Home
        User`s Manual
         Contents
1.                  Manuals    The following shows manuals relevant to this product        Detailed Manual             Manual Number    Manual name  Model code        GT16 User s Manual SH 080778ENG           Sold separately   1D7M88   GT15 User s Manual SH 080528ENG    Sold separately   1D7M23   GOT1000 Series Connection Manua SH 080532ENG    Sold separately   1D7M26                    Relevant Manuals          For relevant manuals  refer to the PDF manuals stored in the GT  Designer2 CD ROM                 2005 MITSUBISHI ELECTRIC CORPORATION    Compliance with the EMC and Low Voltage  Directives    When incorporating the Mitsubishi GOT into other machinery or  equipment and keeping compliance with the EMC and low voltage  directives  refer to  EMC AND LOW VOLTAGE DIRECTIVE  of  GT15 User s Manual    The CE logo is printed on the rating plate of the GOT  indicating  compliance with the EMC and low voltage directives     Packing List    The following items are included                    Model Product Quantity  Bus connection unit 1  GT15 QBUS     GT15 ABUS Mounting screws set  2 screws  2 1  stickers   Bus connection unit 1       GT15 QBUS2   Mounting screws set  2 screws  2  GT15 ABUS2   stickers        Extension interface relay board 1                                                          Item GT15  GT15  GT15  GT15   QBUS QBUS2 ABUS ABUS2  IN 1 1 1 1  Connector  OUT   1   1  16 points 32 points  I O occupied points  I O assignment   I O assignment   16 intelligent points
2.          1  Overview       This User s Manual describes the GT15 bus connection unit   hereafter abbreviated to the bus connection unit     Use the bus connection unit for making bus connection of the  GOT  Refer to GT16 User   s Manual or GT15 User s Manual for  the applicable GOT        2  Specifications       The performance specifications of the bus connection unit are  indicated below    The general specifications of the bus connection unit are the  same as those of the GOT    Refer to GT16 User   s Manual or GT15 User s Manual for the  general specifications of the GOT                    Kem GT15  GT15  GT15  GT15   QBUS QBUS2 ABUS ABUS2  Interface QCPU  Q Mode  QnA ACPU  bus connection bus connection                   3  Part Names and External Dimensions        1  GT15 QBUS  GT15 ABUS                     107 4 13                                    2  GT15 QBUS2  GT15 ABUS2                                                                                                                                     E     Model A B Cc D  23 12 31 5  GT15  QBUS  0 09     0 47     1 24  g  2 5 1 29 33 5  GT15  QBUS2  0 10     0 43     4 44     4 32   45 15 29 5  GT15  ABUS  0 18     0 59     1 16  i  45 1 31 31  GT15  ABUS2  0 18     0 43     4 22     4 22   Unit  mm  inch   Dimensions of X when the bus connection  unit is mounted to the GOT  GOT GT16 GT15  15   19 5  0 78    21  0 83   12 1  18  0 71    18  0 71   10 4  21  0 83   8 4   5 7    z 23  0 92   Unit  mm  inch   No  Name 
3.   Special 32 points   Internal  current 0 44A 0 44A 0 12A 0 12A  consumption   5VDC      0 13kg 0 14kg 0 13kg 0 14kg  Weight  0 291b     0 31Ib     0 291     0 31Ib     When the GOT power is on  the internal current consumption is    included in the current consumption of the GOT   When the GOT power is off  the internal current is supplied from  the power supply of the PLC system     Select the used bus connection unit according to the  connection target and connection position    lt Bus connection unit selection example gt      1  Select the bus connection unit according to the  connection target          QCPU  Q Mode   motion controller Q series    GT15 QBUS GT15 QBUS2    ACPU  QnACPU  motion controller A series    GT15 ABUS GT15 ABUS2    M  2  Select the bus connection unit according  3 E to the GOT connection position                                                  4     m     m                   Placed midway      GT15 QBUS2 GT15 ABUS2               Placed at end    GT15 QBUS GT15 ABUS  GT15 QBUS2 GT15 ABUS2          When using the bus connection  make the communication  settings to perform communication between the GOT and  PLC Refer to GOT1000 Series Connection Manual for details  of bus connection        When using bus connection unit  use a standard monitor OS and  communication driver of GT Designer2 Version2 15R or later    With a standard monitor OS and communication driver of an older version   the GOT has cannot recognize the unit to perform monitoring        
