Home

5804BD Bi-Directional Key

image

Contents

1. Previous menu N8209V1 04 97 5804BD ADEMCO INSTALLATION INSTRUCTIONS General Information The 5804BD is a four button wireless key that permits an alarm system to be controlled remotely It is a two way device which means that it can send a command to the alarm system such as to arm or disarm as well as receive status back from the control Status is indicated by two bi color status LEDs and a piezoelectric sounder Each button can be programmed for any zone response type by using the alarm system s transmitter learn mode Typical use is for arming disarming panic and output relay operation The 5804BD must be used in conjunction with a 5800TM Transmitter Module and 5881 RF Receiver The unit is powered by 2 replaceable Lithium batteries designed to provide up to 2 years of life see To Install Replace Batteries for more information Green Yellow LED F Note Place the 5881 receiver and va PD M h y Loop ASSIANMENES mayre K oe Mp T N the 5800TM transmitter module in a high centrally located area for best reception The 5800TM module must be located between 1 and 2 feet from the receiver e Button A gt Loop 3 e Button B gt Loop 2 Button D e Button C gt Loop 4 C Button D gt Loop 1 5804BD Front View Belt Clip To Remove or Insert the Unit from Belt Clip To Install Replace Batteries 1 Remove the screw from the back case Remove case back by
2. each button during programming see loop assignments on previous page Button C If you choose not to use the C button you must do the following to avoid a Check condition when the button is accidentally pressed 1 Assign this button to a zone see Assign a Button to a Zone 2 After the serial number has been programmed re enter Zone Programming for that zone 3 Atthe Zone Type prompt enter 00 and press a On Via 30 controls and below the system will ask whether you want to permanently delete that zone Enter 0 No This will cause the system to retain the serial number but render the button inactive b On Vista 40 and above continue to press until you see the Enter zone No prompt again At this point Press 00 and Then press 99 to exit program mode Arm Disarm Button If a button assigned to a zone type 20 Arm Stay 21 Arm Away and 22 Disarm you must do the following On Vista 40 50 50P 100 and up On Via 30 Vista 20 and below You must assign a user to the button in order for it to operate You do not have to assign a user to the button The panel will To assign a user number to the Arm Disarm button report the zone number as the user number to the central station 1 Enter 4 digit User Code 8 User 4 digit new User Code 2 Answer Yes or No on the Open Close Report question 3 Answer Yes on the RF Button question 4 Enter the zone assigned to
3. k A Enter HID mode Enter HID 17 Press To accept entry press HID will be shown by Press A B C buttons amp release A button D button flashing LEDs Then until LEDs flash once press amp release exit HID mode B button 7 times To View the House ID a Enter House ID mode as described in step 1 above b Depress the D button to view c The unit displays the stored number as described in step 4 above d The unit will then exit House ID mode a beep will be heard Programming a House ID in the Alarm Control 1 On Vista 40 50 50P 100 and up use Device Programming mode to enable the RF receiver and enter the House ID number 2 On Via 30 Vista 20 and below go to field 24 and enter the House ID number Programming the Buttons Each 5804BD is assigned a unique serial number during manufacture Each button on the unit also has a unique loop number that must be programmed into the alarm control during installation Assign each button to an individual zone number and program the Input Type as BR Button Type RF entry of 5 in the control s Zone Programming mode Then input the serial number by one of the following methods 1 learn the serial number of the device into the system as described in the alarm control s Installation Instructions 2 enter the serial number manually through the keypad 3 serial number through VLINK downloading software Be sure to include the loop number of
4. DERAL COMMUNICATIONS COMMISSION FCC Part 15 STATEMENT This equipment has been tested to FCC requirements and has been found acceptable for use The FCC requires the following statement for your information This equipment generates and uses radio frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio and television reception It has been type tested and found to comply with the limits for a Class B computing device in accordance with the specifications in Part 15 of FCC Rules which are designed to provide reasonable protection against such interference in a residential installation However there is no guarantee that interference will not occur in a particular installation If this equipment does cause interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures If using an indoor antenna have a quality outdoor antenna installed Reorient the receiving antenna until interference is reduced or eliminated Move the radio or television receiver away from the receiver control Move the antenna leads away from any wire runs to the receiver control Plug the receiver control into a different outlet so that it and the radio or television receiver are on different branch circuits If necessary the user should cons
5. R IF SELLER IS HELD LIABLE WHETHER DIRECTLY OR INDIRECTLY FOR ANY LOSS OR DAMAGE ARISING UNDER THIS LIMITED WARRANTY OR OTHERWISE REGARDLESS OF CAUSE OR ORIGIN SELLER S MAXIMUM LIABILITY SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE OF THE PRODUCT WHICH SHALL BE THE COMPLETE AND EXCLUSIVE REMEDY AGAINST SELLER This warranty replaces any previous warranties and is the only warranty made by Seller on this product No increase or alteration written or verbal of the obligations of this Limited Warranty is authorized ALARM DEVICE MANUFACTURING CO AD E Mi C O A DIVISION OF PITTWAY CORPORATION 165 Eileen Way Syosset NY 11791 COPYRIGHT 1997 PITTWAY CORPORATION N8209V1 04 97
