Home

User manual - Solaire Heating Products Ltd

image

Contents

1. Symbols in the display alpharemote Return lunch Return Night time On 3 On 5 Off 6 System on Flashing Manual override Timing mode Program flame calling setting for heat On off frost protection button Timer setting button Program setting button Confirmation and return button Reset to default settings Increase upwards Decrease downwards Week days 1 7 Actual time and pregrammed time AM PM when in 12 hour mode Requested room temperature 12 Low battery indicator 13 Temperature shown in C or F O 0NDQUIELWNHE PE hm 17 Other Sol Aire products and accessories for electric heating Electric cartridge heaters without control HB V120 QM Electric and central heated towel rails 18 For further alpha remote accessories components and other devices from the field of electric heating also consult our website or contact directly with us We are always happy to help Technical Data Voltage 230V 50 Hz Protection class css White RAL9010 TASTE Black RAL9005 Power Amps Weight and Dimensions of the Radiators E Product Code Overall dimension Incl LxWxH mm packing Colour Code EMEN 787 x 82 x 400 8 7 1337 x 82 x 400 10 9 12 5 1637 x 82 x 400 Wireless battery powered 100m range no obstacles 6 buttons 1 reset Frequency 433 MHz operation at 0 to 50 C storing at 10 bis 60 C Case white
2. Dimension 19 alpha Electric panel radiators Sol Aire Heating Products Limited New Row S ol Air Heating Products Ltd Eppleby eating Products North Yorkshire DL11 7AW Tel 01325 717899 Fax 01325 718065 email info solairehp co uk Web www solairehp co uk 20
3. Should the unit need to be removed from the wall then proceed as follows First disconnect the appliance from the mains Now you can then access up behind the unit to the two upper vertical struts and press there the same time the two movable tabs to the right until it clicks button up fig 1 Now the device can be taken from the holder pe X Fig 1 Fig 2 Fig 3 Note To release the unit from the wall bracket Press the top tabs in together Fig 1 The heater can then be dropped forward and lifted clear of the bracket Please ensure the heater is disconnected from the electricity supply before removing the heater from the wall bracket Preparing the Remote Control mounting installation and battery replacement Wall mounting mounting screw Ered ooma tion Table stand for remote control Optional Accessory Inserting the batteries Procedure prior to first use or when changing batteries e Remove the two screws at the bottom Batterv Cempartment Open short side of the remote control Lift the display face carefully e 2 alkaline batteries 1 5 V IEC LR6 AA e Insert the 2 batteries in the compartment e Note the correct polarity and carefully close and replace retaining screws 2 Screws 1 Basic settings of the remote control Turn On the flame and clock icon is seen in the display Remote On Off button 1 1 Press the clock button 2 2 Use the A or V button 6 7 to set the exact
4. a single remote control Adjustment for operating multiple devices with multiple remote controls Effective wireless rane Programming the remote thermostatic controller Temperature setting without time control 1 eee eee eere eene ene eene nnne ne Important information about the temperature setting without time control Time controlled temperature settings pni NM C EMI E Time controlled temperature settings with sedead default iilis M Frost protection OO oec tius daw see vv vvv T aa edes eat eui D E OPER urs aia Holiday mode and manual override 1 eee eere eee eee eee eene nennen sec ezzenionionio Blank program input sheet nsi nete via verre goto vi edel vex Ya rav eva Dr deb Xa EON EVE Ce eta E RUE d Control screen schemiablit octo eine S YEAR ARR ARA ARR E Eee aV RS E RARE VE IRE E ULEUS More products from SO AIFe iie c rie bita a o aon et aes olipha technical data Sheet usvassp aes nav Fo non 8 RU S eun SRP E Ux nERR SESEnIS EE Eu Soa Pa CU V Your new alpha electric panel radiators Thank you for purchasing the alpha Panel Heater which is a modern and high quality device Please check carefully the heater once you have unpacked the unit our production facility strives to pack and ship for the ultimate in protection If you do happen to experience a problem pl
5. calling for power Green LED B will also flash slowly to indicate when the heater is in an over temperature protection mode Pairing yellow LED C The yellow LED will illuminate when to show it is ready for pairing Before commencing with pairing make sure the heater is switched on at the righthand side The white switch should be pointing to the I symbol For pairing a single heater with a single remote control 1 Ensure the heater is turned on at the side and the control screen has batteries installed and is turned off showing system 1 1 After switching the heater on via the main switch there should be no LED lights on the side of the heater If the red LED is on turn it off by depressing the small on off receiver power switch The heater is now ready for pairing with the remote control 1 2 Press and hold the on off receiver power switch for 3 seconds until the yellow LED lights up 1 3 Take the remote control turned off and hold it a short distance from the heater control Now press the R button 4 on the bottom left hand corner for 5 seconds 1 4 The back light on the screen will illuminate when the heater is paired 1 5 Turn the heater red LED on by depressing the small on off receiver power switch Then turn the control screen on at the top left hand corner and increase the room temperature setting to maximum The green LED on the heater will then illuminate to show the heater is calling for power 1 6 Reve
