1. Figure 2 Front Panel LEDs Power This LED comes on when the switch is properly connected to power and turned on IP Reset Push Button Press the Front panel IP Reset push button to reset the Ethernet Switch back with the default User Login ID User Login Password IP Address Netmask and Gateway settings Port Status The RJ 45 ports are numbered from 1 to 16 on the 16 Port Switch The LEDs are located on the front panel of the switch displaying status for each respective port Please refer to the table below for more information Consult the following table for details b Before you use this table for troubleshooting make sure the switch is properly connected to powerand tumed on Express Ethernet Switch LB9017A R4 Physical Ports The 16 Ports Switch has sixteen 10 100Mbps ports using RJ 45 connectors and provides one slot for the optional single port fiber module The optional module allows fiber type multi mode single mode or WDM single mode fiber and connector SC ST MT RJ VF 45 or LC at user s discretion UNDERSTANDING FRONT PANEL DESIGN Power LED On Power feeding in Off Power switched off Improper connection Port LED On A valid network connection Flashing Transmitting or receiving data ACT stands for ACTIVITY Off Neither connection nor activity Speed On A valid 100Mbps connection Off A valid 10Mbps connection 1
2. Step 3 Carefully position the switch into the rack Step 4 Align the brackets to the side holes on the rack and use rack screws to secure the chassis with the rack Step 5 Proceed to the Connecting to Power section DESKTOP OR ANY FLAT SURFACE The switch can sit on desktop or any flat surface with adequate space and ventilation If you want to place it onto a shelf make sure the shelf can withstand the weight of the switch Step 1 Simply put the switch on the desired place Step 2 Ensure the switch receives good ventilation Step 3 Proceed to the Connecting to Power section 11 Express Ethernet Switch LB9017A R4 Optional Fiber Module Installation Consult the following illustrations before installation Step 1 Make sure the power is switched off The module is not hot swappable It may cause electric shock or any possible damage to the switch if the poweris not switched off Step 2 Remove the module from the static free container Step 3 Unscrew the cover plate of the expansion slot The slot for single port module is located at the right side of the Switch Step 4 Remove the plate Keep it for future use if you decide to remove this module later Step 5 Carefully slide the module into the slot following the internal plastic guide rails Step 6 Once it is fully slid in snap in the module to make a proper connection Step 7 Fasten the module screws Step 8 Finally t
3. or 10um 40km i The maximum node to node network distance is in full duplex operation ii MMF denotes Multi Mode Fiber SMF denotes Single Mode Fiber 30
4. Smart Ethernet Switch 17 3 x 8 2 x 1 74 in W440 x D207 x H44 mm 19 rack mount size 1U high Approximately 6 2 pounds 2 8kg 100 240 VAC 50 60 Hz 7 4W Maximum 0 45 C 32 113 F 10 70 14 158 F 10 90 non condensing FCC part 15 Class A CE Mark 28 Express Ethernet Switch LB9017A R4 Connector Pinouts Pin arrangement of RJ 45 connectors Figure 4 RJ 45 Connector and Cable Pins The following table lists the pinout of 10 100BaseT TX ports Connector Pin Out Pin Regular Ports Uplink port 1 Input Receive Data Output Transmit Data 2 Input Receive Data Output Transmit Data 3 Output Transmit Data Input Receive Data 4 NC NC 5 NC NC 6 Output Transmit Data Input Receive Data 7 NC NC 8 NC NC 29 Express Ethernet Switch LB9017A R4 Ordering Information 16 Fixed Ports Single Port Module Cable Cable 125um a Gilet Distance Speed Gegen Distance 100BaseTX 100m 100BaseFx MMF 2km 50 or 62 5um Cat 5 or better SC UTP STP 100BaseFX 2km um or 62 5um RJ 45 Sr 100BaseFx MMF 2km OR 50um or 62 5um MT RJ 100BaseFx MMF 2km 10BaseT 50 or 62 5um Cat 3 4 5 or EM ES eS better UTP STP ase 50um or 62 5um RJ 45 LC 100BaseFX SMF Up to 9um or 10um 120km SC 100BaseFX SMF Up to or 10um 20km ST 100BaseFX WDM SMF Up to