6. ation under this Limited Warranty or otherwise if the product is altered or improperly repaired or serviced by anyone other than Ademco factory service For warranty service return product transportation prepaid to Ademco Factory Service 165 Eileen Way Syosset New York 11791 THERE ARE NO WARRANTIES EXPRESS OR IMPLIED OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER S OWN NEGLIGENCE OR FAULT Seller does not represent that the products it sells may not be compromised or circumvented that the products will prevent any personal injury or property loss by burglary robbery fire or otherwise or that the products will in all cases provide adequate warning or protection Customer understands that a properly installed and maintained alarm may only reduce the risk of a burglary robbery fire or other events occurring without providing an alarm but it is not insurance or a guarantee that such will not occur or that there will be no personal injury or property loss as a result CONSEQUENTLY SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY PROPERTY DAMAGE OR OTHER LOSS BASED ON A CLAIM THE PRODUCT FAILED TO GIVE WARNING HOWEVE
7. the Arm Disarm button 5 Keypad shows the summary of user information on its display 6 Test Arm Disarm button to make sure it operates correctly Operating the Buttons To Activate a Button To activate programmed function on a button press and hold the button down until the yellow LED flashes 2 beeps will be heard and then release it To Request System Status Since the 5804BD is a two way device users can check the system status before arming or disarming their system To check system status press and release any button momentarily The yellow LED will flash after you release the button 1 beep will be heard After a second or two the 5804BD will display the system status information using a combination of LED and sounder activity see the System Status Indications Table below If 58304BD does not receive system status information from the panel for approximately five seconds it will generate a long 1 second beep and shut itself down It will also shut itself down if there is no button activity within five seconds of receiving a status update This device may not receive the system status properly if it operates within a few feet of the 5881 RF receiver System Status Indications Table On Steady 2 Beeps Armed Away or Maximum On Steady 3 Beeps Armed Stay or Instant Flashing Pulsing Fire Alarm in progress Flashing Steady Armed Burglary Alarm in progress Flashing Silent Alarm Memory Flashing Silent Disarmed Not Ready
8. to Arm Indicates RF transmission In Enter House ID Mode Green Flashing Pulsing System in Trouble Flashing Silent System Not Ready Multiple Button Operations A C Button Pai B D Button Pair The 5804BD can generate the same responses as Bi PN A keypad panic key pairs of and 1 by depressing A C and B D button pairs respectively You must depress the button pair for at least two seconds for the 5804BD to recognize the button pair command These button pairs will allow the user to activate panic fire and medical alarms depending on control panel programming Low Battery Indication When the unit goes into a Low Battery condition the yellow LED will not flash when a button is pressed Change both batteries immediately Refer to instructions in To Install Replace Batteries paragraph on first page Specifications Physical Battery Maxell CR2430 or Duracell DL2430 Belt Clip 4 1H x 2 2 W x 0 8 D Transmitter 3 9 H x2 0 W x 0 69 D REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL WITH WHICH THIS DEVICE IS USED FOR LIMITATIONS OF THE ENTIRE ALARM SYSTEM FCC STATEMENT This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC ID CFS8DL5804BD FE
9. ult the dealer or an experienced radio television technician for additional suggestions The user or installer may find the following booklet prepared by the Federal Communications Commission helpful Interference Handbook This booklet is available from the U S Government Printing Office Washington DC 20402 The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User s Manual Unauthorized changes or modifications could void the user s authority to operate the equipment ADEMCO LIMITED WARRANTY Alarm Device Manufacturing Company a Division of Pittway Corporation and its divisions subsidiaries and affiliates Seller 165 Eileen Way Syosset New York 11791 warrants its products to be in conformance with its own plans and specifications and to be free from defects in materials and workmanship under normal use and service for 24 months from the date stamp control on the product or for products not having an Ademco date stamp for 12 months from date of original purchase unless the installation instructions or catalog sets forth a shorter period in which case the shorter period shall apply Seller s obligation shall be limited to repairing or replacing at its option free of charge for materials or labor any product which is proved not in compliance with Seller s specifications or proves defective in materials or workmanship under normal use and service Seller shall have no oblig
10. using the blade of a small screwdriver to pry open 3 Place batteries in case back locations see diagram Use CR2430 or DL2430 Lithium battery only 4 Close the case by snapping case front and back together 5 Replace the screw to secure the case Improperly installing the batteries will cause damage to the batteries Programming the 5804BD House ID You need to program a House ID number into the unit before you can to use it to display the system status The House ID number must be same as the one used in the alarm control The House ID must be in the range of 01 to 31 The default in the 5804BD is 10 To Enter a House ID 1 Enter House ID mode by pressing the A B and C buttons at the same time until the Red and Green LEDs alternate flashing 2 Enter the House ID number by using the A button to enter the 10 s digit and the B button to enter the 1 s digit Note If the entry is out of range greater than 31 the unit will generate a long beep and discard the entry 3 Accept the entry by pressing the D button 4 The unit displays the stored number by flashing the left LED for the 10 s digit and flashing the right LED for the 1 s digit for example for House ID 21 the left LED will flash twice the right LED will flash once 5 The unit will then exit the House ID mode a beep will be heard Example To enter House ID 17 into the unit O f OY OL A y A