Home

Mole

image

Contents

1. removed from service immediately Lot no Batch no A 3 E 7 7 A Production year Running number ih Visual inspection Check the product Stability test I Ensure that the materials seams stitching KG Try to bend the product verify that it feels firm handles buckles are intact faultless stable and solid Mechanical load or stress Test handles Test low high friction Draw hard in the handles in opposite directions 3 Place the product on a firm surface or a bed and control the material seams and stitching place your hands on the material and test the Test buckles friction by pushing your hands down into the Lock the buckle and draw in opposite directions product control the buckle and the stitching Low friction slides effortlessly High friction no sliding moving Check always Manual transfer aids with handles straps and buckles Manual transfer aids for sitting and lying transfer Manual transfer aids with high or low friction The product can be AT scrapped in accordance with national regulations Read the User Manual If in doubt please contact Etac Customer Service or local distributor for more information and guidance For more information about training and the use of these products contact the Etac transfer experts www etac com Class 1 European Council Directive MDD 93 42 EEC on medical devices Manufacture Etac Immedia A S Egeskowej 12 DK 8700 Horsens Denmark etac im
2. Mole inmedia Instruction for Use a part of Etac IMM1019 IFU GB Version 5 2015 Contents Enn Page General Symbols Intended use Intended enviroment ooooooooo 4 Practical handli ga mein aa a hte Hei te api 5 Notice Materials Cleaning oooooooooWoWooWoWooWooWoW Wo maan 6 Articles Combinations ee uei dette ea NA na 7 Service Information asd d EE et rm Lee cte sde fos s dut Ee Eb ee 8 General Thank you for choosing an Etac product To avoid accidents and injury when moving and handling the products read the manual carefully The person described as the user in this user manual is the person who is lying or sitting on the product The assistant or assistants are the people who manoeuvre the product This symbol appears alongside the text in the manual It draws the reader s attention to points at which there may be a risk to the health and safety of the user or assistant The products comply with the standards applicable for Class 1 products in the European Council Directive MDD 93 42 EEC on medical devices Lot no Batch no x x x x x x x x x x Production year Running number At Etac we strive to improve our products all the time and therefore we reserve the right to make changes to products without prior warning All measurements given on illustrations and similar material are for guidance only and Etac cannot be held liable for errors and defects The information given in th
3. an be tumble dried The glide bags can also be wiped with disinfectant Do not use fabric softener Never try to repair a product yourself Close Velcro handles before washing Never use a defective product Articles Article no Description Size mm IM407 Mole x ray glide board W800 x L400 IM4017 Glide bag 560 mm opening W560 x L470 Service Information Thank you for choosing an Etac product If the customer makes adjustments repairs or combinations not predetermined by Etac the Etac CE certification and Etac warranty will be voided Warranty Two year warranty on material and manufacturing defects provided that the product is used correctly Before taking a product in service always make a risk assesment according to national and or local legislation First inspection e Is the packaging intact e Read the label on the packaging and check the article no and product description e Check that Short Instruction is enclosed updated User Manual Instruction for use can be downloaded from www etac com or contact your Etac Customer Service or the local distributor e Check the label on the product does it include article no product description lot batch no cleaning instructions and supplier name Periodic Inspection e Make sure that your Manual transfer system always is in a perfect condition After wash always check materials stitching handles buckles e Ifthe product shows signs of wear and tear it must be