5. Tw Rx Trunking H 100M Ful On o 100M Ful On On QoS Mode Aw 104 Fa on Qos Priority fox um lt 1 100M F4 On Load Default SS mo 100m Fd Os Update Firmware J R IB 100M Ful On 100M Ful n 10M Fa On 100M Full On 100 On 100M Ful On o 100M Ful On o n n Auto 100M Ful 100M uto 100M No Choose Port No 01 17 e Auto Nway Choose Enable or Disable to enable or disable Auto Nway of the ports Speed Choose 100M or 10M speed for the ports Duplex Choose Full or Half Duplex for the ports Pause Choose Enable or Disable to enable or disable Pause for the ports e Choose Enable or Disable to enable or disable Backpressure for the ports 20 Express Ethernet Switch LB9017A R4 e Update Click the Update button and apply the new settings of the ports VLAN The VLAN parameters can be displayed by clicking the VLAN selection in the left sub menu Favo es Joos Qm x 2 O eg Ste 6 AB tete 182 19 1 10 Group VLAN Setting Configuration System Change IP Configuration Port VLAN Trunking Updwe LosdDetew QoS Mode QoS Priority Gro VLAN Member Load Default Update Firmware 1 The porte not chesced are the vian members Group No Click and choose the VLAN Group No 01 08 Me
6. change the factory default password e Update Click the Update button and apply the new System settings 18 Express Ethernet Switch LB9017A R4 IP CONFIGURATION The IP Configuration parameters can be displayed by clicking the IP Configuration selection in the left sub menu Favo es Tools Help Om O 9 fb 6 AE tete 192 14 1 10 IP Configuration Configuration System Change IP Configuration Port VLAN Trunking QoS Mode QoS Priority Load Default Update Firmware IP Address Netmask Default Gateway You can see and change the IP Address Netmask and Default Gateway of the Ethernet Switch Update Click the Update button and apply the new IP Configurations Please relogin the switch with the new IP Configuration after you click the update button 19 Express Ethernet Switch LB9017A R4 PORT The Port parameters can be displayed by clicking the Port selection in the left sub menu e SmartSwitch Web Base Controller Edt Yew Fees Tools Help Q x 2 fb Drun Jermes AE teo 92 60 1 10 Port Configuration Configuration Port No Auto Nway Speed Duplex Pause Back Pressure Enable 100M Ful Enable w Enable System Change L Update IP Configuration Port Current Status Setting Status VLAN i J Lek Speed Duplex Flow Nway Speed Duplex Pause Back Pressure
7. contents and report any apparent damage or missing items immediately to your authorized reseller Express Ethernet Switch LB9017A R4 Product Features 9 9 9 9 9 PROVIDES 16 10 100MBPS PORTS USING RJ 45 CONNECTORS AN OPTIONAL SINGLE PORT FIBER MODULE ALLOWS I00BASEFX MULTI MODE FIBER WITH SC ST MT RJ VF 45 OR LC CONNECTOR I00BASEFX SINGLE MODE FIBER WITH SC OR ST CONNECTOR I00BASEFX WDM SINGLE MODE FIBER WITH C CONNECTOR AUTO NEGOTIATION FOR SPEED AND DUPLEX MODE ON TX PORTS AUTO MDIX FOR ALL TX PORTS 4K MAC ADDRESSES 1 5M BITS BUFFER MEMORY STORE AND FORWARD MECHANISM TRUE NON BLOCKING ARCHITECTURE FULL WIRE SPEED FORWARDING RATE BROADCAST STORM FILTERING CONTROL BACK PRESSURE AND IEEE 802 3X COMPLIANT FLOW CONTROL SYSTEM IP CONFIGURATION PORT PORT BASED VLAN TRUNKING QOS MODE AND QOS PRIORITY SETTINGS THROUGH THE WEB BASED BROWSER PRESS THE FRONT PANEL IP RESET PUSH BUTTON TO RESET THE ETHERNET SWITCH BACK TO THE DEFAULT SYSTEM AND IP ADDRESS SETTINGS THE PORT VLAN TRUNKING QOS MODE AND QOS PRIORITY SETTINGS WILL REMAIN THE SAME AS WHEN THEY WERE LAST SAVED FRONT PANEL PORT AND POWER STATUS LEDS STANDARD 19 RACKMOUNT SIZE ONE UNIT IN HEIGHT Express Ethernet Switch LB9017A R4 Front Panel Display The LED indicators on the front panel provide you with instant feedback on each port status and help you monitor and troubleshoot the switch
8. 00FX Link On A valid network connection Port LED Off No connection ACT Flashing Transmitting or receiving data ACT stands for ACTIVITY Off Neither transmitting nor receiving data Express Ethernet Switch LB9017A R4 Installation Selecting a Site for the Equipment As with any electric device you should place the equipment where it will not be subjected to extreme temperatures humidity or electromagnetic interference Specifically the site you select should meet the following requirements The ambient temperature should be between 32 and 113 degrees Fahrenheit 0 to 45 degrees Celsius The relative humidity should be less than 90 percent non condensing Surrounding electrical devices should not exceed the electromagnetic field RFC standards for IEC 801 3 Level 2 3V M field strength Make sure that the equipment receives adequate ventilation Do not block the ventilation holes on each side of the switch or on the rear of the equipment The power outlet should be within 6 feet 1 8 meters of the switch 10 Express Ethernet Switch LB9017A R4 Installation and Placement Instructions MOUNTED TO 19 INCH STANDARD RACK Locate the accessories supplied in the product package Use the rackmount brackets and screws to install the switch into any EIA 19 standard rack Step 1 Attach the brackets to each side of the chassis Step 2 Apply the screws to each side and secure them tightly