6. embedded in a foam covering for protection e Abagof screws and plugs for wall mounting e Installation and operating instructions Not included e Alkaline Batteries for Remote Control 2 x AA LR6 Safety instructions and warnings Instructions prior to installation Before you begin the installation setup or operation of the unit please read these instructions carefully and proceed following the guide and technical instructions The manufacturer supplier cannot accept liabilty for any eventuality if you fail to observe warnings present in the installation and operating instructions It cannot be stressed enough that if you do not feel capable or are unsure working with electrcity please always seek the advice or services of a professional The unit has to be installed the correct way up and this is marked on the cabinet Another pointer being the power cable will exit from the right hand side The unit should only be operated by a competent adult and it should be never left unsupervised where children could access and use the controls Before connecting the appliance ensure the cabled is connected with the correct fuse protection and again if in doubt consult a professional The connection must only be connected to a supply including a ground earth wire also called Class 1 and marked by this icon D After installation Any faults that may develop in the future must always be repaired by a certified professional otherwi
7. right front of the remote side of the display there is a small hole 5 for the reset return to factory setting In the event that a factory reset is necessary use a corresponding object such as a straightened paper clip and run this gently into the slot and press so that the inner knob Remove the item carefully back from the opening The remote control is now reset to the factory delivered state Operation of alpha remote heater without the remote control Although the alpha heater is designed to run in conjunction with the remote control screen there may be instances where the heater needs to be used without the screen This should be only in emergencies or for short periods of time This could be due to the following e Forgotten to buy batteries despite the low battery indicator flashing e Control screen is missing or damaged In these circumstances simply turn the power on to the heater at the main switch at the rear With the red LED turned off push and hold the receiver on off button for 10 seconds Keep it pushed in even when the yellow LED pairing light illuminates until the green LED lights up denoting calling for power Remember the heater is under no external control whatsoever and is your reponsibility to switch it off manually 15 Finallv check vour program inputs Before you can run a program with newly entered data you should be sure that everything has been entered as it was planned Always check before exec
8. 77 e ST adjusted by 3 C or down 35 C 95 F temperature 20 C 68 F C p Fa _ FA sL_ Heat option for fast or slow 00 __ PP 00 Thisoptionisnotpossibleinalpha 24 12or24_ Selecti2or24hourdispay P6 PA P Twoswitchingtime settingsselectable 8 J j0 S 10 Mode backlight selectable nj 5 6 8 9 Utilizing the settings 1 The calibrated measured temperature is displayed on the remote control 16 and can be adjusted by 3 C 2 Upper temperature limit is displayed and can be adjusted between 18 C 64 F and 35 C 95 F Factory setting is 35 C 95 F 3 Lower temperature limit where the desired lower adjustable temperature limit can be entered between 5 C 41 F and 20 C 68 F Factory setting is 5 C 41 F 4 For F or C displayed option can be selected here 5 Option for fast or slow heating For quick heating use the FA selection In this mode the heater will react immediately when the desired temperature is 1 C above below the set room temperature For slow heating use the SL selection In this mode the heater will react immediately when the desired temperature is 3 C above below the set room temperature 6 This feature is not available on the alpha 7 Display for times Choice between 12 and 24 hours mode 8 Three program options for switching points and temperature per week to choose from Selec
