Installation of the Limit Switch

image

Contents

1. 4 Read and understand the factory manual 5 Always wear ANSI approved goggles when working with tools and equipment Don t remove this warning label Made in China e The factory declines all responsibility with respect to the automation safety and correct operation when other supplier s components are used e Only use original parts for any maintenance or repair operation e Do not modify the automation components unless explicitly authorized by the factory e Instruct the product user about the control systems provided and the manual opening operation in case of emergency 2 e Do not allow persons or children to remain in the automation operation area e Keep radio control or other control devices out of children s reach in order to avoid unintentional automation activation e The user must avoid any attempt to carry out work or repair on the automation system and always request the assistance of qualified personnel e Anything which is not expressly provided for in the present instructions is not allowed e Before installing the gate opener check that all moving part as well as the sliding gate is in good mechanical condition correctly balanced and opens and closes properly e Save these instructions for future use Preparation for Installation Before proceeding to your operator installation check if your gate structure is in accordance with the current standards especially as follows The gate sliding trac
2. Positive Stop in fully opening position Parts List a a Remote Control Moving Gate Can Cause Injury Or Death 1 Keep Clear Gate may move at any time Don t remove this warning label Made in China Release Key Gate Operator 1 pc 8 Lock Washer 8 pcs hee hal Light Duty Magnet Assembly M8x20 Bolt Plastic Rack Reinforced with Steel N pole amp S pole 4 pcs 1005mmxN pcs Optional Optional Accessories Parts List Optional 250 PCS Max Back up battery 1 set LM125 External Receiver 2 5 Video Intercom 7 Video Intercom a 1 pc LM138 1 set LM162 1 set LM165 Back up battery box 1 pc Alarm Lamp 1 pc Photocell Beam System Wall push button LM130 LM140 1 set LM102 1 pc LM147 Solar Controller 1 pc Solar panel 1 pc Supporting frame for solar Bracket for solar panel LM117 LM118 LM109 panel 1 pc LM115 1 pc LM116 Mounting post for keypad 1 pc LM107 Keypad wireless Wired Keypad 1 pc LM106 24 Loop Detector 1 pc LM105 ID card LM170 1 pc LM155 Technical Specifications amp Features Specifications Power supply 120V 60HZ or 230V 50HZ Motor 24VDC Absorbed power 120W Gate moving speed 7 second 18 cm second Max gate weight 900LBS Max torque 8Nm Environmental conditions from 15 C to 40 C Protection class IP44 REV 13a Dimensions 29 5x20x22 5 CM Features Soft
3. installing the operator and limit switch The process is as follows 1 Take of the rubber stopple 2 Insert the Release Key provided and turn it in counter clockwise 90 to disengage the clutch between the gear shaft and power output Now the operator is in the manual operation Fit the plastic rack reinforced with steel 1 Start with gate in closed position 2 There are four sections of plastic rack which is one meter length each section for standard package you can order extra rack from dealer if necessary 2 Put one end of rack section on the gear of operator as a temporary support Make rack level and mark the rack s mounting holes on the gate 3 Fit the rack by self threading screws This kind of plastic rack is quieter and allows height adjustments to be made even after it has been fixed Please keep 1 0mm space between the rack and the gear to avoid the weight of the gate leaf effect on the operator Hex Bolt M870 4 pcs Plain Washer 8 4 pcs 10 15mm Magnet Component Spring Wahser 8 4 pcs TT N pole amp S pole Hex Nut M8 4 pcs HI Magnet Bracket 2 pcs Limit Switch Plastic rack reinforced with steel Self threading Screw DS 223 4 P amp aConerete Pad 3 0 Pa 382 amp Plate PLA ai Pe A Pe ee Important Check that the rack teeth must engage the gear teeth throughout their full thickness If not adjust the position of the operator or and place a few shims between
4. and etc to operate the gate operator to run for a complete opening cycle and a complete closing cycle You would achieve the soft stop in your next opening closing cycle Factory default soft stop time is 1 Seconds You can turn the DIP switches on off to fine adjust the soft stop time to meet your actual needs DIP eo BATEL 1234567 8 The soft stop period of the motor is 0 5 1 1 5 seconds 12 DIP Switch 6 7 Auto close time of the gate operator DIP Switch 6 ON 30 Seconds OFF 0 DIP Switch 7 ON 60 Seconds OFF 0 NOTE The auto close function would be disabled if both DIP switches are turned to off factory default setting OFF Left open For gate to open toward left and close toward right ON Right open factory default setting For gate to open toward right and close toward left 2 Potentiometers Potentiometer A and B are used to adjust the stall force of the gate operator One for opening force and another for closing force Turn the potentiometer clockwise to increase the stall force Turn the potentiometer counter clockwise to decrease the stall force 2 lt CW force CN CCW force qn aE 0 mis 085 J i a S j Te i m S Control Board maaala FTT mm m fomm el lf a LAMP BAT SOLAR m segssce MOT FO 24 FC 6 Test the reversing sensitivity For the