9. W BLACK BOX NETWORK SERVICES October 2006 Express Ethernet Switch LB9017A R4 CUSTOMER Order toll free in the U S Call 877 877 BBOX outside U S call 724 746 5500 Free technical support 24 hours a day 7 days a week Call 724 746 5500 or fax SUPPORT 724 746 0746 INFORMATION Mailing address Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site www blackbox com E mail info blackbox com Express Ethernet Switch LB9017A R4 FCC Statement The FCC Federal Communications Commission restricts the amount of radio frequency emission and radiation coming from computer equipment The equipment introduced in this manual has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not instaled and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user is required to correct the interference at his her own expense Any changes or modifications not expressly approved by the manufacture would void the user s authority to operate the equipment Tradem
10. arks Product names mentioned in this manual may be trademarks or registered trademarks of those products All trademarks or brand names mentioned are properties of their respective companies Express Ethernet Switch LB9017A R4 Preface This manual describes how to install and use the 16 Ports Smart Ethernet Switch The TX ports of the switch introduced here auto negotiates the presence of 10 100Mbps and full half duplex mode and auto MDIX In addition it allows an optional 100BaseFX multi mode or single mode fiber module enabling long distance connection To get the most out of this manual you should have an understanding of networking concepts such as bridging IEEE 802 3 10BaseT Ethernet IEEE 802 31 100BaseTX FX Fast Ethernet and local area networks LANs For more information about these topics please refer to the Appendices In this manual you will find Introduction on the Switch Product features Illustrative LEDs functions Installation instructions Specifications Express Ethernet Switch Table of Contents LB9017A R4 FCC STATEMENT 2 TRADEMARKS 2 PREFACE 3 TABLE OF CONTENTS 4 PRODUCT OVERVIEW 6 FRONT VIEW itii mec oe eset tee ee ee d een 6 PACKAGE CONTENTS z 2 eise iets vet ex uu 6 PRODUCT FEATURES 2 1 1 1 Sia salsa 7 FRONT PANEL DISPLAY eto uma uma uuu ima sas 8 PHYSICAE PORTS u T N y SE y ym bed 9 Understandin
11. g Front Panel Design 9 INSTALLATION 10 SELECTING A SITE FOR THE EQUIPMENT 10 INSTALLATION AND PLACEMENT INSTRUCTIONS 11 Mounted to 19 inch standard rack 11 Desktop or any flat surface 11 OPTIONAL FIBER MODULE INSTALLATION 12 2 ua n eic 13 CONNECTING TO YOUR NETWORK 13 Cabling 13 Network Segmentation 14 SWITCH CONFIGURATION 15 SETTING UP WEB BASED BROWSER INTERFACE 15 LOGGING ON TO THE ETHERNET SWITCH 15 Switch IP Address 15 ID 16 Password 16 MAIN MENU tole haah tbe cote Peut cbe qapin 17 System Change 18 IP Configuration 19 Port 20 Express Ethernet Switch LB9017A R4 VLAN Trunking QoS Mode QoS Priority Load Default Firmware Update TECHNICAL SPECIFICATIONS PHYSICAL SPECIFICATIONS CONNECTOR PINOUTS ORDERING INFORMATION 28 29 30 Express Ethernet Switch LB9017A R4 Product Overview SIE Y X3 ae rS 2221 A Figure 1 16 Ports Smart Ethernet Switch Package Contents When you unpack the product package you shall find these items listed below Y The 16 Ports Switch Y One AC power cord vi User s Manual Please inspect the
12. ick and choose Port Base VLAN Tag and or DS for Port No 1 17 e Update Click the Update button and apply the new settings of the QoS Priority 24 Express Ethernet Switch LB9017A R4 LOAD DEFAULT The Load Default parameters can be displayed by clicking the Load Default selection in the left sub menu SmartSwitch Web Base Controller Microsoft Internet Explorer Em yew Favertes Toots O x 2 fb Wua O 1 2 Sites 12 1 10 Load Default Setting Losa Configuration System Change IP Configuration Port VLAN Trunking QoS Mode QoS Priority Load Default Update Firmware 2 e Click the Load button to load the default settings Once the Load button is selected all last saved Port VLAN Trunking QoS Mode and QoS Priority settings will be reverted back to the default settings 25 Express Ethernet Switch LB9017A R4 FIRMWARE UPDATE The Firmware Update parameters can be displayed by clicking the Firmware Update selection in the left sub menu F SmartSwitch Web Base Controller Microsoft Internet Explorer ew Faves Toots Help O O x 2 sm 6 AB 162 1 10 Configuration System Change IP Configuration Port VLAN Trunking QoS Mode QoS Priority Load Default Update Firmware EIE Firmware Update Before updating the you should instal the TFTP P web manageme
