Home

PROsine 2.0 Inverter/Charger Quick Reference Guide

image

Contents

1. PROsine 2 0 Inverter Charger Quick Reference Guide January 2006 Xantrex International All rights reserved Disdaimer UNLESS SPECIFICALLY AGREED TO IN WRITING XANTREX TECHNOLOGY INC XANTREX a MAKES NO WARRANTY AS TO THE ACCURACY SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION b ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSS OR DAMAGE WHETHER DIRECT INDIRECT CONSEQUENTIAL OR INCIDENTAL WHICH MIGHT ARISE OUT OF THE USE OF SUCH INFORMATION THE USE OF ANY SUCH INFORMATION WILL BE ENTIRELY AT THE USER S RISK Date and Revision January 2006 Revision B Part Number 445 0089 01 01 Contact Information Telephone 1 800 670 0707 toll free North America 1 360 925 5097 direct Fax 1 800 994 7828 toll free North America 1 360 925 5143 direct Email customerservice xantrex com Web www xantrex com
2. they do not need to be recorded Load Sensing Disabled Load Sense Power 100 Watts Load Sense Interval 1 second Low AC Transfer V 90V Low AC Transfer Hz 55Hz High AC Transfer V 130V High AC Transfer Hz 65Hz AC Series Mode Standalone Inverter Low V Shutdown 10V Inverter Low V Warning 0 5V Inverter Low V Restart Hysteresis INV Low V 2 5V Restrt Hyst Run Without Panel NO Inverter Enabled on Reset Without Panel Disabled Charger Enabled on Reset Without Panel Disabled Auto Restart After Error NO at Adjustable From the Configure Display Panel Menu Audible Alarm OFF LCD Backlight Mode Auto LCD Backlight Brightness 50 LCD Backlight Timeout 20 seconds Temperature Farenheit Adjustable From the Configure Battery Menu NOTE Settings below are for Battery Type Generic Gel Battery Size 200Ah Ha Default Battery Temperature Dflt Batt Temp Warm Battery Type Generic Gel H Battery Temp Coefficient Batt Temp Coeff 27mV C Mode Settings Bulk e Max Voltage e 14 2V e Max Current C 25 e Threshold Voltage e 13 8V e Threshold Timeout e 3min Mode Settings Absorption e Max Voltage e 14 2V e Max Current C 25 e Max Timeout e 8hr e Threshold Current C e 1 e Threshold Timeout e 3min Trademarks PROsine 2 0 Inverter Charger is a trademark of Xantrex International Xantrex is a registered trademark of Xantrex International Notice of Copyright
3. Osine Faults e No Equalize Load Sense Interval LCD Backlight Brightness Battery Type Clear PROsine Fault Log i S Low AC Transfer V LCD Backlight Timeout View Change Battery Details View Last 10 Panel Faults Note This menu itemi only available Low AC Transfer Hz Temperature C F e Battery Temp Coefficient AC Bad Cause View Software Versions e LVP Software Revision e HVP Software Revision e Display Software Revision e Display EEPROM Revision View System Temperatures e Temperature at Panel e PROsine Unit Temp 1 e PROsine Unit Temp 2 PROsine HVDC PROsine 2 0 Errors When an error is active in the PROsine you can access the Clear Errors menu By selecting Yes you tell the PROsine that you have attempted to correct the error condition and the PROsine should attempt a restart Warming Error and Panel Fault Messages The last 20 Warning and Error messages and the last 10 Panel Fault messages are recorded so you can view them for troubleshooting purposes View messages by select ing View Last 20 PROsine Faults or View Last 10 Panel Faults on the Diagnostics menu Some Error messages appear as Internal Error nnnn where nnnn is the number of the error If one of these errors causes the PROsine to shut down attempt to restart the unit If the error occurs again call Xantrex Other messages describe problems you can troubleshoot Troubleshooting For details about Warning Error and Panel Fault messages see the Trou
4. PROsine 2 0 Inverter Charger Quick Reference Guide Configuration Menu Structure Overview xantrex when an error is active in the PROsine and the display panel in in Configure mode High AC Transfer V High AC Transfer Hz AC Series Mode Inverter Low V Shutdown Inverter Low V Warning Inverter Low V Restart Hysteresis Run Without Panel Inverter After Reset Without Panel Charger After Reset Without Panel Auto Restart After Error Reset to Defaults e Mode Settings Bulk Charge e Max Voltage e Max Current C e Threshold Voltage e Threshold Timeout e Mode Settings Absorption e Max Voltage e Max Current C e Max Timeout e Threshold Current C e Threshold Timeout Mode Settings Overcharge e Max Voltage e Max Current C e Max Timeout Mode Settings Float e Max Voltage e Max Current C e Max Timeout Threshold Voltage Threshold Timeout e Mode Settings Equalize e Max Voltage e Max Current C e Max Timeout e Threshold Change e Threshold Timeout e Mode Settings Constant e Voltage Setpoint e Current Setpoint Charger Mode Charger Type Charger High Battery V Warning Offset Clear Errors in PROsine Configure PROsine Basic Configure PROsine Advanced Configure Display Panel Configure Battery Diagnostics Clear Errors AC Breaker Size Load Sensing Audible Alarm Battery Size PS System Mode e Yes Load Sensing Load Sense Power LCD Backlight Mode Default Battery Temp View Last 20 PR
5. bleshooting section of the User s Manual If you need to contact Xantrex please record what is required in the Information About Your System section of the manual before calling This quick reference guide is intended as a job aid For complete details please consult your User s Manual PROsine Default Values Item Default Value Your Settings PROsine Default Values NOTE At a minimum configure the items marked with a after installation Adjustable From the Configure PROsine Basic Menu AC Breaker Size 15 amps p Adjustable From the Configure PROsine Advanced Menu Item Default Value Your Settings Mode Settings Overcharge e Max Voltage e 142V e Max Current C e 20 e Max Timeout e 0 Mode Settings Float e Max Voltage e 13 8V e Max Current C e 200 e Max Timeout e 2ldays e Threshold Voltage e 12 5V e Threshold Timeout e 15min Mode Settings Equalize e Max Voltage e 13 8V e Max Current C e 200 e Max Timeout e 0 e Threshold Voltage e 0 e Threshold Timeout e 0 Mode Settings Constant e Voltage Setpoint e 13 5V e Current Setpoint e 100A Charger Mode Standalone Charger Type 3 Step Charger High Battery V Warning Offset CHG 1 0V Hi V Warning Offset NOTE The values opposite the gray bar are set when you select a battery type If you did not subsequently change these settings