5. erase the remote c cece ee ccce cece cece cece eeeeeneeeeeseeessaeeeeseeeessaneeeeganenesgeeeeas 14 How to use the remote to control the operator cece cece ec ee ee eee eeeeeeaee sees eseeeesaeessanessaneesaees 14 Alig Ul a 6 9 gle Eeenereenner nee meer a Netmr neon eo nae erent tenet centr tee ae een ee ee een 14 NL AUTON VANCE srs a oa aeterd da aula nde aba cranks Wlapelamisiia aati r er Cuenca eke 15 Thank you for purchasing AR900 sliding gate operator We are sure that the products will be greatly satisfying as soon as you start to use it The product is supplied with a user s manual which encloses installation and safety precautions These should be read carefully before installation and operation as they provide important information about safety installation operation and maintenance This product complies with the recognized technical standards and safety regulations General Safety A WARNING An incorrect installation or improper use of the product can cause damage to persons animals or properties e Scrap packing materials plastic cardboard polystyrene etc according to the provisions set out by current standards Keep nylon or polystyrene bags out of children s reach e This product was exclusively designed and manufactured for the use specified in the present documentation Any other use not specified in this documentation could damage the product and be dangerous e The factory decl
6. remote to control the opener Key A is used to operate the operator to work alternately open stop close stop open When the Midway Mode function is enabled Key B is used to achieve the Midway Mode function open the gate for the pre setting time When the Midway Mode function is disabled the operator works alternately open stop close stop open by pressing Key B Troubleshooting Have a multi meter to check voltage and continuity Use caution when checking high voltage terminals Possible Solution s The remote control does not emit any Check if the batteries are exhausted replace them if necessary single The opener doesn t 1 Make sure that the power cord is properly plugged into the mains outlet run Power LED is 2 Check the fuse is blown in the control board if necessary identify the OFF reason for the failure and then replace a new one Make sure the photocell beam is not blocked if the photocell is used Check the terminal 16 should be shorted with terminal 17 by a jumper wire Please reset this jumper wire if it is loss The opener doesn t run Power LED is ON 1 The selected force is too small to move the gate Turn the Potentiometer clock wise to increase the force 2 Disconnect the gate from the gate operator and check that the gate slides freely without any binding The gate starts but it is immediately stop or reverse REV 12a Maintenance Every six months check the following items for p
7. sake of safety it is very important to test the reversing sensitivity as soon as the control board set is finished The reversing sensitivity adjustment is inverse correlation with stall force adjustment in potentiometer A and B In other word the stall force level is higher the reversing sensitivity level is lower Put an immobile object along the gate path and then operate the gate to strike it during the open and close cycles The gate must reverse as soon as object is struck with it If the gate doesnt reverse please increase the reversing sensitivity by turning the potentiometer in counter clockwise direction Turning the stall force potentiometer toward to MIN position to increase the reversing sensitivity Note 1 If the sensitivity setting is too higher the gate will stop or reverses very easy by itself while there is little obstruction or resistance such as strong wind or heavy snow sometimes Note 2 Always check the gate reversing function every each time of control board set or restart after power off 13 How to learn or erase the remote Learn the remote Press and release the learn button the REM LED light will be on then press the key in the remote twice in 2 seconds the REM LED light will flash for 4 seconds Now the remote has been learnt successfully Erase all the remote codes REM LED Press and hold the learn button until the REM LED light is off Now all remote codes have been erased REMOTE How to use the