13. mber Port Click and choose the Member Port 01 17 to be added into the VLAN Group No 01 08 Comment Type Comment for VLAN Group No 01 08 Update Click the Update button and apply the new settings of the VLAN groups Load Default Click the Load Default button and load the default settings of the VLAN groups 21 Express Ethernet Switch LB9017A R4 TRUNKING The Trunking parameters can be displayed by clicking the Trunking selection in the left sub menu SmartSwitch Web Base Controller Fle Edt yew Faves Tools Qm x 2 49 sa prrs QI 6 Sites 12 1 10 Trunk Configuration Configuration Trunk Hash Algorithm Selection SPortiD OSA ODA OSA amp DA System Change Pot Pon Fon IP Configuration n Port 5 Pomp Pon Port Trunk VLAN o t n n Trunking QoS Mode QoS Priority Load Default Update Firmware e Trunk Hash Algorithm Selection Click and choose Port ID SA DA or SA amp DA Trunk Hash Algorithm e TrunkO Click and choose Port1 Port4 to be added into the Trunko Trunkl Click and choose Port5 Port8 to be added into the Trunk1 Update Click the Update button and apply the new settings of the Trunking Groups 22 Express Ethernet Switch LB9017A R4 QOS MODE The QoS Mode parameters can be displayed by clicking the QoS Mode selection in the left sub menu SmartSwitch Web Base Controller Ed
14. rt Cable Max Standards Speed Half Full Distance Duplex 10BaseT RJ 45 10 20 Cat3 40r5 100m Mbps UTP STP 100BaseTX RJ 45 100 200 Cat 5 100m Mbps UTP STP 100BaseFX ST SC 100 200 62 5 125um Up to i Mbps multi mode 2km Multi mode MT RJ VF p 45 LC fiber 100BaseFX 100 200 10 125um Up to Mbps single mode 120km fiber Single mode 100BaseFX WDM Single mode 100BaseFX ST 100 200 10 125um Up to Single mode Mbps single mode 20km fiber 100 200 10 125um Up to Mbps single mode 40km fiber 14 Express Ethernet Switch LB9017A R4 Switch Configuration Setting up Web Based Browser Interface The Ethernet Switch provides a browser interface that lets you configure and manage the Ethernet Switch from a Web browser such as Microsoft Internet Explorer or Netscape Navigator remotely By connecting to any port of this Ethernet Switch you can access the Ethernet Switch s web interface applications directly in your web browser by entering the default IP address of the Ethernet Switch 192 168 1 10 You can then use your web browser to list and manage the Ethernet Switch configuration parameters from one central location Logging on to The Ethernet Switch SWITCH IP ADDRESS In your web browser specify the default IP address of the Ethernet Switch 192 168 1 10 Express Ethernet Switch LB9017A R4 Edt Yew Favertes Tools Om O 9 AD 2 O Sites 10 1 10 Enter the facto
15. ry default User Login ID admin PASSWORD Enter the factory default password no password press lt Enter gt directly Otherwise enter a user defined password if you follow the instructions later and change the factory default password 16 SmartSwitch Web Base Controller Express Ethernet Switch LB9017A R4 Microsoft Internot Explorer Edt Yew Favertes Tools seva renger QM res 6 Q x i2 SmartSwitch Web Base Controller 1921681 10 admir Microsoft Internet Explorer Edt Yew Favertes Tools Heb Q o NAG o rores 6 Configuration System Change IP Configuration Port VLAN Trunking QoS Mode QoS Priority Load Default Update Firmware Switch Configuration O remm 17 Express Ethernet Switch LB9017A R4 SYSTEM CHANGE The System Change parameters can be displayed by clicking the System Change selection in the left sub menu Fle Ep yew Fuertes Tos Heb 9 2 sm 6 Sites 10 1 10 System Change Configuration System Change Switch Nome New Password IP Configuration Port Version 2 OOVE VLAN Address 00 05 10 00 00 02 Trunking QoS Mode Update QoS Priority Load Default Update Firmware e Switch Name Type a switch name for this Ethernet Switch e New Password Enter a user defined password and