4. der to hip The Mole can be used without a draw sheet in which case it is positioned under the sheet Notice Special features Always check the product before use and after washing There is a risk that the user may slide off Never leave the user alone on the edge of the bed Never use a defective product If the product shows signs of wear and tear it must be scrapped Never leave the product on the floor Read these instructions carefully It is important that assistants receive instruction in manual Always make a risk assessment and secure that the handling Etac offers advice and training for assistants For assistive product can be used at the individual user further information contact Etac and in combination with other devices that it is safe for the user and caregivers Always use the correct manual handling techniques Encourage the client to assist where possible If in any doubt please contact Etac To ensure that the client feels safe and that every manual handling is smooth always plan the manual handling in advance Materials The Mole x ray glide board is produced in synthetic materials The glide bags and cover are 100 nylon Cleaning The product should be checked regularly preferably each Washing instructions time it is used The Mole can be wiped with disinfectant or washed down with soapy water The glide bags are machine Check that seams fabric and hinges are not damaged washable at 80 C and c
5. is manual including re commendations combinations and sizing does not apply to special orders and modifications If the customer makes adjustments repairs or combinations not predetermined by Etac the Etac CE certification and Etac warranty will be voided If in doubt please contact Etac Warranty Two year warranty on material and manufactu ring defects provided that the product is used correctly For further information on the Etac transfer range see www etac com The product can be scrapped in accordance with national regulations Symbols Washing Iron Handwash Do not dryclean Wipe off Do not bleach Tumbledry Risk of sliding down Keep out of the sun Never leave on the floor User mass limit maximum rated load Warning The product can be scrapped in accordance with national regulations Read the User Manual Manufacturer Class 1 European Council Batch no Lot no Directive MDD 93 42 EEC on medical devices Intended use Mole has been developed for use when x raying bed bound users Intended enviroment Acute care Practical handling Positioning The transparent side of the device should face the user The assistant loosens the draw sheet and grasps it tightly Position the Mole e g for x ray of the thorax diagonally at the shoulder from the head end in the direction of the opposite foot end corner The assistant pushes the Mole between the sheet and the drawsheet until he she feel
6. media etac com m xport ac Immedia A S geskowej 12 K 8700 Horsens ac immedia etac com www etac com exp 0 Og m m Etac Sverige AB Box 203 334 24 Anderstorp S Tel 46 371 58 73 00 Fax 46 371 58 73 90 info etac se www etac se Etac AS Pb 249 1501 Moss N Tel 47 815 69 469 Fax 47 69 27 09 11 hovedkontor etac no www etac no Etac A S Egeskowej 12 8700 Horsens DK Tel 45 79 68 58 33 Fax 45 75 685840 info etac dk www etac dk Etac GMBH Bahnhofstra e 131 45770 Marl D Tel 49 236 598 710 Fax 49 236 598 6115 info etac de www etac de Etac Holland BV Fluorietweg 16a 1812RR Alkmaar NL Tel 31 72 547 04 39 Fax 31 72 547 13 05 info holland etac com www etac com R82 UK Ltd Unit D4A Coombswood Business Park East Coombswood Way Halesowen West Midlands B62 8BH UK Tel 0121 561 2222 Fax 0121 559 5437 R82uk r82 com www r82 co uk Snug Seat Inc 12801 E Independence Blvd PO Box 1739 Matthews NC 28106 US Tel 1 800 336 7684 Fax 704 882 0751 information snugseat com wwvw snugseat com eetac Creating possibilities
7. s Use Place the x ray cassette inside the glide bag supplied with the Mole The assistant separates the two parts slightly and using carpus helps push the glide bag with the x ray cassette under the user between the two parts of the Mole The corner straps on the bag are at the front edge Alternative method of positioning the Mole Assistant A grasps the draw sheet and pulls it taut Then assistant B grasps the draw sheet from the opposite side pulls it taut and pushes the Mole with the glide bag frame and x ray cassette right in under the user between the sheet and draw sheet at the users hip using weight transference If necessary the position of the x ray cassette and Mole can be adjusted using the straps resistance The assistant then turns the Mole so that it is perpendicu lar to the user The assistant grasps the draw sheet with both hands and pushes Mole in under the users hip thigh using weight transference When the x rays have been taken the glide bag and X ray cassette can be removed and replaced with a new cassette if more x rays are required After all x rays have been taken the Mole glide bag and x ray cassette can be pulled out together If the users hip is to be x rayed the Mole must be po sitioned diagonally at the hip from the foot end in the direction of the opposite corner bedhead Otherwise the process is the same as described above NB It is an advantage to position the draw sheet from shoul

Download Pdf Manuals

image

Related Search

Mole mole moleskine molex mole rat molecule mole food mole sauce molex connectors mole definition molecular geometry moleskine notebook mole poblano mole removal molecular formula molecular geometry chart mole cricket molecular weight molecule definition mole verde molester molecule 01 mole traps molecular sieve molecular cell molecular therapy