4. Description       Bus connector    1  Connector for connecting the   IN side     bus connection cable  IN side        Bus connector Connector for connecting the    2   OUT side  bus connection cable  OUT side        Extension connector installed to    3  InlerielCe  Connector a front extension unit or the GOT       Extension connector to which a    4  Extension  connector back extension unit is installed       Mounting screws fixed with a    5  Mounting screw front extension unit or GOT       Screw for fixing the extension    6  Board fixing screw interface relay board                   7  Rating plate            4  Installation Procedure       The method for mounting and removing the bus connection unit is  explained using the GT 15 as an example Refer to the GT16 User s  Manual for the bus connection unit mounting and removal methods  for the GT16      1  GT15 QBUS  GT15 ABUS    1  Power off the GOT   2  Remove one extension unit cover of the GOT        4  Fasten the bus connection unit by tightening its  mounting screws  2 places  with tightening torgue 0 36  to 0 48 Nem        5 When installing an extension unit on the unit that has  been installed  remove the connector cover and the  sticker  When not installing an extension unit on the  unit that has been installed  in order to avoid receiving  electrostatic  stick accessory stickers to cover the top  of mounting screws  2 places   Keep the connector  cover fixed  Keep the sticker stuck as it is                 Accessor
5. MITSUBISHI       MODEL GT15 QBUS GT15 QBUS2   GT15 ABUS GT15 ABUS2  BUS CONNECTION UNIT    User s Manual       Thank you for purchasing the GOT1000 Series        Prior to use  please read both this manual and detailed  manual thoroughly to fully understand the product              MODEL GT15 BUS U       MODEL    CODE 1D7M39                IB NA  0800323 F 0810 MEE       GRAPHIC OPERATION TERMINAL    GOTio900     SAFETY PRECAUTIONS       Always read these precautions before using this equipment      Before using this product  please read this manual and the relevant  manuals introduced in this manual carefully and pay full attention to  safety to handle the product correctly  The precautions given in this  manual are concerned with this product  In this manual  the safety  precautions are ranked as  DANGER  and  CAUTION            7 A      Indicates that incorrect handling may cause  d DANGER hazardous conditions  resulting in death or  severe injury           Indicates that incorrect handling may cause  A CAUTION   hazardous conditions  resulting in medium or  slight personal injury or physical damage              en    Note that the A CAUTION level may lead to a serious accident  according to the circumstances  Always follow the precautions of  both levels because they are important to personal safety    Please save this manual to make it accessible when required and  always forward it to the end user      DESIGN PRECAUTIONS   A  CAUTION      Do not bunch the control wires o
6. al  Perseo Ingr 2  Via Paracelso 12  I 20041 Agrate Brianza   Milano  Italy  Tel    39 039 60531   Spain Mitsubishi Electric Europe B V  Spanish Branch  Carretera de Rubi 76 80   E 08190 Sant Cugat del Valles  Barcelona  Spain  Tel    34 93 565 3131   France Mitsubishi Electric Europe B V  French Branch  25  Boulevard des Bouvets  F 92741 Nanterre Cedex  France  TEL   33 1 5568 5568   South Africa Circuit Breaker Industries Ltd   Private Bag 2016  ZA 1600 Isando  South Africa  Tel    27 11 928 2000   Hong Kong Mitsubishi Electric Automation  Hong Kong  Ltd   10th Floor  Manulife Tower  169 Electric  Road  North Point  Hong Kong  Tel    852 2887 8870   China Mitsubishi Electric Automation  Shanghai  Ltd   4 F Zhi Fu Plazz  No 80 Xin Chang Road   Shanghai 200003  China  Tel    86 21 6120 0808   Taiwan Setsuyo Enterprise Co   Ltd   6F No 105 Wu Kung 3rd Rd  Wu Ku Hsiang   Taipei Hsine  Taiwan  Tel    886 2 2299 2499   Korea Mitsubishi Electric Automation Korea Co   Ltd   1480 6  Gayang dong  Gangseo ku Seoul  157 200  Korea  Tel    82 2 3660 9552   Singapore Mitsubishi Electric Asia Pte  Ltd   307 Alexandra Road  05 01 02   Mitsubishi Electric Building  Singapore 159943  Tel    65 6470 2460   Thailand Mitsubishi Electric Automation  Thailand  Co   Ltd   Bang Chan Industrial Estate No 111 Moo 4  Serithai Rd   T Kannayao  A Kannayao  Bangkok 10230 Thailand  Tel    66 2 517 1326   Indonesia P T  Autoteknindo Sumber Makmur  Muara Karang Selatan  Block A Utara  No 1 Kav  No 11 Kawasa
7. n Industri Pergudangan  Jakarta   Utara 14440  P O Box 5045 Jakarta  11050 Indonesia  Tel    62 21 6630833   India Messung Systems Pvt  Ltd   Electronic Sadan NO III Unit No15  M I D C Bhosari   Pune 411026  India  Tel    91 20 2712 3130   Australia Mitsubishi Electric Australia Pty  Ltd   348 Victoria Road  Rydalmere  N S W 2116  Australia  Tel    61 2 9684 7777    A MITSUBISHI ELECTRIC CORPORATION    HEAD OFFICE   TOKYO BUILDING  2 7 3 MARUNOUCHI  CHIYODA KU  TOKYO 100 8310  JAPAN  NAGOYA WORKS   1 14  YADA MINAMI 5 CHOME  HIGASHI KU  NAGOYA  JAPAN          When exported from Japan  this manual does not require application to the Ministry  of Economy  Trade and Industry for service transaction permission           Specifications subject to change without notice   Printed in Japan     
