or want to adapt the colour representation of images on two monitors you have to install these features in the OSD menu under Color Execute these settings only after reaching of the full operating temperature of the monitor approx 30 minutes When the screen is not in use it must be turned off or the pattern must be frequently changed by a screen saver If it displays the same pattern for a long period of time brightness down or image sticking may develop due to the structure of LC Displays 15 I
26. ustrial cabinet to the floor or anchor it on the wall The voltage feeds must not be overloaded Adjust the cabling and the external overcharge protection to correspond with the electrical values indicated on the type label The type label is located on the left side of the monitor 15 Industrial LCD Monitor KFM15 e User s Manual Version 2 20 23 Installation Instructions Panel Mount Version If you install the panel version of the KFM15 e into an instrument panel or other cabinet use the eight threaded studs M4 on the rear side of the front plate For the panel assembly cut a window and eight pre drill holes according figure 6 The system must be attached firmly with eight M4 metric nuts Before mounting remove the protective film on the rubber seal at the rear side of the display front plate The contact surface with the rubber seal must be clean and flush 8 75 S T 158 75 l e 300 158 75 217 217 Fig 6 Hole pattern for the KFM15 e Panel mounting all values in mm Rack Mount Version If you install the rack mount version of the KFM15 e into a 19 industrial cabinet at the front plate four mounting holes are at your disposal The system has a height of 7U and will be secured with four screws in the 19 industrial cabinet 24 15 Industrial LCD Monitor KFM15 e User s Manual Version 2 20 Monitor Connecting and Turning On Monitor Connecting and Turning On The ind

Download Pdf Manuals

image

Related Search

Related Contents

John Lewis JLTDC 05 Clothes Dryer User Manual  Gebruiks- aanwijzing Koelkast User manual Fridge Notice d  Orion STARSHOOT 52187 User's Manual  User Manual  CPI—1E Operating Instructions  F Manuel d`utilisation  Semiconductor Product Design & Innovations - Digi-Key  P521 External Control Codes  LeapFrog Leapster 2 708431307070 User's Manual  マシニングセンタCAD/CAM学習システム  