9. English User manual alpha Electric panel radiators Doc Code INSAHDE001 04 2014 Index Your new alpha electric panel radiator eere crecen enne PILisfori eem eS DENUVO PR TITTEN De REN Safety instructions and warnings eese eee eee ee eene nnn nnn nno sen teret nno Instructions prior to installation eeee e eene eee eee eee nene rne roro sen neret conici eneoneoo cAlter installatio ni illa SATS OW Cl acl OM cic laid Mounting locatio i e lei alan Wall mounting the Alpha Heater eeeee eee eene eene enne ene ren neenon nno Remote thermostatic controller Use of wall mounted or table stand optional and battery installation Basic settings of the remote control c eeeeee eee eee eere eene nennen cesena enano Current day of week and time setting eLeeeeee esee eee eee eee eee eere nennen nae tnn sno ene senzene Contig ration mend 0 eoo iib vr RRREF CREE ddp axi a oss o Cav ua bn vx EUR e EE Ded acu Doa Ua ua Priamum N A Commissioning and pairing the heater to the control screen Pairing between transmitter remote control and heater receiver Adjustment operation with remote control cccsscescescescceceecesccecccesceccecsceccscncecceceseecess Adjustment for operating multiple devices with
10. current hour 3 Press the clock button 2 again and the minute digits will flash 4 Use the A or V button 6 7 to set the exact current minute 5 Press the clock button 2 again and the day of the week indicator 8 will flash 6 Use the A or V button 6 7 to set the current day of the week 1 Monday 7 Press the R button 4 and the entries will be stored 2 Configuration Menu The remote control has a configuration menu where the various basic parameters can be set depending on the preference of the users and their habits Proceed as follows Press the button 1 to ensure that the remote control is in antifreeze mode A cold symbol 14 must be visible on the screen Now press the P 3 for about 3 seconds to move to the input mode of the configuration menus The large figure shown is setting number the small figure to the right is the adjustment for this setting By pressing the arrow keys 6 7 you can adjust the options until the desired selection is displayed Pressing the P key again the displayed value is assumed for these parameters and the display changes to the next parameter Continue selecting until all 10 parameters are defined according to your wishes To exit from this menu press the Start button 1 and return to the freeze protection mode or for program execution press the R key 4 and enter run mode If no key is pressed for 20 seconds the parameter menu is automatically exited Default Settings v Oe 7
11. d it must be in a such a position that the ventilation convector vents at the top and bottom of the unit must be free of any obstruction Careful consideration needs to be given to curtains and as mentioned earlier never be tempted to dry clothes over the unit The unit operates on the same convection pinciple as a conventional central heating radiator Allowing free air flow will give the best and safest performance Should you be in doubt as to the material above the unit and its chosen position in relation to the heater and how heat resistant it is seek further help from a professional Wall mounting the device AN The appliance must not be connected to the electricity whilst fitting to the wall brackets Place the heater with the front panel on the ground ensuring the surface you are placing it on will not damage the heaters finish If in doubt place a soft cloth down first To release the wall bracket press the top part of the bracket on both sides at the same time the metal tabs slightly to the left Fig 1 and hang the unit on the upper fixing of the wall bracket Now lower the unit onto the base lugs of the brackets With the air vents to the top lower the heater into the bottom hooks Fig 2 The centre tabs of the bracket will then locate into the slots before the top tabs will locate and lock Fig 3 Press the device now facing the wall then snap the two movable plate tabs and the device is attached to the wall bracket
12. ease contact ourselves during working hours with your query Our contact details and relevant contact information can be found on the back of this installation along with operating instructions Keep these installation and operating instructions along with any other documents in a safe place for further reference Disposal Packaging The packaging serves to protect it from damage during transportation Please be aware of the danger to young children regarding polythene and other packaging meterials and dipose of it in a safe place AN Suffocation warning for polythene films and folding cartons Some packaging materials used are environmentally friendly and recyclable Please dispose of the packaging environmentally friendly manner Use the appropriate means of disposal if in doubt contact the appropriate agencies or councils Disposal of the appliance fl fmi Waste raw materials can often be recovered for re use please recycle whenever possible This device complies with the European Community 2002 96 EC of the WEEE Directive This Directive lays down the framework for an EU wide collection and recycling of electrical and electronic equipment Delivery Check immediately on receipt of the unit the contents of the package The following items must be included e Complete electric Alpha panel radiator with wall mounting bracket all in the correct colour ordered e Remote control if ordered in a separate box