8. start and soft stop Midway mode Easy to install and low maintain Quick selection for the gate open close direction Reliable rolling code technology Emergency release key in case of power failure Stop Reverse in case of obstruction during gate opening closing Built in adjustable auto close 0 30 60 90 seconds Built in max 90 seconds Motor running time MRT for multiple safety protection Reliable electromagnetism limit for easy adjustment Optional accessories Installation Overview Solar Panel nie Alarm Lamp Magnet N pole Gate Opener Rack Magnet S pole Photocell Wall Push Button 24V Battery Installation of the Operator Caution Be sure that the operator is installed in a level and paralleled position and is properly secured Improper installation could result in property damage severe injury and or death 6 Before starting installation ensure that there is no point of friction during the entire movement of the gate and there is no danger of derailment Ensure that the Warning Signs are present Necessary Tools The following tools may be necessary to install the Gate operator You will need screwdrivers an electric drill wire cutters and a wire stripper a socket set and possibly access to a welder When install the operator you should build a concrete pad to support the base plate of operator in order to maintain proper stability The installation proceeds are
9. the rack and gate 4 Manually slide the gate leaf to ensure the rack is proper on the gear of operator 5 Repeat same steps of first rack section to install the rest rack sections until proper length is reached i 6 Cut away any excess of the rack Note rack length must be longer than actual travel of the gate 7 Thoroughly fasten the four nuts as well as spring washers onto expansion bolts tightly enabling the operator is firmly secured on the concrete pad during the whole gate travel Installation of the Limit Switch Before install limit switch make sure the gate operator is put in manual operation the clutch connected with gear shaft is disengaged and the mains power supply is disconnected Position the two Magnet Components approximately on the gate and move the gate by hand to fix them in place Fit magnets bracket Push the gate fully closed by hand Locate and install the magnet bracket so that the operator will stop at the desired close position when the close limit switch approaches it Push the gate fully open by hand Locate and install the magnet bracket so that the operator will stop at the desired open position when the open limit switch approaches it The magnet component with N pole outside must be installed at left side and the magnet component with S pole outside must be installed at right side from the view inside of property Finally adjust the magnet to the proper position by moving the gate with the motor The m
10. ALEKO AR 900 Please read and follow all warnings precautions and instructions before installation and use Periodic checks of the operator are required to ensure safe operation For residential use only Save this manual CE EMC www WholesaleGateOpener com REV 13a Table of Contents General Sale oreo ttars hetero teed ne cacie eee eign eaten altel Dale een leed ee ee rete tet 2 Preparation Tor IMStaWallON cererea ae e E EE nad Ma seanghendacuad 3 PANS EISE anre T E E E E 4 Optional Accessonres Fanm MISE sinen E E E nee aeteiea 5 Technical Specifications amp F ature canna a E a eee SEE EEE ea E Eda E EEE EEE EEEES 5 Motalan OVEMICW canals acetic cnt aut cbuaacdiaswisnddademsdnaasecni Saeed Gena I E 6 Installation Or the Operator gcc tei e tere ate eesics chee det ahead tug E E E A A auaieacatndaante 6 Manual ODGrauon cn ccreadvscnnncaenvaniddoabirudauleualtdanebutoeaueGullndadiheeuthusdn ceded ualin dered E E ETE 7 Fit the plastic rack reinforced with Steel cc cece cece ccc e cece eee e eee eeaceeseeeeeeseeegeeeeaeeegeeegneeeaeeeanens 8 Installation Or The MIT SWINGIN seat wade pet a a a a teedatee tsi cd Ss hen cansaiensasenentatal 9 Connecting Ol POWEr 2S5UDDIV lt at2csemassesnteteaietocts a coe a ame teetideded 10 Connecting ofthe Control Board seseina re e ET lets 10 SEUNG Ol ThesGONnWOl BOAKG crearse ara a 12 Test ING reversing SCNSIIVILY yesin a E E me ueareumameet 13 How to learn or
