1. Mozart USER MANUAL PRELIMINARY TABLE OF CONTENTS ELANTRO UTN danos 3 o UI a ae a oe 3 UNPACKING INSTRUCTIONS 3 POWER REOUIREMENTS kink 3 SAFETY INSTRUCTIONS it 3 FUSE REPLACEMENT PSU yapa tidad 4 MOUNTING RIGGING 10 WAY PSU 4 5 DAA ios 5 DMX CONNECTOR CONFIGURATION FOR MOZART 10 WAY 5 nana 5 SETTING UPA DMX SN odia 6 ENTRE EN a 7 3 OPERATING INSTRU GC THON Scotia sii 7 INTERNAL ADDRESS di EE edn AR 8 A o A A A A MA NA IA A a AA nota 10 TEO ER RA A EN AA A A OI 10 APPENDIX ui dns 11 BASICS OF DMX CONTROL ii ee ea dau dai i 11 GENERAL MAINTENANCE di 11 EMITED VVARRANTY narices 12 RETURN RODECURE soria A A EOR O AA RE MO 12 MOZART FIXTURE TECHNICAL SPECIFICATIONS anni 13 MOZART 10 WAY PSU TECHNICAL SPECIFICATIONS kN 14 CONTACT INFORMATION ati 15 Solaris Mozart user manual version 1 8 031715 PRELIMINARY 1 Introduction PRODUCT OVERVIEW The Solaris LED Mozart is an extremely versatile and creative pixel mapping and decorative lighting tool that can be placed
2. x m P d j Solaris Mozart user manual version 1 8 031715 PRELIMINARY 13 MOZART 210 10 way PSU TECHNICAL SPECIFICATION DIMENSIONS WEIGHT DODI A a oooO O O 8 75 in 222 mm ll 7 25 in 186 mm eU Tu O 3 in 76 mm A T 5 lb 2 3 kg POWER A e Pe o A 100 240V AC power IN connector aaa user specified Power consumption e aaa 200W max with 10 Mozarts DMX power OUT connector e nena Amphenol Sensor M12 DO oje OUTE arroces AEA E 24V THERMAL Maximum ambient OS O ocu et ot 440 Minimum ambient temperature ii da da ke ea i v Va Din 20 C A Conventional o up to IP66 CONTROL amp PROGRAMMING o i E ee E E DMX 512 with RDM DUDAS RETE 3 12 48 IDU beer koke dora dad ka dka aka locking 5 pin XLR male socket DMX output for further linking locking 5 pin XLR female socket DMX output for Mozart Amphenol Sensor M12 DMX output for Mozart 10 max 10 WAY PSU inches mm a gt Te d 1 I s 163 144 o o 4 gi 4 gt
3. 2 conductor twisted pair plus a shield Max capacitance between conductors 30 Max capacitance between conductor and shield 55 pF ft Max resistance of 20 ohms 1000 ft Nominal impedance 100 140 ohms Cabling must have a male XLR connector on one end and a female XLR connector on the other end DMX CONNECTOR CONFIGURATION FOR MOZART 10 way PSU 1 SHIELD OUTPUT Termination reduces signal errors To avoid signal transmission problems and interference it is always advisable to connect a DMX signal terminator Resistance 120 ohm 1 4w between pin 2 OMX and pin 3 DMX of the last fixture Do not allow contact between the common and the fixture s chassis ground Grounding the common can cause a ground loop and your fixture may perform erratically Test cables with an ohm meter to verify correct polarity and to make sure the pins are not grounded or shorted to the shield or each other Solaris Mozart user manual version 1 8 031715 PRELIMINARY SETTING UP A DMX SERIAL LINK 1 Connect the male 5 pin connector side of the DMX cable to the output female 5 pin connector of the DMX console 2 Connect the opposite end of the cable female to the input connector of the Mozart PSU consisting of a male 5 pin connector 3 Proceed to connect from the PSU output as stated above to the input of the following PSU and so on 4 Continue linking until the last fixture is conected in your DMX chain
4. 4 Appendix BASICS OF DMX CONTROL There are 512 channels in a DMX 512 connection Channels may be assigned in any manner A fixture capable of receiving DMX 512 will reguire one or a number of seguential channels The user must assign a starting address on the fixture that indicates the first channel reserved in the lighting console There are many different types of DMX controllable fixtures and they all may vary in the total number of channels reguired Choosing a start address should be planned in advance Channels should never overlap If they do this will result in erratic operation of the overlapping fixtures You can however control multiple fixtures of the same type using the same starting address as long as the intended result is that of unison movement or operation In other words the fixtures will be slaved together and all will respond identically DMX fixtures are often designed to receive and transmit data through a DMX daisy chain A DMX daisy chain is where the DMX OUT of one fixture connects to the DMX IN of the next fixture The order in which the fixtures are connected is not important and has no effect on how a lighting console communicates to each fixture Use an order that provides for the easiest and most direct cabling Connect fixtures using shielded two conductor twisted pair cable such as ProPlex DMX with 5 pin XLR male to female connectors The shield ground is pin 1 while pin 2 is Data Negative D and pin 3 is Data
