Home

K401-E user manual - DoorEntryOnline.co.uk

image

Contents

1. Alarm Latch Mode Toggle Mode Relay 2 Can Support Door Bell Feature 12 24V DC 12 18V AC Power Input Specifications User Capacity 1100 Cards PINS Relay 1 1000 Relay 2 100 Operating Voltage 12 24V DC 12 18V AC Idle Current 55mA Active Current 80mA Proximity Card Reader EM Radio Technology 125KHz Industry Standard Proximity Card Read Range 25mm 35mm Wiring Connections Electric Lock Exit Button Menecomecione oomueerataiam Dowrset Relay Two NO NC COM Adjustable Relay Output Time 1 99 Seconds 5 seconds default Adjustable Alarm Output Time 1 3 minutes 1 minute default Lock Output Load 3 Amp Maximum Alarm Output Load 3 Amp Maximum Environment IP66 Operating Temperature 30 C 60 C or 22 F 140 F Operating Humidity 10 90 Non Condensing Physical Zinc Alloy Enclosure Surface Finish Powder Coat Dimensions H 120 x W 76 x D 25 mm Unit Weight 650g Package contents ne S uje aa oo C o on v p L a l aa gg K401 E Keypad ee Diode IN4004 For relay circuit protection aT EMI self Ta pping Screws Wall Anchors Manager Add Card Manager Delete Card Screw Driver amp INSTALLATION e Remove the back cover from the unit e Drill 2 holes A C on the wall for the screws and one hole for the cable e Knock the supplied rubber bungs to the screw holes A C e Fix the back cover firmly on the wall w
2. Alarm Output options If there are 10 invalid cards or 10 incorrect PIN numbers in a 10 minute period either the keypad will lockout for 10 minutes or the alarm will operate for 10 minutes depending on the option selected below Normal status No keypad lockout 0 Default or alarm fepatiosot momoe E Alarm output time To set the alarm output time 1 3 Default is 1 minute 1 3 minutes available Acoustic Signal The acoustic signal can be set on or off When on the keypad will bleep when the key buttons are pressed when off the keypad will be in silent Normal status On 6 Default Acoustic signal Off Change Relay 2 to Door Bell When there is no need to operate a second door relay 2 can be set to operate as a door bell The wiring is connecting the door bell to COM2 and NO2 Press and the keypad will send the signal to the door bell Relay 2 Default Door bell 19 To remove The Alarm To reset the Door Forced Open Read valid card or Master Code warning To reset the Door Open Too Long Close the door or Read valid card or Master Code warning Others Using Master Cards Using Master Card It is only available for relay 1 Add a User Card 1 Read Master Add Card 2 Read User Card Repeat Step 2 for additional user cards 3 Read Master Add Card Delete a User Card 1 Read Master Delete Card 2 Read User Card Repeat Step 2 for addit
3. PIN user 3 or 3 just delete the card To set users for relay 2 4 2 The operation is the same as relay 1 To set Card user only in this mode users can only be valid by card or fob To set Card user only 4 1 2 Relay 1 a 2 2 Relay 2 Entry is by Card fob only Relay Setting Pulse mode Toggle mode Pulse mode Factory default Pulse mode Door relay time For Relay 1 5 a Fy setting For Relay 2 5 2 Fy The door relay time is between 1 99 seconds the factory default setting is 5 seconds 1 means relay 1 2 means relay 2 Toggle mode Toggle mode For Relay 1 5 ia 0 For Relay 2 5 2 0 Door Alarm Acoustic Signal Door Bell Settings Door Open Detection Door Open Too Long DOTL warning When used with an optional magnetic contact or built in magnetic contact of the lock if the door is opened normally but not closed after 1 minute the internal buzzer will bleep automatically to remind people to close the door and continue for 1 minute before switching off automatically Door Forced Open warning When used with an optional magnetic contact or built in magnetic contact of the lock if the door is forced open the internal buzzer and alarm output will both operate To disable door open detection 6 0 Default To enable door open detection 6 1 It is optional to connect the D_IN line to LOCK1 or LOCK 2 Keypad Lockout amp
4. 24v DC Power Supply 240v 5 amp Fused Spur Supply TO EXIT Optional exit button To gate controller Comments Relay 2 can be used to operate a doorbell if there is no need to operate a second door The wiring to connect the doorbell is via NO2 and COM2 Press the K401 E will send out a switching signal to the doorbell as long as you press the the doorbell will operate it will stop when you release the Function Description Relay operation Pulse mode and Toggle mode Both relays can operate in Pulse Mode suitable for access control or Toggle Mode suitable for arming disarming alarms switching lights machines etc Every time a valid card fob is presented or a Pin input is made in Pulse Mode the relay will operate for the pre set relay pulse time Every time a valid card fob is presented or a Pin input is made in Toggle Mode the relay changes state which will not revert until a valid card fob is re presented or a Pin input is re made Master Card The K401 E can use Master Cards to program user cards fobs into and out of the system There are two pre programmed Master Cards an Add Card and a Delete Card to allow rapid card enrollment They are for Relay 1 only Anti Tamper Alarm The K401 E uses an LDR light dependent resistor as an anti tamper alarm If the keypad facia is removed the tamper alarm will operate PROGRAMMING Configure the Keypad Change the configure settings acco
