Home

User Manual

image

Contents

1. a power cord that didn t ship with the equipment ensure that it is rated for the voltage and current labeled on the equipment s electrical ratings label The voltage rating on the cord should be higher than the one listed on the equipment s ratings label m Observe all precautions and warnings attached to the equipment M If you dont intend on using the equipment for a long time disconnect it from the power outlet to prevent being dam aged by transient over voltage H Keep all liquids away from the equipment to minimize the risk of accidental spillage Liquid spilled on to the power supply or on other hardware may cause damage fire or electrical shock m Only qualified service personnel should open the chassis Opening it yourself could damage the equipment and invali date its warranty m If any part of the equipment becomes damaged or stops functioning have it checked by qualified service personnel What the warranty does not cover m Any product on which the serial number has been defaced modified or removed m Damage deterioration or malfunction resulting from L Accident misuse neglect fire water lightning or other acts of nature unauthorized product modification or failure to follow instructions supplied with the product L Repair or attempted repair by anyone not authorized by us L Any damage of the product due to shipment O Removal or installation of the product L Causes external to the product such as electric po
2. FF Button www rackmountmart com Dimensions RA401 7 9 RA401 7 6 195 195 Y 8 Y 8 www rackmountmart com P 5 Specifications Operating 0 to 50 C Degree Storage 5 to 60 C Degree Relative humidity 5 90 non condensing Shock 50G peak acceleration 11ms half sine wave Vibration 58 100Hz 0 98G 11ms cycle Weight ST Net 3 9 kgs 8 6 lbs 4 6 kgs 10 1 lbs Casing Color Mounting 33U door mount Regulatory FCC CE Power aa Auto sensing 100V or 240V AC at 50 or 60Hz via IEC type cord Product 195 x 38 4 x 1466 mm 7 7 x 1 5 x 57 7 inch 195 x 38 4 x 1466 mm 7 7 x 1 5 x 57 7 inch The company reserves the right to modify product specifications without prior notice and assumes no responsibility for any error which may appear in this publication All brand names logo and registered trademarks are properties of their respective owners Copyright 2013 Synergy Global Technology Inc All rights reserved P 6 www rackmountmart com
3. Fois Global Technology Inc SH www RackmountMart com Toll Free 1 888 865 6888 Tel 510 226 8368 Fax 510 226 8968 Email sales RackmountMart com User Manual 33U Door Mount Basic Fan Panel FE ce REACH RA401 7 6 RA401 7 9 Legal Information First English printing October 2002 Information in this document has been carefully checked for accuracy however no guarantee is given to the correctness of the contents The information in this document is subject to change without notice We are not liable for any injury or loss that results from the use of this equipment Safety Instructions Please read all of these instructions carefully before you use the device Save this manual for future reference m Unplug equipment before cleaning Don t use liquid or spray detergent use a moist cloth E Keep equipment away from excessive humidity and heat Preferably keep it in an air conditioned environment with temperatures not exceeding 40 Celsius 104 Fahrenheit m When installing place the equipment on a sturdy level surface to prevent it from accidentally falling and causing dam age to other equipment or injury to persons nearby E When the equipment is in an open position do not cover block or in any way obstruct the gap between it and the power supply Proper air convection is necessary to keep it from overheating M Arrange the equipments power cord in such a way that others won t trip or fall over it M If you are using
4. e excerised when working around spinning fans Keep hair fingers and other small objects away from the spinning blades P 2 www rackmountmart com Installation steps The weight of the unit is less than 5kg so in most cases holes in perforated cabinet doors can be used to mount the unit Lift the unit to the desired position Place attached 6 screws then through the door and tighten them To eliminate bypass air to maximize heat removal from the cabinet cut the air blocking material to the size necessary with cutter or scissors then apply the material to the inside surface of the door with screws or adhesive backing Ensure all open perforations are covered by the material O Connect the power cord to the PDU of the cabinet through the cable entry hole on the rear top of the cabinet If no cable entry on the top the unit may be installed on the inside but the model need to be changed Please refer to P 1 Use cable clip to hold the power cord if necessary Mounting screws ON OFF Button _ _ _ _ _ _ _ _ _ _ _ _ _ _ Perforated Cabinet Door P 3 www rackmountmart com Hanging bracket installation Install the hanging bracket kit on the rear side of the fan panel Hang the unit on the door Place attached 4 screws then through the door and tighten them Follow steps on P3 Hanging bracket kit Mounting screws Perforated Cabinet Door P 4 ON O
5. nstalled on the outside of a cabinet s rear perforated door to im prove extraction of heat from high density cabinet The unit can be attached to most 42U or taller cabinets If aisle is relatively narrow for exterior mounting the unit may be installed on the inside of the perforated door For details please refer to the model table below Model RA4017 6 A RA4017 9 A RA4017 6 B RA4017 9 B Unpacking Front Door Cool Air In Installation Rear door outside Front door inside Front door outside Rear door inside Airflow Extract airflow Intake airflow Intake airflow Extract airflow Rear Door Hot Air Out Purpose Exhaust air out from cabinet Cool air in from aisle Cool air in from aisle Exhaust air out from cabinet The equipment comes with the standard parts shown on the package contents Check and make sure they are included and in good condition If anything is missing or damage contact the supplier immediately Package Content 33U door mount fan panel x 1 pc 6 ft power cord x 1 pc User Manual x 1 pc Optional mounting kit Mounting screw x 6 pcs attached with the unit Air blocking material x 1 pc Hanging bracket kit Part no PT HFBK For installation please refer to p 3 za www rackmountmart com Caution Power off the fans if the door is to be opened for maintenence or service of items within the cabinet The fans have finger guards but care must b
6. wer fluctuation or failure O Use of supplies or parts not meeting our specifications O Normal wear and tear CT Any other causes which does not relate to a product defect E Removal installation and set up service charges Regulatory Notices Federal Communications Commission FCC This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential instal lation Any changes or modifications made to this equipment may void the user s authority to operate this equipment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures MH Re position or relocate the receiving antenna m Increase the separation between the equipment and receiver m Connect the equipment into an outlet on a circuit different from that to which the receiver is connected www rackmountmart com RA4017 Door mount Fan Panel is typically i

Download Pdf Manuals

image

Related Search

Related Contents

Buffalo WLE-2DA network antenna  Hand & Power Tool Safety  FASCICOLO DOCUMENTAZIONE TECNICA ART  Multimètre True RMS (valeur efficace vraie) sans fil  Manual de Instruções Inst. Ráp. HW7000 – rev.5  AeronebTM* Solo  Avis Technique non valide  TH!NK Suite User Guide 20121019.pptx  

Copyright © All rights reserved.
Failed to retrieve file