Home

MUSC Pediatrcic ED Telemedicine Laptop User`s

image

Contents

1. SIP Domain musc edu These addresses should already be entered If not connected to an Ethernet wall jack via an Ethernet cord you will need to be connected to a WiFi network Once logged in the settings icon is located in the upper right hand corner of the Jabber window Click on that then click settings From there you can modify the sign in settings as above and check or modify the audio or video settings In the Audio section you can choose the microphone and speakers that you want to use from the dropdown boxes either headphones or computer microphone speakers and test to make sure they re functioning Both the microphone and speakers should be set to Logitech USB Headset The microphone slider allows you to speak into the microphone and visually see that the output is in the recommended range The Test button next to the speaker selection will play chimes through the headset or speakers depending on which is selected CONTACT INFORMATION OneVision Technical Support 877 866 9800 e Available 24 7 for equipment support i e Cisco cart camera TotalExam camera and stethoscope e support onevisionsolutions com e Please have cart serial number available when calling o Press Home button on remote gt Settings gt System Information gt Module serial number MUSC IT Support e Call for problems related to network and calling e Michael Haschker 843 792 8314 e Lori Upshur 843
2. 864 9951 daytime only e OCIO IS NST musc edu If these resources cannot address the problem call Dr David McSwain 919 672 8866 or email mcswains musc edu
3. MEDICAL UNIVERSITY OF SOUTH CAROLINA Pediatric Emergency and Critical Care Telemedicine MUSC Pediatrcic ED Telemedicine Laptop User s Guide Medical University of South Carolina ivision of Pediatric Critical Care 135 Rutledge Ave Charleston SC 29425 Phone 843 792 2618 Fax 843 792 3022 TABLE OF CONTENTS Logging in to the Laptop cccccccccecscceces CISCO Jabber VIACO scesscesscssccescesscoscees Using the Headset ccccscecccceccscsccccececes LOCKING Drawer ceccececcsceccececcececcececceces Using the StethOsScope cccccceccsceccccsceces Between USC viscsiisrcsnsteinescssesoverscasosecosnesonees TROUBLESHOOTING sccssccssscesscossconsees Contact Information cccccccccececcsceccececes LOGGING IN TO THE LAPTOP Turn laptop on Connect the headset microphone to the USB port on the laptop if not already connected If you wish to use the wireless mouse instead of the touchpad turn it on with the switch located on the bottom of the mouse Select pedsed User ID on the Windows login page Connect to a WiFi connection by clicking the network connection icon in the lower right corner of the screen Then select the appropriate muscsecure and login using your NetID and password Not connected mil Connections are availahie Wireless Network Connection muscsecure muscquest Name muscsecure Signal Strength Good HP5O167E Security Type WPA2 Radio Type 802 11lagq
4. Other Network SSID muscsecure Open Network and Sharing Center 11 44 AM 3 20 2013 3 CISCO JABBER VIDEO Click the Cisco Jabber icon pinned to the taskbar at the bottom of the screen or double click the Cisco Jabber icon on your desktop screen Jabber should be set to automatically log you in If not the username and login is pedsed Cisco Jabber Video for TelePresence Username Password Remember me There are multiple ways to place a call a Enter a name number or IP address in the field labeled Type name number or address then press Start on the appropriate number in the list below b Select the appropriate name number from the Favorites list and press Start c Select the appropriate name number from the History and press Start Jabber Video mf David McSwain Type name number or address History Charleston Co School Offline ccsd4 musc edu David Habib Offline habibd musc edu GlobalMed demo cart 8438 761413 musc edu Haschker Michael Offline haschker musc edu Melissa Evans Offline mceS musc edu MobilePeds2 8437921002 musc edu MobilePeds3 8437921003 musc edu MUSC Cisco cart 001 musc edu nerrTty 13 favorites Add favorite k tes Once the call is connected the control bar appears at the bottom of the Jabber window when you move your mouse over the window The icons on the
5. control bar in order from left to right are Display self view Freeze unfreeze near end video Mute unmute near end microphone Volume control mute Share laptop screen and programs e End call To control the far end camera click the icon shown below in the upper right corner That will bring up the joystick control above the control bar which allows you to zoom in and out and control the direction of the remote camera To share your computer screen or a specific program running on your computer example a web page on Internet Explorer click on the share screen icon on the control bar second from the right then select what you want to share from the menu presented USING THE HEADSET In order to ensure confidentiality of telecommunications conducted via your laptop the included headset should be used any time your communication may be overheard The headset also allows for clearer communication if there is ambient noise Position your microphone near the tip of your chin to avoid breathing noise being transmitted too loudly You can check audio settings in the settings window see below to confirm that Jabber is using the headset for audio functions LOCKING DRAWER The stethoscope and printed user s manual are located in the locking drawer underneath the keyboard To access the drawer enter C then 1234 then hit the key button USING THE STETHOSCOPE The Littmann BlueTooth S
6. ope from the drop down box PECCT11 My Stethoscope PECCT2 Da Click the stethoscope icon to the left of the drop down box to pair the stethoscope with the computer On the Littmann stethoscope press the M button to bring up the menu then press M again to connect the stethoscope The remote site participant will Host a Session which will create a Session ID Select Join a Session and enter the Session ID they provide in the pop up box Once you have joined the session you can place the ear buds of the stethoscope in your ears and hear whatever is auscultated by the stethoscope at the remote site BETWEEN USE You may leave the laptop plugged in and powered on between uses although it should be intermittently restarted to check for automatic updates to software You can also check for updates by typing Windows Update in the Search field on the Start menu and opening the Windows Update program Store the stethoscope in the locking drawer between uses TROUBLESHOOTING See the Jabber User Guide on the desktop screen for more detailed instructions on the use of the Jabber software and troubleshooting SETTINGS The sign in settings in Jabber can be accessed from the sign in window by clicking the tools icon just beneath the password box That will list the server addresses used to sign in which should be as below Internal Server gatekeeper musc edu External Server bc musc edu
7. tethoscope operates utilizing the Littmann Stethoscope software on the attached laptop Littmann stethoscope Double click the Littmann Stethoscope icon on the desktop to open the Littmann TeleSteth software The login username is pecct11 The password is PECCT11tele case sensitive ttmann TeleSteth Online Auscultation System lt 7 E a Share auscultatory recordings amp analysis results with colleagues across town or across the globe Use the Internet to stream auscultations in real time to colleagues located anywhere in the world Share recorded auscultations via store and forward with a client server system Easily accessible from your PC Fully compatible with Littmann StethAssist Heart and Lung Sound Visualization Software Username pecct1 Password Z Remember my username Forgot Password To establish an account contact 1 800 228 3957 Learn more about stethoscopes and software products at www littmann com 3M 2012 All Rights Reserved Use of this software application is subject to the terms of a license agreement Unauthorized use is strictly prohibited Login Username PECCT Password PECCT tele Press the power button on the Littmann BlueTooth Stethoscope to turn it on Ensure the BlueTooth dongle is plugged in to a USB port on the laptop Aa La dii In the TeleSteth window select the name of the stethosc

Download Pdf Manuals

image

Related Search

Related Contents

  プリント基板向け砥石のカタログはこちら  Istruzioni d`impiego  Istruzioni per l`uso - Instructions Manuals  Samsung PS-42D51S manual de utilizador    

Copyright © All rights reserved.
Failed to retrieve file