5. K401 E External Stand Alone Keypad amp Proximity Card Reader User Manual INTRODUCTION The K401 E is a two relay multifunction standalone access control keypad suitable for either indoor or outdoor use It is housed in a strong sturdy and vandal resistant Zinc Alloy electroplated case The electronics are fully potted making it extremely weather resistant and conforming to IP66 It supports up to 1100 users in a Card PIN or a Card PIN option The inbuilt card reader supports 125KHZ EM frequency card or key fob and the Pin length is 4 6 digits Both relays can operate in Pulse Mode suitable for access control or Toggle Mode suitable for arming disarming alarms switching lights machines etc The K401 E has many extra features including block enrollment anti tamper alarm amp backlit keypad buttons These features make the K401 E an ideal choice for door access not only for small shops and domestic households but also for commercial and industrial applications such as factories warehouses laboratories banks and prisons Features Weather resistant to IP66 Strong Zinc Alloy Electroplated anti vandal case Vandal resistant Backlit Keypad buttons Multi color LED status display Two Programmable Relay Outputs Relay 1 Up to 1000 Pin amp Card holders Relay 2 up to 100 Pin amp Card holders Card Block enrollment Integrated Alarm Buzzer amp Output Low power consumption 55mA Anti Tamper
6. i Short Single seep entry Gramted for Reay 1 on o Sr nl Beep entry GrantedforRewy2 o a o alarm moe Engaged reig am K401 E Simplified Instruction Enter the Programming Mode Master Code 666666 Is the default factory master code Change the Master Code O New Master Code Repeat New Master Code code 4 6 digits Add Card User 1 Read Card for relay 1 2 Read Card for relay 2 Add PIN User 1 User ID 1 1000 PIN for relay 1 1 User ID 1001 1100 PIN for relay 2 The PIN Is any 4 6 digits between 0000 999999 Delete User 3 Read Card 3 User ID How to be granted access Card User Present card fob PIN User Enter PIN
7. ional user cards 3 Read Master Delete Card Reset to Factory Default This will reset the K401 E to the factory default but all card PIN information will still be retained This will also require reprogramming of the Master Add and Delete Cards WOTE This is useful if the original Master Add and Delete Cards have been lost 1 Power down the K401 E 2 Press the Star button and hold at the same time power up the keypad 3 Release the button and wait until the amber LED shines Parts 4 amp 5 must be undertaken within 10 seconds 4 Present any 125KHz proximity EM card or the Master Add Card provided to the K401 E This card is now the Master Add Card 5 Present any 125KHz proximity EM card or the Master Delete Card provided to the K401 E This card is now the Master Delete Card When the red LED begins to blink the K401 E has been successfully reset Erase all Users This will delete ALL User data for relay 1 or relay 2 as per below 1 Enter Program Mode Master Code 2 Enter 30000 for relay 1 Or 90000 for relay 2 3 Exit All configuration data is retained Sound and LED indication Operation Status RedieD Green LED Blue LED Sounds Poneron Pasning S S Store Sng ey standby a O S Erter master Code Entry Node on Srortsnge seep Fin program mode on ergeren Short Single Beep Entered Program Step Single Flash Short Single Bleep Successfully EE ens Ext Programming Mode Fas
8. ith 4 flat head screws e Thread the cable through the cable hole B e Attach the unit to the back cover Wiring cable Wire Insulation Colour Notes 12 24V DC 12 18V AC Regulated Power Input Black 12 24V DC 12 18V AC Regulated Power Input Grey amp Black Negative Pole NO1 Normally Open Relay 1 output NC1 White COM1 Common Connection for Relay 1 Output Green Normally Closed Relay 1 Output Yellow OPEN1 Request to Exit input 1 Advanced Input and Output Features Relay 2 Connection Diagram Examples Common power supply for magnetic lock Fail open power to lock N Y V V VY YN Kee Baa A cloyf nite Blue AG r2e0 12v or 24v DC PSB 1 JOpen C N O NC 12v or 24v DC Power Supply N C or 3 PRESS 240v 5 amp Fused Spur Supply Ensure magnetic lock is set to 12v or 24v dc operation before testing Optional exit button Common power supply for lock release Fail secure power to unlock ay Y Y VY Y Reed Asie Neo Nyni AK Bue Nereeg 12v or 24v DC Open C N O N C PSB 1 12v or 24v DC Power Supply 240v 5 amp Fused Spur Supply TO EXIT Ensure lock release is set to 12v or 24v dc operation before testing Optional exit button Common power supply for auto gate controller using Normally Open contact ie ls lias lings ins ls Ked AM Bia AW llow white JK Bue 12v or 24v DC Open C NO NC PSB 1 12v or