13. rt to your chosen temperature settings 11 When operating multiple devices with multiple remote controls When using more than one remote control you will need to give each control specific assignments to avoid any malfunctions to individual units This is done by assigning corresponding codes by remote control Please proceed as follows Open the casing of the remote control by removing the two small screws You will see a bar with 8 selectors see illustration below In default all switches are set the same for delivery Simply slide one or more of the switches up to make your own unique code for the multiple heaters used from one screen The screen sets the frequency the heaters will accept this and only work through this controller After these changes close the cover of the remote control again and make the match between unit and remote control before as described above 8 dial switch 8 dial switch Notel The range of the remote control in an open area is about 100 m In buildings the range is significantly shorter and depends on many factors On average a range of about 40m typically unless specifically screened by for example Metal or another interference field Note Settings saved in the remote control are not lost when changing the battery as it is equipped with an EPROM 12 Setting the heater by remote control after pairing is complete For an explanation to the symbols seen on the
14. screen of the remote control please refer the end of this manual Temperature only setting without time control 1 Turn on the remote control at the top left hand corner of the screen 2 Increase the temperature setting in the top right hand corner of the screen to your desired preference This can be done in 0 5 C increments by pushing the up arrow 6 The hand symbol is visible on the display showing it is working in manual operation 5 The green LED on the heater will illuminate to show it is calling for power 6 To exit the manual operation either simply turn the control screen off in the top left hand corner or push the R button to revert to the timed mode Note a The manual temperature adjustment is active until the next input automatic switching time is achieved The controller then switches back to timed operation b You can prevent this from happening by pressing the R button for 3 seconds until the symbol of a key 18 appears below the figure for the current day of the week This means that the automatic program is temporarily suspended and the manually set temperature request is executed This continues until the R key 4 is pressed briefly The key symbol disappears and the automatic scheduled expiration is now reinstated Temperature setting with time control For a time controlled temperature setting with predefined default values proceed as follows The remote control includes a factory preset default If
15. se there is a risk of possible serious consequences To ensure quality and safe operation it is advised that manufacturer recommended parts are always fitted If there is any damage to the power cable please check with a professional if you are in any doubt whatsoever please do not use the heater Never be tempted to remove screws and open the unit yourself whilst the cable is connected to the electrcity supply Proper use of the electric heater e Do not install or use this heater outdoors e Suitable for space heating only Not for washing drying etc use fire hazard e Ventilation openings on the rear of the unit should never be covered Structures such as Window sills etc should be at least 150 mm vertical spacing above the device e The heater should be mounted a minimum of 100mm from the floor height e Consideration must be given when fixing the heater wall bracket to different wall constructions Ensure the correct fixing plugs are always used for a given material e Ensure the wall bracket is mounted correctly and is completely level e Never use the unit without the attached brackets e Never allow liquids to enter the unit or remote control e Clean the outside of the heater and remote control with a damp cloth only e When not in use it is good practice to have the heater switched off at the main switch e Never allow children to play on or with the unit or remote control Mounting Location Once the unit is mounte