5. FIXTURE LINKING Mozart PSU continiue J linking owitchlratt ENS 00000000 2 0 0 0 0 6 0 8 0 0 0 0 0 0 0 0 SwitchCraft owitehlratt ENS aun 3 5 0 B i O i npananona Bu Lal Bu 0 0 B ooo up to 10 Mozart up to 10 Mozart fixtures fixtures Solaris Mozart user manual version 1 8 031715 PRELIMINARY 3 Operating instructions PIXEL MAP Mozart consists out of 64 RGB 1 chip engines which are located in 8 rows and 8 columns There are 3 control modes for Solaris Mozart fixtures 1 As 1 pixel unit 3 channel mode 2 As 4 pixel unit 12 channel mode 3 As 16 pixel unit 48 channel mode You can only change these modes using the RDM protocol and an RDM enabled controller 1 pixel 3CN e RDM Mode 1 e RDM Mode 2 4 pixel 1 2CHh e RDM Mode 3 16 pixel 40Ch Solaris Mozart user manual version 1 8 031715 PRELIMINARY INTERNAL ADDRESS SET The Mozart 10 way power supply must be addressed via RDM To set the address for Mozart fixtures first set the starting address for the Mozart 10 way powersupply To set the fixture address of Mozart fixtures 1 10 follow these steps Press and hold lt Address set gt button located at the back of the Mozart The current internal addressing number will appear 1 10 To change this number press lt Address set gt button The next addressing number
6. be returned in the original factory box and packing POWER REQUIREMENTS Before powering the unit make sure the line voltage is within the range of accepted voltages This fixture accommodates 100 240VAC 50 60Hz All fixtures must be powered directly from a switched circuit and cannot be operated with a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 100 switch When powered up Solaris LED performs a preprogrammed internal test On initial power up the factory default DMX address appears on the display screen and Solaris LED is ready for operation After initial power up the last saved DMX address will appear SAFETY INSTRUCTIONS Please read these instructions carefully This user guide contains important information about the installation usage and maintenance of this product e Please keep this User Guide for future reference If unit is sold to another user make sure they also receive this instruction booklet Solaris Mozart user manual version 1 8 031715 PRELIMINARY e Ensure fixture is connected to proper voltage and that line voltage is not higher than that stated on the fixture e Make sure there are no flammable materials close to the unit while operating e Always disconnect from the power source before servicing or fuse replacement Always use the fuse specified in this manual e Always use a safety cable when hanging fixture overhead e Maximum ambi
7. B 66 B R 2 7 R G 7 3 B R G G B B 1 73 R 2 G 74 G 5 B 75 B R 76 E 77 6 B 78 R 3 79 R G 1 80 G 7 81 B R R a 8 E B R 85 R i 87 B R 88 R a 4 6 80 B R R a 5 G 1 B B R R 6 G 2 B continue di necessary Solaris Mozart user manual version 1 8 031715 PRELIMINARY RDM Using RDM you also have an option to locate the device This will force selected Mozart to strobe its seguence number in white SENSORS Mozart has 3 sensors e Temperature sensor e Bus current sensor e Main voltage sensor Bus current and main voltage values can be seen only using RDM compliant lighting control device for example ProPlex MasterFade To see current temperature of Mozart press Address set button located at the back of fixture If Mozarts temperature is below or equal 40 104 F one green pixel 4 LEDs will appear as shown Mozart s temperature is indicated by the number of illuminated pixels i e one pixel equals 2 5 C increase In addition as Mozart s temperature increases more red pixels are illuminated At 60 C 140 F the fixture is prompted to slowly decrease the LEDs output intensity to reduce the temperature of fixture For example the diagram below shows the current temperature of a Mozart that is 60 40 base pixel and 8 additional pixels Solaris Mozart user manual version 1 8 031715 PRELIMINARY 10
8. almost anywhere Blazing fast 38 400Hz with Cree LEDSs Mozarts are ideal for high speed photography and video Modes include 1 4 or 16 pixels 3 to 48 DMX channels per fixture The 10 way power supply in a rugged ProPlex Mini enclosure is designed for portable use or truss mounting with yoke included Coming soon is the 40 way 2U RackMount power supply which supports DMX RDM AriNet and SACN protocols It features a large front panel touchscreen and a dedicated PC configuration utility Great for low weight load bearing structures and surfaces Approx 11 000 NITS Brighter than nearly all outdoor LED walls Rain and dust resistant IP65 enclosure use in all environments Ultra high refresh rate 38 400Hz Great for high speed photography and videography Single cable simple power data connections daisy chain or split location flexibility Extremely compact and lightweight 4 7 x 43 7 inches Only 1 1 4 bb Easy remote addressing and mode switching via RDM UNPACKING INSTRUCTIONS Upon receipt of the fixture carefully unpack the carton and check the contents to ensure that all parts are present and in good condition Notify the shipper immediately and retain packing material for inspection if any parts appear to be damaged from shipping or if the carton itself shows signs of mishandling Save the carton and all packing materials In the event that a fixture must be returned to the factory it is important that the fixture