11. HITE wire of the wired keypad should be connected into the 15 terminal 8 Photocell Use a 2 core cable to connect the terminal of the photocell s emitter to the 12 terminal the terminal to the 13 terminal Also the and terminals of the photocell s receiver should be connected to the 12 and 13 terminals in parallel Use another 2 core cable to connect the COM terminal of the receiver to the 16 terminal the NC terminal to the 17 terminal 1 Ge Ge Ge Ge Ge Ge Ge Ge Ge Ge Ge Je Ge de Je Ge Ge Je gt Se Je Ge Se gt Ge Se De Ge Ge Ge Ge Ge Ge E S TIPS x The terminal 16 and 17 on control board should be shorted 1f the V photocell beam system optional does not use A wire jumper has been used for short to terminal 16 and 17 in factory Please check if this wire jumper is missing or keep the photocell in alignment when the gate can open but fails to close BH D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D 0 0 9 Loop Detector First insert the LOOP DETECTOR BOARD into the CONTROL BOARD and then connect the twisted pair to the 18 and 19 terminals A 9 d d 9 D D 11 REV 12a 10 Solar Panel Please refer to the manual instruction of solar panel and controller separated Setting Of the Control Board WARNING Cut off the power before change the settings Keep a
12. agnet should be 39 59 away from the magnetic limit switch If it is too far away the switch will fail to work The distance between the magnet and the opener should be 1 2 12mm with the opener cover on Adjust the position of the magnet until the positions of the opening and closing meet the requirement REV 12a Connecting Of Power Supply BV oe S Ni A f A The power supply cord should not be smaller than HO5R1V F 30 75mm 18AWG for its diameter Connect the live wire neutral wire and earth wire to the L N and PE terminal respectively A if A QR Wem AVE 3 EEG W mi AG a Q ar NN F Connecting Of the Control Board Control Board T tscn8 Nima f KES lapl joe se e GGOGGUOO mmm oe om lo ole el 240UT OSC PHOTO XB1XB2 RED GREEN E Reserved Hall Signal Loop Detector LM154 Photocell LM102 Receiver Emitter YELLOW Limit Switches f E 12 Alarm Lamp LM140 13 13 15 ee Output 24VDC bs S 14 LATE e S 24V BLACK 14 On J Wired Keypad Battery LM125 External Receiver LM138 Push Button LM145 LM106 24 10 1 Motor The RED wire of the motor should be connected into the 1 terminal The GREEN wire of the motor should be connected into the 2 terminal 2 Limit Switches The RED wire of the limit switches should be connected into the 3 terminal The BLACK wire of the limit switches should be connected into
13. as follows 1 Dig a hole for a concrete pad which should be approximately 50 x 32 x Hex Bolt M8x20 4 pcs 35cm 20 x 13 x 14 It may Spring Washer 8 4 pcs protrude 10 cm 4 above ground and _ Plain Washer 8 4 pcs 25 cm 10 in depth underground Increase the pad height if necessary to protect the system from flooding heavy snow etc Expansion Bolt 4 pcs 2 Prepare one or more conduits for the NN electrical cables before pour concrete Base Plate 1 pc Remember that cable conduits have to pass through the hole in the base plate Cable 3 Pour concrete and before it starts to harden check that it is parallel to the gate leaf and perfectly level Red Ob oe 4 Mark the position of four expansion ee Conduit a zi anchors according to the position of os5si ia isens mounting hole on the base plate as soon as concrete become harden Double check your marking move the base plate and drill the 4 holes using a 10mm 3 8 masonry bit Put the 4 expansion anchors provided into the holes and firmly tighten 5 Place the opener onto base plate Check that it is perfectly parallel to the gate leaf and then screw the four bolts and washers supplied It s only temporary installation Further adjustment will be required when install the rack Gate Operator 0 100 mm rea 8mm Sa Manual Operation The operator should be put in the manual emergency release position before fitting the rack
14. ines all responsibility for any consequences resulting from improper use of the product or use which is different from that expected and specified in the present documentation e Do not install the product in explosive atmosphere e The factory declines all responsibility for any consequences resulting from failure to observe Good Technical Practice when constructing closing structures door gates etc as well as from any deformation which might occur during use e Disconnect the electrical power supply before carrying out any work on the installation Also disconnect any buffer batteries if fitted e Fit an omnipolar or magnetothermal switch on the mains power supply having a contact opening distance equal to or greater than 3 5 mm e Make sure a residual current circuit breaker with a 30mA threshold is fitted before the power supply mains e Check that earthing is carried out correctly connect all metal parts for closure doors gates etc and all system components provided with an earth terminal e Fit all the safety devices photocells electric edges etc which are needed to protect the area from any danger caused by squashing conveying and shearing e Position at least one visible indication device Alarm lamp and fix a Warning sign to the structure Moving Gate Can Cause Injury Or Death 1 Keep Clear Gate may move at any time 2 Do not allow children to operate gate or play in gate area 3 This gate is for vehicles only