16. t 7 All 7 days can be individually programmed Select 3 You can program three periods 5 weekdays Saturday Sunday Select 0 No model programmed The factory setting is 7 9 Two options for switching times per day Choose P4 You have 4 switching times per day of the program Select P6 You have 6 daily times The factory setting is P6 10 The backlight of the display has 3 settings 0 No backlight 5 backlight for 5 seconds 10 backlight for 10 seconds Commissioning Now that the remote control has been prepared and the device is attached to the wall the connection can be made to the mains This is done either by simply plugging the power cord into the outlet or by fixed wiring in a junction box The latter must be executed by an appropriate qualified professional If the connection to the mains supply and the device is to be operated please proceed as follows 1 2 3 Heating ontrol 1 On Off Anti frost 5 Reset main switch 2 Clock Receiver B power green LED Display A Red LED 10 Wireless remote control 3 Program Set 4 Confirmation program Sh pid PAO 5 Reset Receiver on off button A Selection up Display C Yellow LED 7 Selection down 5 6 7 Receiver power button red LED A A short press will turn the red LED on off indicating supply status Load staus green LED B The green LED will illuminate when the heater is
17. time to end the first programme e Now push the clock button 2 to set the temperature required when the heater is off e This can be set as low as 5 C meaning the heater will only activate should the room temperature drop below this figure If you would like to reduce this further see the configuration menu on page 8 of this instruction e Follow the guidelines above through every day until complete e f you wish to escape this menu at any time simply push the R button Frost Protection mode Simply turn the rempote control screen off in the top left hand corner The screen should be showing the time current room temperature and system This will leave the heaters off their set programmes and only activate should the room temperatures fall below 5 C 14 Holiday Mode e With the screen turned on push and hold the P key 3 for 3 seconds e Asmall suitcase will appear in the top of the screen indicating the holiday mode is active e Push the clock button 2 to increase the number of days required up to a maximum of 99 days e The P key 3 can be pushed to reduce the amount of days e Now set the desired temperature by pressing the arrow keys 6 7 on the value that you want to keep in your absence The factory setting is 10 C e Finally press the R key 4 to record the set data e When the set days of absence are finished the controller will automatically return to the programmed operation Reset Function On the
18. uting the entries Press the P key 3 It will now show the set input information for each on off and day If the entry is correct press the P button 3 You can also make changes and then press the P key Proceed as explained in previous chapters the entire input for the week The chart below can be filled in to remind you of your new default settings j SA 2f Ha it Q T e fu he m if Leaving home1 Return 1 Leaving Home 2 Return 2 Nights Sleep Temp Stop Temp Temp Start Temp Value Time Value Value Time Value Start Temp Start Time Stop Time Temp Value Stop Time VA i c n General Technical Voltage 230V 50Hz Class 1 must be fully earthed Protection class IP20 not for use in bathroom zones 1 or 2 Colours RAL 9010 white RAL9005 black Both 30 polyester matt Remote control 2x1 5V IEC LR6 AA alkaline batteries Battery warning indicator Error warning signal loss Frequency 433MHz 16 1 2 3 4 Frost Protection K Sytem Error Actual room temperature EA o EA Ni C Sytem lock Scheme number Schematic drawing for alpharemote 18 T e Ap Mi SETTING 17 cf EO CO CU CU PR 11 VICE sla f 7 F DALE Og 1 2 d 2 e 2 47 a9 8 UL 13 6 SYSTEM NG S ET FEST LS 7 BE O BR 14
19. you are satisfied with the predefined default values shown in the table below and you do not want to change anything simply press the R button 4 on the remote control The control will return to the default operating state The following values are set t it Ta Ta YE d Q iB 7 Ra Re Tha Ti Leaving home 1 Return 1 Leaving Home 2 Return 2 Nights Sleep Start Temp Start Temp Start Temp Start Temp Start Temp Start Temp time value value value value value value value value value value value 13 If however you would like to change any individual or indeed all preset values please follow the instruction below e Firstly decide if you would like to use the factory settings with 3 x on off each day or your own bespoke settings with 2 x on off each day To change the factory default see the configuration menu on page 8 of this instruction e Turn on remote control at the on off button 1 e Press the P key 3 1 will appear in the screen indicating the first On e Thetime will be flashing at the top of the screen This can be adjusted up or down by pushing the keys 6 7 e When your time is set push the clock button 2 This will save the start time and move across to the temperature required e This can again be adjusted by pushing the keys 6 7 When this is complete push the P key 3 to move across to the next programme e 2 will now be flashing indicating the first off setting e Firstly set the

Download Pdf Manuals

image

Related Search

Related Contents

manual - LC  LogisMag n°24    Samsung BD-D5100 Инструкция по использованию  AT10G RD 取扱説明書  Met One 6000 Partikelzähler  VIAFLO ASSIST Operating instructions  Industio C114HI User`s Manual  データ転送ツール 取扱説明書 (インストール編)  

Copyright © All rights reserved.
Failed to retrieve file