9. gt 8 1 72 436 D L4 Solaris Mozart user manual version 1 8 031715 PRELIMINARY 14 CONTACT INFORMATION GENERAL INFORMATION 24 7 TECHNICAL SUPPORT TMB US Phone Fax UK Phone Fax e mall web TMB US Canada Toll free UK International e mail 41 818 899 8818 41 818 899 8813 44 0 20 8574 9700 44 0 20 8574 9701 tmb info tmb com www tmb com 1 877 TMB DUDE 1 877 862 3833 0800 652 5418 1 818 794 1286 techsupport tmb com Solaris Mozart user manual version 1 8 031715 PRELIMINARY 15
10. least every 30 to 60 days Solaris Mozart user manual version 1 8 031715 PRELIMINARY 11 LIMITED WARRANTY Solaris LED fixtures the Product are warranted by TMB against defective materials or workmanship for a period of two 2 years from the date of original sale by TMB TMB s warranty shall be restricted to the repair or replacement of any part that proves to be defective and for which a claim is submitted to TMB before the expiration of the applicable warranty periods This Limited Warranty 15 void if the defects of the Product are the result of e Opening the casing repair or adjustment by anyone other than TMB or persons specifically authorized by TMB e Accident physical abuse mishandling or misapplication of the product e Damage due to lightning earthquake flood terrorism war act of God TMB will not assume responsibility for any labor expended or materials used to replace and or repair the Product without TMB s prior written authorization Any repair of the Product in the field and any associated labor charges must be authorized in advance by TMB Freight costs on warranty repairs are split 50 50 Customer pays to ship defective product to TMB TMB pays to ship repaired product ground freight back to Customer This warranty DOES NOT cover consequential damages or costs of any kind A Return Merchandise Authorization Number must be obtained from TMB prior to return of any defective merchandise for wa
11. positive D Pins 4 and 5 are not used according to the DMX 512 standard GENERAL MAINTENANCE To maintain optimum performance and minimize wear fixtures should be cleaned frequently Usage and environment are contributing factors in determining frequency As a general rule fixtures should be cleaned at least twice a month Dust build up reduces light output performance and can cause overheating This can lead to reduced lamp life and increased mechanical wear Be sure to disconnect power to the fixture before conducting maintenance Unplug fixture from power Use a vacuum or air compressor and a soft brush to remove dust collected on external vents and internal components Clean all glass when the fixture is cold with a mild solution of glass cleaner or Isopropyl Alcohol and a soft lint free cotton cloth or lens tissue Apply solution to the cloth or tissue and drag dirt and grime to the outside of the lens Gently polish optical surfaces until they are free of haze and lint The cleaning of internal and external optical lenses and or mirrors must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at
12. will appear Repeat until the desired fixture number is shown on the tile Rendering of numbers from 1 10 shown on Mozarts LEDs 1 E 4 5 7 E amp E 98 8 U od a 4 4 x E a s s j E E 1 a e i J E a 9 6 z E z k amp umom fj Sa o m umom o E a ma z o nom E J 6 7 8 9 10 fi 7 ja S 4 E E EFTE te 1 ow i 8 9 amp i E se SC E E E CA oa mo a e m b i e a E E E om E E ies E a 9 mom mo m 8 E na ka Solaris Mozart user manual version 1 8 031715 PRELIMINARY Using starting address of DMX 1 on the 10 way PSU this chart FIXTURE ID FIXTURE ID CH CH 1 JR 49 R is an example of the Mozart 2 Js 1 50 G 7 fixture addresses 3 B 51 4 R 5 G 2 G 6 IB 7 R 1 58 gt 3 56 G 9 B 57 B R R G a 10 B B R 61 R 62 G 1 63 B R 64 65 G 2