16. st station Once completing the sofware installation and configuring the DHCP program n in the document you chek the update button The firmware will be update You d better carefully read the document regarding the update procedure preventing the unexpected problem form occurring Update e Click the Firmware Update button to update firmware to the switch The TFTP protocol is used to upload firmware to the switch You should install the TFTP amp DHCP server on your PC Web management station before updating the firmware 26 Express Ethernet Switch LB9017A R4 Technical Specifications Applicable Standards Fixed Ports Optional 1 port Module Type Speed Switching Method Performance Chassis LED Indicators 16 Ports Web based Smart Ethernet Switch IEEE 802 3 10BaseT IEEE 802 3u 100BaseTX FX Sixteen ports for the 16 Port Switch 100BaseFX multi mode or single mode module 100BaseTX FX 200Mbps for full duplex 100Mbps for half duplex 10BaseT 20Mbps for full duplex 10Mbps for half duplex Store and Forward 148 810pps forwarding rate per port for 100Mbps 14 881pps forwarding rate per port for 10Mbps Power TX port Link ACT SPEED 2 LEDs FX port Link ACT 1 LED 27 Express Ethernet Switch LB9017A R4 Physical Specifications Dimensions Weight Power Input Power Dissipation Operating Temperature Storage Temperature Humidity Emissions 16 Ports Web based
17. t ew Favores Tools Q x 2 Dren 6 AE 162 1 10 Priority Mode Configuration Pronty Mode System Change IP Configuration obin Low weight 0 w High weight Port Update VLAN When the queue weight is set to 0 it will be treated as 8 Trunking QoS Mode QoS Priority Load Default Update Firmware e Click and choose First In First Service All High before Low or Weight Round Robin Priority Mode The Priority Mode will be treated as 8 when both Low weight and High weight of Weight Round Robin are set to 0 e Update Click the Update button and apply the new settings of the QoS Mode 23 Express Ethernet Switch LB9017A R4 QOS PRIORITY The QoS Priority parameters can be displayed by clicking the QoS Priority selection in the left sub menu SmartSwitch Web fase Controller Micr EM Ep yem Foes Too Heb O X f5 s frre 6 AB tete 1j192 162 1 10 Class of Service Configuration Configuration F Ecable High Priority Port No Mode Pon VLAN m ps Pot VLAN System Change Bare Tag Base Tag IP Configuration 1 o D D 0 D Port VLAN Trunking QoS Mode QoS Priority Load Default Update Firmware Update CE As long as any of three COS schemes 802 1Q VLAN Tag IP TOS DS or Port Base is mapped to high the data packet will be treated ar the bagh priority 9 e Cl
18. urn on the power Figure 3 Removal of cover plate Fiber module being installed 12 Express Ethernet Switch LB9017A R4 Connecting to Power Locate the supplied AC power cord Step 1 Step 2 Step 3 Connect the AC power cord to the receptacle at the back of the switch Attach the plug into a standard AC outlet with a voltage range from 100 240VAC The power LED on the front panel will then illuminate Connecting to Your Network CABLING Step 1 First ensure the power of the switch and end devices is turned off b It may cause an electric shock or any possible harm to you if the power is not switched off Step 2 Step 3 Step 4 Prepare cable with corresponding connectors for each type of port in use Consult the table below for cabling requirements based on connectors and speed considerations Connect one end of the cable to the switch and the other end to a desired device Once the connections between two end devices are made successfully turn on the power and the switch is operational Express Ethernet Switch LB9017A R4 NETWORK SEGMENTATION The maximum segment distance between a node and a directly connected switch port on a 100BaseFX network is 120km using 10 125 or 9 125 um single mode fiber optic cable It is capable of a maximum span of 2km when 62 5 125 or 50 125 um multi mode fiber optic cable is used Cable Specifications Table Ethernet Connector Po
Download Pdf Manuals
Related Search
Related Contents
Rollertec RTS User Manual FR_V3 大会要項をダウンロード - 静岡県バスケットボール協会 halsey taylor owners manual manual del propietario halsey taylor Panasonic MX-AC300 food processor User Manual - RONDA Industrial Vacuum Cleaners PHICOMM X100 16GB Black smartphone UM10699 User manual for SPI User Guide 主な韓国語通訳/翻訳実績表 1999 年∼2008 年 L`évolution des normçs de scienfificité Copyright © All rights reserved.