9. lly identify the card of relay 1 or relay 2 continuously without exiting programming mode To delete Card users by user ID 8 Enter the This option can be used when a user has lost their card To delete card users by card 9 Input 8 digits or 10 digits Card number number Cards can be deleted continuously without exiting from programming mode To set users for Relay 2 4 2 0 To set Pin user for relay 2 is the same as relay 1 accept the ID number is 1001 1100 for relay 2 To set Card user for relay 2 is the same as relay 1 with the exception of adding Card users with auto generated ID numbers and Block enrolment as below To add Card Users Method 1 2 Read Card Auto generated ID numbers Card can be added continuously without exiting programming mode Card and PIN Mode To set users for relay 1 4 ES ES To Add a card and Pin user Add the card as for a card user The PIN is any four six digits Press to exit from the programming mode between 0000 amp 999999 with the Then allocate the card a PIN as follows exception of 1234 which is reserved To change a PIN in card and PIN mode Method 1 Note that this is done outside programming mode so the user can undertake this themselves To change a PIN in card and PIN ID number Old PIN mode Method 2 Note that this is done outside programming mode so the user can undertake this themselves To delete a Card and
10. or It is ok to enroll the same card fob or PIN for both relay outputs Factory default setting Card or PIN mode To set users for Relay 1 4 1 0 To add PIN users a ie it The ID number is any number from 1 1000 The PIN is any 4 6 digits between 0000 999999 with the exception of 1234 which is reserved Users can be added continuously without exiting programming mode as follows 1 User ID no 1 f PIN User ID no 2 PIN To delete PIN users 3 Fy Users can be deleted continuously without exiting programming mode To change the PIN of a PIN user Note This step must be done out of programming mode To add Card Users Method 1 ia l This is an easy way to enter Cards can be added continuously without exiting programming mode cards with auto generated ID numbers The ID number will start from 1 if no user has been programmed To add Card Users Method 2 ff a This is the alternative way to The ID number can be any number from 1 1000 enter cards using User ID Allocation In this method a User ID is allocated to a card Only one user ID can be allocated to a single card To add a series of cards users 2 m 8 digits or 10 digits Card numbe Fy Block Enrolment Fy The card number must be Card quantity is between 1 1000 consecutive This operation is only for relay 1 To delete Card users by cards 3 Read Card Note Users can be deleted The device can automatica
11. rding to your application optional Multiple configuration settings can be changed at one time Enter program mode change the desired settings then exit program mode Set Master Code The 4 6 digit Master Code is used to prevent unauthorized access to the system To interface with the K401 E the administrator will need a Master Code Factory default code 666666 We recommend immediate update and recording of your Master Code Programming Step Keystroke Combination 1 Enter Program Mode Master Code 2 Update Master Code 0 New Master Code Repeat New Master Code SET ACCESS CONFIGURATION e Card or PIN Default The User must present a valid card fob to the K401 E or enter their PIN code followed by the key in order to be granted access e Card PIN The User must first present a valid card fob to the K401 E and then enter their PIN code followed by the key in order to be granted access Programming Step Keystroke Combination 1 Enter Program Mode Master Code 2 Card or PIN Default Relay 1 410 Relay 2 420 3 Card PIN Relay 1 Relay 2 4 Exit Program Mode eG User Settings To enter the programming mode To exit from the programming mode Note that to undertake the following programming the Master PIN must be entered Note When adding users if the card fob or Pin user has been enrolled already you can not add it again on the same relay or the device will give a bleep as an err