8. ng  always shut off GOT power externally  in all phases  Not doing so can cause a unit failure or  malfunction        CAUTION      Do not disassemble or modify any unit   This will cause failure  malfunction  injuries  or fire       Do not touch the conductive areas and electronic parts of this  unit directly  Doing so can cause a unit malfunction or failure       Always secure the cables connected to the unit  e g  run them in  conduits or clamp them Not doing so can cause unit or cable  damage due to dangling  moved or accidentally pulled cables or  can cause a malfunction due to a cable contact fault     Do not hold the cable part when unplugging any cable  connected to the unit  Doing so can cause unit or cable damage  or a malfunction due to a cable contact fault       Always make sure to touch the grounded metal to discharge the  electricity charged in the body  etc   before touching the unit   Failure to do so may cause a failure or malfunctions of the unit            DISPOSAL PRECAUTIONS     A  CAUTION    Dispose of this product as industrial waste      TRANSPORTATION PRECAUTIONS        CAUTION      Make sure to transport the GOT main unit and or relevant unit s   in the manner they will not be exposed to the impact exceeding  the impact resistance described in the general specifications of  GT16 User   s Manual or GT15 User s Manual  as they are  precision devices  Failure to do so may cause the unit to fail   Check if the unit operates correctly after transportation
9. r communication cables with  the main circuit or power wires  or lay them close to each other   As a guide  separate the lines by a distance of at least 100 mm   3 94 inch  otherwise malfunctions may occur due to noise         INSTALLATION PRECAUTIONS      lt  gt  DANGER         Before mounting or dismounting this unit to or from the GOT   always shut off GOT power externally in all phases   Not doing so can cause a unit failure or malfunction        CAUTION      Use this unit in the environment given in the general  specifications of GT16 User   s Manual or GT15 User s Manual   Not doing so can cause an electric shock  fire  malfunction or  product damage or deterioration     When installing this unit to the GOT  fit it to the connection  interface of the GOT and tighten the mounting screws in the  specified torque range  Undertightening can cause a drop   failure or malfunction  Overtightening can cause a drop  failure  or malfunction due to screw or unit damage         WIRING PRECAUTIONS      lt  gt  DANGER      Before connecting the Bus connection cable to this unit  always  shut off GOT power and PLC CPU power externally in all  phases  Not doing so can cause a malfunction       A CAUTION      Insert and fit the bus connection cable into the connector of the  unit to be connected until it  clicks   After fitting  check for lift  which can cause a malfunction due to a connection fault         STARTUP AND MAINTENANCE PRECAUTIONS          DANGER       Before starting cleani
10. shi products  damage  secondary  damage  accident compensation caused by special factors  unpredictable by Mitsubishi  damages to products other than  Mitsubishi products  and to other duties     A For safe use     This product has been manufactured as a general purpose part for  general industries  and has not been designed or manufactured to  be incorporated in a device or system used in purposes related to  human life      Before using the product for special purposes such as nuclear  power  electric power  aerospace  medicine or passenger  movement vehicles  consult with Mitsubishi      This product has been manufactured under strict quality control   However  when installing the product where major accidents or  losses could occur if the product fails  install appropriate backup or  failsafe functions in the system        Country Region Sales office Tel   USA Mitsubishi Electric Automation Inc   500 Corporate Woods Parkway Vernon Hills  IL 60061  U S A   Tel    1 847 478 2100   Brazil MELCO TEC Rep  Com e Assessoria Tecnica Ltda   Rua Correia Dias  184  Edificio Paraiso Trade Center 8 andar  Paraiso  Sao Paulo  SP Brazil  Tel    55 11 5908 8331   Germany Mitsubishi Electric Europe B V  German Branch  Gothaer Strasse 8 D 40880 Ratingen  GERMANY  Tel    49 2102 486 0   U K Mitsubishi Electric Europe B V  UK Branch  Travellers Lane  Hatfield  Hertfordshire   AL10 8XB  U K   Tel    44 1707 276100   Italy Mitsubishi Electric Europe B V  Italian Branch  Centro Dir  Colleoni  P
11. y     sticker   Connector   l T         cover   t    Sticker     2  GT15 QBUS2  GT15 ABUS2    1  Power off the GOT   2  Remove two extension unit covers of the GOT        3 Attach the extend interface relay board to the extend  I F 2 side on the GOT  After the installation  detach the  connector cover from the extend inter face relay  board For GT155    the extension interface relay  board is not needed    4  Fit the bus connection unit in the GOT case     Remove the connector       5  Fasten the bus connection unit by tightening its  mounting screws  4 places  with tightening torgue 0 36  to 0 48 Nem    6  Fasten the bus connection unit by tightening the board  fixing screws  2 places  with the tightening torque of  0 36 to 0 48 Nem        7 When installing an extension unit on the unit that has  been installed  remove the connector cover and the  sticker  When not installing an extension unit on the  unit that has been installed  in order to avoid receiving  electrostatic  stick accessory stickers to cover the top  of mounting screws  4 places   Keep the connector  cover fixed  Keep the sticker stuck as it is     Connector cover Accessory sticker       Accessory sticker       Point             Remove the screws that fixes the extend interface relay board  before removing the unit  Above 6         Warranty   Mitsubishi will not be held liable for damage caused by factors found  not to be the cause of Mitsubishi  machine damage or lost profits  caused by faults in the Mitsubi
    