15. k is linear and horizontal and the wheels are suitable the gate should be mounted and moving freely Check that the structure is sufficiently strong and rigid and that its dimensions and weights conform to those listed in the specifications table of this document Make sure that the gate is plumb and level The fence posts must be mounted in concrete The gate does not bind or drag on the ground e The gate manual operation can be carried out smoothly along its entire run and there is no excessive side slipping e The opening and closing gate stops are positioned A WARNING Remember that control devices are intended to facilitate gate operation but can not solve problems due to any defects or deficiency resulting from failure to carry out correct installation or maintenance Take the product out of its packing and inspect it for damage Should it be damaged contact your dealer Remember to dispose of its components cardboard polystyrene nylon etc according to the current prescriptions Refer to the following Figures for gate installation Using the post or wall as a stop either directly or indirectly is not recommended so as to protect the post or wall against damaging shock from the sliding gate Vertical View Positive Stop in fully closed position It is suggestion that there is a 4 10cm distance at least between lt Aminin the gate edge and the gate wall when the gate is fully open ee a A Le
16. roper operation of the unit Lubricate shafts Keep operator clean at all times Check for loose or corroded wire Ensure the operator is well earthed and correctly terminated Always check the Stop Reverse in case of obstruction function when performing any maintenance If this function can t be made operable remove this operator from service until the cause of the malfunction is identified and corrected According to Waste of Electrical and Electronic Equipment WEEE directive WEEE should be separately collected and treated If at any time in future you need to dispose of this product please do NOT dispose of this product with household waste Please send this product to WEEE collecting points where available www WholesaleGateOpener com 7106 S 220th St Kent WA 98032 USA sales WholesaleGateOpener com 2012 2014 ALEKO All Rights Reserved 15
17. the 4 terminal The YELLOW wire of the limit switches should be connected into the 5 terminal 3 Alarm Lamp 24VDC The RED wire of the alarm lamp should be connected into the 6 terminal The WHITE wire of the alarm lamp should be connected into the 7 terminal 4 Battery The positive terminal of the battery should be wired to the 8 terminal The negative terminal of the battery should be wired to the 9 terminal Recommend strongly to use the controller LM118 WA4004 to connect Battery with battery s Terminal of control board if the battery is used as the primary power supply in system such as SOL PLUS KIT Please refer to the user manual of control LM118 WA4004 separately 5 External Receiver The RED wire of the external receiver should be connected into the 12 terminal The BLACK wire of the external receiver should be connected into the 13 terminal The BROWN wire of the external receiver should be connected into the 14 terminal 6 Push Button The push button should be wired to the 14 and 15 terminals The gate operator works alternately by pushing the button open stop close stop open 7 Wired Keypad 24VDC The RED wire of the wired keypad should be connected into the 12 terminal The BLACK wire of the wired keypad should be connected into the 13 terminal The BLUE wire of the wired keypad should be connected into the 14 terminal The W
18. way from the gate during you set the gate opener system in case of the unexpected gate moving Always ask the help of professional technician electrician if you have any question 1 DIP Switches The DIP switches are used to set the running time of the motor in pedestrian mode fine adjust the soft stop period of the motor auto close time of the gate opener and fast change the open close direction which is determined by the position of the gate opener installed Je Be ON DIP ot gl owe r P i CW force NA SSccw WESTER wi ON Control Board a py f i a m ALS 2 R k Ti AP Tna eA ole fo G eOoqogcgq gd jgsgss s seses mn om a a a ol a MOT FO 24 FC LAMP BAT SOLAR BAT SOLAR DIP Switch 1 2 Running time of the motor in Midway Mode DIP Switch 1 ON 2 Seconds OFF 0 DIP Switch 2 ON 4 Seconds OFF 0 NOTE The midway mode function would be disabled if both DIP switches are turned off Factory default setting is disabled DIP E g a E d d J H i Running time of the opener in midway mode is 2 4 6 seconds 12345678 DIP Switch 3 5 Fine adjust the soft stop period of the motor DIP Switch 3 ON 0 5 Second OFF 0 DIP Switch 4 ON 1 Seconds OFF 0 DIP Switch 5 ON 2 Seconds OFF 0 NOTE Every time you restart the gate opener after power off you should use the access control device such as remote push button