13. NA IE ME 1 8 in 45 mm e PE GO 4 7 in 119 mm Wen NE e EM ARE AE AE AE IAE NAMENE 1 25 lb 565g POWER e T 24V DC Power CONSUMPIUION TREE 20W full load DMX power connectors Amphenol Sensor M12 LIGHT SOURCE 64 Cree LMC E LEDs Selle s A A AE O A AA A EI AA A ARE AP A PERE ARE A ER VIA PEU ENIM RGB Beam STENO a a o A A Gs ea a a a 120 38 400Hz Average Color Wavelenght cccccccccccoconncconnnccononononononnnonononannnnnnnnnnnononnncnnnnnnnonenannnnnnnnnns red 625 nm green 530 nm blue 460 nm THERMAL Max ambient tempelralUl s s kcal a ne ia 40 C Min ambient teMperature ccccoocccccccncccccnnoconnnoconnnonnnnnnnnnnonnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnarnnnnnninnnnos 20C Sep A A Conventional A 65 CONTROL 8 PROGRAMMING eon m P DMX 512A with RDM Sol dimniming CONTO MM 16bi or 8 bitt Ena ee e E E E AE LJ AE A O AR A OMAN HA VEMO UME 1 4 16 DMX Channels M 3 12 48 based on selected pixel mode Bss do oe WENN NN A 16 bit DMX power connectors Amphenol Sensor M12 1 22 31mm 2 28 58mm 1 E E
14. ent temperature Ta is 40 104 F Do not operate fixture at temperatures above this rating e event of a serious operating problem stop using the unit immediately Repairs must be carried out by trained authroized personnel Conact the nearest authorized technical assistance center Only OEM spare parts should be used Do not connect the device to a dimmer pack Make sure power cord 15 never crimped or damaged Never disconnect power cord by pulling or tugging on the cord Avoid direct eye exposure to the light source during operation Caution There are no user serviceable parts inside the unit Do not open the housing or attempt any repairs yourself In the unlikely event your unit may require service please contact your distributor Disconnect the power cord before replacing a fuse and always replace with the same type fuse FUSE REPLACEMENT The Mozart 10 way PSU uses 6 250V slow blow 5x20mm 0 2x0 8 in fuse Mozart fixtures have fuse To replace fuse 1 With a screwdriver turn the fuse cap counter clockwise to remove fuse cap with fuse 2 Replace fuse attached to fuse cap Reinsert fuse cap with new fuse and tighten clockwise MOUNTING RIGGING MZ10 PSU 10 way MINI ENCLOSURE Orientation The Mozart MZ10 PSU 10 way may be mounted on truss or pipe in any position using the yoke supplied with the unit Always make sure there is adequate room for ventilation Rigging Always consult a ce
15. rranty or non warranty repair For all repairs please contact TMB Tech Support Repair using the contact information below or email TechSupportRepairNA tmb com 527 Park Ave San Fernando CA 91340 Tel 1 818 899 8818 Fax 1 818 899 8813 tmb info tmb com www tmb com RETURN PROCEDURE Returned merchandise must be sent prepaid and in the original packing call tags will not be issued Package must be clearly labeled with a Return Merchandise Authorization Number RMA Products returned without an RMA will be refused Please contact TMB and request RMA prior to shipping the fixture Be prepared to provide the model number serial number and a brief description of the cause for the return Be sure to properly pack fixture any shipping damage resulting from inadequate packaging is the customer s responsibility TMB reserves the right to use its own discretion to repair or replace product s As a suggestion proper UPS packing or double boxing is always a safe method to use Note If you are given an RMA please include the following information on a piece of paper inside the box 1 Your name 2 Your address 3 Your phone number 4 The RMA 5 A brief description of the symptoms Solaris Mozart user manual version 1 8 031715 PRELIMINARY 2125 MOZART FIXTURE TECHNICAL SPECIFICATION DIMENSIONS WEIGHT o E POR II 4 7 in 119 mm PAROI g ENEE ee EE oe A A Mi A A A
16. rtified rigging engineer before suspending any fixture overhead s Use ProBurger couplers or equivalent C or O type clamps for attaching to truss After EM ow establishing the desired position retighten both knobs e Always use safety cables e When selecting installation location consider routine maintenance e Never mount Mini enclosure where it will be exposed to moisture high humidity extreme temperatures or restricted ventilation Solaris Mozart user manual version 1 8 031715 PRELIMINARY 2 Setup A DMX data link is needed to run light shows of one or more fixtures using a DMX 512 lighting console The combined number of channels reguired by all of the fixtures on the DMX data link will determine the number of fixtures the DMX data link can support Important Fixtures on a DMX data link must be daisy chained in one single line To comply with the ElA 485 standard no more than 32 devices should be connected on one data link Connecting more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal Maximum recommended DMX data link distance between fixtures 300 meters 984 ft DMX DATA CABLE Use ProPlex DMX cable or equivalent which meets the specifications for EIA RS 485 applications Standard microphone cables cannot transmit DMX data reliably over long distances The data cable must have the following characteristics